  • How to setup whole-disk encryption with dual boot on a MacBook Pro (generation 9,2 with 12.04)

    - by blueyed
    I can install Ubuntu 12.04 on the MacBook when using the "noapic" kernel boot option, using the alternate amd64+mac image (from http://cdimage.ubuntu.com/releases/12.04/release/ ). But after installation the screen turn sblack after trying to boot "Windows" (as named in the boot menu that shows up when holding Option/Alt during startup). I want to use whole-disk encryption and given that only one free partition is available, I have setup LVM to do so: - vg0 contains bootlv and cryptlv - in cryptlv I have setup encryption with another LVM volume group (vg1, which holds swaplv, rootlv and homelv) I have not installed Grub during installation (because I was not sure about the partition) and when trying to install it later on /dev/sda4 (which contains the outer LVM) it complained that it could not determine the file system, and --force did not help either. The black screen / behavior looks similar to starting the installer without enabling the noapic option.

    Read the article

  • How do you use the hard disk of Ubuntu when u have installed from wubi?

    - by Nitz
    I have installed Ubuntu 11.10 inside Windows 7 ('C' Drive) by using wubi. But now i wanted to re-install Windows 7. But whatever the data and configurations are done in ubuntu that i don't want to delete. So if i move that Ubuntu Folder from C drive to any other drive then re-install windows 7. Then How i will get back ubuntu 11.10 ? How can I get back my data and everything of ubuntu after re-installing windows. Is there any way that i can use my hard disk created in ubuntu ?

    Read the article

  • What are the benefits of a disk install vs. Wubi? And can I migrate my settings easily?

    - by Alex Bixel
    I chose to do the Wubi install because it was short, simple, and easy to reverse (no messing with partitions required). To be honest, I can handle the lack of a hibernate function. I haven't really heard many other benefits of installing on a separate partition than hibernation and negligibly faster hard disk read/write. Yet almost everyone I encounter seems to have opted for the disk installation. Are there more benefits I should be aware of, especially as a college student who wants a fast, efficient machine for documents, web browsing, etc. (nothing big like gaming, I can run that on Windows)? Also, I have a fair amount of settings and packages installed that I spent a bit of time on and would rather not have to do again. Is there any way I can migrate all of these settings from the virtual disk on my C:/ drive (Wubi installation) to the disc installation in another partition? (I have a 16GB USB drive if that'll do the trick)

    Read the article

  • How to add UTF-8 support to my hard disk in fstab?

    - by punkmexic
    I use Ubuntu (Spanish language). Sometimes I get this error when I use special characters (codification error) so I read that if I edit a file of my hard disk by using gedit /etc/fstab and adding utf8 I can fix it.... I had this line: UUID=bfb5b95e-bf68-464a-8abf-d6027b039fa4 / ext4 errors=remount-ro 0 1 I adeed utf8 like this: UUID=bfb5b95e-bf68-464a-8abf-d6027b039fa4 / ext4 errors=remount-ro,iocharset=utf8 0 1 But I messed my Ubuntu and I can't log in now to my Ubuntu so im using live session... so I'll have to remove that code in order to be able to use my Ubuntu again. Can someone tell me how that line should look like?

    Read the article

  • what the best and simplest way to find out whether a volume need defrag?

    - by r9r9r9
    I am writing a application that monitor the system's health, user should know when they need to defrag the volumes. What I am thinking is calling the "defrag.exe /A" then analyze the output result to see whether it contains "You do not need to defragment this volume." But it's slow and very bad, I fount that the "Analyze" is really quick on the MyDefrag.exe. Anyone could tell me what's the best and simplest way?

    Read the article

  • Unique DVD info?

    - by acidzombie24
    I was wondering, is there some type of disc ID i can use to search in my database to see if that disc is has been scanned or not? All disc were created by me typically burnt on windows. -edit- I could compare write time and volume label to see if the disc has been scanned but i notice if i put in certain commercial disc that fields are blank or wrong causing many false positives (i once had the time set to the future, i dont know if people want to archive the contents of files on a commercial disc in my app).

    Read the article

  • How to recover disk and files after 10.04 boot failure?

    - by K R Jawaharlal
    I have a 1TB HDD with four Windows XP partitions and a 120GB HDD with 10.04. While working in Ubuntu, due to delay and failure to shutdown, I switched off the system. Next it failed to boot in Ubuntu and stopped at initramfs. After that, I tried to repair from the booting stage. By mistake instead of hdd no I used partition no. This damaged the Windows also. Then Windows XP was reloaded and is running. When I boot with 12.04, it is able to detect the 120GB HDD, but, it is unable to mount. I am unable to access the files. I would like to revive the disk and recover files. Would appreciate any help.

    Read the article

  • Way to know if two partitions are in one physical hard disk without WMI?

    - by Alon
    Hey. I have those partitions (in Windows) for example: Hard Disk 1 - Partition C, Partition D Hard Disk 2 - Partition E Is there any way in a program language to know if for example partition C and partition D are in one physical hard disk without WMI? I don't want to use WMI because it's slow - for this example, it took for me 0.5 seconds. I need it to be fast. Thank you.

    Read the article

  • FileSystemWatcher Work is Done?

    - by Snowy
    I setup a FsWatcher on a local filesystem directory. I only want to know when files are added to the directory so they can be moved to another filesystem. I seem to be able to detect when the first file is in, but actually I want to know when all files from a given copy operation are done. If I used Windows Explorer to copy files from one directory to another, Explorer would tell me that there are n seconds left in the transfer, so while there is some activity for the begin-transfer and end-transfer for each file, it appears that there is something for the begin-transfer and end-transfer for all files. I wonder if there is something similar that I can do just with the .NET Framework. I would like to know when "all" files are in and not just a single file in a "transaction". If there is nothing baked in, maybe I should come up with some kind of waiting/countering in order to only do my activity when a job is "done". Not sure if I'm making 100% sense on this one, please anyone comment. Thanks.

    Read the article

  • lib to read a DVD FS (data disc)

    - by acidzombie24
    I am thinking i might want to port a lib to read a DVD filesystem. I am not talking about movies but datadisc. Theres existing code for me to do raw reads from the disc. I need code that request this data and allow me to browse files on the disc. What lib can i use for this? -edit- NOTE: I am using an OSless hardware. Ppl seem to miss that but Alnitak caught it and gave me a great answer :)

    Read the article

  • Scalable stl set like container for C++

    - by Pqr
    Hi, I need to store large number of integers. There can be duplicates in the input stream of integers, I just need to store distinct amongst them. I was using stl set initially but It went OutOfMem when input number of integers went too high. I am looking for some C++ container library which would allow me to store numbers with the said requirement possibly backed by file i.e container should not try to keep all numbers in-mem. I don't need to store this data persistently, I just need to find unique values amongst it.

    Read the article

  • ?????Exadata????

    - by Liu Maclean(???)
    ??check Exadata Image & OS versions , GI & DB patches sundiag exacheck cellserv ==> imageinfo dbhost ==> /usr/local/bin/imagehistory Also check the version of the switch. Login to Switch and execute the following command [root@myswitch-1 sbin]# version [root@dmorlsw-ib2 sbin]# cd /usr/local/bin [root@dmorlsw-ib2 bin]# ls -lrt version -rwxr-xr-x 1 root root 20356 Apr 4 2011 version Output will look as below. [root@dmorlsw-ib2 ~]# version SUN DCS 36p version: 1.3.3-2 Build time: Apr 4 2011 11:15:19 SP board info: Manufacturing Date: 2009.05.05 Serial Number: "NCD3X0178" Hardware Revision: 0x0006 Firmware Revision: 0x0102 BIOS version: NOW1R112 BIOS date: 04/24/2009 ib8# cat /sys/class/infiniband/is4_0/fw_ver 7.2.300 ib8 # cat /sys/class/dmi/id/bios_version NOW1R112 ib8 # nm2version NM2-36p version: 1.0.1-1 Build time: Sep 14 2009 12:52:51 ComExpress info: Manufacturing Date: 2009.08.19 Serial Number: Hardware Revision: 0x0006 Firmware Revision: 0x0102 { case `uname` in Linux ) ILOM="/usr/bin/ipmitool sunoem cli" ;; SunOS ) ILOM="/opt/ipmitool/bin/ipmitool sunoem cli" ;; esac ; ImageInfo="/opt/oracle.cellos/imageinfo" ; uname -srm ; head -1 /etc/*release ; uptime | cut -d, -f1 ; $ILOM "show /SP system_description system_identifier" | grep = ; $ImageInfo -activated -node -status -ver | grep -v ^$ ; } | tee /tmp/ExaInfo.log $GRID_HOME/OPatch/opatch lsinv -all -oh $GRID_HOME | tee /tmp/OPatchInv.log $ORACLE_HOME/OPatch/opatch lsinv -all | tee -a /tmp/OPatchInv.log cat /tmp/ExaInfo.log Linux 2.6.18-128.1.16.0.1.el5 x86_64 ==> /etc/enterprise-release <== Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) ==> /etc/redhat-release <== Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) 20:37:56 up 458 days system_description = SUN FIRE X4170 SERVER, ILOM v3.0.6.10.b, r52264 system_identifier = Sun Oracle Database Machine Active image version: 11.2.1.2.3 Active image activated: XXXX-XX-XX 12:27:12 +0800 Active image status: success Active node type: COMPUTE Inactive image version: undefined FileName: OPatchInv.log ---------------- ... Oracle Home       : /u01/app/11.2.0/grid Central Inventory : /u01/app/oraInventory   from           : /etc/oraInst.loc OPatch version    : 11.2.0.1.2 OUI version       : 11.2.0.1.0 OUI location      : /u01/app/11.2.0/grid/oui ... -------------------------------------------------------------------------------- List of Oracle Homes:   Name                                       Location   Ora11g_gridinfrahome1         /u01/app/11.2.0/grid   OraDb11g_home1                  /u01/app/oracle/product/11.2.0/dbhome_1 -------------------------------------------------------------------------------- Installed Top-level Products (1): Oracle Grid Infrastructure                                           11.2.0.1.0 ... Interim patches (2) : Patch  9524394      : applied on Thu Jun 03 20:46:05 CST 2010 ... {TRACKING BUG FOR 11.2.0.1 DB MACHINE BUNDLE PATCH 3} Patch  9455587      : applied on Fri Apr 02 18:27:47 CST 2010 ... {MERGE REQUEST ON TOP OF 11.2.0.1.0 FOR BUGS 8483425 8667622 8702731 8730804} Rac system comprising of multiple nodes  Local node = dbserv01  Remote node = dbserv02  Remote node = dbserv03  Remote node = dbserv04 -------------------------------------------------------------------------------- OPatch succeeded. ... Oracle Home       : /u01/app/oracle/product/11.2.0/dbhome_1 ... Oracle Database 11g                                                  11.2.0.1.0 ... Interim patches (5) : Patch  8888434      : applied on Sat Jan 08 00:27:33 CST 2011 ... {AIX-ASM-CF: LMHB TERMINATE INSTANCE WHEN OFFLINE ONE FAILGROUP IN ASM DG} Patch  8730312      : applied on Thu Jun 03 21:30:03 CST 2010 ... {FWD MERGE FOR BASE BUG 8715387 FOR 12G} Patch  9502717      : applied on Thu Jun 03 21:25:54 CST 2010 ... {LMS HIT ORA-600 [KJBLDRMNEXTPKEY:SEEN] AND CRASHED THE INSTANCE} { + same 2 as GI above} ?? cell server Cache Policy cell08# MegaCli64 -LDInfo -Lall -aALL | grep 'Current Cache Policy' Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU cell09# MegaCli64 -LDInfo -Lall -aALL | grep 'Current Cache Policy' Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Cache policy is in WB Would recommend proactive  battery repalcement. Example : a. /opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp  -Cache -LALL -aALL ####( Will list the cache policy) b. /opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp  -WB  -LALL -aALL ####( Will try to change teh policy from xx to WB)     So policy Change to WB will not come into effect immediately     Set Write Policy to WriteBack on Adapter 0, VD 0 (target id: 0) success     Battery capacity is below the threshold value ??cell BBU??????: cell08# /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -a0 BBU status for Adapter: 0 BatteryType: iBBU Voltage: 4061 mV Current: 0 mA Temperature: 36 C BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No Remaining Capacity Low : Yes Periodic Learn Required : No Battery state: GasGuageStatus: Fully Discharged : No Fully Charged : Yes Discharging : Yes Initialized : Yes Remaining Time Alarm : No Remaining Capacity Alarm: No Discharge Terminated : No Over Temperature : No Charging Terminated : No Over Charged : No Relative State of Charge: 99 % Charger System State: 49168 Charger System Ctrl: 0 Charging current: 0 mA Absolute state of charge: 21 % Max Error: 2 % Exit Code: 0x00 ????BBU ??: dcli -g ~/cell_group -l root -t '{ uname -srm ; head -1 /etc/*release ; uptime | cut -d, -f1 ; imagehistory ; ipmitool sunoem cli "show /SP system_description system_identifier" | grep = ; ipmitool sunoem cli "show /SP/policy FLASH_ACCELERATOR_CARD_INSTALLED /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -a0 | egrep -i 'BBU|Battery|Charge:|Fully|Low|Learn' ; }' | tee /tmp/ExaInfo.log Target cells: ['cellserv01', 'cellserv02', 'cellserv03', 'cellserv04', 'cellserv05', 'cellserv06', 'cellserv07'] cellserv01: Linux 2.6.18-128.1.16.0.1.el5 x86_64 cellserv01: ==> /etc/enterprise-release <== cellserv01: Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) cellserv01: cellserv01: ==> /etc/redhat-release <== cellserv01: Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) cellserv01: 01:17:39 up 635 days cellserv01: Version : 11.2.1.2.1 cellserv01: Image activation date : 2011-03-25 11:59:34 -0800 cellserv01: Imaging mode : fresh cellserv01: Imaging status : success cellserv01: cellserv01: Version : 11.2.1.2.3 cellserv01: Image activation date : 2011-04-13 12:15:46 +0800 cellserv01: Imaging mode : patch cellserv01: Imaging status : success cellserv01: cellserv01: Version : 11.2.1.2.6 cellserv01: Image activation date : 2011-05-27 23:08:22 +0800 cellserv01: Imaging mode : patch cellserv01: Imaging status : success cellserv01: cellserv01: system_description = SUN FIRE X4275 SERVER, ILOM v3.0.6.10.b, r52264 cellserv01: system_identifier = Sun Oracle Database Machine cellserv01: Connected. Use ^D to exit. cellserv01: -> show /SP/policy FLASH_ACCELERATOR_CARD_INSTALLED cellserv01: show: No matching properties found. cellserv01: cellserv01: -> Session closed cellserv01: Disconnected cellserv01: BBU status for Adapter: 0 cellserv01: BatteryType: iBBU cellserv01: BBU Firmware Status: cellserv01: Learn Cycle Requested : No cellserv01: Learn Cycle Active : No cellserv01: Learn Cycle Status : OK cellserv01: Learn Cycle Timeout : No cellserv01: Battery Pack Missing : No cellserv01: Battery Replacement required : No cellserv01: Remaining Capacity Low : Yes cellserv01: Periodic Learn Required : No cellserv01: Battery state: cellserv01: Fully Discharged : No cellserv01: Fully Charged : Yes cellserv01: Relative State of Charge: 99 % cellserv01: Absolute state of charge: 21 % dcli -l root -g /root/all_group '/opt/MegaRAID/MegAaCli/MegaCli64 -AdpBbuCmd -a0' > BBU.out check ipmi: dcli -g ~/cell_group -l root -t '{ > ipmitool sunoem cli "show /SP/policy FLASH_ACCELERATOR_CARD_INSTALLED" | grep = ; MegaCli64 -LDInfo -Lall -aALL | grep 'Current Cache Policy' ; }' | tee /tmp/ExaCells.log

    Read the article

  • What is the differences between a Remote File Share Witness Quorum and a Disk Witness Quorum?

    - by arex1337
    Say you set up a Windows Server Failover Cluster consisting of two nodes, on Windows Server 2008 R2 Enterprise. Now when you want to configure quorum you can use either a remote shared folder, or a shared disk (unless your nodes are separated geographically). I'd love to know more about when to use a disk witness and when to use a file share witness. What are the differences? Does it matter at all?

    Read the article

  • How to stop Time Machine on Mac use of removable disk?

    - by ablmf
    One of my friend recently bought a Mac and somehow when she connect her removable disk to the computer, Time Machine took control of this device uses it as backup device automatically -- she could not use the disk for other purpose any more. When we connect it to windows, it could not be recognize any more. How can we get it back under control?

    Read the article

  • How to know disk quota on network share in windows?

    - by myforwik
    I connect to a share on a windows server and I have a quota of unknown size. All the tools I have seen are reporting the disk size/disk free space, not the quota size for myself. The only way I can figure out my quotas is to keep writing junk until I reach the quota. There must be a better way than this? My PC is windows XP and the servers are mainly 2003server.

    Read the article

  • convert full-disk RAID5 array to partition-based array?

    - by Delan Azabani
    I have a RAID 5 array, md0, with three full-disk (non-partitioned) members, sdb, sdc, and sdd. My computer will hang during the AHCI BIOS if AHCI is enabled instead of IDE, if these drives are plugged in. I believe it may be because I'm using the whole disk, and the AHCI BIOS expects an MBR to be on the drive (I don't know why it would care). Is there a way to convert the array to use members sdb1, sdc1 and sdd1, partitioned MBR with 0xFD RAID partitions?

    Read the article

  • On Solaris, how do you mount a second zfs system disk for diagnostics?

    - by Matt Ball
    (Cross posted from Stack Overflow 1) I've got two hard disks in my computer, and have installed Solaris 10u8 on the first and Opensolaris 2010.3 (dev onnv_134) on the second. Both systems uses ZFS and were independently created with a zpool name of 'rpool'. While running Solaris 10u8 on the first disk, how do I mount the second ZFS hard disk (at /dev/dsk/c1d1s0) on an arbitrary mount point (like /a) for diagnostics?

    Read the article

  • How to write image of a floppy disk to a flash drive?

    - by Usman Ajmal
    I have created an image of a floppy disk by executing: dd if=/dev/fd0 of=/home/myFloppy.img My floppy disk is no more working now. So I am thinking now if it's possible to write the image of that floppy to a flash drive and then i may boot my machine from the flash drive. My machine's BIOS has the option of 'Boot from USB'.

    Read the article

  • Has anyone managed to virtualise Windows 7 on a physical disk?

    - by Stavros
    I have Windows 7 installed on a partition and running fine, but I want to access them from my Ubuntu installation with VirtualBox. I have created the virtual disk file and everything, but Windows bluescreens after a bit of loading with error 0000007B (it can't find the disk or something). Has anyone managed to solve this problem?

    Read the article

  • What is the best way to secure MySQL data on a laptop *without* whole-disk-encryption?

    - by GJ
    I need to have the mysql data on my laptop stored in an encrypted state so that in case of the laptop being lost/stolen it will extremely difficult to recover the data without the password. I don't wish to use whole disk encryption, due to the performance impact it will have on other disk-intensive programs' usage. What could be the ideal solution for me balancing security and performance? Thanks!

    Read the article

  • How to know which disk has failed on a Mirrored Raid? marked as DR0

    - by Saariko
    Our 2ndry DC, which is on a W2K8R2 Mirrored software raid has lost it's sync, and disk management displays the failed redundancy error How do I know which of the disks has failed? (beside to try and replace one - and see if it loads and syncs) On the device manager, under disks I see both disks, one of them has an icon of: Disable, while the other doesn't Event log displays an event id 7 - bad block on Hard disk DR0 The thing is that looking in device manager, both disks are located in '0' location, which is bizzare

    Read the article