Search Results

Search found 4258 results on 171 pages for 'maximum degree of paralle'.

Page 123/171 | < Previous Page | 119 120 121 122 123 124 125 126 127 128 129 130  | Next Page >

  • Is timeout in tracertoutput an indication of an error?

    - by nitramk
    TCP/IP packages sent from my computer to a remote server does not always reach destination and ends up being retransmitted sometimes several times before they succeed. To troubleshoot this, I'm running a tracert to the server: Tracing route to <site> [<address>] Over a maximum of 30 hops: 1 <1 ms <1 ms <1 ms mymachine 2 <1 ms <1 ms <1 ms gw.levonline.com [217.70.32.30] 3 <1 ms <1 ms <1 ms 81.201.213.218 4 <1 ms <1 ms <1 ms bmf1-hmf1.driften.net [81.201.213.12] 5 <1 ms <1 ms <1 ms 10ge-2-4-cr2.a1.sth.ownit.se [84.246.88.157] 6 <1 ms * <1 ms netnod-ix-ge-b-sth-4470.microsoft.com [195.69.11.181] 7 26 ms * * ge-3-0-0-0.ams-64cb-1a.ntwk.msn.net [207.46.42.1] 8 48 ms 57 ms 56 ms ten9-1.lts-76e-1.ntwk.msn.net [207.46.42.133] 9 * * * Request timed out. In step 6 and 7, I'm seeing timeouts while waiting for the reply from the server (as seen above). Running the same tracert many times gives varying output, sometimes the response is fine, but sometimes I get this timeout 1, 2 and sometimes for all 3 packets. The timeout always starts at the same server, netnod-ix-ge-b-sth-4470.microsoft.com. I've tried setting the tracert timeout to 10 seconds, but am still getting the timeout. Running tracert towards other servers does not give me the same timeout. Microsoft network technicians tells me that the problem is not on "their" side. Are these timeouts an indicator of a lost packet on the specific node which did not respond? Are the timeouts an indication of there being a problem, or is it normal?

    Read the article

  • How to interpret iozone values

    - by Henno
    I ran a test to measure my I/O IOPS on Linux: iozone -s 4g -r 2k -r 4k -r 8k -r 16k -r 32k -O -b /tmp/results.xls iozone claims that output is in operations per second yet the numbers are too big for that to be plausible. I'm observing some 320 CMDs/s maximum on vmware esx console (esxtop, then v). File size set to 4194304 KB Record Size 2 KB Record Size 4 KB Record Size 8 KB Record Size 16 KB Record Size 32 KB OPS Mode. Output is in operations per second. Command line used: iozone -s 4g -r 2k -r 4k -r 8k -r 16k -r 32k -O -b tmpresults.xls Time Resolution = 0.000001 seconds. Processor cache size set to 1024 Kbytes. Processor cache line size set to 32 bytes. File stride size set to 17 * record size. random random bkwd record stride KB reclen write rewrite read reread read write read rewrite read fwrite frewrite fread freread 4194304 2 19025 5580 27581 29848 284 198 415 1103217 1498 18541 4340 24245 25618 4194304 4 15650 21942 18962 21068 252 1198 193 976164 1677 22802 23093 21089 21232 4194304 8 11121 11638 10273 10165 247 1196 202 625020^C The test ran for 15 hours before I pressed ^C. Is that ordinary expectation for such command line (dedicated 4 drive RAID10 LUN, 10k RPM SAS drives in EMC CX300)?

    Read the article

  • Apache error "child pid XXXX exit signal exceeded file size limit (25)"

    - by Stephen Melrose
    Morning all, Apache on our internal development server stopped working last night. It's running, but all we get is a blank screen, no server errors. Examing the error log shows the following, [Fri Apr 23 09:13:57 2010] [notice] child pid XXXX exit signal exceeded file size limit (25) [Fri Apr 23 09:14:03 2010] [notice] child pid XXXX exit signal exceeded file size limit (25) [Fri Apr 23 09:14:03 2010] [notice] child pid XXXX exit signal exceeded file size limit (25) [Fri Apr 23 09:14:06 2010] [notice] child pid XXXX exit signal exceeded file size limit (25) After some Googling, we found that this is due to Apache trying to handle a file greater than it's maximum allowed limit, which by default is 2GB and is usually an error log. I did a search using find . -size +1000000k -ls (find all files greater than 1GB) in our log and web folders, but nothing showed up. I've also restarted Apache and rebooted the server itself serveral times. I've completely wiped the log folder and started a fresh. Nothing is working. Any ideas as to what else might be causing this? Thank you

    Read the article

  • ssl port didnt work on nginx

    - by Jin Lin
    I set up the unicorn and nginx on one of my ec2 machine. and my request are loading ok with nginx listen to port 80. but when I enable it to ssl, which listen to port 443. It doesn't work. and it can still work with port 80, https. server { listen 443 ssl; # replace with your domain name server_name domain.com; # replace this with your static Sinatra app files, root + public root /home/ubuntu/domain/public; ssl on; ssl_certificate /etc/ssl/domain.crt; ssl_certificate_key /etc/ssl/domain.key; # maximum accepted body size of client request client_max_body_size 4G; # the server will close connections after this time keepalive_timeout 5; location ~ ^/assets/ { add_header ETag ""; gzip_static on; expires max; add_header Cache-Control public; } location / { proxy_set_header X-Forwarded-Proto https; try_files $uri @app; } location @app { proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header Host $http_host; proxy_redirect off; # pass to the upstream unicorn server mentioned above proxy_pass http://unicorn_server; } }

    Read the article

  • Removing resource limits on Solaris 10

    - by mikeydonkey
    How should one remove all potential artificial resource limitations for a process? I just saw a case where a server application consumed resources so that some limitation was hit. The other shells into the same server etc were all extremely slow (waiting for something to free up for them; ie. prstat starting 5 minutes). It wasn't CPU/memory related problem so I think it has got something to do with ulimits / projects. Already managed to set the maximum open files to 500 000 and it helped a little bit. However there is something else and I can not figure out what resource is maxed out. I can get some in-house administrator probably to check this but I would like to understand how I could make sure there shouldn't be any limitations! If you think I am going the wrong way (would be better to figure out what limitation should be specfically tuned etc) please feel free to point me to the correct way. I know technical stuff - it's just Solaris 10 that is giving me headache :/

    Read the article

  • VMWare Raw Device Mapping Not Working

    - by George H. Lenzer
    While I'm waiting for VMWare support to get back to me, I thought I'd ask here. I have a 400 gig LUN presented from a fiber channel SAN to my VMWare host. It's legacy from another virtualization platform and I need to keep it as is to avoid a long period of downtime. I formatted my VMFS3 datastore with 4 meg blocks to allow up to 1 TB disks. Then I tried adding my 400 gig disk as a raw device in physical compatibility mode. I get the error: "File is larger than the maximum size supported by datastore 'Base Test'. [Base Test]VMTEST01/VMTEST01_2.vmdk Originally I had the VMFS datastore formatted with 1 meg blocks which was the cause of this problem since the largest disk allowed would be 256 gigs. But I deleted the data store and then reformatted with 4 megs blocks. I've also tried using virtual compatibility mode for the raw device but it still fails. Does anyone have any suggestions? I've been waiting for a little over a week for VMWare, but that's fine because I'm not yet a paying customer. I'm still in the eval phase.

    Read the article

  • Attending a Career Fair: &ldquo;Don&rsquo;t be shy &ndash; Be prepared&rdquo;

    - by jessica.ebbelaar
    There are a large number of ways to interact with companies nowadays. The career fair is a very effective and personal way to interact with a number of different companies in a very short period of time. Here are some simple tips to help you perform during a career fair. Do research The key to being successful at a career fair is to do research before you go. Make a first selection of the companies you feel could be interesting for you. Include many types of employers. Once you have decided on the list of companies you want to visit, go to their career portal. Inform yourself about what the company does, i.e what roles there are available, how the company culture is described, what impression the testimonials give you. The question that you still have after reviewing this information, are the ones you can discuss with the company on the fair. Sell yourself Visit the companies you have on your top 5 list first, so you will be at your highest energy level to make that first impression. Think in advance about what you are going to tell the recruiter. Prepare a 30-second introduction (including degree, strengths, skills & experience) Be confident when you talk about your experience. Remember to start the conversation with a smile, make good eye contact and give a firm handshake. You could be speaking to your next manager, so be professional! If you already know what jobs you are interested in, relate your skills and experience to the roles that the company has available. If you are not yet sure gather as much information as you can about employment and/or hiring procedures, specific skills necessary for different jobs, training and career paths. Stand out As career fairs are very crowded and the attending companies meet with a lot of potential candidates on one day, you have to make sure you are noticed in a positive way. A good preparation and asking questions that show you have a good understanding of the industry, organization and roles will help you. Be aware of time demands on employers. Do not monopolize an employer's time. Dress appropriately to make a good first impression. Bring your resume Do not forget to bring your resume in print or on a USB-stick to the fair. If you are searching for different types of jobs, bring different versions of your resume. Your resume should be short and professional on white paper that is free of graphics or fancy print styles and containing larger margins for interviewer notes. Follow up After each conversation ask who you can contact for follow-up discussions about the specific roles. Use the back of a business card to record notes that help you remember important details and follow-up instructions. If no card is available, record the contact information and your comments in your notepad or phone. Last but not least, thank everyone you talk to for their time. Follow up as soon as possible with thank you notes that address the companies’ hiring needs, your qualifications, and express your desire for a second interview. What not to do… Do not visit a company with a group of friends. Interact with the companies on your own, to make your own positive impression. Do not walk up to a recruiter and interrupt a current conversation; wait your turn and be polite. What you should absolutely avoid is a grab and run on freebies! Take the time to speak to the company and ask for a freebie at the end of the conversation in case they are not offered to you. Good luck with the preparations for the career fair you will attend. Oracle recruiters look forward to meet you! They will be present on a large number of fairs in the region. For an overview of the fairs go to the Events & Calendar page on http://campus.oracle.com If you have any questions related to this article feel free to contact [email protected].

    Read the article

  • Private IP getting routed over Internet

    - by WernerCD
    We are setting up an internal program, on an internal server that uses the private 172.30.x.x subnet... when we ping the address 172.30.138.2, it routes across the internet: C:\>tracert 172.30.138.2 Tracing route to 172.30.138.2 over a maximum of 30 hops 1 6 ms 1 ms 1 ms xxxx.xxxxxxxxxxxxxxx.org [192.168.28.1] 2 * * * Request timed out. 3 12 ms 13 ms 9 ms xxxxxxxxxxx.xxxxxx.xx.xxx.xxxxxxx.net [68.85.xx.xx] 4 15 ms 11 ms 55 ms te-7-3-ar01.salisbury.md.bad.comcast.net [68.87.xx.xx] 5 13 ms 14 ms 18 ms xe-11-0-3-0-ar04.capitolhghts.md.bad.comcast.net [68.85.xx.xx] 6 19 ms 18 ms 14 ms te-1-0-0-4-cr01.denver.co.ibone.comcast.net [68.86.xx.xx] 7 28 ms 30 ms 30 ms pos-4-12-0-0-cr01.atlanta.ga.ibone.comcast.net [68.86.xx.xx] 8 30 ms 43 ms 30 ms 68.86.xx.xx 9 30 ms 29 ms 31 ms 172.30.138.2 Trace complete. This has a number of us confused. If we had a VPN setup, it wouldn't show up as being routed across the internet. If it hit an internet server, Private IP's (such as 192.168) shouldn't get routed. What would let a private IP address get routed across servers? would the fact that it's all comcast mean that they have their routers setup wrong?

    Read the article

  • Windows 7 mapped drive kicking off OS X users

    - by Collin White
    I've mapped a network drive on my Windows 7 PC at my office. The windows machine has a few TB of storage that is being accessed by my development team (all running mac os 10.7). The share seems to work fine for a little while but will timeout and kick the mac users off and sometimes disallows a connection on the next attempt. Restarting the windows machine fixes the problem. I've tried this tutorial as well as setting the maximum session length in the Local Security Policy section to 99999 (I discovered 0 did not mean unlimited, only a 'reasonable ammount of time') anyway, the setting is now for ~208 days which is sufficient (see attached). I'm having trouble debugging this in general so if anyone has some pointers I'm all ears. This is a intermittent issue which in my opinion are the hardest kinds to debug. If anyone knows of how I might monitor connections from the PC that would also be pretty cool. Previously the files were hosted on a mac mini and everything was working just fine (the mini just didn't have the ability for the storage capacity we needed) so I believe it is some windows setting that is kicking users off. Anyway, thanks for reading.

    Read the article

  • Motion - takes snapshot without motion detected

    - by Emmanuel Brunet
    I've been installed the standard motion 3.2.12 package on debian 7.5. I would like to get snapshot ONLY when motion is detected, but it still saves a picture every second without any activity in front of the camera. I'm using a TENVIS JPT3815W IP camera motion.conf here is my configuration file setup_mode off target_dir /media/videos/log/webcam netcam_url http://webcam/snapshot.cgi netcam_tolerant_check on netcam_userpass admin:alpha1237 # Output frames at 1 fps when no motion is detected and increase to the # rate given by webcam_maxrate when motion is detected (default: off) webcam_motion off output_all off # detection settings 1-255 default 32 noise_level 50 # Maximum framerate for webcam streams (default: 1) webcam_maxrate 25 pre_capture 0 framerate 25 gap 30 locate on mail [email protected] text_right "FRONT CAMERA %Y/%m/%d - %T" text_double on ffmpeg_cap_new on ffmpeg_cap_motion on ffmpeg_video_codec mpeg4 output_motion off snapshot_interval 0 # Quality of the jpeg (in percent) images produced (default: 50) quality 90 # Restrict webcam connections to localhost only (default: on) webcam_localhost off # Limits the number of images per connection (default: 0 = unlimited) # Number can be defined by multiplying actual webcam rate by desired number of seconds # Actual webcam rate is the smallest of the numbers framerate and webcam_maxrate webcam_limit 0 Issue when I start motion images are stored in /media/videos/log/webcam nearly every second. I hjust want to get images when a motion is detected and the according video clip Any idea where the configuration fails ?

    Read the article

  • Learn Many Languages

    - by Phil Factor
    Around twenty-five years ago, I was trying to solve the problem of recruiting suitable developers for a large business. I visited the local University (it was a Technical College then). My mission was to remind them that we were a large, local employer of technical people and to suggest that, as they were in the business of educating young people for a career in IT, we should work together. I anticipated a harmonious chat where we could suggest to them the idea of mentioning our name to some of their graduates. It didn’t go well. The academic staff displayed a degree of revulsion towards the whole topic of IT in the world of commerce that surprised me; tweed met charcoal-grey, trainers met black shoes. However, their antipathy to commerce was something we could have worked around, since few of their graduates were destined for a career as university lecturers. They asked me what sort of language skills we needed. I tried ducking the invidious task of naming computer languages, since I wanted recruits who were quick to adapt and learn, with a broad understanding of IT, including development methodologies, technologies, and data. However, they pressed the point and I ended up saying that we needed good working knowledge of C and BASIC, though FORTRAN and COBOL were, at the time, still useful. There was a ghastly silence. It was as if I’d recommended the beliefs and practices of the Bogomils of Bulgaria to a gathering of Cardinals. They stared at me severely, like owls, until the head of department broke the silence, informing me in clipped tones that they taught only Modula 2. Now, I wouldn’t blame you if at this point you hurriedly had to look up ‘Modula 2′ on Wikipedia. Based largely on Pascal, it was a specialist language for embedded systems, but I’ve never ever come across it in a commercial business application. Nevertheless, it was an excellent teaching language since it taught modules, scope control, multiprogramming and the advantages of encapsulating a set of related subprograms and data structures. As long as the course also taught how to transfer these skills to other, more useful languages, it was not necessarily a problem. I said as much, but they gleefully retorted that the biggest local employer, a defense contractor specializing in Radar and military technology, used nothing but Modula 2. “Why teach any other programming language when they will be using Modula 2 for all their working lives?” said a complacent lecturer. On hearing this, I made my excuses and left. There could be no meeting of minds. They were providing training in a specific computer language, not an education in IT. Twenty years later, I once more worked nearby and regularly passed the long-deserted ‘brownfield’ site of the erstwhile largest local employer; the end of the cold war had led to lean times for defense contractors. A digger was about to clear the rubble of the long demolished factory along with the accompanying growth of buddleia and thistles, in order to lay the infrastructure for ‘affordable housing’. Modula 2 was a distant memory. Either those employees had short working lives or they’d retrained in other languages. The University, by contrast, was thriving, but I wondered if their erstwhile graduates had ever cursed the narrow specialization of their training in IT, as they struggled with the unexpected variety of their subsequent careers.

    Read the article

  • Mysqld increases the load on the CPU and drops after flush-tables

    - by mirage
    Help please advice on the issue. Normal load on the cpu 20-30% us + sy. After restoring the database files from the slave server (same version) began a periodic problem. mysql starts to load the cpu at 100% (us + sy grows proportionally). The queue is growing, everything slows down. But with mysqladmin flush-tables are normalized for a few hours. Dedicated linux server running mysql 2 x E5506 24Gb RAM, database size 50Gb. [OK] Currently running supported MySQL version 5.0.51a-24 + lenny4-log [OK] Operating on 64-bit architecture -------- Storage Engine Statistics --------------------------------------- ---- [-] Status: + Archive-BDB-Federated + InnoDB-ISAM-NDBCluster [-] Data in MyISAM tables: 33G (Tables: 1474) [-] Data in InnoDB tables: 1G (Tables: 4) [-] Data in MEMORY tables: 120K (Tables: 3) [-] Reads / Writes: 91% / 9% [-] Total buffers: 12.8M per thread and 7.1G global [OK] Maximum possible memory usage: 15.8G (66% of installed RAM) 4000 - 5500 rps key_buffer = 1536M max_allowed_packet = 2M table_cache = 4096 sort_buffer_size = 409584 read_buffer_size = 128K read_rnd_buffer_size = 8M myisam_sort_buffer_size = 64M thread_cache_size = 500 query_cache_size = 100M thread_concurrency = 24 max_connections = 700 tmp_table_size = 4096M join_buffer_size = 4M max_heap_table_size = 4096M query_cache_limit = 1M low_priority_updates = 1 concurrent_insert = 2 wait_timeout = 30 server-id = 1 log_bin = /var/log/mysql/mysql-bin.log expire_logs_days = 10 max_binlog_size = 100M innodb_buffer_pool_size = 1536M innodb_log_buffer_size = 4M innodb_flush_log_at_trx_commit = 2 How to solve the problem?

    Read the article

  • Enabling JMX for proxool with tomcat

    - by dialt0ne
    I am trying to get proxool's MBeans available so that I can see/manipulate them with jconsole. I have jconsole working, but I don't see anything related to proxool. The system is using Sun Java 1.5.0_17 (I know, I know... I'm working with the developers to upgrade). JMX is enabled by modifying $JAVA_OPTS in my tomcat 5.5 startup script: SJO="$SJO -Dcom.sun.management.jmxremote" SJO="$SJO -Dcom.sun.management.jmxremote.port=4998" SJO="$SJO -Dcom.sun.management.jmxremote.authenticate=false" SJO="$SJO -Dcom.sun.management.jmxremote.ssl=false" JAVA_OPTS="$JAVA_OPTS $SJO" I have proxool configured with JNDI in server.xml: <GlobalNamingResources> <Resource name="jdbc/database" auth="Container" type="javax.sql.DataSource" factory="org.logicalcobwebs.proxool.ProxoolDataSource" user="username" password="password" proxool.driver-url="jdbc:oracle:thin:@fqdn.example.com:1521:MYSID" proxool.driver-class="oracle.jdbc.driver.OracleDriver" proxool.alias="mysid" proxool.maximum-connection-count="20" proxool.statistics="20s,5m,15m" proxool.statistics-log-level="INFO" proxool.jmx="true" proxool.verbose="true" /> </GlobalNamingResources> My test .jsp can run queries and I can see it using the connections with the proxool admin servlet, but I'm unsure if there's more I need to configure in tomcat or proxool to get JMX functioning. Advice? jmxproxy info edit: The jmxproxy servlet is working - when I go to the URL http://tomcatserver.example.com:4999/manager/jmxproxy/?qry=*:type%3DRequestProcessor,* the results are: OK - Number of results: 2 Name: Catalina:type=RequestProcessor,worker=http-8080,name=HttpRequest0 modelerType: org.apache.coyote.RequestInfo bytesSent: 0 requestBytesSent: 0 contentLength: -1 bytesReceived: 0 requestProcessingTime: 1297983483666 globalProcessor: org.apache.coyote.RequestGroupInfo@32dc51c8 requestBytesReceived: 0 serverPort: -1 stage: 0 requestCount: 0 maxTime: 0 processingTime: 0 errorCount: 0 Name: Catalina:type=RequestProcessor,worker=jk-127.0.0.1-8009,name=JkRequest794 modelerType: org.apache.coyote.RequestInfo virtualHost: tomcatserver.example.com bytesSent: 0 method: GET remoteAddr: 172.30.3.51 requestBytesSent: 0 contentLength: -1 workerThreadName: TP-Processor15 bytesReceived: 0 requestProcessingTime: 9 globalProcessor: org.apache.coyote.RequestGroupInfo@1e7d3b8e protocol: HTTP/1.1 currentQueryString: qry=*%3Atype%3DRequestProcessor%2C* requestBytesReceived: 0 serverPort: 4999 stage: 3 requestCount: 0 maxTime: 0 processingTime: 0 currentUri: /manager/jmxproxy/ errorCount: 0 And more to the point http://tomcatserver.example.com:4999/manager/jmxproxy/?qry=Catalina:type%3DEnvironment,resourcetype%3DGlobal,name%3DProxool yields: OK - Number of results: 0

    Read the article

  • Triple monitor setting in Linux with USB-HDMI adapter

    - by Oscar Carballal
    I'm trying to set up a triple monitor desktop at my office using Fedora 17, but it seems impossible, let me explain the setting: Laptop ASUS K53SD with 2 graphic cards, Intel and nVidia (Screen controled by Intel card) 24" Full HD monitor connected to the HDMI output (controlled by Intel card) 23" Full HD monitor connected to an USB-HDMI adapter (via framebuffer in /dev/fb2, apparently) VGA output (not used) controlled by nVidia card First of all, the USB-HDMI adapter works perfectly, it gives me a green screen (which means the communication is OK) and I can make it work if I set up a single monitor setting via framebuffer in Xorg. Here I leave the page where I got the instructions: http://plugable.com/2011/12/23/usb-graphics-and-linux Now I'm trying to set up the the two main monitors (laptop and 24") with the intel driver and the 23" with the framebuffer, but the most succesful configuration I get is the two main monitors working and the third disconnected. Do you have any idea what can I do to make this work? Here I leave my xRandr output and my Xorg conf: -> xrandr Screen 0: minimum 320 x 200, current 3286 x 1080, maximum 8192 x 8192 LVDS1 connected 1366x768+0+0 (normal left inverted right x axis y axis) 344mm x 193mm 1366x768 60.0*+ 1024x768 60.0 800x600 60.3 56.2 640x480 59.9 VGA2 disconnected (normal left inverted right x axis y axis) HDMI1 connected 1920x1080+1366+0 (normal left inverted right x axis y axis) 531mm x 299mm 1920x1080 60.0*+ 50.0 25.0 30.0 1680x1050 59.9 1680x945 60.0 1400x1050 74.9 59.9 1600x900 60.0 1280x1024 75.0 60.0 1440x900 75.0 59.9 1280x960 60.0 1366x768 60.0 1360x768 60.0 1280x800 74.9 59.9 1152x864 75.0 1280x768 74.9 60.0 1280x720 50.0 60.0 1440x576 25.0 1024x768 75.1 70.1 60.0 1440x480 30.0 1024x576 60.0 832x624 74.6 800x600 72.2 75.0 60.3 56.2 720x576 50.0 848x480 60.0 720x480 59.9 640x480 72.8 75.0 66.7 60.0 59.9 720x400 70.1 DP1 disconnected (normal left inverted right x axis y axis) 1920x1080_60.00 60.0 The Xorg file: # Xorg configuration file for using a tri-head display Section "ServerLayout" Identifier "Layout0" Screen 0 "HDMI" 0 0 Screen 1 "USB" RightOf "HDMI" Option "Xinerama" "on" EndSection ########### MONITORS ################ Section "Monitor" Identifier "USB1" VendorName "Unknown" ModelName "Acer 24as" Option "DPMS" EndSection Section "Monitor" Identifier "HDMI1" VendorName "Unknown" ModelName "Acer 23SH" Option "DPMS" EndSection ########### DEVICES ################## Section "Device" Identifier "Device 0" Driver "intel" BoardName "GeForce" BusID "PCI:0:02:0" Screen 0 EndSection Section "Device" Identifier "USB Device 0" driver "fbdev" Option "fbdev" "/dev/fb2" Option "ShadowFB" "off" EndSection ############## SCREENS ###################### Section "Screen" Identifier "HDMI" Device "Device 0" Monitor "HDMI1" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "USB" Device "USB Device 0" Monitor "USB1" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection

    Read the article

  • OpenGl / C++ and some strange light problem on half board

    - by mlodziaszka
    I have some problem with lights in my opengl "game". I have board with is square (-50,50), (50, 50), (50, -50), (-50,-50) x and z since y doesn't matter at all. I tried to make something like flashlight its moving and rotating with camera (me), but when i try to rotate more then 90 degree to left or right it just give diffrend light: http://imageshack.us/photo/my-images/688/lightij.jpg/ (left is spotlight, right point light) There is also a point light in the middle, but its working strange(not like a pointlight) it shines only on half of the board from (-50,50), (50, 50), (50, 0), (-50,-0) x and y: Link to my repo where u can find game exe in download and full code in source: https://bitbucket.org/mlodziaszka/my_game All more fragments of light: float gl_amb[] = { 0.2f, 0.2f, 0.2f, 1.0f }; glLightModelfv(GL_LIGHT_MODEL_AMBIENT, gl_amb); glEnable(GL_LIGHTING); // Wlaczenie oswietlenia glShadeModel(GL_SMOOTH); // Wybor techniki cieniowania glEnable(GL_LIGHT0); // Wlaczenie 0-go zrodla swiatla glEnable(GL_LIGHT1); Cubes parametri: float m1_amb[] = { 1.0f, 0.0f, 0.0f, 1.0f }; float m1_dif[] = { 1.0f, 0.0f, 0.0f, 1.0f }; float m1_spe[] = { 1.0f, 0.0f, 0.0f, 1.0f }; glMaterialfv(GL_FRONT, GL_AMBIENT, m1_amb); glMaterialfv(GL_FRONT, GL_DIFFUSE, m1_dif); glMaterialfv(GL_FRONT, GL_SPECULAR, m1_spe); glMaterialf(GL_FRONT, GL_SHININESS, 50.0f); Texture parametri: float m1_amb[] = { 1.0f, 1.0f, 1.0f, 1.0f }; float m1_dif[] = { 1.0f, 1.0f, 1.0f, 1.0f }; float m1_spe[] = { 1.0f, 1.0f, 1.0f, 1.0f }; glMaterialfv(GL_FRONT, GL_AMBIENT, m1_amb); glMaterialfv(GL_FRONT, GL_DIFFUSE, m1_dif); glMaterialfv(GL_FRONT, GL_SPECULAR, m1_spe); glMaterialf(GL_FRONT, GL_SHININESS, 0.0f); glTexEnvf( GL_TEXTURE_ENV, GL_TEXTURE_ENV_MODE, GL_MODULATE ); Light0: //with some magic sn't working anyway float l0_amb[] = { 0.2f, 0.2f, 0.2f, 1.0f }; float l0_dif[] = { 1.0f, 1.0f, 1.0f, 1.0f }; float l0_spe[] = { 1.0f, 1.0f, 1.0f, 1.0f }; float l0_pos[] = { g_Camera.m_vPosition.x, g_Camera.m_vPosition.y, g_Camera.m_vPosition.z, 1.0f }; float temp = 0.0f, temp2 = 0.0f, temp3 = 0.0f; if(g_Camera.m_vView.z < g_Camera.m_vPosition.z) { temp = g_Camera.m_vView.x - g_Camera.m_vPosition.x; temp2 = g_Camera.m_vView.z - g_Camera.m_vPosition.z; } else { temp = g_Camera.m_vView.x - g_Camera.m_vPosition.x; temp2 = g_Camera.m_vView.z - g_Camera.m_vPosition.z; } float l0_pos1[] = {temp, 0.0f, temp2}; //float l0_pos1[] = {-1.0f, 0.0f, -1.0f}; glLightfv(GL_LIGHT0, GL_AMBIENT, l0_amb); glLightfv(GL_LIGHT0, GL_DIFFUSE, l0_dif); glLightfv(GL_LIGHT0, GL_SPECULAR, l0_spe); glLightfv(GL_LIGHT0, GL_POSITION, l0_pos); glLightf (GL_LIGHT0, GL_SPOT_CUTOFF, 15.0f); glLightfv(GL_LIGHT0, GL_SPOT_DIRECTION, l0_pos1); Light1: float l1_amb[] = { 0.2f, 0.2f, 0.2f, 1.0f }; float l1_dif[] = { 1.0f, 1.0f, 1.0f, 1.0f }; float l1_spe[] = { 1.0f, 1.0f, 1.0f, 1.0f }; float l1_pos[] = { 0.0f, 0.0f, 0.0f, 1.0f }; glLightfv(GL_LIGHT1, GL_AMBIENT, l1_amb); glLightfv(GL_LIGHT1, GL_DIFFUSE, l1_dif); glLightfv(GL_LIGHT1, GL_SPECULAR, l1_spe); glLightfv(GL_LIGHT1, GL_POSITION, l1_pos); I know that way I made this very old, but for now i want to keep this like that. I wouldbe realy gratefull if someone can tell me what is wrong with my lights xD full code: link up ^^

    Read the article

  • Ext3 fs: Block bitmap for group 1 not in group (block 0). is fs dead?

    - by ip
    My company has a server with one big partition with Mysql database and php files. Now this partition seems to be corrupted, as reported from kernel messages when I tried to mount it manually: [329862.817837] EXT3-fs error (device loop1): ext3_check_descriptors: Block bitmap for group 1 not in group (block 0)! [329862.817846] EXT3-fs: group descriptors corrupted! I've tried to recovery it running tools from a PLD livecd. These are the tools I have tested: - e2retrieve - testdisk - photorec - dd_rescue/dd_rhelp - ddrescue - fsck.ext2 - e2salvage without any success. dumpe2fs 1.41.3 (12-Oct-2008) Filesystem volume name: /dev/sda3 Last mounted on: <not available> Filesystem UUID: dd51610b-6de0-4392-a6f3-67160dbc0343 Filesystem magic number: 0xEF53 Filesystem revision #: 1 (dynamic) Filesystem features: has_journal filetype sparse_super Default mount options: (none) Filesystem state: not clean with errors Errors behavior: Continue Filesystem OS type: Linux Inode count: 9502720 Block count: 18987570 Reserved block count: 949378 Free blocks: 11555345 Free inodes: 11858398 First block: 0 Block size: 4096 Fragment size: 4096 Blocks per group: 32768 Fragments per group: 32768 Inodes per group: 16384 Inode blocks per group: 512 Last mount time: Wed Mar 24 09:31:03 2010 Last write time: Mon Apr 12 11:46:32 2010 Mount count: 10 Maximum mount count: 30 Last checked: Thu Jan 1 01:00:00 1970 Check interval: 0 (<none>) Reserved blocks uid: 0 (user root) Reserved blocks gid: 0 (group root) First inode: 11 Inode size: 128 Journal inode: 8 Journal backup: inode blocks dumpe2fs: A block group is missing an inode table while reading journal inode e2fsck 1.41.3 (12-Oct-2008) fsck.ext3: Group descriptors look bad... trying backup blocks... fsck.ext3: A block group is missing an inode table while checking ext3 journal for /dev/sda3 I tried also backup superblocks, same error result. There's any other tools I have to test before considering these disk definitely unrecoverable? Many thanks, ip

    Read the article

  • Compaq motherboard CQ60 AMD - nvidia chipsed graphic problem

    - by Dritan
    Hi! It nice to have read that you solved this problem this way. I have 2 laptops Compaq CQ60 AMD Athlon with Nvidia graphic cards. the first one is new, when i press power button, it lights up only the ON led in front and nothing else, no fan working, blank screen, no beep.. I don't know what may be the problem. When I put on power adaptor, it lights up only the side power led near dhe power adapter plug but it doesn't light up the front led one. the second one have this problem that it spins the fan, light power and On led, but it doesn't show nothing on the screen blank (even with external monitor). In this case it maybe this problem of the Nvida Graphic Chip and it may need a reflow. I have an hot air station, but I don't know if I should try this or the oven one. Please can you give me any suggestion what to do to solve this. I have read that the solution of the Oven method is just temporary,maximum of three months, do you have the same experience about this? Any suggestion is wellcome.

    Read the article

  • Strange battery behavior on laptop

    - by EpsilonVector
    My laptop is behaving rather strangely lately, and I was hoping to get some idea as to what may be causing such symptoms. The problem: When charging, very minute or so it loses connectivity with the AC adapter for a split second, and regains it back immediately. When this happens the little light that indicates the computer is plugged in does flicker off and back on, but I checked the adapter by replacing the battery on my laptop, and this indeed solves the problem, so it is probably the battery which is at fault, not the adapter (I also tried to move the adapter's wire around just to make sure it had nothing to do with torn wires). I suppose that the obvious solution is to get a new battery, but as far as battery defects go- this is a rather strange one; it loses connection with the adapter, but still powers the computer, and changing the power setting to a balanced plan (was maximum performance) seem to have solved the problem too. Is there a chance this is not simply the battery, but some kind of other electronic defect? And if not, what can cause it to behave so strangely? PS I tried to recalibrate it- didn't help.

    Read the article

  • Vista Screen resolution Changes when Switching Users

    - by Benjol
    I regularly have a problem when switching between users in Vista - the screen resolution drops down to 800x600. If I try to set the resolution back to the maximum, it says nothing, but just keeps it at 800x600. I can set it back to an intermediate value. Otherwise I have to either restart the PC, or sometimes if I log off one of the users, I can then set the resolution back to max. Might it also have something to do with using sleep mode instead of performing regular shutdowns? I thought it might be related to the desktop background image taking up too much space, but even with plain colours, the problem still occurs. There is an enormous thread on this here, but not really any answers. From what I can gather from that thread, it isn't related to any particular applications, nor limited to a particular make of graphics card or monitor, so I don't think that including hardware details is useful. This is a very annoying problem, as it screws up my desktop and screen layout every single time. Has anyone here experienced this problem or found a solution? I've noticed that Windows Update has tried to install nVidia updates and apparently they've failed on several occasions. Not sure if that is of any relevance or not. UPDATE The last post on the thread: FWIW - I had this problem for about 2 years and wrote a number of posts in this thread in the past. It survived OS reinstallation, change of practically all of my hardware piece by piece (mobo, cpu, monitor, graphics card, memory, power supply...) I used to be affected by this annoying problem at least once every 24-48 hours. About 1.5 months ago I wiped out my 32 bit vista ultimate installation and installed Windows7 ultimate 64 bit from scratch and never saw this problem again. GOOD RIDDANCE. Vista was a pathetic piece of __ that felt like a flashback to the old [horrible] NT4/Windows95 days. I was seriously considering switching over to Apple/Mac OSX if this problem persisted.

    Read the article

  • Is this way of using Excel 2007 Pivot table for BI scalable ?

    - by Sim
    Hi all, Background: We need to consolidate sales data across the country to do analysis Our Internet connection/IT expertise/IT investment is not quite strong, therefore full BI solution is out of question I tried several SaaS BI solution (GoodData, ZohoReports) and while they're good, they seem not to fully support what we need We're looking at 'bout 2 millions record for every 2 months My current approach Our (10) sites currently gathers data from all their branches and consolidate them into 1 Excel file with Pivot table and embed source data In HQ, I will request 10 sites to send back those Excel files periodically We will import those Excel to our MSSQL server There will be a master Excel file, that will also have the same pivot table (as those came from site Excel file), and datasource is the MSSQL server More details For testing, I currently use MSSQL 2008 Express on my laptop So far, I imported our transactions for the past 2 months and there are 2 millions+ row in 1 table in MSSQL (we just use 1 table, corresponding to our common pivot table structure). DB size is ~ 600 MB In the master Excel file, if not including the source data, it's just < 10MB. Including the source data will increase the size to 60 MB (so I supposed Office 2007 automatically zip the data ?) I try using the Pivot (drag-and-drop fields) and the performance so far is OK (my laptop specs: C2D T7200, 3GB RAM, Windows XP) So my question is : If we're looking at full year transaction (roughly 15 millions rows in MSSQL 2008 Express, 3.6 GB in size), is there any issue with that 15 million rows in 1 table in SQL Express ? Is there any performance issue with the pivot table at that time ? Can it still embed the source data ? (I google-ed but didn't find the maximum size of source data Excel 2007 can embed) Any other suggestions on how we can better do this ? Given that we can't afford the full BI solution, any light-weight/budget/SaaS BI that you can recommend ? Thanks

    Read the article

  • FTP Server with advanced features

    - by Nikolas Sakic
    Hi, We supply zone-files to our customers. Some zone files are big about 300MB and some are quite small, maybe like 1MB. We had this issue that someone setup a script to continually download the file. Imagine downloading 300MB file a few hundred times a day. Since, we don't have packet-shaper to throttle the traffic, we need to upgrade ftp server and use add-on modules to limit the download somehow. We currently use proftpd server. Also note that there are different users for different domains - say, if you want to download zone file for .INFO domain, then you use a particular user. That user can't download any other zone's file. This is what we are looking for: Have maximum of 400MB download per user per day. Or even have different download limit for different users per day. Have one connection per user at any time. Max # of connection (non-simultaneous) per user per day is 5. Anyone trying to exceed that gets banned for 24 hours. Has anyone used FTP server with similar restrictions above? Does anyone have any ideas where I can start? Any help would be appreciated. Thanks. -N

    Read the article

  • SQLSTATE[HY000]: General error: 2006 MySQL server has gone away

    - by Barkat Ullah
    Server details: RAM: 16GB HDD: 1000GB OS: Linux 2.6.32-220.7.1.el6.x86_64 Processor: 6 Core Please see the link below for my # top preview: I can often see the error mentioned in title in my plesk panel and my /etc/my.cnf configuration are as below: bind-address=127.0.0.1 local-infile=0 datadir=/var/lib/mysql socket=/var/lib/mysql/mysql.sock user=mysql max_connections=20000 max_user_connections=20000 key_buffer_size=512M join_buffer_size=4M read_buffer_size=4M read_rnd_buffer_size=512M sort_buffer_size=8M wait_timeout=300 interactive_timeout=300 connect_timeout=300 tmp_table_size=8M thread_concurrency=12 concurrent_insert=2 query_cache_limit=64M query_cache_size=128M query_cache_type=2 transaction_alloc_block_size=8192 max_allowed_packet=512M [mysqldump] quick max_allowed_packet=512M [myisamchk] key_buffer_size=128M sort_buffer_size=128M read_buffer_size=32M write_buffer_size=32M [mysqlhotcopy] interactive-timeout [mysqld_safe] log-error=/var/log/mysqld.log pid-file=/var/run/mysqld/mysqld.pid open_files_limit=8192 As my server httpd conf is set to /etc/httpd/conf.d/swtune.conf and the configuration is as below: at prefork.c: <IfModule prefork.c> StartServers 8 MinSpareServers 10 MaxSpareServers 20 ServerLimit 1536 MaxClients 1536 MaxRequestsPerChild 4000 </IfModule> If I run grep -i maxclient /var/log/httpd/error_log then I can see everyday this error: [root@u16170254 ~]# grep -i maxclient /var/log/httpd/error_log [Sun Apr 15 07:26:03 2012] [error] server reached MaxClients setting, consider raising the MaxClients setting [Mon Apr 16 06:09:22 2012] [error] server reached MaxClients setting, consider raising the MaxClients setting I tried to explain everything that I changed to keep my server okay, but maximum time my server is down. Please help me which parameter can I change to keep my server okay and my sites can load fast. It is taking too much time to load my sites.

    Read the article

  • Too many concurrent connections Exchange 2010. What else is there to check?

    - by hydroparadise
    I thought that I had this under control before. But for some reason during our last email marketing promo, I start receiving from our mass email client (built in house).. The message could not be sent to the SMTP server. The transport error code is 0x800ccc67. The server repsonse was 421 4.3.2 The maximum number of concurrent connections has exceeded a limit, closing transmission channel again. There's several places I've checked to make sure that wouldn't be an issue. First I checked that receive connector was set to receive an adequate number of connections on our relay connector (1000 connections). Then, I would later find out about Throttling Policies. I created one and set all the properties I knew to set in terms of the policy following properties to 1000; EWSMaxConcurrency, OWAMaxConcurrency, CPAMaxConcurrency, and CPAMaxConcurrency. Still, the email client starts receiving the error shortly after 100 has been sent and takes about 15-30 seconds. The process is then repeatable, but still the error gets received at the same spot everytime. Is there a rate setting that I am missing? Was there a windows update that I missed looking at? Should the software have it's own throttling feature?

    Read the article

  • Keepalived for more than 20 virtual addresses

    - by cvaldemar
    I have set up keepalived on two Debian machines for high availability, but I've run into the maximum number of virtual IP's I can assign to my vrrp_instance. How would I go about configuring and failing over 20+ virtual IP's? This is the, very simple, setup: LB01: 10.200.85.1 LB02: 10.200.85.2 Virtual IPs: 10.200.85.100 - 10.200.85.200 Each machine is also running Apache (later Nginx) binding on the virtual IPs for SSL client certificate termination and proxying to backend webservers. The reason I need so many VIP's is the inability to use VirtualHost on HTTPS. This is my keepalived.conf: vrrp_script chk_apache2 { script "killall -0 apache2" interval 2 weight 2 } vrrp_instance VI_1 { interface eth0 state MASTER virtual_router_id 51 priority 101 virtual_ipaddress { 10.200.85.100 . . all the way to . 10.200.85.200 } An identical configuration is on the BACKUP machine, and it's working fine, but only up to the 20th IP. I have found a HOWTO discussing this problem. Basically, they suggest having just one VIP and routing all traffic "via" this one IP, and "all will be well". Is this a good approach? I'm running pfSense firewalls in front of the machines. Quote from the above link: ip route add $VNET/N via $VIP or route add $VNET netmask w.x.y.z gw $VIP Thanks in advance. EDIT: @David Schwartz said it would make sense to add a route, so I tried adding a static route to the pfSense firewall, but that didn't work as I expected it would. pfSense route: Interface: LAN Destination network: 10.200.85.200/32 (virtual IP) Gateway: 10.200.85.100 (floating virtual IP) Description: Route to VIP .100 I also made sure I had packet forwarding enabled on my hosts: $ cat /etc/sysctl.conf net.ipv4.ip_forward=1 net.ipv4.ip_nonlocal_bind=1 Am I doing this wrong? I also removed all VIPs from the keepalived.conf so it only fails over 10.200.85.100.

    Read the article

  • What is the peak theoretical WiFi G user density? [closed]

    - by Bigbio2002
    I've seen a few WiFi capacity planning questions, and this one is related, but hopefully different enough not to be closed. Also, this is related specifically to 802.11g, but a similar question could be made for N. In order to squeeze more WiFi users into a space, the transmit power on the APs need to be reduced and the APs squeezed closer together. My question is, how far can you practically take this before the network becomes unusable? There will come a point where the transmit power is so weak that nobody will actually be able to pick up a connection, or be constantly roaming to/from APs spaced a few feet apart as they walk around. There are also only 3 available channels to use as well, which is a factor to consider. After determining the peak AP density, then multiply by users-per-AP, which should be easier to find out. After factoring all of this in and running some back-of-the-envelope calculations, I'd like to be able to get a figure of "XX users per 10ft^2" or something. This can be considered the physical limit of WiFi, and will keep people from asking about getting 3,000 people in a ballroom conference on WiFi. Can anyone with WiFi experience chime in, or better yet, provide some calculations for a more accurate figure? Assumptions: Let's assume an ideal environment with no reflection (think of a big, square, open room, with the APs spaced out on a plane), APs are placed on the ceiling so humans won't absorb the waves, and the only interference are from the APs themselves and the devices. As for what devices specifically, that's irrelevant for the first point of the question (AP density, so only channel and transmit power should matter). User experience: Wikipedia states that Wireless G has about 22Mbps maximum effective throughput, or about 2.75MB/s. For the purpose of this question, anything below 100KB/s per user can be deemed to be a poor user experience. As for roaming, I'll assume the user is standing in the same place, so hopefully that will be a non-issue.

    Read the article

< Previous Page | 119 120 121 122 123 124 125 126 127 128 129 130  | Next Page >