Search Results

Search found 40212 results on 1609 pages for 'hardware id'.

Page 13/1609 | < Previous Page | 9 10 11 12 13 14 15 16 17 18 19 20  | Next Page >

  • Retrieve .Net Control ID in Javascript

    - by Vipin
    Originally posted on: http://geekswithblogs.net/Vipin/archive/2013/07/24/retrieve-.net-control-id-in-javascript.aspxIf you need to retrieve a client ID of an asp:net control in a javascript function, then you can use the below function - function $$(id, context) { var el = $("#" + id, context); if (el.length < 1) el = $("[id$=_" + id + "]", context); return el; }   var tempDotNetControl = 'aspTextTemporary';   var ClientSideID = $$(aspTextTemporary); Please bear in mind, this function is useful if you want to retrieve client ID of a different DotNet control based on some condition, otherwise if it’s always static then you can just use <%= aspTextTemporary.ClientID %>"

    Read the article

  • Identifying methods with a specified Id in D [migrated]

    - by Ekyo777
    I want to have specific methods with a specific pattern recognized at compile time and registered along with a specified id trough mixins in a parent class. ex.: take a method 'X' from a class with a predetermined id:5, what I want is that, in a mixin in a parent class, method X will be registered as a delegate with its id to be called later on by its id. What would be the best way to specify the Id considering I want the id to be of type int and only the specified methods to be registered? should I (if it is even possible) do it with a custom annotation pretty much like the @property but with an argument, like: @autoregister(id) void method(...) if it is possible to do it this way, an example or a link to the documentation on how to do it would be nice since I didn't find it in the documentation.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Hashes vs Numeric id's

    - by Karan Bhangui
    When creating a web application that some how displays the display of a unique identifier for a recurring entity (videos on YouTube, or book section on a site like mine), would it be better to use a uniform length identifier like a hash or the unique key of the item in the database (1, 2, 3, etc). Besides revealing a little, what I think is immaterial, information about the internals of your app, why would using a hash be better than just using the unique id? In short: Which is better to use as a publicly displayed unique identifier - a hash value, or a unique key from the database? Edit: I'm opening up this question again because Dmitriy brought up the good point of not tying down the naming to db specific property. Will this sort of tie down prevent me from optimizing/normalizing the database in the future? The platform uses php/python with ISAM /w MySQL.

    Read the article

  • django getting current user id

    - by dana
    hello, i have a mini app where users can login, view their profile, and follow each other. 'Follow' is a relation like a regular 'friend' relationship in virtual communities, but it is not necessarily reciprocal, meaning that one can follow a user, without the need that the user to be following back that person who follows him. my problem is: if i am a logged in user, and i navigate to a profile X, and push the button follow, how can i take the current profile id ?(current profile meaning the profile that I, the logged in user, am viewing right now.) the view: def follow(request): if request.method == 'POST': form = FollowForm(request.POST) if form.is_valid(): new_obj = form.save(commit=False) new_obj.initiated_by = request.user u = User.objects. what here? new_obj.follow = u new_obj.save() return HttpResponseRedirect('.') else: form = FollowForm() return render_to_response('followme/follow.html', { 'form': form, }, context_instance=RequestContext(request)) thanks in advance!

    Read the article

  • CryptGenRandom to generate asp.net session id

    - by DoDo
    Hi! does anyone have working example of CryptGenrRandom class to generate session id (need to use in my iis module). HCRYPTPROV hCryptProv; BYTE pbData[16]; if(CryptAcquireContext( &hCryptProv, NULL, NULL, PROV_RSA_FULL, CRYPT_VERIFYCONTEXT)) { if(CryptGenRandom(hCryptProv, 8, pbData)) { std::string s(( const char *) pbData); printf(s.c_str()); } else { MyHandleError("Error during CryptGenRandom."); } } else { MyHandleError("Error during CryptAcquireContext!\n"); } i tried this code but, its not working quite well (i get it from msdn) and this example don't work for me ( http://www.codeproject.com/KB/security/plaintextsessionkey.aspx ) so if anyone know how to generate sessionid using this class plz let me know tnx anyway!

    Read the article

  • jQuery create new div with ID?

    - by John
    Hello, I have form in my ASP.NET masterPage.master and if i click on submit it call some method from masterPage.master.cs file by ajax (i have it in update panel). But i want improve it with jQuery. So i have this: $('#submit').click(function () { $.ajax({ type: "POST", url: '<% Response.Write("~"+Request.Path); %>', beforeSend: function () { $(document.createElement('div')).width($('#formBox').width()) .height($('#formBox').height()) .css({ backgroundImage: 'url(/Static/Img/bc_overlay.png)', position: 'absolute', left: 0, top: 0, margin: "5px", textAlign: "center", color: "#000", display: "none" }) .append("<strong>Nacítám</strong><br /><img src='Static/Img/ajax-loader.gif' width='33px' height='33px' alt='loading' />") .fadeIn("slow") .prependTo($('#formBox')); $('#formBox').css('position', 'relative'); }, success: function () { } }); }); So if i click on submit, new div is creating (there is loading text and image, and cool opacity overlay), but how i give to this div some ID? Because i need use it in success: function () { } i need clear this box and write here some text (error or success).

    Read the article

  • How does an OS communicate with other hardware components?

    - by Jack
    How can a program running on a CPU (mostly OS) access other PC hardware? Such as Graphic card, HDD and so? From what I read, in DOS, this was done using BIOS calls, specifically the INT instruction. But, the INT instruction should only jump to the certain space in RAM. So how can some program stored in RAM access other computer hardware, when the CPU can only access RAM, and receive interrupts? Does Windows use INT instructions as well, or is there a new way to communicate with the hardware?

    Read the article

  • Accessing hardware via USB by proprietary windows software using Wine

    - by Carlos Eugenio Thompson Pinzón
    I have this proprietary software that access some hardware using USB. Over a year ago I tried to install it on a Ubuntu OS using Wine (the program is written for Windows). The UI seemed to work just fine but it had no access to the USB port. Back then I had to license a Windows copy in order to get the job done. Now, that Windows version we where using is deprecated and it is not longer available and available versions cost trice as much. So it is time to give Linux another try. How can I ensure that the USB is available for a Wine application? Neither the application nor the hardware install any driver, the app just pool all available USB drivers and make a handshake if it recognizes that the hardware is present. I want to minimize the test cases before abandoning Linux one more time. Update I've just tried again (with the hope an upgrade was made from last year), and it is not working. The proprietary windows app is not finding the hardware.

    Read the article

  • invitation: EMEA Hardware: Quarterly Partner Sales Update Roadshow

    - by mseika
    Dear Partner We are pleased to invite you to attend the first Oracle EMEA Hardware Quarterly Partner Sales Update Roadshow running in 10 different cities across EMEA. The 3 hour sales session will run in the afternoon in various locations. You can directly register under the "Register Now" button. Learn to Articulate the Oracle Hardware Business value proposition to your customers. Explain Oracle Hardware positioning versus the competition. Understand Oracle Hardware as best platform to run the complete Oracle-on-Oracle stack from Application to Disk Locations & Timings Date Country Location Timings 2nd July 2013   France  Paris 13.00 - 16.15 PM 2nd July 2013  Saudi Arabia  Riyadh 13.00 - 16.15 PM 4th July 2013  United Arab Emirates  Dubai 13.00 - 16.15 PM 8th July 2013  South Africa  Johannesburg 13.00 - 16.15 PM 9th July 2013  Germany  Frankfurt 14.00 - 17.15 PM 10th July 2013  Germany  Münich 14.00 - 17.15 PM 11th July 2013  Switzerland  Zürich 14.00 - 17.15 PM 15th July 2013  United Kingdom  Reading 13.00 - 16.15 PM 17th July 2013  Spain  Madrid 14.00 - 17.15 PM 18th July 2013  Italy  Milan 13.00 - 16.15 PM Price: FREE Find your location and book your seat here! We hope you will take maximum advantage of these great learning and networking opportunities and look forward to welcoming you to your nearest event! Best regards, Giuseppe FacchettiPartner Business Development Manager,Servers, Oracle EMEA Sasan MoaveniStorage Partner Sales Manager,Oracle EMEA

    Read the article

  • invitation: EMEA Hardware: Quarterly Partner Sales Update Roadshow

    - by mseika
    Dear Partner We are pleased to invite you to attend the first Oracle EMEA Hardware Quarterly Partner Sales Update Roadshow running in 10 different cities across EMEA. The 3 hour sales session will run in the afternoon in various locations. You can directly register under the "Register Now" button. Learn to Articulate the Oracle Hardware Business value proposition to your customers. Explain Oracle Hardware positioning versus the competition. Understand Oracle Hardware as best platform to run the complete Oracle-on-Oracle stack from Application to Disk Locations & Timings Date Country Location Timings 2nd July 2013   France  Paris 13.00 - 16.15 PM 2nd July 2013  Saudi Arabia  Riyadh 13.00 - 16.15 PM 4th July 2013  United Arab Emirates  Dubai 13.00 - 16.15 PM 8th July 2013  South Africa  Johannesburg 13.00 - 16.15 PM 9th July 2013  Germany  Frankfurt 14.00 - 17.15 PM 10th July 2013  Germany  Münich 14.00 - 17.15 PM 11th July 2013  Switzerland  Zürich 14.00 - 17.15 PM 15th July 2013  United Kingdom  Reading 13.00 - 16.15 PM 17th July 2013  Spain  Madrid 14.00 - 17.15 PM 18th July 2013  Italy  Milan 13.00 - 16.15 PM Price: FREE Find your location and book your seat here! We hope you will take maximum advantage of these great learning and networking opportunities and look forward to welcoming you to your nearest event! Best regards, Giuseppe FacchettiPartner Business Development Manager,Servers, Oracle EMEA Sasan MoaveniStorage Partner Sales Manager,Oracle EMEA

    Read the article

  • Need to find number of new unique ID numbers in a MySQL table

    - by Nicholas
    I have an iPhone app out there that "calls home" to my server every time a user uses it. On my server, I create a row in a MySQL table each time with the unique ID (similar to a serial number) aka UDID for the device, IP address, and other data. Table ClientLog columns: Time, UDID, etc, etc. What I'd like to know is the number of new devices (new unique UDIDs) on a given date. I.e. how many UDIDs were added to the table on a given date that don't appear before that date? Put plainly, this is the number of new users I gained that day. This is close, I think, but I'm not 100% there and not sure it's what I want... SELECT distinct UDID FROM ClientLog a WHERE NOT EXISTS ( SELECT * FROM ClientLog b WHERE a.UDID = b.UDID AND b.Time <= '2010-04-05 00:00:00' ) I think the number of rows returned is the new unique users after the given date, but I'm not sure. And I want to add to the statement to limit it to a date range (specify an upper bound as well).

    Read the article

  • JSF2: Re-render all components on page that have a given ID, without absolute paths

    - by tlind
    Is there any way in JSF 2.0/PrimeFaces of re-rendering all components (using the PrimeFaces update="id1 id2..." attribute or the <f:ajax render="..."/> tag) that have got a given ID, regardless of whether they are in the same form that contains the button triggering the AJAX re-render or not? For example, I want my button to re-render all sections on a page that visualize the user's current shopping basket. Right now, I always have to specify the absolute path to the components that I want to get updated, e.g. update=":header:basket :left-sidebar:menu:basket" which is rather impractical if the structure of the page changes (besides, I have not been able to figure out the correct path for one of these components). I already tried to implement a custom EL function like this, which traverses the component tree: update="{utilBean.findAllComponentsMatchingId('basket')}" but at the time that function is evaluated, apparently not the entire component tree has been set up as it doesn't contain the components I am looking for. How can I deal with this? There certainly must be an easy way of doing AJAX-based updates of sections of the page that are not part of the current <h:form>? Thanks!

    Read the article

  • wifi hardware switch doesn't work on a Dell 1018

    - by user42566
    I have a problem with my Dell 1018 Inspiron. I can't switch the wifi on, through the key on the keyboard. I think it's a driver problem since Ubuntu 11.10. This are the versions i tried: Ubuntu 10.04 / 10.10 It's possible to install the driver by hand: sudo add-apt-repository ppa:lexical/hwe-wireless sudo apt-get update sudo apt-get install rtl8192ce-dkms Ubuntu 11.04 It works out of the box Ubuntu 11.10 / 12.04 I haven’t found any solution for these versions. The "ppa:lexical/hwe-wireless" doesn't work for these versions. It says Can not find package rtl8192ce-dkms. The window of additional drivers is empty. So I can't install the driver. The wired network works good. Here is some information: 0: dell-wifi: Wireless LAN Soft blocked: no Hard blocked: no 1: phy0: Wireless LAN Soft blocked: no Hard blocked: yes sudo lshw -class network *-network description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:05:00.0 logical name: eth0 version: 05 serial: 5c:26:0a:0d:20:10 size: 10Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half firmware=rtl_nic/rtl8105e-1.fw latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:43 ioport:2000(size=256) memory:f0f2c000-f0f2cfff memory:f0f18000-f0f1bfff *-network description: Wireless interface product: RTL8188CE 802.11b/g/n WiFi Adapter vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:07:00.0 logical name: wlan0 version: 01 serial: 70:f1:a1:fe:15:bd width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=rtl8192ce driverversion=3.2.0-22-generic-pae firmware=N/A ip=192.168.1.76 latency=0 link=yes multicast=yes wireless=IEEE 802.11bgn resources: irq:17 ioport:3000(size=256) memory:f0100000-f0103fff mark@mark-Inspiron-1018:~$ mark@mark-Inspiron-1018:~$ sudo lspci -nn 00:00.0 Host bridge [0600]: Intel Corporation N10 Family DMI Bridge [8086:a010] 00:02.0 VGA compatible controller [0300]: Intel Corporation N10 Family Integrated Graphics Controller [8086:a011] 00:02.1 Display controller [0380]: Intel Corporation N10 Family Integrated Graphics Controller [8086:a012] 00:1b.0 Audio device [0403]: Intel Corporation N10/ICH 7 Family High Definition Audio Controller [8086:27d8] (rev 02) 00:1c.0 PCI bridge [0604]: Intel Corporation N10/ICH 7 Family PCI Express Port 1 [8086:27d0] (rev 02) 00:1c.1 PCI bridge [0604]: Intel Corporation N10/ICH 7 Family PCI Express Port 2 [8086:27d2] (rev 02) 00:1d.0 USB controller [0c03]: Intel Corporation N10/ICH 7 Family USB UHCI Controller #1 [8086:27c8] (rev 02) 00:1d.1 USB controller [0c03]: Intel Corporation N10/ICH 7 Family USB UHCI Controller #2 [8086:27c9] (rev 02) 00:1d.2 USB controller [0c03]: Intel Corporation N10/ICH 7 Family USB UHCI Controller #3 [8086:27ca] (rev 02) 00:1d.3 USB controller [0c03]: Intel Corporation N10/ICH 7 Family USB UHCI Controller #4 [8086:27cb] (rev 02) 00:1d.7 USB controller [0c03]: Intel Corporation N10/ICH 7 Family USB2 EHCI Controller [8086:27cc] (rev 02) 00:1e.0 PCI bridge [0604]: Intel Corporation 82801 Mobile PCI Bridge [8086:2448] (rev e2) 00:1f.0 ISA bridge [0601]: Intel Corporation NM10 Family LPC Controller [8086:27bc] (rev 02) 00:1f.2 SATA controller [0106]: Intel Corporation N10/ICH7 Family SATA Controller [AHCI mode] [8086:27c1] (rev 02) 00:1f.3 SMBus [0c05]: Intel Corporation N10/ICH 7 Family SMBus Controller [8086:27da] (rev 02) 05:00.0 Ethernet controller [0200]: Realtek Semiconductor Co., Ltd. RTL8101E/RTL8102E PCI Express Fast Ethernet controller [10ec:8136] (rev 05) 07:00.0 Network controller [0280]: Realtek Semiconductor Co., Ltd. RTL8188CE 802.11b/g/n WiFi Adapter [10ec:8176] (rev 01) mark@mark-Inspiron-1018:~$ mark@mark-Inspiron-1018:~$ lsusb Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 002: ID 174f:1127 Syntek mark@mark-Inspiron-1018:~$

    Read the article

  • HP Compaq 2510p wireless disabled by hardware switch

    - by mylovelyhorse
    I have an HP Compaq 2510p laptop running ubuntu 12.04 LTS. ubuntu reports that wireless is disabled by means of a hardware switch. There is a 'soft-key' button on the laptop to control the physical wireless hardware but this does not respond. There is no other button, slider, (fn)+ combination to control the physical wireless hardware. There is no BIOS function to disable wireless (and on XP - previous OS - wireless functioned fine). mike@ubuntu:~$ rfkill list all 0: brcmwl-0: Wireless LAN Soft blocked: no Hard blocked: yes 1: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: no Running rfkill unblock all doesn't change things and I can see no way to change use from 0: to 1: (if that's even possible - or desirable - in the first place). I have checked for additional drivers and the Broadcom proprietary wireless driver is already installed and has a green light. Essentially, I believe I need to make the HP 'soft-keys' work - or at least the wireless card toggle. Advice gratefully received. Cheers M

    Read the article

  • Recycle Old Hardware into a Showcase Table

    - by Jason Fitzpatrick
    If you have a plethora of old hardware laying around, especially motherboard and expansion cards, this obsolete-hardware-to-table hack is just the ticket for your office or geek cave. The table’s design is simple. They took a regular coffee table, affixed old mother boards to it and then, over the motherboards and elevated by acrylic standoffs, they put a heavy sheet of acrylic to serve as the table top. You could replicate the design with any sort of old hardware that is interesting to look at: memory modules your company is sending off to be recycled, old digital cameras, mechanisms from peripherals headed for the scrap heap, etc. Hit up the link below to see more photos of the table. Circuit Table [Chris Harrison] How to Make and Install an Electric Outlet in a Cabinet or DeskHow To Recover After Your Email Password Is CompromisedHow to Clean Your Filthy Keyboard in the Dishwasher (Without Ruining it)

    Read the article

  • Oracle lanza una comunidad específica para hardware

    - by Eloy M. Rodríguez
    Para aquellos que aún no lo conozcan, quiero presentarles un grupo de interés creado por la compañía en Facebook con el nombre de Oracle Hardware Social Media Hub con el fin de ofrecer un lugar de reunión en la red en el que encontrar a miles de expertos, clientes, partners y reconocidos líderes de Oracle para debatir y descubrir lo último de Oracle. Allí encontrará una pionera aplicación de preguntas y respuestas denominada Pregunte al Experto de Oracle, en donde podrá formular preguntas, aportar comentarios e incluso ser premiado por sus aportaciones especializadas con el título de líderes reconocidos. En el Hardware Hub se podrá, entre otras cosas: Obtener contenidos exclusivos, solamente para los miembros Compartir sus conocimientos y experiencias con una comunidad global Comunicarse con expertos de Oracle en un entorno informal Descubrir métodos innovadores para optimizar el rendimiento de su hardware Acceder a contenidos en su idioma, incluyendo información de eventos, Webcasts, informes técnicos y mucho más.

    Read the article

  • Referring to hardware/software in first-person? [closed]

    - by JYelton
    At my company, there is a habit for the engineers to refer to their respective hardware/firmware/software in the first-person as if the device they are responsible for is a manifestation of themselves. I'll give you an example: Hardware Engineer: "I don't receive the first byte, so I stay off." Software Engineer: "I'm sending you the first byte after the ack flag, so I thought you were getting it." Hardware Engineer: "No, you're not turning me on." It was this very example I overheard today that nearly had me giggling in fits. "You're not turning me on." Well, I should hope not! So, is it common practice for engineers to do this, or simply unprofessional? Any suggestions for changing this apparently bad habit?

    Read the article

  • Introducing the Hardware Sales Consultant (Presales) Team in Greece

    - by fboufis
    Hello World and welcome to the blog of the Oracle Hardware Presales Team in Athens.The team is responsible for a cluster of six (6) countries which includes Greece, Cyprus, Malta, The Former Yugoslav Republic of Macedonia, Albania and Kosovo.We handle the complete hardware & systems software portfolio, namely: Engineered Systems: Purpose-build and General-purpose solutions Servers: SPARC (M & T-Series) & x86 (X-Series) servers Operating Systems: Oracle Solaris & Oracle Linux Virtualization Technologies: Oracle VM, Solaris Zones & Dynamic Domains Storage: NAS (ZFSSA), SAN (Axiom) & Tape (StorageTek) Systems Software: High Availability (Solaris Cluster) & Systems Management (Ops Center) and a multitude of other products, all of which will be the main topic of our blog. We design and propose solutions based on these products and assist both customers and partners in integrating those solutions in existing datacenters.We will be happy to support you in your projects, provide information and discuss your business issues, so do not hesitate to contact us.Filippos Boufis – Oracle Hardware Principal Sales Consultant

    Read the article

  • New EMEA Partner Community for Hardware

    - by Julien Haye
    We are delighted to announce the availability of the EMEA HW partner community. The EMEA Partner Community for Hardware is the place where partners in Europe, Middle East and Africa can share experiences and best practices about selling and implementing Servers, Storage and Solaris based projects. You will also receive first-hand information from Oracle on products, training and tools that can help you better market, sell and implement your projects and services based on Oracle Hardware. If you are an individual  working for an Oracle partner and your job is selling, implementing or supporting Oracle Servers, Storage and Solaris projects in EMEA then this community is for you. For further information on the EMEA HW partner community and instructions on how to become a member please visit: www.oracle.com/partners/goto/hardware-emea

    Read the article

  • NEW EMEA Hardware Partner Community

    - by Cinzia Mascanzoni
    We are delighted to announce the availability of the EMEA HW partner community. The EMEA Partner Community for Hardware is the place where partners in Europe, Middle East and Africa can share experiences and best practices about selling and implementing Servers, Storage and Solaris based projects. You will also receive first-hand information from Oracle on products, training and tools that can help you better market, sell and implement your projects and services based on Oracle Hardware. If you are an individual  working for an Oracle partner or distributor and your job is selling, implementing or supporting Oracle Servers, Storage and Solaris projects in EMEA then this community is for you. For further information on the EMEA HW partner community and instructions on how to become member please visit: www.oracle.com/partners/goto/hardware-emea

    Read the article

  • returning correct multiTouch id

    - by Max
    I've spent countless hours on reading tutorials and looking at every question related to multiTouch from here and Stackoverflow. But I just cannot figure out how to do this correctly. I use a loop to get my pointerId, I dont see alot of people doing this but its the only way I've managed to get it somewhat working. I have two joysticks on my screen, one for moving and one for controlling my sprites rotation and the angle he shoots, like in Monster Shooter. Both these work fine. My problem is that when I Move my sprite at the same time as Im shooting, my touchingPoint for my movement is set to the touchingPoint of my shooting, since the x and y is higher on the touchingPoint of my shooting (moving-stick on left side of screen, shooting-stick on right side), my sprite speeds up, this creates an unwanted change in speed for my sprite. I will post my entire onTouch method here with some variable-changes to make it more understandable. Since I do not know where Im going wrong. public void update(MotionEvent event) { if (event == null && lastEvent == null) { return; } else if (event == null && lastEvent != null) { event = lastEvent; } else { lastEvent = event; } int pointerCount = event.getPointerCount(); for (int i = 0; i < pointerCount; i++) { int x = (int) event.getX(i); int y = (int) event.getY(i); int id = event.getPointerId(i); int action = event.getActionMasked(); int actionIndex = event.getActionIndex(); String actionString; switch (action) { case MotionEvent.ACTION_DOWN: actionString = "DOWN"; break; case MotionEvent.ACTION_UP: shooting=false; // when shooting is true, it shoots dragging=false; // when dragging is true, it moves actionString = "UP"; break; case MotionEvent.ACTION_POINTER_DOWN: actionString = "PNTR DOWN"; break; case MotionEvent.ACTION_POINTER_UP: shooting=false; dragging=false; actionString = "PNTR UP"; break; case MotionEvent.ACTION_CANCEL: shooting=false; dragging=false; actionString = "CANCEL"; break; case MotionEvent.ACTION_MOVE: try{ if((int) event.getX(id) > 0 && (int) event.getX(id) < touchingBox && (int) event.getY(id) > touchingBox && (int) event.getY(id) < view.getHeight()){ movingPoint.x = (int) event.getX(id); movingPoint.y = (int) event.getY(id); dragging = true; } else if((int) event.getX(id) > touchingBox && (int) event.getX(id) < view.getWidth() && (int) event.getY(id) > touchingBox && (int) event.getY(id) < view.getHeight()){ shootingPoint.x = (int) event.getX(id); shootingPoint.y = (int) event.getY(id); shooting=true; }else{ shooting=false; dragging=false; } }catch(Exception e){ } actionString = "MOVE"; break; default: actionString = ""; } Wouldnt post this much code if I wasnt at an absolute loss of what I'm doing wrong. I simply can not get a good understanding of how multiTouching works. basicly movingPoint changes for both my first and second finger. I bind it to a box, but aslong as I hold one finger within this box, it changes its value based on where my second finger touches. It moves in the right direction and nothing gives an error, the problem is the speed-change, its almost like it adds up the two touchingPoints.

    Read the article

  • Wireless hardware is not getting switched on in 12.04

    - by user89733
    I have recently installed ubuntu 12.04 in sony vaio VPCEH. And updated all the available updates through update manager. When i switch on the bluetooth/wireless (hardware switch), only the bluetooth is turning on. For wireless, it shows as "hardware disabled". P.S: It was working fine few days before. Suddenly It is not turning on. i just get an answer for this question while googling. just enter the following command in the terminal. "sudo rfkill unblock all" This will unblock all hardware ports. that's it!!!!!! :) It works,..

    Read the article

  • How do I troubleshoot hardware issues related to a computer freeze/crash?

    - by KronoS
    What are some common guidelines and issues related to hardware being the issue of a computer crash? What should I look for and how do I troubleshoot these problems? What are some tools that are useful in diagnosing these hardware related crashes? I am looking to be able to isolate the problematic device with specific tools and guidelines. For example if device X is causing system failure how do I go about diagnosing it?

    Read the article

  • Does the Acer Ferrari One support hardware assisted virtualization?

    - by cmeerw
    Does anyone know if the Acer Ferrari One supports hardware assisted virtualization (it should easy to find out by running Microsoft's Hardware-Assisted Virtualization Detection Tool on that machine). There is lot's of speculation around the web, but I haven't found a definitive answer yet (and would like to confirm that this feature will be working before buying one).

    Read the article

< Previous Page | 9 10 11 12 13 14 15 16 17 18 19 20  | Next Page >