  • USB Flash not recognised by Windows and BIOS, but works fine in Linux

    - by bbalegere
    I have a Transcend JetFLash 2GB USB Drive.It was working fine and I had been using it occasionally. All of sudden it stopped working in all versions of Windows . The USB Drive is also not recognised by the BIOS.It does not show in the list of bootable devices.(It used show up in the list earlier) However the USB Drive works fine in my Linux Mint 11 OS. Running dmesg gives this [ 941.812192] usb 1-2: new high speed USB device using ehci_hcd and address 4 [ 941.936178] usb 1-2: device descriptor read/64, error -71 [ 942.164188] usb 1-2: device descriptor read/64, error -71 [ 942.380189] usb 1-2: new high speed USB device using ehci_hcd and address 5 [ 942.504138] usb 1-2: device descriptor read/64, error -71 [ 942.732179] usb 1-2: device descriptor read/64, error -71 [ 942.948154] usb 1-2: new high speed USB device using ehci_hcd and address 6 [ 943.364134] usb 1-2: device not accepting address 6, error -71 [ 943.476172] usb 1-2: new high speed USB device using ehci_hcd and address 7 [ 943.892140] usb 1-2: device not accepting address 7, error -71 [ 943.892191] hub 1-0:1.0: unable to enumerate USB device on port 2 [ 944.296190] usb 2-2: new full speed USB device using uhci_hcd and address 3 [ 944.438251] usb 2-2: not running at top speed; connect to a high speed hub [ 944.709928] usbcore: registered new interface driver uas [ 944.729999] Initializing USB Mass Storage driver... [ 944.730509] scsi6 : usb-storage 2-2:1.0 [ 944.730908] usbcore: registered new interface driver usb-storage [ 944.730917] USB Mass Storage support registered. [ 945.736320] scsi 6:0:0:0: Direct-Access JetFlash Transcend 2GB 8.07 PQ: 0 ANSI: 2 [ 945.744547] sd 6:0:0:0: Attached scsi generic sg1 type 0 [ 945.753316] sd 6:0:0:0: [sdb] 3944448 512-byte logical blocks: (2.01 GB/1.88 GiB) [ 945.758274] sd 6:0:0:0: [sdb] Write Protect is off [ 945.758288] sd 6:0:0:0: [sdb] Mode Sense: 03 00 00 00 [ 945.765167] sd 6:0:0:0: [sdb] No Caching mode page present [ 945.765181] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 945.784309] sd 6:0:0:0: [sdb] No Caching mode page present [ 945.784323] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 946.239512] sdb: sdb1 [ 946.257279] sd 6:0:0:0: [sdb] No Caching mode page present [ 946.257292] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 946.257302] sd 6:0:0:0: [sdb] Attached SCSI removable disk Looks like there is something wrong the USB Drive.It is not recognised in any computer running Windows. Is there any way to fix this? Any idea why this problem occurred ?

    Read the article

  • usb_modeswitch not switching

    - by deniz
    After I upgraded from kernel 2.6.18 to 3.5.3 modeswitch started not to work for me. Although lsusb shows my usb modem, usb_modeswitch does not switch it. My system information is like below. I ran lsusb, dmesg, usb-devices and usb_modeswitch their output is like below. usb_modeswitch instead of switching my modem it says "No devices in default mode found. Nothing to do. Bye.". Can you offer a solution? Kernel: Linux 3.5.3 usb_modeswitch: 1.2.3-1 usb_modeswitch-data: 20120120-1 usbutils: 006-1 libusb: 1.0.8-0.1 root@localhost$ lsusb Bus 002 Device 029: ID 12d1:1446 Huawei Technologies Co., Ltd. root@localhost$ dmesg [70112.477080] usb 2-1.4: new high-speed USB device number 30 using ehci_hcd [70112.567757] scsi49 : usb-storage 2-1.4:1.0 [70112.567842] scsi50 : usb-storage 2-1.4:1.1 [70113.571433] scsi 49:0:0:0: CD-ROM HUAWEI Mass Storage 2.31 PQ: 0 ANSI: 2 [70113.572304] scsi 50:0:0:0: Direct-Access HUAWEI TF CARD Storage PQ: 0 ANSI: 2 [70113.574169] sr0: scsi-1 drive [70113.574223] sr 49:0:0:0: Attached scsi CD-ROM sr0 [70113.574250] sr 49:0:0:0: Attached scsi generic sg1 type 5 [70113.574350] sd 50:0:0:0: Attached scsi generic sg2 type 0 [70113.577173] sd 50:0:0:0: [sdb] Attached SCSI removable disk root@localhost$ usb-devices T: Bus=02 Lev=02 Prnt=02 Port=03 Cnt=01 Dev#= 30 Spd=480 MxCh= 0 D: Ver= 2.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=12d1 ProdID=1446 Rev=00.00 S: Manufacturer=Huawei Technologies S: Product=HUAWEI Mobile C: #Ifs= 2 Cfg#= 1 Atr=c0 MxPwr=500mA I: If#= 0 Alt= 0 #EPs= 2 Cls=08(stor.) Sub=06 Prot=50 Driver=usb-storage I: If#= 1 Alt= 0 #EPs= 2 Cls=08(stor.) Sub=06 Prot=50 Driver=usb-storage root@localhost$ cat /etc/usb_modeswitch.d/12d1\:1446 # Huawei, newer modems TargetVendor= 0x12d1 TargetProductList="1001,1406,140b,140c,1412,141b,1433,1436,14ac,1506" MessageContent="55534243123456780000000000000011062000000100000000000000000000" root@localhost$ usb_modeswitch -c /etc/usb_modeswitch.d/12d1:1446 -v 12d1 -p 1446 -W * usb_modeswitch: handle USB devices with multiple modes * Version 1.2.3 (C) Josua Dietze 2012 * Based on libusb0 (0.1.12 and above) ! PLEASE REPORT NEW CONFIGURATIONS ! DefaultVendor= 0x12d1 DefaultProduct= 0x1446 TargetVendor= 0x12d1 TargetProduct= not set TargetClass= not set TargetProductList="1001,1406,140b,140c,1412,141b,1433,1436,14ac,1506" DetachStorageOnly=0 HuaweiMode=0 SierraMode=0 SonyMode=0 QisdaMode=0 GCTMode=0 KobilMode=0 SequansMode=0 MobileActionMode=0 CiscoMode=0 MessageEndpoint= not set MessageContent="55534243123456780000000000000011062000000100000000000000000000" NeedResponse=0 ResponseEndpoint= not set InquireDevice enabled (default) Success check disabled System integration mode disabled usb_set_debug: Setting debugging level to 15 (on) usb_os_find_busses: Skipping non bus directory devices usb_os_find_busses: Skipping non bus directory drivers usb_os_find_busses: Skipping non bus directory uevent usb_os_find_busses: Skipping non bus directory drivers_probe usb_os_find_busses: Skipping non bus directory drivers_autoprobe Looking for target devices ... No devices in target mode or class found Looking for default devices ... No devices in default mode found. Nothing to do. Bye. Thanks in advance.

    Read the article

  • Win Server 2008 Hanging on "Applying Computer Settings"

    - by revoked
    Applied ~8 updates this morning, and on reboot the server just sits on "Applying Computer Settings". I've let it sit for a max of almost 40m with no response. I hard-booted (/duck) and can get into safe-mode. From there it applies it's updates and is ok. But still on normal boot gets stuck in "applying". I've tried uninstalling the updates from safe-mode with the same reaction. Any insights?

    Read the article

  • LACP : Cisco ASA 5515 & Switch ProCurve 2920

    - by user979276
    I've two ASAs 5515 connected in failover Active/Stand by (on Gi0/5) My two ASAs are connected to two Switch ProCurve 2920 to have HA if something happens. So I plug something like that (don't pay attention to the arrows) : So one the ASA, I created a Port-Channel like that : interface GigabitEthernet0/0 nameif outside security-level 0 ip address 192.168.1.3 255.255.255.0 standby 192.168.1.4 ! interface GigabitEthernet0/1 speed 1000 duplex full channel-group 1 mode passive no nameif no security-level no ip address ! interface GigabitEthernet0/2 speed 1000 duplex full channel-group 1 mode passive no nameif no security-level no ip address ! interface Port-channel1.1 vlan 1 nameif inside security-level 100 ip address 192.168.8.1 255.255.255.0 standby 192.168.8.2 ! interface Port-channel1.10 vlan 10 nameif guest security-level 50 ip address 172.16.100.2 255.255.255.224 standby 172.16.100.3 ! interface Port-channel1.16 vlan 16 nameif dmz security-level 50 ip address 192.168.16.1 255.255.255.0 standby 192.168.16.2 On the switch, I created a trunk LACP capable with the port 1 and 2 on each switch, force the speed to 1000 and put the port un full duplex mode. BUT this is not working... I tried many things and I can't make it work. In this configuration, I can't ping anything between my ASA and my Switch (or any object connected). Here what I get on my ASA : Channel group 1 LACP port Admin Oper Port Port Port Flags State Priority Key Key Number State ----------------------------------------------------------------------------- Gi0/2 SP not-bndl 32768 0x1 0x1 0x3 0xc Gi0/1 FP not-bndl 32768 0x1 0x1 0x2 0x6 And on the Switchs : PORT LACP TRUNK PORT LACP LACP NUMB ENABLED GROUP STATUS PARTNER STATUS ----- ------- ----- ------ ------- ------ 1 Active trk1 Broken Yes Failure 2 Active trk1 Broken Yes Failure If I change the Cisco interface to LACP mode On, I can ping the switch from the ASA but nothing other objects conneted on the switch. If I look at the statut of LACP on the switch I see this : PORT LACP TRUNK PORT LACP LACP NUMB ENABLED GROUP STATUS PARTNER STATUS ----- ------- ----- ------ ------- ------ 1 Active trk1 Up No Success 2 Active trk1 Up No Success I don't have any clue on what's going on so If someone have any idea and help me on this, it would be great ! Feel free to ask me anything if you need any more information ! Thanks a lot !

    Read the article

  • Adaptec 5805 not recognized after reboot

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not recognized. It only works if the computer is shut down and turned off. I have recently updated the firmware to "Adaptec RAID 5805 Firmware Build 18948". How do I fix the problem? Configuration summary --------------------------- 1. Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priority High Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1

    Read the article

  • What would cause intermittent DomainKey-Status: failures?

    - by wherestheph
    Every week, we send something like a small newsletter. Sometimes, the header in the newsletter says DomainKey-Status: bad (test mode) Sometimes it says DomainKey-Status: good (test mode) All the other headers in the email are the same (besides expected time and message id differences). None of the email server configuration has changed. What would cause this problem?

    Read the article

  • Looking for Ubuntu 10.10 driver for GeForce GT 425M GPU.

    - by Fantomas
    It came with my Sony VAIO® VPCF133FX/H 16.4" Notebook. Ubuntu does suggest an NVIDIA driver for me, but when I install it, I cannot boot back in normally. I have to boot into a failsafe mode, then reset graphics setting to default, and reboot again. Right now I am stuck in 800 x 600 mode, but I would like to do better, and take advantage of my 1GB graphics memory :(. Please let me know if you have questions.

    Read the article

  • ls, rm, cd commands not working in SUSE LINUX

    - by Jak
    Hi All, Iam newbi to SUSE, I installed java in my SUSE linux Server edition, So i want to set the path in linux,So i created .bash_profile in in /root path using touch and added the path as "JAVA_PATH". When restart my linux the above command is not working and it show unknown command "JAVA_PATH", I can't able to boot in GUI mode, I can boot only in terminal mode, How to delete the file (.bash_profile in /root) ? And how to add java path in SUSE Note: Before all the commands are working fine Thanks in Advance, Jak...

    Read the article

  • SQL 2008 Replication

    - by sevenlamp
    I have replicated two database in SQL2008. The last two days the distribution database from publisher server changed to Suspect Mode and the replication process is down. I read a lot from Google and tried to repair, but without success. During my repairing process, the Distribution Database is has changed to Emergency mode. Can anyone please kindly suggest any solutions?

    Read the article

  • Backup of Xen servers and laptops with encryption

    - by Konrads
    Hello, I have the following backup objects: Multiple Xen Linux instances running on same box. A few laptops Windows that contain also private data that needs to be stored encrypted I have this backup media: A disk attached to the Xen box A disk available remotely for off-site backups I want to do daily-weekly-monthly backups of Xen systems and to back-up laptops in approximately same mode but in push mode (backup initiated by laptop) with encryption. Any good free solutions?

    Read the article

  • Linux compatible touchscreen monitor

    - by jrtokarz
    Can anybody recommend a linux compatible touchscreen monitor, the criteria are: 19inch or greater 1920x1080 or better only single touch required be able to operate in portait mode We currently have some IIyama Prolite MTS2250MS monitors but these do not natively support portait mode and we have had little success getting the touch functionality working in Linux (although they do report themselves as HID devices when plugged in). So an alternative to suggesting a monitor would be pointers to information on how we could get the IIyama monitor working in Linux.

    Read the article

  • Specifying a Postfix Instance to send outbound email

    - by Catherine Jefferson
    I have a CentOS 6.5 server running Postfix 2.6x (the default distribution) with five public IPv4 IPs bound to it. Each IP has DNS and rDNS set separately. Each uses a different hostname at a different domain. I have five Postfix instances, one bound to each IP, like this example: 192.168.34.104 red.example.com /etc/postfix 192.168.36.48 green.example.net /etc/postfix-green 192.168.36.49 pink.example.org /etc/postfix-pink 192.168.36.50 orange.example.info /etc/postfix-orange 192.168.36.51 blue.example.us /etc/postfix-blue I've tested each IP by telneting to port 25. Postfix answers and banners properly with the correct hostname. Email is received on all of these instances with no problems and is routed to the correct place. This setup, minus the final instance, has existed for a couple of years and works. I never bothered to set up outbound email to go through any but the main instance, however; there was no need. Now I need to send email from blue.example.us that actually leaves from that interface and IP, such that the Received headers show blue.example.us as the sending mailhost, so that SPF and DKIM validate, etc etc. The email that will be sent from blue.example.com is a feedback loop sent by a single shell account on the server (account5), an account that is dedicated to sending this email. The account receives the feedback loop emails from servers on other networks, saves the bodies of those emails, and then generates a new outbound email header, appends the saved body, and sends the email. It's sending by piping each email to sendmail -oi -t. We're doing it this way to mask the identities of the initial servers. The procmail script that processes these emails works correctly. However, I cannot configure this account to send email through the proper Postfix instance/IP/interface. The exact same account and script sends email through the main Postfix instance /etc/postfix without any issues. When I change MAIL_CONFIG to point to /etc/postfix-blue in either .bash_profile or the Procmail script that handles this email, though, I get this error: sendmail: fatal: User account5(###) is not allowed to submit mail I've read the manuals on Postfix.org, searched Google, and tried the suggestions in three previous answers here on ServerFault.com: Postfix - specify interface to deliver outbound mail on Postfix user is not allowed to submit mail Postfix rejects php mails I have been careful to stop and restart Postfix after each configuration change, and tested the results. Nothing has worked. The main postfix instance happily accepts outbound email from account5. The postfix-blue instance continues to reject email from account5 with the sendmail error above. As tempting as it is to blame machine hostility, I know that I must be missing something or doing something wrong. Does anybody have any suggestions as to what it might be? Please feel free to ask for further information about my setup if you need it. =-=-=-=-=-=-=-=-=-= At the request of the responder, here are main.cf and master.cf for a) the main postfix instance ("red.example.com") and b) the FBL instance ("blue.example.us") [NOTE: All parameters not specified below were left at the default Postfix 2.6 settings] MAIN: master.cf smtp inet n - n - - smtpd main.cf myhostname = red.example.com mydomain = example.com inet_interfaces = $myhostname, localhost inet_protocols = all lmtp_host_lookup = native smtp_host_lookup = native ignore_mx_lookup_error = yes mydestination = $myhostname, localhost.$mydomain, localhost local_recipient_maps = mynetworks = 192.168.34.104/32 relay_domains = example.com, example.info, example.net, example.org, example.us relayhost = [192.168.34.102] # Separate physical server, main mailserver. relay_recipient_maps = hash:/etc/postfix/relay_recipients alias_maps = hash:/etc/aliases alias_database = hash:/etc/aliases smtpd_banner = $myhostname ESMTP $mail_name multi_instance_wrapper = ${command_directory}/postmulti -p -- multi_instance_enable = yes multi_instance_directories = /etc/postfix-green /etc/postfix-pink /etc/postfix-orange /etc/postfix-blue FBL: master.cf 184.173.119.103:25 inet n - n - - smtpd main.cf myhostname = blue.example.us mydomain = blue.example.us <= Deliberately set to subdomain only. myorigin = $mydomain inet_interfaces = $myhostname lmtp_host_lookup = native smtp_host_lookup = native ignore_mx_lookup_error = yes mydestination = $myhostname local_recipient_maps = unix:passwd.byname $alias_maps $virtual_alias_maps mynetworks = 192.168.36.51/32, 192.168.35.20/31 <= Second IP is backup MX servers relay_domains = $mydestination recipient_canonical_maps = hash:/etc/postfix-blue/canonical virtual_alias_maps = hash:/etc/postfix-fbl/virtual alias_maps = hash:/etc/aliases, hash:/etc/postfix-blue/canonical alias_maps = hash:/etc/aliases, hash:/etc/postfix-blue/canonical mailbox_command = /usr/bin/procmail -a "$EXTENSION" DEFAULT=$HOME/Mail/ MAILDIR=$HOME/Mail smtpd_banner = $myhostname ESMTP $mail_name authorized_submit_users = multi_instance_name = postfix-blue multi_instance_enable = yes

    Read the article

  • Add Machine Key to machine.config in Load Balancing environment to multiple versions of .net framework

    - by davidb
    I have two web servers behind a F5 load balancer. Each web server has identical applications to the other. There was no issue until the config of the load balancer changed from source address persistence to least connections. Now in some applications I receieve this error Server Error in '/' Application. Validation of viewstate MAC failed. If this application is hosted by a Web Farm or cluster, ensure that configuration specifies the same validationKey and validation algorithm. AutoGenerate cannot be used in a cluster. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Web.HttpException: Validation of viewstate MAC failed. If this application is hosted by a Web Farm or cluster, ensure that configuration specifies the same validationKey and validation algorithm. AutoGenerate cannot be used in a cluster. Source Error: The source code that generated this unhandled exception can only be shown when compiled in debug mode. To enable this, please follow one of the below steps, then request the URL: Add a "Debug=true" directive at the top of the file that generated the error. Example: or: 2) Add the following section to the configuration file of your application: Note that this second technique will cause all files within a given application to be compiled in debug mode. The first technique will cause only that particular file to be compiled in debug mode. Important: Running applications in debug mode does incur a memory/performance overhead. You should make sure that an application has debugging disabled before deploying into production scenario. How do I add a machine key to the machine.config file? Do I do it at server level in IIS or at website/application level for each site? Does the validation and decryption keys have to be the same across both web servers or are they different? Should they be different for each machine.config version of .net? I cannot find any documentation of this scenario.

    Read the article

  • seeking VPS Hosting advice

    - by jergw
    What is the best price, best value, for Linux VPS hosting in British Columbia, Canada? looking for something that can handle Perl/PHP, and admin user control of library/module installation. BTW: Is it possible to get a dual setup...half windows mode server, half Linux mode server? Thanks in advance for all your responses.

    Read the article

  • How to remove RAID flag on unstriped drive without losing data?

    - by Alex Folland
    I have a Gigabyte Z68X-UD4-B3 motherboard. It advertises this new thing called "XHD", which is like RAID but makes a SSD and traditional-style drive work together to enable high speed with high capacity. I don't want to use this feature, and I already have Windows 7 64 installed without using this feature. When I first installed my 2 hard drives (1 SSD and 1 traditional-style drive) in my machine and booted it up for the first time, it ran a program from the mobo that asked me if I wanted to set up XHD. Thinking it would go to some config screen, I said yes. It immediately started doing something with my drives and finished. I considered that strange, but figured it wouldn't matter when I simply install Windows onto my SSD only. I now have my BIOS and Windows running in AHCI mode with no RAID arrays and separate drives. My SSD is one of those new Corsair Force GT drives which loses power every so often, causing Windows to BSOD. I've figured everything out about this problem, including installing the latest firmware from Corsair, and the only way to fix it at this point is by installing Intel Rapid Storage Technology to control AHCI instead of Windows, since the Windows AHCI driver disables the drive's power every once in a while and can't be configured not to do so. I've tried installing Intel Rapid Storage Technology. When I reboot my machine after doing so, it BSODs just after the Windows logo. I've figured out this is because my SSD and my traditional drive are flagged as RAID, as seen in the "Intel Matrix Storage Manager" program found by switching the BIOS hard drive handling to "RAID" mode. This is due to the XHD auto-config program I mentioned earlier. Normally, the BIOS is set to AHCI, and when the drives boot in AHCI mode, they work perfectly. So, I've concluded the data is stored in AHCI mode but the drives' flags are set to RAID. I've figured out that I can accomplish my objective by using the "Intel Matrix Storage Manager" program on the mobo (with "Reset disks to non-RAID"), but doing so would cause it to completely wipe the drives I select. I want to simply toggle these flags from RAID to AHCI so Intel Rapid Storage Technology doesn't fail and cause a BSOD upon booting, but without wiping the drives.

    Read the article

  • How to make it easier when using the vim command in unix?

    - by Mitral
    Recently i try to learn something about the unix. when i try to edit something using the vi command, it is very difficult for me since i have to switch the edit mode and control mode time by time. It is very inconvenient. Is it that i miss something or it is originally like that? Is there anyway to improve that? Thank you :)

    Read the article

  • What is the correct network configuration for a devStack VM (virtualbox)?

    - by Olivier
    Usually when I setup a new Ubuntu VM, i keep the eth0 in NAT mode to get the internet & I add a eth1 interface in HostOnly mode so that I can ssh. But using this devStack guide : Running a Cloud in a VM, it looks like it tried to use eth0 as the public interface (install got stuck because eth0 lost the network). I know an OpenStack setup usually requires two NICs, so I'm wondering what is the correct configuration for my VM.

    Read the article

  • Skype silent chat message

    - by D Moberg
    Reason: I have a contact that I know is busy, but still want notifications so he is in "online"-mode and not DND-mode. I want to write "OK" to him, without having to disturb him (having him to open and look in skype to see if it was something important, which it is not). Question: Is there any way to send a message that won't trigger a notification at the receiver's end? Something like a "silent message".

    Read the article

  • How do I use a period in a Quicksilver object (search for a file with a period)?

    - by studgeek
    How do I use a period in a Quicksilver object to do things like search for a file with a period? By default pressing period anywhere in an object causes Quicksilver to switch to text mode. Optimally I would like period to only enter text mode when its at the start of the object. Or perhaps there is a wildcard I can use (* doesn't seem to work and . obviously doesn't :). Or perhaps there is an escape sequence for period?

    Read the article

  • Recovering Root Password

    - by Melvin
    This hasn't happened to me yet but I am documenting this process just in case. Let's say I can't remember my root password for my linux server. Every example of this scenerio that I can find says to first boot into single user mode. What if my server is currently running in multiuser mode and I have no sessions open as root. How exactly do I order an orderly shutdown without root access so that I can begin the password recovery process?

    Read the article