Search Results

Search found 3463 results on 139 pages for 'physical'.

Page 129/139 | < Previous Page | 125 126 127 128 129 130 131 132 133 134 135 136  | Next Page >

  • Active Directory Time Synchronisation - Time-Service Event ID 50

    - by George
    I have an Active Directory domain with two DCs. The first DC in the forest/domain is Server 2012, the second is 2008 R2. The first DC holds the PDC Emulator role. I sporadically receive a warning from the Time-Service source, event ID 50: The time service detected a time difference of greater than %1 milliseconds for %2 seconds. The time difference might be caused by synchronization with low-accuracy time sources or by suboptimal network conditions. The time service is no longer synchronized and cannot provide the time to other clients or update the system clock. When a valid time stamp is received from a time service provider, the time service will correct itself. Time sync in the domain is configured with the second DC to synchronise using the /syncfromflags:DOMHIER flag. The first DC is configured to sync time using a /syncfromflags:MANUAL /reliable:YES, from a peerlist consisting of a number of UK based stratum 2 servers, such as ntp2d.mcc.ac.uk. I'm confused why I receive this event warning. It implies that my PDC emulator cannot synchronise time with a supposedly reliable external time source, and it quotes a time difference of 5 seconds for 900 seconds. It's worth also mentioning that I used to use a UK pool from ntp.org but I would receive the warning much more often. Since updating to a number of UK based academic time servers, it seems to be more reliable. Can someone with more experience shed some light on this - perhaps it is purely transient? Should I disregard the warning? Is my configuration sound? EDIT: I should add that the DCs are virtual, and installed on two separate VMware ESXi/vSphere physical hosts. I can also confirm that as per MDMarra's comment and best practice, VMware timesync is disabled, since: c:\Program Files\VMware\VMware Tools\VMwareToolboxCmd.exe timesync status returns Disabled. EDIT 2 Some strange new issue has cropped up. I've noticed a pattern. Originally, the event ID 50 warnings would occur at about 1230pm each day. This is interesting since our veeam backup happens at 12 midday. Since I made the changes discussed here, I now receive an event ID 51 instead of 50. The new warning says that: The time sample received from peer server.ac.uk differs from the local time by -40 seconds (Or approximately 40 seconds). This has happened two days in a row. Now I'm even more confused. Obviously the time never updates until I manually intervene. The issue seems to be related to virtualisation and veeam. Something may be occuring when veeam is backing up the PDCe. Any suggestions? UPDATE & SUMMARY msemack's excellent list of resources below (the accepted answer) provided enough information to correctly configure the time service in the domain. This should be the first port of call for any future people looking to verify their configuration. The final "40 second jump" issue I have resolved (there are no more warnings) through adjusting the VMware time sync settings as noted in the veeam knowledge base article here: http://www.veeam.com/kb1202 In any case, should any future reader use ESXi, veeam or not, the resources here are an excellent source of information on the time sync topic and msemack's answer is particularly invaluable.

    Read the article

  • NIC Bonding/balance-rr with Dell PowerConnect 5324

    - by Branden Martin
    I'm trying to get NIC bonding to work with balance-rr so that three NIC ports are combined, so that instead of getting 1 Gbps we get 3 Gbps. We are doing this on two servers connected to the same switch. However, we're only getting the speed of one physical link. We are using 1 Dell PowerConnect 5324, SW version 2.0.1.3, Boot version 1.0.2.02, HW version 00.00.02. Both servers are CentOS 5.9 (Final) running OnApp Hypervisor (CloudBoot) Server 1 is using ports g5-g7 in port-channel 1. Server 2 is using ports g9-g11 in port-channel 2. Switch show interface status Port Type Duplex Speed Neg ctrl State Pressure Mode -------- ------------ ------ ----- -------- ---- ----------- -------- ------- g1 1G-Copper -- -- -- -- Down -- -- g2 1G-Copper Full 1000 Enabled Off Up Disabled Off g3 1G-Copper -- -- -- -- Down -- -- g4 1G-Copper -- -- -- -- Down -- -- g5 1G-Copper Full 1000 Enabled Off Up Disabled Off g6 1G-Copper Full 1000 Enabled Off Up Disabled Off g7 1G-Copper Full 1000 Enabled Off Up Disabled On g8 1G-Copper Full 1000 Enabled Off Up Disabled Off g9 1G-Copper Full 1000 Enabled Off Up Disabled On g10 1G-Copper Full 1000 Enabled Off Up Disabled On g11 1G-Copper Full 1000 Enabled Off Up Disabled Off g12 1G-Copper Full 1000 Enabled Off Up Disabled On g13 1G-Copper -- -- -- -- Down -- -- g14 1G-Copper -- -- -- -- Down -- -- g15 1G-Copper -- -- -- -- Down -- -- g16 1G-Copper -- -- -- -- Down -- -- g17 1G-Copper -- -- -- -- Down -- -- g18 1G-Copper -- -- -- -- Down -- -- g19 1G-Copper -- -- -- -- Down -- -- g20 1G-Copper -- -- -- -- Down -- -- g21 1G-Combo-C -- -- -- -- Down -- -- g22 1G-Combo-C -- -- -- -- Down -- -- g23 1G-Combo-C -- -- -- -- Down -- -- g24 1G-Combo-C Full 100 Enabled Off Up Disabled On Flow Link Ch Type Duplex Speed Neg control State -------- ------- ------ ----- -------- ------- ----------- ch1 1G Full 1000 Enabled Off Up ch2 1G Full 1000 Enabled Off Up ch3 -- -- -- -- -- Not Present ch4 -- -- -- -- -- Not Present ch5 -- -- -- -- -- Not Present ch6 -- -- -- -- -- Not Present ch7 -- -- -- -- -- Not Present ch8 -- -- -- -- -- Not Present Server 1: cat /etc/sysconfig/network-scripts/ifcfg-eth3 DEVICE=eth3 HWADDR=00:1b:21:ac:d5:55 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth4 DEVICE=eth4 HWADDR=68:05:ca:18:28:ae USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth5 DEVICE=eth5 HWADDR=68:05:ca:18:28:af USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-onappstorebond DEVICE=onappstorebond IPADDR=10.200.52.1 NETMASK=255.255.0.0 GATEWAY=10.200.2.254 NETWORK=10.200.0.0 USERCTL=no BOOTPROTO=none ONBOOT=yes cat /proc/net/bonding/onappstorebond Ethernet Channel Bonding Driver: v3.4.0-1 (October 7, 2008) Bonding Mode: load balancing (round-robin) MII Status: up MII Polling Interval (ms): 100 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth3 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 00:1b:21:ac:d5:55 Slave Interface: eth4 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:28:ae Slave Interface: eth5 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:28:af Server 2: cat /etc/sysconfig/network-scripts/ifcfg-eth3 DEVICE=eth3 HWADDR=00:1b:21:ac:d5:a7 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth4 DEVICE=eth4 HWADDR=68:05:ca:18:30:30 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth5 DEVICE=eth5 HWADDR=68:05:ca:18:30:31 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-onappstorebond DEVICE=onappstorebond IPADDR=10.200.53.1 NETMASK=255.255.0.0 GATEWAY=10.200.3.254 NETWORK=10.200.0.0 USERCTL=no BOOTPROTO=none ONBOOT=yes cat /proc/net/bonding/onappstorebond Ethernet Channel Bonding Driver: v3.4.0-1 (October 7, 2008) Bonding Mode: load balancing (round-robin) MII Status: up MII Polling Interval (ms): 100 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth3 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 00:1b:21:ac:d5:a7 Slave Interface: eth4 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:30:30 Slave Interface: eth5 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:30:31 Here are the results of iperf. ------------------------------------------------------------ Client connecting to 10.200.52.1, TCP port 5001 TCP window size: 27.7 KByte (default) ------------------------------------------------------------ [ 3] local 10.200.3.254 port 53766 connected with 10.200.52.1 port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 950 MBytes 794 Mbits/sec

    Read the article

  • WDS DHCP same server on Windows Server 2008

    - by Richard
    I have been struggling with a problem on my Windows Server 2008 for the past 4 - 5 hours and cannot figure out whats wrong. I have tried pretty much everything that I found on google and all the links are purple. Hopefully you guys can help me. I am running a Windows Server 2008 Standard edition with the latest updates as of today. Furthermore I am running a Windows Server 2003. Both are virtual machines on my ESXi 5 server. My network is: 192.168.10.0/24 W2k8: 192.168.10.251 is the PDC running ADS, DHCP and WDS W2k3: 192.168.10.253 AND 192.168.1.175 running Routing and Remote Access and ISA 2006 Enterprise In my internal network (192.168.10.0/24) I have my client machine (192.168.10.10) that runs a VMWare Workstation. I am trying to deploy Windows 7 Home Premium to a virtual machine on my VMWorkstation via PXE. I have set the Workstation's VM network adapter to "bridged" so that it uses the physical network adapter and is connected to my internal network. The DHCP pool is configured to give IP addresses from 192.168.10.10-192.168.10.15 (works for normal clients and is not used up) When I start my VM with the PXE I get the error: PXE-E52:proxyDHCP offers were received. No DHCP offers were received Apperently this means "that means that WDS responded but the DHCP server did not." People suggested to direct the traffic to both WDS and DHCP on the router, since everything is on the same subnet there is no need for that as the broadcast is seen by everyone (WDS and DHCP) No reservation for the virtual mac addrs is made on the DHCP. Furthermore it was suggested to configure the DHCP options: Option 60= PXEClient Option 66= WDS server name or IP address Option 67= Boot file name However, this is not recommended by Microsoft, I tried it and it did not solve my problem. The configuration on the WDS (My System is German therefore the actual naming might be different): PXE response tab: PXE responses is set to "ALL (known and unknown)" DHCP Tab: Do not listen to port 67 is NOT ticked - if I tick this I do not get any responses and the PXE errors gets PXE-E51 that neither DHCP or proxyDHCP were received DHCP-Option 60 for "PXEClient" is ticked The confusing part here is that it is advised in the tab to tick the first option since it is on the same server. Network Configuration Tab: Use the following IP-Address range for Multicast-IP-Address: 224.0.1.0 - 224.0.10.0 Thats not the default one, however it is in the allowed range. The UDP port range is the default since it is not advised to change them. I tried to change the "networkprofile" from 100mbits/1gbits and custom. I am running a 1gbit network with CAT6 cables and 1gbit netgear switch 5 ports. Everything is configured to use 1gbit. The WDS is authorised for the DHCP server. My ISA 2006 configuration: For the internal networking i have configured the following policy array: Allow protocols on internal network including the w2k3 host: 67,68,53,ICMP, 4011 UDP receive, 64001-6500 UDP send receive, 69 UDP send Routing and Remote Access I tried the DHCP relay agent configuration that was suggested as well, but that did not work I would highly appreciate anykind of help because I am pretty much done here with my nerves. Thank you very much in advance.

    Read the article

  • reiserfsck on lvm

    - by DaDaDom
    It seems like my filesystem got corrupted somehow during the last reboot of my server. I can't fsck some logical volumes anymore. The setup: root@rescue ~ # cat /mnt/rescue/etc/fstab proc /proc proc defaults 0 0 /dev/md0 /boot ext3 defaults 0 2 /dev/md1 / ext3 defaults,errors=remount-ro 0 1 /dev/systemlvm/home /home reiserfs defaults 0 0 /dev/systemlvm/usr /usr reiserfs defaults 0 0 /dev/systemlvm/var /var reiserfs defaults 0 0 /dev/systemlvm/tmp /tmp reiserfs noexec,nosuid 0 2 /dev/sda5 none swap defaults,pri=1 0 0 /dev/sdb5 none swap defaults,pri=1 0 0 [UPDATE] First question: what "part" should I check for bad blocks? The logical volume, the underlying /dev/md or the /dev/sdx below that? Is doing what I am doing the right way to go? [/UPDATE] The errormessage when checking /dev/systemlvm/usr: root@rescue ~ # reiserfsck /dev/systemlvm/usr reiserfsck 3.6.19 (2003 www.namesys.com) [...] Will read-only check consistency of the filesystem on /dev/systemlvm/usr Will put log info to 'stdout' Do you want to run this program?[N/Yes] (note need to type Yes if you do):Yes ########### reiserfsck --check started at Wed Feb 3 07:10:55 2010 ########### Replaying journal.. Reiserfs journal '/dev/systemlvm/usr' in blocks [18..8211]: 0 transactions replayed Checking internal tree.. Bad root block 0. (--rebuild-tree did not complete) Aborted Well so far, let's try --rebuild-tree: root@rescue ~ # reiserfsck --rebuild-tree /dev/systemlvm/usr reiserfsck 3.6.19 (2003 www.namesys.com) [...] Will rebuild the filesystem (/dev/systemlvm/usr) tree Will put log info to 'stdout' Do you want to run this program?[N/Yes] (note need to type Yes if you do):Yes Replaying journal.. Reiserfs journal '/dev/systemlvm/usr' in blocks [18..8211]: 0 transactions replayed ########### reiserfsck --rebuild-tree started at Wed Feb 3 07:12:27 2010 ########### Pass 0: ####### Pass 0 ####### Loading on-disk bitmap .. ok, 269716 blocks marked used Skipping 8250 blocks (super block, journal, bitmaps) 261466 blocks will be read 0%....20%....40%....60%....80%....100% left 0, 11368 /sec 52919 directory entries were hashed with "r5" hash. "r5" hash is selected Flushing..finished Read blocks (but not data blocks) 261466 Leaves among those 13086 Objectids found 53697 Pass 1 (will try to insert 13086 leaves): ####### Pass 1 ####### Looking for allocable blocks .. finished 0% left 12675, 0 /sec The problem has occurred looks like a hardware problem (perhaps memory). Send us the bug report only if the second run dies at the same place with the same block number. mark_block_used: (39508) used already Aborted Bad. But let's do it again as mentioned: [...] Flushing..finished Read blocks (but not data blocks) 261466 Leaves among those 13085 Objectids found 54305 Pass 1 (will try to insert 13085 leaves): ####### Pass 1 ####### Looking for allocable blocks .. finished 0%... left 12127, 958 /sec The problem has occurred looks like a hardware problem (perhaps memory). Send us the bug report only if the second run dies at the same place with the same block number. build_the_tree: Nothing but leaves are expected. Block 196736 - internal Aborted Same happens every time, only the actual error message changes. Sometimes I get mark_block_used: (somenumber) used already, other times the block number changes. Seems like something is REALLY broken. Are there any chances I can somehow get the partitions to work again? It's a server to which I don't have physical access directly (hosted server). Thanks in advance!

    Read the article

  • Magento hosting on a budget

    - by spa
    I have to do a setup for Magento. My constraint is primarily ease of setup and fault tolerance/fail over. Furthermore costs are an issue. I have three identical physical servers to get the job done. Each server node has an i7 quad core, 16GB RAM, and 2x3TB HD in a software RAID 1 configuration. Each node runs Ubuntu 12.04. right now. I have an additional IP address which can be routed to any of these nodes. The Magento shop has max. 1000 products, 50% of it are bundle products. I would estimate that max. 100 users are active at once. This leads me to the conclusion, that performance is not top priority here. My first setup idea One node (lb) runs nginx as a load balancer. The additional IP is used with domain name and routed to this node by default. Nginx distributes the load equally to the other two nodes (shop1, shop2). Shop1 and shop2 are configured equally: each server runs Apache2 and MySQL. The Mysqls are configured with master/slave replication. My failover strategy: Lb fails = Route IP to shop1 (MySQL master), continue. Shop1 fails = Lb will handle that automatically, promote MySQL slave on shop2 to master, reconfigure Magento to use shop2 for writes, continue. Shop2 fails = Lb will handle that automatically, continue. Is this a sane strategy? Has anyone done a similar setup with Magento? My second setup idea Another way to do it would be to use drbd for storing the MySQL data files on shop1 and shop2. I understand that in this scenario only one node/MySQL instance can be active and the other is used as hot standby. So in case shop1 fails, I would start up MySQL on shop2, route the IP to shop2, and continue. I like that as the MySQL setup is easier and the nodes can be configured 99% identical. So in this case the load balancer becomes useless and I have a spare server. My third setup idea The third way might be master-master replication of MySQL databases. However, in my optinion this might be tricky, as Magento isn't build for this scenario (e.g. conflicting ids for new rows). I would not do that until I have heard of a working example. Could you give me an advice which route to follow? There seems not one "good" way to do it. E.g. I read blog posts which describe a MySQL master/slave setup for Magento, but elsewhere I read, that data might get duplicated when the slave lags behind the master (e.g. when an order is placed, a customer might get created twice). I'm kind of lost here.

    Read the article

  • Performing mechanical movements using computer

    - by Vi
    How to make a computer (in particular, my laptop) to perform some mechanical movements without buying anything $5, soldering things inside computer or creating big sophisticated circuits? Traditionally CD-ROM tray is used to make computer do some movement IRL by, for example, SSH command, but in laptop tray is one-shot (unless manually reloaded) and also not very comfortable [mis]usage. Some assistance circuits can be in use too, but not complex. For example, there is a little motor that can work on USB power. Devices in my computer: DVD-ROM tray: one-time push. USB power: continuous power to the motor or LEDS or relay that turns on something powerful. Audio card. 3 outputs (modprobe alsa model=test can set Mic and Line-in as additional output). One controllable DC output (microphone) that can power up LED and some electronic (may be even mechanic?) relay. Also with sophisticated additional circuiting can control a lot of devices with a good precision. Both input and output support. Probably the most useful object in computer for radio ham. Modem. Don't know about this much, it doesn't work because of hsfmodem crashes kernel if memory is = 1GB. May be it's "pick up" and "hang up" can turn on and off power taken from USB port? Video card. VGA port? S-Video port? Will them be useful? Backlight. Tunable, but probably unuseful. CardBus (or some) slot. Nothing interesting for the task probably (is it?). AC adapter and battery. Probably nothing programmable here. /* My AC adapter already have additional jacks to connect extra devics */ Keyboard. No use. Touchpad. Good sensor (synclient -m 1), but no output. Various LEDs inside laptop. Probably too weak and requires soldering. Fans inside laptop. Poor control over them, requires soldering and dangerous to tinker. HDD (internal and external) that can be spin down and up (hdparm -Y, cat /dev/ubb). But connecting anything serially with it's power line makes HDD underpowered... And too complex. Is something are missed? Any ideas how to use described components? Any other ideas? May be there are easily available /* in developing countries */ cheap devices like "enhanced multimeters" that are controllable from computer and can provide configurable output and measure current and other things? Things to aid pushing many physical buttons with computer. Isn't this a simple idea and implementation and a lot of use in good hands?

    Read the article

  • IBM Server Config questions

    - by Joel Coel
    I have a few questions on a potential server setup. First, the situation: Last year we bought an IBM x3500 server with 2 Xeon E5410's, 9GB RAM, 6 HDDs. The original intent for this server was to replace the old exchange e-mail server. It was brought in, set up, and then shortly after we switched to gmail. Shortly after that my predecessor left for greener pastures, and finally I was hired. So this nice server is now sitting (mostly) idle. This year I have budget again for one server, and of course I want to put this other server to work. I'm thinking about the best use for the two server, and I think I finally have a plan for what I want to do with them. The idea is to use the two newer servers as a pair of VM hosts. I will set up each server with the same 8 VMs, but divide up the load so that only 4 are active per physical host. That means I've normally got 2GB RAM + 2 cores per host. I've done some load testing to pick out what servers to convert to virtual, and chose them so that each host will be capable of handling the entire set of 8 by itself in a pinch with 1 core and 1GB RAM, but would be very taxed to do so. This should take our data center from 13 total servers down to 7. The "servers" I'm replacing are mostly re-purposed desktops, so I'm more than happy to be able to do this. Now it's time to go shopping for the new server. I'd like my two hosts to match as closely as possible, and so I'm looking at IBM again. It also helps that we have some educational matching grant money from IBM that I need to use to help pay for this system (we're a small private college). So finally, (if you're not bored already), we come to my questions: Am I missing anything big or obvious in this plan? I'm a little worried about network performance since the VM hosts will only have 4 nics total where 8 used to be, but I don't think it will be a problem. Is there anything else like this I might be overlooking? Am I making it even too complicated? IBM no longer has a good analog to last year's server. If I want to match the performance (8 cores, 9GB RAM, 1333mhz front side bus, 6 spindles), I have to spend quite a bit more than we paid last year: $2K+, or nearly a 33% cost increase. This only brings a marginal increase in performance. The alternative to stay in budget is to take a hit on the fsb down to 800mhz or cut the number of cores in half, neither of which is attractive. The main cost culprit is the processor. IBM no longer offers the E5410. It's listed as a part, but not available in any of the server configs I've looked at. I'm considering getting the cheapest 800mhz fsb dual core xeon I can configure and then buying the E5410's separately. That's still an extra $350 I wasn't counting on, but that's better than $2K. I want to know what others think of this - will it work or will I end up with the wrong motherboard or some other issue? Am I missing a simple way to configure the server I really want? I don't really intend to do this, but one option to save some money back is to omit the redundant power supply. Since my redundancy plan for these system is to switch over to a completely different host, the extra power isn't fully necessary. That said, it's still very helpful to avoid even short downtimes while I switch over VMs. Has anyone done this?

    Read the article

  • MySQL Memory usage

    - by Rob Stevenson-Leggett
    Our MySQL server seems to be using a lot of memory. I've tried looking for slow queries and queries with no index and have halved the peak CPU usage and Apache memory usage but the MySQL memory stays constantly at 2.2GB (~51% of available memory on the server). Here's the graph from Plesk. Running top in the SSH window shows the same figures. Does anyone have any ideas on why the memory usage is constant like this and not peaks and troughs with usage of the app? Here's the output of the MySQL Tuning Primer script: -- MYSQL PERFORMANCE TUNING PRIMER -- - By: Matthew Montgomery - MySQL Version 5.0.77-log x86_64 Uptime = 1 days 14 hrs 4 min 21 sec Avg. qps = 22 Total Questions = 3059456 Threads Connected = 13 Warning: Server has not been running for at least 48hrs. It may not be safe to use these recommendations To find out more information on how each of these runtime variables effects performance visit: http://dev.mysql.com/doc/refman/5.0/en/server-system-variables.html Visit http://www.mysql.com/products/enterprise/advisors.html for info about MySQL's Enterprise Monitoring and Advisory Service SLOW QUERIES The slow query log is enabled. Current long_query_time = 1 sec. You have 6 out of 3059477 that take longer than 1 sec. to complete Your long_query_time seems to be fine BINARY UPDATE LOG The binary update log is NOT enabled. You will not be able to do point in time recovery See http://dev.mysql.com/doc/refman/5.0/en/point-in-time-recovery.html WORKER THREADS Current thread_cache_size = 0 Current threads_cached = 0 Current threads_per_sec = 2 Historic threads_per_sec = 0 Threads created per/sec are overrunning threads cached You should raise thread_cache_size MAX CONNECTIONS Current max_connections = 100 Current threads_connected = 14 Historic max_used_connections = 20 The number of used connections is 20% of the configured maximum. Your max_connections variable seems to be fine. INNODB STATUS Current InnoDB index space = 6 M Current InnoDB data space = 18 M Current InnoDB buffer pool free = 0 % Current innodb_buffer_pool_size = 8 M Depending on how much space your innodb indexes take up it may be safe to increase this value to up to 2 / 3 of total system memory MEMORY USAGE Max Memory Ever Allocated : 2.07 G Configured Max Per-thread Buffers : 274 M Configured Max Global Buffers : 2.01 G Configured Max Memory Limit : 2.28 G Physical Memory : 3.84 G Max memory limit seem to be within acceptable norms KEY BUFFER Current MyISAM index space = 4 M Current key_buffer_size = 7 M Key cache miss rate is 1 : 40 Key buffer free ratio = 81 % Your key_buffer_size seems to be fine QUERY CACHE Query cache is supported but not enabled Perhaps you should set the query_cache_size SORT OPERATIONS Current sort_buffer_size = 2 M Current read_rnd_buffer_size = 256 K Sort buffer seems to be fine JOINS Current join_buffer_size = 132.00 K You have had 16 queries where a join could not use an index properly You should enable "log-queries-not-using-indexes" Then look for non indexed joins in the slow query log. If you are unable to optimize your queries you may want to increase your join_buffer_size to accommodate larger joins in one pass. Note! This script will still suggest raising the join_buffer_size when ANY joins not using indexes are found. OPEN FILES LIMIT Current open_files_limit = 1024 files The open_files_limit should typically be set to at least 2x-3x that of table_cache if you have heavy MyISAM usage. Your open_files_limit value seems to be fine TABLE CACHE Current table_cache value = 64 tables You have a total of 426 tables You have 64 open tables. Current table_cache hit rate is 1% , while 100% of your table cache is in use You should probably increase your table_cache TEMP TABLES Current max_heap_table_size = 16 M Current tmp_table_size = 32 M Of 15134 temp tables, 9% were created on disk Effective in-memory tmp_table_size is limited to max_heap_table_size. Created disk tmp tables ratio seems fine TABLE SCANS Current read_buffer_size = 128 K Current table scan ratio = 2915 : 1 read_buffer_size seems to be fine TABLE LOCKING Current Lock Wait ratio = 1 : 142213 Your table locking seems to be fine The app is a facebook game with about 50-100 concurrent users. Thanks, Rob

    Read the article

  • opennms postgres connection slow

    - by krisdigitx
    i am running the opennms application server on a physical server and the database on an ESXi VM. Recently the opennms webconsole has been very slow to load as such i deleted most of the events from the database table, now both servers have no load at all, and the psql connection from the application server to the database server is also very fast, but somehow opennms webconsole is still slow. this is the strace from the opennms process id: 18629 futex(0x2aaac77d8a84, FUTEX_WAIT_PRIVATE, 453, NULL <unfinished ...> 3015 futex(0x2aaabc4a2ee4, FUTEX_WAIT_PRIVATE, 323, NULL <unfinished ...> 10863 futex(0x2aaabbebaa94, FUTEX_WAIT_PRIVATE, 395, NULL <unfinished ...> 25260 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 10859 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 10982 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 3011 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 25260 futex(0x2aaae098fc28, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 10982 futex(0x2aaac0eaf928, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 3011 futex(0x2aaab0cb1728, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 10859 futex(0x2aaac062c328, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 25260 <... futex resumed> ) = 0 10982 <... futex resumed> ) = 0 3011 <... futex resumed> ) = 0 10859 <... futex resumed> ) = 0 25260 futex(0x2aaabc38b6b4, FUTEX_WAIT_PRIVATE, 443, NULL <unfinished ...> 10982 futex(0x2aaabc5d7b94, FUTEX_WAIT_PRIVATE, 99, NULL <unfinished ...> 3011 futex(0x2aaac7c55334, FUTEX_WAIT_PRIVATE, 183, NULL <unfinished ...> 10859 futex(0x2aaabbb8c9d4, FUTEX_WAIT_PRIVATE, 347, NULL <unfinished ...> 10846 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 10846 futex(0x2aaae9022428, FUTEX_WAKE_PRIVATE, 1) = 0 10846 futex(0x2aaabe0030b4, FUTEX_WAIT_PRIVATE, 251, NULL <unfinished ...> 20281 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 14100 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 2925 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 10843 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 20281 futex(0x2aaac7e93628, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 14100 futex(0x2aaac04e8c28, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 2925 futex(0x2aaaec085528, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 10843 futex(0x2aaab20b0528, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> and shows lots of connection timeout??? i think its the connection between the java application and database which is causing issues. any ideas how to troubleshoot this???

    Read the article

  • Intel Rapid Storage / Smart Response SSD caching issue

    - by goober
    Background Recently built my own PC. It works! Almost. It's been a while since getting into the guts of these things, so I'm familiar but may be missing something simple. FYI, I don't care about blowing the OS away -- it's brand new and we can go back from scratch as many times as necessary. Goal / Issue I'd like to use the SSD to take advantage of Intel's Smart Response technology (allows the SSD to act as a cache for HDDs) I would like the SSD cache to act as a cache for my HDDs, which I would like to be in a RAID1 array (so I get the speed from the SSD and the redundancy from the RAID1) However, Windows only sees the drive in device manager (not as a drive), so I'm unsure what to do about that. Related: as far as I know, for this to work, the drives all have to be in a single RAID array (i.e. a RAID0 pairing of the SSD and the RAID1 HDD array). However, when attempting this at the BIOS level, I am told there is not enough space for an array. Steps so Far Moved the SSD onto the Intel controller (I'd had it on the Marvel 6.0 controller instead of the Intel controller, so the BIOS was only seeing it in a strange way) Updated the BIOS of the motherboard to the latest version Reinstalled Intel's RST (iRST?) software several times, as some forums reported it working after reinstalling 3 times (which does not inspire confidence). Checked Intel storage: it does see the SSD as a physical, non-RAID device. However, it says no space exists if I try to create an array. Checked the BIOS: it does not show up in the boot order, but is an option that can be selected under boot options. Tried the firmware update for that model. Issue: the firmware CD doesn't detect a drive; maybe the Intel storage controller is making it difficult? moved the ssd to the marvel controller. The firmware update cd appeared to hang while searching for drives. swapped out the SATA cable for the manufacturer's and moved back to the intel storage controller. Noticed at this point that in the Intel RST software, a device DOES show up in addition to the RAID set -- only shown as a "60 GB internal disk". Windows doesn't appear to see it as a drive, but it does still show in device manager. Move SSD to port from 0-3 on MOBO and set SATA mode to IDE (after disconnecting RAID1 config) to allow the firmware update to work. Firmware was already at the latest version. Next Steps ? Components involved ASUS P8Z68-V PRO motherboard (Intel Z68 Chipset) Intel i7 2600k Processor 2 x 1TB 7200 RPM HDDs 64 GB Crucial M4 SSD (M4-CT064M4SSD2) For Reference -- Storage Configuration Intel 3 gbps Intel 3gbps Intel 6gbps Marvel 6gbps +----------+ +----------+ +----------+ +----------+ | | <----+ | | +-+ | | | |----------| | |----------| |-|--------| |----------| | | | | + | | | | | | +----------+ | +--|-------+ +-|--------+ +----------+ | | | + v v | 1 TB HDD 64 GB SSD + +> 1 TB HDD For Reference -- Intel RST (v10.8.0.1003) Screenshot Don't mind the "rebuilding" -- knocked a power cable out at one point; it's doing its job, not an indicator of a bad HDD. Any thoughts? Thanks in advance for any help!

    Read the article

  • moving raid 10 to another identical server both on Smart Array 6i controllers

    - by SalimQrdl
    I have dead HP DL 380G4 with RAID 1+0 with 1 logical volume from 4x72GB drives on built-in Smart Array 6i 128Mb BBWC. It was shut down properly. It seems it was usual death for Proliant with ILO led 2,3,8 lighting. I want to move array to another identical server with same raid firmware level. What is the best strategy?: I have RAID 1+0 on bay 0 bay 1 bay 2 bay 3 As I understand bay0+bay1 are in RAID 1 , bay2+bay3 are in RAID 1, and both RAID 1 pairs are in RAID 0. So should I : Clear RAID config on new server, insert bay 0, bay 2 and power-on or Create RAID 1+0 with 1 logical volume from clear HDDs , and then poweroff ,remove HDDs and insert 2 HDDs(bay 0, bay 2) from old RAID 1+0. then power-on. (each hdd has its raid position info stored but may be could work on same config) According to documentation for Smart Array 6i it could be possible to migrate. however one requirement point is unclear for me Before you move drives, the following conditions must be met: • The array is in its original configuration. " What is orginal and non-original config for RAID 1+0? Another point "If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time." I want to move one hdd from each RAID 1 pair. to have mirrors untouched just in case. Do they mean to move all 4 simultaniously? Smart Array 6i User Guide: Moving Drives and Arrays You can move drives to other ID positionson the same array controller. You can also move a complete arrayfrom one controller to another, even if the controllers are on different servers. Before you move drives, the following conditions must be met: • If moving thedrives to a different server, the new server must have enough empty bays to accommodate all the drives simultaneously. • The move will not result in more than 14 physical drives per controller channel. • No controller will be configured with more than 32 logical volumes. • The array has no failed or missing drives. • The array is in its original configuration. • The controller is not reading from or writing to any of the spare drives in the array. • The controller is not running capacity expansion, capacity extension, or RAID or stripe size migration. • The controller is using the latestfirmware version (recommended). If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time. • In most cases, a moved array (and the logical drives that it contains) can still undergo arraycapacity expansion, logical drive capacity extension, or migration of RAID level orstripe size. When all the conditions have been met: Back up all data before removing any drives or changing configuration. This step is requiredif you are moving data-containing drives from a controller that does not have a battery-backed cache. Power down the system. If you are moving an array from a controller that contains a RAID ADG logical volume to a controller that does not support RAID ADG: Move the drives. Power up the system. If a 1724 POST message is displayed, drive positions were changed successfully and the configuration was updated. If a 1785 (NotConfigured)POST message is displayed: a. Power down the system immediately to prevent data loss. b. Return the drives to their original locations. c. Restore the data from backup, if necessary. Check the new drive configuration byrunning ORCA or ACU ("Configuring an Array" on page 9).

    Read the article

  • Bridged virtual interface is not available or visible to ifconfig.

    - by Omniwombat
    Hello all. I'm running Ubuntu 9.04, kernel 2.6.28-18, and vmware-server 2.0.1. I'm attempting to setup a virtual linux machine to use a bridged interface rather than NAT or host-only. Both NAT and host-only work just fine. When running vmware-config.pl, I set /dev/vmnet0 to bridge eth0, /dev/vmnet1 to host-only, and /dev/vmnet8 to NAT. When I run ifconfig -a I see the physical interface (eth0), vmnet1 and vmnet8 both of which are up and have IP addresses assigned to them. I also see other various interfaces that are not relevant here. In the web console, when I ask that the guest machine's network card be bridged, it states that a bridged setup is "Not available" and shows the disabled device icon. Inside the guest machine, I do have an eth0 interface which I can set to anything I like, however it can't see my external network, or the host. I do see errors in my vmware/hostd.log which state: "The network bridge on device vmnet0 is not running. The virtual machine will not be able to communicate with the host or with other machines on your network" which confirms the problem. vmnet-bridge is running, and I see the following in my process table: /usr/bin/vmnet-bridge -d /var/run/vmnet-bridge-0.pid -n 0 -i eth0 I confirm that the /var/run/vmnet-bridge-0.pid file is there and that it points to the correct process. I saw this question relating to Ubuntu 9.04 and bridged interfaces, in which the poster determined that the vsock library was not getting built due to a flaw in the vmware-config.pl script. I applied the patch, reran the script, and confirm that vsock.ko and vsock.o are in my /lib directory structure. vsock does show up in an lsmod. My /etc/vmware directory has /vmnet1 and /vmnet8 subdirectories. They contain configuration utilities for running DHCP and nat type services as expected. There is no vmnet0 subdirectory. My /etc/vmware/netmap.conf file DOES show entries for vmnet0; both the name and the device as I configured it from the script. My /dev directory contains devices vmnet0 through vmnet9. They have major device number 119, and minor device numbers 0 through 9. /proc/net/dev shows statistics for vmnet1 and vmnet8, but not vmnet0. I have a /proc/vmnet directory, but it's empty. When I start or stop the vmware service with /etc/init.d/vmware start, I see the following: Starting VMware services: Virtual machine monitor done Virtual machine communication interface done VM communication interface socket family: done Virtual ethernet done Bridged networking on /dev/vmnet0 done Host-only networking on /dev/vmnet1 (background) done DHCP server on /dev/vmnet1 done Host-only networking on /dev/vmnet8 (background) done DHCP server on /dev/vmnet8 done NAT service on /dev/vmnet8 done VMware Server Authentication Daemon (background) done Shared Memory Available done Starting VMware management services: VMware Server Host Agent (background) done VMware Virtual Infrastructure Web Access Starting VMware autostart virtual machines: Virtual machines done Nothing appears to be wrong there. What n00b thing am I doing such that vmnet0 and only vmnet0 does not show up in the interface list?

    Read the article

  • Hide subdomain AND subdirectory using mod_rewrite?

    - by Jeremy
    I am trying to hide a subdomain and subdirectory from users. I know it may be easier to use a virtual host but will that not change direct links pointing at our site? The site currently resides at http://mail.ctrc.sk.ca/cms/ I want www.ctrc.sk.ca and ctrc.sk.ca to access this folder but still display www.ctrc.sk.ca. If that makes any sense. Here is what our current .htaccess file looks like, we are using Joomla so there already a few rules set up. Help is appreciated. # Helicon ISAPI_Rewrite configuration file # Version 3.1.0.78 ## # @version $Id: htaccess.txt 14401 2010-01-26 14:10:00Z louis $ # @package Joomla # @copyright Copyright (C) 2005 - 2010 Open Source Matters. All rights reserved. # @license http://www.gnu.org/copyleft/gpl.html GNU/GPL # Joomla! is Free Software ## ##################################################### # READ THIS COMPLETELY IF YOU CHOOSE TO USE THIS FILE # # The line just below this section: 'Options +FollowSymLinks' may cause problems # with some server configurations. It is required for use of mod_rewrite, but may already # be set by your server administrator in a way that dissallows changing it in # your .htaccess file. If using it causes your server to error out, comment it out (add # to # beginning of line), reload your site in your browser and test your sef url's. If they work, # it has been set by your server administrator and you do not need it set here. # ##################################################### ## Can be commented out if causes errors, see notes above. #Options +FollowSymLinks # # mod_rewrite in use RewriteEngine On ########## Begin - Rewrite rules to block out some common exploits ## If you experience problems on your site block out the operations listed below ## This attempts to block the most common type of exploit `attempts` to Joomla! # ## Deny access to extension xml files (uncomment out to activate) #<Files ~ "\.xml$"> #Order allow,deny #Deny from all #Satisfy all #</Files> ## End of deny access to extension xml files RewriteCond %{QUERY_STRING} mosConfig_[a-zA-Z_]{1,21}(=|\%3D) [OR] # Block out any script trying to base64_encode crap to send via URL RewriteCond %{QUERY_STRING} base64_encode.*\(.*\) [OR] # Block out any script that includes a <script> tag in URL RewriteCond %{QUERY_STRING} (\<|%3C).*script.*(\>|%3E) [NC,OR] # Block out any script trying to set a PHP GLOBALS variable via URL RewriteCond %{QUERY_STRING} GLOBALS(=|\[|\%[0-9A-Z]{0,2}) [OR] # Block out any script trying to modify a _REQUEST variable via URL RewriteCond %{QUERY_STRING} _REQUEST(=|\[|\%[0-9A-Z]{0,2}) # Send all blocked request to homepage with 403 Forbidden error! RewriteRule ^(.*)$ index.php [F,L] # ########## End - Rewrite rules to block out some common exploits # Uncomment following line if your webserver's URL # is not directly related to physical file paths. # Update Your Joomla! Directory (just / for root) #RewriteBase / ########## Begin - Joomla! core SEF Section # RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteCond %{REQUEST_URI} !^/index.php RewriteCond %{REQUEST_URI} (/|\.php|\.html|\.htm|\.feed|\.pdf|\.raw|/[^.]*)$ [NC] RewriteRule (.*) index.php RewriteRule .* - [E=HTTP_AUTHORIZATION:%{HTTP:Authorization},L] # ########## End - Joomla! core SEF Section EDIT Yes, mail.ctrc.sk.ca/cms/ is the root directory. Currently the DNS redirects from ctrc.sk.ca and www.ctrc.sk.ca to mail.ctrc.sk.ca/cms. However when it redirects the user still sees the mail.ctrc.sk.ca/cms/ url and I want them to only see www.ctrc.sk.ca.

    Read the article

  • Oracle Virtual Server OEL vm fails to start - kernel panic on cpu identify

    - by Towndrunk
    I am in the process of following a guide to setup various oracle vm templates, so far I have installed OVS 2. 2 and got the OVM Manager working, imported the template for OEL5U5 and created a vm from it.. the problem comes when starting that vm. The log in the OVMM console shows the following; Update VM Status - Running Configure CPU Cap Set CPU Cap: failed:<Exception: failed:<Exception: ['xm', 'sched-credit', '-d', '32_EM11g_OVM', '-c', '0'] => Error: Domain '32_EM11g_OVM' does not exist. StackTrace: File "/opt/ovs-agent-2.3/OVSXXenVMConfig.py", line 2531, in xen_set_cpu_cap run_cmd(args=['xm', File "/opt/ovs-agent-2.3/OVSCommons.py", line 92, in run_cmd raise Exception('%s => %s' % (args, err)) The xend.log shows; [2012-11-12 16:42:01 7581] DEBUG (DevController:139) Waiting for devices vtpm [2012-11-12 16:42:01 7581] INFO (XendDomain:1180) Domain 32_EM11g_OVM (3) unpaused. [2012-11-12 16:42:03 7581] WARNING (XendDomainInfo:1907) Domain has crashed: name=32_EM11g_OVM id=3. [2012-11-12 16:42:03 7581] ERROR (XendDomainInfo:2041) VM 32_EM11g_OVM restarting too fast (Elapsed time: 11.377262 seconds). Refusing to restart to avoid loops .> [2012-11-12 16:42:03 7581] DEBUG (XendDomainInfo:2757) XendDomainInfo.destroy: domid=3 [2012-11-12 16:42:12 7581] DEBUG (XendDomainInfo:2230) Destroying device model [2012-11-12 16:42:12 7581] INFO (image:553) 32_EM11g_OVM device model terminated I have set_on_crash="preserve" in the vm.cfg and have then run xm create -c to get the console screen while booting and this is the log of what happens.. Started domain 32_EM11g_OVM (id=4) Bootdata ok (command line is ro root=LABEL=/ ) Linux version 2.6.18-194.0.0.0.3.el5xen ([email protected]) (gcc version 4.1.2 20080704 (Red Hat 4.1.2-48)) #1 SMP Mon Mar 29 18:27:00 EDT 2010 BIOS-provided physical RAM map: Xen: 0000000000000000 - 0000000180800000 (usable)> No mptable found. Built 1 zonelists. Total pages: 1574912 Kernel command line: ro root=LABEL=/ Initializing CPU#0 PID hash table entries: 4096 (order: 12, 32768 bytes) Xen reported: 1600.008 MHz processor. Console: colour dummy device 80x25 Dentry cache hash table entries: 1048576 (order: 11, 8388608 bytes) Inode-cache hash table entries: 524288 (order: 10, 4194304 bytes) Software IO TLB disabled Memory: 6155256k/6299648k available (2514k kernel code, 135548k reserved, 1394k data, 184k init) Calibrating delay using timer specific routine.. 4006.42 BogoMIPS (lpj=8012858) Security Framework v1.0.0 initialized SELinux: Initializing. selinux_register_security: Registering secondary module capability Capability LSM initialized as secondary Mount-cache hash table entries: 256 CPU: L1 I Cache: 64K (64 bytes/line), D cache 16K (64 bytes/line) CPU: L2 Cache: 2048K (64 bytes/line) general protection fault: 0000 [1] SMP last sysfs file: CPU 0 Modules linked in: Pid: 0, comm: swapper Not tainted 2.6.18-194.0.0.0.3.el5xen #1 RIP: e030:[ffffffff80271280] [ffffffff80271280] identify_cpu+0x210/0x494 RSP: e02b:ffffffff80643f70 EFLAGS: 00010212 RAX: 0040401000810008 RBX: 0000000000000000 RCX: 00000000c001001f RDX: 0000000000404010 RSI: 0000000000000001 RDI: 0000000000000005 RBP: ffffffff8063e980 R08: 0000000000000025 R09: ffff8800019d1000 R10: 0000000000000026 R11: ffff88000102c400 R12: 0000000000000000 R13: 0000000000000000 R14: 0000000000000000 R15: 0000000000000000 FS: 0000000000000000(0000) GS:ffffffff805d2000(0000) knlGS:0000000000000000 CS: e033 DS: 0000 ES: 0000 Process swapper (pid: 0, threadinfo ffffffff80642000, task ffffffff804f4b80) Stack: 0000000000000000 ffffffff802d09bb ffffffff804f4b80 0000000000000000 0000000021100800 0000000000000000 0000000000000000 ffffffff8064cb00 0000000000000000 0000000000000000 Call Trace: [ffffffff802d09bb] kmem_cache_zalloc+0x62/0x80 [ffffffff8064cb00] start_kernel+0x210/0x224 [ffffffff8064c1e5] _sinittext+0x1e5/0x1eb Code: 0f 30 b8 73 00 00 00 f0 0f ab 45 08 e9 f0 00 00 00 48 89 ef RIP [ffffffff80271280] identify_cpu+0x210/0x494 RSP ffffffff80643f70 0 Kernel panic - not syncing: Fatal exception clear as mud to me. are there any other logs that will help me? I have now deployed another vm from the same template and used the default vm settings rather than adding more memory etc - I get exactly the same error.

    Read the article

  • SmartOS reboots spontaneously

    - by Alex
    I run a SmartOS system on a Hetzner EX4S (Intel Core i7-2600, 32G RAM, 2x3Tb SATA HDD). There are six virtual machines on the host: [root@10-bf-48-7f-e7-03 ~]# vmadm list UUID TYPE RAM STATE ALIAS d2223467-bbe5-4b81-a9d1-439e9a66d43f KVM 512 running xxxx1 5f36358f-68fa-4351-b66f-830484b9a6ee KVM 1024 running xxxx2 d570e9ac-9eac-4e4f-8fda-2b1d721c8358 OS 1024 running xxxx3 ef88979e-fb7f-460c-bf56-905755e0a399 KVM 1024 running xxxx4 d8e06def-c9c9-4d17-b975-47dd4836f962 KVM 4096 running xxxx5 4b06fe88-db6e-4cf3-aadd-e1006ada7188 KVM 9216 running xxxx5 [root@10-bf-48-7f-e7-03 ~]# The host reboots several times a week with no crash dump in /var/crash and no messages in the /var/adm/messages log. Basically /var/adm/messages looks like there was a hard reset: 2012-11-23T08:54:43.210625+00:00 10-bf-48-7f-e7-03 rsyslogd: -- MARK -- 2012-11-23T09:14:43.187589+00:00 10-bf-48-7f-e7-03 rsyslogd: -- MARK -- 2012-11-23T09:34:43.165100+00:00 10-bf-48-7f-e7-03 rsyslogd: -- MARK -- 2012-11-23T09:54:43.142065+00:00 10-bf-48-7f-e7-03 rsyslogd: -- MARK -- 2012-11-23T10:14:43.119365+00:00 10-bf-48-7f-e7-03 rsyslogd: -- MARK -- 2012-11-23T10:34:43.096351+00:00 10-bf-48-7f-e7-03 rsyslogd: -- MARK -- 2012-11-23T10:54:43.073821+00:00 10-bf-48-7f-e7-03 rsyslogd: -- MARK -- 2012-11-23T10:57:55.610954+00:00 10-bf-48-7f-e7-03 genunix: [ID 540533 kern.notice] #015SunOS Release 5.11 Version joyent_20121018T224723Z 64-bit 2012-11-23T10:57:55.610962+00:00 10-bf-48-7f-e7-03 genunix: [ID 299592 kern.notice] Copyright (c) 2010-2012, Joyent Inc. All rights reserved. 2012-11-23T10:57:55.610967+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: lgpg 2012-11-23T10:57:55.610971+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: tsc 2012-11-23T10:57:55.610974+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: msr 2012-11-23T10:57:55.610978+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: mtrr 2012-11-23T10:57:55.610981+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: pge 2012-11-23T10:57:55.610984+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: de 2012-11-23T10:57:55.610987+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: cmov 2012-11-23T10:57:55.610995+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: mmx 2012-11-23T10:57:55.611000+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: mca 2012-11-23T10:57:55.611004+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: pae 2012-11-23T10:57:55.611008+00:00 10-bf-48-7f-e7-03 unix: [ID 223955 kern.info] x86_feature: cv8 The problem is that sometimes the host loses the network interface on reboot so we need to perform a manual hardware reset to bring it back. We do not have physical or virtual access to the server console - no KVM, no iLO or anything like this. So, the only way to debug is to analyze crash dumps/log files. I am not a SmartOS/Solaris expert so I am not sure how to proceed. Is there any equivalent of Linux netconsole for SmartOS? Can I just redirect the console output to the network port somehow? Maybe I am missing something obvious and crash information is located somewhere else.

    Read the article

  • How to Eliminate Tape Backup and Off-site Storage Service?

    - by Daniel Lucas
    PLEASE READ UPDATE AT THE BOTTOM. THANKS! ;) Environment Info (all Windows): 2 sites 30 servers site #1 (3TB of backup data) 5 servers site #2 (1TB of backup data) MPLS backbone tunnel connecting site #1 and site #2 Current Backup Process: Online Backup (disk-to-disk) Site #1 has a server running Symantec Backup Exec 12.5 with four 1TB USB 2.0 disks. BE jobs for full backups run nightly on all servers in site #1 to these disks. Site #2 backs up to a central file server there using software they already had when we purchased them. A BE job pulls that data nightly to site #1 and stores them on said disks. Off-site Backup (tape) Connected to our backup server is a tape drive. BE backs up the external disks to tape once a week which gets picked up by our off-site storage company. Obviously we rotate two tape libraries, one is always here and one is always there. Requirements: Eliminate the need for tape and off-site storage service by doing disk-to-disk at each site and replicating site #1 to site #2 and vice versa. Software based solution as hardware options have been too pricey (ie, SonicWall, Arkeia). Agents for Exchange, SharePoint, and SQL. Some Ideas So Far: Storage DroboPro at each site with an initial 8TB of storage (these are expandable up to 16TB at present). I like these because they are rackmountable, allow disparate drives, and have iSCSI interfaces. They are relatively cheap too. Software Symantec Backup Exec 12.5 already has all the agents and licenses we need. I'd like to keep using it unless there is a better solution, similarly priced, that does everything BE does plus deduplication and replication. Server Because there is no more need for a SCSI adapter (for tape drive) we are going to virtualize our backup server as it is currently the only physical machine save for SQL boxes. Problems: When replicating between sites we want as little data as possible to go across the pipe. There is no deduplication or compression in what I have laid out here so far. The files being replicated are BE's virtual tape libraries from our disk-to-disk backup. Because of this each of those huge files will go across the wire every week because they change every day. And Finally, the Question: Is there any software out there that does deduplication, or at least compression, to handle just our site-to-site replication? Or, looking at our setup, is there any other solution that I am missing that might be cheaper, faster, better? Thanks. Sorry so long. UPDATE 2: I've set a bounty on this question to get it more attention. I'm looking for software that will handle replication of data between two sites using the least amount of data possible (either compression, deduplication, or some other method). Something similar to rsync would work but it needs to be native to Windows and not a port involving shenanigans to get up and running. Prefer a GUI based product and I don't mind shelling out a few bones if it works. Please, answers that meet the above criteria only. If you don't think one exists or if you think I'm being to restrictive keep it to yourself. If after seven days there is no answer at all, so be it. Thanks again everyone. UPDATE 2: I really appreciate everyone coming forward with suggestions. There is no way for me to try all of these before the bounty expires. For now I'm going to let this bounty run out and whoever has the most votes will get the 100 rep points. Thanks again!

    Read the article

  • Dynamic DNS registration for VPN clients

    - by Eric Falsken
    I've got a VPN server set up in my Active Directory on a remote network. (VPN Server is separate box from DNS/AD) When I dial into the network (client machine is not a member of the AD) the machine does not register its IP or Hostname in the DNS. I've played with all possible combinations of DHCP and RRAS-allocated IP pools, and none of them seem to cause my client to register. Is it because my client has to be a member of the domain? Are there some security settins I can tweak so that it can register its hostname/ip? I've looked in the event logs (System and Security) for the AD, DNS, DHCP, RRAS, and the client machine, and don't see anything relating to DNS Registration. Here's the IPConfig on the client machine (once connected): PPP adapter My VPN Name: Connection-specific DNS Suffix . : mydomain.local Description . . . . . . . . . . . : My VPN Name Physical Address. . . . . . . . . : DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes IPv4 Address. . . . . . . . . . . : 192.168.1.22(Preferred) Subnet Mask . . . . . . . . . . . : 255.255.255.255 Default Gateway . . . . . . . . . : DNS Servers . . . . . . . . . . . : 192.168.1.52 <- DC1 192.168.1.53 <- DC2 NetBIOS over Tcpip. . . . . . . . : Enabled

    Read the article

  • Causes of sudden massive filesystem damage? ("root inode is not a directory")

    - by poolie
    I have a laptop running Maverick (very happily until yesterday), with a Patriot Torx SSD; LUKS encryption of the whole partition; one lvm physical volume on top of that; then home and root in ext4 logical volumes on top of that. When I tried to boot it yesterday, it complained that it couldn't mount the root filesystem. Running fsck, basically every inode seems to be wrong. Both home and root filesystems show similar problems. Checking a backup superblock doesn't help. e2fsck 1.41.12 (17-May-2010) lithe_root was not cleanly unmounted, check forced. Resize inode not valid. Recreate? no Pass 1: Checking inodes, blocks, and sizes Root inode is not a directory. Clear? no Root inode has dtime set (probably due to old mke2fs). Fix? no Inode 2 is in use, but has dtime set. Fix? no Inode 2 has a extra size (4730) which is invalid Fix? no Inode 2 has compression flag set on filesystem without compression support. Clear? no Inode 2 has INDEX_FL flag set but is not a directory. Clear HTree index? no HTREE directory inode 2 has an invalid root node. Clear HTree index? no Inode 2, i_size is 9581392125871137995, should be 0. Fix? no Inode 2, i_blocks is 40456527802719, should be 0. Fix? no Reserved inode 3 (<The ACL index inode>) has invalid mode. Clear? no Inode 3 has compression flag set on filesystem without compression support. Clear? no Inode 3 has INDEX_FL flag set but is not a directory. Clear HTree index? no .... Running strings across the filesystems, I can see there are what look like filenames and user data there. I do have sufficiently good backups (touch wood) that it's not worth grovelling around to pull back individual files, though I might save an image of the unencrypted disk before I rebuild, just in case. smartctl doesn't show any errors, neither does the kernel log. Running a write-mode badblocks across the swap lv doesn't find problems either. So the disk may be failing, but not in an obvious way. At this point I'm basically, as they say, fscked? Back to reinstalling, perhaps running badblocks over the disk, then restoring from backup? There doesn't even seem to be enough data to file a meaningful bug... I don't recall that this machine crashed last time I used it. At this point I suspect a bug or memory corruption caused it to write garbage across the disks when it was last running, or some kind of subtle failure mode for the SSD. What do you think would have caused this? Is there anything else you'd try?

    Read the article

  • Putting indexes in separate filegroup kills our queries

    - by womp
    Can anyone shed some light on this? On our dev boxes, our database resides entirely in the PRIMARY filegroup, and everything works fine. On one of our production servers, recently upgraded from 2005 to 2008, we noticed it was performing slower than it should. On this machine, there are two filegroups - PRIMARY and INDEXES. Both filegroups contain 1 file per logical volume, one logical volume per CPU, (and each logical volume is a RAID 10 of 4 physical disks). We isolated a few queries that were performing fast on the dev boxes and slow (up to 40x slower) on the production machine. Turned out these queries were using the non-clustered indexes that resided in the INDEXES filegroup. Tweaking some of the queries to only use clustered indexes that were in the PRIMARY filegroup dropped their times back to normal. As a final confirmation, we redeployed the same database on the same machine to have everything in PRIMARY, and things went back to normal! Here's the statistics output of one of the queries, run identically on the machine with different filegroup configurations (table names changed to protect the innocent): FAST (everything in PRIMARY filegroup): (3 row(s) affected) Table '0'. Scan count 2, logical reads 14, ... Table '1'. Scan count 0, logical reads 0, ... Table '1'. Scan count 0, logical reads 0, ... Table '2'. Scan count 2, logical reads 7, ... Table '3'. Scan count 2, logical reads 1012, ... Table '4'. Scan count 1, logical reads 3, ... SQL Server Execution Times: CPU time = 437 ms, elapsed time = 445 ms. SLOW (indexes split into their own filegroup): (3 row(s) affected) Table '0'. Scan count 209, logical reads 428, ... Table '1'. Scan count 0, logical reads 0,... Table '2'. Scan count 1021, logical reads 9043,.... Table '3'. Scan count 209, logical reads 105754, .... Table '4'. Scan count 0, logical reads 0, .... Table '5'. Scan count 1, logical reads 695, ... **Table '#46DA8CA9'. Scan count 205, logical reads 205, ...** Table '6'. Scan count 6, logical reads 436, ... Table '7'. Scan count 1, logical reads 12,.... SQL Server Execution Times: CPU time = 17581 ms, elapsed time = 17595 ms. Notice the weird temp table and extra tables involved in the slow query. It seems clear that having a second file group is making SQL Server batty with choosing an execution plan. What the heck is going on?

    Read the article

  • Proliant server will not accept new hard disks in RAID 1+0?

    - by Leigh
    I have a HP ProLiant DL380 G5, I have two logical drives configured with RAID. I have one logical drive RAID 1+0 with two 72 gb 10k sas 1 port spare no 376597-001. I had one hard disk fail and ordered a replacement. The configuration utility showed error and would not rebuild the RAID. I presumed a hard disk fault and ordered a replacement again. In the mean time I put the original failed disk back in the server and this started rebuilding. Currently shows ok status however in the log I can see hardware errors. The new disk has come and I again have the same problem of not accepting the hard disk. I have updated the P400 controller with the latest firmware 7.24 , but still no luck. The only difference I can see is the original drive has firmware 0103 (same as the RAID drive) and the new one has HPD2. Any advice would be appreciated. Thanks in advance Logs from server ctrl all show config Smart Array P400 in Slot 1 (sn: PAFGK0P9VWO0UQ) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 1, Interim Recovery Mode) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 73.5 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, Failed array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK) ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAFGK0P9VWO0UQ Cache Serial Number: PA82C0J9VWL8I7 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: E Firmware Version: 7.24 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Status Details: A cache error was detected. Run more information. Cache Ratio: 100% Read / 0% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: Failed Physical Drive Array Type: Data One of the drives on this array have failed or has Logical Drive: 1 Size: 68.5 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17594 Strip Size: 128 KB Full Stripe Size: 128 KB Status: Interim Recovery Mode Caching: Enabled Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive0 Mount Points: C:\ 68.5 GB Logical Drive Label: A0100539PAFGK0P9VWO0UQ0E93 Mirror Group 0: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, S Mirror Group 1: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, S Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 73.5 GB Rotational Speed: 10000 Firmware Revision: 0103 Serial Number: B379P8C006RK Model: HP DG072A9B7 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: Failed Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: D5A1PCA04SL01244 Model: HP EH0072FARUA PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data Logical Drive: 2 Size: 558.7 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Co Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive1 Mount Points: E:\ 558.7 GB Logical Drive Label: AF14FD12PAFGK0P9VWO0UQD007 Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE07QH300009923X1X3 Model: HP DG0300BALVP Current Temperature (C): 32 Maximum Temperature (C): 45 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE0AHVH00009924P8F3 Model: HP DG0300BALVP Current Temperature (C): 34 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE08NAK00009924KWD6 Model: HP DG0300BALVP Current Temperature (C): 35 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown

    Read the article

  • Cisco 678 Will Not Work using PPPoE - Possibly Because I Configured it Incorrectly..?

    - by Brian Stinar
    I am attempting to configure a Cisco 678 because I am totally sick on my Actiontec. However, I am running into some problems. It seems as though the Cisco is able to train the line, but I am unable to ping out. I am all right at programming, but still learning a lot when it comes to being a system administrator. I apologize in advance if I did something ridiculous, or am attempting to configure this device to do something it was not designed to do. It is almost like I am not correctly configuring the device to grab it's IP using PPPoA (like my Actiontec.) The output from "show running" (below) makes me think this too. Below are the commands I ran in order to configure this: # en # set nvram erase # write # reboot # en # set nat enable # set dhcp server enable # set PPP wan0-0 ipcp 0.0.0.0 # set ppp wan0-0 dns 0.0.0.0 # set PPP wan0-0 login xxxxx // My actual login # set PPP wan0-0 password yyyyy // My actual password # set PPP restart enabled # set int wan0-0 close # set int wan0-0 vpi 0 # set int wan0-0 vci 32 # set int wan0-0 open # write # reboot Here is the output from a few commands I thought could provide some useful information: cbos#ping 74.125.224.113 Sending 1 8 byte ping(s) to 74.125.224.113 every 2 second(s) Request timed out cbos#show version Cisco Broadband Operating System CBOS (tm) 678 Software (C678-I-M), Version v2.4.9 - Release Software Copyright (c) 1986-2001 by cisco Systems, Inc. Compiled Nov 17 2004 15:26:29 DMT FULL firmware version G96 NVRAM image at 0x1030f000 cbos#show errors - Current Error Messages - ## Ticks Module Level Message 0 000:00:00:00 PPP Info IPCP Open Event on wan0-0 1 000:00:00:14 ATM Info Wan0 Up 2 000:00:00:14 PPP Info PPP Up Event on wan0-0 3 000:00:01:54 PPP Info PPP Down Event on wan0-0 Total Number of Error Messages: 4 cbos#show interface wan0 wan0 ADSL Physical Port Line Trained Actual Configuration: Overhead Framing: 3 Trellis Coding: Enabled Standard Compliance: T1.413 Downstream Data Rate: 1184 Kbps Upstream Data Rate: 928 Kbps Interleave S Downstream: 4 Interleave D Downstream: 16 Interleave R Downstream: 16 Interleave S Upstream: 4 Interleave D Upstream: 8 Interleave R Upstream: 16 Modem Microcode: G96 DSP version: 0 Operating State: Showtime/Data Mode Configured: Echo Cancellation: Disabled Overhead Framing: 3 Coding Gain: Auto TX Power Attenuation: 0dB Trellis Coding: Enabled Bit Swapping: Disabled Standard Compliance: T1.413 Remote Standard Compliance: T1.413 Tx Start Bin: 0x6 Tx End Bin: 0x1f Data Interface: Utopia L1 Status: Local SNR Margin: 19.0dB Local Coding Gain: 7.5dB Local Transmit Power: 12.5dB Local Attenuation: 46.0dB Remote Attenuation: 31.0dB Local Counters: Interleaved RS Corrected Bytes: 0 Interleaved Symbols with CRC Errors: 2 No Cell Delineation Interleaved: 0 Out of Cell Delineation Interleaved: 0 Header Error Check Counter Interleaved: 0 Count of Severely Errored Frames: 0 Count of Loss of Signal Frames: 0 Remote Counters: Interleaved RS Corrected Bytes: 0 Interleaved Symbols with CRC Errors: 1 No Cell Delineation Interleaved: 0 Header Error Check Counter Interleaved: 0 Count of Severely Errored Frames: 0 Count of Loss of Signal Frames: 0 cbos#show int wan0-0 WAN0-0 ATM Logical Port PVC (VPI 0, VCI 32) is configured. ScalaRate set to Auto AAL 5 UBR Traffic IP Port Enabled cbos#show running Warning: traffic may pause while NVRAM is being accessed [[ CBOS = Section Start ]] NSOS MD5 Enable Password = XXXX NSOS MD5 Root Password = XXXX NSOS MD5 Commander Password = XXXX [[ PPP Device Driver = Section Start ]] PPP Port User Name = 00, "XXXX" PPP Port User Password = 00, XXXX PPP Port Option = 00, IPCP,IP Address,3,Auto,Negotiation Not Required,Negotiable ,IP,0.0.0.0 PPP Port Option = 00, IPCP,Primary DNS Server,129,Auto,Negotiation Not Required, Negotiable,IP,0.0.0.0 PPP Port Option = 00, IPCP,Secondary DNS Server,131,Auto,Negotiation Not Require d,Negotiable,IP,0.0.0.0 [[ ATM WAN Device Driver = Section Start ]] ATM WAN Virtual Connection Parms = 00, 0, 32, 0 [[ DHCP = Section Start ]] DHCP Server = enabled [[ IP Routing = Section Start ]] IP NAT = enabled [[ WEB = Section Start ]] WEB = enabled cbos# wtf...? Thank you all very much for taking the time to read this, and the help.

    Read the article

  • Why are USB 2.0 devices crashing my system?

    - by BenAlabaster
    Background on the machine I'm having a problem with: The machine was inherited and appears to be circa 2003 (there's a date stamp on the power supply which leads me to this conclusion). I've got it set up as a Skype terminal for my 2 year old to keep in touch with her grandparents and other members of the family - which everyone loves. It has a generic baby-ATX motherboard with no identifying markings. CPU-Z identifies the motherboard model as VT8601 but doesn't provide me with any manufacturer name. There's one stamp on the motherboard that says "Rev.B". On board it has 10/100 LAN, 2 x USB 1.0, VGA, PS/2 for KB and mouse, parallel port, 2 x serial ports, 2 x IDE, 1 x floppy, 2 x SDRAM slots, 1 x CPU housing that is seating a 1.3GHz Intel Celeron CPU, 3 x PCI, 1 x AGP - although you can only use 2 of the PCI slots if you use the AGP slot due to the physical layout of the board. It's got 768Mb PC133 SDRAM - 1 x 512Mb & 1 x 256Mb installed as well as a D-LINK WDA-2320 54G Wi-Fi network card and a generic USB 2.0 expansion board containing 3 x external + 1 x internal USB connectors. All this is sitting in a slimline case. I don't know the wattage of the PSU, but can post this later if this proves to be helpful. The motherboard is running a version of Award BIOS for which I don't have the version number to hand but can again post this later if it would be helpful. It has an 80Gb Western Digital hard drive freshly formatted and built with Windows XP Professional with Service Pack 3 and all current patches. In addition to Windows XP, the only other software it's running is Skype 4.1 (4.2 crashes the machine as soon as it starts up). It's got a Daytek MV150 15" touch screen running through the VGA and COM1 with the most current drivers from the Daytek website and the most current version of ELO-Touchsystems drivers for the touch component. The webcam is a Logitech Webcam C200 with the latest drivers from the Logitech website. The problem If I hook any USB 2.0 devices to this machine, it hangs the whole machine and I have to hard boot it to get it back up. Workarounds found I can plug the same devices into the on board USB 1.0 connectors and everything works fine, albeit at reduced performance. I've tried 3 different kinds of USB thumb drives, 3 different makes/models of webcams and my iPhone all with the same effect. They're recognized and don't hang the machine when I hook them to the USB 1.0 but if I hook them to the USB 2.0 ports, the machine hangs within a couple of seconds of recognizing the devices were connected. Attempted solutions I've tried disabling all the on board devices that I'm not using - such as the on board LAN, the second COM port, the AGP connector etc. through the BIOS in an (perhaps misguided or futile) attempt to reduce the power consumption... I don't think it had any effect but it didn't do any harm. I was wondering if the PSU wattage just isn't enough to drive the USB 2.0 devices; I've seen this suggested but haven't found any confirmation that this could really be an issue - nor have I found a way to work around this issue - if indeed it is one. Any ideas? The only thing I haven't done which I only just thought of while writing this essay is trying the USB 2.0 card in a different PCI slot, or re-ordering the wi-fi and USB cards in the slots... although I'm not sure if this will make any difference. I've installed the USB card in another machine and it works without issue, so it's not a problem with the USB card itself. Other thoughts Perhaps this is an incompatibility between the USB 2.0 card and the BIOS, would re-flashing the BIOS with a newer version help? Do I need to be able to identify the manufacturer of the motherboard in order to be able to find a BIOS edition specific for this motherboard or will any version of Award BIOS function in its place? Question Does anyone have any ideas that could help me get my USB 2.0 devices hooked up to this machine?

    Read the article

  • Where is my VMware-ws FreeNAS CIFS(ZFS) bottle-neck?

    - by maka
    Background: I'm building a quiet HTPC + NAS that is also supposed to be used for general computer usage. I'm so far generally happy with things, it was just that I was expecting a little better IO performance. I have no clue if my expectations are unreal. The NAS is there as a general purpose file storage and as a media server for XBMC and other devices. ZFS is a requirement. Question: Where is my bottle-neck, and is there anything I can do config wise, to improve my performance? I'm thinking VM-disk settings could be something but I really have no idea where to go since I'm neither experienced with FreeNAS nor VMware-WS. Tests: When I'm on the host OS and copy files (from the SSD) to the CIFS share, I get around 30 Mbytes/sec read and write. When I'm on my laptop laptop, wired to the network, I get about the same specs. The test I've done are with a 16 GB ISO, and with about 200 MB of RARs and I've tried avoiding the RAM-cache by reading different files than the ones I'm writing ( 10 GB). It feels like having less CPU cores is a lot more efficient, since the resource manager in Windows reports less CPU-usage. With 4 cores in VMware, CPU usage was 50-80%, with 1 core it was 25-60%. EDIT: HD ActiveTime was quite high on SSD so I moved the page file, disabled hibernate and enabled Win DiskCache both on SSD and RAID. This resulted in no real performance difference for one file, but if i transferred 2 files the total speed went up to 50 Mbytes/s vs ~40. The ActiveTime avg also went down a lot (to ~20%) but has now higher bursts. DiskIO is on ~ 30-35 Mbytes/s avgs, with ~100Mb bursts. Network is on 200-250Mbits/s with ~45 active TCP connections. Hardware Asus F2A85-M Pro A10-5700 16GB DDR3 1600 OCZ Vertex 2 128GB SSD 2x Generic 1tb 7200 RPM drives as RAID0 (in win7) Intel Gigabit Desktop CT Software Host OS: Win7 (SSD) VMware Worksation 9 (SSD) FreeNAS 8.3 VM (20GB VDisk on SSD) CPU: I've tried 1, 2 and 4 cores. Virtualisation engine, Preferred mode: Automatic 10,24Gb ram 50Gb SCSI VDisk on the RAID0, VDisk is formatted as ZFS and exposed through CIFS through FreeNAS. NIC Bridge, Replicate physical network state Below are two typical process print-outs while I'm transfering one file to the CIFS share. last pid: 2707; load averages: 0.60, 0.43, 0.24 up 0+00:07:05 00:34:26 32 processes: 2 running, 30 sleeping Mem: 101M Active, 53M Inact, 1620M Wired, 2188K Cache, 149M Buf, 8117M Free Swap: 4096M Total, 4096M Free PID USERNAME THR PRI NICE SIZE RES STATE TIME WCPU COMMAND 2640 root 1 102 0 50164K 10364K RUN 0:25 25.98% smbd 1897 root 6 44 0 168M 74808K uwait 0:02 0.00% python last pid: 2746; load averages: 0.93, 0.60, 0.33 up 0+00:08:53 00:36:14 33 processes: 2 running, 31 sleeping Mem: 101M Active, 53M Inact, 4722M Wired, 2188K Cache, 152M Buf, 5015M Free Swap: 4096M Total, 4096M Free PID USERNAME THR PRI NICE SIZE RES STATE TIME WCPU COMMAND 2640 root 1 76 0 50164K 10364K RUN 0:52 16.99% smbd 1897 root 6 44 0 168M 74816K uwait 0:02 0.00% python I'm sorry if my question isn't phrased right, I'm really bad at these kind of things, and it is the first time I post here at SU. I also appreciate any other suggestions to something, I could have missed.

    Read the article

  • Do hard drive enclosures fail/is it the HDD or enclosure?

    - by x0a
    I'm having a whole host of problems with an external hard drive that was working just fine a couple of hours ago. I've had this problem before once, and that was about 3 months ago, here's what I documented: So a couple of hours ago I turned off all my computers and shut off the power to all my devices in my room, then went and turned the power off at the main switch so I could change an outlet. A couple hours later, after I've already slowly turned everything back on, I go to my xbox to try and watch a movie and it can't seem to list any of the movies I've got. So I go to my desktop to find that my external hard drive isn't there.. even though it's on and connected. It's also stationary and hidden behind something so there's not a whole lot of tampering/physical wear to that external. I plug it into my laptop to try and see what's going on. It starts making this endless loud screeching noise. None of that clicking that's usually associated with hd damage. It's not listed in my computers, and it shows up in Disk Management as "uninitialized" asking me to choose between two different partition types. After carefully disconnecting it and connecting it back, it asks me to format it, which I cancel. I start googling about my issue, starting to accept the situation, torn as hell and helpless and just about ready to toss the thing. Suddenly the screeching stops, after almost 45 minutes of it going, and Disk Management lists the drive as "Online" and "Healthy". Explorer pops up with all my files! I'm still being really careful with it and weary and treating it as though it's in fragile shape. I've downloaded some S.M.A.R.T. software to read the values and everything is listed as "OK" . No reallocated sectors, no read errors, no seek errors. I also ran a quick self-test, which completed without error. Everything seems fine. It looks to be a perfectly healthy external hard drive. So what the hell was that about? Was it doing some sort of maintenance or self-test? How am I supposed to tell the difference? I would've undoubtedly killed the drive for sure if had it gone on a bit longer. I've got the same problem now, with one exception: it doesn't magically reappear after the screeching stops. Occasionally I manage to get some S.M.A.R.T. diagnostics information, which basically reads everything as fine. The only problem is that my HD isn't initializing (so I can't access anything in it). I'm able to successfully run a quick smart test but not an extended one (I've only tried it once but got conflicting indications as to whether it was actually making any progress or not (was stuck on Random read test). So, final question (if all else fails): Could the hard drive enclosure be failing rather than the HDD? Is this a likely possibility at all? How would I know?

    Read the article

  • volume group disappeared after xfs_check run

    - by John P
    EDIT** I have a volume group consisting of 5 RAID1 devices grouped together into a lvm and formatted with xfs. The 5th RAID device lost its RAID config (cat /proc/mdstat does not show anything). The two drives are still present (sdj and sdk), but they have no partitions. The LVM appeared to be happily using sdj up until recently. (doing a pvscan showed the first 4 RAID1 devices + /dev/sdj) I removed the LVM from the fstab, rebooted, then ran xfs_check on the LV. It ran for about half an hour, then stopped with an error. I tried rebooting again, and this time when it came up, the logical volume was no longer there. It is now looking for /dev/md5, which is gone (though it had been using /dev/sdj earlier). /dev/sdj was having read errors, but after replacing the SATA cable, those went away, so the drive appears to be fine for now. Can I modify the /etc/lvm/backup/dedvol, change the device to /dev/sdj and do a vgcfgrestore? I could try doing a pvcreate --uuid KZron2-pPTr-ZYeQ-PKXX-4Woq-6aNc-AG4rRJ /dev/sdj to make it recognize it, but I'm afraid that would erase the data on the drive UPDATE: just changing the pv to point to /dev/sdj did not work vgcfgrestore --file /etc/lvm/backup/dedvol dedvol Couldn't find device with uuid 'KZron2-pPTr-ZYeQ-PKXX-4Woq-6aNc-AG4rRJ'. Cannot restore Volume Group dedvol with 1 PVs marked as missing. Restore failed. pvscan /dev/sdj: read failed after 0 of 4096 at 0: Input/output error Couldn't find device with uuid 'KZron2-pPTr-ZYeQ-PKXX-4Woq-6aNc-AG4rRJ'. Couldn't find device with uuid 'KZron2-pPTr-ZYeQ-PKXX-4Woq-6aNc-AG4rRJ'. Couldn't find device with uuid 'KZron2-pPTr-ZYeQ-PKXX-4Woq-6aNc-AG4rRJ'. Couldn't find device with uuid 'KZron2-pPTr-ZYeQ-PKXX-4Woq-6aNc-AG4rRJ'. PV /dev/sdd2 VG VolGroup00 lvm2 [74.41 GB / 0 free] PV /dev/md2 VG dedvol lvm2 [931.51 GB / 0 free] PV /dev/md3 VG dedvol lvm2 [931.51 GB / 0 free] PV /dev/md0 VG dedvol lvm2 [931.51 GB / 0 free] PV /dev/md4 VG dedvol lvm2 [931.51 GB / 0 free] PV unknown device VG dedvol lvm2 [1.82 TB / 63.05 GB free] Total: 6 [5.53 TB] / in use: 6 [5.53 TB] / in no VG: 0 [0 ] vgscan Reading all physical volumes. This may take a while... /dev/sdj: read failed after 0 of 4096 at 0: Input/output error /dev/sdj: read failed after 0 of 4096 at 2000398843904: Input/output error Found volume group "VolGroup00" using metadata type lvm2 Found volume group "dedvol" using metadata type lvm2 vgdisplay dedvol --- Volume group --- VG Name dedvol System ID Format lvm2 Metadata Areas 5 Metadata Sequence No 10 VG Access read/write VG Status resizable MAX LV 0 Cur LV 1 Open LV 0 Max PV 0 Cur PV 5 Act PV 5 VG Size 5.46 TB PE Size 4.00 MB Total PE 1430796 Alloc PE / Size 1414656 / 5.40 TB Free PE / Size 16140 / 63.05 GB VG UUID o1U6Ll-5WH8-Pv7Z-Rtc4-1qYp-oiWA-cPD246 dedvol { id = "o1U6Ll-5WH8-Pv7Z-Rtc4-1qYp-oiWA-cPD246" seqno = 10 status = ["RESIZEABLE", "READ", "WRITE"] flags = [] extent_size = 8192 # 4 Megabytes max_lv = 0 max_pv = 0 physical_volumes { pv0 { id = "Msiee7-Zovu-VSJ3-Y2hR-uBVd-6PaT-Ho9v95" device = "/dev/md2" # Hint only status = ["ALLOCATABLE"] flags = [] dev_size = 1953519872 # 931.511 Gigabytes pe_start = 384 pe_count = 238466 # 931.508 Gigabytes } pv1 { id = "ZittCN-0x6L-cOsW-v1v4-atVN-fEWF-e3lqUe" device = "/dev/md3" # Hint only status = ["ALLOCATABLE"] flags = [] dev_size = 1953519872 # 931.511 Gigabytes pe_start = 384 pe_count = 238466 # 931.508 Gigabytes } pv2 { id = "NRNo0w-kgGr-dUxA-mWnl-bU5v-Wld0-XeKVLD" device = "/dev/md0" # Hint only status = ["ALLOCATABLE"] flags = [] dev_size = 1953519872 # 931.511 Gigabytes pe_start = 384 pe_count = 238466 # 931.508 Gigabytes } pv3 { id = "2EfLFr-JcRe-MusW-mfAs-WCct-u4iV-W0pmG3" device = "/dev/md4" # Hint only status = ["ALLOCATABLE"] flags = [] dev_size = 1953519872 # 931.511 Gigabytes pe_start = 384 pe_count = 238466 # 931.508 Gigabytes } pv4 { id = "KZron2-pPTr-ZYeQ-PKXX-4Woq-6aNc-AG4rRJ" device = "/dev/md5" # Hint only status = ["ALLOCATABLE"] flags = [] dev_size = 3907028992 # 1.81935 Terabytes pe_start = 384 pe_count = 476932 # 1.81935 Terabytes } }

    Read the article

< Previous Page | 125 126 127 128 129 130 131 132 133 134 135 136  | Next Page >