Search Results

Search found 59241 results on 2370 pages for 'application mode'.

Page 13/2370 | < Previous Page | 9 10 11 12 13 14 15 16 17 18 19 20  | Next Page >

  • Deployed Web Application Requests for User Name and Password

    - by user43175
    Deployed Web Application Requests for User Name and Password I recently deployed a .NET web application into the server. Authentication mode is set to Windows (since the application is accessible only to Intranet users. Testing some machines, the application loads up properly. For some machines, a logon dialog window appears asking for User Name or Password. These dialog windows are those that you also normally see when you are trying to log into a Windows domain. Any idea why this happens randomly? Thanks.

    Read the article

  • Learning AngularJS by Example – The Customer Manager Application

    - by dwahlin
    I’m always tinkering around with different ideas and toward the beginning of 2013 decided to build a sample application using AngularJS that I call Customer Manager. It’s not exactly the most creative name or concept, but I wanted to build something that highlighted a lot of the different features offered by AngularJS and how they could be used together to build a full-featured app. One of the goals of the application was to ensure that it was approachable by people new to Angular since I’ve never found overly complex applications great for learning new concepts. The application initially started out small and was used in my AngularJS in 60-ish Minutes video on YouTube but has gradually had more and more features added to it and will continue to be enhanced over time. It’ll be used in a new “end-to-end” training course my company is working on for AngularjS as well as in some video courses that will be coming out. Here’s a quick look at what the application home page looks like: In this post I’m going to provide an overview about how the application is organized, back-end options that are available, and some of the features it demonstrates. I’ve already written about some of the features so if you’re interested check out the following posts: Building an AngularJS Modal Service Building a Custom AngularJS Unique Value Directive Using an AngularJS Factory to Interact with a RESTful Service Application Structure The structure of the application is shown to the right. The  homepage is index.html and is located at the root of the application folder. It defines where application views will be loaded using the ng-view directive and includes script references to AngularJS, AngularJS routing and animation scripts, plus a few others located in the Scripts folder and to custom application scripts located in the app folder. The app folder contains all of the key scripts used in the application. There are several techniques that can be used for organizing script files but after experimenting with several of them I decided that I prefer things in folders such as controllers, views, services, etc. Doing that helps me find things a lot faster and allows me to categorize files (such as controllers) by functionality. My recommendation is to go with whatever works best for you. Anyone who says, “You’re doing it wrong!” should be ignored. Contrary to what some people think, there is no “one right way” to organize scripts and other files. As long as the scripts make it down to the client properly (you’ll likely minify and concatenate them anyway to reduce bandwidth and minimize HTTP calls), the way you organize them is completely up to you. Here’s what I ended up doing for this application: Animation code for some custom animations is located in the animations folder. In addition to AngularJS animations (which are defined using CSS in Content/animations.css), it also animates the initial customer data load using a 3rd party script called GreenSock. Controllers are located in the controllers folder. Some of the controllers are placed in subfolders based upon the their functionality while others are placed at the root of the controllers folder since they’re more generic:   The directives folder contains the custom directives created for the application. The filters folder contains the custom filters created for the application that filter city/state and product information. The partials folder contains partial views. This includes things like modal dialogs used in the application. The services folder contains AngularJS factories and services used for various purposes in the application. Most of the scripts in this folder provide data functionality. The views folder contains the different views used in the application. Like the controllers folder, the views are organized into subfolders based on their functionality:   Back-End Services The Customer Manager application (grab it from Github) provides two different options on the back-end including ASP.NET Web API and Node.js. The ASP.NET Web API back-end uses Entity Framework for data access and stores data in SQL Server (LocalDb). The other option on the back-end is Node.js, Express, and MongoDB.   Using the ASP.NET Web API Back-End To run the application using ASP.NET Web API/SQL Server back-end open the .sln file at the root of the project in Visual Studio 2012 or higher (the free Express 2013 for Web version is fine). Press F5 and a browser will automatically launch and display the application. Using the Node.js Back-End To run the application using the Node.js/MongoDB back-end follow these steps: In the CustomerManager directory execute 'npm install' to install Express, MongoDB and Mongoose (package.json). Load sample data into MongoDB by performing the following steps: Execute 'mongod' to start the MongoDB daemon Navigate to the CustomerManager directory (the one that has initMongoCustData.js in it) then execute 'mongo' to start the MongoDB shell Enter the following in the mongo shell to load the seed files that handle seeding the database with initial data: use custmgr load("initMongoCustData.js") load("initMongoSettingsData.js") load("initMongoStateData.js") Start the Node/Express server by navigating to the CustomerManager/server directory and executing 'node app.js' View the application at http://localhost:3000 in your browser. Key Features The Customer Manager application certainly doesn’t cover every feature provided by AngularJS (as mentioned the intent was to keep it as simple as possible) but does provide insight into several key areas: Using factories and services as re-useable data services (see the app/services folder) Creating custom directives (see the app/directives folder) Custom paging (see app/views/customers/customers.html and app/controllers/customers/customersController.js) Custom filters (see app/filters) Showing custom modal dialogs with a re-useable service (see app/services/modalService.js) Making Ajax calls using a factory (see app/services/customersService.js) Using Breeze to retrieve and work with data (see app/services/customersBreezeService.js). Switch the application to use the Breeze factory by opening app/services.config.js and changing the useBreeze property to true. Intercepting HTTP requests to display a custom overlay during Ajax calls (see app/directives/wcOverlay.js) Custom animations using the GreenSock library (see app/animations/listAnimations.js) Creating custom AngularJS animations using CSS (see Content/animations.css) JavaScript patterns for defining controllers, services/factories, directives, filters, and more (see any JavaScript file in the app folder) Card View and List View display of data (see app/views/customers/customers.html and app/controllers/customers/customersController.js) Using AngularJS validation functionality (see app/views/customerEdit.html, app/controllers/customerEditController.js, and app/directives/wcUnique.js) More… Conclusion I’ll be enhancing the application even more over time and welcome contributions as well. Tony Quinn contributed the initial Node.js/MongoDB code which is very cool to have as a back-end option. Access the standard application here and a version that has custom routing in it here. Additional information about the custom routing can be found in this post.

    Read the article

  • How does the PPA fit into the scenario of publishing an application to the Ubuntu Software Center?

    - by Mridang Agarwalla
    I've been going through docs for the past couple of hours but I haven't understood what the PPA is? I have a cross-platform Java application that I'd like to publish to the Ubuntu Software Center. My application is open-source and I'm using Github. Apparently, publishing applications to the store isn't as simple as uploading a deb package - am I right? I need to create an account on Launchpad and put all my code there. I don't intend to move from Git to Bzr merely for the sake of publishing to the app store but luckily, one is able to set up source-code mirroring from Github to Launchpad. Since my application is still very premature, it'll have updates fairly often. When I build my application on my machine, do I simply go my Ubuntu App Developer page and upload the new DEB package or do they build my application from source? What exactly is the PPA for? I don't think I'll need too many of the Launchpad features so I'd like to stick to Github if possible. (Publishing for Ubuntu really isn't trivial. I can see why there are so many developers out there who haven't published their applications to the Ubuntu Software Center. Publishing an Android applications has been the easiest so far.)

    Read the article

  • Is it possible for an application (written in Mono C#) to run a console command?

    - by Razick
    I am wondering if a Mono C# application can somehow run a terminal command. For example, could the user give the program his or her password and then have the application run sudo apt-get install application-name (console requests password) password (console requests confirmation) y Preferably, this would be done without actually opening a terminal visible to the user, so that the application could provide the necessary feedback and manage the whole operation cleanly with as little user interaction as possible. Is there a way to do that? Let me know if clarification is needed. Thank you!

    Read the article

  • What is the best strategy for licensing a desktop application using a web service, when all I need to know is when people use the product?

    - by user1667022
    Our company's main application is a desktop program that is used at warehouses and written in C# and Windows Presentation Forms. The next thing we want to be able to do is track when customers open up the application and when it is being used. The reason for this is so we can charge them per month, based on if they are/arn't using the application. My boss is having me research different ways to "license" the product under these requirements. Not having any experience doing this, a few things come to mind. I could create a web application that runs on a server, and every time the desktop application is opened and the user logs in, the application connects to the server and marks a database with the DateTime. Or is there licensing software that I can use to accomplish this? Just looking for tips/advice from people who have experience with this type of stuff.

    Read the article

  • How to use Application Verifier to find memory leaks

    - by Patrick
    I want to find memory leaks in my application using standard utilities. Previously I used my own memory allocator, but other people (yes, you Neil) suggested to use Microsoft's Application Verifier, but I can't seem to get it to report my leaks. I have the following simple application: #include <iostream> #include <conio.h> class X { public: X::X() : m_value(123) {} private: int m_value; }; void main() { X *p1 = 0; X *p2 = 0; X *p3 = 0; p1 = new X(); p2 = new X(); p3 = new X(); delete p1; delete p3; } This test clearly contains a memory leak: p2 is new'd but not deleted. I build the executable using the following command lines: cl /c /EHsc /Zi /Od /MDd test.cpp link /debug test.obj I downloaded Application Verifier (4.0.0665) and enabled all checks. If I now run my test application I can see a log of it in Application Verifier, but I don't see the memory leak. Questions: Why doesn't Application Verifier report a leak? Or isn't Application Verifier really intended to find leaks? If it isn't which other tools are available to clearly report leaks at the end of the application (i.e. not by taking regular snapshots and comparing them since this is not possible in an application taking 1GB or more), including the call stack of the place of allocation (so not the simple leak reporting at the end of the CRT) If I don't find a decent utility, I still have to rely on my own memory manager (which does it perfectly).

    Read the article

  • Traditional ASP.NET application in subdirectory of an MVC application

    - by David
    Windows Server 2003, IIS6. We're trying to deploy a non-MVC ASP.NET web application as a subdirectory of an MVC application. However the ASP.NET application in the subdirectory is failing with the message "Could not load file or assembly 'System.Web.Mvc, Version=1.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find the file specified." which is bizarre because it's not an MVC application.

    Read the article

  • How to create a stand alone command line application with Node.js

    - by Fab
    I'm trying to find a way to use a command line nodejs application that I created on a computer without node.js installed. In other words how to package my application with node.js inside, in order to avoid the users to have node.js already installed. The tipical use case is: I run the application and the application works using the node core that is provide with the application (or the application checks if there is node.js installed, and if not it donwload and install it automatically). Do you have any idea?

    Read the article

  • WinInet Apps failing when Internet Explorer is set to Offline Mode

    - by Rick Strahl
    Ran into a nasty issue last week when all of a sudden many of my old applications that are using WinInet for HTTP access started failing. Specifically, the WinInet HttpSendRequest() call started failing with an error of 2, which when retrieving the error boils down to: WinInet Error 2: The system cannot find the file specified Now this error can pop up in many legitimate scenarios with WinInet such as when no Internet connection is available or the HTTP configuration (usually configured in Internet Explorer’s options) is misconfigured. The error typically means that the server in question cannot be found or more specifically an Internet connection can’t be established. In this case the problem started suddenly and was causing some of my own applications (old Visual FoxPro apps using my own wwHttp library) and all Adobe Air applications (which apparently uses WinInet for its basic HTTP stack) along with a few more oddball applications to fail instantly when trying to connect via HTTP. Most other applications – all of my installed browsers, email clients, various social network updaters all worked just fine. It seems it was only WinInet apps that were failing. Yet oddly Internet Explorer appeared to be working. So the problem seemed to be isolated to those ‘classic’ applications using WinInet. WinInet’s base configuration uses the Internet Explorer options dialog. To check this out I typically go to the Internet Explorer options and find the Connection tab, and check out the LAN Setup. Make sure there are no rogue proxy settings or configuration scripts that are invalid. Trying with Auto-configuration on and off also can often fix ‘real’ configuration errors. This time however this wasn’t a problem – nothing in the LAN configuration was set (all default). I also played with the Automatic detection of settings which also had no effect. I also tried to use Fiddler to see if that would tell me something. Fiddler has a few additional WinInet configuration options in its configuration. Running Fiddler and hitting an HTTP request using WinInet would never actually hit Fiddler – the failure would occur before WinInet ever fired up the HTTP connection to go through the Fiddler HTTP proxy. And the Culprit is: Internet Explorer’s Work Offline Option The culprit in this situation was Internet Explorer which at some point, unknown to me switched into Offline Mode and was then shut down: When this Offline mode is checked when IE is running *or* if IE gets shut down with this flag set, all applications using WinInet by default assume that it’s running in offline mode. Depending on your caching HTTP headers and whether the page was cached previously you may or may not get a response or an error. For an independent non-browser application this will be highly unpredictable and likely result in failures getting online – especially if the application forces requests to always reload by disabling HTTP caching (as I do on most of my dynamic HTTP clients). What makes this especially tricky is that even when IE is in offline mode in the browser, you can still browse around the Web *if* you have a connection. IE will try to load anything it has cached from the local cache, but as soon as you hit a URL that isn’t cached it will automatically try to access that URL and uncheck the Work Offline option. Conversely if you get knocked off the Internet and browse in IE 9, IE will automatically go into offline mode. I never explicitly set offline mode – it just automatically sets itself on and off depending on the connection. Problem is if you’re not using IE all the time (as I do – rarely and just for testing so usually a few commonly used URLs) and you left it in offline mode when you exit, offline mode stays set which results in the above head scratcher. Ack. This isn’t new behavior in IE 9 BTW – this behavior has always been there, but I think what’s different is that IE now automatically switches between online and offline modes without notifying you at all, so it’s hard to tell when you are offline. Fixing the Issue in your Code If you have an application that is using WinInet, there’s a WinInet option called INTERNET_OPTION_IGNORE_OFFLINE. I just checked this out in my own applications and Internet Explorer 9 and it works, but apparently it’s been broken for some older releases (I can’t confirm how far back though) – lots of posts seem to suggest the flag doesn’t work. However, in IE 9 at least it does seem to work if you call InternetSetOption before you call HttpOpenRequest with the Http Session handle. In FoxPro code I use: DECLARE INTEGER InternetSetOption ;    IN WININET.DLL ;    INTEGER HINTERNET,;    INTEGER dwFlags,;    INTEGER @dwValue,;    INTEGER cbSize lnOptionValue = 1   && BOOL TRUE pass by reference   *** Set needed SSL flags lnResult=InternetSetOption(this.hHttpSession,;    INTERNET_OPTION_IGNORE_OFFLINE ,;  && 77    @lnOptionValue ,4)   DECLARE INTEGER HttpOpenRequest ;    IN WININET.DLL ;    INTEGER hHTTPHandle,;    STRING lpzReqMethod,;    STRING lpzPage,;    STRING lpzVersion,;    STRING lpzReferer,;    STRING lpzAcceptTypes,;    INTEGER dwFlags,;    INTEGER dwContextw     hHTTPResult=HttpOpenRequest(THIS.hHttpsession,;    lcVerb,;    tcPage,;    NULL,NULL,NULL,;    INTERNET_FLAG_RELOAD + ;    IIF(THIS.lsecurelink,INTERNET_FLAG_SECURE,0) + ;    this.nHTTPServiceFlags,0) …  And this fixes the issue at least for IE 9… In my FoxPro wwHttp class I now call this by default to never get bitten by this again… This solves the problem permanently for my HTTP client. I never want to see offline operation in an HTTP client API – it’s just too unpredictable in handling errors and the last thing you want is getting unpredictably stale data. Problem solved but this behavior is – well ugly. But then that’s to be expected from an API that’s based on Internet Explorer, eh?© Rick Strahl, West Wind Technologies, 2005-2011Posted in HTTP  Windows  

    Read the article

  • How to Easily Put a Windows PC into Kiosk Mode With Assigned Access

    - by Chris Hoffman
    Windows 8.1′s Assigned Access feature allows you to easily lock a Windows PC to a single application, such as a web browser. This feature makes it easy for anyone to configure Windows 8.1 devices as point-of-sale or other kiosk systems. In the past, setting up a Windows PC in kiosk mode involved much more work, requiring the use of third-party software, group policy, or Linux distributions designed around kiosk mode. Assigned Access is available on Windows 8.1 RT, Windows 8.1 Professional, and Windows 8.1 Enterprise. The standard edition of Windows 8.1 doesn’t support Assigned Access. Create a User Account for Assigned Access Rather than turn your entire computer into a locked-down kiosk system, Assigned Access allows you to create a separate user account that can only launch a single app — such as a web browser. To set this up, you must be logged into Windows as a user with administrator permissions. First, open the PC settings app — swipe in from the right or press Windows Key + C to open the charms bar, tap Settings, and tap Change PC settings. In the PC settings app, select Accounts and select Other accounts. Use the Add an account button to create a new Windows account. Select  the “Sign in without a Microsoft account” option and select Local account to create a local user account. You could also create a Microsoft account, but you may not want to do this if you just want a locked-down account with only browser access. If you need to install apps from the Windows Store to use in Assigned Access mode, you’ll have to set up a Microsoft account instead of a local account. A local account will still allow you access to the preinstalled apps, such as Internet Explorer. You may want to create a user account with a blank password. This would make it simple for anyone to access kiosk mode, even if the system becomes locked or needs to be rebooted. The account will be created as a standard user account with limited permissions. Leave it as a standard user account — don’t make it an administrator account. Set Up Assigned Access Once you’ve created an account, you’ll first need to sign into it. If you don’t, you’ll see a “This account has no apps” message when trying to enable Assigned Access. Go back to the welcome screen, log in to the new account you created, and allow Windows to go through the first-time account setup process. If you want to use a non-default app in kiosk mode, install it while logged in as that user account. Once you’re done, log out of the other account, log back in as your administrator account, and go back to the Other accounts screen. Click the Set up an account for assigned access option to continue. Select the user account you created and select the app you want to limit the account to. For a web-based kiosk, this can be a web browser such as the Modern version of Internet Explorer. Businesses can also create their own Modern apps and set them to run in kiosk mode in this way. Note that Microsoft’s documentation says “web browsers are not good choices for assigned access” because they require more permissions than average Modern (or “Windows Store”) apps. However, if you want to provide a kiosk for web-browsing, using Assigned Access is a much better option than using Guest Mode and offering up a full Windows desktop. When you’re done, restart your PC and log in as the Assigned Access account. Windows will automatically open the app you chose and won’t allow a user to leave that app. Standard Windows 8 features like the charms bar, app switcher, and Start screen won’t appear. Pressing the Windows key once will do nothing. To sign out of Assigned Access mode, press the Windows key five times — quickly — while signed in. You’ll be sent back to the standard login screen. The account will actually still be logged in and the app will remain running — this method just “locks” the screen and allows another user to log in. Automatically Log Into Assigned Access Whenever your Windows device boots, you can log into the Assigned Access account and turn it into a kiosk system. While this isn’t ideal for all kiosk systems, you may want the device to automatically launch the specific app when it boots without requiring any login process. To do so, you’ll just need to have Windows automatically log into the Assigned Access account when it boots. This option is hidden and not available in the standard Control Panel. You’ll need to use the hidden netplwiz Control Panel tool to set up automatic login on boot. If you didn’t create a password for the user account, leave the Password field empty while configuring this. Security Considerations If you’re using this feature to turn a Windows 8.1 system into a kiosk and leaving it open to the public, remember to consider security. Anyone could come up to the system, press the Windows key five times, and try to log into your standard administrator user account. Ensure the administrator user account has a strong password so people won’t be able to get past the kiosk system’s limitations and tamper with the system. Even Windows 8′s detractors have to admit that it’s an ideal system for a touch-screen kiosk device, running either a browser or another specific application. Assigned Access finally makes this easy to set up on Windows systems in the real world — no IT experience, third-party software, or Linux distributions necessary.     

    Read the article

  • low speed web application, Server problem or Application

    - by Ashian
    Hi, I have a web application written by asp.net (c#) sql server 2005. we host it on 2 dedicated server ( IIS and SQL server ) From some month ago , in some days of week we have many reports about speed issue. we have some other application on this server using same database. when we have speed problem all aplication on these server have this problem, but applications on other server in same data center work correctly. ram and cpu usage are ok. how can I check that the problem related to internet connection or my application design? which parameters must be checked. Some other information In applications users can upload several files to server , each file up to 3 MB. we use a sql web admin application, on same server that has same problem, this is a standard application which work perfectly on other servers. Thanks

    Read the article

  • Loading the Cache from the Business Application Server

    - by ACShorten
    By default, the Web Application server will directly connect to the Database to load its cache at startup time. Customers, who implement the product installation in distributed mode, where the Web Application Server and Business Application Server are deployed separately, may wish to prevent the Web Application Server to connect to the database directly. Installation of the product in distributed mode was introduced in Oracle Utilities Application Framework V2.2. In the Advanced Web Application Server configuration, it is possible to set the Create Simple Web Application Context (WEBAPPCONTEXT) to true to force the Web Application Server to load its cache via the Business Application rather than direct loading. The value of false will retain the default behavior of allowing the Web Application Server to connect directly to the database at startup time to load the cache. The value of true will load the cache data via direct calls to the Business Application Server, which can cause a slight delay in the startup process to cater for the architecture load rather than the direct load. The impact of the settings is illustrated in the figure below:                             When setting this value to true, the following properties files should be manually removed prior to executing the product: $SPLEBASE/etc/conf/root/WEB-INF/classes/hibernate.properties $SPLEBASE/splapp/applications/root/WEB-INF/classes/hibernate.properties Note: For customers who are using a local installation, where the Web Application Server and Business Application Server are combined in the deployed server, it is recommended to set this parameter to false, the default, unless otherwise required. This facility is available for Oracle Utilities Application Framework V4.1 in Group Fix 3 (via Patch 11900153) and Patch 13538242 available from My Oracle Support.

    Read the article

  • org-mode schedule weekly event for a period.

    - by Hamza Yerlikaya
    I would like to use agenda to keep track of my classes, assuming i have a com 355 class every week from march to june, <2010-03-23 Tue 10:40-12:10 +1w> this works but it schedules it indefinitely if i use, <2010-03-23 Tue 10:40-12:10 +1w>-<2010-06-23> it gets scheduled for everyday from march to june, how can i schedule this once a week for a period of time?

    Read the article

  • HttpModule.Init - safely add HttpApplication.BeginRequest handler in IIS7 integrated mode

    - by Paul Smith
    My question is similar but not identical to: http://stackoverflow.com/questions/1123741/why-cant-my-host-softsyshosting-com-support-beginrequest-and-endrequest-event (I've also read the mvolo blog referenced therein) The goal is to successfully hook HttpApplication.BeginRequest in the IHttpModule.Init event (or anywhere internal to the module), using a normal HttpModule integrated via the system.webServer config, i.e. one that doesn't: invade Global.asax or override the HttpApplication (the module is intended to be self-contained & reusable, so e.g. I have a config like this): <system.webServer> <validation validateIntegratedModeConfiguration="false"/> <modules> <remove name="TheHttpModule" /> <add name="TheHttpModule" type="Company.HttpModules.TheHttpModule" preCondition="managedHandler" /> So far, any strategy I've tried to attach a listener to HttpApplication.BeginRequest results in one of two things, symptom 1 is that BeginRequest never fires, or symptom 2 is that the following exception gets thrown on all managed requests, and I cannot catch & handle it from user code: Stack Trace: [NullReferenceException: Object reference not set to an instance of an object.] System.Web.PipelineModuleStepContainer.GetEventCount(RequestNotification notification, Boolean isPostEvent) +30 System.Web.PipelineStepManager.ResumeSteps(Exception error) +1112 System.Web.HttpApplication.BeginProcessRequestNotification(HttpContext context, AsyncCallback cb) +113 System.Web.HttpRuntime.ProcessRequestNotificationPrivate(IIS7WorkerRequest wr, HttpContext context) +616 Commenting out app.BeginRequest += new EventHandler(this.OnBeginRequest) in Init stops the exception of course. Init does not reference the Context or Request objects at all. I have tried: Removed all references to HttpContext.Current anywhere in the project (still symptom 1) Tested removing all code from the body of my OnBeginRequest method, to ensure the problem wasn't internal to the method (= exception) Sniffing the stack trace and only calling app.BeginRequest+=... when if the stack isn't started by InitializeApplication (= BeginRequest not firing) Only calling app.BeginRequest+= on the second pass through Init (= BeginRequest not firing) Anyone know of a good approach? Is there some indirect strategy for hooking Application_Start within the module (seems unlikely)? Another event which a) one can hook from a module's constructor or Init method, and b) which is subsequently a safe place to attach BeginRequest event handlers? Thanks much

    Read the article

  • windows kernel mode IOCTL returns random results

    - by clyfe
    I use the following code to fetch PSTORAGE_HOTPLUG_INFO capabilities from disks via IOCTL in a minifilter driver, but the returning hotplugInfo structure has all the fields set to random nonzero values on subsequent executions. What am I doing wrong? RESULT: 00000014 0.00046322 IOCTL Volume Media Removable, 64 00000015 0.00046451 IOCTL Volume Media Hotplug 154 00000016 0.00046562 IOCTL Volume Device Hotplug 244 00000054 1020.44311523 IOCTL Volume Media Removable, 240 00000055 1020.44311523 IOCTL Volume Media Hotplug 102 00000056 1020.44311523 IOCTL Volume Device Hotplug 244 Sample code: //int SomeFunction(PFLT_VOLUME pFLTVolume) STORAGE_HOTPLUG_INFO storageHotplugInfo; KEVENT event; IO_STATUS_BLOCK ioStatus; PIRP pirp; PDEVICE_OBJECT deviceObject; PSTORAGE_HOTPLUG_INFO hotplugInfo; ASSERT(KeGetCurrentIrql() <= DISPATCH_LEVEL); status = FltGetDiskDeviceObject(pFLTVolume, &deviceObject); if(!NT_SUCCESS(status)){ DbgPrint("No Device for Volume\n"); return 0; } KeInitializeEvent(&event, NotificationEvent, FALSE); ASSERT(KeGetCurrentIrql() <= APC_LEVEL); pirp = IoBuildDeviceIoControlRequest( IOCTL_STORAGE_GET_HOTPLUG_INFO, deviceObject, NULL, 0, &storageHotplugInfo, sizeof(STORAGE_HOTPLUG_INFO), FALSE, &event, &ioStatus ); if(!pirp){ return 0; } ASSERT(KeGetCurrentIrql() <= DISPATCH_LEVEL); status = IoCallDriver(deviceObject, pirp); if (status == STATUS_PENDING) { status = KeWaitForSingleObject( &event, Executive, KernelMode, FALSE, NULL); } else { ioStatus.Status = status; } status = ioStatus.Status; hotplugInfo = (PSTORAGE_HOTPLUG_INFO) &pirp->AssociatedIrp.SystemBuffer; if(hotplugInfo->MediaRemovable){ DbgPrint("IOCTL Volume Media Removable, %d\n", hotplugInfo->MediaRemovable); } if(hotplugInfo->MediaHotplug){ DbgPrint("IOCTL Volume Media Hotplug %d\n", hotplugInfo->MediaHotplug); } if(hotplugInfo->DeviceHotplug){ DbgPrint("IOCTL Volume Device Hotplug %d\n", hotplugInfo->DeviceHotplug); } ObDereferenceObject(deviceObject);

    Read the article

  • Emacs auto-minor-mode based on extension

    - by vermiculus
    I found this question somewhat on the topic, but is there a way [in emacs] to set a minor mode (or a list thereof) based on extension? For example, it's pretty easy to find out that major modes can be manipulated like so (setq auto-mode-alist (cons '("\\.notes$" . text-mode) auto-mode-alist)) and what I'd ideally like to be able to do is (setq auto-minor-mode-alist (cons '("\\.notes$" . auto-fill-mode) auto-minor-mode-alist)) The accept answer of the linked question mentions hooks, specifically temp-buffer-setup-hook. To use this, you have to add a function to the hook like so (add-hook 'temp-buffer-setup-hook 'my-func-to-set-minor-mode) My question is two-fold: Is there an easier way to do this, similar to major modes? If not, how would one write the function for the hook? It needs to check the file path against a regular expression. If it matches, activate the desired mode (e.g. auto-fill-mode).

    Read the article

  • C#: Parallel forms, multithreading and "applications in application"

    - by Harry
    First, what I need is - n WebBrowser-s, each in its own window doing its own job. The user should be able to see them all, or just one of them (or none), and to execute commands on each one. There is a main form, without a browser, this one contains control panel for my application. The key feautre is, each browser logs on to secured web page and it needs to stay logged in as long as possible. Well, I've done it, but I'm afraid something is wrong with my approach. The question is: Is code below valid, or rather a nasty hack which can cause problems: internal class SessionList : List<Session> { public SessionList(Server main) { MyRecords.ForEach(record => { var st = new System.Threading.Thread((data) => { var s = new Session(main, data as MyRecord); this.Add(s); Application.Run(s); Application.ExitThread(); }); st.SetApartmentState(System.Threading.ApartmentState.STA); st.Start(record); }); } // some other uninteresting methods here... } What's going on here? Session inherits from Form, so it creates a form, puts WebBrowser into it, and has methods to operate on websites. WebBrowser requires to be run in STA thread, so we provide one for each browser. The most interesting part of it is Application.Run(s). It makes the newly created forms alive and interactive. The next Application.ExitThread() is called after browser window is closed and its controls disposed. Main application stays alive to perform the rest of the cleanup job. When user select "Exit" or "Shutdown" option - first the browser threads are ended, so Application.ExitThread() is called. It all works, but everywhere I can read about "main GUI thread" - and here - I've created many GUI threads. I handle communication between main form and my new forms (sessions) with thread-safe methods using Invoke(). It all works, so is it right or is it wrong? Is everything right with using Application.Run() more than once in one application? :) An ugly hack or a normal practice? This code dies if I start a WebBrowser from the session form thread. It beats me why. It works however if I start WebBrowser (by changing its Url property) from any other thread. I'd like to know more what is really happening in such application. But most of all - I'd like to know if my idea of "applications in application" is OK. I'm not sure what exactly does Application.Run() do. Without it forms created in new threads were dead unresponsive. How is it possible I can call Application.Run() many times? It seems to do exactly what it should, but it seems a little undocumented feature to me. I'm almost sure, that the crashes are caused by WebBrowser component itself (since it's not completely "managed" and "native"). But maybe it's something else.

    Read the article

  • Safe mode boot with no change on screen but ongoing hard disk activity - why?

    - by omatai
    I have a machine with a dying hard drive - bad sectors are starting to multiply :-( The first sign (24 hours ago) was that it had an unmountable boot volume. At this time, I tried booting to safe mode with command prompt, which worked, after which I rebooted normally and ran a chkdsk. It has since been working as well as I could expect, but slowly getting less reliable. So I scheduled another chkdsk on both partitions (C: - boot, D: - data), having freed up a lot of space on both partitions to give Windows a little more scope for repairs (hopefully?). I then rebooted. On reboot, it protested about the unmountable boot volume again, so I booted to safe mode. I got the same list of drivers loaded as yesterday, and then no change to the screen for the past 2 hours. However, I see a flickering hard drive indicator light - not always on, but seldom ever off. What is happening? Is the chkdsk that runs in safe mode one which produces nothing on the screen and so chkdsk could be doing its thing... or is Windows still trying (but failing) to boot into Safe Mode?

    Read the article

  • Second Monitor stays black/in power save mode

    - by Rob
    I'm using two Monitors, a Belinea o.display 1 (Recognized as a Rogen Tech Distribution Inc 20" by Ubuntu, but working fine) on the DVI-Output (connected via DVI-to-VGA-adapter) as my primary Monitor and a Dell 19" (Recognized correctly) on the HDMI-output (via HDMI-to-DVI adapter) as secondary monitor. The graphics controller is a GeForce 9500 GS. I'm running a fully updated Ubuntu 13.04 with nouveau 1:1.0.7-0ubuntu1. The problem is that the second monitor (Dell) never seems to come out of standby during boot: the screen stays black and the status led on the monitor stays orange (it's green when it's on). It is correctly recognized an the size of the desktop is set accordingly, it just stays black. Changing any setting via xrandr/arandr/etc. does nothing. The on-screen-menu of the monitor reports it to be in power save mode. When using the proprietary NVIDIA-Drivers, the second monitor works just find. But these drivers cause a lot of other problems on my system, so i would really like to avoid them. On Ubuntu 12.10 i had found a workaround: When moving the relative position of the second monitor slightly down and the up again, it would turn on and function normally: xrandr --output DVI-I-1 --mode 1680x1050 --pos 1280x0 --rotate normal --output HDMI-1 --mode 1280x1024 --pos 0x88 --rotate normal sleep 2 xrandr --output DVI-I-1 --mode 1680x1050 --pos 1280x0 --rotate normal --output HDMI-1 --mode 1280x1024 --pos 0x0 --rotate normal This workaround stop working after the update to 13.04, and now i'm looking for a new solution. Has anyone experienced something similarity? xrandr output: Screen 0: minimum 320 x 200, current 2960 x 1050, maximum 8192 x 8192 DVI-I-1 connected 1680x1050+0+0 (normal left inverted right x axis y axis) 433mm x 270mm 1680x1050 60.0*+ 1280x1024 75.0 60.0 1280x960 60.0 1152x864 75.0 1024x768 75.1 72.0 70.1 60.0 832x624 74.6 800x600 72.2 75.0 60.3 56.2 640x480 72.8 75.0 66.7 60.0 720x400 70.1 HDMI-1 connected 1280x1024+1680+0 (normal left inverted right x axis y axis) 376mm x 301mm 1280x1024 60.0*+ 75.0 1152x864 75.0 1024x768 75.1 60.0 800x600 75.0 60.3 640x480 75.0 60.0 720x400 70.1 lshw -c video: *-display Beschreibung: VGA compatible controller Produkt: G96 [GeForce 9500 GS] Hersteller: NVIDIA Corporation Physische ID: 0 Bus-Informationen: pci@0000:01:00.0 Version: a1 Breite: 64 bits Takt: 33MHz Fähigkeiten: pm msi pciexpress vga_controller bus_master cap_list rom Konfiguration: driver=nouveau latency=0 Ressourcen: irq:16 memory:fa000000-faffffff memory:d0000000-dfffffff memory:f8000000-f9ffffff ioport:df00(Größe=128) memory:fb000000-fb07ffff Thanks for your help!

    Read the article

  • ATI Radeon HD7000 Series (Laptop) - Switch Mode Between ATI & Intel Integrated GPU. Stuck on Boot Screen On Intel GPU Selection Mode

    - by Monkey Drone
    Laptop Specs: HP Pavilion G6-2020SE GPUs 1) ATI HD7000 Series 2) Intel Integrated OS Installed: x) Ubuntu 12.04 (64 bit) i) ATI Graphics Card Drivers Installed From AMD website. Note: Graphics Card Drivers are Working Fine in 3D Mode. It runs a little Hot as it should since its a GPU. Observation) AMD Catalyst Control Centre Lets me Choose If I want to run the system in HIGH-END (ATI GPU) OR Intel Integrated (Better battery life) While I am on High End GPU Choice, Ubuntu works fine. Problem) But when I switch to Intel Mode in the AMD CCC and reboot the Machine. Ubuntu goes into 'Low Graphics Mode'. The problem is not that it goes into low graphics mode, it is completely expected since I am no longer using the ATI GPU but the integrated Intel GPU. Problem starts with the 'Selection' of the options. During that screen, I have no mouse on the screen (even tried plugging in an external USB mouse) & No Keyboard functionality. Thus I am left completely disabled to choose any option and load into Ubuntu. The Only thing I can do is switch to a terminal and enable ATI GPU through command-line and Ubuntu works Fine again. Is it a bug that there is no mouse/keyboard available to me during the startup of Ubuntu when its launched in Low-Graphics Mode? Any suggestions on how to pass through that? My palms are sweating as I write this down because the ATI GPU is really heating up my laptop. I dont want to boot into Windows or keep it around any longer than necessary. Please advise with help and directions. Sincerely, MonkeyD Edit1: The Answer by Celso has helped me switch to Intel, thus giving me sufficient battery power. Kudos to Celso. Now I can at least use my laptop for the time being without having it burn hair off my skin. I am still looking for answer to my original question of, 'why is lightdm not working properly when I switch to Intel GPU using ATI HD7000 series official drivers provided by AMD'.

    Read the article

  • Calling a WPF Application and modify exposed properties?

    - by Justin
    I have a WPF Keyboard Application, it is developed in such a way that an application could call it and modify its properties to adapt the Keyboard to do what it needs to. Right now I have a file *.Keys.Set which tells the application (on open) to style itself according to that new style. I know this file could be passed as a command line argument into the application. That would not be a problem. My concern is, is there a way via a managed environment to change the properties of the executable as long as they are exposed properly, an example: 'Creates a new instance of the Keyboard Application Dim e_key as new WpfApplication("C:\egt\components\keyboard.exe") 'Sets the style path e_key.SetStylePath("c:\users\joe\apps\me\default.keys.set") e_key.Refresh() 'Applies the style e_key.HideMenu() 'Hides the menu e_key.ShowDeck("PIN") 'Shows the custom "deck" of keyboard keys the developer 'Created in the style application. ''work with events and response 'Clear the instance from memory e_key.close e_key.dispose e_key = nothing This would allow my application to become easily accessible to other Touch Screen Application Developers, allowing them to use my keyboard and keep the functionality they need. It seems like it might be possible because (name of executable).application shows all the exposed functions, properties, and values. I just have never done this before. Any help would be appreciated, thank you in advance.

    Read the article

  • What is the Oracle Utilities Application Framework?

    - by Anthony Shorten
    The Oracle Utilities Application Framework is a reusable, scalable and flexible java based framework which allows other products to be built, configured and implemented in a standard way. Note: Even though the Framework is built in java it can be integrated with COBOL based extensions for backward compatibility. When Oracle Utilities Customer Care & Billing was migrated from V1 to V2, it was decided that the technical aspects of that product be separated to allow for reuse and independence from technical issues. The idea was that all the technical aspects would be concentrated in this separate product (i.e. a framework) and allow all products using the framework to concentrate on delivering superior functionality. The product was named the Oracle Utilities Application Framework (oufw is the product code). The technical components are contained in the Oracle Utilities Application Framework which can be summarized as follows: Metadata - The Oracle Utilities Application Framework is responsible for defining and using the metadata to define the runtime behavior of the product. All the metadata definition and management is contained within the Oracle Utilities Application Framework. UI Management - The Oracle Utilities Application Framework is responsible for defining and rendering the pages and responsible for ensuring the pages are in the appropriate format for the locale. Integration - The Oracle Utilities Application Framework is responsible for providing the integration points to the architecture. Refer to the Oracle Utilities Application Framework Integration Overview for more details Tools - The Oracle Utilities Application Framework provides a common set of facilities and tools that can be used across all products. Technology - The Oracle Utilities Application Framework is responsible for all technology standards compliance, platform support and integration. There are a number of products from the Tax and Utilities Global Business Unit as well as from the Financial Services Global Business Unit that are built upon the Oracle Utilities Application Framework. These products require the Oracle Utilities Application Framework to be installed first and then the product itself installed onto the framework to complete the installation process. There are a number of key benefits that the Oracle Utilities Application Framework provides to these products: Common facilities - The Oracle Utilities Application Framework provides a standard set of technical facilities that mean that products can concentrate in the unique aspects of their markets rather than making technical decisions. Common methods of configuration - The Oracle Utilities Application Framework standardizes the technical configuration process for a product. Customers can effectively reuse the configuration process across products. Multi-lingual and Multi-platform - The Oracle Utilities Application Framework allows the products to be offered in more markets and across multiple platforms for maximized flexibility. Common methods of implementation - The Oracle Utilities Application Framework standardizes the technical aspects of a product implementation. Customers can effectively reuse the technical implementation process across products. Quicker adoption of new technologies - As new technologies and standards are identified as being important for the product line, they can be integrated centrally benefiting multiple products. Cross product reuse - As enhancements to the Oracle Utilities Application Framework are identified by a particular product, all products can potentially benefit from the enhancement. Note: Use of the Oracle Utilities Application Framework does not preclude the introduction of product specific technologies or facilities to satisfy market needs. The framework minimizes the need and assists in the quick integration of a new product specific piece of technology (if necessary). The Framework is not available as a product itself and is bundled with Tax and Utilities Global Business Unit prodicts. At the present time the following products are on the Framework: Oracle Utilities Customer Care And Billing (V2 and above) Oracle Enterprise Taxation Management (V2 and above) Oracle Utilities Business Intelligence (V2 and above) Oracle Utilities Mobile Workforice Management (V2 and above)

    Read the article

< Previous Page | 9 10 11 12 13 14 15 16 17 18 19 20  | Next Page >