  • Redundant APC UPS units, single server set up

    - by Sholom
    Hi All We have a very simple set up, looking for a very simple (reliable) solution: Setup: One Dell box with redundant power supplies running Windows 2003, plugged into two separate APC SmartUPS 1500 units (USB, no smart cards) on two separate circuits. Solution required: IF (UPS1 = Low) AND (UPS2 = Low) THEN: Shutdown gracefully ELSE: DO NOTHING!! APCUPSD only allowes for one instance (and therefore one UPS) in a windows environment. PowerChute can't do this without using APC Smart Cards which means utilizing our switch, but the switch does not have redundant power supplies, so it will only live for as long as one of the two UPS units. And no, i don't have the budget to buy two smart cards pluse a switch with redundancy ;) Thanks

    Read the article

  • Setting the date format in Atlassian Crucible

    - by pwan
    When I set up a review in Atlassian Crucible, and I set a date, it displays it in DD/MM/YYYY I'd like to switch that over to MM/DD/YYYY, but I don't see anywhere in the configuration to switch that. The closest setting I see is for the timezone, which I have set to EST. I have Crucible running on a CentOS 6.2 machine that's set to UTC I'm using Crucible version 2.7.14 Build:20120612060728 2012-06-12 My locale is currently set to en_US.UTF-8 > locale | grep LC_TIME LC_TIME="en_US.UTF-8" Can someone point out how I can switch the date format in Crucible ?

    Read the article

  • Choosing a home network layout

    - by James M.
    I have a server, 4 PC's, a network printer, a switch and an ADSL modem. Currently the server runs Red Hat 9 and sits between the internet and the other PCs like in http://upload.wikimedia.org/wikipedia/en/1/12/Sample-network-diagram.png I have bought a new server PC to replace the old one, and I plan to install Fedora Core linux on it. The server acts as web and file server. The PCs all run Windows. Alternatively, I could connect the new server and all PCs to the switch, and connect the switch to the modem. (Sorry, couldn't find an image.) What are the pros and cons of these network layouts? Eg. in terms of reliability, security and flexibility? I am not a Linux guru but know of (and am not afraid of) iptables, dhcpd et al. Thank you for any tips, pointers and links.

    Read the article

  • Exclude an input language from Alt+Shift/Ctrl+Shift switching cycle on Windows

    - by Headcrab
    I have 3 input languages installed on my Windows 7: English, Russian and Japanese. So when I switch between them by Ctrl+Shift, they go like English - Russian - Japanese - English - ... I don't use Japanese much, but still need it occasionally. Is there a way to somehow exclude it from the "Ctrl+Shift cycle" without uninstalling it from the system? E. g. Ctrl+Shift will be like English - Russian - English - ..., while I still could switch to Japanese by a dedicated keyboard shortcut, say, Ctrl + 3? That extra Ctrl+Shift to go through Japanese just to switch between English and Russian is very annoying, and using Ctrl+1, Ctrl+2, Ctrl+3 for each input language isn't very ergonomic, either.

    Read the article

  • Pentium 4 Computer Won't Power Up

    - by Harvey
    I have a faulty Pentium 4 workstation with data that I would like to retrieve. Here are the symptoms & what I've done so far: Machine is totally dead. Motherboard LED is lit but that is the only sign of life. I have replaced the power supply and bypassed the on/off switch. Tried a PC Analyzer motherboard tester but didn't have any power to the card. Unpluggged the P4 cable from the motherboard, hit the on/off switch, the power supply fan comes on and I get codes from the analyzer but nothing that seems to be of any value. Machine does not boot. Will not shut down by hitting the switch. Bad motherboard or could it be a bad CPU cooling fan?

    Read the article

  • Intel hybrid graphics stuck in power save mode

    - by OZZIE
    I have an Asus UL30V with Intel hybrid graphics. When I bought it it used to switch to turn of the better graphics card to save power and run on a more power effecient one. When I connected the laptop to a power source again I could go to the intel graphics icon on the task bar and click on "switch to enhanced performance mode" or something similar. But like 2-3 months ago it suddenly vanished. I cannot switch modes anymore, it's gotten stuck in power save mode. I can change the windows power setting but that doesn't enable the better graphics card :( What should I do? I've tried restarting the computer and that does not work. I really hope I don't have to reinstall the drivers! It seems like other people have had the same issue: http://en.community.dell.com/support-forums/laptop/f/3518/p/19422695/19994601.aspx , he hasn't even got the same computer as me. I have windows 7 Home Premium x64 Any ideas?

    Read the article

  • How to fix unstable RJ45 jacks? [closed]

    - by BeemerGuy
    This is a little project I'm doing at home. I wanted to wire two rooms together (basically, the router is one room, and the switch is in the second room). So I ran a CAT5 between the two rooms, and wired an RJ45 jack in each room. I then hooked up the two jacks with two CAT5 cable to run it through the cable tester, and all 8 wires seem good. Now, when I connect the switch and the router, the connection is unstable -- I ping the router and it barely holds on for two pings before it disconnects, and stays in that unstable state. Just to make sure the router and the switch are ok, I connected them with long wire between the two rooms and the connection is absolutely stable, and pings continuously. What could be the cause for the unstable connection? Especially that it pings a few times, so there IS a connection. But why is it unstable? And how come the cable tester says it's ok, but it's unstable?

    Read the article

  • How do I change the NGINX user?

    - by danielfaraday
    I have a PHP script that creates a directory and outputs an image to the directory. This was working just fine under Apache but we recently decided to switch to NGINX to make more use of our limited RAM. I'm using the PHP mkdir() command to create the directory: mkdir(dirname($path['image']['server']), 0755, true); After the switch to NGINX, I'm getting the following warning: Warning: mkdir(): Permission denied in ... I've already checked all the permissions of the parent directories, so I've determined that I probably need to change the NGINX or PHP-FPM 'user' but I'm not sure how to do that (I never had to specify user permissions for APACHE). I can't seem to find much information on this. Any help would be great! (Note: Besides this little hang-up, the switch to NGINX has been pretty seamless; I'm using it for the first time and it literally only took about 10 minutes to get up and running with NGINX. Now I'm just ironing out the kinks.)

    Read the article

  • Is there any way I can add alternative key binding to a feature in compiz?

    - by vava
    I was wondering is there any way to add additional, alternative key binding to a particular feature in compiz? I am using Wall plugin and on my ThinkPad it is convenient to switch between horizontal workspaces with media buttons for browser navigation. But there just two of them, so I have to use completely different combinations to switch between workspaces vertically and that would very helpful if I can also use similar kind of combination to switch horizontally as well in addition to those media buttons. Is there a way maybe to send a message to the compiz to execute particular command? That would solve the issue.

    Read the article

  • bad switchs duplicate my ip

    - by tacoen
    I had a large area LAN. There were many switch and AP on it, then somehow I couldn't ping my servers, and it's said that the IP was duplicated. I use arpwatch and found out that one of the switch flip-flop-ing the IP. I isolated that troublesome switch using his mac-address. But, since this a large area LAN... I doubt this will be the last cases. If there any software or hardware that I can use to prevent this kind of error? Sorry for my bad English.

    Read the article

  • How to setup wireless radio to network using 2 nics?

    - by CptanPanic
    I am having problems setting up this network, hopefully someone can help me. Laptop <- Wireless Radio <- ... - Wireless Radio <- CPU1( NIC1,NIC2) <- SWITCH <- CPU2 I have a computer with 2 NICs (CPU1). One goes to a wireless radio that connects to a wireless laptop, the other NIC goes to network switch. I can't connect Wireless Radio to switch due to space constraints. All the machines and radios are on same network addresses. I tried using Window's Bridge network which did allow Laptop to reach CPU2, but not CPU1. What is the way to get this to work so all the computers can talk to each other?

    Read the article

  • Routing between two networks on linux?

    - by gGololicic
    I got stuck with one problem I cant find solution. I have linux pc with two NIC. first nic (eth1) is connected to public ip (probably switch or whatever, doesnt really mater) so eth1 is connected to wan and another eth0 that I connected to switch and make it a lan nic. configuration: eth1 ip address 88.200.1xx.xxx //xxx's are cuz of security reasons eth0 ip address 192.168.1.1 wan ------ [eth1 (linux PC) eth0]<----[switch]<---- [eth1 (PC1)] Now I want to connect this two networks, so PC1 can access linux PC and wan. I think I know how to do it but I cant confiugre it right. This is what I tried: I turend on ip forwarding (for sure) I set eth1 default gw to the right ip on the wan I tried to set eth0 default gw to the same ip (but i couldnt) What or how can I do this, I was trying with linux route command, but I got stuck. Please help.

    Read the article

  • netgear GS108TV2 RSTP configuration

    - by jhowland
    I have a large set of GS108TV2 units--my goal is to set up a network which is comprised of several loops for redundancy/fault tolerance. I have a minimal 3 switch loop configured, with RSTP enabled on two ports on each switch. I have my bridge max age set to 6, and my bridge forward delay set to 4, which are the minimum values allowed. Hello time is fixed at 2 seconds. The switches respond to a cable being removed from a socket, but it takes too long. I cannot get the switch to respond to a loss of connection on one of the redundant ports in less than 20 seconds. Is there any way to configure these switches to respond faster than 20 seconds? That is unacceptable for my application. thanks in advance for any help

    Read the article

  • Windows Remote Desktop with multiple monitors

    - by BDW
    I'm looking for a remote desktop product that will allow me to switch on the fly between how many monitors the desktop is using. This would be going from one Windows 7 machine to another, one is running Ultimate, the other Enterprise. I know I can use Windows RDP with multi-monitor support, but it seems that only allows me to use ALL monitors, and if I switch to a windowed view, I get huge scrollbars because I'm going from 3 monitors to 1 window. What I'm looking for is something that will allow me to switch from 1, 2, or 3 monitor displays without restarting the RDP and would end up with a true 1/2/3 display - ie, if I go from 3 monitors to 1, or a window, I don't get scrollbars. Is there any such product?

    Read the article

  • VMware vSwitches and spanning tree

    - by dunxd
    I have two redundant core switches I want to connect to a new vSwitch I am setting up on a VMware ESX host. The switch will have two physical NICs each of which will connect to one of the core switches. The core switches are connected. If this was a physical switch, I would worry about connecting it to both core switches, because this would create a network loop. Do I need to worry about this for a VMware virtual switch? VMware's documentation says it is not possible to connect two vSwitches in a loop, therefore STP is not required. However, I am worried about connecting two physical switches together via a vSwitch.

    Read the article

  • Will the VMs on the ESXi cluster be running after disconnection from the network?

    - by John
    What will happen if I disconnect the ESXi cluster configured with HA from the switch(I need to change the power source on the main switch) and there is no management port redundancy? I'm going to disable the host monitoring and VM monitoring within HA settings, and connect to the switch after it boots up. Will the virtual machines be running if I disconnect the hosts from the network so they will not see any other ESXi host? I hope everything will work fine and the hosts will join the cluster after they connect to the network again, but I would like to be sure ..

    Read the article

  • SQL SERVER – Update Statistics are Sampled By Default

    - by pinaldave
    After reading my earlier post SQL SERVER – Create Primary Key with Specific Name when Creating Table on Statistics, I have received another question by a blog reader. The question is as follows: Question: Are the statistics sampled by default? Answer: Yes. The sampling rate can be specified by the user and it can be anywhere between a very low value to 100%. Let us do a small experiment to verify if the auto update on statistics is left on. Also, let’s examine a very large table that is created and statistics by default- whether the statistics are sampled or not. USE [AdventureWorks] GO -- Create Table CREATE TABLE [dbo].[StatsTest]( [ID] [int] IDENTITY(1,1) NOT NULL, [FirstName] [varchar](100) NULL, [LastName] [varchar](100) NULL, [City] [varchar](100) NULL, CONSTRAINT [PK_StatsTest] PRIMARY KEY CLUSTERED ([ID] ASC) ) ON [PRIMARY] GO -- Insert 1 Million Rows INSERT INTO [dbo].[StatsTest] (FirstName,LastName,City) SELECT TOP 1000000 'Bob', CASE WHEN ROW_NUMBER() OVER (ORDER BY a.name)%2 = 1 THEN 'Smith' ELSE 'Brown' END, CASE WHEN ROW_NUMBER() OVER (ORDER BY a.name)%10 = 1 THEN 'New York' WHEN ROW_NUMBER() OVER (ORDER BY a.name)%10 = 5 THEN 'San Marino' WHEN ROW_NUMBER() OVER (ORDER BY a.name)%10 = 3 THEN 'Los Angeles' ELSE 'Houston' END FROM sys.all_objects a CROSS JOIN sys.all_objects b GO -- Update the statistics UPDATE STATISTICS [dbo].[StatsTest] GO -- Shows the statistics DBCC SHOW_STATISTICS ("StatsTest"PK_StatsTest) GO -- Clean up DROP TABLE [dbo].[StatsTest] GO Now let us observe the result of the DBCC SHOW_STATISTICS. The result shows that Resultset is for sure sampling for a large dataset. The percentage of sampling is based on data distribution as well as the kind of data in the table. Before dropping the table, let us check first the size of the table. The size of the table is 35 MB. Now, let us run the above code with lesser number of the rows. USE [AdventureWorks] GO -- Create Table CREATE TABLE [dbo].[StatsTest]( [ID] [int] IDENTITY(1,1) NOT NULL, [FirstName] [varchar](100) NULL, [LastName] [varchar](100) NULL, [City] [varchar](100) NULL, CONSTRAINT [PK_StatsTest] PRIMARY KEY CLUSTERED ([ID] ASC) ) ON [PRIMARY] GO -- Insert 1 Hundred Thousand Rows INSERT INTO [dbo].[StatsTest] (FirstName,LastName,City) SELECT TOP 100000 'Bob', CASE WHEN ROW_NUMBER() OVER (ORDER BY a.name)%2 = 1 THEN 'Smith' ELSE 'Brown' END, CASE WHEN ROW_NUMBER() OVER (ORDER BY a.name)%10 = 1 THEN 'New York' WHEN ROW_NUMBER() OVER (ORDER BY a.name)%10 = 5 THEN 'San Marino' WHEN ROW_NUMBER() OVER (ORDER BY a.name)%10 = 3 THEN 'Los Angeles' ELSE 'Houston' END FROM sys.all_objects a CROSS JOIN sys.all_objects b GO -- Update the statistics UPDATE STATISTICS [dbo].[StatsTest] GO -- Shows the statistics DBCC SHOW_STATISTICS ("StatsTest"PK_StatsTest) GO -- Clean up DROP TABLE [dbo].[StatsTest] GO You can see that Rows Sampled is just the same as Rows of the table. In this case, the sample rate is 100%. Before dropping the table, let us also check the size of the table. The size of the table is less than 4 MB. Let us compare the Result set just for a valid reference. Test 1: Total Rows: 1000000, Rows Sampled: 255420, Size of the Table: 35.516 MB Test 2: Total Rows: 100000, Rows Sampled: 100000, Size of the Table: 3.555 MB The reason behind the sample in the Test1 is that the data space is larger than 8 MB, and therefore it uses more than 1024 data pages. If the data space is smaller than 8 MB and uses less than 1024 data pages, then the sampling does not happen. Sampling aids in reducing excessive data scan; however, sometimes it reduces the accuracy of the data as well. Please note that this is just a sample test and there is no way it can be claimed as a benchmark test. The result can be dissimilar on different machines. There are lots of other information can be included when talking about this subject. I will write detail post covering all the subject very soon. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, SQL, SQL Authority, SQL Index, SQL Optimization, SQL Performance, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, T SQL, Technology Tagged: SQL Statistics

    Read the article

  • On mobile is there a reason why processes are often short lived and must persist their state explicitly?

    - by Alexandre Jasmin
    Most mobile platforms (such as Android, iOS, Windows phone 7 and I believe the new WinRT) can kill inactive application processes under memory pressure. To prevent this from affecting the user experience applications are expected to save and restore their state as their process is killed and restarted. Having application processes killed in this way makes the developers job harder. On various occasions I've seen a mobile app that would: Return to the welcome screen each time I switch back to it. Crash when I switch back to it (possibly accessing some state that no longer exists after the process was killed) Misbehave when I switch back to it (sometimes requiring a restart or tasks killer to fix) Otherwise misbehave in some hard to reproduce way (e.g. android service killed and restarted at the wrong time) I don't really understand why these mobile operating systems are designed to kill tasks in this way especially since it makes application development more difficult and error prone. Desktop operating systems don't kill processes like that. They swap out unused pages of memory to mass storage. Is there a reason why the same approach isn't used on mobile? Mobile hardware is only a few years behind PC hardware in term of performance. I'm sure there are very good reasons why mobile operating systems are designed this way. If you can point me to a paper or blog post that explain these reasons or can give me some insight I'd very much appreciate it.

    Read the article

  • Post build events using ROBOCOPY instead of XCOPY

    - by Vizioz Limited
    I don't know about you, but for a long time I have used XCOPY statements in my Visual Studio post build events to copy my Umbraco files from the project folders to the local version of the website associated with the project.For the last few months we have been building a website framework for a client, who has subsequently sold the site to 5 clients, each with a different skin and some variations in their functional requirements.So, we now have a single source solutions, that builds and copies the site files into 5 seperate local websites, which enables us to easily test them all, what we had found was that this process was starting to slow up our build process and was reaching 30-45 seconds on a high spec Quad core machine (and slower on others)Today I asked Colin to create seperate Solution Configurations within Visual Studio so that while we were developing we could target a single site, and when we wanted to test all sites, we could target "ALL" and the Post Build script would then copy the files to all sites.This worked well, and with a couple of other optimisations, our build was now taking about 10 seconds for a single site.Then Colin came across ROBOCOPY and suggested that maybe this would be a suitable alternative to XCOPY, well, I had not heard of it.. (shock horror some of you shout, some I am sure like me, are also wondering what it is!)ROBOCOPY is new in Windows Vista & Windows 7 (you can also download it for XP & Windows 2003) and it has a lot of additional features, the two that were most interesting to us were:/MIR = Mirror a folder tree/XD = Exclude Directories/NP = No Progress (i.e. it does not give you a chart of it's results, which just fills up your Output window!)So, we set about implementing ROBOCOPY, we decided to use the /MIR switch on all folders that we knew were always stored in our project folders:- images- css- masterpages- xsltAnd for other files we just used the straight robocopy functionality.We also decided to exclude all the .SVN directories using the /XD switch and finally we added the /NP switch as mentioned above.The beauty of all of this, is the /MIR functionality, as this means that only files that have changed will be copied across which greatly speeds up the process, especially on the images folders which previously copied across on every build, now, if we add a new image to the project it will be copied across automatically and then never again, unless we change it of course!The build time now for all sites is approximately 4 seconds and for a single site, 2 seconds, I would highly recommend the time to make the same optimisations to your build processes if you have not done so already.

    Read the article

  • What's up with LDoms: Part 1 - Introduction & Basic Concepts

    - by Stefan Hinker
    LDoms - the correct name is Oracle VM Server for SPARC - have been around for quite a while now.  But to my surprise, I get more and more requests to explain how they work or to give advise on how to make good use of them.  This made me think that writing up a few articles discussing the different features would be a good idea.  Now - I don't intend to rewrite the LDoms Admin Guide or to copy and reformat the (hopefully) well known "Beginners Guide to LDoms" by Tony Shoumack from 2007.  Those documents are very recommendable - especially the Beginners Guide, although based on LDoms 1.0, is still a good place to begin with.  However, LDoms have come a long way since then, and I hope to contribute to their adoption by discussing how they work and what features there are today.  In this and the following posts, I will use the term "LDoms" as a common abbreviation for Oracle VM Server for SPARC, just because it's a lot shorter and easier to type (and presumably, read). So, just to get everyone on the same baseline, lets briefly discuss the basic concepts of virtualization with LDoms.  LDoms make use of a hypervisor as a layer of abstraction between real, physical hardware and virtual hardware.  This virtual hardware is then used to create a number of guest systems which each behave very similar to a system running on bare metal:  Each has its own OBP, each will install its own copy of the Solaris OS and each will see a certain amount of CPU, memory, disk and network resources available to it.  Unlike some other type 1 hypervisors running on x86 hardware, the SPARC hypervisor is embedded in the system firmware and makes use both of supporting functions in the sun4v SPARC instruction set as well as the overall CPU architecture to fulfill its function. The CMT architecture of the supporting CPUs (T1 through T4) provide a large number of cores and threads to the OS.  For example, the current T4 CPU has eight cores, each running 8 threads, for a total of 64 threads per socket.  To the OS, this looks like 64 CPUs.  The SPARC hypervisor, when creating guest systems, simply assigns a certain number of these threads exclusively to one guest, thus avoiding the overhead of having to schedule OS threads to CPUs, as do typical x86 hypervisors.  The hypervisor only assigns CPUs and then steps aside.  It is not involved in the actual work being dispatched from the OS to the CPU, all it does is maintain isolation between different guests. Likewise, memory is assigned exclusively to individual guests.  Here,  the hypervisor provides generic mappings between the physical hardware addresses and the guest's views on memory.  Again, the hypervisor is not involved in the actual memory access, it only maintains isolation between guests. During the inital setup of a system with LDoms, you start with one special domain, called the Control Domain.  Initially, this domain owns all the hardware available in the system, including all CPUs, all RAM and all IO resources.  If you'd be running the system un-virtualized, this would be what you'd be working with.  To allow for guests, you first resize this initial domain (also called a primary domain in LDoms speak), assigning it a small amount of CPU and memory.  This frees up most of the available CPU and memory resources for guest domains.  IO is a little more complex, but very straightforward.  When LDoms 1.0 first came out, the only way to provide IO to guest systems was to create virtual disk and network services and attach guests to these services.  In the meantime, several different ways to connect guest domains to IO have been developed, the most recent one being SR-IOV support for network devices released in version 2.2 of Oracle VM Server for SPARC. I will cover these more advanced features in detail later.  For now, lets have a short look at the initial way IO was virtualized in LDoms: For virtualized IO, you create two services, one "Virtual Disk Service" or vds, and one "Virtual Switch" or vswitch.  You can, of course, also create more of these, but that's more advanced than I want to cover in this introduction.  These IO services now connect real, physical IO resources like a disk LUN or a networt port to the virtual devices that are assigned to guest domains.  For disk IO, the normal case would be to connect a physical LUN (or some other storage option that I'll discuss later) to one specific guest.  That guest would be assigned a virtual disk, which would appear to be just like a real LUN to the guest, while the IO is actually routed through the virtual disk service down to the physical device.  For network, the vswitch acts very much like a real, physical ethernet switch - you connect one physical port to it for outside connectivity and define one or more connections per guest, just like you would plug cables between a real switch and a real system. For completeness, there is another service that provides console access to guest domains which mimics the behavior of serial terminal servers. The connections between the virtual devices on the guest's side and the virtual IO services in the primary domain are created by the hypervisor.  It uses so called "Logical Domain Channels" or LDCs to create point-to-point connections between all of these devices and services.  These LDCs work very similar to high speed serial connections and are configured automatically whenever the Control Domain adds or removes virtual IO. To see all this in action, now lets look at a first example.  I will start with a newly installed machine and configure the control domain so that it's ready to create guest systems. In a first step, after we've installed the software, let's start the virtual console service and downsize the primary domain.  root@sun # ldm list NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-c-- UART 512 261632M 0.3% 2d 13h 58m root@sun # ldm add-vconscon port-range=5000-5100 \ primary-console primary root@sun # svcadm enable vntsd root@sun # svcs vntsd STATE STIME FMRI online 9:53:21 svc:/ldoms/vntsd:default root@sun # ldm set-vcpu 16 primary root@sun # ldm set-mau 1 primary root@sun # ldm start-reconf primary root@sun # ldm set-memory 7680m primary root@sun # ldm add-config initial root@sun # shutdown -y -g0 -i6 So what have I done: I've defined a range of ports (5000-5100) for the virtual network terminal service and then started that service.  The vnts will later provide console connections to guest systems, very much like serial NTS's do in the physical world. Next, I assigned 16 vCPUs (on this platform, a T3-4, that's two cores) to the primary domain, freeing the rest up for future guest systems.  I also assigned one MAU to this domain.  A MAU is a crypto unit in the T3 CPU.  These need to be explicitly assigned to domains, just like CPU or memory.  (This is no longer the case with T4 systems, where crypto is always available everywhere.) Before I reassigned the memory, I started what's called a "delayed reconfiguration" session.  That avoids actually doing the change right away, which would take a considerable amount of time in this case.  Instead, I'll need to reboot once I'm all done.  I've assigned 7680MB of RAM to the primary.  That's 8GB less the 512MB which the hypervisor uses for it's own private purposes.  You can, depending on your needs, work with less.  I'll spend a dedicated article on sizing, discussing the pros and cons in detail. Finally, just before the reboot, I saved my work on the ILOM, to make this configuration available after a powercycle of the box.  (It'll always be available after a simple reboot, but the ILOM needs to know the configuration of the hypervisor after a power-cycle, before the primary domain is booted.) Now, lets create a first disk service and a first virtual switch which is connected to the physical network device igb2. We will later use these to connect virtual disks and virtual network ports of our guest systems to real world storage and network. root@sun # ldm add-vds primary-vds root@sun # ldm add-vswitch net-dev=igb2 switch-primary primary You are free to choose whatever names you like for the virtual disk service and the virtual switch.  I strongly recommend that you choose names that make sense to you and describe the function of each service in the context of your implementation.  For the vswitch, for example, you could choose names like "admin-vswitch" or "production-network" etc. This already concludes the configuration of the control domain.  We've freed up considerable amounts of CPU and RAM for guest systems and created the necessary infrastructure - console, vts and vswitch - so that guests systems can actually interact with the outside world.  The system is now ready to create guests, which I'll describe in the next section. For further reading, here are some recommendable links: The LDoms 2.2 Admin Guide The "Beginners Guide to LDoms" The LDoms Information Center on MOS LDoms on OTN

    Read the article

  • How To Disable Loading Of Images In Chrome, Firefox and IE

    - by Gopinath
    Many of us find the necessity to disable loading images in web browsers for various reasons. May be when we are at work place, we don’t our boss to notice flashy browser window or we are connected to low bandwidth connections like GPRS which works faster without images. What ever may be the reason, here are the tips to disable images in Google Chrome, Firefox and Internet Explorer web browsers. Google Chrome – Disable Loading Images To disable loading of images in Google Chrome 1. Click on Tools Icon and choose Options menu item 2. In Google Chrome Options dialog window, switch to the tab Under the hood and click on the button Content Settings 3. Select Images from the list of options available in the left panel and choose the option Do not show any images 4. Close dialog windows and you are done. Firefox – Disable Loading Images To disable loading of images in Firefox 1. Open Firefox 2. Go to Tools -> Options 3. Switch to Content tab 4. Uncheck the option Load images automatically Internet Explorer – Disable Loading Images To disable loading of images in Internet Explorer 1. Launch Internet Explorer 2. Go to Tools -> Internet Options 3. Switch to Advanced tab 4. Uncheck the option Show pictures under Multimedia category cc image credit: flickr/indoloony This article titled,How To Disable Loading Of Images In Chrome, Firefox and IE, was originally published at Tech Dreams. Grab our rss feed or fan us on Facebook to get updates from us.

    Read the article

  • Setting up shared connection

    - by Calvin Froedge
    I have a network that is connected to the internet via a switch connected to a router. I have it setup like this so I can work on the new network without causing problems on the old. Anyway, I'm trying to enable internet connection sharing. Internet comes to server like this: Modem - Router - Switch - Ubuntu 11.10 (Eth0) I want to share the connection through Eth1 (Eth1 - Managed Switch - Clients). Here is my config for /etc/network/interfaces: I have a DHCP server running on Eth1. Here is my config: ddns-update-style none; option domain-name "myserver.local"; option domain-name-servers 192.168.1.2, 8.8.8.8; default-lease-time 600; max-lease-time 7200; authoritative; subnet 192.168.1.0 netmask 255.255.255.0 { interface eth1; range 192.168.1.3 192.168.1.254; option routers 192.168.1.1; option subnet-mask 255.255.255.0; option broadcast-address 192.168.1.255; } Here is /etc/network/interfaces: # The loopback network interface auto lo iface lo inet loopback # The primary network interface auto eth0 iface eth0 inet dhcp #Used for internal network auto eth1 iface eth1 inet static address 192.168.1.2 netmask 255.255.255.0 broadcast 192.168.1.255 network 192.168.1.0 Here is /etc/hosts: 127.0.0.1 localhost 127.0.1.1 myserver.isp.com server 192.168.1.2 server.myserver.local server myserver.local In /etc/sysctl.conf, I've set the following: net.ipv4.ip_forward=1 Finally, in /etc/rc.local, I've set the following: /sbin/iptables -P FORWARD ACCEPT /sbin/iptables --table nat -A POSTROUTING -o eth1 -j MASQUERADE When I ping 8.8.8.8 (google's DNS) from a client that is authenticated with my DHCP server (they have been assigned a local ip, like 192.168.1.10), I get a timeout. How can I debug this further to figure out where my problem is?

    Read the article

  • Generate a merge statement from table structure

    - by Nigel Rivett
    This code generates a merge statement joining on he natural key and checking all other columns to see if they have changed. The full version deals with type 2 processing and an audit trail but this version is useful. Just the insert or update part is handy too. Change the table at the top (spt_values in master in the version) and the join columns for the merge in @nk. The output generated is at the top and the code to run to generate it below. Output merge spt_values a using spt_values b on a.name = b.name and a.number = b.number and a.type = b.type when matched and (1=0 or (a.low b.low) or (a.low is null and b.low is not null) or (a.low is not null and b.low is null) or (a.high b.high) or (a.high is null and b.high is not null) or (a.high is not null and b.high is null) or (a.status b.status) or (a.status is null and b.status is not null) or (a.status is not null and b.status is null) ) then update set low = b.low , high = b.high , status = b.status when not matched by target then insert ( name , number , type , low , high , status ) values ( b.name , b.number , b.type , b.low , b.high , b.status ); Generator set nocount on declare @t varchar(128) = 'spt_values' declare @i int = 0 -- this is the natural key on the table used for the merge statement join declare @nk table (ColName varchar(128)) insert @nk select 'Number' insert @nk select 'Name' insert @nk select 'Type' declare @cols table (seq int, nkseq int, type int, colname varchar(128)) ;with cte as ( select ordinal_position, type = case when columnproperty(object_id(@t), COLUMN_NAME,'IsIdentity') = 1 then 3 when nk.ColName is not null then 1 else 0 end, COLUMN_NAME from information_schema.columns c left join @nk nk on c.column_name = nk.ColName where table_name = @t ) insert @cols (seq, nkseq, type, colname) select ordinal_position, row_number() over (partition by type order by ordinal_position) , type, COLUMN_NAME from cte declare @result table (i int, j int, k int, data varchar(500)) select @i = @i + 1 insert @result (i, data) select @i, 'merge ' + @t + ' a' select @i = @i + 1 insert @result (i, data) select @i, ' using cte b' select @i = @i + 1 insert @result (i, j, data) select @i, nkseq, ' ' + case when nkseq = 1 then 'on' else 'and' end + ' a.' + ColName + ' = b.' + ColName from @cols where type = 1 select @i = @i + 1 insert @result (i, data) select @i, ' when matched and (1=0' select @i = @i + 1 insert @result (i, j, k, data) select @i, seq, 1, ' or (a.' + ColName + ' b.' + ColName + ')' + ' or (a.' + ColName + ' is null and b.' + ColName + ' is not null)' + ' or (a.' + ColName + ' is not null and b.' + ColName + ' is null)' from @cols where type 1 select @i = @i + 1 insert @result (i, data) select @i, ' )' select @i = @i + 1 insert @result (i, data) select @i, ' then update set' select @i = @i + 1 insert @result (i, j, data) select @i, nkseq, ' ' + case when nkseq = 1 then ' ' else ', ' end + colname + ' = b.' + colname from @cols where type = 0 select @i = @i + 1 insert @result (i, data) select @i, ' when not matched by target then insert' select @i = @i + 1 insert @result (i, data) select @i, ' (' select @i = @i + 1 insert @result (i, j, data) select @i, seq, ' ' + case when seq = 1 then ' ' else ', ' end + colname from @cols where type 3 select @i = @i + 1 insert @result (i, data) select @i, ' )' select @i = @i + 1 insert @result (i, data) select @i, ' values' select @i = @i + 1 insert @result (i, data) select @i, ' (' select @i = @i + 1 insert @result (i, j, data) select @i, seq, ' ' + case when seq = 1 then ' ' else ', ' end + 'b.' + colname from @cols where type 3 select @i = @i + 1 insert @result (i, data) select @i, ' );' select data from @result order by i,j,k,data

    Read the article

  • In Ubuntu 13.10, none of the hotkeys of LibreOffice works in non-English keyboard layout

    - by maqtanim
    In Ubuntu 13.10, the hotkeys/shortcut-keys (Ctrl+b, Ctrl+s etc) in LibreOffice are language dependent and work in English language only. While writing in any other language (i.e. any Cyrillic and/or any Bengali etc) it's impossible to use hotkeys, they just don't do anything. Switching to English input language enable hotkeys once again. This is very frustrating as user needs to switch language to save document, to make it bold, or italic, etc. This was not experienced in Ubuntu 13.04. Steps to reproduce: System Settings Text Entry. Add another keyboard layout beside English [In my case it is Bengali (Probhat)] Now launch Writer. Switch the keyboard layout from English (US) to Bengali (Probhat) by pressing Ctrl+Space. Press Ctrl+B to change font weight to bold. Error: Font weight does not get changed. Expected: Font weight should change to bold. Note: none other system hotkeys work as expected. I.e. Ctrl+s to save, or Ctrl+b to subscript, or Ctrl+i to italic etc. Workaround: The only way is to - change the keyboard layout to English then press desired hotkey then switch keyboard layout back to Bengali. The issue is critical, as it make writer very slow for keyboard-only typing.

    Read the article

  • BizTalk 2009 - The Community ODBC Adapter: Schema Generation

    - by Stuart Brierley
    Having previously detailed the installation of the Community ODBC Adapter for BizTalk 2009, the next thing I will be looking at is the generation of schemas using this ODBC adapter. Within your BizTalk 2009 project, right click the project and select Add Generated Items.  In the resultant window choose Add Adapter Metadata and click Add to open the Add Adapter Wizard. Check that the BizTalk Server and Database names are correct, select the ODBC adapter and click next. You must now set the connection string. To start with choose set, then new DSN (data source name). You now need to define the Data Source you will be connecting to.  On the User DSN tab select Add add then driver you want to use. In this case I am going to use the MySQL ODBC Driver.  A User DSN will only be visible on the current machine with you as a user. * Although I initially set up a User DSN and this was fine for creating schemas with, I later realised that you actually need a system DSN as the BizTalk host service needs this to be able connect to the database on a receive or send port. You will then be asked to Set up the MySQL ODBC Data Source.  In my case this is a local database making use of named pipes, so I had to make sure that I ticked the "Force use of named pipes" check box and removed the "# The Pipe the MySQL Server will use socket=mysql" line from the mysql.ini; with this is place the connection would fail as there is no apparent way to specify the pipe name in the ODBC driver configuration. This will then update the User DSN tab with the new Data Source.  Make sure that you select it and press OK. Select it again in the Choose Data Source window and press OK.  On the ODBC transport window select next. You will now be presented with the Schema Information window, where you must supply the namespace, type and root element names for your schema. Next choose the type of statement that you will be using to create your schema - in this case I am using a stored procedure. *I later discovered that this option is fine for MySQL stored procedures without input parameters, but failed for MySQL stored procedures with input parameters.  (I will be posting on the way to handle input parameters soon) Next you will need to specify the name of the stored procedure.  In this case I have a simple stored procedure to return all the data held by my TestTable in MySQL. Select * from TestTable; The table itself has three columns: Name, Sex and Married. Selecting finish should now hopefully create your schemas based on the input and output from your stored procedure. In my case I have:   An empty schema for the request; after all I have no parameters for the stored procedure.  A response schema comprised of a Table Record with Name, Sex and Married children. Next I will be looking at the use of the ODBC adpater with: Receive ports Send ports

    Read the article