Search Results

Search found 89530 results on 3582 pages for 'file read'.

Page 129/3582 | < Previous Page | 125 126 127 128 129 130 131 132 133 134 135 136  | Next Page >

  • Can't read from RSOP_RegistryPolicySetting WMI class in root\RSOP namespace

    - by JCCyC
    The class is documented in http://msdn.microsoft.com/en-us/library/aa375050%28VS.85%29.aspx And from this page it seems it's not an abstract class: http://msdn.microsoft.com/en-us/library/aa375084%28VS.85%29.aspx But whenever I run the code below I get an "Invalid Class" exception in ManagementObjectSearcher.Get(). So, does this class exist or not? ManagementScope scope; ConnectionOptions options = new ConnectionOptions(); options.Username = tbUsername.Text; options.Password = tbPassword.Password; options.Authority = String.Format("ntlmdomain:{0}", tbDomain.Text); scope = new ManagementScope(String.Format("\\\\{0}\\root\\RSOP", tbHost.Text), options); scope.Connect(); ManagementObjectSearcher searcher = new ManagementObjectSearcher(scope, new ObjectQuery("SELECT * FROM RSOP_RegistryPolicySetting")); foreach (ManagementObject queryObj in searcher.Get()) { wmiResults.Text += String.Format("id={0}\n", queryObj["id"]); wmiResults.Text += String.Format("precedence={0}\n", queryObj["precedence"]); wmiResults.Text += String.Format("registryKey={0}\n", queryObj["registryKey"]); wmiResults.Text += String.Format("valueType={0}\n", queryObj["valueType"]); } In the first link above, it lists as a requirement something called a "MOF": "Rsopcls.mof". Is this something I should have but have not? How do I obtain it? Is it necessary in the querying machine or the queried machine? Or both? I do have two copies of this file: C:\Windows>dir rsop*.mof /s Volume in drive C has no label. Volume Serial Number is 245C-A6EF Directory of C:\Windows\System32\wbem 02/11/2006 05:22 100.388 rsop.mof 1 File(s) 100.388 bytes Directory of C:\Windows\winsxs\x86_microsoft-windows-grouppolicy-base-mof_31bf3856ad364e35_6.0.6001.18000_none_f2c4356a12313758 19/01/2008 07:03 100.388 rsop.mof 1 File(s) 100.388 bytes Total Files Listed: 2 File(s) 200.776 bytes 0 Dir(s) 6.625.456.128 bytes free

    Read the article

  • how to read http response soap headers from web service response in proxy class

    - by Fabricio
    I'm having some problems with one webservice that i'm working with. I generated a proxy class with wsdl.exe that comes with .net framework. But that webservice return a header that isnt not mapped by the wsdl. I must map the header sop because it contains some properties that i have to read and work with. how can i read the soap's header collection? Ex.: <soap:Envelope xmlns:soap="http://schemas.xmlsoap.org/soap/envelope/"> <soap:Header xmlns="http://xml.amadeus.com/ws/2009/01/WBS_Session-2.0.xsd"> <Session> <SessionId>545784545</SessionId> <SequenceNumber>1</SequenceNumber> <SecurityToken>asd7a87sda89sd45as4d5a4</SecurityToken> </Session> </soap:Header> <soap:Body> <TAM_Altea_Seguranca_AutenticarRS xmlns="http://xml.amadeus.com/2009/04/TAM/TAM_Altea_Seguranca_AutenticarRS_2.0"> <statusDoProcesso> <codigoDoStatus>P</codigoDoStatus> </statusDoProcesso> </TAM_Altea_Seguranca_AutenticarRS> </soap:Body> </soap:Envelope> I need to read the SOAP:HEADER - Session.

    Read the article

  • SSIS: "Failure inserting into the read-only column <ColumnName>"

    - by Cory
    I have an Excel source going into an OLE DB destination. I'm inserting data into a view that has an INSTEAD OF trigger that handles all inserts. When I try to execute the package I receive this error: "Failure inserting into the read-only column ColumnName" What can I do to let SSIS know that this view is safe to insert into because there is an INSTEAD OF trigger that will handle the insert? EDIT (Additional info): Some more additional info. I have a flat file that is being inserted into a normalized database. My initial problem was how do I take a flat file and insert that data into multiple tables while keeping track of all the primary/foreign key relationships. My solution was to create a VIEW that mimicked the structure of the flat file and then create an INSTEAD OF trigger on that view. In my INSTEAD OF trigger I would handle the logic of maintaining all the relationships between tables My view looks something like this. CREATE VIEW ImportView AS SELECT CONVERT(varchar(100, NULL) AS CustomerName, CONVERT(varchar(100), NULL) AS Address1, CONVERT(varchar(100), NULL) AS Address2, CONVERT(varchar(100), NULL) AS City, CONVERT(char(2), NULL) AS State, CONVERT(varchar(250), NULL) AS ItemOrdered, CONVERT(int, NULL) AS QuantityOrdered ... I will never need to select from this view, I only use it to insert data into it from this flat file I receive. I need someway to tell SQL Server that the fields aren't really read only because there is an INSTEAD OF trigger on this view.

    Read the article

  • Read text file into listbox collections

    - by Arcadian
    Hi, i'm new to C#. I need my program to show different parts of the data contained in a txt file into different listboxs (which are on different tabs of a form) so that the user can see the particular block of data they are interested in. the data contained in the txt file looks like this: G30:39:03:31 JG06 G32:56:36:10 JG04 G31:54:69:52 JG04 G36:32:53:11 JG05 G33:50:05:11 JG06 G39:28:81:21 JG01 G39:22:74:11 JG06 G39:51:44:21 JG03 G39:51:52:22 JG01 G39:51:73:21 JG01 G35:76:24:20 JG06 G35:76:55:11 JG01 G36:31:96:11 JG02 G36:31:96:23 JG02 G36:31:96:41 JG03 though much more of it :) The separate listboxes will contain only the lines who's first integer pair matches that listbox's name. For example, all the lines that start "G32" will be added to the G32 listbox. I think the code would start something like: private void ReadToBox() { FileInfo file = new FileInfo("Jumpgate List.JG"); StreamReader objRead = file.OpenText(); while (!objRead.EndOfStream) but i'm not sure where to start in terms of getting it sorted yet. Any help? There's some rep in it for you :D

    Read the article

  • Read IFrame content using JavaScript

    - by Rajat
    Ok, This is my first time dealing seriously with IFrames and I cant seem to understand a few things: First the sample code I am testing with: <head> <script type="text/javascript"> function init(){ console.log("IFrame content: " + window.frames['i1'].document.getElementsByTagName('body')[0].innerHTML); } </script> </head> <body onload="init();"> <iframe name="i1" src="foo.txt"/> </body> the file "foo.txt" looks like this: sample text file Questions: 1) The iframe seems to be behaving as a HTML document and the file text is actually part of the body instead. Why ? Is it a rule for an IFrame to be a HTML document. Is it not possible for the content of an iframe to be just plain text ?? 2) The file content gets wrapped inside a pre tag for some reason. Why is this so ? Is it always the case? 3) My access method in the javascript is working but is there any other alternative? [native js solutions please] If the content is wrapped in a pre tag always then I will actually have to lookup inside the pre tag rather than lookup the innerHTML

    Read the article

  • How to fetch populated associated models in CakePHP when calling read()

    - by Code Commander
    I have the following Models: class Site extends AppModel { public $name = "Site"; public $useTable = "site"; public $primaryKey = "id"; public $displayField = 'name'; public $hasMany = array('Item' => array('foreignKey' => 'siteId')); public function canView($userId, $isAdmin = false) { if($isAdmin) { return true; } return array_key_exists($this->id, $allowedSites); } } and class Item extends AppModel { public $name = "Item"; public $useTable = "item"; public $primaryKey = "id"; public $displayField = 'name'; public $belongsTo = array('Site' => array('foreignKey' => 'siteId')); public function canView($userId, $isAdmin = false) { // My problem appears to be the next line: return $this->Site->canView($userId, $isAdmin); } } In my controller I am doing something like this: $result = $this->Item->read(null, $this->request->id); // Verify permissions if(!$this->Item->canView($this->Session->read('userId'), $this->Session->read('isAdmin'))) { $this->httpCodes(403); die('Permission denied.'); } I notice that in Item->canView() $this->data['Site'] is populated with the column data from the site table. But it merely an array and not an object. On the other hand $this->Site is a Site object, but it has not been populated with the column data from the site table like $this->data. What is the proper way to have CakePHP get the associated model as the object and containing the data? Or am I going about this all wrong? Thanks!

    Read the article

  • On the search for my next great .Net Read

    - by user127954
    Just got done with "The art of unit testing". It was a great read and i think everyone should go buy a copy. With that said i think the next book I'm like to read would be a architecture / Design type book that would focus heavily on building your objects / software in such a way that it would be: Low Coupling High Cohesion Easily Maintainable / Extended Easy to test Easy to Navigate / Debug The above characteristcs are the most important ones but also maybe it would also include (but not necessary) designing for: Performance - Don't want to design a system at at the end find out its dog slow :) Scalability - Again don't want to design something at the end find out it won't scale. I'd also prefer (but not necessary again): Something newer - Architectural principles seem to gradually evolve / improve over time and id like something with current thinking. .Net as illustrating language - like i said above its not mandatory but since its what i use every day id prefer it to be in .net. Doesn't really matter if its in vb.net or c# Some of the topics that would be talked about its how to minimize dependencies and using interfaces throughout your solution rather than concrete classes. Maybe it would constract /compare some of the newest design principles like DDD, Repository Pattern, Ect... I already have "Clean Code" (don't know if its this type of book or not) and "Working effectively with legacy code" on my radar but id like to read a book based upon the topic i talked about above first. Is there such a book?

    Read the article

  • PowerPoint PlugIn does not read defaults from .dll.config file

    - by Nick T
    I'm working on a very simple PowerPoint plugin, and I'm quite a bit stumped. In my settings.settings file, I have configured a setting "StartPath", which references where the PowerPoint plugin will navigate to using a Browser component. After I compile the application, and run the installer generated by the Setup project, the application is installed and uses the default value in the settings file. However, if I edit the application.dll.config file, the plugin still uses the old values. How can I set things up such that the plugin references the .dll.config file and not its default settings? The code to access the settings is listed below, including the other variants I have tried: //Attempt 1 string location = MyApplication.Properties.Settings.Default.StartPath; //Attempt 2 string location = ConfigurationManager.AppSettings["StartPath"]; //Attempt 3: Configuration element is inaccessible due to its protection level string applicationName = Environment.GetCommandLineArgs()[0] + ".exe"; string exePath = System.IO.Path.Combine(Environment.CurrentDirectory, applicationName); Configuration config = ConfigurationManager.OpenExeConfiguration(exePath); string location = config.AppSettings["StartPath"];

    Read the article

  • C# xml read, show error

    - by gloris
    Whats wrong with my code? XmlTextReader textReader = new XmlTextReader(@"D:\xml_file.xml"); textReader.Read(); // If the node has value while (textReader.Read()) { // Move to fist element textReader.MoveToElement(); Console.WriteLine("XmlTextReader Properties Test"); Console.WriteLine("==================="); // Read this element's properties and display them on console Console.WriteLine("id:" + textReader.id.ToString()); Console.WriteLine("name:" + textReader.name.ToString()); Console.WriteLine("time:" + textReader.time.ToString()); } Console.ReadLine() show erron on: id, name, time My XML file: <students> <student> <id>1</id> <name>Rikko Nora</name> <time>2010-03-12</time> </student> <student> <id>2</id> <name>Rikko Nora2</name> <time>2010-05-15</time> </student> </students>

    Read the article

  • Read varbinary data in java

    - by masoud farahani
    I made a Java application which reads some files from SQL server. Those files are saved to a varbinary(MAX) field in SQL Server by a third party web service. My problem is that when I want to read those files with my Java application, those binary data show different content in the Java application. In fact, I read data byte by byte and I figured out that some bytes did not show the real values which were saved in the database. I found out what the problem is, but I couldn’t find a solution yet. I found out that in the web service every varbinary data is saved to database as byte data (in .Net each byte takes 0 to 255). But, when I want to read the binary data in Java, it takes different values and cause an exception with some values, because in Java a byte value takes -127 to 127. In my Java application I want to write those data to a file by OutputStream.write(byte[]) method. How can I solve this problem? I think that I have to find a way to convert c# byte[] to a Java byte[] (or binary data), but how can I do that?

    Read the article

  • Multithreading: Read from / write to a pipe

    - by Tero Jokinen
    I write some data to a pipe - possibly lots of data and at random intervals. How to read the data from the pipe? Is this ok: in the main thread (current process) create two more threads (2, 3) the second thread writes sometimes to the pipe (and flush-es the pipe?) the 3rd thread has infinite loop which reads the pipe (and then sleeps for some time) Is this so far correct? Now, there are a few thing I don't understand: do I have to lock (mutex?) the pipe on write? IIRC, when writing to pipe and its buffer gets full, the write end will block until I read the already written data, right? How to check for read data in the pipe, not too often, not too rarely? So that the second thread wont block? Is there something like select for pipes? It is possible to set the pipe to unbuffered more or I have to flush it regularly - which one is better? Should I create one more thread, just for flushing the pipe after write? Because flush blocks as well, when the buffer is full, right? I just don't want the 1st and 2nd thread to block.... [Edit] Sorry, I thought the question is platform agnostic but just in case: I'm looking at this from Win32 perspective, possibly MinGW C...

    Read the article

  • Using Read-Only Fields in a C# WebBrowser

    - by TheDramaLlama
    I'm currently using a WebBrowser control in a C# WinForms application, and attempting to control some variability presented with this control. Basically, my users log in to a separate UI provided by my application, which then displays the WebBrowser control, navigates to a predetermined log-in URL, and then auto-fills the username and password fields on that page. However, in order to prevent unpredictable behavior in this WebBrowser control, I want to make these username and password text boxes read-only after they are auto-populated. Essentially, I want the user to see a browser page that has been filled out for them, and that cannot be edited. (This is so that any authentication errors can be handled by my application as opposed to the browser.) The code I'm currently using to populate the text fields and make them read only is as follows: webBrowser1.Document.GetElementById("username").InnerText = username; webBrowser1.Document.GetElementById("password").InnerText = password; webBrowser1.Document.GetElementById("username").Enabled = false; webBrowser1.Document.GetElementById("password").Enabled = false; Unfortunately, when I try to make the fields read-only, the authentication server acts like the password field was not filled out, and prompts the user to fill it out again after the "Submit" button is clicked. Is this expected behavior, and if so, what other methods can I try to prevent users from changing the credentials that the browser was auto-populated with?

    Read the article

  • how to tune BufferedInputStream read()?

    - by technomax
    I am reading a BLOB column from a Oracle database, then writing it to a file as follows: public static int execute(String filename, BLOB blob) { int success = 1; try { File blobFile = new File(filename); FileOutputStream outStream = new FileOutputStream(blobFile); BufferedInputStream inStream = new BufferedInputStream(blob.getBinaryStream()); int length = -1; int size = blob.getBufferSize(); byte[] buffer = new byte[size]; while ((length = inStream.read(buffer)) != -1) { outStream.write(buffer, 0, length); outStream.flush(); } inStream.close(); outStream.close(); } catch (Exception e) { e.printStackTrace(); System.out.println("ERROR(img_exportBlob) Unable to export:"+filename); success = 0; } } The file size is around 3MB and it takes 40-50s to read the buffer. Its actually a 3D image data. So, is there any way by which I can reduce this time?

    Read the article

  • Reading a text file, and performing actions based on strings read

    - by user1691766
    Let me start off by saying that I really am quite new to C. So basically I have a text file (contains around 30 assembly instructions, separated by new lines), and I am successfully reading them into my program. From here I need to perform certain actions based off each instruction. I would assume the best way to do this would be via a switch-case statement. However I am encountering a lot of problems due to me trying to compare strings that are 33 characters long. Can anyone please offer me advice on what I am doing wrong, or offer an alternative? Thanks in advance. Here is what I have so far: char instruction[29][ 33 ]; int i,run; i = 0; run = 1; FILE *instPtr; /* LOADING INSTRUCTIONS FROM FILE INTO "instruction" ARRAY*/ if ( ( instPtr = fopen("MIPSinstructions.txt", "r") ) == NULL ) { printf("File could not be opened\n"); } // end if else { fscanf( instPtr, "%s", instruction[0]); printf("%s\n", instruction[0]); while (!feof( instPtr ) ){ i++; fscanf( instPtr, "%s", instruction[i]); printf("%s\n", instruction[i]); } fclose( instPtr ); i = 0; // Reset the counter } //end else return 0; }

    Read the article

  • How to determine the format of Excel file in Java?

    - by Samuh
    I am working on a light weight Java client library for Android mobile platform that can read and write to Excel files in .xls(BIFF) and Office 2003 XML format. No sooner we decided to start than we got stuck with a basic question. How do we determine the format of the excel files in Java? Please help. Thanks.

    Read the article

  • An easy way to create Side by Side registrationless COM Manifests with Visual Studio

    - by Rick Strahl
    Here's something I didn't find out until today: You can use Visual Studio to easily create registrationless COM manifest files for you with just a couple of small steps. Registrationless COM lets you use COM component without them being registered in the registry. This means it's possible to deploy COM components along with another application using plain xcopy semantics. To be sure it's rarely quite that easy - you need to watch out for dependencies - but if you know you have COM components that are light weight and have no or known dependencies it's easy to get everything into a single folder and off you go. Registrationless COM works via manifest files which carry the same name as the executable plus a .manifest extension (ie. yourapp.exe.manifest) I'm going to use a Visual FoxPro COM object as an example and create a simple Windows Forms app that calls the component - without that component being registered. Let's take a walk down memory lane… Create a COM Component I start by creating a FoxPro COM component because that's what I know and am working with here in my legacy environment. You can use VB classic or C++ ATL object if that's more to your liking. Here's a real simple Fox one: DEFINE CLASS SimpleServer as Session OLEPUBLIC FUNCTION HelloWorld(lcName) RETURN "Hello " + lcName ENDDEFINE Compile it into a DLL COM component with: BUILD MTDLL simpleserver FROM simpleserver RECOMPILE And to make sure it works test it quickly from Visual FoxPro: server = CREATEOBJECT("simpleServer.simpleserver") MESSAGEBOX( server.HelloWorld("Rick") ) Using Visual Studio to create a Manifest File for a COM Component Next open Visual Studio and create a new executable project - a Console App or WinForms or WPF application will all do. Go to the References Node Select Add Reference Use the Browse tab and find your compiled DLL to import  Next you'll see your assembly in the project. Right click on the reference and select Properties Click on the Isolated DropDown and select True Compile and that's all there's to it. Visual Studio will create a App.exe.manifest file right alongside your application's EXE. The manifest file created looks like this: xml version="1.0" encoding="utf-8"? assembly xsi:schemaLocation="urn:schemas-microsoft-com:asm.v1 assembly.adaptive.xsd" manifestVersion="1.0" xmlns:asmv1="urn:schemas-microsoft-com:asm.v1" xmlns:asmv2="urn:schemas-microsoft-com:asm.v2" xmlns:asmv3="urn:schemas-microsoft-com:asm.v3" xmlns:dsig="http://www.w3.org/2000/09/xmldsig#" xmlns:co.v1="urn:schemas-microsoft-com:clickonce.v1" xmlns:co.v2="urn:schemas-microsoft-com:clickonce.v2" xmlns="urn:schemas-microsoft-com:asm.v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" asmv2:size="27293" hash xmlns="urn:schemas-microsoft-com:asm.v2" dsig:Transforms dsig:Transform Algorithm="urn:schemas-microsoft-com:HashTransforms.Identity" / dsig:Transforms dsig:DigestMethod Algorithm="http://www.w3.org/2000/09/xmldsig#sha1" / dsig:DigestValuepuq+ua20bbidGOWhPOxfquztBCU=dsig:DigestValue hash typelib tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" version="1.0" helpdir="" resourceid="0" flags="HASDISKIMAGE" / comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file assembly Now let's finish our super complex console app to test with: using System; using System.Collections.Generic; using System.Text; namespace ConsoleApplication1 {     class Program     {         static voidMain(string[] args)         { Type type = Type.GetTypeFromProgID("simpleserver.simpleserver",true); dynamic server = Activator.CreateInstance(type); Console.WriteLine(server.HelloWorld("rick")); Console.ReadLine(); } } } Now run the Console Application… As expected that should work. And why not? The COM component is still registered, right? :-) Nothing tricky about that. Let's unregister the COM component and then re-run and see what happens. Go to the Command Prompt Change to the folder where the DLL is installed Unregister with: RegSvr32 -u simpleserver.dll      To be sure that the COM component no longer works, check it out with the same test you used earlier (ie. o = CREATEOBJECT("SimpleServer.SimpleServer") in your development environment or VBScript etc.). Make sure you run the EXE and you don't re-compile the application or else Visual Studio will complain that it can't find the COM component in the registry while compiling. In fact now that we have our .manifest file you can remove the COM object from the project. When you run run the EXE from Windows Explorer or a command prompt to avoid the recompile. Watch out for embedded Manifest Files Now recompile your .NET project and run it… and it will most likely fail! The problem is that .NET applications by default embeds a manifest file into the compiled EXE application which results in the externally created manifest file being completely ignored. Only one manifest can be applied at a time and the compiled manifest takes precedency. Uh, thanks Visual Studio - not very helpful… Note that if you use another development tool like Visual FoxPro to create your EXE this won't be an issue as long as the tool doesn't automatically add a manifest file. Creating a Visual FoxPro EXE for example will work immediately with the generated manifest file as is. If you are using .NET and Visual Studio you have a couple of options of getting around this: Remove the embedded manifest file Copy the contents of the generated manifest file into a project manifest file and compile that in To remove an embedded manifest in a Visual Studio project: Open the Project Properties (Alt-Enter on project node) Go down to Resources | Manifest and select | Create Application without a Manifest   You can now add use the external manifest file and it will actually be respected when the app runs. The other option is to let Visual Studio create the manifest file on disk and then explicitly add the manifest file into the project. Notice on the dialog above I did this for app.exe.manifest and the manifest actually shows up in the list. If I select this file it will be compiled into the EXE and be used in lieu of any external files and that works as well. Remove the simpleserver.dll reference so you can compile your code and run the application. Now it should work without COM registration of the component. Personally I prefer external manifests because they can be modified after the fact - compiled manifests are evil in my mind because they are immutable - once they are there they can't be overriden or changed. So I prefer an external manifest. However, if you are absolutely sure nothing needs to change and you don't want anybody messing with your manifest, you can also embed it. The option to either is there. Watch for Manifest Caching While working trying to get this to work I ran into some problems at first. Specifically when it wasn't working at first (due to the embedded schema) I played with various different manifest layouts in different files etc.. There are a number of different ways to actually represent manifest files including offloading to separate folder (more on that later). A few times I made deliberate errors in the schema file and I found that regardless of what I did once the app failed or worked no amount of changing of the manifest file would make it behave differently. It appears that Windows is caching the manifest data for a given EXE or DLL. It takes a restart or a recompile of either the EXE or the DLL to clear the caching. Recompile your servers in order to see manifest changes unless there's an outright failure of an invalid manifest file. If the app starts the manifest is being read and caches immediately. This can be very confusing especially if you don't know that it's happening. I found myself always recompiling the exe after each run and before making any changes to the manifest file. Don't forget about Runtimes of COM Objects In the example I used above I used a Visual FoxPro COM component. Visual FoxPro is a runtime based environment so if I'm going to distribute an application that uses a FoxPro COM object the runtimes need to be distributed as well. The same is true of classic Visual Basic applications. Assuming that you don't know whether the runtimes are installed on the target machines make sure to install all the additional files in the EXE's directory alongside the COM DLL. In the case of Visual FoxPro the target folder should contain: The EXE  App.exe The Manifest file (unless it's compiled in) App.exe.manifest The COM object DLL (simpleserver.dll) Visual FoxPro Runtimes: VFP9t.dll (or VFP9r.dll for non-multithreaded dlls), vfp9rENU.dll, msvcr71.dll All these files should be in the same folder. Debugging Manifest load Errors If you for some reason get your manifest loading wrong there are a couple of useful tools available - SxSTrace and SxSParse. These two tools can be a huge help in debugging manifest loading errors. Put the following into a batch file (SxS_Trace.bat for example): sxstrace Trace -logfile:sxs.bin sxstrace Parse -logfile:sxs.bin -outfile:sxs.txt Then start the batch file before running your EXE. Make sure there's no caching happening as described in the previous section. For example, if I go into the manifest file and explicitly break the CLSID and/or ProgID I get a detailed report on where the EXE is looking for the manifest and what it's reading. Eventually the trace gives me an error like this: INFO: Parsing Manifest File C:\wwapps\Conf\SideBySide\Code\app.EXE.     INFO: Manifest Definition Identity is App.exe,processorArchitecture="x86",type="win32",version="1.0.0.0".     ERROR: Line 13: The value {AAaf2c2811-0657-4264-a1f5-06d033a969ff} of attribute clsid in element comClass is invalid. ERROR: Activation Context generation failed. End Activation Context Generation. pinpointing nicely where the error lies. Pay special attention to the various attributes - they have to match exactly in the different sections of the manifest file(s). Multiple COM Objects The manifest file that Visual Studio creates is actually quite more complex than is required for basic registrationless COM object invokation. The manifest file can be simplified a lot actually by stripping off various namespaces and removing the type library references altogether. Here's an example of a simplified manifest file that actually includes references to 2 COM servers: xml version="1.0" encoding="utf-8"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name = "sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" threadingModel="apartment" / file assembly Simple enough right? Routing to separate Manifest Files and Folders In the examples above all files ended up in the application's root folder - all the DLLs, support files and runtimes. Sometimes that's not so desirable and you can actually create separate manifest files. The easiest way to do this is to create a manifest file that 'routes' to another manifest file in a separate folder. Basically you create a new 'assembly identity' via a named id. You can then create a folder and another manifest with the id plus .manifest that points at the actual file. In this example I create: App.exe.manifest A folder called App.deploy A manifest file in App.deploy All DLLs and runtimes in App.deploy Let's start with that master manifest file. This file only holds a reference to another manifest file: App.exe.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / dependency dependentAssembly assemblyIdentity name="App.deploy" version="1.0.0.0" type="win32" / dependentAssembly dependency assembly   Note this file only contains a dependency to App.deploy which is another manifest id. I can then create App.deploy.manifest in the current folder or in an App.deploy folder. In this case I'll create App.deploy and in it copy the DLLs and support runtimes. I then create App.deploy.manifest. App.deploy.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.deploy" type="win32" version="1.0.0.0" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name="sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" threadingModel="Apartment" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" / file assembly   In this manifest file I then host my COM DLLs and any support runtimes. This is quite useful if you have lots of DLLs you are referencing or if you need to have separate configuration and application files that are associated with the COM object. This way the operation of your main application and the COM objects it interacts with is somewhat separated. You can see the two folders here:   Routing Manifests to different Folders In theory registrationless COM should be pretty easy in painless - you've seen the configuration manifest files and it certainly doesn't look very complicated, right? But the devil's in the details. The ActivationContext API (SxS - side by side activation) is very intolerant of small errors in the XML or formatting of the keys, so be really careful when setting up components, especially if you are manually editing these files. If you do run into trouble SxsTrace/SxsParse are a huge help to track down the problems. And remember that if you do have problems that you'll need to recompile your EXEs or DLLs for the SxS APIs to refresh themselves properly. All of this gets even more fun if you want to do registrationless COM inside of IIS :-) But I'll leave that for another blog post…© Rick Strahl, West Wind Technologies, 2005-2011Posted in COM  .NET  FoxPro   Tweet (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

  • Perforce: File tampered with after resolve - edit or revert

    - by fbrereto
    I'm doing an integration in Perforce and am being met with the following: p4 integrate -1 -d -i -t -r -b my_branchspec //Foo/file.txt#6 - integrate from //Bar/file.txt#6 p4 resolve -am /Foo/file.txt - merging //Bar/file.txt#6 /Foo/file.txt tampered with before resolve - edit or revert. It seems no matter what I do, I am unable to make this issue go away: the next forward integration will show a similar message. The file is a text file. I can confirm that the MD5 hash for both files before the integration takes place is the same. What other issues might be going on with this file that I can resolve to fix this nagging message?

    Read the article

  • Force RAID to read "exiled" disk?

    - by user197015
    We have a RAID 6 array (Infortrend EonStor DS S16F) that recently had two disks fail. Immediately prior to replacing these two disks, a third, good, disk was accidentally ejected from the array. After reinserting this disk it is marked as "exiled" by the array's firmware, and so even after replacing the two failed disks with new ones the array refuses to rebuild the logical volume and remains inaccessible. Since the temporarily-ejected disk is still functional and nothing has been written to the array since it was ejected, it seems that it should theoretically be possible to recover all the data on the array, but how can we convince the array to use the data from the "exiled" disk? Thanks for any help or advice you can offer.

    Read the article

  • opendkim reporting read private key failed: no start line

    - by Bob
    I've set up keys with the following: opendkim-genkey -t -s mail -d test.com The private key (pertinent to this question) contains: -----BEGIN RSA PRIVATE KEY----- (some stuff here) -----END RSA PRIVATE KEY----- My opendkim.conf contains: Domain test.com KeyFile /etc/opendkim/dkim.private Selector mail I am then testing with: opendkim-testkey -d test.com -s mail -k /etc/mail/dkim.public Yet receive the following error: opendkim-testkey: PEM_read_bio_PrivateKey() failed error:0906D06C:PEM routines:PEM_read_bio:no start line The files exist and have opendkim as the user and group, and adequate permissions. Has anyone any advice?

    Read the article

  • Problem with XLSX file on Office 2003 with Compatibility Pack

    - by MadBoy
    I've this machine which has Office 2003 installed with Compatibility Pack. User received one file which she has to work with in XLSX format (file has to stay in that format so options to save it as XLS can be skipped). When she opens the file from Desktop or any other location it gives an error like "Cannot find the file in following location" and in the background it starts Converting XLSX file to XLS. In the end Excel is opened up with some random file name X000008.xls (Read Only) which is just 1 to 1 conversion of the XLSX document. However if I go directly to Excel and use File / Open and try to open the XLSX file no error or conversion is done. The file is writable and can be saved in XLSX format. The file name is simple like This_file something.XLSX, I've even tried to remove all spaces but it gave no better results. Anyone has any recommendations? So far I have done: 1. Uninstalled Compatibility Pack and installed it again. Tried opening it without any other updates and the error still pops out. In progress: I am now running all possible updates of office (like 5 of them) which i suppos won't fix anything (as they were applied when I've uninstalled compatibility pack). Next in run will be (not yet done) installing Windows XP SP3. What other things I can do?

    Read the article

  • Exchange migration to 2007 making Outlook 2003 unable to read meeting requests

    - by Kvad
    Hi, We are currently moving from Exchange 2003 to 2007 (8.2 build 176.2). We have encounted an issue with one user. In Outlook 2003 when getting a meeting request: "Can't open this item. Could not complete the operation. One or more parameter values are nto valid." The item cannot be previewed in the reading pane either. The item can be viewed in OWA and iPhone fine. I've tried with cache mode off and on. Different computers. Same issue. There are the following entries on the account: SMTP [email protected] [email protected] X400 C=AU;A= ;P=Company Name;O=Exchange;S=LastName;G=FirstName; I'm loathe to recreate the account. This will be an extreme last resort. Any ideas? Thanks in advance.

    Read the article

  • SQL Server 2008 - "Enhanced read-ahead and scan"?

    - by Chris J
    Hi all, Can anyone point me to, or does anyone know what this "feature" of SQL Server is? Googling for it (also for "Super scan" which seems to be a synonym for the feature) reveals no information other than all the edition comparison pages that exist out there for SQL Server. I'm also not sure whether this is a stackoverflow or a serverfault question. I'll try here on serverfault first, but if folk think stackoverflow may be a better forum, drop me a comment to that effect - ta :-)

    Read the article

  • Cannot read/write FTP directory vsftpd on centos 6.0 (empty folder)

    - by adrianTNT
    I have Centos 6.0 and installed vsftp with YUM, I added a user with Webmin panel, set its home dir to "/var/www/html" and its shell to "/bin/sh", user id is 500, user group is same as name: "adrian_ftp". When I start a ftp program it logs in but the remote folder always shows empty. I set directory owner and group to adrian_ftp:adrian_ftp , no change, I also made them 0777, no change. Any ideas? I tried for over 3-4 hours :|

    Read the article

  • How to read Mac floppy on a PC?

    - by Robot
    I have a floppy made on a Mac years ago. I'd like to pull some files from it, but Macs haven't had floppies in forever, so I don't have one. I tried an app called MacOpener, but it didn't seem to work, plus it was pretty old. I even tried sharing the PC's A:\ drive and accessing it remotely from a Mac, but that didn't work either. Any ideas?

    Read the article

< Previous Page | 125 126 127 128 129 130 131 132 133 134 135 136  | Next Page >