Search Results

Search found 1116 results on 45 pages for 'nic dk'.

Page 10/45 | < Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >

  • Where to get the network NIC's firmware rtl_nic/rtl8105e-1.fw?

    - by Kyrol
    Im installing Debian testing version wheezy on my Asus X53Sc with Intel Centrino Wireless-N 100. Im having a problem with my wifi connection. When I try to connect to internet with the wireless connection, an error occurs: Possible missing firmware /lib/firmware/rtl_nic/rtl8105e-1.fw for module r8169. I installed successfully the iwlwifi-100-5.ucode, but now I have this error. Any ideas or suggestions to resolve the problem ?

    Read the article

  • How fast can a Windows 2008 CIFS client write to SAMBA server using 10Gb NIC?

    - by one_bsd_guy
    We are experiencing a performance problem using Windows 2008 CIFS client. We have a FreeNAS server that delivers 1.3GB/s on ZFS write. We have 10Gb network connecting NAS server and CIFS clients. Using two Linux CIFS clients, we can get around 1.2GB/s. But windows 2008 clients can only give us 400MB/s. Is that the best a Windows 2008 client can deliver or we do have a poorly configured Windows client? Much appreciated.

    Read the article

  • unexplainable packet drops with 5 ethernet NICs and low traffic on Ubuntu

    - by jon
    I'm stuck on problem where my machine started to drops packets with no sign of ANY system load or high interrupt usage after an upgrade to Ubuntu 12.04. My server is a network monitoring sensor, running Ubuntu LTS 12.04, it passively collects packets from 5 interfaces doing network intrusion type stuff. Before the upgrade I managed to collect 200+GB of packets a day while writing them to disk with around 0% packet loss depending on the day with the help of CPU affinity and NIC IRQ to CPU bindings. Now I lose a great deal of packets with none of my applications running and at very low PPS rate which a modern workstation NIC would have no trouble with. Specs: x64 Xeon 4 cores 3.2 Ghz 16 GB RAM NICs: 5 Intel Pro NICs using the e1000 driver (NAPI). [1] eth0 and eth1 are integrated NICs (in the motherboard) There are 2 other PCI-X network cards, each with 2 Ethernet ports. 3 of the interfaces are running at Gigabit Ethernet, the others are not because they're attached to hubs. Specs: [2] http://support.dell.com/support/edocs/systems/pe2850/en/ug/t1390aa.htm uptime 17:36:00 up 1:43, 2 users, load average: 0.00, 0.01, 0.05 # uname -a Linux nms 3.2.0-29-generic #46-Ubuntu SMP Fri Jul 27 17:03:23 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux I also have the CPU governor set to performance mode and irqbalance off. The problem still occurs with them on. # lspci -t -vv -[0000:00]-+-00.0 Intel Corporation E7520 Memory Controller Hub +-02.0-[01-03]--+-00.0-[02]----0e.0 Dell PowerEdge Expandable RAID controller 4 | \-00.2-[03]-- +-04.0-[04]-- +-05.0-[05-07]--+-00.0-[06]----07.0 Intel Corporation 82541GI Gigabit Ethernet Controller | \-00.2-[07]----08.0 Intel Corporation 82541GI Gigabit Ethernet Controller +-06.0-[08-0a]--+-00.0-[09]--+-04.0 Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) | | \-04.1 Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) | \-00.2-[0a]--+-02.0 Digium, Inc. Wildcard TE210P/TE212P dual-span T1/E1/J1 card 3.3V | +-03.0 Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) | \-03.1 Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) +-1d.0 Intel Corporation 82801EB/ER (ICH5/ICH5R) USB UHCI Controller #1 +-1d.1 Intel Corporation 82801EB/ER (ICH5/ICH5R) USB UHCI Controller #2 +-1d.2 Intel Corporation 82801EB/ER (ICH5/ICH5R) USB UHCI Controller #3 +-1d.7 Intel Corporation 82801EB/ER (ICH5/ICH5R) USB2 EHCI Controller +-1e.0-[0b]----0d.0 Advanced Micro Devices [AMD] nee ATI RV100 QY [Radeon 7000/VE] +-1f.0 Intel Corporation 82801EB/ER (ICH5/ICH5R) LPC Interface Bridge \-1f.1 Intel Corporation 82801EB/ER (ICH5/ICH5R) IDE Controller I believe the NIC nor the NIC drivers are dropping the packets because ethtool reports 0 under rx_missed_errors and rx_no_buffer_count for each interface. On the old system, if it couldn't keep up this is where the drops would be. I drop packets on multiple interfaces just about every second, usually in small increments of 2-4. I tried all these sysctl values, I'm currently using the uncommented ones. # cat /etc/sysctl.conf # high net.core.netdev_max_backlog = 3000000 net.core.rmem_max = 16000000 net.core.rmem_default = 8000000 # defaults #net.core.netdev_max_backlog = 1000 #net.core.rmem_max = 131071 #net.core.rmem_default = 163480 # moderate #net.core.netdev_max_backlog = 10000 #net.core.rmem_max = 33554432 #net.core.rmem_default = 33554432 Here's an example of an interface stats report with ethtool. They are all the same, nothing is out of the ordinary ( I think ), so I'm only going to show one: ethtool -S eth2 NIC statistics: rx_packets: 7498 tx_packets: 0 rx_bytes: 2722585 tx_bytes: 0 rx_broadcast: 327 tx_broadcast: 0 rx_multicast: 1504 tx_multicast: 0 rx_errors: 0 tx_errors: 0 tx_dropped: 0 multicast: 1504 collisions: 0 rx_length_errors: 0 rx_over_errors: 0 rx_crc_errors: 0 rx_frame_errors: 0 rx_no_buffer_count: 0 rx_missed_errors: 0 tx_aborted_errors: 0 tx_carrier_errors: 0 tx_fifo_errors: 0 tx_heartbeat_errors: 0 tx_window_errors: 0 tx_abort_late_coll: 0 tx_deferred_ok: 0 tx_single_coll_ok: 0 tx_multi_coll_ok: 0 tx_timeout_count: 0 tx_restart_queue: 0 rx_long_length_errors: 0 rx_short_length_errors: 0 rx_align_errors: 0 tx_tcp_seg_good: 0 tx_tcp_seg_failed: 0 rx_flow_control_xon: 0 rx_flow_control_xoff: 0 tx_flow_control_xon: 0 tx_flow_control_xoff: 0 rx_long_byte_count: 2722585 rx_csum_offload_good: 0 rx_csum_offload_errors: 0 alloc_rx_buff_failed: 0 tx_smbus: 0 rx_smbus: 0 dropped_smbus: 01 # ifconfig eth0 Link encap:Ethernet HWaddr 00:11:43:e0:e2:8c UP BROADCAST RUNNING NOARP PROMISC ALLMULTI MULTICAST MTU:1500 Metric:1 RX packets:373348 errors:16 dropped:95 overruns:0 frame:16 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:356830572 (356.8 MB) TX bytes:0 (0.0 B) eth1 Link encap:Ethernet HWaddr 00:11:43:e0:e2:8d UP BROADCAST RUNNING NOARP PROMISC ALLMULTI MULTICAST MTU:1500 Metric:1 RX packets:13616 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:8690528 (8.6 MB) TX bytes:0 (0.0 B) eth2 Link encap:Ethernet HWaddr 00:04:23:e1:77:6a UP BROADCAST RUNNING NOARP PROMISC ALLMULTI MULTICAST MTU:1500 Metric:1 RX packets:7750 errors:0 dropped:471 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:2780935 (2.7 MB) TX bytes:0 (0.0 B) eth3 Link encap:Ethernet HWaddr 00:04:23:e1:77:6b UP BROADCAST RUNNING NOARP PROMISC ALLMULTI MULTICAST MTU:1500 Metric:1 RX packets:5112 errors:0 dropped:206 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:639472 (639.4 KB) TX bytes:0 (0.0 B) eth4 Link encap:Ethernet HWaddr 00:04:23:b6:35:6c UP BROADCAST RUNNING NOARP PROMISC ALLMULTI MULTICAST MTU:1500 Metric:1 RX packets:961467 errors:0 dropped:935 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:958561305 (958.5 MB) TX bytes:0 (0.0 B) eth5 Link encap:Ethernet HWaddr 00:04:23:b6:35:6d inet addr:192.168.1.6 Bcast:192.168.1.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:4264 errors:0 dropped:16 overruns:0 frame:0 TX packets:699 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:572228 (572.2 KB) TX bytes:124456 (124.4 KB) I tried the defaults, then started to play around with settings. I wasn't using any flow control and I increased the RxDescriptor count to 4096 before the upgrade as well without any problems. # cat /etc/modprobe.d/e1000.conf options e1000 XsumRX=0,0,0,0,0 RxDescriptors=4096,4096,4096,4096,4096 FlowControl=0,0,0,0,0 debug=16 Here's my network configuration file, I turned off checksumming and various offloading mechanisms along with setting CPU affinity with heavy use interfaces getting an entire CPU and light use interfaces sharing a CPU. I used these settings prior to the upgrade without problems. # cat /etc/network/interfaces # The loopback network interface auto lo iface lo inet loopback # The primary network interface auto eth0 iface eth0 inet manual pre-up /sbin/ethtool -G eth0 rx 4096 tx 0 pre-up /sbin/ethtool -K eth0 gro off gso off rx off pre-up /sbin/ethtool -A eth0 rx off autoneg off up ifconfig eth0 0.0.0.0 -arp promisc mtu 1500 allmulti txqueuelen 0 up post-up echo "4" > /proc/irq/48/smp_affinity down ifconfig eth0 down post-down /sbin/ethtool -G eth0 rx 256 tx 256 post-down /sbin/ethtool -K eth0 gro on gso on rx on post-down /sbin/ethtool -A eth0 rx on autoneg on auto eth1 iface eth1 inet manual pre-up /sbin/ethtool -G eth1 rx 4096 tx 0 pre-up /sbin/ethtool -K eth1 gro off gso off rx off pre-up /sbin/ethtool -A eth1 rx off autoneg off up ifconfig eth1 0.0.0.0 -arp promisc mtu 1500 allmulti txqueuelen 0 up post-up echo "4" > /proc/irq/49/smp_affinity down ifconfig eth1 down post-down /sbin/ethtool -G eth1 rx 256 tx 256 post-down /sbin/ethtool -K eth1 gro on gso on rx on post-down /sbin/ethtool -A eth1 rx on autoneg on auto eth2 iface eth2 inet manual pre-up /sbin/ethtool -G eth2 rx 4096 tx 0 pre-up /sbin/ethtool -K eth2 gro off gso off rx off pre-up /sbin/ethtool -A eth2 rx off autoneg off up ifconfig eth2 0.0.0.0 -arp promisc mtu 1500 allmulti txqueuelen 0 up post-up echo "1" > /proc/irq/82/smp_affinity down ifconfig eth2 down post-down /sbin/ethtool -G eth2 rx 256 tx 256 post-down /sbin/ethtool -K eth2 gro on gso on rx on post-down /sbin/ethtool -A eth2 rx on autoneg on auto eth3 iface eth3 inet manual pre-up /sbin/ethtool -G eth3 rx 4096 tx 0 pre-up /sbin/ethtool -K eth3 gro off gso off rx off pre-up /sbin/ethtool -A eth3 rx off autoneg off up ifconfig eth3 0.0.0.0 -arp promisc mtu 1500 allmulti txqueuelen 0 up post-up echo "2" > /proc/irq/83/smp_affinity down ifconfig eth3 down post-down /sbin/ethtool -G eth3 rx 256 tx 256 post-down /sbin/ethtool -K eth3 gro on gso on rx on post-down /sbin/ethtool -A eth3 rx on autoneg on auto eth4 iface eth4 inet manual pre-up /sbin/ethtool -G eth4 rx 4096 tx 0 pre-up /sbin/ethtool -K eth4 gro off gso off rx off pre-up /sbin/ethtool -A eth4 rx off autoneg off up ifconfig eth4 0.0.0.0 -arp promisc mtu 1500 allmulti txqueuelen 0 up post-up echo "4" > /proc/irq/77/smp_affinity down ifconfig eth4 down post-down /sbin/ethtool -G eth4 rx 256 tx 256 post-down /sbin/ethtool -K eth4 gro on gso on rx on post-down /sbin/ethtool -A eth4 rx on autoneg on auto eth5 iface eth5 inet static pre-up /etc/fw.conf address 192.168.1.1 netmask 255.255.255.0 broadcast 192.168.1.255 gateway 192.168.1.1 dns-nameservers 192.168.1.2 192.168.1.3 up ifconfig eth5 up post-up echo "8" > /proc/irq/77/smp_affinity down ifconfig eth5 down Here's a few examples of packet drops, i ran one after another, probabling totaling 3 or 4 seconds. You can see increases in the drops from the 1st and 3rd. This was a non-busy time, very little traffic. # awk '{ print $1,$5 }' /proc/net/dev Inter-| face drop eth3: 225 lo: 0 eth2: 505 eth1: 0 eth5: 17 eth0: 105 eth4: 1034 # awk '{ print $1,$5 }' /proc/net/dev Inter-| face drop eth3: 225 lo: 0 eth2: 507 eth1: 0 eth5: 17 eth0: 105 eth4: 1034 # awk '{ print $1,$5 }' /proc/net/dev Inter-| face drop eth3: 227 lo: 0 eth2: 512 eth1: 0 eth5: 17 eth0: 105 eth4: 1039 I tried the pci=noacpi options. With and without, it's the same. This is what my interrupt stats looked like before the upgrade, after, with ACPI on PCI it showed multiple NICs bound to an interrupt and shared with other devices such as USB drives which I didn't like so I think i'm going to keep it with ACPI off as it's easier to designate sole purpose interrupts. Is there any advantage I would have using the default i.e. ACPI w/ PCI. ? # cat /etc/default/grub | grep CMD_LINE GRUB_CMDLINE_LINUX_DEFAULT="ipv6.disable=1 noacpi pci=noacpi" GRUB_CMDLINE_LINUX="" # cat /proc/interrupts CPU0 CPU1 CPU2 CPU3 0: 45 0 0 16 IO-APIC-edge timer 1: 1 0 0 7936 IO-APIC-edge i8042 2: 0 0 0 0 XT-PIC-XT-PIC cascade 6: 0 0 0 3 IO-APIC-edge floppy 8: 0 0 0 1 IO-APIC-edge rtc0 9: 0 0 0 0 IO-APIC-edge acpi 12: 0 0 0 1809 IO-APIC-edge i8042 14: 1 0 0 4498 IO-APIC-edge ata_piix 15: 0 0 0 0 IO-APIC-edge ata_piix 16: 0 0 0 0 IO-APIC-fasteoi uhci_hcd:usb2 18: 0 0 0 1350 IO-APIC-fasteoi uhci_hcd:usb4, radeon 19: 0 0 0 0 IO-APIC-fasteoi uhci_hcd:usb3 23: 0 0 0 4099 IO-APIC-fasteoi ehci_hcd:usb1 38: 0 0 0 61963 IO-APIC-fasteoi megaraid 48: 0 0 1002319 4 IO-APIC-fasteoi eth0 49: 0 0 38772 3 IO-APIC-fasteoi eth1 77: 0 0 130076 432159 IO-APIC-fasteoi eth4 78: 0 0 0 23917 IO-APIC-fasteoi eth5 82: 1329033 0 0 4 IO-APIC-fasteoi eth2 83: 0 4886525 0 6 IO-APIC-fasteoi eth3 NMI: 5 6 4 5 Non-maskable interrupts LOC: 61409 57076 64257 114764 Local timer interrupts SPU: 0 0 0 0 Spurious interrupts IWI: 0 0 0 0 IRQ work interrupts RES: 17956 25333 13436 14789 Rescheduling interrupts CAL: 22436 607 539 478 Function call interrupts TLB: 1525 1458 4600 4151 TLB shootdowns TRM: 0 0 0 0 Thermal event interrupts THR: 0 0 0 0 Threshold APIC interrupts MCE: 0 0 0 0 Machine check exceptions MCP: 16 16 16 16 Machine check polls ERR: 0 MIS: 0 Here's sample output of vmstat, showing the system. Barebones system right now. root@nms:~# vmstat -S m 1 procs -----------memory---------- ---swap-- -----io---- -system-- ----cpu---- r b swpd free buff cache si so bi bo in cs us sy id wa 0 0 0 14992 192 1029 0 0 56 2 419 29 1 0 99 0 0 0 0 14992 192 1029 0 0 0 0 922 27 0 0 100 0 0 0 0 14991 192 1029 0 0 0 36 763 50 0 0 100 0 0 0 0 14991 192 1029 0 0 0 0 646 35 0 0 100 0 0 0 0 14991 192 1029 0 0 0 0 722 54 0 0 100 0 0 0 0 14991 192 1029 0 0 0 0 793 27 0 0 100 0 ^C Here's dmesg output. I can't figure out why my PCI-X slots are negotiated as PCI. The network cards are all PCI-X with the exception of the integrated NICs that came with the server. In the output below it looks as if eth3 and eth2 negotiated at PCI-X speeds rather than PCI:66Mhz. Wouldn't they all drop to PCI:66Mhz? If your integrated NICs are PCI, as labeled below (eth0,eth1), then wouldn't all devices on your bus speed drop down to that slower bus speed? If not, I still don't know why only one of my NICs ( each has two ethernet ports) is labeled as PCI-X in the output below. Does that mean it is running at PCI-X speeds are is it showing that it's capable? # dmesg | grep e1000 [ 3678.349337] e1000: Intel(R) PRO/1000 Network Driver - version 7.3.21-k8-NAPI [ 3678.349342] e1000: Copyright (c) 1999-2006 Intel Corporation. [ 3678.349394] e1000 0000:06:07.0: PCI->APIC IRQ transform: INT A -> IRQ 48 [ 3678.409725] e1000 0000:06:07.0: Receive Descriptors set to 4096 [ 3678.409730] e1000 0000:06:07.0: Checksum Offload Disabled [ 3678.409734] e1000 0000:06:07.0: Flow Control Disabled [ 3678.586409] e1000 0000:06:07.0: eth0: (PCI:66MHz:32-bit) 00:11:43:e0:e2:8c [ 3678.586419] e1000 0000:06:07.0: eth0: Intel(R) PRO/1000 Network Connection [ 3678.586642] e1000 0000:07:08.0: PCI->APIC IRQ transform: INT A -> IRQ 49 [ 3678.649854] e1000 0000:07:08.0: Receive Descriptors set to 4096 [ 3678.649859] e1000 0000:07:08.0: Checksum Offload Disabled [ 3678.649863] e1000 0000:07:08.0: Flow Control Disabled [ 3678.826436] e1000 0000:07:08.0: eth1: (PCI:66MHz:32-bit) 00:11:43:e0:e2:8d [ 3678.826444] e1000 0000:07:08.0: eth1: Intel(R) PRO/1000 Network Connection [ 3678.826627] e1000 0000:09:04.0: PCI->APIC IRQ transform: INT A -> IRQ 82 [ 3679.093266] e1000 0000:09:04.0: Receive Descriptors set to 4096 [ 3679.093271] e1000 0000:09:04.0: Checksum Offload Disabled [ 3679.093275] e1000 0000:09:04.0: Flow Control Disabled [ 3679.130239] e1000 0000:09:04.0: eth2: (PCI-X:133MHz:64-bit) 00:04:23:e1:77:6a [ 3679.130246] e1000 0000:09:04.0: eth2: Intel(R) PRO/1000 Network Connection [ 3679.130449] e1000 0000:09:04.1: PCI->APIC IRQ transform: INT B -> IRQ 83 [ 3679.397312] e1000 0000:09:04.1: Receive Descriptors set to 4096 [ 3679.397318] e1000 0000:09:04.1: Checksum Offload Disabled [ 3679.397321] e1000 0000:09:04.1: Flow Control Disabled [ 3679.434350] e1000 0000:09:04.1: eth3: (PCI-X:133MHz:64-bit) 00:04:23:e1:77:6b [ 3679.434360] e1000 0000:09:04.1: eth3: Intel(R) PRO/1000 Network Connection [ 3679.434553] e1000 0000:0a:03.0: PCI->APIC IRQ transform: INT A -> IRQ 77 [ 3679.704072] e1000 0000:0a:03.0: Receive Descriptors set to 4096 [ 3679.704077] e1000 0000:0a:03.0: Checksum Offload Disabled [ 3679.704081] e1000 0000:0a:03.0: Flow Control Disabled [ 3679.738364] e1000 0000:0a:03.0: eth4: (PCI:33MHz:64-bit) 00:04:23:b6:35:6c [ 3679.738371] e1000 0000:0a:03.0: eth4: Intel(R) PRO/1000 Network Connection [ 3679.738538] e1000 0000:0a:03.1: PCI->APIC IRQ transform: INT B -> IRQ 78 [ 3680.046060] e1000 0000:0a:03.1: eth5: (PCI:33MHz:64-bit) 00:04:23:b6:35:6d [ 3680.046067] e1000 0000:0a:03.1: eth5: Intel(R) PRO/1000 Network Connection [ 3682.132415] e1000: eth0 NIC Link is Up 100 Mbps Half Duplex, Flow Control: None [ 3682.224423] e1000: eth1 NIC Link is Up 100 Mbps Half Duplex, Flow Control: None [ 3682.316385] e1000: eth2 NIC Link is Up 100 Mbps Half Duplex, Flow Control: None [ 3682.408391] e1000: eth3 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: None [ 3682.500396] e1000: eth4 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: None [ 3682.708401] e1000: eth5 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX At first I thought it was the NIC drivers but I'm not so sure. I really have no idea where else to look at the moment. Any help is greatly appreciated as I'm struggling with this. If you need more information just ask. Thanks! [1]http://www.cs.fsu.edu/~baker/devices/lxr/http/source/linux/Documentation/networking/e1000.txt?v=2.6.11.8 [2] http://support.dell.com/support/edocs/systems/pe2850/en/ug/t1390aa.htm

    Read the article

  • Solaris 11 Update 1 - Link Aggregation

    - by Wesley Faria
    Solaris 11.1 No início desse mês em um evento mundial da Oracle chamado Oracle Open World foi lançada a nova release do Solaris 11. Ela chega cheia de novidades, são aproximadamente 300 novas funcionalidade em rede, segurança, administração e outros. Hoje vou falar de uma funcionalidade de rede muito interessante que é o Link Aggregation. O Solaris já suporta Link Aggregation desde Solaris 10 Update 1 porem no Solaris 11 Update 1 tivemos incrementos significantes. O Link Aggregation como o próprio nome diz, é a agregação de mais de uma inteface física de rede em uma interface lógica .Veja agumas funcionalidade do Link Aggregation: · Aumentar a largura da banda; · Imcrementar a segurança fazendo Failover e Failback; · Melhora a administração da rede; O Solaris 11.1 suporta 2(dois) tipos de Link Aggregation o Trunk aggregation e o Datalink Multipathing aggregation, ambos trabalham fazendo com que o pacote de rede seja distribuído entre as intefaces da agregação garantindo melhor utilização da rede.vamos ver um pouco melhor cada um deles. Trunk Aggregation O Trunk Aggregation tem como objetivo aumentar a largura de banda, seja para aplicações que possue um tráfego de rede alto seja para consolidação. Por exemplo temos um servidor que foi adquirido para comportar várias máquinas virtuais onde cada uma delas tem uma demanda e esse servidor possue 2(duas) placas de rede. Podemos então criar uma agregação entre essas 2(duas) placas de forma que o Solaris 11.1 vai enchergar as 2(duas) placas como se fosse 1(uma) fazendo com que a largura de banda duplique, veja na figura abaixo: A figura mostra uma agregação com 2(duas) placas físicas NIC 1 e NIC 2 conectadas no mesmo switch e 2(duas) interfaces virtuais VNIC A e VNIC B. Porem para que isso funcione temos que ter um switch com suporte a LACP ( Link Aggregation Control Protocol ). A função do LACP é fazer a aggregação na camada do switch pois se isso não for feito o pacote que sairá do servidor não poderá ser montado quando chegar no switch. Uma outra forma de configuração do Trunk Aggregation é o ponto-a-ponto onde ao invéz de se usar um switch, os 2 servidores são conectados diretamente. Nesse caso a agregação de um servidor irá falar diretamente com a agregação do outro garantindo uma proteção contra falhas e tambem uma largura de banda maior. Vejamos como configurar o Trunk Aggregation: 1 – Verificando quais intefaces disponíveis # dladm show-link 2 – Verificando interfaces # ipadm show-if 3 – Apagando o endereçamento das interfaces existentes # ipadm delete-ip <interface> 4 – Criando o Trunk aggregation # dladm create-aggr -L active -l <interface> -l <interface> aggr0 5 – Listando a agregação criada # dladm show-aggr Data Link Multipath Aggregation Como vimos anteriormente o Trunk aggregation é implementado apenas 1(um) switch que possua suporte a LACP portanto, temos um ponto único de falha que é o switch. Para solucionar esse problema no Solaris 10 utilizavamos o IPMP ( IP Multipathing ) que é a combinação de 2(duas) agregações em um mesmo link ou seja, outro camada de virtualização. Agora com o Solaris 11 Update 1 isso não é mais necessário, voce pode ter uma agregação de 2(duas) interfaces físicas e cada uma conectada a 1(um) swtich diferente, veja a figura abaixo: Temos aqui uma agregação chamada aggr contendo 4(quatro) interfaces físicas sendo que as interfaces NIC 1 e NIC 2 estão conectadas em um Switch e as intefaces NIC 3 e NIC 4 estão conectadas em outro Swicth. Além disso foram criadas mais 4(quatro) interfaces virtuais vnic A, vnic B, vnic C e vnic D que podem ser destinadas a diferentes aplicações/zones. Com isso garantimos alta disponibilidade em todas a camadas pois podemos ter falhas tanto em switches, links como em interfaces de rede físicas. Para configurar siga os mesmo passos da configuração do Trunk Aggregation até o passo 3 depois faça o seguinte: 4 – Criando o Trunk aggregation # dladm create-aggr -m haonly -l <interface> -l <interface> aggr0 5 – Listando a agregação criada # dladm show-aggr Depois de configurado seja no modo Trunk aggregation ou no modo Data Link Multipathing aggregation pode ser feito a troca de um modo para o outro, pode adcionar e remover interfaces físicas ou vituais. Bem pessoal, era isso que eu tinha para mostar sobre a nova funcionalidade do Link Aggregation do Solaris 11 Update 1 espero que tenham gostado, até uma próxima novidade.

    Read the article

  • Cross-domain jQuery using YQL gives robots.txt error

    - by Jens Roland
    On the page http://qxlapps.dk/test.htm I am trying to perform an Ajax load from another domain, qxlapp.dk. I am using James Padolsey's xdomainajax.js plugin from: http://james.padolsey.com/javascript/cross-domain-requests-with-jquery/ When I open my test page, I get no output, but FireBug shows the JSON result, including the error message: "forbidden":"robots.txt for the domain disallows crawling for url: http://qxlapp.dk/projects/dagens_kup/show.php". The robots.txt on the qxlapp.dk domain contains the following: User-agent: Yahoo Pipes 2.0 Allow: / User-agent: * Allow: / So I don't see what the problem is? Shouldn't it pull the page just fine with those settings?

    Read the article

  • URLRewriter.net fails relative paths when using more than one substring in URL

    - by Andreas Strandfelt
    Hi. I have installed the URLRewriter on my server, and it works fine, but I have a rather big problem. Relative links in hyperlinks, CSS-links, images etc. doesn't work when I have URLs with more than one substring. E.g. (sorry, no http:// in front, as I do not have enough reputation): dkbyg.strandweb.dk/Leje-og-udlejning-arbejdskraft leads to the path dkbyg.strandweb.dk/Workers.aspx and works just fine. But dkbyg.strandweb.dk/Leje-og-udlejning-arbejdskraft/Midtjylland leads to dkbyg.strandweb.dk/Workers.aspx?Region=Midtjylland using this line in the Web.config: <rewrite url="~/Leje-og-udlejning-arbejdskraft/(.+)" to="~/Workers.aspx?Region=$1"/> It rewrites just fine, but my relative links doesn't work anymore. CSS, Images, links and so on thinks my root is now http://dkbyg.strandweb.dk/Leje-og-udlejning-arbejdskraft, which of course doesn't exist. Can't this be fixed? All my links are correctly set using the ~/, like this: <asp:HyperLink ID="HyperLink3" CssClass="black_text" NavigateUrl="~/Forgot-Password" runat="server">I have forgotten my password</asp:HyperLink>

    Read the article

  • autopostback problem listbox asp.net

    - by lodun
    I want to add posts(question) like i do that on yahoo answers.When i choose item in "kategorije" control,items can't be loaded in "SUB_kategorije" control. Image My new ascx.cs: 1. protected void Page_Load(object sender, EventArgs e) 2. { 3. 4. 5. if (!Page.IsPostBack) 6. { 7. 8. SqlDataSource ds = new SqlDataSource(); 9. ds.ConnectionString = conn; 10. ds.SelectCommand = "SELECT [ID], [Kategorije] FROM [kategorije] "; 11. kategorije.DataSource = ds; 12. kategorije.DataTextField = "Kategorije"; 13. kategorije.DataValueField = "ID"; 14. kategorije.DataBind(); 15. kategorije.SelectedIndex = 1; 16. 17. SqlDataSource dk = new SqlDataSource(); 18. dk.ConnectionString = conn; 19. dk.SelectCommand = "SELECT * from pod_kategorije WHERE kat_id = " + kategorije.SelectedItem.Value; 20. SUB_kategorije.DataSource = dk; 21. SUB_kategorije.DataTextField = "pkategorija"; 22. SUB_kategorije.DataValueField = "ID"; 23. SUB_kategorije.DataBind(); 24. 25. 26. } 27. 28. 29. 30. 31. } 32. protected void kategorije_SelectedIndexChanged(object sender, EventArgs e) 33. { 34. 35. 36. SqlDataSource dk = new SqlDataSource(); 37. dk.ConnectionString = conn; 38. dk.SelectCommand = "SELECT * from pod_kategorije WHERE [kat_id] = " + kategorije.SelectedItem.Value; 39. SUB_kategorije.DataSource = dk; 40. SUB_kategorije.DataTextField = "pkategorija"; 41. SUB_kategorije.DataValueField = "ID"; 42. SUB_kategorije.DataBind(); 43. 44. 45. } and .ascx: 1. <asp:ListBox ID="kategorije" runat="server" Height="380px" CssClass="kat" AutoPostBack="true" 2. 3. onselectedindexchanged="kategorije_SelectedIndexChanged"></asp:ListBox> 4. 5. <asp:Button ID="Button1" CssClass="posalji" runat="server" Text="click" 6. onclick="Button1_Click" /> 7. 8. 9. 10. <asp:UpdatePanel ID="UpdatePanel10" runat="server"> 11. <ContentTemplate> <asp:ListBox ID="SUB_kategorije" CssClass="pod" Height="150px" runat="server"></asp:ListBox></ContentTemplate> 12. <Triggers> 13. <asp:AsyncPostBackTrigger ControlID="kategorije" EventName="SelectedIndexChanged" /> 14. 15. </Triggers> 16. 17. </asp:UpdatePanel>

    Read the article

  • SWT TabFolder: Weird Drawing Behaviour

    - by JesperGJensen
    Hello StackOverflow Experts Description I have an SWT Page with a TabFolder with a number of dynamically created TabItems. On each TabItem i crate a Composite and set the TabItem.setControl() to the Composite. I then use this Composite as the page on which i draw my items. I draw a set of Controls, including Textbox's and Labels. For the First, Default Tab, this works fine. No problems. Problem On tabs that is not the first tab i have the following problems: I am unable to visually alter then Edited/Enabled state of my Controls. I am unable to visually set the Text content of my elements My Controls look disabled and have a Greyed out look. But i am able to Select the content with my mouse and use CTRL+C to copy it out. So the text contet is there and they are Editable. Visually it is just not updated. Any comments are appeciated, Any requests for code, examples will be supplied and help Welcommed. Updates I tried added the suggest debug loop to the code, where i attempt to enable my Controls. This was the result: [main] INFO [dk.viking.controller.LayerController] - f038.stklok is now Editable [true] and enabled [true] [main] INFO [dk.viking.controller.LayerController] - true Text {} [main] INFO [dk.viking.controller.LayerController] - true Composite {} [main] INFO [dk.viking.controller.LayerController] - true TabFolder {} [main] INFO [dk.viking.controller.LayerController] - true Shell {Viking GUI}

    Read the article

  • Count of memory copies in *nix systems between packet at NIC and user application?

    - by Michael_73
    Hi there, This is just a general question relating to some high-performance computing I've been wondering about. A certain low-latency messaging vendor speaks in its supporting documentation about using raw sockets to transfer the data directly from the network device to the user application and in so doing it speaks about reducing the messaging latency even further than it does anyway (in other admittedly carefully thought-out design decisions). My question is therefore to those that grok the networking stacks on Unix or Unix-like systems. How much difference are they likely to be able to realise using this method? Feel free to answer in terms of memory copies, numbers of whales rescued or areas the size of Wales ;) Their messaging is UDP-based, as I understand it, so there's no problem with establishing TCP connections etc. Any other points of interest on this topic would be gratefully thought about! Best wishes, Mike

    Read the article

  • Tamilnadu HSC (+2) exam results – List of Websites

    - by samsudeen
    Tamilnadu State Board HSC ( +2 ) exam  results is expected to be release around the mid of this month ( probably on May 19). School students can get their marks at the same time from their respective schools. The results are usually published on websites or can availed from  mobile phone service providers through SMS. But it is for sure  most the sites will not be accessed for at least couple hours at the  time of result announcement Below are some of the quality web sites ( includes mirror sites to directly access the results page) that publishes the result links. http://www.tnresults.nic.in/ http://www.squarebrothers.com/ http://results.sify.com/ http://indiaresults.com/ http://www.dge1.tn.nic.in/ http://www.dge2.tn.nic.in/ http://www.dge3.tn.nic.in/ http://www.tngdc.in/ http://www.collegesintamilnadu.com/ http://www.classontheweb.com/ http://www.schools9.com/ http://www.chennaivision.com/ http://www.mygaruda.com/ http://www.tnagar.com/ http://www.indiacollegefinder.com/ http://www.chennaionline.com/ http://www.nakkeeran.com/ http://www.getyourscore.in/ http://www.examresults.net/ http://results.webdunia.com/ http://www.jayanews.in/ http://www.findchennai.com/ Join us on Facebook to read all our stories right inside your Facebook news feed.

    Read the article

  • Bind DHCP Server to Network Bridge

    - by Luke
    My wireless router died, so I decided to route everything through my server. So I installed a second NIC and a wireless card to be my new network: 1 NIC to the Modem, 1 NIC to the switch, and the Wireless to... Well, wireless. Anyways, I got far enough to get DHCP to work on just ONE adapter when I used Internet Connection Sharing (I couldn't get RRAS set up for the life of me), then I decided to try bridging the wireless and second NIC. Now, the DHCP server won't bind to the bridge, but I can enter manual IP's in my clients and it'll connect to the Internet. I also tried changing my wireless adapter's IP to 192.168.0.2, and to 192.168.1.1 to try to set up a separate scope, but to no avail. Running Windows Server 2003

    Read the article

  • No compatible network card

    - by sbintcliffe
    Motherboard: Asus K8N-E Deluxe with onboard NIC (nVidia nForce) Secondary NIC: I've tried using a standard NIC (Device Manager displays this as D-Link DFE-538TX 10/100, but under manufacturer in the General tab of the properties in Windows it states Realtek Semiconductor Corp.) I have downloaded ESXi 4.0.0 build 208167 and cooked to disc. I've booted from it, the .TGZ modules load from the yellow and grey screen, the progress bar reaches to about 60% and like a second later the screen changes and I have the following information on screen; "No compatible network adapter found. Please consult the HCG." I've checked the HCG and found that my motherboard is listed. I also get the same message with the secondary NIC. Any ideas please?

    Read the article

  • Packet drop measured by ethtool, tcpdump and ifconfig

    - by Rayne
    Hi all, I have a question regarding packet drops. I am running a test to determine when packet drops occur. I'm using a Spirent TestCenter through a switch (necessary to aggregate Ethernet traffic from 5 ports to one optical link) to a server using a Myricom card. While running my test, if the input rate is below a certain value, ethtool does not report any drop (except dropped_multicast_filtered which is incrementing at a very slow rate). However, tcpdump reports X number of packets "dropped by kernel". Then if I increase the input rate, ethtool reports drops but "ifconfig eth2" does not. In fact, ifconfig doesn't seem to report any packet drops at all. Do they all measure packet drops at different "levels", i.e. ethtool at the NIC level, tcpdump at the kernel level etc? And am I right to say that in the journey of an incoming packet, the NIC level is the "so-called" first level, then the kernel, then the user application? So any packet drop is likely to happen first at the NIC, then the kernel, then the user application? So if there is no packet drop at the NIC, but packet drop at the kernel, then the bottleneck is not at the NIC? Thank you. Regards, Rayne

    Read the article

  • NAT ports - how do they work?

    - by Davidoper
    I have the following network schema: Computer A: three nics: NIC 1 (eth0): dhcp, public internet NIC 2 (eth1): static 192.168.1.1, gateway for Computer B NIC 3 (eth2): static 192.168.2.1, gateway for Computer C Computer B: static 192.168.1.2, using gateway 192.168.1.1 (NIC 2). Computer C: static 192.168.2.2, using gateway 192.168.2.1 (NIC 3). So I applied this to get NAT working: iptables -t nat -A POSTROUTING -o eth0 -j MASQUERADE Every computer can connect to the internet now. I have been applying rules to the main computer (Computer A), like dropping connections to some ports, e.g ssh: iptables -A INPUT -p tcp --dport 22 -j DROP But for instance, now I would like only allow connections for ports 20,21,22,53 and 80 in Computer C, and ignore the outside traffic if it's not related to those ports. The allowed connections should be FROM Computer C to outside, but not from outside to Computer C (I mean - Computer C is not hosting any HTTP or SSH, but it is going to use them as a client). I guess this sould be done like this: iptables -A OUTPUT -i eth2 -o eth0 -p tcp --dport 21 -m state --state NEW,ESTABLISHED -j ACCEPT iptables -A INPUT -i eth2 -o eth0 -p tcp --sport 21 -m state --state ESTABLISHED -j ACCEPT The last rule (dropping any other traffic different from those) is at the end of the configuration, so -A should be working correctly. The thing is... it is not working. If I put the last rule like this: iptables -A FORWARD -i eth2 -o eth0 -j DROP It just drops everything and, for instance, port 21 (previously opened as you can see above) is not either working. Can you tell me what could I have done wrong? I have been struggling with this problem for some time and I am unable to solve it. Thanks!

    Read the article

  • Server 2008 NAT Internet Not Working

    - by Jack
    I'm trying to set up Routing and Remote Access on Windows Server 2008 R2, I have a network connection that I want to share the internet from to another private network. The server has two NICs which are configured as follows: External NIC (Dynamically assigned by ISP) IP:10.175.4.150 Subnet:255.255.192.0 Gateway:10.175.0.1 DNS:10.175.0.1 Internal NIC IP:172.16.254.1 Subnet:255.255.255.0 Gateway:None DNS:None I have set the external NIC to be the public interface and enabled NAT on it in the RRAS MMC and set the internal NIC to be a private interface. I have also set up the DNS forwarding or whatever it is in the NAT section. From a client (IP:172.16.254.2) I can ping the server and access files on it, when I try to browse the web with the default gateway set to the internal NIC ip I end up getting a 404 page which is returned from the ISPs default gateway. I'm guessing it's something to do with the double NAT possibly. Trying to ping the ISPs default gateway from a private network client just times out as does accessing it directly. I've disabled and reconfigured RRAS multiple times and that doesn't seem to have made a difference, so can anyone tell me what I'm doing wrong? Thanks.

    Read the article

  • Moving Farm to co-location hosting - network settings requirements

    - by Saariko
    I am moving my farm (2 Dell's R620) to a co-location hosting service. I am trying to figure out the secure way to have my network settings The requirements are: VM1 is the working HOST, includes: esxi 5.1, vSphere, 4 clients (w2008r2 all) VM2 has esxi 5.1 installed, and a single machine with Veeam Backup and copy 6.5 - keeping a copy of VM1 clients on the VM2 internal storage (this solution is due to a very small budget - in case of failure on Host 1 - can redirect IP's) Only 2 VM clients require network address and access from the WWAN - ISP provides IP's range for them (with Gateway and DNS) I need connection to the iDrac's from my office (option to create a VPN-SSL tunnel) Connection to the vSphere appliances I want to be able to RDP to the VM clients The current configuration is that each host has the iDrac dedicated nic connected , and another (NIC #1) connected - with a static IP on 192.168.3.x The iDrac's have a static IP from the same network range (19.168.3.x) It will look something like this: My thoughts: On NIC#2 of both hosts I will connected a crossed cable I will give each VM clients that needs internet access a 2ndry VM network with the assigned IP from the ISP open only to web - can not access from the My Question: Should I give IP's (external) to the machines who DO NOT require WWAN Access? - I can't see a way to RDP to them directly if not. Should I use the crossed cable? or just plug NIC #2 to the switch? Will this setup even work? What do I need to verify? What Virtual nic's and/or switches should I create on the Hosts?

    Read the article

  • How do you confirm network adapter is gigabit capable?

    - by StrandedPirate
    Upgrading my network to gigabit speeds and don't know how to determine if the NIC in one of the systems is capable of gigabit speed. The documentation from the manufacturer states this: Network adapter 10/100/1000 Ethernet LAN on system board However when I go to the properties of the NIC under Speed & Duplex my only options are: 10 Mb Full 10 Mb Half 100 Mb Full 100 Mb Half Auto Is there a command line I can run that will give me more detail about the NIC? Windows 7 x64 OS New Info: The new switch I just bought has a light to indicate 1000Mbps. I can tell from the light that this NIC is indeed negotiating at 1000Mbps but I'd still like to know how to determine this from the console in windows.

    Read the article

  • Do all routers really must know all routes to every router?

    - by Philipili
    This is my complicated and long question. First let's talk about the context. Network topology: PC A --- RT A --- RT C --- RT B --- PC B (RT C has a WAN NIC connected to "the cloud") With this situation : PC A must send a packet to PC B Default routes direct packets to the cloud We haven't access to RT C's configuration RT C only knows how to join network A, not network B RT A knows about network B RT B knows about network A RT C's routing table: Destination NIC Gateway 0.0.0.0 WAN Cloud Network A LAN A RT A's WAN RT A's routing table: Destination NIC Gateway 0.0.0.0 WAN LAN A Network B WAN LAN A RT B's routing table: Destination NIC Gateway 0.0.0.0 WAN LAN B Network A WAN LAN B I would like to permit PC A and PC B to communicate, but I don't have access to RT C. Networks B and BC are new. Can PC A send a packet to RT B's WAN NIC (which is possible) and "ask RT B to direct the packet to PC B" ? I believe replacing RT B with a VPN server should do the trick, but I would like to know if it is possible to make it without establishing a new connection.

    Read the article

  • How to remove an "extra" (unwanted) network from a windows 2008 failover cluster?

    - by Trondh
    Hi, We had a severe crash on one node of our 2-node Windows 2008 / Exchange 2007 CCR Cluster the other day, and i tried to rebuild the node from scratch. I'm using this as a rough outline: http://edmckinzie.spaces.live.com/Blog/cns!687C72A5909E4230!508.entry?sa=641979772 The problem: Our cluster was originally setup with only one NIC per host, as this is supposedly supported in Win2008 (no dedicated heartbeat NIC). When I add my freshly installed node to the cluster, it shows up with two cluster networks, "Cluster Network 1" & 2. The existing node's NIC has been placed in one cluster network and my fresh installed has ended up in the other. I can't find anywhere in the GUI to choose which cluster network each physical NIC should be part of, but i KNOW I have done this before. Time is of the essence on this one, so I was hoping someone in here had the answer on the top of their head... Thanks for any pointers. regards, Trond Hindenes

    Read the article

  • Simple Linux program that takes any HTTP/HTTPS request and returns a single page?

    - by ultrasawblade
    I have a Linux box operating as router. There's a NIC that's connected to the internet (WAN), a NIC connected to an 8-port GbE switch (LAN), and a NIC connected to a Linksys wireless N-router (WLAN). Routing between everything is working perfectly. I have security completely disabled on the wireless router, but the WLAN NIC is firewalled such that it will only accept DNS queries and PPTP VPN connections. Currently HTTP/HTTPS traffic and everything else is blocked. I would like to run something that listens on port 80/443 of the WLAN NIC, and, for non VPN'ed connections, given any HTTP/HTTPS request it will return a single webpage saying "Unauthenticated" and explain how to sign into the VPN. A transparent proxy seems to be what I need, but my searches all seem to direct me to Squid, which is already running on my server and seems overkill for this simple task. Is there a simpler, lightweight program out there that does just this or should I just suck it up and run two instances of Squid (or figure out how to configure it)? Or, is this entire VPN thing I'm doing complete nonsense and I should just enable encryption on the wireless router?

    Read the article

  • CentOS 5.8 dig is not resolving ip-address

    - by travisbotello
    I'm running centos 5.8 on a local machine at home. Today I was trying to analyze the DNS-Lookup via dig. $ dig +trace -t A www.heise.de. This is giving me something like this as a response de. 172800 IN NS f.nic.de. de. 172800 IN NS z.nic.de. de. 172800 IN NS s.de.net. de. 172800 IN NS n.de.net. de. 172800 IN NS a.nic.de. de. 172800 IN NS l.de.net. ;; Received 344 bytes from 192.58.128.30#53(192.58.128.30) in 49 ms In contrast my dedicated CentOS machine is returning the following de. 172800 IN NS a.nic.de. de. 172800 IN NS n.de.net. de. 172800 IN NS f.nic.de. de. 172800 IN NS z.nic.de. de. 172800 IN NS l.de.net. de. 172800 IN NS s.de.net. ;; Received 344 bytes from 192.58.128.30#53(j.root-servers.net) in 32 ms As you can see, the last line is different. Any idea why my dedicated machine is giving me the host name of the responding DNS-Server and my local machine is only returning the ip-address? Thanks in advance UPDATE The reverse DNS-Lookup is working without any problems. Also, I just checked this on my local mac and...exactly the same problem occurs. Is it possible that this has to do with the local router/modem/ISP?

    Read the article

  • Hyper-V networking....still not sure which way to go??

    - by CZhale
    We have our Hyper-V server up and running (Windows 2008 ENT SP2) and started to create some of our VMs. The server has 4 total nics. 2 onboard Broadcom 1gb nic cards and a pci dual port Intel Pro cards 1gb. Right now, I have setup 1 broadcom nic to be the hyper-v host nic, and setup the other broadcom nic for the VMs. We are not using the Intel Nics....should we be thinking about teaming?Link Aggregation?? I just want to achieve the best possible setup for the network, but have read many things for and against teaming the nics?? Thoughts?

    Read the article

  • Any program to help me check whether an ethernet channel can support full-length VLAN packet?

    - by Jimm Chen
    Sometimes, I have to face such a situation that I need to quickly and explicitly know whether a full length VLAN packet can traverse between two RJ45 ports. Yes, I mean 802.1Q ethernet frame with Etype=81 00 (diagram below). What I can do now is: Get two Windows PCs, for each PC, intall Intel Gigabit NIC and Intel specific driver to create a virtual NIC, with VLAN ID=3 assigned. Then connect the two PCs to each of the two RJ45 port. Finally execute ping to generate a full-length ethernet packet. ping -f -l 1472 <dest-IP> This way, I can be sure that the sent packet has the maximum "IP data payload" of 1500 bytes(8 bytes of ICMP header and 1472 bytes of ICMP data). If the ping gets reply, I know that the ethernet channel support full-length VLAN packet. From my experiment, some home switch or broad band routers(e.g. Linksys WRT54G) does not support full-length VLAN packet switching, so only ping -f -l 1468 succeeds. You see, I have to use an expensive Intel NIC to carry on that test, quite inconvenient. You know, for most laptop today, they do not equip an Intel NIC, and, even it is an Intel NIC, Intel VLAN driver, Intel has limitations on the models on which VLAN driver can be installed. So, my question is: Is there a small program that can let me send a full-length VLAN packet without installing a dedicated VLAN driver? Or better, the program has a stock feature that does the very job for my situation. Windows programs preferred, Linux solution welcome. Simpler the program, the better. Thank you.

    Read the article

  • Ubuntu 10.04 Windows2003 adding a route for GPO assignment

    - by David Carvalho
    I want the PC's that receive IP from my Ubuntu DHCP3-server to be able to retrieve the GPOs that are on my windows 2003 server. I'm using virtualbox and 3 virtual machines: 1 windows 2003 server 192.168.0.2 with 1 NIC (internal network). 1 ubuntu server 10.04 lts 192.168.0.1 with 1 NIC (internal network) and 3 aliases 192.168.21.0, 192.168.22.0, 192.168.100.0 1 Windows XP machine with 3 NIC's (internal network).

    Read the article

  • Very Slow DSL (ethernet) speed [New Interesting Update]

    - by Abhijit
    Very IMPORTANT and INTERESTING UPDATE: Due to some reason I just thought to do a complete new setup and this time I decided to again have openSUSE plus ubuntu. So I first reinstall lubuntu and then I installed OpenSUSE 12.2 (64 bit). Now, my DSL speed is working very normal and fine on opensuse. So this is very scary. Is it possible for any operating system to manipulate my NIC so that it will work fine only on that operating system and not on another os? Regarding positive thinking and not being paranoid, what is it that makes ONLY suse to get my NIC to work at normal speed but ubuntu can not do it? Not even fedora? Not even linux mint? What all these OS are lacking that enables suse to work great? == ORIGINAL QUESTION == I 'was' on opensuse 12.2 when my dsl speed was normal. Yesterday I switched from opensuse to ubuntu 12.04 and speed decreased. It came to range of 7-10-13-20-25-kbps. Then I switch to linux mint, and then to fedora. Still slow speed. When I was in ubuntu I disabled ipv6 but still no luck. Now I am in fedora but this time with DIFFERENT ISP. And still I am getting very slow sped. So my guess is this is nothing to do with os. What can be wrong? Is this problem of NIC? Does NIC speed decreases over time? Does NIC life ends over time as with keyboard or mouse? Help please All the os I used are 64 bit and my laptop is Compaq Presario A965Tu Intel Centrino DUal Core. Interesting thing to notice is I get normal speed while downloading torrent inside torrent client softwares. This slow speed issue applied to download from any web browser or installing software using terminal.

    Read the article

< Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >