  • Setting up UPS monitoring

    - by Andrew Heath
    I have acquired a second hand Uninterrupted Power Supply (UPS) that I have refurbished (new battery) and hope to use with my Ubuntu 12.10 system. It's a SOLA 330 with serial out. I have installed NUT Metapackage and NUT Monitor from Software Centre, but am not sure how to go about setting it all up. A Google search brings up several ways of configuring Network UPS Tools (NUT) or HAL-Drivers, however, HAL-Drivers appears to be obsolete and many commands and config files mentioned to edit do not exist in 12.10 or the current version of NUT (most articles are a few years old). One tutorial seemed to work except the Error: no UPS definitions found in ups.conf even though ups.conf has values in it as laid out in the tutorial. How do I go about setting my system to monitor the UPS for a shut down signal? Also, is there a command to determine the UPS is communicating through the serial connection and on what port (to help with setup and configuring, eg. /dev/ttyS0 is mentioned in one of the tutorials I read).

    Read the article

  • Problems with NVIDIA drivers: White screen with full(or almost full)screen apps

    - by Felipe
    My NVIDIA graphic card is a 7050/610i. My problem is that after upgrading to the last NVIDIA drivers when I use fullscreen apps (or almost fullscreen) the windows goes white. My xorg.conf file: # nvidia-xconfig: X configuration file generated by nvidia-xconfig # nvidia-xconfig: version 270.29 ([email protected]) Wed Feb 23 16:38:34 PST 2011 Section "Monitor" Identifier "Monitor0" VendorName "Unknown" ModelName "Unknown" HorizSync 28.0 - 33.0 VertRefresh 43.0 - 72.0 Option "DPMS" EndSection Section "Screen" Identifier "Screen0" Device "Device0" Monitor "Monitor0" Option "AddARGBGLXVisuals" "True" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection Section "Module" Load "glx" EndSection Section "InputDevice" Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" Identifier "Keyboard0" Driver "kbd" # generated from default EndSection Section "ServerLayout" Identifier "Layout0" Screen 0 "Screen0" 0 0 InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" EndSection Section "Device" Identifier "Device0" VendorName "NVIDIA Corporation" Driver "nvidia" Option "NoLogo" "True" EndSection Any idea on how to solve this? <--Sorry for bad english, ask for more info--

    Read the article

  • Social Analytics and the Customer

    - by David Dorf
    Many successful retailers put the customer at the center of everything they do, so its important that the customer is modeled correctly across all their systems.  The path to omni-channel starts and ends with the customer so at ARTS, our next big project is focused on ensuring a consistent representation of customers across our transactional data model, datawarehouse model, and XML schemas.  Further, we've started a new whitepaper that describes how Big Data and Social Media Analytics should be leveraged by retailers to add and additional level of customer insight. Let's start by taking a closer look at the meaning of social analytics.  Here's my definition: Social Analytics, in the retail context, describes the analysis of data obtained from social media sources in an effort to better comprehend and interact with the community of consumers.  This discipline seeks to understand what’s being said by the community about brands and products (“monitoring”), as well as understand the behaviors of those in the community (“profiling”).  The results are used to enforce the brand image, improve product decisions, and better focus marketing, all of which lead to increased sales. To help illustrate the facets of social analytics, I drew the diagram below which was originally published by Retail Touchpoints. There are lots of tools on the market that allow retailers to monitor social media for brand and product mentions.  These include analysis of sentiment, reach, share of voice, engagement, etc.  When your brand is mentioned, good or bad, its an opportunity to engage with the customer and possibly lead to a sale.  Because products are not always unique, its much more difficult to monitor product mentions, but detecting product trends early can help a retailer make better merchandising decisions, especially in fashion. Once a retailer understands what's being said, the next step is learn more about who's saying it.  That involves profiling customers beyond simple demographics to understand their motivations.  Much can be learned from patterns, and even more when customers voluntarily share their data.  Knowing that a customer is passionate about, for example, mountain biking allows the retailer to make relevant offers on helmets, ask for opinions on hydration, and help spread marketing messages. Social analytics has many facets that benefit retailers, some of which are easy but many of which are hard.  Its important for the CMO and CIO to work closely together to plan for these capabilities and monitor the maturity of tools on the market.  This is an area that will separate winners from losers.

    Read the article

  • The Dude

    A freeware network monitor that maps and monitors your network and provides alerts when network issues pop up

    Read the article

  • Settings for multiple monitors are not stored

    - by JJD
    I am running Ubuntu 12.04. on a Lenovo Thinkpad T400. I connected an external monitor as a second display. The laptop stands under the external screen. The laptop has a native resolution of 1440x900 (16:10), the external monitor 1280x1024 (5:4). There are two graphic adapters: one internal Intel GMA 4500 MHD and an discrete ATI card. Currently, the integrated Intel is enabled. I use the Display application to arrange the position of the monitors so it look like this: The problem: Whenever I restart my computer the configuration gets lost. First, the displays are mirrored instead of extended. I have to press Fn + F7 two times to switch to extended mode. Second, the Display settings still look like this: I know this worked once when I was running Ubuntu 10.10. I cannot tell since when it does not work. Do you know how I can permanently store the settings?

    Read the article

  • Using a DisplayLink USB video adapter on Ubuntu 12.10

    - by Jason R
    The line of USB video adapters made by DisplayLink has a somewhat sordid history under Linux. In past Ubuntu releases, the process of getting them to work has been somewhat difficult, inspiring a number of past questions on this site: example 1 example 2 example 3 However, there are some indications that version 3.5 of the Linux kernel (which is used by 12.10) contains better support for these adapters, which should make them easier to use. I currently have a single-GPU machine (it is an Nvidia adapter) with dual monitor outputs. I would like to add the DisplayLink adapter to drive a third external monitor. How can I set this up on Ubuntu 12.10?

    Read the article

  • Change resolution in Waking Mars

    - by Wes
    I purchased and installed the humble bundle game "Waking Mars" via the Ubuntu Software Center and it works really well except for some issues with changing settings, namely with the resolution. The in-game settings for changing resolution and entering/exiting fullscreen were easy enough to find and toggle, and when you do it asks to restart the application. When you restart it, all other settings you updated are reflected except for the changes to the resolution. (I'm trying to get it to play in windowed mode that fits onto one monitor, but it will only default to windowed mode with the full dual monitor resolution). I noticed that it writes these values to ~/.local/share/WakingMars/UserSettings.ini. When I change the resolution, it is properly written to in this settings file...but it never is reflected when you restart the application. Any ideas what's wrong?

    Read the article

  • is the AOC e2239fwt supported for multi touch on any ubuntu distro?

    - by HybriDPjT
    as the title says i have the e2239fwt monitor and ive tried ubuntu 10.04, 10.10, 11.04, 12.04 and now 13.04 and i cant get it to work. i should state that the single point touch seems to work ok but thats all. ive already tried looking and found no answers so here i am asking the peeps in the know :) i am currently running 13.04 and possibly going back to 10.04 if i cant get it to work or find that this monitor is in fact not supported.. hybridpjt@Unicorn:~$ lsusb Bus 002 Device 002: ID 05e3:0610 Genesys Logic, Inc. 4-port hub Bus 003 Device 002: ID 045e:0780 Microsoft Corp. Bus 003 Device 003: ID 06a3:0cc3 Saitek PLC Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 002 Device 003: ID 0408:3001 Quanta Computer, Inc. Optical Touch Screen

    Read the article

  • Data Auditor by Example

    - by Jinjin.Wang
    OWB has a node Data Auditors under Oracle Module in Projects Navigator. What is data auditor and how to use it? I will give an introduction to data auditor and show its usage by examples. Data auditor is an important tool in ensuring that data quality levels meet business requirements. Data auditor validates data against a set of data rules to determine which records comply and which do not. It gathers statistical metrics on how well the data in a system complies with a rule by auditing and marking how many errors are occurring against the audited table. Data auditors are typically scheduled for regular execution as part of a process flow, to monitor the quality of the data in an operational environment such as a data warehouse or ERP system, either immediately after updates like data loads, or at regular intervals. How to use data auditor to monitor data quality? Only objects with data rules can be monitored, so the first step is to define data rules according to business requirements and apply them to the objects you want to monitor. The objects can be tables, views, materialized views, and external tables. Secondly create a data auditor containing the objects. You can configure the data auditor and set physical deployment parameters for it as optional, which will be used while running the data auditor. Then deploy and run the data auditor either manually or as part of the process flow. After execution, the data auditor sets several output values, and records that are identified as not complying with the defined data rules contained in the data auditor are written to error tables. Here is an example. We have two tables DEPARTMENTS and EMPLOYEES (see pic-1 and pic-2. Click here for DDL and data) imported into OWB. We want to gather statistical metrics on how well data in these two tables satisfies the following requirements: a. Values of the EMPLOYEES.EMPLOYEE_ID attribute are three-digit numbers. b. Valid values for EMPLOYEES.JOB_ID are IT_PROG, SA_REP, SH_CLERK, PU_CLERK, and ST_CLERK. c. EMPLOYEES.EMPLOYEE_ID is related to DEPARTMENTS.MANAGER_ID. Pic-1 EMPLOYEES Pic-2 DEPARTMENTS 1. To determine legal data within EMPLOYEES or legal relationships between data in different columns of the two tables, firstly we define data rules based on the three requirements and apply them to tables. a. The first requirement is about patterns that an attribute is allowed to conform to. We create a Domain Pattern List data rule EMPLOYEE_PATTERN_RULE here. The pattern is defined in the Oracle Database regular expression syntax as ^([0-9]{3})$ Apply data rule EMPLOYEE_PATTERN_RULE to table EMPLOYEES.

    Read the article

  • ADF Mobile Application in the Apple AppStore

    - by Joe Huang
    Hi, everyone: I would like to announce that there is now an iPhone App in the Apple AppStore that's built using Oracle ADF Mobile.  This app is the Hudson Mobile Monitor application for the iPhone, which allows you to monitor build status for the Hudson Continuous Integration server.  By default it points to the production instance of the Hudson CI server hosted at Oracle.  One of the key goals for ADF Mobile in general is to ensure an application built using ADF Mobile is compliant with Apple iOS SDK terms.  We designed the framework to ensure applications can go through the approval process - of course there are still things that can be done which would cause issues during the approval process, and we will be publishing more best practices in the coming articles. Thanks, ADF Mobile Product Management Team.

    Read the article

  • Shortcut to switch between Analog Stereo output & HDMI audio output

    - by iJeeves
    To switch to HDMI audio output (of monitor) and back to normal audio output from system audio jack (for headphones, as my monitor doesn't have audio out), I find myself opening up sound preferences and selecting the right channel everytime. Is there any way I can create a toggle button in the panel or assign some shortcut key to toggle since I do the switching so often. :aplay -l **** List of PLAYBACK Hardware Devices **** card 0: Intel [HDA Intel], device 0: STAC92xx Analog [STAC92xx Analog] Subdevices: 1/1 Subdevice #0: subdevice #0 card 0: Intel [HDA Intel], device 3: HDMI 0 [HDMI 0] Subdevices: 0/1 Subdevice #0: subdevice #0 card 0: Intel [HDA Intel], device 7: STAC92xx Digital [STAC92xx Digital] Subdevices: 1/1 Subdevice #0: subdevice #0

    Read the article

  • Why doesn't my graphic card software support 1280*1024?

    - by Allwar
    Hi, I have an external monitor which is an 20" 1280*1024. In windows 7 it works fine with that resolution but in ubuntu it can't. Example: In windows I connect it and activates it, done. In ubuntu I connect and the only resolution that is available is the ones my laptop screen support, 12" 1366*768. My laptop is an asus 1201n. If I force it to use 1280*1024 both screen crashes and i have to force a reboot. When I force it I only force the external monitor, the laptop is already at maximum 1366*768. I connect it throw VGA. ((The graphic card supports 1280*1024 in windows 7, #Fail)) alvar@alvars-laptop:~$ disper -l display DFP-0: HSD121PHW1 resolutions: 320x175, 320x200, 360x200, 320x240, 400x300, 416x312, 512x384, 640x350, 576x432, 640x400, 680x384, 720x400, 640x480, 720x450, 640x512, 700x525, 800x512, 840x525, 800x600, 960x540, 832x624, 1024x768, 1366x768 display CRT-0: CRT-0 resolutions: 320x240, 400x300, 512x384, 680x384, 640x480, 800x600, 1024x768, 1152x864, 1360x768

    Read the article

  • Week in Geek: Botnet Epidemic Fueled by Malware Toolkits Edition

    - by Asian Angel
    This week we learned how to stream media files from any PC to a PlayStation, enable user-specific wireless networks in Windows 7, monitor the bandwidth consumption of individual applications, configure the Linux Grub2 Boot Menu the easy way, “add Dropbox to the Start Menu, understand symbolic links, & rip TV Series DVDs into episode files”, and more Latest Features How-To Geek ETC How to Enable User-Specific Wireless Networks in Windows 7 How to Use Google Chrome as Your Default PDF Reader (the Easy Way) How To Remove People and Objects From Photographs In Photoshop Ask How-To Geek: How Can I Monitor My Bandwidth Usage? Internet Explorer 9 RC Now Available: Here’s the Most Interesting New Stuff Here’s a Super Simple Trick to Defeating Fake Anti-Virus Malware Comix is an Awesome Comics Archive Viewer for Linux Get the MakeUseOf eBook Guide to Speeding Up Windows for Free Need Tech Support? Call the Star Wars Help Desk! [Video Classic] Reclaim Vertical UI Space by Adding a Toolbar to the Left or Right Side of Firefox Androidify Turns You into an Android-style Avatar Reader for Android Updates; Now with Feed Widgets and More

    Read the article

  • Dark themes in IDE with multiple monitors [closed]

    - by nivlam
    There has been numerous posts about developers that prefer a dark color scheme in their IDE. Most of the themes at studiostyl.es are dark themes. Back when I had a single monitor, I did enjoy using a dark theme since it was easier on the eyes. But now that I utilize multiple monitors, I find dark themes actually hurt my eyes. Most of the time I have my IDE open on one monitor and a browser/email/documentation open on my other monitors. Only my IDE has a dark theme and most of websites/documentation have a white background. This forces my eyes to constantly adjust between my dark IDE and the white website, which puts strain on my eyes. I'm sure I'm not the only person who tries to use a dark theme for the IDE and have multiple monitors. How do other people deal with this issue?

    Read the article

  • Which of VLC's dependencies causes sound device detection?

    - by Raphael
    I am setting up a headless music server based on the minimal Ubuntu image. After having installed the packages openssh-server,pulseaudio, libmad0,flac,liboff0,libid3tag0,libvorbis0a,ffmpeg, mpd,mpc,mpdscribble, paman,paprefs,pavumeter neither my internal soundcard nor the external DAC where detected by pulseaudio, that is pactl list did only list the dummy devices. Several reboots did not change that. The hardware devices are detected properly: ~$ lsusb | grep Texas Bus 002 Device 002: ID 08bb:2706 Texas Instruments Japan ~$ lspci | grep Audio 00:1b.0 Audio device: Intel Corporation N10/ICH 7 Family High Definition Audio Controller (rev 02) Following a hunch, I installed vlc with all dependencies. After a reboot, both devices are detected! ~$ pactl list | grep "Sink: alsa_output" Monitor of Sink: alsa_output.pci-0000_00_1b.0.analog-stereo Monitor of Sink: alsa_output.usb-Burr-Brown_from_TI_USB_Audio_DAC-00-DAC.analog-stereo Now I would like to remove VLC again but keep the devices. The question is: which of the many dependencies of VLC enables proper device detection? And why on earth is it not a dependency of pulseaudio?

    Read the article

  • Mouse permanently stuck on left side of screen

    - by Alex
    One of my two monitors is died, so while my computer was turned off I unplugged the dead monitor then turned my computer back on. When I got to the log in page I typed my password and got to the desktop my mouse was stuck to the left edge of the screen. I can move it up and down, and left and right click, but it won't come off the edge. I tried switching the monitor cable to the other slot to see if that would make a difference but nothing changed. If it makes a difference, I'm using Kubuntu.

    Read the article

  • 3+ monitors, nvidia + intel graphics

    - by gozzilli
    I have seen lots of different posts on this issue, but I cannot figure out what to do. I hope we can collect the available information in one place, so that they can be useful for others. Is it possible to have multiple (3+) monitors running on two different graphics cards? I have 1x nVidia GeForce GTX 550 with 2 DVI ports and 1x Intel integrated graphics, with 2 DVI ports. I understand that they would be running on different instances of X servers. Is that correct? Could someone point me in the right direction to start? On Windows it's so simple, there is no additional thing to do other than going in display preferences and activating all 3+ monitors. They can even be laid out alternating one monitor from one graphics card with another monitor from the other card.

    Read the article

  • How can I fix broken i915 drivers for Intel GPUs?

    - by Alen Mujezinovic
    I've got troubles getting the i915 drivers to work correctly on my laptop (HP Pavilion DM4 2101ea). Specifically, the laptop screen goes black and stays black after the splash graphic when booting both from USB key and from harddrive. To get anything on to the display after the splash screen I have to boot either with acpi=off nomodeset i915.modeset=0 I'd rather not turn ACPI off because I like my fans spinning and nomodeset is a bit overkill, so for now I'm booting with i915.modeset=0. Unfortunately, this turns off KMS and my current maximum resolution on the laptop screen is fixed to 1024x768 instead of its real capability. When not setting any of the above boot flags and I plug in an external monitor, the external monitor works fine. When booting with the flags, the external monitor works fine too, but can only do 1024x768 and can't do anything else than mirroring the laptop display. I did upgrade the i915 drivers from 2.17 that ship with Precise to 2.19 which are the most recent ones but without luck of getting anything to display. Here's my lspci output: 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) 00:16.0 Communication controller: Intel Corporation 6 Series/C200 Series Chipset Family MEI Controller #1 (rev 04) 00:1a.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 (rev 05) 00:1b.0 Audio device: Intel Corporation 6 Series/C200 Series Chipset Family High Definition Audio Controller (rev 05) 00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5) 00:1c.2 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 3 (rev b5) 00:1c.4 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 5 (rev b5) 00:1d.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 (rev 05) 00:1f.0 ISA bridge: Intel Corporation HM65 Express Chipset Family LPC Controller (rev 05) 00:1f.2 SATA controller: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller (rev 05) 00:1f.3 SMBus: Intel Corporation 6 Series/C200 Series Chipset Family SMBus Controller (rev 05) 01:00.0 Network controller: Broadcom Corporation BCM4313 802.11b/g/n Wireless LAN Controller (rev 01) 02:00.0 Unassigned class [ff00]: Realtek Semiconductor Co., Ltd. RTS5116 PCI Express Card Reader (rev 01) 08:00.0 Ethernet controller: Atheros Communications Inc. AR8151 v2.0 Gigabit Ethernet (rev c0) Here's lshw -C video *-display UNCLAIMED description: VGA compatible controller product: 2nd Generation Core Processor Family Integrated Graphics Controller vendor: Intel Corporation physical id: 2 bus info: pci@0000:00:02.0 version: 09 width: 64 bits clock: 33MHz capabilities: msi pm vga_controller bus_master cap_list configuration: latency=0 resources: memory:c0000000-c03fffff memory:b0000000-bfffffff ioport:4000(size=64) Both outputs are generated after booting with i915.modeset=0. Here's a complete Xorg.log file from a boot into a black screen: https://gist.github.com/479ce06454e47d6123e1 The graphics card is a Intel HD 3000 integrated GPU. I've never had problems with Intel hardware on Ubuntu before so this is very surprising. If you could provide a method to make i915 work, suggest alternative drivers a way to boot with i915.modeset=0 but higher resolutions and KMS on or explain what is happening and how to fix it I'll give you an answer badge. :) Thanks

    Read the article

  • Disabling hardware checking in the start up

    - by sven
    I have a ubuntu (10.04) on my desktop and it doesn't have monitor. I would like to connect the desktop (ubuntu) via teamviewer from my laptop. However, when the PC is powered, pc gives an error about it could not find monitor and it gets stuck in this error and does not continue. Since the ubuntu started correclty, teamviewer doesnt start to work on ubuntu so that I can not connect to the ubuntu. How can I disable hardware/desktop checking at the startup, so that ubuntu would start normally then I can use teamviewer?

    Read the article

  • Hotkey to shut down from login screen?

    - by Skizz
    I used to run 9.04 on my server and used to be able to use Alt-T, Alt-S to shut the system down from the login screen. It was using a KDE login screen. Now I've upgraded to 10.04 and use the Gnome login screen and I can't see any keyboard shortcuts to shutdown the server. Is there a shortcut and if so, what is it? Further info - I would normally shut down the server without turning on the monitor, which was easy using the keyboard shortcuts. Doing it with a mouse is not so easy without the monitor being on.

    Read the article

  • Black bars around screen? Catalyst Control Center problem?

    - by Josh B
    I just newly install Ubuntu 12.04, and im running an HDMI cable from my computer to my ASUS monitor. Now in Windows 7, i did not have these black bar issues running at 1080p. But now in Ubuntu, i have these black bars. I installed the ATI Catalyst Control Center, and I went to go in to fix the scaling but it is grayed out. As you can see, even with the override box checked i still can not set the scaling. The monitor was set to a lower resolution to hopefully fix it but that did not work either. Does anyone know how to fix this? Thanks.

    Read the article

  • Nvidia GT218 repository drivers don't work

    - by user1042840
    I upgraded all packages with sudo apt-get upgrade command on my Ubuntu 10.04 box and I have Ubuntu 12.04 3.2.0-29-generic-pae now. I have two monitors and the following GPU: 01:00.0 VGA compatible controller: NVIDIA Corporation GT218 [NVS 300] (rev a2) After upgrading to 12.04, I somehow lost my previous setup with one common workspace stretched across two monitors. When Ubuntu starts only one monitor is on. I can see the message on the active monitor: Not optimum mode. Recommended mode: 1680x1050 60Hz I used Nvidia proprietary drivers on 10.04 but now jockey-text --list shows: xorg:nvidia_current - NVIDIA accelerated graphics driver (Proprietary, Disabled, Not in use) xorg:nvidia_current_updates - NVIDIA accelerated graphics driver (post-release updates) (Proprietary, Enabled, Not in use) When I run sudo nvidia-settings it says You do not appear to be using the NVIDIA X driver. Please edit your X configuration file (just run `nvidia-xconfig` as root), and restart the X server.' I typed nvidia-xconfig and rebooted, but jockey-text --list says the same after the reboot: Not in use. The same with nvidia-current - Enabled but Not in use. I also tried nvidia-173 but I ended up in tty immediately at startup so I removed it. I used to have some problems with Nvidia proprietary drivers on 10.04, I had to put paths to EDID files in /etc/X11/xorg.conf explicitly, but the resolution was as recommended and both monitors were working. If I understand correctly, nouveau drivers are used now by default because the resolution is still quite high, definitely not 800x600, xrandr showed: xrandr: Failed to get size of gamma for output default Screen 0: minimum 320 x 400, current 1600 x 1200, maximum 1600 x 1200 default connected 1600x1200+0+0 0mm x 0mm 1600x1200 66.0* 1280x1024 76.0 1024x768 76.0 800x600 73.0 640x480 73.0 640x400 0.0 320x400 0.0 1680x1050_60.00 (0x4f) 146.2MHz h: width 1680 start 1784 end 1960 total 2240 skew 0 clock 65.3KHz v: height 1050 start 1053 end 1059 total 1089 clock 60.0Hz However, colors seem a bit faded and blurry with nouveau drivers. Mouse cursor is invisible if it's placed inside Firefox window, and only one monitor is working. I like open source and if it's possible I'd prefer to use nouveau drivers but a few things should be fixed. I'm curious why nvidia-current drivers from the repository don't work now. I read it has something to do with the new X11 server in Ubuntu 12.04, is it true? How can I get it back to work?

    Read the article

  • ldirectord ipvsadm not show reals ip and not work wtih pacemaker and corosync

    - by miguer27
    first thanks for your time. I'm having a problem with ldirectord that I can not solve, I comment my situation: I have two nodes with pace maker and corosync and configure somes resources: root@ldap1:/home/mamartin# crm status Last updated: Tue Jun 3 12:58:30 2014 Last change: Tue Jun 3 12:23:47 2014 via cibadmin on ldap1 Stack: openais Current DC: ldap2 - partition with quorum Version: 1.1.7-ee0730e13d124c3d58f00016c3376a1de5323cff 2 Nodes configured, 2 expected votes 7 Resources configured. Online: [ ldap1 ldap2 ] Resource Group: IPV_LVS IPV_4 (ocf::heartbeat:IPaddr2): Started ldap1 IPV_6 (ocf::heartbeat:IPv6addr): Started ldap1 lvs (ocf::heartbeat:ldirectord): Started ldap1 Clone Set: clon_IPV_lo [IPV_lo] Started: [ ldap2 ] Stopped: [ IPV_lo:1 ] root@ldap1:/home/mamartin# crm configure show node ldap2 \ attributes standby="off" node ldap1 \ attributes standby="off" primitive IPV-lo_4 ocf:heartbeat:IPaddr \ params ip="192.168.1.10" cidr_netmask="32" nic="lo" \ op monitor interval="5s" primitive IPV-lo_6 ocf:heartbeat:IPv6addrLO \ params ipv6addr="[fc00:1::3]" cidr_netmask="64" \ op monitor interval="5s" primitive IPV_4 ocf:heartbeat:IPaddr2 \ params ip="192.168.1.10" nic="eth0" cidr_netmask="25" lvs_support="true" \ op monitor interval="5s" primitive IPV_6 ocf:heartbeat:IPv6addr \ params ipv6addr="[fc00:1::3]" nic="eth0" cidr_netmask="64" \ op monitor interval="5s" primitive lvs ocf:heartbeat:ldirectord \ params configfile="/etc/ldirectord.cf" \ op monitor interval="20" timeout="10" \ meta target-role="Started" group IPV_LVS IPV_4 IPV_6 lvs group IPV_lo IPV-lo_6 IPV-lo_4 clone clon_IPV_lo IPV_lo \ meta interleave="true" target-role="Started" location cli-prefer-IPV_LVS IPV_LVS \ rule $id="cli-prefer-rule-IPV_LVS" inf: #uname eq ldap1 colocation LVS_no_IPV_lo -inf: clon_IPV_lo IPV_LVS property $id="cib-bootstrap-options" \ dc-version="1.1.7-ee0730e13d124c3d58f00016c3376a1de5323cff" \ cluster-infrastructure="openais" \ expected-quorum-votes="2" \ no-quorum-policy="ignore" \ stonith-enabled="false" \ last-lrm-refresh="1401264327" rsc_defaults $id="rsc-options" \ resource-stickiness="1000" The problem is in the ipvsadm only show a one real IP, when i configured two now, show the ldirector.cf: root@ldap1:/home/mamartin# ipvsadm IP Virtual Server version 1.2.1 (size=4096) Prot LocalAddress:Port Scheduler Flags - RemoteAddress:Port Forward Weight ActiveConn InActConn TCP ldap-maqueta.cica.es:ldap wrr - ldap2.cica.es:ldap Route 4 0 0 TCP [[fc00:1::3]]:ldap wrr - [[fc00:1::2]]:ldap Route 4 0 0 root@ldap1:/home/mamartin# cat /etc/ldirectord.cf checktimeout=10 checkinterval=2 autoreload=yes logfile="/var/log/ldirectord.log" quiescent=yes #ipv4 virtual=192.168.1.10:389 real=192.168.1.11:389 gate 4 real=192.168.1.12:389 gate 4 scheduler=wrr protocol=tcp checktype=on #ipv6 virtual6=[[fc00:1::3]]:389 real6=[[fc00:1::1]]:389 gate 4 real6=[[fc00:1::2]]:389 gate 4 scheduler=wrr protocol=tcp checkport=389 checktype=on and in the logs I see nothing clear: root@ldap1:/home/mamartin# ldirectord -d /etc/ldirectord.cf start DEBUG2: Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.11:389 -g -w 0) Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.11:389 -g -w 0) DEBUG2: Quiescent real server: 192.168.1.11:389 (192.168.1.10:389) (Weight set to 0) Quiescent real server: 192.168.1.11:389 (192.168.1.10:389) (Weight set to 0) DEBUG2: Disabled real server=on:tcp:192.168.1.11:389:::4:gate:\/: (virtual=tcp:192.168.1.10:389) DEBUG2: Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.12:389 -g -w 0) Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.12:389 -g -w 0) DEBUG2: Quiescent real server: 192.168.1.12:389 (192.168.1.10:389) (Weight set to 0) Quiescent real server: 192.168.1.12:389 (192.168.1.10:389) (Weight set to 0) DEBUG2: Disabled real server=on:tcp:192.168.1.12:389:::4:gate:\/: (virtual=tcp:192.168.1.10:389) DEBUG2: Checking on: Real servers are added without any checks DEBUG2: Resetting soft failure count: 192.168.1.12:389 (tcp:192.168.1.10:389) Resetting soft failure count: 192.168.1.12:389 (tcp:192.168.1.10:389) DEBUG2: Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.12:389 -g -w 4) Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.12:389 -g -w 4) Destination already exists root@ldap1:/home/mamartin# cat /var/log/ldirectord.log [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Quiescent real server: 192.168.1.11:389 (192.168.1.10:389) (Weight set to 0) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Quiescent real server: 192.168.1.12:389 (192.168.1.10:389) (Weight set to 0) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Resetting soft failure count: 192.168.1.12:389 (tcp:192.168.1.10:389) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.12:389 -g -w 4) failed: [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Added real server: 192.168.1.12:389 (192.168.1.10:389) (Weight set to 4) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Resetting soft failure count: 192.168.1.11:389 (tcp:192.168.1.10:389) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Restored real server: 192.168.1.11:389 (192.168.1.10:389) (Weight set to 4) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Resetting soft failure count: [[fc00:1::2]]:389 (tcp:[[fc00:1::3]]:389) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] system(/sbin/ipvsadm -a -t [[fc00:1::3]]:389 -r [[fc00:1::2]]:389 -g -w 4) failed: [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Added real server: [[fc00:1::2]]:389 ([[fc00:1::3]]:389) (Weight set to 4) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Resetting soft failure count: [[fc00:1::1]]:389 (tcp:[[fc00:1::3]]:389) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Restored real server: [[fc00:1::1]]:389 ([[fc00:1::3]]:389) (Weight set to 4) do not know if this is a bug or a configuration error, can anyone help? Regards.

    Read the article