  • PC -> TV HDMI suddenly doesn't work, any other option does

    - by XSlicer
    So my parents wanted to connect their PC to their TV, so they bought a 10m (35 ft) cable. It all worked perfectly. Then my mom tripped over the cable, breaking it. She somehow got a free replacement, but at the same time some more expensive one from an uncle. Now the problem is that this suddenly doesn't work anymore (TV saying "Format not supported"). I've tried several other things to pinpoint the actual problem, but none brought me something conslusive: PC (hdmi) to TV doesn't work (both cables) PC (hdmi) to TV doesn't work (short cable) Laptop (hdmi) to TV work (same cables) BluRay (hdmi) to TV works (same cables) PC (hdmi) to monitor works (same cables) PC (DVI w/ adapter HDMI) to TV works (same cables) I've tried different ports, tried Linux, reinstalling drivers (the graphics card is internal using an i5 sandy bridge. Normally it's running Windows 7 Home Prem, the TV being a Philips 37PFL7605H). So basically, everything works, except that thing what we want. The only things I am thinking of is that the sound is interfering or that the HDMI-output is somehow broken. Or is it anything else? I'm kind of lost.

    Read the article

  • Unable to connect via NetBIOS Name

    - by grom
    I can't connect to machines/shares by NetBIOS names. Below is console output showing the problem. C:\>nbtstat -n Local Area Connection: Node IpAddress: [192.168.1.100] Scope Id: [] NetBIOS Local Name Table Name Type Status --------------------------------------------- BEAST <00> UNIQUE Registered WORKGROUP <00> GROUP Registered BEAST <20> UNIQUE Registered WORKGROUP <1E> GROUP Registered WORKGROUP <1D> UNIQUE Registered ..__MSBROWSE__.<01> GROUP Registered C:\>nbtstat -A 192.168.1.3 Local Area Connection: Node IpAddress: [192.168.1.100] Scope Id: [] NetBIOS Remote Machine Name Table Name Type Status --------------------------------------------- BRCLAPTOP <00> UNIQUE Registered WORKGROUP <00> GROUP Registered BRCLAPTOP <20> UNIQUE Registered WORKGROUP <1E> GROUP Registered MAC Address = 00-1C-BF-14-B8-6E C:\>ping beast Pinging beast [fe80::59b8:179f:b90b:a63f%11] with 32 bytes of data: Reply from fe80::59b8:179f:b90b:a63f%11: time<1ms Reply from fe80::59b8:179f:b90b:a63f%11: time<1ms Reply from fe80::59b8:179f:b90b:a63f%11: time<1ms Reply from fe80::59b8:179f:b90b:a63f%11: time<1ms Ping statistics for fe80::59b8:179f:b90b:a63f%11: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms C:\>ping brclaptop Ping request could not find host brclaptop. Please check the name and try again. C:\>nbtstat -a brclaptop Local Area Connection: Node IpAddress: [192.168.1.100] Scope Id: [] Host not found.

    Read the article

  • Linux Software RAID1: How to boot after (physically) removing /dev/sda? (LVM, mdadm, Grub2)

    - by flight
    A server set up with Debian 6.0/squeeze. During the squeeze installation, I configured the two 500GB SATA disks (/dev/sda and /dev/sdb) as a RAID1 (managed with mdadm). The RAID keeps a 500 GB LVM volume group (vg0). In the volume group, there's a single logical volume (lv0). vg0-lv0 is formatted with extfs3 and mounted as root partition (no dedicated /boot partition). The system boots using GRUB2. In normal use, the systems boots fine. Also, when I tried and removed the second SATA drive (/dev/sdb) after a shutdown, the system came up without problem, and after reconnecting the drive, I was able to --re-add /dev/sdb1 to the RAID array. But: After removing the first SATA drive (/dev/sda), the system won't boot any more! A GRUB welcome message shows up for a second, then the system reboots. I tried to install GRUB2 manually on /dev/sdb ("grub-install /dev/sdb"), but that doesn't help. Appearently squeeze fails to set up GRUB2 to launch from the second disk when the first disk is removed, which seems to be quite an essential feature when running this kind of Software RAID1, isn't it? At the moment, I'm lost whether this is a problem with GRUB2, with LVM or with the RAID setup. Any hints?

    Read the article

  • 1080p monitor: connected through VGA - perfect, HDMI - awful

    - by develroot
    When I connect my 23" monitor (1920x1080) to my pc through HDMI, I encourage some problems. It's not full screen That's it. There are ~1cm black borders on right and left side and ~0,5cm black borders on the top and the bottom of the monitor. That's pretty frustrating. I tried adjusting overscan, but I can't mannualy type the % of overscan that I need. I can only select between ex. 8 and 10% in AMD Vision Engine Control center, but what I need is 9%. Next, even if i select 10% and the image fits all the corners, but after log off all the settings are lost and I have to do it again and again. Text, images, everything looks blurry That surprised me a lot. Should'nt HDMI quality be better than VGA's one? When connected through HDMI, the text isn't readable. It's like a very low refresh rate, although i'm running at 60Hz. Also the text has something like little shadows, very very annoying. Are there any tips to get the same quality as with VGA, with HDMI ? (running on integrated ATI Radeon HD4200, which, appearently, is the best card I have ever seen in terms of integrated ones)

    Read the article

  • Requests are making it to my app server, but not into node.js -- why?

    - by Zane Claes
    I detailed in this question on StackOverflow how some random requests are not making it from the client to my Node.js app server, resulting in a gateway timeout. In summary, identical requests are, at random, not even making it far enough to trigger a console.log() in my first line of express middleware. I need to narrow down the problem, though, to find out WHERE the traffic is being lost and it was suggested that I try a packet sniffer on my app servers. Here's my setup: 2x Load Balancers (m1.larges) 2x node.js servers (also m1.large) Here's what's interesting/unusual: the node.js servers started as PHP servers with an Apache stack and continue to serve PHP files for my domain (streamified.me). However, I use a little httpd.conf magic on the app servers so that requests to api.streamified.me get routed over port 8888 to the node.js server: RewriteCond %{HTTP_HOST} ^api.streamified.me RewriteRule ^(.*) http://localhost:8888$1 [P] So, the request hits the load balancer = goes to an app server = gets routed to port 8888 if it's intended for the API = gets handled by node.js So, in the same httpd.conf file, I turned on RewriteLogLevel 5 and then created a simple PHP+CURL script on my localhost to hit my api.streamified.me with a random URL (which should cause node.js to trigger a simple "not found" response) until it resulted in a Gateway timeout. Here, you can see that it has happened -- and the rewrite log shows that the request was definitely received by the app server and forwarded to port 8888... but it was never received by node.js (or, at least, the first line of code in the first line of middleware never gets it...) Image Link: http://i.stack.imgur.com/3OQxS.png

    Read the article

  • MySQL ADO.NET Connector & MSSQL Integration Services

    - by user1114330
    Here I am, day three... attempting to sync a data view on a Windows Vista box (64 bit) running MSSQL 2012 and Visual Studio 2010. Sanity is slipping and hunger for progress fills my attention. I went through hell trying to get the MySQL ODBC drivers to get the job but to no avail...everyone seems to be lost and all the threads I can find are solutions that do not work for me. The problem: System DSN's not being seen by SSIS. SSIS DSN Not Showing as ODBC Data Source I make the decision to try out the ADO.NET connector...and to my surprise it is actually in the selection list in data sources in SSIS. So I take off running to create a Data Flow Task, create an ADO.NET Source (a local MSSQL DB)...all is good as usual. Then I move swiftly to creating a ADO.NET Destination, enter my credentials...wow, I am selecting a database finally on my linux server! Happy thinking that I finally have figured a way to get the job done. Then I move to mappings...nope, something is wrong...I am getting an error that hurts my eyes: Pipeline component has returned HRESULT error code 0xC0208457 from a a method call. Error at Data Flow Task [ADO NET Destination [81]]: Failed to get properties of external columns. The table name you entered may not exist or you do not have SELECT permission on the table object and an alternative attempt to get column properties through connection has failed. Detailed error messages are" You have an error in your SQL syntax check the manual that corresponds to your MySQL server version for the right syntax to use near "database".tablename" at line 1. The descriptor files on path C:\Program Files (x86)\Microsoft SQL Server\110\DTS\ProviderDescriptors\ does not contain schema information for connection of type MySQL.Data.MySqlClient.MySqlConnection. So it looks like it can't the information and therefore I cannot map the tables properly. Any ideas on this would be ultra helpful...thanks in advance to All!

    Read the article

  • Not able to access Silverlight.net and ONLY Silverlight.net - All other domains work!

    - by Sootah
    Alrighty folks, I have an extremely odd problem. I am able to surf the web fine with one odd (and really annoying at the moment) exception: Microsoft's Silverlight.net. Every other site that I go to works just fine. This is quite frustrating because I'm in the middle of programming a web app in Silverlight 4.0, and whenever I do a search for any code examples, tutorials, or whatnot at least 50% of the results are hosted in the silverlight.net forums. The error message that I get is: Oops! Google Chrome could not find www.silverlight.net It doesn't work in my other browsers either (both IE and FireFox). What's odd, is that while the error message would lead me to assume it's a DNS error, I can ping the URL just fine. C:\Users\The Doot>ping silverlight.net Reply from 206.72.125.201: bytes=32 time=106ms TTL=106 Reply from 206.72.125.201: bytes=32 time=106ms TTL=106 Reply from 206.72.125.201: bytes=32 time=106ms TTL=106 Reply from 206.72.125.201: bytes=32 time=106ms TTL=106 Ping statistics for 206.72.125.201: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 103ms, Maximum = 110ms, Average = 106ms I've checked my HOSTS file, and there's nothing that refers to ANY Microsoft URL in there. What could be causing this!?? More importantly, how do I fix it? Just for kicks, I've even included the results of a traceroute here for your enjoyment. OS: Windows 7 Ultimate Thanks in advance! -Sootah

    Read the article

  • RPC Server Unavailable on Hyper-V cluster when moving resources after the host adapter has failed

    - by Doug Luxem
    On a Windows 2008 R2 SP1 cluster running Hyper-V, a lost network connectivity on the primary host interface. The interface was rapidly flapping up and down, and this was later determined to be caused by a faulty switch port. As this was a clustered server, the host interface was not fault tolerant (seeing as how the whole server was fault tolerant), so connectivity to the host was going up and down. The Hyper-V guests were completely unaffected by the network outage as they used a dedicated trunk on the server separate from the host interface. Additionally, dedicated interfaces for the cluster and live migration networks were fine. In order to diagnose the server, I tried to move all resources (Hyper-V Guests) to other nodes through Failover Cluster Manager. These moves failed with an error RPC Server Unavailable. The only way to move resources was by shutting down the guests, stopping the cluster service on the Node A, allowing other nodes to take ownership of the resources, and restarting the guests. A few other notes: All nodes have Client for MS Networks and File & Printer Sharing enabled on the Cluster and LM networks. Node A was accessible over cluster and LM networks from other nodes (these are private, cluster-only networks); pingable, CIFs, etc. Accessing \\NODEA is done over the Host adapters, as you would expect in this case and is the reason for the RPC Server Unavailable error with that adapter being down. My questions here are - Is there a way to still use Live Migration in a failure scenario such as this to prevent shutting down the Hyper-V guests? How can the network be reconfigured in the future so that the cluster service attempts to use the cluster and/or live migration networks to issue the RPC requests?

    Read the article

  • Creating "save as" functionality to .eml file in AppleScript

    - by unieater
    I'm new to AppleScript and trying to figure out how to save a Mail.app message as an .eml message. Ideally, I would like it to act similar to the Mail menu bar actions, in which it saves the message and the attachments together. The workflow is that you have a selection in Mail, hit a hotkey and the function creates a filename (newFile) for the email to be saved. I just need help with how to save the message to the path (theFolder) in an .eml format. tell application "Mail" set msgs to selection if length of msgs is not 0 then display dialog "Export selected message(s)?" if the button returned of the result is "OK" then set theFolder to choose folder with prompt "Save Exported Messages to..." without invisibles repeat with msg in msgs -- determine date received of msg and put into YYYYMMDD format set msgDate to date received of msg -- parse date SEMversion below using proc pad2() set {year:y, month:m, day:d, hours:h, minutes:min} to (msgDate) set msgDate to ("" & y & my pad2(m as integer) & my pad2(d)) -- assign subject of msg set msgSubject to (subject of msg) -- create filename.eml to be use as title saved set newFile to (msgDate & "_" & msgSubject & ".eml") as Unicode text -- copy mail message to the folder and prepend date-time to file name -- THIS IS WEHRE I AM COMPLETE LOST HOW SAVE THE EMAIL into theFolder end repeat beep 2 display dialog "Done exporting " & length of msgs & " messages." end if -- OK to export msgs end if -- msgs > 0 end tell on pad2(n) return text -2 thru -1 of ("00" & n) end pad2

    Read the article

  • Ubuntu in failed state after upgrade from 10.04 to 10.10 - How to recover?

    - by Harvey
    I was running Ubuntu 10.04 and attempted to upgrade to 10.10. I have a really slow connection (DSL 128kbits/sec) and copying the upgrade files took about 26 hours. I of course let it run unattended. When I came back, I notice the following 3 dlgs: 1. Could not install the upgrades The upgrade has aborted. Your system could be in an unusable state. A recovery will run now (dpkg -- configure -a). 2. gpk-update-icon Distribution upgrades available maverick 10.10 (stable) [more information] [Do no show this again] [Cancel] [Ok] 3. gpk-update-icon Security updates available The following important updates are available for your computer: libwebkit-1.0-2-dbg - Web content engine library for Gtk+ - Debugging symbols libcupsimage2 - Common UNIX Printing System(tm) - Raster image library ... What is the best response to all of this? I went through something similar in an attempted network upgrade from 8.04 to 10.04 and had to reload the unbootable machine fresh from distribution media (all data was lost). I'd like to avoid that here. I have not yet responded to the dialogs, and want to make sure the system is still bootable and not lose my data this time.

    Read the article

  • realtek lan driver problem - win 7

    - by tango _123
    Hi, my new notebook (ACER TM 8371) with Win 7(x32) professional as OS, has strage behaviour with respect to LAN. when I plug or unplug my charger cable, or my notebook goes in stad-by, or just a do nothing, the netwrok connection is lost. All the energy savings functionbality have been in-activated. if i check the network adapter information, it says "a network cabel is unplugged or corrupted", but it is not true.....the cable is in and it is not corrupted (i tried several which works on other machines). if a tried to di-habilitate and hence re-habilitate, it allows di-habilitation and not to further re-habilitate (it says "no driver for the network card" are available). in some cases, also, the driver disappears (i cannot see it anylonger). if i restart the notebook, everything comes back to normality, but.....today in 3 hours i had to restart 6 times!!! can anyone help me? win 7 says the driver is the last one, so no need to update it. here are some techinical information aboiut network card and driver: Name [00000015] Realtek PCIe GBE Family Controller Adapter type Ethernet 802.3 Product type Realtek PCIe GBE Family Controller Installated YES ID device PNP PCI\VEN_10EC&DEV_8168&SUBSYS_02831025&REV_02\4&266E4C4F&0&00E2 last reset 20/11/2009 11:27 Index 15 Service name RTL8167 I/O Port 0x0000FF00-0x0000FFFF Memory address 0xE2500000-0xE2500FFF Memory address 0xE1400000-0xE140FFFF IRQ Channel IRQ 18 Driver c:\windows\system32\drivers\rt86win7.sys (7.3.522.2009, 164,00 KB (167.936 Byte), 28/08/2009 22:12)

    Read the article

  • Server side url scanner for malware, spyware , viruses and protect my visitors

    - by Vangel
    I have a forum/groups site that contains a lot of external URLs, sometimes direct download links. I want to protect my visitors from possible attacks from malware sites as they are mot likely to click on these links. CUrrently I implement DBL (spamhaus) but thats not enough. I want to run a background task to check the outgoing links first. I have looked at similar questions in StackOverflow (wrongly posted there) and here but fail to find a question same as mine or a good answer. People have suggested ClamAV , I don't believe it can detect Web hosted malware sites and its has a lot of missed detection. I have looked at google safe browsing service ( http://code.google.com/apis/safebrowsing/developers_guide_v2.html very complicated to implement or maintain plus midway I get lost :S ) I can go for commercial solution, anything to protect the visitors and my site brand. But I would like to hear the opinion of server admins and if anyone has implemented such a service. My Server is basic CentOS LAMP stack. thank you very much in advance.

    Read the article

  • Why Would one VLAN have no Communication on one Switch?

    - by Webs
    So the problem is we have a device or host that needs to communicate on a specific VLAN. This VLAN is not new, it is running all throughout our environment and works fine. But the VLAN was recently configured on the switch in question, a Cisco 3750. The DHCP server is handing out addresses on that VLAN with no problem. I have verified the cable between the host and switch and tried multiple hosts, but none of them can communicate or get an address. I plugged my laptop into an empty port which had a different VLAN assigned and immediately got a DHCP address. When I changed that port to the same VLAN I'm having issues with I got the same problem. The laptop just sits there and tries to DHCP an address but nothing happens. I double checked the cores and their Layer 3 VLAN config and its fine too. Plus I figured the issue couldn't be with them because the VLAN works fine everywhere else it exists. So the only other thing I can think of is the switch, but the VLAN exists on the switch and seems to be configured correctly. The trunks appear to be configured just fine as well too. Anyone have any ideas? I'm lost on this one.

    Read the article

  • KVM Guest Reboot Loop

    - by javano
    I have been pulled into a situation where a KVM server (CentOS 6.2) lost power and upon reboot one of the guests hasn't started up again (XP SP3). I have SSH'ed in and someone must have changed something relating to the hyper visors prior to the power loss, but not rebooted all the guests. This particular guest wouldn't start because it was configured to use /usr/bin/qemu-system-x86_64 which isn't there now (assuming it was before?). I changed it to use /usr/libexec/qemu-kvm as this is what all the other guests on this server seem to be using, and its booting up. Using virt-manager on my local machine I can connect to the display of the XP machine and it gets as far as this screen; http://support.gateway.com/emachines/issues/2-1131285152-01.gif The problem I face now, is that which ever option I choose the machine just reboots. So it's and endless loop. I thought that perhaps a file system error maybe present due to the unclean shutdown. There is an XP SP3 ISO mounted under the guest, which I booted from in an attempt to access the recovery tools, but I don't have the Administrator password! I am out of ideas, and it's turning out to be quite the conundrum. Should I use a 3rd party live CD to test the FS for errors? How else can I trouble shoot these restarts?

    Read the article

  • Recover data from quick formatted DVD-R

    - by Andrii Kalytiiuk
    I need to recover data from quick-formatted DVD-R. Please advise a free of charge option (cheap commercial tools will be ok either). Disk was partially recorded with Windows built in disk recorder and recording most likely was not complete. Afterwards I have inserted partially recorded DVD again and on Windows recorder's message box 'How to use this disk?' selected - 'use for CD/DVD player' and data was completely lost - as new recording session was started. Files of photos were recorded on disk. What I have tried so far: DiskInternals CD-DVD recovery - sees 5 jpg files but can't show preview. Tool is commercial - trial version does not allow to recover files. CDCheck - doesn't see any files and reports errors at attempt to scand DVD CD Recovery Toolbox Free - does not even recognize DVD drive ISO Buster - recognizes two files - one MP3 file for 99% of recorded size and one ARC file for about 100 KB MiniTool Power Data Recovery - Free Edition - does not see any files on DVD Stellar Phoenix CD DVD Data Recovery - does not see any files BinaryBiz Virtual Lab - sees DVD disk but needs license to browse content Please advise how is it possible to recover files from DVD.

    Read the article

  • Almost All Xenserver Logical Volumes Disappeared - Recovery?

    - by Alex
    We had a hard disc crash of one of two hard discs in a software raid with a LVM on top. The server is running Citrix xenserver. On the hard disk which is still intact, the volume group gets detected well, but only one LV is left. (some hashes replaced by "x") # lvdisplay --- Logical volume --- LV Name /dev/VG_XenStorage-x-x-x-x-408b91acdcae/MGT VG Name VG_XenStorage-x-x-x-x-408b91acdcae LV UUID x-x-x-x-x-x-vQmZ6C LV Write Access read/write LV Status available # open 0 LV Size 4.00 MiB Current LE 1 Segments 1 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 253:0 root@rescue ~ # vgdisplay --- Volume group --- VG Name VG_XenStorage-x-x-x-x-408b91acdcae System ID Format lvm2 Metadata Areas 1 Metadata Sequence No 4 VG Access read/write VG Status resizable MAX LV 0 Cur LV 1 Open LV 0 Max PV 0 Cur PV 1 Act PV 1 VG Size 698.62 GiB PE Size 4.00 MiB Total PE 178848 Alloc PE / Size 1 / 4.00 MiB Free PE / Size 178847 / 698.62 GiB VG UUID x-x-x-x-x-x-53w0kL I could understand if a full physical volume is lost - but why only the logical volumes? Is there any explanation for this? Is there any way to recover the logical volumes? EDIT We are here in a rescue system. The problem is that the whole server does not boot (GRUB error 22) What we are trying to do is to access the root filesystem. But everything was in the LVM. We have only this: (parted) print Model: ATA SAMSUNG HD753LJ (scsi) Disk /dev/sdb: 750GB Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 32.3kB 750GB 750GB primary boot, lvm And this 750GB LVM volume is exactly what we see on top. edit2 Output of vgcfgrestore, but from the rescue system, as there is no root to chroot to. # vgcfgrestore --list VG_XenStorage-x-b4b0-x-x-408b91acdcae File: /etc/lvm/archive/VG_XenStorage-x-x-x-x-408b91acdcae_00000.vg VG name: VG_XenStorage-x-x-x-x-408b91acdcae Description: Created *before* executing '/sbin/vgscan --ignorelockingfailure --mknodes' Backup Time: Fri Jun 28 23:53:20 2013 File: /etc/lvm/backup/VG_XenStorage-x-x-x-x-408b91acdcae VG name: VG_XenStorage-x-x-x-x-408b91acdcae Description: Created *after* executing '/sbin/vgscan --ignorelockingfailure --mknodes' Backup Time: Fri Jun 28 23:53:20 2013

    Read the article

  • iTunes copy just metadata (song and album ratings, playlists) from iPod

    - by Jared Updike
    I have an iPod touch that I synched with my Windows computer (iTunes 9.0 I think) until my harddrive failed and I lost my entire library. I rebuilt the library (songs) from a year old backup (and various other source for songs) but my playlists and ratings are of course a year old. My iPod itself has most of the playlists and ratings I care most about (favorite songs and albums, rated 4 and 5, for example). I have a catch 22 situation where I feel nervous that I haven't backed up my iPod in around 4 months (when my drive failed) so I'd like to back it up as soon as possible... but if I back it up I have to clear all the songs and playlists and copy them back, which I can't really do since I need to rebuild my playlists on my computer first (using the data only available on my iPod!) The question: is there a better way to READ the information off my iPod than doing it manually, song by song and album by album and playlist by playlist (XML, text dump, database, spreadsheet, anything). In other words, mostly I want the information (metadata like ratings and playlists, not songs) copied off the iPod so I can more quickly get my iTunes library ratings and playlists re-built (manually) so I can finally wipe the music and back up my apps, etc. Then I'd like to copy the music back immediately. The part I'd like to avoid is manually navigating everything on my iPod to read through all the playlists and ratings (50 GB, 6,000+ songs) as I re-enter all of that data by hand. I've done a few dozen albums and it's pretty time consuming having to tap around on the iPod. Reading from a spreadsheet (for example, or XML which I could write a script to get into spreadsheet form) would probably help tremendously, plus then I'd have a backup of that information somewhere besides just my iPod.

    Read the article

  • I need a driver for my Cardbus USB 2.0 card

    - by Carl
    The picture and details of the card are here: http://www.ht-link.com/en/ProductView.asp?ID=106 The Windows drivers for this don't work right. I tried them on my previous laptop, and then installed the ones off their included CD. (Note that the systems requirements includes a CD-ROM drive...) I have a new laptop, and lost the CD. The website that lists the drivers is broken - the download links don't work. It is here: http://www.ht-link.com/en/DownView.asp?ID=10 I need the very first link - The Win XP drivers for the HT-112NEC. The company does not reply to my e-mails. I've tried searching Google for other sources for the driver (I didn't bother with those sites that want me to install driver detection software or create a log-in for their site). [Here's the problem I am getting using the drivers Windows XP SP3 installs: When I plug in my USB 2.0 hard-disk adapter, a USB Mass Storage Device entry is added in the Device Manager, but there is no entry under Disk Drives, and a drive letter is not assigned, so I can't access the driver. Like I said, this card didn't work without their special drivers on my other laptop, either.]

    Read the article

  • How do I recover drivers from other hard disk

    - by Carl
    The drivers for a Cardbus (PCMCIA) card that gives me 2 USB 2.0 ports are on the hard disk from my old laptop. I have lost the driver CD. I have a way to get files from that other hard disk. Which files do I need? The drivers for the card used to be on the following website - the information is still there, except the download links don't work: http://www.ht-link.com/en/DownView.asp?ID=10 - The drivers I need are the first listing - The Win XP drivers for the HT-112NEC. My e-mails to them have not been answered. The information on this card is here http://www.ht-link.com/en/ProductView.asp?ID=106 I already tried connecting that other drive to my new laptop (via USB) and adding the drive to the search criteria when selecting update driver in the Device Manager. It says there isn't a better match, and if I select manual the matching device is not listed. (I don't think "manual" sees drivers on the external hard disk - but only ones on the main drive and/or found listed in the registry.) I would try 'have disk' if I knew exactly what file to point to on the external drive. The drivers are on that hard disk - I installed them there, and used that card on that computer. The new laptop has Windows XP Pro SP3, the old one had Pro SP2 Thanks for any help.

    Read the article

  • Windows 7: Wi-Fi connection drops intermittently - only returns after "Troubleshoot connection" resets the adapter

    - by sleske
    On our laptop (running Windows 7) the Wi-Fi connection drops intermittently. Symptoms: Connectivity is suddenly lost, and the "signal strenght" indicator in the tray shows zero strength and a yellow "star" symbol. What happens then: The problem does not resolve itself by just waiting. If I click on the tray icon, the "Windows network diagnostics" wizard pops up and tells me that there is a networking problem (duh). If I click on the "repair" button (not sure about the wording), the wizard works for a while, then reports that it has reset the network adapter. Then Wi-Fi works again. While the above procedure has worked every time so far, it is very annoying. It takes 10-20s to repair the connection, and in the meantime downloads, video streams etc. may have been aborted. Some more details: The problem occurs without any apparent regularity, but usually a few minutes after powerup (though not every time). It happens frequently enough to be annoying. It is unlikely to be a router problem - another laptop running at the same time usually has no Wi-Fi problems. I am at a loss about what to try to troubleshoot this. Any ideas? Computer: Acer Aspire 7739Z. Wi-Fi card: Atheros AR5B125

    Read the article

  • hyper-v cluster behavior when losing network connectivity

    - by ChristopheD
    Setup: (rather new) Hyper-V R2 cluster with 2 nodes (in failover configuration). Fysical host OS: Windows Server 2008. About eight VM's (mixed: Windows Server 2008 and Linux) Yesterday we had a power outage of about 15 minutes. Our blades are on UPS so the fysical host machines (Windows Server 2008) never went down. Our main switches are not on UPS (yet) and we saw the behaviour similar to the following (as distilled from the event logs). The nodes in the cluster lost means of communication (because the external switches went down). The cluster wants to bring down one (the first) of the nodes (to start failover?). The previous step impacts clustered storage where the virtual machine VHD's are located. All VM's got brutally terminated and were found in a failed state in the failover manager in the host OS'es. The Linux VM's were kernel panicking and looked like they had their disk ripped out. This whole setup is rather new to us, so we are still learning about this. The question: We are putting switches on UPS soon but were wondering if the above is expected behavior (seems rather fragile) or if there are obvious improvements configuration-wise to handle such scenario's ? I can upload an evtx file concerning what exactly was going on in case that's necessary.

    Read the article

  • USB drive was bootable, but no longer boots

    - by i-g
    I'm trying to install a new OS onto a computer from a bootable USB stick. I previously installed Ubuntu Linux and it was a piece of cake -- I downloaded the ISO image, used UNetbootin to copy it to the USB drive and make it bootable, and that was that. Now, however, no matter what I try, I can't make the same USB drive bootable again! I've tried formatting it as FAT32 and NTFS. I've tried several different Linux distributions and Windows 7. I've tried using UNetbootin, Windows 7 USB Download Tool, WinToFlash, and manually making it bootable with diskpart/bootsect/bootrec. (Yes, I've tried bootsect /nt60 x: /force.) None of this seems to be working! When I try to boot from the drive, the machine reads from it (I can see the drive's LED blinking) and then gives me the same "Insert system disk and press Enter" message. (I've disabled booting from the hard drive.) Am I missing something I need to do to make the USB drive bootable again? I think it lost some pixie dust when I formatted it with the standard Windows formatting tool (it was quicker than deleting files), but I have no idea what it was or how to get it back. The USB drive in question is a SanDisk Cruzer 8GB SDCZ6. The computer I'm working on is running Windows Vista SP1.

    Read the article

  • Windows service fails to start with local user until password is entered again in logon tab

    - by Nick
    Basically we have a service where we use a local account as its logon. it has all the proper permissions, and everything is working fine, service starts and runs and all is good. Then one day, after rebooting, the service fails to start. Logs show incorrect password. Our technicians resolve the issue by simply retyping the password into the "Log On" tab from the services.msc. Unfortunately we have not been able to root cause. I suspect that the password that is stored for the service is lost somehow. Does anyone know where the password hash might be stored so we can check it? The only activities that seem to be possibly related are patching with Microsoft security patches, but we have multiple servers running the same service, and we have never seen more than one at a time, and its usually a different one each time when this occurrs. I believe this to be the same issue as this: Windows service fails to start with custom user until started once with local user But i was unable to add comments, and its really old.

    Read the article

  • How to setup RAID 1 with Intel RST on an existing Windows 7 system?

    - by instcode
    I'd like to setup RAID-1 using Intel Rapid Storage Technology on my Windows 7 64-bit system. I have an 1TB SATA HDD with Windows 7 system installed on the first primary partition (leftmost, ~200GB). The rest of this HDD is unallocated (~800GB). I bought another 2TB SATA, then created a primary partition (leftmost, ~500GB) and filled my data in. The rest of this HDD is unallocated (~1.5TB). A quick disk layout (XXX is the unallocated region): HDD1 (1TB): [ 200GB C:\ SYSTEM | XXXXXXXXXXXX ] HDD2 (2TB): [ 500GB Z:\ PROGRAM | XXXXXXXXXXXXXXXXXXXXXX ] Now, I want to create a 500GB RAID-1 partition (I'm not sure if using "partition" is correct here) on the rightmost of the 2 HDDs above without losing any existing data from both disks. Here is the expected layout: HDD1 (1TB): [ 200GB C:\ SYSTEM | XXXXXX | 500GB D:\ DATA - RAID-1 ] HDD2 (2TB): [ 500GB Z:\ PROGRAM | XXXXXXXXXXXXXXXX | 500GB D:\ DATA RAID-1] Let's not concern about data lost, is it possible to have that final layout using Intel RST? Previously, I tried this layout using dynamic disk & software RAID from Windows and it worked as expected, however, it's quite ugly in resynching after an OS failure that I don't want. If yes, is there a way to keep the data on existing partitions untouched or, at least, it should keep the SYSTEM partition safe (I'm okay if the PROGRAM partition has to be gone.)? Well, are there any strict/special steps I should follow when using the Intel RST manager in order to achieve that? If none of those questions above are "Yes", could you please suggest some other possible layouts that leave the C:SYSTEM partition untouched?

    Read the article

  • sql server 2005 instance unresponsive and all db's are 'in recovery'

    - by user44650
    we've got a sql server 2005 instance that one of our guys messed up, i believe they killed the sql server service and restarted the computer, and when it came back all of our databases are "in recovery" and it times out every time we try to connect to it. it's been 'in recovery'and unable to connect to 'msbd' (also in recovery) whenever we try to use SSMC, for the last 4 days now. i'm unsure how to use the DBCC CHECKDB command to check the db integrity. we have backups(which we can't recover from because it keeps timing out), and it's a testing server, so nothing in production is really lost. is there any way to get it out of recovery mode? we have another sqlserver instance running that's just fine, but this instance keeps timing out. the errors i keep seeing are database msdb is being recovered. wait until recovery is finished and an exception occurred while executing a transact-sql statement or batch Timeout expired. any thoughts? we don't really have a DBA here, or anyone with much sql experience.

    Read the article