  • Backtrack, Wi-Fi not working

    - by hradecek
    I've installed Backtrack 5R3 KDE, and I realized that my wireless is not working, but wired is working fine. Here's the lshw output: *-network description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:02:00.0 logical name: eth0 version: 05 serial: 04:7d:7b:b7:46:f8 size: 100MB/s capacity: 100MB/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl_nic/rtl8105e-1.fw ip=192.168.2.2 latency=0 link=yes multicast=yes port=MII speed=100MB/s resources: irq:42 ioport:2000(size=256) memory:f0404000-f0404fff memory:f0400000-f0403fff lspci output: 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) 00:14.0 USB Controller: Intel Corporation Panther Point USB xHCI Host Controller (rev 04) 00:16.0 Communication controller: Intel Corporation Panther Point MEI Controller #1 (rev 04) 00:1a.0 USB Controller: Intel Corporation Panther Point USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation Panther Point High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 1 (rev c4) 00:1c.1 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 2 (rev c4) 00:1d.0 USB Controller: Intel Corporation Panther Point USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation Panther Point LPC Controller (rev 04) 00:1f.2 SATA controller: Intel Corporation Panther Point 6 port SATA AHCI Controller (rev 04) 00:1f.3 SMBus: Intel Corporation Panther Point SMBus Controller (rev 04) 02:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8101E/RTL8102E PCI Express Fast Ethernet controller (rev 05)

    Read the article

  • Access an external SSH server through a restrictive proxy [on hold]

    - by Cyrille
    I'm a software developer. I wish to access my computer at home through SSH. For example, I sometime need to access my personal projects source code to check how I handled specific problems. Unfortunately, I currently work under an over-restrictive and anti-productive proxy that waste a hell of a lot of everyone's time (We often have to visit websites from our smartphones or use a web proxy to check very legitimates websites for answers, and don't get me started on other "security" overkill features we have to cope with...). Well, back to the subject, I can access my home computer from my phone (SSH, port 22 and 80 both redirected by router on port 22). It works, but it's quite uncomfortable. From my office computer, this is what I tried so far: export http_proxy=http://user:pass@proxyip:8080 echo "user:pass" > ~/.corkscrew-auth echo "ProxyCommand corkscrew proxyip 8080 %h %p /home/me/.corkscrew-auth" > ~/.ssh/config ssh 82.23.34.56 -l me -p 80 Proxy could not open connnection to 82.23.34.56: Forbidden ssh_exchange_identification: Connection closed by remote host (same without -p 80) Without corkscrew: ssh: connect to host 82.23.34.56 port 80: Connection timed out ssh: connect to host 82.23.34.56 port 22: Connection timed out Any other idea ?

    Read the article

  • Help with routing table

    - by user68752
    I have tried to find the answer to my question but not really found a clean and easy solution. I have a box (Ubuntu headless 10.04.1 server, with one Ethernet port) on LAN behind a router (running m0n0wall), that I have successfully installed a PPTP device (ppp0) on, this is working flawlessly (following this link) The thing is I want this box to route all it's internet traffic through the VPN tunnel (ppp0 device) but also being able to access the local LAN on 192.168.1.* subnet. I've succeeded a bit with this, but my problem right now is that I have port forwards (e.g. SSH) done in the m0n0wall pointing to this specific box which forces me to do "add routes" to all boxes that want to access this machine through this specific port. For instance a machine with ip xyz.xyz.xyz.xyz needs to have a static route setup in the routing table on the box to be able to access the box. This is the result of route -n xxx.xxx.137.2 192.168.1.1 255.255.255.255 UGH 0 0 0 eth0 xxx.xxx.137.2 0.0.0.0 255.255.255.255 UH 0 0 0 ppp0 192.168.1.0 0.0.0.0 255.255.255.0 U 0 0 0 eth0 yyy.yyy.0.0 192.168.1.1 255.255.0.0 UG 0 0 0 eth0 0.0.0.0 0.0.0.0 0.0.0.0 U 0 0 0 ppp0 Where xxx is the IPs provided from VPN server. yyy.yyy.0.0 is a net that i want to have access to the box, without this I can't access the box from outside the LAN (via port-forwards done in router software, m0n0wall) is there away round this ugly solution?

    Read the article

  • Best way to patch (8) RJ45 ports from one room to another.

    - by zimmer62
    I have a 48 port patch panel in my basement, which I've wired almost all of them to various rooms around the house. Many are not actually being used at the moment, but pretty much all of them are wired to somewhere. As of recent, I've put in an HTPC in my media closet (different room), and I'm finding I need a lot more RJ45 plugs to this area. I have 4 drops here, and adding a switch will not solve my problems. I'm using the cabling for other things such as IR and Serial devices, not just Ethernet. What I'm hoping to do is add an 8 port panel in that media closet, and tie those into an 8 port panel on my rack next to the 48 port... What I don't want to do is pull 8 separate cables one by one from one area to the other unless someone has a technique that will allow me to do that quickly, and painlessly. Do they make cables with more conductors specifically for this purpose? Or patch panels that are designed for a special cable essentially just extending ports from one room to another?

    Read the article

  • Can not connect remotely to MySQL Server on Ubuntu 10.10

    - by BobFranz
    Ok I have searched google for two days trying to get this to work. Here are the steps I have taken so far: Clean install of Ubuntu 10.10 Install mysql 5.1 as well as admin Comment out the bind address in the config file Create a new database Create a new user that is username@% to allow remote connections Grant all access to this user to the new database EXCEPT the grant option Login on the server is ok using this new user and database on the localhost Login on the server is ok using this new user and database on the server internal network ip Login from a remote computer is ok using this new user and database using the internal network ip Login is not working when logging in with this username and database using the external ip address from the server or the remote computer. I have port forwarding enabled for this port and it is viewable from outside as confirmed by canyouseeme.org I have nmap'd using the following command on the internal ip and get the below result: nmap -PN -p 3306 192.168.1.73 Starting Nmap 5.21 ( http://nmap.org ) at 2011-02-19 13:41 PST Nmap scan report for computername-System-Name (192.168.1.73) Host is up (0.00064s latency). PORT STATE SERVICE 3306/tcp open mysql Nmap done: 1 IP address (1 host up) scanned in 0.23 seconds I have nmap'd using the following command on the internal ip and get the below result(I have hidden ip for obvious reasons): nmap -PN -p 3306 xxx.xxx.xx.xxx Starting Nmap 5.21 ( http://nmap.org ) at 2011-02-19 13:42 PST Nmap scan report for HOSTNAME (xxx.xxx.xx.xxx) Host is up (0.00056s latency). PORT STATE SERVICE 3306/tcp closed mysql Nmap done: 1 IP address (1 host up) scanned in 0.21 seconds I am completely stuck here and need some help. I have tried everything under the moon and still can not connect from a remote external ip address. Any help is greatly appreciated and I need to do anything to help find the problem let me know and I will post the results here.

    Read the article

  • How to start and stop a systemd unit with another?

    - by Andy Shinn
    I am using CoreOS to schedule systemd units with fleet. I have two units (firehose.service and firehose-announce.service. I am trying to get the firehose-announce.service to start and stop along with the firehose.service. Here is the unit file for firehose-announce.service: [Unit] Description=Firehose etcd announcer BindsTo=firehose@%i.service After=firehose@%i.service Requires=firehose@%i.service [Service] EnvironmentFile=/etc/environment TimeoutStartSec=30s ExecStartPre=/bin/sh -c 'sleep 1' ExecStart=/bin/sh -c "port=$(docker inspect -f '{{range $i, $e := .NetworkSettings.Ports }}{{$p := index $e 0}}{{$p.HostPort}}{{end}}' firehose-%i); echo -n \"Adding socket $COREOS_PRIVATE_IPV4:$port/tcp to /firehose/upstream/firehose-%i\"; while netstat -lnt | grep :$port >/dev/null; do etcdctl set /firehose/upstream/firehose-%i $COREOS_PRIVATE_IPV4:$port --ttl 300 >/dev/null; sleep 200; done" RestartSec=30s Restart=on-failure [X-Fleet] X-ConditionMachineOf=firehose@%i.service I am trying to use BindsTo with the notion that start and stop of firehose.service will also start or stop firehose-announce.service. But this never happens correctly. If firehose.service is stopped, then firehose-announce.service goes to failed state. But when I start firehose.service, the firehose-announce.service doesn't start up. What am I doing wrong here?

    Read the article

  • Having an issue trying to get Gigabit speed across my network (Ubuntu Server)

    - by user94217
    I've just started looking into the network speeds at my office, the entire network is setup to be "Gigabit". This includes Gb switches, Gb Network cards and Cat 5e cabling. I'm not expecting the full speed, I just want more than ~90 Mb/s. I've been running some tests with iperf the linux tools and checking the hardware with ethtool. I have 3 servers and when doing my checks/test I discovered that the two backup servers can access each other at around 450 Mb/s but when using either one of them to connect and test the main server, I only get the 90Mb/s even though ethtool shows the networking card running at 1000/Full. The only difference between all the server/networking cards is the "Port" which ethtool shows. On the two backup servers the "Port" is shown as MII yet on the other it's shown as "Twisted Pair". When using ethtool -s to manually set the "Port" to MII on the main server, it looses all connectivity and does not show "Speed" or "Duplex". Anyway, Am i doing something wrong? Is there a specific reason my main server cannot use Gb when there appears to be no difference except the "Port"?

    Read the article

  • A server which uses 2 IPs and is needed to give service (under NAT)

    - by user6004
    I have an internal server, which uses a certain service. This service listens on a port, and speaks on a different port. The problem with the service is that it can't listen and speak on the same IP address, so I have configured 2 IP addresses for that NIC, and so I "solved" the problem with the listening and speaking. I have a problem though... I need that server to be NATed, with a public IP address, and that server needs to be available from the outside (and as only one IP)... The question is, how do I solve the situation here? If I do a NAT for one IP address (the listening port), then he will be able to get requests from the outside, but won't be able to send out traffic (because the other IP won't have NAT). If I do NAT on both of the IPs, then when traffic comes in for the listening port, it won't necessarily arrive to the listening IP, but rather to the speaking one. I hope I made myself clear and that there is a sensible solution here that I am missing.

    Read the article

  • ERROR: Linux route add command failed: external program exited with error status: 4

    - by JohnMerlino
    A remote machine running fedora uses openvpn, and multiple developers were successfully able to connect to it via their client openvpn. However, I am running Ubuntu 12.04 and I am having trouble connecting to the server via vpn. I copied ca.crt, home.key, and home.crt from the server to my local machine to /etc/openvpn folder. My client.conf file looks like this: ############################################## # Sample client-side OpenVPN 2.0 config file # # for connecting to multi-client server. # # # # This configuration can be used by multiple # # clients, however each client should have # # its own cert and key files. # # # # On Windows, you might want to rename this # # file so it has a .ovpn extension # ############################################## # Specify that we are a client and that we # will be pulling certain config file directives # from the server. client # Use the same setting as you are using on # the server. # On most systems, the VPN will not function # unless you partially or fully disable # the firewall for the TUN/TAP interface. ;dev tap dev tun # Windows needs the TAP-Win32 adapter name # from the Network Connections panel # if you have more than one. On XP SP2, # you may need to disable the firewall # for the TAP adapter. ;dev-node MyTap # Are we connecting to a TCP or # UDP server? Use the same setting as # on the server. ;proto tcp proto udp # The hostname/IP and port of the server. # You can have multiple remote entries # to load balance between the servers. remote xx.xxx.xx.130 1194 ;remote my-server-2 1194 # Choose a random host from the remote # list for load-balancing. Otherwise # try hosts in the order specified. ;remote-random # Keep trying indefinitely to resolve the # host name of the OpenVPN server. Very useful # on machines which are not permanently connected # to the internet such as laptops. resolv-retry infinite # Most clients don't need to bind to # a specific local port number. nobind # Downgrade privileges after initialization (non-Windows only) ;user nobody ;group nogroup # Try to preserve some state across restarts. persist-key persist-tun # If you are connecting through an # HTTP proxy to reach the actual OpenVPN # server, put the proxy server/IP and # port number here. See the man page # if your proxy server requires # authentication. ;http-proxy-retry # retry on connection failures ;http-proxy [proxy server] [proxy port #] # Wireless networks often produce a lot # of duplicate packets. Set this flag # to silence duplicate packet warnings. ;mute-replay-warnings # SSL/TLS parms. # See the server config file for more # description. It's best to use # a separate .crt/.key file pair # for each client. A single ca # file can be used for all clients. ca ca.crt cert home.crt key home.key # Verify server certificate by checking # that the certicate has the nsCertType # field set to "server". This is an # important precaution to protect against # a potential attack discussed here: # http://openvpn.net/howto.html#mitm # # To use this feature, you will need to generate # your server certificates with the nsCertType # field set to "server". The build-key-server # script in the easy-rsa folder will do this. ns-cert-type server # If a tls-auth key is used on the server # then every client must also have the key. ;tls-auth ta.key 1 # Select a cryptographic cipher. # If the cipher option is used on the server # then you must also specify it here. ;cipher x # Enable compression on the VPN link. # Don't enable this unless it is also # enabled in the server config file. comp-lzo # Set log file verbosity. verb 3 # Silence repeating messages ;mute 20 But when I start server and look in /var/log/syslog, I notice the following error: May 27 22:13:51 myuser ovpn-client[5626]: /sbin/route add -net 10.27.12.1 netmask 255.255.255.252 gw 10.27.12.37 May 27 22:13:51 myuser ovpn-client[5626]: ERROR: Linux route add command failed: external program exited with error status: 4 May 27 22:13:51 myuser ovpn-client[5626]: /sbin/route add -net 172.27.12.0 netmask 255.255.255.0 gw 10.27.12.37 May 27 22:13:51 myuser ovpn-client[5626]: /sbin/route add -net 10.27.12.1 netmask 255.255.255.255 gw 10.27.12.37 And I am unable to connect to the server via openvpn: $ ssh [email protected] ssh: connect to host xxx.xx.xx.130 port 22: No route to host What may I be doing wrong?

    Read the article

  • How do I turn on wireless adapter on HP Envy dv6 7200 under Ubuntu (any version)?

    - by Dave B.
    I have a new HP Envy dv6 7200 with dual boot Windows 8 / Ubuntu 12.04. In windows, the F12 key in Windows activates the "airplane mode" switch which enables/disables both on-board (mini PCIe) and USB wireless adapters. In Ubuntu, however, the wireless adapter is turned off by default and cannot be turned back on via the F12 key (or any other combination of F12 and Ctrl, Fn, Shift, etc.). Let me explain the "fixes" I've seen in various forums and explain what did or did not happen. These are listed in no particular order. (Spoiler alert: wireless is still broke). Solution 1? Use HP's "Wireless Assistant" utility to permanently activate the wireless card in Windows, then boot into Ubuntu to happily find it working. Unfortunately, this utility works in Windows 7 but not Windows 8. On the other hand, hardware drivers from HP are only available for Windows 8 for this model. Catch 22 (I could not find a comparable utility for Windows 8). Solution 2? Use a USB wireless adapter to sidestep the on-board device. I purchased such a device from thinkpenguin.com to be sure that it would be Linux-friendly. However, the wireless switch enables / disables all wireless devices including USB. So, there's my $50 donation to the nice folks at thinkpenguin.com, but still no solution. Solution 3? Following the Think Penguin folk's suggestion, modify the mini PCI express adapter following instructions here: http://www.notebookforums.com/t/225429/broken-wireless-hardware-switch-fix Tempting, but I then violate the terms of my warranty mere days after opening the box. This might be a good solution for an older machine that you want to get your geek on with, but not for a new box. Solution 4? rfkill unblock all No effect whatsoever. ubuntu@ubuntu-hp-evny:~$ rfkill unblock all ubuntu@ubuntu-hp-evny:~$ rfkill list all 0: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: yes Solution 5? Re-install drivers. Done and done. Ubuntu recognizes the device - perhaps even without re-installing the drivers? - but cannot turn it on. How do I know this? In the Network Manager drop-down menu, the wireless option is blacked out and a message reads something like: "wireless network is disabled by a hardware switch". Solution 6? Identify a physical switch on the laptop and flip it. There is no such switch on this machine. In fact, walking through Best Buy yesterday, I checked and not a single new laptop PC had a physical switch on it. All of the wireless switches are either the F2 or F12 key ... I wonder if askubuntu will not be plagued by this exact issue in the near future? Additional info - lspci ubuntu@ubuntu-hp-evny:~$ lspci 00:00.0 Host bridge: Intel Corporation Ivy Bridge DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Ivy Bridge PCI Express Root Port (rev 09) 00:02.0 VGA compatible controller: Intel Corporation Ivy Bridge Graphics Controller (rev 09) 00:14.0 USB controller: Intel Corporation Panther Point USB xHCI Host Controller (rev 04) 00:16.0 Communication controller: Intel Corporation Panther Point MEI Controller #1 (rev 04) 00:1a.0 USB controller: Intel Corporation Panther Point USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation Panther Point High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 1 (rev c4) 00:1c.2 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 3 (rev c4) 00:1c.3 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 4 (rev c4) 00:1c.5 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 6 (rev c4) 00:1d.0 USB controller: Intel Corporation Panther Point USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation Panther Point LPC Controller (rev 04) 00:1f.2 RAID bus controller: Intel Corporation 82801 Mobile SATA Controller [RAID mode] (rev 04) 00:1f.3 SMBus: Intel Corporation Panther Point SMBus Controller (rev 04) 01:00.0 VGA compatible controller: NVIDIA Corporation Device 0de9 (rev a1) 08:00.0 Unassigned class [ff00]: Realtek Semiconductor Co., Ltd. Device 5229 (rev 01) 0a:00.0 Network controller: Ralink corp. Device 539b 0b:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 07) Any suggestions would be much appreciated!

    Read the article

  • WebLogic JDBC Use of Oracle Wallet for SSL

    - by Steve Felts
    Introduction Secure Sockets Layer (SSL) can be used to secure the connection between the middle tier “client”, WebLogic Server (WLS) in this case, and the Oracle database server.  Data between WLS and database can be encrypted.  The server can be authenticated so you have proof that the database can be trusted by validating a certificate from the server.  The client can be authenticated so that the database only accepts connections from clients that it trusts. Similar to the discussion in an earlier article about using the Oracle wallet for database credentials, the Oracle wallet can also be used with SSL to store the keys and certificates.  By using it correctly, clear text passwords can be eliminated from the JDBC configuration and client/server configuration can be simplified by sharing the wallet across multiple datasources. There is a very good Oracle Technical White Paper on using SSL with the Oracle thin driver at http://www.oracle.com/technetwork/database/enterprise-edition/wp-oracle-jdbc-thin-ssl-130128.pdf [LINK1].  The link http://www.oracle.com/technetwork/middleware/weblogic/index-087556.html [LINK2] describes how to use WebLogic Server with Oracle JDBC Driver SSL. The information in this article is a guide on what steps need to be taken in the variety of available options; use the links above for details. SSL from the driver to the database server is basically turned on by specifying a protocol of “tcps” in the URL.  However, there is a fair amount of setup needed.  Also remember that there is an overhead in performance. Creating the wallets The common use cases are 1. “data encryption and server-only authentication”, requiring just a trust store, or 2. “data encryption and authentication of both tiers” (client and server), requiring a trust store and a key store. It is recommended to use the auto-login wallet type so that clear text passwords are not needed in the datasource configuration to open the wallet.  The store type for an auto-login wallet is “SSO” (Single Sign On), not “JKS” or “PKCS12” as in [LINK2].  The file name is “cwallet.sso”. Wallets are created using the orapki tool.  They need to be created based on the usage (encryption and/or authentication).  This is discussed in detail in [LINK1] in Appendix B or in the Advanced Security Administrator’s Guide of the Database documentation. Database Server Configuration It is necessary to update the sqlnet.ora and listener.ora files with the directory location of the wallet using WALLET_LOCATION.  These files also indicate whether or not SSL_CLIENT_AUTHENTICATION is being used (true or false). The Oracle Listener must also be configured to use the TCPS protocol.  The recommended port is 2484. LISTENER = (ADDRESS_LIST= (ADDRESS=(PROTOCOL=tcps)(HOST=servername)(PORT=2484))) WebLogic Server Classpath The WebLogic Server CLASSPATH must have three additional security files. The files that need to be added to the WLS CLASSPATH are $MW_HOME/modules/com.oracle.osdt_cert_1.0.0.0.jar $MW_HOME/modules/com.oracle.osdt_core_1.0.0.0.jar $MW_HOME/modules/com.oracle.oraclepki_1.0.0.0.jar One way to do this is to add them to PRE_CLASSPATH environment variable for use with the standard WebLogic scripts. Setting the Oracle Security Provider It’s necessary to enable the Oracle PKI provider on the client side.  This can either be done statically by updating the java.security file under the JRE or dynamically by setting it in a WLS startup class using java.security.Security.insertProviderAt(new oracle.security.pki.OraclePKIProvider (), 3); See the full example of the startup class in [LINK2]. Datasource Configuration When creating a WLS datasource, set the PROTOCOL in the URL to tcps as in the following. jdbc:oracle:thin:@(DESCRIPTION=(ADDRESS=(PROTOCOL=tcps)(HOST=host)(PORT=port))(CONNECT_DATA=(SERVICE_NAME=myservice))) For encryption and server authentication, use the datasource connection properties: - javax.net.ssl.trustStore=location of wallet file on the client - javax.net.ssl.trustStoreType=”SSO” For client authentication, use the datasource connection properties: - javax.net.ssl.keyStore=location of wallet file on the client - javax.net.ssl.keyStoreType=”SSO” Note that the driver connection properties for the wallet require a file name, not a directory name. Active GridLink ONS over SSL For completeness, there is another SSL usage for WLS datasources.  The communication with the Oracle Notification Service (ONS) for load balancing information and node up/down events can use SSL also. Create an auto-login wallet and use the wallet on the client and server.  The following is a sample sequence to create a test wallet for use with ONS. orapki wallet create -wallet ons -auto_login -pwd ONS_Wallet orapki wallet add -wallet ons -dn "CN=ons_test,C=US" -keysize 1024 -self_signed -validity 9999 -pwd ONS_Wallet orapki wallet export -wallet ons -dn "CN=ons_test,C=US" -cert ons/cert.txt -pwd ONS_Wallet On the database server side, it’s necessary to define the walletfile directory in the file $CRS_HOME/opmn/conf/ons.config and run onsctl stop/start. When configuring an Active GridLink datasource, the connection to the ONS must be defined.  In addition to the host and port, the wallet file directory must be specified.  By not giving a password, a SSO wallet is assumed. Summary To use SSL with the Oracle thin driver without any clear text passwords, use an SSO Oracle Wallet.  SSL support in the Oracle thin driver is available starting in 10g Release 2.

    Read the article

  • Coping with infrastructure upgrades

    - by Fatherjack
    A common topic for questions on SQL Server forums is how to plan and implement upgrades to SQL Server. Moving from old to new hardware or moving from one version of SQL Server to another. There are other circumstances where upgrades of other systems affect SQL Server DBAs. For example, where I work at the moment there is an Microsoft Exchange (email) server upgrade in progress. It it being handled by a different team so I’m not wholly sure on the details but we are in a situation where there are currently 2 Exchange email servers – the old one and the new one. Users mail boxes are being transferred in a planned process but as we approach the old server being turned off we have to also make sure that our SQL Servers get updated to use the new SMTP server for all of the SQL Agent notifications, SSIS packages etc. My servers have a number of profiles so that various jobs can send emails on behalf of various departments and different systems. This means there are lots of places that the old server name needs to be replaced by the new one. Anyone who has set up DBMail and enjoyed the click-tastic odyssey of screens to create Profiles and Accounts and so on and so forth ought to seek some professional help in my opinion. It’s a nightmare of back and forth settings changes and it stinks. I wasn’t looking forward to heading into this mess of a UI and changing the old Exchange server name for the new one on all my SQL Instances for all of the accounts I have set up. So I did what any Englishmen with a shed would do, I decided to take it apart and see if I can fix it another way. I took a guess that we are going to be working in MSDB and Books OnLine was remarkably helpful and amongst a lot of information told me about a couple of procedures that can be used to interrogate DBMail settings. USE [msdb] -- It's where all the good stuff is kept GO EXEC dbo.sysmail_help_profile_sp; EXEC dbo.sysmail_help_account_sp; Both of these procedures take optional parameters with the same name – ID and Name. If you provide an ID or a name then the results you get back are for that specific Profile or Account. Otherwise you get details of all Profiles and Accounts on the server you are connected to. As you can see (click for a bigger image), the Account has the SMTP server information in the servername column. We want to change that value to NewSMTP.Contoso.com. Now it appears that the procedure we are looking at gets it’s data from the sysmail_account and sysmail_server tables, you can get the results the stored procedure provides if you run the code below. SELECT [account_id] , [name] , [description] , [email_address] , [display_name] , [replyto_address] , [last_mod_datetime] , [last_mod_user] FROM dbo.sysmail_account AS sa; SELECT [account_id] , [servertype] , [servername] , [port] , [username] , [credential_id] , [use_default_credentials] , [enable_ssl] , [flags] , [last_mod_datetime] , [last_mod_user] , [timeout] FROM dbo.sysmail_server AS sms Now, we have no real idea how these tables are linked and whether making an update direct to one or other of them is going to do what we want or whether it will entirely cripple our ability to send email from SQL Server so we wont touch those tables with any UPDATE TSQL. So, back to Books OnLine then and we find sysmail_update_account_sp. It’s exactly what we need. The examples in BOL take the form (as below) of having every parameter explicitly defined. Not wanting to totally obliterate the existing values by not passing values in all of the parameters I set to writing some code to gather the existing data from the tables and re-write the SMTP server name and then execute the resulting TSQL. IF OBJECT_ID('tempdb..#sysmailprofiles') IS NOT NULL DROP TABLE #sysmailprofiles GO CREATE TABLE #sysmailprofiles ( account_id INT , [name] VARCHAR(50) , [description] VARCHAR(500) , email_address VARCHAR(500) , display_name VARCHAR(500) , replyto_address VARCHAR(500) , servertype VARCHAR(10) , servername VARCHAR(100) , port INT , username VARCHAR(100) , use_default_credentials VARCHAR(1) , ENABLE_ssl VARCHAR(1) ) INSERT [#sysmailprofiles] ( [account_id] , [name] , [description] , [email_address] , [display_name] , [replyto_address] , [servertype] , [servername] , [port] , [username] , [use_default_credentials] , [ENABLE_ssl] ) EXEC [dbo].[sysmail_help_account_sp] DECLARE @TSQL NVARCHAR(1000) SELECT TOP 1 @TSQL = 'EXEC [dbo].[sysmail_update_account_sp] @account_id = ' + CAST([s].[account_id] AS VARCHAR(20)) + ', @account_name = ''' + [s].[name] + '''' + ', @email_address = N''' + [s].[email_address] + '''' + ', @display_name = N''' + [s].[display_name] + '''' + ', @replyto_address = N''' + s.replyto_address + '''' + ', @description = N''' + [s].[description] + '''' + ', @mailserver_name = ''NEWSMTP.contoso.com''' + +', @mailserver_type = ' + [s].[servertype] + ', @port = ' + CAST([s].[port] AS VARCHAR(20)) + ', @username = ' + COALESCE([s].[username], '''''') + ', @use_default_credentials =' + CAST(s.[use_default_credentials] AS VARCHAR(1)) + ', @enable_ssl =' + [s].[ENABLE_ssl] FROM [#sysmailprofiles] AS s WHERE [s].[servername] = 'SMTP.Contoso.com' SELECT @tsql EXEC [sys].[sp_executesql] @tsql This worked well for me and testing the email function EXEC dbo.sp_send_dbmail afterwards showed that the settings were indeed using our new Exchange server. It was only later in writing this blog that I tried running the sysmail_update_account_sp procedure with only the SMTP server name parameter value specified. Despite what Books OnLine might intimate, you can do this and only the values for parameters specified get changed. If a parameter is not specified in the execution of the procedure then the values remain unchanged. This renders most of the above script unnecessary as I could have simply specified the account_id that I want to amend and the new value for the parameter I want to update. EXEC sysmail_update_account_sp @account_id = 1, @mailserver_name = 'NEWSMTP.Contoso.com' This wasn’t going to be the main reason for this post, it was meant to describe how to capture values from a stored procedure and use them in dynamic TSQL but instead we are here and (re)learning the fact that Books Online is a little flawed in places. It is a fantastic resource for anyone working with SQL Server but the reader must adopt an enquiring frame of mind and use a little curiosity to try simple variations on examples to fully understand the code you are working with. I think the author(s) of this part of Books OnLine missed an opportunity to include a third example that had fewer than all parameters specified to give a lead to this method existing.

    Read the article

  • Cookbook: SES and UCM setup

    - by George Maggessy
    The purpose of this post is to guide you setting up the integration between UCM and SES. On my next post I’ll show different approaches to integrate WebCenter Portal, UCM and SES based on some common scenarios. Let’s get started. WebCenter Content Configuration WebCenter Content has a component that adds functionality to the content server to allow it to be searched via the Oracle SES. To enable the component installation, go to Administration -&gt; Admin Server and select SESCrawlerExport. Click the update button and restart UCM_server1 managed server. Once the managed server is back, we’ll configure the component. In the menu, under Administration you should see SESCrawlerExport. Click on the link. You’ll see the window below. Click on Configure SESCrawlerExport. Configure the values below: Hostname: SES hostname. Feed Location: Directory where data feeds will be saved. Metadata List: List of metadata that will be searchable by SES. After updating the values click on the Update button. Come back to the SESCrawlerExport Administration UI and click on Take Snapshot button. It will create the data feeds in the specified Feed Location. To check if the correct configuration was done, please access the following URL http://&lt;ucm_server&gt;:&lt;port&gt;/cs/idcplg?IdcService=SES_CRAWLER_DOWLOAD_CONFIG&amp;source=default. It should download config file in the format below: &lt;?xml version="1.0" encoding="UTF-8"?&gt; &lt;rsscrawler xmlns="http://xmlns.oracle.com/search/rsscrawlerconfig"&gt; &lt;feedLocation&gt;&lt;![CDATA[http://adc6160699.us.oracle.com:16200/cs/idcplg?IdcService=SES_CRAWLER_DOWNLOAD_CONTROL&amp;source=default]]&gt;&lt;/feedLocation&gt; &lt;errorFileLocation&gt;&lt;![CDATA[http://adc6160699.us.oracle.com:16200/cs/idcplg?IdcService=SES_CRAWLER_STATUS&amp;IsJava=1&amp;source=default&amp;StatusFeed=]]&gt;&lt;/errorFileLocation&gt; &lt;feedType&gt;controlFeed&lt;/feedType&gt; &lt;sourceName&gt;default&lt;/sourceName&gt; &lt;securityType&gt;attributeBased&lt;/securityType&gt; &lt;securityAttribute name="Account" grant="true"/&gt; &lt;securityAttribute name="DocSecurityGroup" grant="true"/&gt; &lt;securityAttribute name="Collab" grant="true"/&gt; &lt;/rsscrawler&gt; Make sure Account and DocSecurityGroup values are true. SES Configuration Let’s start by configuring the Identity Plug-ins in SES. Go to Global Settings -&gt; System -&gt; Identity Management Setup. Select Oracle Content Server and click the Activate button. We’ll populate the following values: HTTP endpoint for authentication: URL to WebCenter Content. Notice that /cs/idcplg was added at the end of the URL. Admin User: UCM Admin user. This user must have access to all CPOE content. Password: Password to Admin user. Authentication Type: NATIVE. Go back to the Home tab and click on Sources on the top left. Select Oracle Content Server on the right and click the Create button. Configuration URL: URL that point to the configuration file. Example: http://&lt;ucm_hostname&gt;:&lt;port&gt;/cs/idcplg?IdcService=SES_CRAWLER_DOWNLOAD_CONFIG&amp;source=default. User ID: UCM Admin user. Password: Password to Admin user. Click on the Authorization tab and add the appropriate values to the fields below. Make sure you see the ACCOUNT and DOCSECURITYGROUP security attributes at the end of the page. HTTP endpoint for authorization: http://&lt;ucm_hostname&gt;:&lt;port&gt;/cs/idcplg. Display URL prefix: http://&lt;ucm_hostname&gt;:&lt;port&gt;/cs. Administrator user: UCM Admin user. Administrator password. On the Document Types tab, add the documents that should be indexed by SES. As our last step, we’ll configure the Federation Trusted Entities under Global Settings. Entity Name: The user must be present in both the identity management server configured for your WebCenter application and the identity management server configured for Oracle SES. For instance, I used weblogic in my sample. Password: Entity user password.\ Now you are ready to test the integration on the SES UI: http://&lt;ses hostname&gt;:&lt;port&gt;/search/query/.

    Read the article

  • Data not synchornizing java sockets

    - by Droid_Interceptor
    I am writing a auction server and client and using a class called BidHandler to deal with the bids another class AuctionItem to deal with the items for auction. The main problem I am having is little synchroization problem. Screen output of client server as can see from the image at 1st it takes the new bid and changes the value of the time to it, but when one the user enters 1.0 the item seems to be changed to that. But later on when the bid changes again to 15.0 it seems to stay at that price. Is there any reason for that. I have included my code below. Sorry if didnt explain this well. This is the auction client import java.io.*; import java.net.*; public class AuctionClient { private AuctionGui gui; private Socket socket; private DataInputStream dataIn; private DataOutputStream dataOut; //Auction Client constructor String name used as identifier for each client to allow server to pick the winning bidder public AuctionClient(String name,String server, int port) { gui = new AuctionGui("Bidomatic 5000"); gui.input.addKeyListener (new EnterListener(this,gui)); gui.addWindowListener(new ExitListener(this)); try { socket = new Socket(server, port); dataIn = new DataInputStream(socket.getInputStream()); dataOut = new DataOutputStream(socket.getOutputStream()); dataOut.writeUTF(name); while (true) { gui.output.append("\n"+dataIn.readUTF()); } } catch (Exception e) { e.printStackTrace(); } } public void sentBid(String bid) { try { dataOut.writeUTF(bid); } catch(IOException e) { e.printStackTrace(); } } public void disconnect() { try { socket.close(); } catch(IOException e) { e.printStackTrace(); } } public static void main (String args[]) throws IOException { if(args.length!=3) { throw new RuntimeException ("Syntax: java AuctionClient <name> <serverhost> <port>"); } int port = Integer.parseInt(args[2]); AuctionClient a = new AuctionClient(args[0],args[1],port); } } The Auction Server import java.io.*; import java.net.*; import java.util.*; public class AuctionServer { public AuctionServer(int port) throws IOException { ServerSocket server = new ServerSocket(port); while(true) { Socket client = server.accept(); DataInputStream in = new DataInputStream(client.getInputStream()); String name = in.readUTF(); System.out.println("New client "+name+" from " +client.getInetAddress()); BidHandler b = new BidHandler (name, client); b.start(); } } public static void main(String args[]) throws IOException { if(args.length != 1) throw new RuntimeException("Syntax: java AuctionServer <port>"); new AuctionServer(Integer.parseInt(args[0])); } } The BidHandler import java.net.*; import java.io.*; import java.util.*; import java.lang.Float; public class BidHandler extends Thread { Socket socket; DataInputStream in; DataOutputStream out; String name; float currentBid = 0.0f; AuctionItem paper = new AuctionItem(" News Paper ", " Free newspaper from 1990 ", 1.0f, false); protected static Vector handlers = new Vector(); public BidHandler(String name, Socket socket) throws IOException { this.name = name; this.socket = socket; in = new DataInputStream (new BufferedInputStream (socket.getInputStream())); out = new DataOutputStream(new BufferedOutputStream(socket.getOutputStream())); } public synchronized void run() { try { broadcast("New bidder has entered the room"); handlers.addElement(this); while(true) { broadcast(paper.getName() + paper.getDescription()+" for sale at: " +paper.getPrice()); while(paper.getStatus() == false) { String message = in.readUTF(); currentBid = Float.parseFloat(message); broadcast("Bidder entered " +currentBid); if(currentBid > paper.getPrice()) { paper.setPrice(currentBid); broadcast("New Higgest Bid is "+paper.getPrice()); } else if(currentBid < paper.getPrice()) { broadcast("Higgest Bid is "+paper.getPrice()); } else if(currentBid == paper.getPrice()) { broadcast("Higgest Bid is "+paper.getPrice()); } } } } catch(IOException ex) { System.out.println("-- Connection to user lost."); } finally { handlers.removeElement(this); broadcast(name+" left"); try { socket.close(); } catch(IOException ex) { System.out.println("-- Socket to user already closed ?"); } } } protected static void broadcast (String message) { synchronized(handlers) { Enumeration e = handlers.elements(); while(e.hasMoreElements()) { BidHandler handler = (BidHandler) e.nextElement(); try { handler.out.writeUTF(message); handler.out.flush(); } catch(IOException ex) { handler = null; } } } } } The AuctionItem Class class AuctionItem { String itemName; String itemDescription; float itemPrice; boolean itemStatus; //Create a new auction item with name, description, price and status public AuctionItem(String name, String description, float price, boolean status) { itemName = name; itemDescription = description; itemPrice = price; itemStatus = status; } //return the price of the item. public synchronized float getPrice() { return itemPrice; } //Set the price of the item. public synchronized void setPrice(float newPrice) { itemPrice = newPrice; } //Get the status of the item public synchronized boolean getStatus() { return itemStatus; } //Set the status of the item public synchronized void setStatus(boolean newStatus) { itemStatus = newStatus; } //Get the name of the item public String getName() { return itemName; } //Get the description of the item public String getDescription() { return itemDescription; } } There is also simple GUI to go with this that seems to be working fine. If anyone wants it will include the GUI code.

    Read the article

  • openvpn: after changing to server mode, client does not create TUN device

    - by lurscher
    i had a previously working configuration with the config files used in a previous question However, i've changed this now to the following configuration using server mode, everything on the logs seem fine, however the client doesn't create any tun interface, so i don't have anything to connect to, presumably, i need to add or push some route commands, but i don't have any idea at this point what i need to do. I am posting all my relevant configuration files server.conf: dev tun server 10.8.117.0 255.255.255.0 ifconfig-pool-persist ipp.txt tls-server dh /home/lurscher/keys/dh1024.pem ca /home/lurscher/keys/ca.crt cert /home/lurscher/keys/vpnCh8TestServer.crt key /home/lurscher/keys/vpnCh8TestServer.key status openvpn-status.log log openvpn.log comp-lzo verb 3 and client.conf: dev tun remote my.server.com tls-client ca /home/chuckq/keys/ca.crt cert /home/chuckq/keys/vpnCh8TestClient.crt key /home/chuckq/keys/vpnCh8TestClient.key ns-cert-type server ; port 1194 ; user nobody ; group nogroup status openvpn-status.log log openvpn.log comp-lzo verb 3 the server ifconfig shows a tun device: tun0 Link encap:UNSPEC HWaddr 00-00-00-00-00-00-00-00-00-00-00-00-00-00-00-00 inet addr:10.8.117.1 P-t-P:10.8.117.2 Mask:255.255.255.255 UP POINTOPOINT RUNNING NOARP MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) However the client ifconfig does not show any tun interface! $ ifconfig tun0 tun0 Link encap:UNSPEC HWaddr 00-00-00-00-00-00-00-00-00-00-00-00-00-00-00-00 POINTOPOINT NOARP MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) the client log says: Tue May 17 23:27:09 2011 OpenVPN 2.1.0 i686-pc-linux-gnu [SSL] [LZO2] [EPOLL] [PKCS11] [MH] [PF_INET6] [eurephia] built on Jul 12 2010 Tue May 17 23:27:09 2011 IMPORTANT: OpenVPN's default port number is now 1194, based on an official port number assignment by IANA. OpenVPN 2.0-beta16 and earlier used 5000 as the default port. Tue May 17 23:27:09 2011 NOTE: the current --script-security setting may allow this configuration to call user-defined scripts Tue May 17 23:27:09 2011 /usr/bin/openssl-vulnkey -q -b 1024 -m <modulus omitted> Tue May 17 23:27:09 2011 LZO compression initialized Tue May 17 23:27:09 2011 Control Channel MTU parms [ L:1542 D:138 EF:38 EB:0 ET:0 EL:0 ] Tue May 17 23:27:09 2011 TUN/TAP device tun0 opened Tue May 17 23:27:09 2011 TUN/TAP TX queue length set to 100 Tue May 17 23:27:09 2011 Data Channel MTU parms [ L:1542 D:1450 EF:42 EB:135 ET:0 EL:0 AF:3/1 ] Tue May 17 23:27:09 2011 Local Options hash (VER=V4): '41690919' Tue May 17 23:27:09 2011 Expected Remote Options hash (VER=V4): '530fdded' Tue May 17 23:27:09 2011 Socket Buffers: R=[114688->131072] S=[114688->131072] Tue May 17 23:27:09 2011 UDPv4 link local (bound): [undef] Tue May 17 23:27:09 2011 UDPv4 link remote: [AF_INET]192.168.0.101:1194 Tue May 17 23:27:09 2011 TLS: Initial packet from [AF_INET]192.168.0.101:1194, sid=8e8bdc33 f4275407 Tue May 17 23:27:09 2011 VERIFY OK: depth=1, /C=CA/ST=Out/L=There/O=Ubuntu/OU=Home/CN=Ubuntu_CA/name=lurscher/[email protected] Tue May 17 23:27:09 2011 VERIFY OK: nsCertType=SERVER Tue May 17 23:27:09 2011 VERIFY OK: depth=0, /C=CA/ST=Out/L=There/O=Ubuntu/OU=Home/CN=vpnCh8TestServer/name=lurscher/[email protected] Tue May 17 23:27:09 2011 Data Channel Encrypt: Cipher 'BF-CBC' initialized with 128 bit key Tue May 17 23:27:09 2011 Data Channel Encrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Tue May 17 23:27:09 2011 Data Channel Decrypt: Cipher 'BF-CBC' initialized with 128 bit key Tue May 17 23:27:09 2011 Data Channel Decrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Tue May 17 23:27:09 2011 Control Channel: TLSv1, cipher TLSv1/SSLv3 DHE-RSA-AES256-SHA, 1024 bit RSA Tue May 17 23:27:09 2011 [vpnCh8TestServer] Peer Connection Initiated with [AF_INET]192.168.0.101:1194 Tue May 17 23:27:10 2011 Initialization Sequence Completed the client status log: OpenVPN STATISTICS Updated,Tue May 17 23:30:09 2011 TUN/TAP read bytes,0 TUN/TAP write bytes,0 TCP/UDP read bytes,5604 TCP/UDP write bytes,4244 Auth read bytes,0 pre-compress bytes,0 post-compress bytes,0 pre-decompress bytes,0 post-decompress bytes,0 END and the server log says: Tue May 17 23:18:25 2011 OpenVPN 2.1.0 x86_64-pc-linux-gnu [SSL] [LZO2] [EPOLL] [PKCS11] [MH] [PF_INET6] [eurephia] built on Jul 12 2010 Tue May 17 23:18:25 2011 IMPORTANT: OpenVPN's default port number is now 1194, based on an official port number assignment by IANA. OpenVPN 2.0-beta16 and earlier used 5000 as the default port. Tue May 17 23:18:25 2011 WARNING: --keepalive option is missing from server config Tue May 17 23:18:25 2011 NOTE: your local LAN uses the extremely common subnet address 192.168.0.x or 192.168.1.x. Be aware that this might create routing conflicts if you connect to the VPN server from public locations such as internet cafes that use the same subnet. Tue May 17 23:18:25 2011 NOTE: the current --script-security setting may allow this configuration to call user-defined scripts Tue May 17 23:18:25 2011 Diffie-Hellman initialized with 1024 bit key Tue May 17 23:18:25 2011 /usr/bin/openssl-vulnkey -q -b 1024 -m <modulus omitted> Tue May 17 23:18:25 2011 TLS-Auth MTU parms [ L:1542 D:138 EF:38 EB:0 ET:0 EL:0 ] Tue May 17 23:18:25 2011 ROUTE default_gateway=192.168.0.1 Tue May 17 23:18:25 2011 TUN/TAP device tun0 opened Tue May 17 23:18:25 2011 TUN/TAP TX queue length set to 100 Tue May 17 23:18:25 2011 /sbin/ifconfig tun0 10.8.117.1 pointopoint 10.8.117.2 mtu 1500 Tue May 17 23:18:25 2011 /sbin/route add -net 10.8.117.0 netmask 255.255.255.0 gw 10.8.117.2 Tue May 17 23:18:25 2011 Data Channel MTU parms [ L:1542 D:1450 EF:42 EB:135 ET:0 EL:0 AF:3/1 ] Tue May 17 23:18:25 2011 Socket Buffers: R=[126976->131072] S=[126976->131072] Tue May 17 23:18:25 2011 UDPv4 link local (bound): [undef] Tue May 17 23:18:25 2011 UDPv4 link remote: [undef] Tue May 17 23:18:25 2011 MULTI: multi_init called, r=256 v=256 Tue May 17 23:18:25 2011 IFCONFIG POOL: base=10.8.117.4 size=62 Tue May 17 23:18:25 2011 IFCONFIG POOL LIST Tue May 17 23:18:25 2011 vpnCh8TestClient,10.8.117.4 Tue May 17 23:18:25 2011 Initialization Sequence Completed Tue May 17 23:27:22 2011 MULTI: multi_create_instance called Tue May 17 23:27:22 2011 192.168.0.104:1194 Re-using SSL/TLS context Tue May 17 23:27:22 2011 192.168.0.104:1194 LZO compression initialized Tue May 17 23:27:22 2011 192.168.0.104:1194 Control Channel MTU parms [ L:1542 D:138 EF:38 EB:0 ET:0 EL:0 ] Tue May 17 23:27:22 2011 192.168.0.104:1194 Data Channel MTU parms [ L:1542 D:1450 EF:42 EB:135 ET:0 EL:0 AF:3/1 ] Tue May 17 23:27:22 2011 192.168.0.104:1194 Local Options hash (VER=V4): '530fdded' Tue May 17 23:27:22 2011 192.168.0.104:1194 Expected Remote Options hash (VER=V4): '41690919' Tue May 17 23:27:22 2011 192.168.0.104:1194 TLS: Initial packet from [AF_INET]192.168.0.104:1194, sid=8972b565 79323f68 Tue May 17 23:27:22 2011 192.168.0.104:1194 VERIFY OK: depth=1, /C=CA/ST=Out/L=There/O=Ubuntu/OU=Home/CN=Ubuntu_CA/name=lurscher/[email protected] Tue May 17 23:27:22 2011 192.168.0.104:1194 VERIFY OK: depth=0, /C=CA/ST=Out/L=There/O=Ubuntu/OU=Home/CN=Ubuntu_CA/name=lurscher/[email protected] Tue May 17 23:27:22 2011 192.168.0.104:1194 Data Channel Encrypt: Cipher 'BF-CBC' initialized with 128 bit key Tue May 17 23:27:22 2011 192.168.0.104:1194 Data Channel Encrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Tue May 17 23:27:22 2011 192.168.0.104:1194 Data Channel Decrypt: Cipher 'BF-CBC' initialized with 128 bit key Tue May 17 23:27:22 2011 192.168.0.104:1194 Data Channel Decrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Tue May 17 23:27:22 2011 192.168.0.104:1194 Control Channel: TLSv1, cipher TLSv1/SSLv3 DHE-RSA-AES256-SHA, 1024 bit RSA Tue May 17 23:27:22 2011 192.168.0.104:1194 [vpnCh8TestClient] Peer Connection Initiated with [AF_INET]192.168.0.104:1194 Tue May 17 23:27:22 2011 vpnCh8TestClient/192.168.0.104:1194 MULTI: Learn: 10.8.117.6 -> vpnCh8TestClient/192.168.0.104:1194 Tue May 17 23:27:22 2011 vpnCh8TestClient/192.168.0.104:1194 MULTI: primary virtual IP for vpnCh8TestClient/192.168.0.104:1194: 10.8.117.6 finally, the server status log: OpenVPN CLIENT LIST Updated,Tue May 17 23:36:25 2011 Common Name,Real Address,Bytes Received,Bytes Sent,Connected Since vpnCh8TestClient,192.168.0.104:1194,4244,5604,Tue May 17 23:27:22 2011 ROUTING TABLE Virtual Address,Common Name,Real Address,Last Ref 10.8.117.6,vpnCh8TestClient,192.168.0.104:1194,Tue May 17 23:27:22 2011 GLOBAL STATS Max bcast/mcast queue length,0 END

    Read the article

  • HP to Cisco spanning tree root flapping

    - by Tim Brigham
    Per a recent question I recently configured both my HP (2x 2900) and Cisco (1x 3750) hardware to use MSTP for interoperability. I thought this was functional until I applied the change to the third device (HP switch 1 below) at which time the spanning tree root started flapping causing performance issues (5% packet loss) between my two HP switches. I'm not sure why. HP Switch 1 A4 connected to Cisco 1/0/1. HP Switch 2 B2 connected to Cisco 2/0/1. HP Switch 1 A2 connected to HP Switch 2 A1. I'd prefer the Cisco stack to act as the root. EDIT: There is one specific line - 'spanning-tree 1 path-cost 500000' in the HP switch 2 that I didn't add and was preexisting. I'm not sure if it could have the kind of impact that I'm describing. I'm more a security and monitoring guy then networking. EDIT 2: I'm starting to believe the problem lies in the fact that the value for my MST 0 instance on the Cisco is still at the default 32768. I worked up a diagram: This is based on every show command I could find for STP. I'll make this change after hours and see if it helps. Cisco 3750 Config: version 12.2 spanning-tree mode mst spanning-tree extend system-id spanning-tree mst configuration name mstp revision 1 instance 1 vlan 1, 40, 70, 100, 250 spanning-tree mst 1 priority 0 vlan internal allocation policy ascending interface TenGigabitEthernet1/1/1 switchport trunk encapsulation dot1q switchport mode trunk ! interface TenGigabitEthernet2/1/1 switchport trunk encapsulation dot1q switchport mode trunk ! interface Vlan1 no ip address ! interface Vlan100 ip address 192.168.100.253 255.255.255.0 ! Cisco 3750 show spanning tree: show spanning-tree MST0 Spanning tree enabled protocol mstp Root ID Priority 32768 Address 0004.ea84.5f80 Cost 200000 Port 53 (TenGigabitEthernet1/1/1) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32768 (priority 32768 sys-id-ext 0) Address a44c.11a6.7c80 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Te1/1/1 Root FWD 2000 128.53 P2p MST1 Spanning tree enabled protocol mstp Root ID Priority 1 Address a44c.11a6.7c80 This bridge is the root Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 1 (priority 0 sys-id-ext 1) Address a44c.11a6.7c80 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Te1/1/1 Desg FWD 2000 128.53 P2p Cisco 3750 show logging: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan100, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan100, changed state to up %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up HP Switch 1: ; J9049A Configuration Editor; Created on release #T.13.71 vlan 1 name "DEFAULT_VLAN" untagged 1-8,10,13-16,18-23,A1-A4 ip address 100.100.100.17 255.255.255.0 no untagged 9,11-12,17,24 exit vlan 100 name "192.168.100" untagged 9,11-12,17,24 tagged 1-8,10,13-16,18-23,A1-A4 no ip address exit vlan 21 name "Users_2" tagged 1,A1-A4 no ip address exit vlan 40 name "Cafe" tagged 1,4,7,A1-A4 no ip address exit vlan 250 name "Firewall" tagged 1,4,7,A1-A4 no ip address exit vlan 70 name "DMZ" tagged 1,4,7-8,13,A1-A4 no ip address exit spanning-tree spanning-tree config-name "mstp" spanning-tree config-revision 1 spanning-tree instance 1 vlan 1 40 70 100 250 password manager password operator HP Switch 1 show spanning tree: show spanning-tree Multiple Spanning Tree (MST) Information STP Enabled : Yes Force Version : MSTP-operation IST Mapped VLANs : 2-39,41-69,71-99,101-249,251-4094 Switch MAC Address : 0021f7-126580 Switch Priority : 32768 Max Age : 20 Max Hops : 20 Forward Delay : 15 Topology Change Count : 363,490 Time Since Last Change : 14 hours CST Root MAC Address : 0004ea-845f80 CST Root Priority : 32768 CST Root Path Cost : 200000 CST Root Port : 1 IST Regional Root MAC Address : 0021f7-126580 IST Regional Root Priority : 32768 IST Regional Root Path Cost : 0 IST Remaining Hops : 20 Root Guard Ports : TCN Guard Ports : BPDU Protected Ports : BPDU Filtered Ports : PVST Protected Ports : PVST Filtered Ports : | Prio | Designated Hello Port Type | Cost rity State | Bridge Time PtP Edge ----- --------- + --------- ---- ---------- + ------------- ---- --- ---- A1 | Auto 128 Disabled | A2 10GbE-CX4 | 2000 128 Forwarding | 0021f7-126580 2 Yes No A3 10GbE-CX4 | Auto 128 Disabled | A4 10GbE-SR | Auto 128 Disabled | HP Switch 1 Logging: I removed the date / time fields since they are inaccurate (no NTP configured on these switches) 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to 32768:0021f7-126580 00839 stp: MSTI 1 Root changed from 32768:0021f7-126580 to 0:a44c11-a67c80 00842 stp: MSTI 1 starved for an MSTI Msg Rx on port A4 from 0:a44c11-a67c80 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to 32768:0021f7-126580 00839 stp: MSTI 1 Root changed from 32768:0021f7-126580 to 0:a44c11-a67c80 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to ... HP Switch 2 Configuration: ; J9146A Configuration Editor; Created on release #W.14.49 vlan 1 name "DEFAULT_VLAN" untagged 1,3-17,21-24,A1-A2,B2 ip address 100.100.100.36 255.255.255.0 no untagged 2,18-20,B1 exit vlan 100 name "192.168.100" untagged 2,18-20 tagged 1,3-17,21-24,A1-A2,B1-B2 no ip address exit vlan 21 name "Users_2" tagged 1,A1-A2,B2 no ip address exit vlan 40 name "Cafe" tagged 1,13-14,16,A1-A2,B2 no ip address exit vlan 250 name "Firewall" tagged 1,13-14,16,A1-A2,B2 no ip address exit vlan 70 name "DMZ" tagged 1,13-14,16,A1-A2,B2 no ip address exit logging 192.168.100.18 spanning-tree spanning-tree 1 path-cost 500000 spanning-tree config-name "mstp" spanning-tree config-revision 1 spanning-tree instance 1 vlan 1 40 70 100 250 HP Switch 2 Spanning Tree: show spanning-tree Multiple Spanning Tree (MST) Information STP Enabled : Yes Force Version : MSTP-operation IST Mapped VLANs : 2-39,41-69,71-99,101-249,251-4094 Switch MAC Address : 0024a8-cd6000 Switch Priority : 32768 Max Age : 20 Max Hops : 20 Forward Delay : 15 Topology Change Count : 21,793 Time Since Last Change : 14 hours CST Root MAC Address : 0004ea-845f80 CST Root Priority : 32768 CST Root Path Cost : 200000 CST Root Port : A1 IST Regional Root MAC Address : 0021f7-126580 IST Regional Root Priority : 32768 IST Regional Root Path Cost : 2000 IST Remaining Hops : 19 Root Guard Ports : TCN Guard Ports : BPDU Protected Ports : BPDU Filtered Ports : PVST Protected Ports : PVST Filtered Ports : | Prio | Designated Hello Port Type | Cost rity State | Bridge Time PtP Edge ----- --------- + --------- ---- ---------- + ------------- ---- --- ---- A1 10GbE-CX4 | 2000 128 Forwarding | 0021f7-126580 2 Yes No A2 10GbE-CX4 | Auto 128 Disabled | B1 SFP+SR | 2000 128 Forwarding | 0024a8-cd6000 2 Yes No B2 | Auto 128 Disabled | HP Switch 2 Logging: I removed the date / time fields since they are inaccurate (no NTP configured on these switches) 00839 stp: CST Root changed from 32768:0021f7-126580 to 32768:0004ea-845f80 00839 stp: IST Root changed from 32768:0021f7-126580 to 32768:0024a8-cd6000 00839 stp: CST Root changed from 32768:0004ea-845f80 to 32768:0024a8-cd6000 00839 stp: CST Root changed from 32768:0024a8-cd6000 to 32768:0004ea-845f80 00839 stp: CST Root changed from 32768:0004ea-845f80 to 32768:0024a8-cd6000 00435 ports: port B1 is Blocked by STP 00839 stp: CST Root changed from 32768:0024a8-cd6000 to 32768:0021f7-126580 00839 stp: IST Root changed from 32768:0024a8-cd6000 to 32768:0021f7-126580 00839 stp: CST Root changed from 32768:0021f7-126580 to 32768:0004ea-845f80

    Read the article

  • IRQ problem with 2.6.32/2.6.39 kernel on Debian Squeeze x86_64

    - by MasterM
    I recently assembled a new computer so that all hardware is pretty new. Since then I've been experiencing some problem with IRQs when running Debian 6.0. On random occasions, usually after an hour or so of running I hear a beep and this shows up in dmesg: [ 3537.762795] irq 16: nobody cared (try booting with the "irqpoll" option) [ 3537.762797] Pid: 0, comm: swapper Tainted: P W O 2.6.39-2-amd64 #1 [ 3537.762798] Call Trace: [ 3537.762799] <IRQ> [<ffffffff810924d4>] ? __report_bad_irq+0x3a/0xa2 [ 3537.762803] [<ffffffff810926a4>] ? note_interrupt+0x168/0x1da [ 3537.762805] [<ffffffff81090dd4>] ? handle_irq_event_percpu+0x171/0x18f [ 3537.762807] [<ffffffff8100e0e2>] ? read_tsc+0x5/0x16 [ 3537.762809] [<ffffffff8106b8a2>] ? update_ts_time_stats+0x32/0x6b [ 3537.762810] [<ffffffff81090e26>] ? handle_irq_event+0x34/0x52 [ 3537.762812] [<ffffffff81063fb7>] ? sched_clock_idle_wakeup_event+0x12/0x1c [ 3537.762813] [<ffffffff81092df2>] ? handle_fasteoi_irq+0x82/0xa4 [ 3537.762815] [<ffffffff8100aadb>] ? handle_irq+0x1a/0x23 [ 3537.762816] [<ffffffff8100a384>] ? do_IRQ+0x45/0xaa [ 3537.762818] [<ffffffff81332c93>] ? common_interrupt+0x13/0x13 [ 3537.762818] <EOI> [<ffffffff81332c8e>] ? common_interrupt+0xe/0x13 [ 3537.762821] [<ffffffff81026800>] ? native_safe_halt+0x2/0x3 [ 3537.762829] [<ffffffffa016ed58>] ? acpi_idle_do_entry+0x39/0x62 [processor] [ 3537.762831] [<ffffffffa016edde>] ? acpi_idle_enter_c1+0x5d/0xad [processor] [ 3537.762834] [<ffffffff81261033>] ? cpuidle_idle_call+0x11f/0x1cc [ 3537.762835] [<ffffffff81008dd2>] ? cpu_idle+0xab/0xe1 [ 3537.762837] [<ffffffff8169fc60>] ? start_kernel+0x3e0/0x3eb [ 3537.762838] [<ffffffff8169f3c8>] ? x86_64_start_kernel+0x102/0x10f [ 3537.762839] handlers: [ 3537.762840] [<ffffffffa0358d5a>] (rtl8169_interrupt+0x0/0x2d7 [r8169]) [ 3537.762842] [<ffffffffa08ff2ca>] (nv_kern_isr+0x0/0x54 [nvidia]) [ 3537.762902] Disabling IRQ #16 After that Xorg either hogs on CPU or is unstable (up to hanging the system completely). When I restart Xorg everything is fine again and the problem doesn't occur until next reboot. I tried to upgrade the kernel from stock 2.6.32 to 2.6.39 from unstable repository but that didn't help. Booting with irqpoll option only seems to prolong the initial time period after which the problem occurs. I'm using latest NVIDIA drivers and Realtek firmware from firmware-realtek package. I have two GTX 560Ti that run in SLI. Disabling SLI or taking out one card completely doesn't solve the problem either. Output of uname -a is: Linux whitestar 2.6.39-2-amd64 #1 SMP Wed Jun 8 11:01:04 UTC 2011 x86_64 GNU/Linux Output of lspci is: 00:00.0 Host bridge: Intel Corporation Sandy Bridge DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Sandy Bridge PCI Express Root Port (rev 09) 00:01.1 PCI bridge: Intel Corporation Sandy Bridge PCI Express Root Port (rev 09) 00:16.0 Communication controller: Intel Corporation Cougar Point HECI Controller #1 (rev 04) 00:19.0 Ethernet controller: Intel Corporation 82579V Gigabit Network Connection (rev 05) 00:1a.0 USB Controller: Intel Corporation Cougar Point USB Enhanced Host Controller #2 (rev 05) 00:1b.0 Audio device: Intel Corporation Cougar Point High Definition Audio Controller (rev 05) 00:1c.0 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 1 (rev b5) 00:1c.1 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 2 (rev b5) 00:1c.2 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 3 (rev b5) 00:1c.4 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 5 (rev b5) 00:1c.6 PCI bridge: Intel Corporation 82801 PCI Bridge (rev b5) 00:1d.0 USB Controller: Intel Corporation Cougar Point USB Enhanced Host Controller #1 (rev 05) 00:1f.0 ISA bridge: Intel Corporation Cougar Point LPC Controller (rev 05) 00:1f.2 SATA controller: Intel Corporation Cougar Point 6 port SATA AHCI Controller (rev 05) 00:1f.3 SMBus: Intel Corporation Cougar Point SMBus Controller (rev 05) 01:00.0 VGA compatible controller: nVidia Corporation Device 1200 (rev a1) 01:00.1 Audio device: nVidia Corporation Device 0e0c (rev a1) 02:00.0 VGA compatible controller: nVidia Corporation Device 1200 (rev a1) 02:00.1 Audio device: nVidia Corporation Device 0e0c (rev a1) 04:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 04) 06:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 04) 07:00.0 PCI bridge: Device 1b21:1080 (rev 01) 08:02.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8110SC/8169SC Gigabit Ethernet (rev 10) 08:03.0 FireWire (IEEE 1394): VIA Technologies, Inc. VT6306/7/8 [Fire II(M)] IEEE 1394 OHCI Controller (rev c0) Contents of /proc/interrupts: CPU0 CPU1 CPU2 CPU3 CPU4 CPU5 CPU6 CPU7 0: 77 0 0 0 0 0 0 0 IO-APIC-edge timer 1: 2 0 0 0 0 0 0 0 IO-APIC-edge i8042 8: 1 0 0 0 0 0 0 0 IO-APIC-edge rtc0 9: 0 0 0 0 0 0 0 0 IO-APIC-fasteoi acpi 12: 4 0 0 0 0 0 0 0 IO-APIC-edge i8042 16: 699083 0 0 0 0 0 0 0 IO-APIC-fasteoi nvidia, eth0 17: 87810 0 0 0 0 0 0 0 IO-APIC-fasteoi firewire_ohci, hda_intel, nvidia 18: 242 0 0 0 0 0 0 0 IO-APIC-fasteoi hda_intel 23: 85925 0 0 0 0 0 0 0 IO-APIC-fasteoi ehci_hcd:usb5, ehci_hcd:usb6 40: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 41: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 42: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 43: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 44: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 45: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 46: 79853 0 0 0 0 0 0 0 PCI-MSI-edge ahci 48: 1 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 49: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 50: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 51: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 52: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 53: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 54: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 55: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 56: 1 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 57: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 58: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 59: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 60: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 61: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 62: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 63: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 64: 173506 0 0 0 0 0 0 0 PCI-MSI-edge hda_intel NMI: 482 89 25 13 277 24 11 10 Non-maskable interrupts LOC: 783857 194752 114133 70577 372438 179065 117179 162016 Local timer interrupts SPU: 0 0 0 0 0 0 0 0 Spurious interrupts PMI: 482 89 25 13 277 24 11 10 Performance monitoring interrupts IWI: 0 0 0 0 0 0 0 0 IRQ work interrupts RES: 131917 46750 7432 3291 150003 9576 3435 3067 Rescheduling interrupts CAL: 2759 6563 7150 6997 5387 7140 7269 6678 Function call interrupts TLB: 4396 2038 1336 492 5434 1896 1121 606 TLB shootdowns TRM: 0 0 0 0 0 0 0 0 Thermal event interrupts THR: 0 0 0 0 0 0 0 0 Threshold APIC interrupts MCE: 0 0 0 0 0 0 0 0 Machine check exceptions MCP: 37 37 37 37 37 37 37 37 Machine check polls ERR: 0 MIS: 0 Last but not least, right after boot-up those lines are usually present in dmesg: [ 18.367094] hda-intel: IRQ timing workaround is activated for card #1. Suggest a bigger bdl_pos_adj. [ 18.458859] hda-intel: IRQ timing workaround is activated for card #2. Suggest a bigger bdl_pos_adj. I'm not sure if it's related or a symptom of a bigger problem so I'm posting it just in case. I don't really know what other information might be of relevance here. Don't hesitate to ask for more in the comments.

    Read the article

  • Our embedded linux system won't recognize a USB Device if it is plugged in before powerup. Suggestions?

    - by Blaine
    We are developing on a small embedded device. This device us a gumstix overo board running OpenEmbedded linux. We have our development almost completely done, and have run into the strangest of bugs that we can't figure out. We have a USB Device (Spectrophotometer) that has a USB2.0 Connection and an external power supply for the light source. Typical behavior is that you plug in the power supply, then the USB connection to a host. When the usb connection is detected by the device, the device boots up and enables the light source and fan. The device is then able to be used by the host system. The problem is that if the device is plugged into the Gumstix before we turn on the Gumstix, the USB Device apparently is not probed by the system (and hence does not turn on). Under a normal situation, when the connection is initialized by plugging in the usb cable, the spectro turns itself on and becomes available to the system (this can be seen via "lsusb" typically). Neither of these things are happening. There is no device detected via "lsusb" and no dmesg errors of any kind that we can see. It is as if the device is not plugged in. The device does show up and work fine if we unplug the USB cable and plug it back in once the system is booted up. It turns on and shows up on the usb bus, and we can access it with our driver. On any other desktop or laptop, it does not matter if the host system is on or off when we plug in the spectrometer. This behavior is what I would consider to be "normal" - that the usb system is probed and initialized at boot time, and the usb devices come online. In other words, our system is fully functional as long as we plug in the usb device after the system is booted up. Unfortunately this isn't possible in our final product - everything comes on at once. Additional Info: 1) We have tried a flash drive attached to the system when the system is turned off. Booting up the system brings the flash drive online, as expected 2) There are no messages regarding the spectro or usb device (using dmesg). "lsusb" only lists the USB hubs / controllers. It is literally as if the device is not present and not plugged in. 3) We have tried a brand new image from gumstix and an older image from last year. Both images have this problem. This problem exists on all 3 gumstix devices we use. Does anyone have any suggestions? From what I can tell it isn't really possible to do a complete "reboot" of the usb system that is a complete emulation of "unplugging" and "replugging" a usb device. I feel like what is happening is that there is no initial probe on the usb bus that would trigger the usb handshaking, but this is somehow specific to the spectro. This seems to be a kernel issue or at least an issue in how the kernel is initializing the usb subsystem. I'm not really sure though. I have tried the gumstix mailing list, but there doesn't seem to be anyone who has seen this issue before. Any advice or suggestions on where to start looking would be fantastic. Thank you! Blaine output etc. $ uname -a Linux overo 2.6.33 #1 Tue Apr 27 08:35:38 PDT 2010 armv7l GNU/Linux When the system is up and running and spectro is plugged in (working as intended), this is lsusb: Bus 001 Device 116: ID 2457:1022 Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x2457 idProduct 0x1022 bcdDevice 0.02 iManufacturer 1 USB4000 1.01.11 iProduct 2 Ocean Optics USB4000 iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 46 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0x80 (Bus Powered) MaxPower 400mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 4 bInterfaceClass 255 Vendor Specific Class bInterfaceSubClass 0 bInterfaceProtocol 0 iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x01 EP 1 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x82 EP 2 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x86 EP 6 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0000 (Bus Powered) dmesg output: usb usb1: usb auto-resume hub 1-0:1.0: hub_resume usb usb2: usb auto-resume ehci-omap ehci-omap.0: resume root hub hub 1-0:1.0: state 7 ports 1 chg 0000 evt 0000 hub 2-0:1.0: hub_resume hub 2-0:1.0: state 7 ports 3 chg 0000 evt 0000 hub 1-0:1.0: hub_suspend usb usb1: bus auto-suspend hub 2-0:1.0: hub_suspend usb usb2: bus auto-suspend ehci-omap ehci-omap.0: suspend root hub usb usb2: usb resume ehci-omap ehci-omap.0: resume root hub hub 2-0:1.0: hub_resume ehci-omap ehci-omap.0: GetStatus port 2 status 001803 POWER sig=j CSC CONNECT hub 2-0:1.0: port 2: status 0501 change 0001 hub 2-0:1.0: state 7 ports 3 chg 0004 evt 0000 hub 2-0:1.0: port 2, status 0501, change 0000, 480 Mb/s ehci-omap ehci-omap.0: port 2 high speed ehci-omap ehci-omap.0: GetStatus port 2 status 001005 POWER sig=se0 PE CONNECT usb 2-2: new high speed USB device using ehci-omap and address 2 ehci-omap ehci-omap.0: port 2 high speed ehci-omap ehci-omap.0: GetStatus port 2 status 001005 POWER sig=se0 PE CONNECT usb 2-2: default language 0x0409 usb 2-2: udev 2, busnum 2, minor = 129 usb 2-2: New USB device found, idVendor=2457, idProduct=1022 usb 2-2: New USB device strings: Mfr=1, Product=2, SerialNumber=0 usb 2-2: Product: Ocean Optics USB4000 usb 2-2: Manufacturer: USB4000 1.01.11 usb 2-2: uevent usb 2-2: usb_probe_device usb 2-2: configuration #1 chosen from 1 choice usb 2-2: uevent usb 2-2: adding 2-2:1.0 (config #1, interface 0) usb 2-2:1.0: uevent drivers/usb/core/inode.c: creating file '002' dmesg has nothing to say, and lusb simply lists nothing else but the two default usb controllers / hubs if we plug the device in before the system is turned on.

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • c#: sms appears to have been sent, but stuck in phone outbox

    - by I__
    i wrote code to send an SMS using my gsm phone which is attached to the computer through com port. the code is below. the problem is i do see that it is in the outbox of the phone and it actually appears to have been sent, but when i contact the recipient they say that i have not received the message. i test the phone, and i create and send a message using only the phone and it works perfectly, however when i do this with my code, it APPEARS to have been sent, and i am getting all the correct AT COMMAND responses from the phone, but the message is actually NOT sent. here is the code: using System; using System.Collections.Generic; using System.ComponentModel; using System.Data; using System.Drawing; using System.Linq; using System.Text; using System.Windows.Forms; using System.Threading; using System.IO.Ports; namespace WindowsFormsApplication1 { public partial class Form1 : Form { SerialPort serialPort1; int m_iTxtMsgState = 0; const int NUM_MESSAGE_STATES = 4; const string RESERVED_COM_1 = "COM1"; const string RESERVED_COM_4 = "COM4"; public Form1() { InitializeComponent(); this.Closing += new CancelEventHandler(Form1_Closing); } private void Form1_Load(object sender, EventArgs e) { serialPort1 = new SerialPort(GetUSBComPort()); if (serialPort1.IsOpen) { serialPort1.Close(); } serialPort1.Open(); //ThreadStart myThreadDelegate = new ThreadStart(ReceiveAndOutput); //Thread myThread = new Thread(myThreadDelegate); //myThread.Start(); this.serialPort1.DataReceived += new SerialDataReceivedEventHandler(sp_DataReceived); } private void Form1_Closing(object sender, System.ComponentModel.CancelEventArgs e) { serialPort1.Close(); } private void SendLine(string sLine) { serialPort1.Write(sLine); sLine = sLine.Replace("\u001A", ""); consoleOut.Text += sLine; } public void DoWork() { ProcessMessageState(); } public void ProcessMessageState() { switch (m_iTxtMsgState) { case 0: m_iTxtMsgState = 1; SendLine("AT\r\n"); //NOTE: SendLine must be the last thing called in all of these! break; case 1: m_iTxtMsgState = 2; SendLine("AT+CMGF=1\r\n"); break; case 2: m_iTxtMsgState = 3; SendLine("AT+CMGW=" + Convert.ToChar(34) + "+9737387467" + Convert.ToChar(34) + "\r\n"); break; case 3: m_iTxtMsgState = 4; SendLine("A simple demo of SMS text messaging." + Convert.ToChar(26)); break; case 4: m_iTxtMsgState = 5; break; case 5: m_iTxtMsgState = NUM_MESSAGE_STATES; break; } } private string GetStoredSMSID() { return null; } /* //i dont think this part does anything private void serialPort1_DataReceived_1(object sender, System.IO.Ports.SerialDataReceivedEventArgs e) { string response = serialPort1.ReadLine(); this.BeginInvoke(new MethodInvoker(() => textBox1.AppendText(response + "\r\n"))); } */ void sp_DataReceived(object sender, SerialDataReceivedEventArgs e) { try { Thread.Sleep(500); char[] msg; msg = new char[613]; int iNumToRead = serialPort1.BytesToRead; serialPort1.Read(msg, 0, iNumToRead); string response = new string(msg); this.BeginInvoke(new MethodInvoker(() => textBox1.AppendText(response + "\r\n"))); serialPort1.DiscardInBuffer(); if (m_iTxtMsgState == 4) { int pos_cmgw = response.IndexOf("+CMGW:"); string cmgw_num = response.Substring(pos_cmgw + 7, 4); SendLine("AT+CMSS=" + cmgw_num + "\r\n"); //stop listening to messages received } if (m_iTxtMsgState < NUM_MESSAGE_STATES) { ProcessMessageState(); } } catch { } } private void button1_Click(object sender, EventArgs e) { m_iTxtMsgState = 0; DoWork(); } private void button2_Click(object sender, EventArgs e) { string[] sPorts = SerialPort.GetPortNames(); foreach (string port in sPorts) { consoleOut.Text += port + "\r\n"; } } private string GetUSBComPort() { string[] sPorts = SerialPort.GetPortNames(); foreach (string port in sPorts) { if (port != RESERVED_COM_1 && port != RESERVED_COM_4) { return port; } } return null; } }

    Read the article

  • Sending mail with Gmail Account using System.Net.Mail in ASP.NET

    - by Jalpesh P. Vadgama
    Any web application is in complete without mail functionality you should have to write send mail functionality. Like if there is shopping cart application for example then when a order created on the shopping cart you need to send an email to administrator of website for Order notification and for customer you need to send an email of receipt of order. So any web application is not complete without sending email. This post is also all about sending email. In post I will explain that how we can send emails from our Gmail Account without purchasing any smtp server etc. There are some limitations for sending email from Gmail Account. Please note following things. Gmail will have fixed number of quota for sending emails per day. So you can not send more then that emails for the day. Your from email address always will be your account email address which you are using for sending email. You can not send an email to unlimited numbers of people. Gmail ant spamming policy will restrict this. Gmail provide both Popup and SMTP settings both should be active in your account where you testing. You can enable that via clicking on setting link in gmail account and go to Forwarding and POP/Imap. So if you are using mail functionality for limited emails then Gmail is Best option. But if you are sending thousand of email daily then it will not be Good Idea. Here is the code for sending mail from Gmail Account. using System.Net.Mail; namespace Experiement { public partial class WebForm1 : System.Web.UI.Page { protected void Page_Load(object sender,System.EventArgs e) { MailMessage mailMessage = new MailMessage(new MailAddress("[email protected]") ,new MailAddress("[email protected]")); mailMessage.Subject = "Sending mail through gmail account"; mailMessage.IsBodyHtml = true; mailMessage.Body = "<B>Sending mail thorugh gmail from asp.net</B>"; System.Net.NetworkCredential networkCredentials = new System.Net.NetworkCredential("[email protected]", "yourpassword"); SmtpClient smtpClient = new SmtpClient(); smtpClient.EnableSsl = true; smtpClient.UseDefaultCredentials = false; smtpClient.Credentials = networkCredentials; smtpClient.Host = "smtp.gmail.com"; smtpClient.Port = 587; smtpClient.Send(mailMessage); Response.Write("Mail Successfully sent"); } } } That’s run this application and you will get like below in your account. Technorati Tags: Gmail,System.NET.Mail,ASP.NET

    Read the article

  • Deploy ASP.NET Web Applications with Web Deployment Projects

    - by Ben Griswold
    One may quickly build and deploy an ASP.NET web application via the Publish option in Visual Studio.  This option works great for most simple deployment scenarios but it won’t always cut it.  Let’s say you need to automate your deployments. Or you have environment-specific configuration settings. Or you need to execute pre/post build operations when you do your builds.  If so, you should consider using Web Deployment Projects. The Web Deployment Project type doesn’t come out-of-the-box with Visual Studio 2008.  You’ll need to Download Visual Studio® 2008 Web Deployment Projects – RTW and install if you want to follow along with this tutorial. I’ve created a shiny new ASP.NET MVC project.  Web Deployment Projects work with websites, web applications and MVC projects so feel free to go with any web project type you’d like.  Once your web application is in place, it’s time to add the Web Deployment project.  You can hunt and peck around the File > New > New Project… dialogue as long as you’d like, but you aren’t going to find what you need.  Instead, select the web project and then choose the “Add Web Deployment Project…” hiding behind the Build menu option. I prefer to name my projects based on the environment in which I plan to deploy.  In this case, I’ll be rolling to the QA machine. Don’t expect too much to happen at this point.  A seemingly empty project with a funny icon will be added to your solution.  That’s it. I want to take a minute and talk about configuration settings before we continue.  Some of the common settings which might change from environment to environment are appSettings, connectionStrings and mailSettings.  Here’s a look at my updated web.config: <appSettings>   <add key="MvcApplication293.Url" value="http://localhost:50596/" />     </appSettings> <connectionStrings>   <add name="ApplicationServices"        connectionString="data source=.\SQLEXPRESS;Integrated Security=SSPI;AttachDBFilename=|DataDirectory|aspnetdb.mdf;User Instance=true"        providerName="System.Data.SqlClient"/> </connectionStrings>   <system.net>   <mailSettings>     <smtp from="[email protected]">         <network host="server.com" userName="username" password="password" port="587" defaultCredentials="false"/>     </smtp>   </mailSettings> </system.net> I want to update these values prior to deploying to the QA environment.  There are variations to this approach, but I like to maintain environment-specific settings for each of the web.config sections in the Config/[Environment] project folders.  I’ve provided a screenshot of the QA environment settings below. It may be obvious what one should include in each of the three files.  Basically, it is a copy of the associated web.config section with updated setting values.  For example, the AppSettings.config file may include a reference to the QA web url, the DB.config would include the QA database server and login information and the StmpSettings.config would include a QA Stmp server and user information. <?xml version="1.0" encoding="utf-8" ?> <appSettings>   <add key="MvcApplication293.Url" value="http://qa.MvcApplicatinon293.com/" /> </appSettings> AppSettings.config  <?xml version="1.0" encoding="utf-8" ?> <connectionStrings>   <add name="ApplicationServices"        connectionString="server=QAServer;integrated security=SSPI;database=MvcApplication293"        providerName="System.Data.SqlClient"/>   </connectionStrings> Db.config  <?xml version="1.0" encoding="utf-8" ?> <smtp from="[email protected]">     <network host="qaserver.com" userName="qausername" password="qapassword" port="587" defaultCredentials="false"/> </smtp> SmtpSettings.config  I think our web project is ready to deploy.  Now, it’s time to concentrate on the Web Deployment Project itself.  Right-click on the project file and open the Property Pages. The first thing to call out is the Configuration dropdown.  I only deploy a project which is built in Release Mode so I only setup the Web Deployment Project for this mode.  (This is when you change the Configuration selection to “Release.”)  I typically keep the Output Folder default value – .\Release\.  When the application is built, all artifacts will be dropped in the .\Release\ folder relative to the Web Deployment Project root.  The final option may be up for some debate.  I like to roll out updatable websites so I select the “Allow this precompiled site to be updatable” option.  I really do like to follow standard SDLC processes when I release my software but there are those times when you just have to make a hotfix to production and I like to keep this option open if need be.  If you are strongly opposed to this idea, please, by all means, don’t check the box. The next tab is boring.  I don’t like to deploy a crazy number of DLLs so I merge all outputs to a single assembly.  Again, you may have another option and feel free to change this selection if you so wish. If you follow my lead, take care when choosing a single assembly name.  The Assembly Name can not be the same as the website or any other project in your solution otherwise you’ll receive a circular reference build error.  In other words, I can’t name the assembly MvcApplication293 or my output window would start yelling at me. Remember when we called out our QA configuration files?  Click on the Deployment tab and you’ll see how where going to use them.  Notice the Web.config file section replacements value.  All this does is swap called out web.config sections with the content of the Config\QA\* files.  You can reduce or extend this list as you deem fit.  Did you see the “Use external configuration source file” option?  You know how you can point any of your web.config sections to an external file via the configSource attribute?  This option allows you to leverage that technique and instead of replacing the content of the sections, you will replace the configSource attribute value instead. <appSettings configSource="Config\QA\AppSettings.config" /> Go ahead and Apply your changes.  I’d like to take a look at the project file we just updated.  Right-click on the Web Deployment Project and select “Open Project File.” One of the first configuration blocks reflects core Release build settings.  There are a couple of points I’d like to call out here: DebugSymbols=false ensures the compilation debug attribute in your web.config is flipped to false as part of build process.  There’s some crumby (more likely old) documentation which implies you need a ToggleDebugCompilation task to make this happen.  Nope. Just make sure the DebugSymbols is set to false.  EnableUpdateable implies a single dll for the web application rather than a dll for each object and and empty view file. I think updatable applications are cleaner and include the benefit (or risk based on your perspective) that portions of the application can be updated directly on the server.  I called this out earlier but I wanted to reiterate. <PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Release|AnyCPU' ">     <DebugSymbols>false</DebugSymbols>     <OutputPath>.\Release</OutputPath>     <EnableUpdateable>true</EnableUpdateable>     <UseMerge>true</UseMerge>     <SingleAssemblyName>MvcApplication293</SingleAssemblyName>     <DeleteAppCodeCompiledFiles>true</DeleteAppCodeCompiledFiles>     <UseWebConfigReplacement>true</UseWebConfigReplacement>     <ValidateWebConfigReplacement>true</ValidateWebConfigReplacement>     <DeleteAppDataFolder>true</DeleteAppDataFolder>   </PropertyGroup> The next section is self-explanatory.  The content merely reflects the replacement value you provided via the Property Pages. <ItemGroup Condition="'$(Configuration)|$(Platform)' == 'Release|AnyCPU'">     <WebConfigReplacementFiles Include="Config\QA\AppSettings.config">       <Section>appSettings</Section>     </WebConfigReplacementFiles>     <WebConfigReplacementFiles Include="Config\QA\Db.config">       <Section>connectionStrings</Section>     </WebConfigReplacementFiles>     <WebConfigReplacementFiles Include="Config\QA\SmtpSettings.config">       <Section>system.net/mailSettings/smtp</Section>     </WebConfigReplacementFiles>   </ItemGroup> You’ll want to extend the ItemGroup section to include the files you wish to exclude from the build.  The sample ExcludeFromBuild nodes exclude all obj, svn, csproj, user, pdb artifacts from the build. Enough though they files aren’t included in your web project, you’ll need to exclude them or they’ll show up along with required deployment artifacts.  <ItemGroup Condition="'$(Configuration)|$(Platform)' == 'Release|AnyCPU'">     <WebConfigReplacementFiles Include="Config\QA\AppSettings.config">       <Section>appSettings</Section>     </WebConfigReplacementFiles>     <WebConfigReplacementFiles Include="Config\QA\Db.config">       <Section>connectionStrings</Section>     </WebConfigReplacementFiles>     <WebConfigReplacementFiles Include="Config\QA\SmtpSettings.config">       <Section>system.net/mailSettings/smtp</Section>     </WebConfigReplacementFiles>     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\obj\**\*.*" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\**\.svn\**\*.*" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\**\.svn\**\*" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\**\*.csproj" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\**\*.user" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\bin\*.pdb" />     <ExcludeFromBuild Include="$(SourceWebPhysicalPath)\Notes.txt" />   </ItemGroup> Pre/post build and Pre/post merge tasks are added to the final code block.  By default, your project file should look like the following – a completely commented out section. <!– To modify your build process, add your task inside one of        the targets below and uncomment it. Other similar extension        points exist, see Microsoft.WebDeployment.targets.   <Target Name="BeforeBuild">   </Target>   <Target Name="BeforeMerge">   </Target>   <Target Name="AfterMerge">   </Target>   <Target Name="AfterBuild">   </Target>   –> Update the section to remove all temporary Config folders and files after the build.  <!– To modify your build process, add your task inside one of        the targets below and uncomment it. Other similar extension        points exist, see Microsoft.WebDeployment.targets.     <Target Name="BeforeMerge">   </Target>   <Target Name="AfterMerge">   </Target>     <Target Name="BeforeBuild">      </Target>       –>   <Target Name="AfterBuild">     <!– WebConfigReplacement requires the Config files. Remove after build. –>     <RemoveDir Directories="$(OutputPath)\Config" />   </Target> That’s it for setup.  Save the project file, flip the solution to Release Mode and build.  If there’s an issue, consult the Output window for details.  If all went well, you will find your deployment artifacts in your Web Deployment Project folder like so. Both the code source and published application will be there. Inside the Release folder you will find your “published files” and you’ll notice the Config folder is no where to be found.  In the Source folder, all project files are found with the exception of the items which were excluded from the build. I’ll wrap up this tutorial by calling out a little Web Deployment pet peeve of mine: there doesn’t appear to be a way to add an existing web deployment project to a solution.  The best I can come up with is create a new web deployment project and then copy and paste the contents of the existing project file into the new project file.  It’s not a big deal but it bugs me. Download the Solution

    Read the article

  • Docky have stopped working since update

    - by Fraekkert
    I'm running Ubuntu 10.10 64-bit. I'm using the Docky ppa, and since the latest update It won't start. If i run it from the terminal, this is what i get: [Info 09:21:19.005] Docky version: 2.1.0 bzr docky r1761 ppa [Info 09:21:19.024] Kernel version: 2.6.35.24 [Info 09:21:19.026] CLR version: 2.0.50727.1433 [Debug 09:21:19.493] [UserArgs] BufferTime = 0 [Debug 09:21:19.494] [UserArgs] MaxSize = 2147483647 [Debug 09:21:19.494] [UserArgs] NetbookMode = False [Debug 09:21:19.494] [UserArgs] NoPollCursor = False [Debug 09:21:19.528] [SystemService] Using org.freedesktop.UPower for battery information [Info 09:21:19.564] [ThemeService] Setting theme: Transparent [Debug 09:21:19.587] [DesktopItemService] Loading remap file '/usr/share/docky/remaps.ini'. [Debug 09:21:19.599] [DesktopItemService] Remapping 'Picasa3.exe' to 'picasa'. [Debug 09:21:19.599] [DesktopItemService] Remapping 'nbexec' to 'netbeans'. [Debug 09:21:19.599] [DesktopItemService] Remapping 'deja-dup-preferences' to 'deja-dup'. [Debug 09:21:19.599] [DesktopItemService] Remapping 'VirtualBox' to 'virtualbox'. [Warn 09:21:19.600] [DesktopItemService] Could not find remap file '/home/lasse/.local/share/docky/remaps.ini'! [Debug 09:21:19.602] [DesktopItemService] Loading desktop item cache '/home/lasse/.cache/docky/docky.desktop.en_DK.utf8.cache'. [Info 09:21:20.101] [DockServices] Dock services initialized. [Debug 09:21:20.134] [DBusManager] DBus Registered: org.gnome.Docky [Debug 09:21:20.142] [DBusManager] DBus Registered: net.launchpad.DockManager Stacktrace: at (wrapper managed-to-native) System.IO.MonoIO.Read (intptr,byte[],int,int,System.IO.MonoIOError&) <IL 0x00012, 0x00062> at (wrapper managed-to-native) System.IO.MonoIO.Read (intptr,byte[],int,int,System.IO.MonoIOError&) <IL 0x00012, 0x00062> at System.IO.FileStream.ReadData (intptr,byte[],int,int) <IL 0x00009, 0x00047> at System.IO.FileStream.RefillBuffer () <IL 0x0001c, 0x0002b> at System.IO.FileStream.ReadByte () <IL 0x00079, 0x000c7> at Mono.Addins.Serialization.BinaryXmlReader.ReadNext () <IL 0x0000b, 0x00031> at Mono.Addins.Serialization.BinaryXmlReader.Skip () <IL 0x0003c, 0x00053> at Mono.Addins.Serialization.BinaryXmlReader.Skip () <IL 0x00047, 0x0005f> at Mono.Addins.Serialization.BinaryXmlReader.Skip () <IL 0x00047, 0x0005f> And this .Skip () continues infinitely, and very fast. I've tried cleaning the cache and reinstalling docky, but without luck.

    Read the article

  • Dovecot: no auth attempts in 0 secs (IMAP protocol)

    - by Luca D'Amico
    I'm having a lot of problems configuring dovecot ony vps. I'm already able to send email using port 110 and to receive email using port 25, but I can't connect using port 993 and 995. I'm using self-signed ssl certificates. When I try to connect to 993 this error is logged: Jun 8 19:06:39 MY_HOSTNAME dovecot: imap-login: Disconnected (no auth attempts in 2 secs): user=<>, rip=MY_IP, lip=MY_VPS_IP, TLS, session=<MY_SESSION> When I try to connect to 995 here is the error log: Jun 8 19:08:17 MY_HOSTNAME dovecot: pop3-login: Disconnected (no auth attempts in 0 secs): user=<>, rip=MY_IP, lip=MY_VPS_IP, TLS: SSL_read() failed: error:14094416:SSL routines:SSL3_READ_BYTES:sslv3 alert certificate unknown: SSL alert number 46, session=<MY_SESSION> EDIT: I was able to fix this part by refreshing my mail client ssl cert. Anybody can help me please ? I'm stuck :/ Many thanks

    Read the article

  • Why does ssh hang after "debug1: loaded 3 keys"

    - by James Moore
    Trying to log in to an Amazon EC2 instance running Ubuntu 10.04.1. I can log in just fine, no issues. A different user, coming from a different network just gets this: OpenSSH_4.3p2, OpenSSL 0.9.8e-fips-rhel5 01 Jul 2008 debug1: Reading configuration data /etc/ssh/ssh_config debug1: Applying options for * debug1: Connecting to xxxx [xxxx] port 80. debug1: Connection established. debug1: identity file /.ssh/identity type -1 debug1: identity file /.ssh/id_rsa type -1 debug1: identity file /.ssh/id_dsa type -1 debug1: loaded 3 keys And then it hangs. We've tried running sshd on port 22 and port 80 I'm guessing that it's not a firewall problem since the verbose output reports that the connection is established. I don't see anything in /var/log/auth.log when the failing user connects. I do see entries when I log in successfully.

    Read the article