Search Results

Search found 4620 results on 185 pages for 'serial over lan'.

Page 109/185 | < Previous Page | 105 106 107 108 109 110 111 112 113 114 115 116  | Next Page >

  • How to use iSCSI inside HyperV VM?

    - by William
    I have 2 Dell R710 servers (intended to set up HyperV cluster) and a MD3000i SAN set up: Server1/Server2: NIC 1: connected to company LAN NIC 2: crossover to the other server's NIC 2 NIC 3: crossover to iSCSI port of SAN controller 1 NIC 4: crossover to iSCSI port of SAN controller 2 I have both servers setup as diskless servers with iSCSI boot from SAN without problem. But how can I access iSCSI from within the VM such that I can set up clustering inbetween the VMs? I can ping from the host to the SAN but found that NIC3/4 cannot be used for virtual network in HyperV? What am I doing wrong?

    Read the article

  • Problem with Jumbo Frames

    - by Spookyone
    Hello, I am trying to set up jumbo frames on my gigabit home LAN but no luck so far. My setup is: * D-Link DIR-655 router, HW Revision A3, Firmware 1.21 EU * Synology DS107+, Firmware 3.0-1337 * Laptop w/ Win7 x64, external PCIx NIC managed by "Generic Marvel Yukon 88E8053 based Ethernet Controller" The router is supposed to support jumbo frames but doesn't feature any relevant setting. I set the Jumbo Packet value to 9000 on both the NIC and the Synobox but it doesn't work, ping -f -l 8972 says "Packet needs to be fragmented but DF set". Is there any other setting I overlooked, the DIR-655 doesn't actually support jumbo frames, or what else could be the problem?

    Read the article

  • Is it possible to redirect/bounce TCP traffic to external destination, base on rules?

    - by xfx
    I'm not even sure if this is possible... Also, please forgive my ignorance on the subject. What I'm looking for is for "something" that would allow me to redirect all TCP traffic arriving to host A to host B, but based on some rules. Say host A (the intermediary) receives a request (say a simple HTTP request) from a host with domain X. In that case, it lets it pass through and it's handled by host A itself. Now, let's suppose that host A receives another HTTP request from a host with domain Y, but this time, due to some customizable rules, host A redirects all the traffic to host B, and host B is able to handle it as if came directly from domain Y. And, at this point, both host B and the host with domain Y are able to freely communicate (of course, thought host A). NOTE: All these hosts are on the Internet, not inside a LAN. Please, let me know if the explanation is not clear enough.

    Read the article

  • Implications of allowing Windows clients to use NTLMv1?

    - by Boden
    I have a web application that I'd like to authenticate to using pass-through NTLM for SSO. There is a problem, however, in that NTLMv2 apparently will not work in this scenario (without the application storing an identical password hash). I enabled NTLMv1 on one client machine (Vista) using its local group policy: Computer-Windows Settings-Security Settings-Network Security: LAN Manager authentication level. I changed it to Send LM & NTLM - use NTLMv2 session security if negotiated. This worked, and I'm able to login to the web application using NTLM. Now this application would be used by all of my client machines... so I'm wondering what the security risks are if I was push this policy out to all of them (not to the domain controller itself though)?

    Read the article

  • How low-power can a home server get?

    - by Halik
    I've got quite simple question actually. How green, low-power and efficient x86 home server can I build using consumer parts with rather constrained budget. After looking through some Google hits I've found out that system based on dual-core atom, some modest mITX board (gigabit lan, integrated audio and gfx etc), one RAM module and one 'green' WD HDD, powered by picoITX PSU uses about 30W at idle up to 40 at load. Can you get lower (or how much lower) then that? Maybe some VIA nano chips, or single core atom? My home server would take care of some back-upping mixed with little ftp/http traffic.

    Read the article

  • Windows Server - Dual NIC Bandwidth Pooling

    - by tsilb
    I have a Windows Server 2008 machine with dual NICs. Both are plugged into the same switch in a typical one-switch, one-gateway home network. This server is used almost exclusively for inbound connections. It hosts a web server (IIS 6), SQL server, and file server (via LAN UNC paths and mapped drives). How do I make best use of inbound bandwidth across both NICs? For example, if I connect to it by hostname and one of the interfaces has high traffic, I'd like the new connection to use the other interface.

    Read the article

  • Not able to connect to perforce server outside of localhost

    - by bobber205
    My setup is a Qwest PK5000 router with a Linksys router running Tomato. I have DMZ pointed towards my router. (The server is on the tomato router). I tried my applications that open up sockets and Utorrent (port 6883) and I ended having to do advanced port forwarding and forward specific ports in addition to having DMZ on my router. The problem is that I cannot connect to perforce when on another machine on the LAN or off. Any ideas? :) Thanks!

    Read the article

  • iptables: matching multiple ip addresses

    - by Tax
    Hi guys, I am working on a iptables rule to apply after my shorewall script has initialized my firewall. I want a spicific IP (10.0.1.19) address in my lan to be redirected to 10.0.64.1 except if it is going to paypal. I have the following rule, and that works like a charm iptables -t nat -A PREROUTING ! -d 1.2.3.4 -s 10.0.1.19 -j DNAT --to 10.0.64.1 My problem is that paypal uses multiple ip addresses, and I am not allowed to have multiple IP-addresses. https://ppmts.custhelp.com/cgi-bin/ppdts.cfg/php/enduser/std%5Fadp.php?p%5Ffaqid=92 On top of this problem I would like to know how to remove the rule again, without having to restart shorewall. Kind regards Tax

    Read the article

  • Edimax wireless router is not providing DNS services correctly

    - by Nathan Fellman
    I have an Edimax router that is set up to connect to the internet via L2TP on cable, and on the LAN side it's set up as a DHCP server. The DHCP server gives correct IP addresses, but it sets itself up as the DNS server. However, it doesn't provide the DNS service. I am sure that it's a problem with the router, because I have two computers on the network with the same problem. I see that on the WAN side it gets correct DNS addresses from the ISP, so I'd expect the router to either pass these addresses through to the DHCP clients, or to serve the DNS requests itself by forwarding them to the ISP's DNS. However, it apparently does neither, and there is no DNS. I switched from ADSL to cable last week. On ADSL it connected using PPPoE, and the DNS worked fine. What can be the problem here?

    Read the article

  • internet connection drops randomly

    - by Remus Rigo
    hi all I have 3 PC's at home (with Win XP, Win 7 & Win 7) and a router. I am always connected to the internet through the router (PPoE connection). My problem is that sometimes when I want to search or open a page, my browser tells me that the server cannot be reached, as if I don't have a connection to the internet. Other times it logs me out from messenger, but browsing still works. FTP download/upload also works. If i disable and enable the LAN then all works fine. The connection doesn't always drop on all three PC's at the same time. Anyone got any idea besides re-installing OS? thanks

    Read the article

  • How to enable Hardware-assisted decoding in Ubuntu 9.10, specifically for Totem and/or Gnome MPlayer

    - by techtechmo
    Hi all, just wanted to ask about Hardware-assisted 720p video playback on an Intel Atom D510 machine, running on Ubuntu 9.10 Karmic Koala. When I use Boxee with Hardware Assisted Decoding activated, I am able to play 720p videos -- whether on the local harddisk drive or on a remote server, through LAN. However when I play the same 720p videos through Totem or through Gnome MPlayer, the resulting playback suffers from stuttering and slideshow-like slowdowns. Would it be possible to make 720p video playback on Totem and Gnome MPlayer more smooth given that my machine's processor in the Intel Atom D510? If yes, how? Boxee seems to manage, so I assume it should also be possible to tweak Totem and/or Gnome MPlayer to be able to do the same. As an added note, I the machine's OS is Linux Mint 8. Installed RAM is 2GB.

    Read the article

  • How do you confirm network adapter is gigabit capable?

    - by StrandedPirate
    Upgrading my network to gigabit speeds and don't know how to determine if the NIC in one of the systems is capable of gigabit speed. The documentation from the manufacturer states this: Network adapter 10/100/1000 Ethernet LAN on system board However when I go to the properties of the NIC under Speed & Duplex my only options are: 10 Mb Full 10 Mb Half 100 Mb Full 100 Mb Half Auto Is there a command line I can run that will give me more detail about the NIC? Windows 7 x64 OS New Info: The new switch I just bought has a light to indicate 1000Mbps. I can tell from the light that this NIC is indeed negotiating at 1000Mbps but I'd still like to know how to determine this from the console in windows.

    Read the article

  • Connect work laptop (domain) to home workgroup

    - by jjeaton
    Is there an easy way to have my work laptop connect to a home workgroup for file sharing with my other PCs, but then easily switch back to connecting to my work domain when I'm at work? I have the following setup: Windows 7 Home Premium Server/HTPC 2 Windows XP laptops 1 Vista laptop (Work) The work laptop connects to a work domain, the remaining computers are on a home workgroup for sharing files/printer. Also is it possible to share files over my LAN while I'm connected to the work domain, but at home? I've tried Live Mesh, but my 2 home laptops are very slow and don't work well with it. I also use Dropbox, but I'd like to be able to share larger files. I may be missing a simple solution here...

    Read the article

  • How to get started with tcp/ip v6?

    - by Johan
    Hi Now and then there is "news" about that the ip numbers will run out in X years, and we must change to tcp/ip v6... And even thou this crisis never really happens it has waken a question, how do you get started with tcp/ip v6? What can I do at home and is this a good or bad idea? Can you use IPv4 and IPv6 in the same cables in the same LAN, or do you need to physically separate them? Can you have some translation box so you can reach the "normal" internet from the IPv6 connected devices? (Just like a NAT-Router) Can someone please clarify the situation a little bit? Thanks Johan

    Read the article

  • Driver choice for addressing ubuntu wireless card issues

    - by Holly
    Hello, this should be a relatively simple question. I'm attempting to get my windows wireless card to work with ubuntu, booted from my portable hard drive. This is the guide I'm attempting to follow is on help.ubuntu.com, /community/WifiDocs/Driver/Ndiswrapper My wireless card is a Broadcom Corporation BCM4318 AirForce One 54g 802.11g Wireless LAN Controller. My computer is an HP Pavilion Entertainment dv5 notebook, which came with Vista 64. I would like confirmation about which of the drivers I should use. At this point, I'm leaning towards Broadcom BCM4318 HP Pavilion zv6000, but I thought it best to ask advice before taking action. The drivers I have to chose from are listed on this page http://sourceforge.net/apps/mediawiki/ndiswrapper/index.php?title=Category:Broadcom Thanks! Holly

    Read the article

  • mini linux for browsing media playing

    - by Martin Beckett
    I'm looking for a small linux install (<100Mb) that can just run a browser and ideally a media player. It's to fit in a spare recovery partition on my laptop and be a quick boot for non-work stuff when I'm on the road. I have used Puppy-linux and DSL before but they have lots of stuff I don't need. Is there something like these that just concentrates on running a browser in the way xbmc does for videos? ps. The size requirement was to fit in the existing 100Mb win7 recovery partition, but that can be resized. The main idea was something that booted very quickly without the 10min wait while windows does all the corporate stuff and realizes it isn't on the LAN - and could be shutdown instantly.

    Read the article

  • SNMP counter issues with cisco RV082

    - by Chance
    Does anyone else poll this router with SNMP? We are using firmware version: 2.0.0.19-tz We are having problems with the traffic counters, some of them appear to be implemented as 16 bit counter instead of 32 bit counters. The reason this is causing problems is that they roll over (at 65,000) to 0 in less than our minute polling cycle, really skewing our metrics. The counter for the Lan (interface 2) seems to be functioning properly, however interfaces 3 and 4 (WAN and DMZ / WAN2) rollover at 65000. Tue May 11 08:38:31 EDT 2010 IF-MIB::ifInOctets.1 = Counter32: 137634 IF-MIB::ifInOctets.2 = Counter32: 1865677943 IF-MIB::ifInOctets.3 = Counter32: 12450 IF-MIB::ifInOctets.4 = Counter32: 49354 Look at counter IF-MIB::ifInOctets.4 5 seconds later: Tue May 11 08:38:36 EDT 2010 IF-MIB::ifInOctets.1 = Counter32: 137634 IF-MIB::ifInOctets.2 = Counter32: 1865836207 IF-MIB::ifInOctets.3 = Counter32: 13167 IF-MIB::ifInOctets.4 = Counter32: 12900 Any suggestions? Seems like a bug to me, however I just wanted to make sure I wasn't crazy.. Thanks!

    Read the article

  • internet connection problem related to a recurring registry error

    - by mats
    I have a Windows XP desktop system connected to the Internet via ethernet LAN. Initially, none of my browsers were connecting to the Internet, but I was able to update my antivirus software and all of my connection settings were perfect. I was able to solve the problem by running WinSock XP, which apparently fixes connection problems that have been caused by registry issues. My problem now is that every time I shut down the machine, the problem comes back (Internet browsers won't connect). Does anyone have any ideas/suggestions on this? Thanks

    Read the article

  • Strange Recurrent Excessive I/O Wait

    - by Chris
    I know quite well that I/O wait has been discussed multiple times on this site, but all the other topics seem to cover constant I/O latency, while the I/O problem we need to solve on our server occurs at irregular (short) intervals, but is ever-present with massive spikes of up to 20k ms a-wait and service times of 2 seconds. The disk affected is /dev/sdb (Seagate Barracuda, for details see below). A typical iostat -x output would at times look like this, which is an extreme sample but by no means rare: iostat (Oct 6, 2013) tps rd_sec/s wr_sec/s avgrq-sz avgqu-sz await svctm %util 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 16.00 0.00 156.00 9.75 21.89 288.12 36.00 57.60 5.50 0.00 44.00 8.00 48.79 2194.18 181.82 100.00 2.00 0.00 16.00 8.00 46.49 3397.00 500.00 100.00 4.50 0.00 40.00 8.89 43.73 5581.78 222.22 100.00 14.50 0.00 148.00 10.21 13.76 5909.24 68.97 100.00 1.50 0.00 12.00 8.00 8.57 7150.67 666.67 100.00 0.50 0.00 4.00 8.00 6.31 10168.00 2000.00 100.00 2.00 0.00 16.00 8.00 5.27 11001.00 500.00 100.00 0.50 0.00 4.00 8.00 2.96 17080.00 2000.00 100.00 34.00 0.00 1324.00 9.88 1.32 137.84 4.45 59.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 22.00 44.00 204.00 11.27 0.01 0.27 0.27 0.60 Let me provide you with some more information regarding the hardware. It's a Dell 1950 III box with Debian as OS where uname -a reports the following: Linux xx 2.6.32-5-amd64 #1 SMP Fri Feb 15 15:39:52 UTC 2013 x86_64 GNU/Linux The machine is a dedicated server that hosts an online game without any databases or I/O heavy applications running. The core application consumes about 0.8 of the 8 GBytes RAM, and the average CPU load is relatively low. The game itself, however, reacts rather sensitive towards I/O latency and thus our players experience massive ingame lag, which we would like to address as soon as possible. iostat: avg-cpu: %user %nice %system %iowait %steal %idle 1.77 0.01 1.05 1.59 0.00 95.58 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sdb 13.16 25.42 135.12 504701011 2682640656 sda 1.52 0.74 20.63 14644533 409684488 Uptime is: 19:26:26 up 229 days, 17:26, 4 users, load average: 0.36, 0.37, 0.32 Harddisk controller: 01:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 1078 (rev 04) Harddisks: Array 1, RAID-1, 2x Seagate Cheetah 15K.5 73 GB SAS Array 2, RAID-1, 2x Seagate ST3500620SS Barracuda ES.2 500GB 16MB 7200RPM SAS Partition information from df: Filesystem 1K-blocks Used Available Use% Mounted on /dev/sdb1 480191156 30715200 425083668 7% /home /dev/sda2 7692908 437436 6864692 6% / /dev/sda5 15377820 1398916 13197748 10% /usr /dev/sda6 39159724 19158340 18012140 52% /var Some more data samples generated with iostat -dx sdb 1 (Oct 11, 2013) Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sdb 0.00 15.00 0.00 70.00 0.00 656.00 9.37 4.50 1.83 4.80 33.60 sdb 0.00 0.00 0.00 2.00 0.00 16.00 8.00 12.00 836.00 500.00 100.00 sdb 0.00 0.00 0.00 3.00 0.00 32.00 10.67 9.96 1990.67 333.33 100.00 sdb 0.00 0.00 0.00 4.00 0.00 40.00 10.00 6.96 3075.00 250.00 100.00 sdb 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4.00 0.00 0.00 100.00 sdb 0.00 0.00 0.00 2.00 0.00 16.00 8.00 2.62 4648.00 500.00 100.00 sdb 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.00 0.00 0.00 100.00 sdb 0.00 0.00 0.00 1.00 0.00 16.00 16.00 1.69 7024.00 1000.00 100.00 sdb 0.00 74.00 0.00 124.00 0.00 1584.00 12.77 1.09 67.94 6.94 86.00 Characteristic charts generated with rrdtool can be found here: iostat plot 1, 24 min interval: http://imageshack.us/photo/my-images/600/yqm3.png/ iostat plot 2, 120 min interval: http://imageshack.us/photo/my-images/407/griw.png/ As we have a rather large cache of 5.5 GBytes, we thought it might be a good idea to test if the I/O wait spikes would perhaps be caused by cache miss events. Therefore, we did a sync and then this to flush the cache and buffers: echo 3 > /proc/sys/vm/drop_caches and directly afterwards the I/O wait and service times virtually went through the roof, and everything on the machine felt like slow motion. During the next few hours the latency recovered and everything was as before - small to medium lags in short, unpredictable intervals. Now my question is: does anybody have any idea what might cause this annoying behaviour? Is it the first indication of the disk array or the raid controller dying, or something that can be easily mended by rebooting? (At the moment we're very reluctant to do this, however, because we're afraid that the disks might not come back up again.) Any help is greatly appreciated. Thanks in advance, Chris. Edited to add: we do see one or two processes go to 'D' state in top, one of which seems to be kjournald rather frequently. If I'm not mistaken, however, this does not indicate the processes causing the latency, but rather those affected by it - correct me if I'm wrong. Does the information about uninterruptibly sleeping processes help us in any way to address the problem? @Andy Shinn requested smartctl data, here it is: smartctl -a -d megaraid,2 /dev/sdb yields: smartctl 5.40 2010-07-12 r3124 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Device: SEAGATE ST3500620SS Version: MS05 Serial number: Device type: disk Transport protocol: SAS Local Time is: Mon Oct 14 20:37:13 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: 20 C Drive Trip Temperature: 68 C Elements in grown defect list: 0 Vendor (Seagate) cache information Blocks sent to initiator = 1236631092 Blocks received from initiator = 1097862364 Blocks read from cache and sent to initiator = 1383620256 Number of read and write commands whose size <= segment size = 531295338 Number of read and write commands whose size > segment size = 51986460 Vendor (Seagate/Hitachi) factory information number of hours powered up = 36556.93 number of minutes until next internal SMART test = 32 Error counter log: Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 509271032 47 0 509271079 509271079 20981.423 0 write: 0 0 0 0 0 5022.039 0 verify: 1870931090 196 0 1870931286 1870931286 100558.708 0 Non-medium error count: 0 SMART Self-test log Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours) # 1 Background short Completed 16 36538 - [- - -] # 2 Background short Completed 16 36514 - [- - -] # 3 Background short Completed 16 36490 - [- - -] # 4 Background short Completed 16 36466 - [- - -] # 5 Background short Completed 16 36442 - [- - -] # 6 Background long Completed 16 36420 - [- - -] # 7 Background short Completed 16 36394 - [- - -] # 8 Background short Completed 16 36370 - [- - -] # 9 Background long Completed 16 36364 - [- - -] #10 Background short Completed 16 36361 - [- - -] #11 Background long Completed 16 2 - [- - -] #12 Background short Completed 16 0 - [- - -] Long (extended) Self Test duration: 6798 seconds [113.3 minutes] smartctl -a -d megaraid,3 /dev/sdb yields: smartctl 5.40 2010-07-12 r3124 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Device: SEAGATE ST3500620SS Version: MS05 Serial number: Device type: disk Transport protocol: SAS Local Time is: Mon Oct 14 20:37:26 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: 19 C Drive Trip Temperature: 68 C Elements in grown defect list: 0 Vendor (Seagate) cache information Blocks sent to initiator = 288745640 Blocks received from initiator = 1097848399 Blocks read from cache and sent to initiator = 1304149705 Number of read and write commands whose size <= segment size = 527414694 Number of read and write commands whose size > segment size = 51986460 Vendor (Seagate/Hitachi) factory information number of hours powered up = 36596.83 number of minutes until next internal SMART test = 28 Error counter log: Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 610862490 44 0 610862534 610862534 20470.133 0 write: 0 0 0 0 0 5022.480 0 verify: 2861227413 203 0 2861227616 2861227616 100872.443 0 Non-medium error count: 1 SMART Self-test log Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours) # 1 Background short Completed 16 36580 - [- - -] # 2 Background short Completed 16 36556 - [- - -] # 3 Background short Completed 16 36532 - [- - -] # 4 Background short Completed 16 36508 - [- - -] # 5 Background short Completed 16 36484 - [- - -] # 6 Background long Completed 16 36462 - [- - -] # 7 Background short Completed 16 36436 - [- - -] # 8 Background short Completed 16 36412 - [- - -] # 9 Background long Completed 16 36404 - [- - -] #10 Background short Completed 16 36401 - [- - -] #11 Background long Completed 16 2 - [- - -] #12 Background short Completed 16 0 - [- - -] Long (extended) Self Test duration: 6798 seconds [113.3 minutes]

    Read the article

  • website not accessible with IIS6 while NAT is configured in Windows 2003

    - by Mohammed Rizwan
    I have Windows2003 server configured with IIS 6. Until now it was working fine, but since I enabled NAT for my users to access the internet via this server, the website becomes unavailable. Note that I have two nics on the server one is WAN and 2nd is for LAN. Both IPs are behind the firewall. If I stop the NAT then the website is available externally. I tried to search the answer in this forum but didn't find appropriate one or maybe didn't properly understand. I'll appreciate if anyone can help me sorting out this issue.

    Read the article

  • TightVNC grey screen?

    - by gary
    I'm trying to help my mom remotely with some PC problems. She's not too computer savvy, so to keep the firewall stuff on my side of things, I tried to use a reverse VNC connection: On my machine, I set up TightVNC client in listening mode. I also opened TCP port 5500 on my router and firewall, and checked it using http://canyouseeme.org/. On her machine, I (instructed her to) set up TightVNC server, and connect to my machine's IP ('Add New Client...'). Both machines run Windows XP & TightVNC 1.3.10. The problem: When she tries to connect, a TightVNC window with grey background pops up on my machine, but I never get to see the remote desktop. It just remains grey. However, it seems that I control the mouse on the remote side (she says it's moving). I tried to reverse-connect from another machine on my LAN and it works without a problem. Any idea what the problem could be?

    Read the article

  • CentOS 6.5 as WebServer for Django Dev

    - by Charlesliam
    During CentOS 6.5 Installation I choose WebServer type for this computer. The server has a static IP address 192.168.111.100. The CentOS was updated I managed to install virtualenv with Python 2.7. Within the virtualenv, I'll be using Django Framework. After I tried to run the command using root user python manage.py runserver 0.0.0.0:8000 I can't see the website from other computer within the LAN when I try to type 192.168.111.100:8000/admin on my browser. I already disable firewall using service iptables stop I can ping the 192.168.111.100 and I have a good feedback with nslookup. What seems the problem of my config?

    Read the article

  • Linux Router - Share bandwidth per IPs with current active connections

    - by SRoe
    We have a Linux machine running as a custom router, currently utilising Shorewall. This sits between our incoming internet connection and the internal LAN. What we would like to achieve is 'fair use' of the bandwidth on a per IP basis. If only one person currently has an active connection then they get 100% utilisation of the line. However if 20 people have active connections then they should each get 5% utilisation of the line. This should be irrespective of the number of connections held by each user. For example, say we have two users, Bill and Ted, that both have active connections. Bill has a single active connection while Ted has ten active connections. Bill should get 50% utilisation for his single connections whilst Ted should get 5% utilisation for each of his ten connections, giving Ted a total utilisation of 50%.

    Read the article

  • How do ring and bus network connect to router?

    - by lantopology
    Sorry this is probably a very silly question, but for some reason i am confused. How does a LAN with bus or ring topology connect to a router and other LANs? For example in a star network they all connect to a switch which can then connect to a router, but where does a switch go and fit in a bus or ring topology? In this image of a ring network there is no switch: http://www.brainbell.com/tutorials/Networking/images/01fig04.gif would the switch in the ring network simply be placed alongside the other nodes? Thank you very much

    Read the article

  • Windows Server 2008 R2 DNS Server Intermittently Unresponsive

    - by Ablue
    Throughout the day out DNS servers (2x Win 2k8 R2 servers) are unable to respond to requests. The requests that fail are all on the .root zone that are either cached or obtained from 1 of 5 DNS servers we forward to before going to root hints. At first I thought the DNS servers we were forwarding to were flaky. So I added some more in. Currently the forwarding list looks like ISP DNS 1 OPEN DNS 1 ISP DNS 2 OPEN DNS 2 ISP DNS 3 I have tried: Turning off root hints. Set record scavenging to 7 days. Using dnscmd /config /EnableEDNSProbes 0 as per this. Packet capture at the DNS server shows that there is a lot of query responses with server failure between lan clients and the local dns server; it does not appear to be forwarding those requests. So maybe a problem with caching? Anyhow, does anything have anything I can try to get this working?

    Read the article

< Previous Page | 105 106 107 108 109 110 111 112 113 114 115 116  | Next Page >