Search Results

Search found 21455 results on 859 pages for 'setup exe'.

Page 10/859 | < Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >

  • Deserializing classes from XML generated using XSD.exe

    - by heap
    I have classes generated (using xsd.exe) from an .xsd that I can serialize just fine, but when I try and deserialize it, I get the error: {"<XMLLanguages xmlns='http://tempuri.org/XMLLanguages.xsd'> was not expected."} I've searched for a couple of hours and found most peoples problems lie in not declaring namespaces in their xsd/xml, not defining namespaces in their classes, etc, but I can't find a solution for my problem. Here are code snippets for the relevant classes. <?xml version="1.0" encoding="utf-8"?> <xs:schema id="SetupData" targetNamespace="http://tempuri.org/XMLLanguages.xsd" elementFormDefault="qualified" xmlns="http://tempuri.org/XMLLanguages.xsd" xmlns:xs="http://www.w3.org/2001/XMLSchema" > <xs:element name="XMLLanguages"> <xs:complexType> <xs:sequence> <xs:element name="Tier" minOccurs="1" maxOccurs="unbounded"> <xs:complexType> <xs:sequence> <xs:element name="L" minOccurs="1" maxOccurs="unbounded" type="Language"/> </xs:sequence> <xs:attribute name="TierID" type="xs:int"/> </xs:complexType> </xs:element> </xs:sequence> </xs:complexType> </xs:element> <xs:complexType name="Language"> <xs:sequence> <xs:element name="LangID" type="xs:int"/> <xs:element name="Tier" type="xs:int"/> <xs:element name ="Name" type="xs:string"/> </xs:sequence> <xs:attribute name ="PassRate" type="xs:int"/> </xs:complexType> </xs:schema> And the class: /// <remarks/> [System.CodeDom.Compiler.GeneratedCodeAttribute("xsd", "4.0.30319.1")] [System.SerializableAttribute()] [System.Diagnostics.DebuggerStepThroughAttribute()] [System.ComponentModel.DesignerCategoryAttribute("code")] [System.Xml.Serialization.XmlTypeAttribute(Namespace = "http://tempuri.org/XMLLanguages.xsd")] [System.Xml.Serialization.XmlRootAttribute(Namespace = "http://tempuri.org/XMLLanguages.xsd", IsNullable = false)] public partial class XMLLanguages { private List<XMLLanguagesTier> tierField; /// <remarks/> [System.Xml.Serialization.XmlElementAttribute("Tier")] public List<XMLLanguagesTier> Tiers { get { return this.tierField; } set { this.tierField = value; } } } And a the line in XML causing the error: <XMLLanguages xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://tempuri.org/XMLLanguages.xsd">

    Read the article

  • Touch gestures in IE not working without explorer.exe being run once

    - by Michael
    Edit: Rephrasing my question: Upon further troubleshooting, I can conclude that: Touch gestures (dragging, pinch to zoom, touch-and-hold right click) in Internet Explorer start to work when: The system has been running for ~2 minutes. This coincides with the delayed start of services. Explorer.exe is being run, then killed. I assume Explorer.exe starts some services? The services with delayed start are as follows: Security Center Software Protection Windows Defender, Search and Update Windows Font Cache Service Microsoft .NET Framework NGEN v4.0.30319_X64 and X86 I see no connection between these services and touch gestures, but just in case, I manually tried starting these services, but without luck. What else happens delayed after system boot, which also happens when explorer is started? Old question: Details: Internet Explorer 9 and Windows 7 Professional, running on a HP TouchSmart (touch screen PC). It is going to be a kiosk PC (running a custom GUI for displaying websites). Scenario 1: When running Internet Explorer as a normal program in Windows 7, touch functions work perfectly. I can scroll the website by dragging it with my finger, I can pinch zoom and I can touch-and-hold right click. I now change the default shell in Windows to Internet Explorer (ie. IE starts instead of explorer.exe). Internet Explorer of course starts up when logging in. However, touch functions are reduced to basic clicking (no dragging, no pinch zooming, no touch-and-hold right click). Then I manually start explorer.exe, and the touch functions work again! And here is the weird part: When I kill explorer.exe, the touch functions keeps working - even if I close IE and start a new instance. Scenario 2: The exact same, but instead of changing the default shell to Internet Explorer, I change it to my own program, which uses an embedded Internet Explorer ("WebBrowser"). Same thing happens. What I've tried: Autorun programs: When explorer.exe launches, it launches all the autorun programs. There are no relevant programs being run by explorer, but just in case, I have manually started all the autorun programs, so that it is identical (but without explorer.exe) to a normal login. It still does not work (until I launch explorer.exe). Specifically TabTip.exe, TabTip32.exe and wisptis.exe are all running. All services are also started. To sum it up Running explorer.exe once changes something in the touch capabilities of Internet Explorer. It doesn't matter if explorer.exe is running - as long as it has been run once. Does anyone know what causes this behavior? Or how I can circumvent it neatly?

    Read the article

  • [inno setup] Pascal and Delphi Syntax Error?!

    - by neo-nant
    This is the code section from inno setup.My intention is to make two Checkbox where at a time one is being selected. But this code return error. [code] section: procedure CheckBoxOnClick(Sender: TObject); var Box2,CheckBox: TNewCheckBox; begin if CheckBox.Checked then CheckBox.State := cbUnchecked; Box2.State := cbChecked; else //THIS LINE RETURNS AN ERROR: "Identifier Expected." CheckBox.State := cbChecked; Box2.State := cbUnchecked; end; procedure Box2OnClick(Sender: TObject); var Box2,CheckBox: TNewCheckBox; begin if Box2.Checked then CheckBox.State := cbChecked; Box2.State := cbUnchecked; else //same error CheckBox.State := cbUnchecked; Box2.State := cbChecked; end; procedure CreateTheWizardPages; var Page: TWizardPage; Box2,CheckBox: TNewCheckBox; begin { TButton and others } Page := CreateCustomPage(wpWelcome, '', ''); CheckBox := TNewCheckBox.Create(Page); CheckBox.Top :=ScaleY(8)+ScaleX(50); CheckBox.Width := Page.SurfaceWidth; CheckBox.Height := ScaleY(17); CheckBox.Caption := 'Do this'; CheckBox.Checked := True; CheckBox.OnClick := @CheckBoxOnClick; CheckBox.Parent := Page.Surface; Box2 := TNewCheckBox.Create(Page); Box2.Top :=ScaleY(8)+ScaleX(70); Box2.Width := Page.SurfaceWidth; Box2.Height := ScaleY(17); Box2.Caption := 'No,Thanks.'; Box2.Checked := False; Box2.OnClick := @Box2OnClick; Box2.Parent := Page.Surface; end; procedure InitializeWizard(); //var begin { Custom wizard pages } CreateTheWizardPages; end; Please tell me where to change..

    Read the article

  • WiX 3 Tutorial: Generating file/directory fragments with Heat.exe

    - by Mladen Prajdic
    In previous posts I’ve shown you our SuperForm test application solution structure and how the main wxs and wxi include file look like. In this post I’ll show you how to automate inclusion of files to install into your build process. For our SuperForm application we have a single exe to install. But in the real world we have 10s or 100s of different files from dll’s to resource files like pictures. It all depends on what kind of application you’re building. Writing a directory structure for so many files by hand is out of the question. What we need is an automated way to create this structure. Enter Heat.exe. Heat is a command line utility to harvest a file, directory, Visual Studio project, IIS website or performance counters. You might ask what harvesting means? Harvesting is converting a source (file, directory, …) into a component structure saved in a WiX fragment (a wxs) file. There are 2 options you can use: Create a static wxs fragment with Heat and include it in your project. The pro of this is that you can add or remove components by hand. The con is that you have to do the pro part by hand. Automation always beats manual labor. Run heat command line utility in a pre-build event of your WiX project. I prefer this way. By always recreating the whole fragment you don’t have to worry about missing any new files you add. The con of this is that you’ll include files that you otherwise might not want to. There is no perfect solution so pick one and deal with it. I prefer using the second way. A neat way of overcoming the con of the second option is to have a post-build event on your main application project (SuperForm.MainApp in our case) to copy the files needed to be installed in a special location and have the Heat.exe read them from there. I haven’t set this up for this tutorial and I’m simply including all files from the default SuperForm.MainApp \bin directory. Remember how we created a System Environment variable called SuperFormFilesDir? This is where we’ll use it for the first time. The command line text that you have to put into the pre-build event of your WiX project looks like this: "$(WIX)bin\heat.exe" dir "$(SuperFormFilesDir)" -cg SuperFormFiles -gg -scom -sreg -sfrag -srd -dr INSTALLLOCATION -var env.SuperFormFilesDir -out "$(ProjectDir)Fragments\FilesFragment.wxs" After you install WiX you’ll get the WIX environment variable. In the pre/post-build events environment variables are referenced like this: $(WIX). By using this you don’t have to think about the installation path of the WiX. Remember: for 32 bit applications Program files folder is named differently between 32 and 64 bit systems. $(ProjectDir) is obviously the path to your project and is a Visual Studio built in variable. You can view all Heat.exe options by running it without parameters but I’ll explain some that stick out the most. dir "$(SuperFormFilesDir)": tell Heat to harvest the whole directory at the set location. That is the location we’ve set in our System Environment variable. –cg SuperFormFiles: the name of the Component group that will be created. This name is included in out Feature tag as is seen in the previous post. -dr INSTALLLOCATION: the directory reference this fragment will fall under. You can see the top level directory structure in the previous post. -var env.SuperFormFilesDir: the name of the variable that will replace the SourceDir text that would otherwise appear in the fragment file. -out "$(ProjectDir)Fragments\FilesFragment.wxs": the full path and name under which the fragment file will be saved. If you have source control you have to include the FilesFragment.wxs into your project but remove its source control binding. The auto generated FilesFragment.wxs for our test app looks like this: <?xml version="1.0" encoding="utf-8"?><Wix xmlns="http://schemas.microsoft.com/wix/2006/wi"> <Fragment> <ComponentGroup Id="SuperFormFiles"> <ComponentRef Id="cmp5BB40DB822CAA7C5295227894A07502E" /> <ComponentRef Id="cmpCFD331F5E0E471FC42A1334A1098E144" /> <ComponentRef Id="cmp4614DD03D8974B7C1FC39E7B82F19574" /> <ComponentRef Id="cmpDF166522884E2454382277128BD866EC" /> </ComponentGroup> </Fragment> <Fragment> <DirectoryRef Id="INSTALLLOCATION"> <Component Id="cmp5BB40DB822CAA7C5295227894A07502E" Guid="{117E3352-2F0C-4E19-AD96-03D354751B8D}"> <File Id="filDCA561ABF8964292B6BC0D0726E8EFAD" KeyPath="yes" Source="$(env.SuperFormFilesDir)\SuperForm.MainApp.exe" /> </Component> <Component Id="cmpCFD331F5E0E471FC42A1334A1098E144" Guid="{369A2347-97DD-45CA-A4D1-62BB706EA329}"> <File Id="filA9BE65B2AB60F3CE41105364EDE33D27" KeyPath="yes" Source="$(env.SuperFormFilesDir)\SuperForm.MainApp.pdb" /> </Component> <Component Id="cmp4614DD03D8974B7C1FC39E7B82F19574" Guid="{3443EBE2-168F-4380-BC41-26D71A0DB1C7}"> <File Id="fil5102E75B91F3DAFA6F70DA57F4C126ED" KeyPath="yes" Source="$(env.SuperFormFilesDir)\SuperForm.MainApp.vshost.exe" /> </Component> <Component Id="cmpDF166522884E2454382277128BD866EC" Guid="{0C0F3D18-56EB-41FE-B0BD-FD2C131572DB}"> <File Id="filF7CA5083B4997E1DEC435554423E675C" KeyPath="yes" Source="$(env.SuperFormFilesDir)\SuperForm.MainApp.vshost.exe.manifest" /> </Component> </DirectoryRef> </Fragment></Wix> The $(env.SuperFormFilesDir) will be replaced at build time with the directory where the files to be installed are located. There is nothing too complicated about this. In the end it turns out that this sort of automation is great! There are a few other ways that Heat.exe can compose the wxs file but this is the one I prefer. It just seems the clearest. Play with its options to see what can it do. It’s one awesome little tool.   WiX 3 tutorial by Mladen Prajdic navigation WiX 3 Tutorial: Solution/Project structure and Dev resources WiX 3 Tutorial: Understanding main wxs and wxi file WiX 3 Tutorial: Generating file/directory fragments with Heat.exe

    Read the article

  • I need help in inno setup custom page

    - by vinutavishal
    in inno setup i hav created a custom page with following code and has 3 text boxes now i want to validate that text box on custom form next button click if in text.text='2121212' something text is entered by user then only next button enabled pls help any one its urgent [CustomMessages] CustomForm_Caption=CustomForm Caption CustomForm_Description=CustomForm Description CustomForm_Label1_Caption0=College Name: CustomForm_Label2_Caption0=Product Type: CustomForm_Label3_Caption0=Product ID: [Code] var Label1: TLabel; Label2: TLabel; Label3: TLabel; Edit1: TEdit; Edit2: TEdit; Edit3: TEdit; Edit4: TEdit; Edit5: TEdit; Edit6: TEdit; { CustomForm_Activate } procedure CustomForm_Activate(Page: TWizardPage); begin // enter code here... end; { CustomForm_ShouldSkipPage } function CustomForm_ShouldSkipPage(Page: TWizardPage): Boolean; begin Result := False; end; { CustomForm_BackButtonClick } function CustomForm_BackButtonClick(Page: TWizardPage): Boolean; begin Result := True; end; { CustomForm_NextkButtonClick } function CustomForm_NextButtonClick(Page: TWizardPage): Boolean; begin RegWriteStringValue(HKEY_LOCAL_MACHINE, 'Software\SGS2.2\CS', 'College Name', Edit1.Text); RegWriteStringValue(HKEY_LOCAL_MACHINE, 'Software\SGS2.2\CS', 'Product Type', Edit2.Text); RegWriteStringValue(HKEY_LOCAL_MACHINE, 'Software\SGS2.2\CS', 'Product ID', Edit3.Text); Result := True; end; { CustomForm_CancelButtonClick } procedure CustomForm_CancelButtonClick(Page: TWizardPage; var Cancel, Confirm: Boolean); begin // enter code here... end; { CustomForm_CreatePage } function CustomForm_CreatePage(PreviousPageId: Integer): Integer; var Page: TWizardPage; begin Page := CreateCustomPage( PreviousPageId, ExpandConstant('{cm:CustomForm_Caption}'), ExpandConstant('{cm:CustomForm_Description}') ); { Label1 } Label1 := TLabel.Create(Page); with Label1 do begin Parent := Page.Surface; Caption := ExpandConstant('{cm:CustomForm_Label1_Caption0}'); Left := ScaleX(16); Top := ScaleY(24); Width := ScaleX(70); Height := ScaleY(13); end; { Label2 } Label2 := TLabel.Create(Page); with Label2 do begin Parent := Page.Surface; Caption := ExpandConstant('{cm:CustomForm_Label2_Caption0}'); Left := ScaleX(17); Top := ScaleY(56); Width := ScaleX(70); Height := ScaleY(13); end; { Label3 } Label3 := TLabel.Create(Page); with Label3 do begin Parent := Page.Surface; Caption := ExpandConstant('{cm:CustomForm_Label3_Caption0}'); Left := ScaleX(17); Top := ScaleY(88); Width := ScaleX(70); Height := ScaleY(13); end; { Edit1 } Edit1 := TEdit.Create(Page); with Edit1 do begin Parent := Page.Surface; Left := ScaleX(115); Top := ScaleY(24); Width := ScaleX(273); Height := ScaleY(21); TabOrder := 0; end; { Edit2 } Edit2 := TEdit.Create(Page); with Edit2 do begin Parent := Page.Surface; Left := ScaleX(115); Top := ScaleY(56); Width := ScaleX(273); Height := ScaleY(21); TabOrder := 1; end; { Edit3 } Edit3 := TEdit.Create(Page); with Edit3 do begin Parent := Page.Surface; Left := ScaleX(115); Top := ScaleY(88); Width := ScaleX(273); Height := ScaleY(21); TabOrder := 2; end; with Page do begin OnActivate := @CustomForm_Activate; OnShouldSkipPage := @CustomForm_ShouldSkipPage; OnBackButtonClick := @CustomForm_BackButtonClick; OnNextButtonClick := @CustomForm_NextButtonClick; OnCancelButtonClick := @CustomForm_CancelButtonClick; end; Result := Page.ID; end; { CustomForm_InitializeWizard } procedure InitializeWizard(); begin CustomForm_CreatePage(wpWelcome); end;

    Read the article

  • Why is 50.22.53.71 hitting my localhost node.js in an attempt to find a php setup

    - by laggingreflex
    I just created a new app using angular-fullstack yeoman generator, edited it a bit to my liking, and ran it with grunt on my localhost, and immediately upon starting up I get this flood of requests to paths that I haven't even defined. Is this a hacking attempt? And if so, how does the hacker (human or bot) immediately know where my server is and when it came online? Note that I haven't made anything online, it's just a localhost setup and I'm merely connected to the internet. (Although my router does allow 80 port incoming.) Whois shows that the IP address belongs to a SoftLayer Technologies. Never heard of it. Express server listening on 80, in development mode GET / [200] | 127.0.0.1 (Chrome 31.0.1650) GET /w00tw00t.at.blackhats.romanian.anti-sec:) [404] | 50.22.53.71 (Other) GET /scripts/setup.php [404] | 50.22.53.71 (Other) GET /admin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /admin/pma/scripts/setup.php [404] | 50.22.53.71 (Other) GET /admin/phpmyadmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /db/scripts/setup.php [404] | 50.22.53.71 (Other) GET /dbadmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /myadmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /mysql/scripts/setup.php [404] | 50.22.53.71 (Other) GET /mysqladmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /typo3/phpmyadmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /phpadmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /phpMyAdmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /phpmyadmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /phpmyadmin1/scripts/setup.php [404] | 50.22.53.71 (Other) GET /phpmyadmin2/scripts/setup.php [404] | 50.22.53.71 (Other) GET /pma/scripts/setup.php [404] | 50.22.53.71 (Other) GET /web/phpMyAdmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /xampp/phpmyadmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /web/scripts/setup.php [404] | 50.22.53.71 (Other) GET /php-my-admin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /websql/scripts/setup.php [404] | 50.22.53.71 (Other) GET /phpmyadmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /phpMyAdmin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /phpMyAdmin-2/scripts/setup.php [404] | 50.22.53.71 (Other) GET /php-my-admin/scripts/setup.php [404] | 50.22.53.71 (Other) GET /phpMyAdmin-2.5.5/index.php [404] | 50.22.53.71 (Other) GET /phpMyAdmin-2.5.5-pl1/index.php [404] | 50.22.53.71 (Other) GET /phpMyAdmin/ [404] | 50.22.53.71 (Other) GET /phpmyadmin/ [404] | 50.22.53.71 (Other) GET /mysqladmin/ [404] | 50.22.53.71 (Other)

    Read the article

  • How to force InnoSetup to create an uninstall log file

    - by mkva
    Hi I'm using InnoSetup for creating my application installers and I set the "SetupLogging=yes" flag to always create a setup-log file in the %TEMP% directory. This works fine for the installation procedure. Unfortunately, InnoSetup will not create such a log file when I uninstall the application. Is there a flag / possibility to force InnoSetup to also create an uninstall log file?

    Read the article

  • Launch Condition to Detect Office 2010 Applications

    - by Amitd
    Hi , I was trying to create a setup project using VS2008. Is there anyway to detect if a particular Office 2010 application is installed or not? (as a prerequisite) .eg: i want to detect if Powerpoint 2010 is installed on client machine. I was trying to use windows installer search option in lauch condition but unable to find what is component id of powerpoint 2010? Are there any more ways to detect the same? (can be programmatic)

    Read the article

  • Deployment of SQL compact Edition (SDF files) using Setup project

    - by Emad
    Hi, I have a C#.NET desktop application using SQL Compact edition as data store. The application should be used by any user on the machine and all should be seeing the same data ( data should not different per user). I am wondering where should I deploy the SDF file? User's Personal data folder (My Documents) means each user will have a separate database. Deploying on the same folder as the application causes vista to copy the file to \USers\Appdata\local\VirtualStore\ and it seems to make different copies for each user. Where is it best to deploy the SDF file to ensure all users are looking at the same data?

    Read the article

  • VPS nameserver setup?

    - by mathon12
    Hi, I bought a VPS a few days back and had a domain name registered. It gave me 2 nameservers. I only have shell access (no Cpanel/WHM) and it's running CentOS 5. I can visit my site with http://IP/ but not with http://domain.com. What changes do I need to make so that I can visit my site with http://domain.com. I'm really new at this and any help would be greatly appreciated. Thanks.

    Read the article

  • Space in Directory Parameter of svcutil.exe

    - by Drew Frisk
    I'm attempting to download metadata for a WCF service using svcutil but I'm running into issues with the /directory:< parameter. The directory I want to save to has a space in it: C:\Service References\Logging so when I execute /t:metadata I receive the following error: Error: The directory 'C:\Program Files (x86)\Microsoft SDKs\Windows\v8.0A\bin\NETFX 4.0 Tools\References\Logging' could not be found. Verify that the directory exists and that you have the appropriate permissions to read it. It looks to me like the space in "Service References" is causing the issue. From my understanding of command shell (which is very little) spaces act as delimiters for an executable. So I tried escaping the space with a carrot Service^ References and surrounding the path in double quotes "C:\Service References\Logging" but neither of those seem to be working, as the /directory: parameter doesn't recognize them as valid characters in the value. I haven't been able to find any direction in regards to this and svcutil, so I'm at a loss right now. I could download the files to a temp folder and then move them, but I would prefer not to take that approach. I would appreciate any direction that could be given on trying to resolve this. Thanks in advance.

    Read the article

  • Will running aspnet_regiis.exe -ir create any problems?

    - by alexander-strandberg
    Hi there. I've asked a question about changing the version of .Net sites in the IIS. If it affects classic asp sites etc (See Does asp.net setting affect classic asp (IIS 6 settings)) And that seems fine. So my follow-up question is, will running this command get me fired? What it does is changing the default value (and all existing?) of the .net version to 2.0. This wont affect any of the .net sites since they're allready versioned to 2.0. The classic asp pages needs to get its app pools updated so its functionoal with 2.0 but may I run into any other troubles? I've tried doing this on a test environment and no sites whet down during the installation period (from the command) but I did not have any classic asp sites or any .net sites running though (which I should test, come to think about it) but may something else break? Is this command doing anything else? We have some very large sites running and we cannot have downtime periods so I need to be 100% sure that this command is safe. Since all sites go down everytime we change a new sites .net version number we need to get this fix live asap. Any good ideas?

    Read the article

  • Modify cmd.exe properties using the command prompt

    - by CodexArcanum
    Isn't that nicely recursive? I've got a portable command prompt on my external drive, and it has a nice .bat file to configure some initial settings, but I'd like more! Here's what I know how to set from .bat: Colors = (color XY) where x and y are hex digits for the predefined colors Prompt = (prompt $p$g) sets the prompt to "C:\etc\etc " the default prompt Title = (title "text") sets the window title to "text" Screen Size = (mode con: cols=XX lines=YY) sets the columns and lines size of the window Path = (SET PATH=%~d0\bin;%PATH%) sets up local path to my tools and appends the computer's path So that's all great. But there are a few settings I can't seem to set from the bat. Like, how would I set these up wihtout using the Properties dialogue: Buffer = not screen size, but the buffer Options like quick edit mode and autocomplete Popup colors Font. And can you use a font on the portable drive, or must it be installed to work? Command history options

    Read the article

  • Including .Net Framework 3.5 SP1 in prerequisites for VS 2005 Setup Project

    - by joshrobb
    I have a problem. The thing is that I am using Visual Studio 2005 and .Net Framework 3.5 sp1. I have created the app and I want to have the .Net Framework prerequisite installed before however I can only select 2.0 . This wont go well since some columns in some of my grids will be arranged differently along with other problems. Is there any add-ins or something I can use to included .Net Framework 3.5 sp1 in my prerequisite list?

    Read the article

  • Change size of a custom page in Inno Setup

    - by Paja
    The following image shows the size of a standard custom page: I've intentionally removed the panel on top, where you usually see Caption, Description and Logo. So you can see that the actual size of the page is quite small - there are gaps on top, left and right sides. Is there any way to resize the page, so there are no gaps? I want the image to take the whole space. I create the page using CreateCustomPage function.

    Read the article

  • XSD.exe question about include files and code generation

    - by Roger Willcocks
    If you have an XSD with an includes reference. Is it possible to generate 2 separate class files. 1 for the XSD, and 1 for the included XSD? My Scenario 4 XSDs, each of which share 15-20 element definitions in common. Rather than maintaining, I'd like to end up with the 4 XSDs all referencing a fifth file with the common definitions, and code generating 5 .cs files to use.

    Read the article

  • Open + Save .exe file in notepad makes it corrupted

    - by Jacob Kofoed
    Hi, I just published this simple console application that is supposed to show a textbox with the value of a setting called "userID" with value 1001. This works like a charm. Now what I need is to change this value outside the editor, from notepad etc. When I open the application a lot in there is non-sence (& o! -å Þþþ,o" Ü+) etc. but with a quick (ctrl + F) I found the value 1001, and changed this to some other integer. I ran the application again, and it failed, didn't even give any userful error-message. At a point I tried just opening a newly published non-corrupted version of the application, didn't change anything, then saved from notepad, and it were also corrupted. It seems like notepad can't open some characters or something. Do I need to publish the application in some specific text-unicode language or something? Help much appreciated :) I know it sounds like a stupid application, but it is just a test of concept :) I use vb.net for this

    Read the article

  • setup Qt and PyQt on mac osx so my app can also deployable on windows

    - by hk_programmer
    Hi, I've been coding with Python and C++ and now need to work on building a gui for data visualization purposes. I work on Mac Snow Leopard (intel), python 3.1 using gcc 4.2.1 (from Xcode 3.1) I wanted to first install Qt and then PyQt. And my goals are to be able to: - quickly prototype GUI and the accompanied logic that drives the GUI using PyQt and python - if I decided I need the speed, or if it's fairly easy to translate my GUI into C++ using the Qt tools, I have the options to translate my app into C++ - Be able to deploy my application onto Windows (both the python and c++ version of my app) Give the goals above, what are the correct steps I should take and what issues i should be aware of when setting up Qt and PyQt. Which other deployment tools do I need? From my readings so far, here's what I have: download the Qt source for mac and configure it with -platform macx-g++42 -arch x86_64 -no-framework (i've read somewhere that building as framework causes some trouble in deployment and/or debugging, can't find the article anymore) download latest SIP source and build download latest PyQt and build from source (any special options I should pay attention to?) For deployment, I've read that I would need to use py2exe/cx_freeze for windows, p2app for mac: http://arstechnica.com/open-source/guides/2009/03/how-to-deploying-pyqt-applications-on-windows-and-mac-os-x.ars but seems like what the article describe is deploying an app you build on windows on the windows platform and vice versa. How do you deploy to windows (is it even possible?) if you are writing your Qt app on a mac ? Really appreciate the help

    Read the article

  • Registry based components with Inno Setup

    - by cyxou
    Hello guys! I'm creating an application for my company. And the goal is to create a universal installer that will be checking user's registry for specific apps installed and according to these apps would create a list of available installation components in "Select Components" window. And that's the particular problem I'm stacked with. I've already created the installer, but a user have to check/uncheck components he doesn't need because he doesn't use specific app. That is definitely not a good way of doing thing I guess... So I'm asking for help, please. Could this be implemented through "Select Components" window and how or I should create custom wizard page with checkboxes (again - How)? Many thx in advance.

    Read the article

  • How to find which w3wp.exe to attach when debugging your SharePiont2010 project

    - by ybbest
    When debugging SharePoint2010 project, you need to attach w3wp.exe process, however there are often quite a few of them and it is very hard to figure out which one to attach. Today, I will show you how to find out which process to attach using a tool called process explorer. 1. Download the process explorer and run it after you download it. 2. Find the w3wp.exe processes under wininit.exe right-click the columns header and click Select Columns. 3. Include Command Line under Process Image. 4. Now you can see your IIS site name next to w3wp.exe, in my case I’d like to attach the “SharePoint – BenDev80″.You can see the PID of the process is 2920. 5. From the above process you know the process ID you’d like to attach is 2920, you can then go ahead to attach the process from Visual Studio.

    Read the article

  • Redirecting to a diferent exe for download based on user agent

    - by Ra
    I own a Linux-Apache site where I host exe files for download. Now, when a user clicks this link to my site (published on another site): http://mysite.com/downloads/file.exe I need to dynamically check their user agent and redirect them to either http://mysite.com/downloads/file-1.exe or http://mysite.com/downloads/file-2.exe It seems to me that I have to options: Put a .htaccess file stating that .exe files should be considered to be scripts. Then write a script that checks the user agent and redirects to a real exe placed in another folder. Call this script file.exe. Use Apache mod-rewrite to point file.exe to redirect.php. Which of these is better? Any other considerations? Thanks.

    Read the article

  • The great Vanishing Act of INetMgr.exe on my Windows 7 x64 system

    - by marc_s
    I'm facing an odd issue with the IIS Manager on Windows 7 (x64). At home, I have Win7 Professional, and when I check my IIS manager icon in the start menu, I see it links to %windir%\system32\inetsrv\InetMgr.exe When I launch this from the command line, it works like a charm. At work, however, I have Windows 7 Enterprise (x64), and when I check my link in the start menu, the entry is exactly the same. If I click on it - it works like a charm. Now if I'd like to launch it from the command line (cmd.exe or TakeCommand), however - the file just isn't there - a DIR %windir%\system32\inetsrv\*.exe shows a number of files, including a "inetmgr6.exe" - but no "inetmgr.exe" - and of course, I can't launch it either :-( Strangely enough, when I look at the directory %windir%\system32\INetSrv in Windows Explorer or Windows Powershell, I SEE the INetMgr.exe file and I can launch it - no problem. What the **** is going on here? How can I find the INetMgr.exe from my classic command line and launch it from there?? UPDATE: ok, some updates. On my work laptop, the INetMgr.exe file appears to really be located in a directory called c:\windows\syswow64\inetsrv (I'm recalling from memory, so don't quote me on the directory name - something like that). I can see this if I search for it in e.g. Powershell or Windows 7 Explorer. However, from a "classic" command line like cmd.exe, it appears to be in c:\windows\system32\inetsrv ..... hmmm.... trouble is - even though I now know where the file really is, I cannot access that directory from my classic command line - not even if I'm running cmd.exe as admin with elevated privileges....... so I know where the file is, but that still doesn't solve my problem :-(

    Read the article

< Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >