Search Results

Search found 3559 results on 143 pages for 'winforms interop'.

Page 131/143 | < Previous Page | 127 128 129 130 131 132 133 134 135 136 137 138  | Next Page >

  • Can't step into stored procedure on remote SQL Server 2008

    - by abatishchev
    I have a domain installed on virtual Windows Server 2008 x64. SQL Server 2008 Express x64 is running in Windows Server 2008 x64 and client on Windows 7 RTM x86. Both are into the domain. I'm starting both Visual Studio 2008 and SQL Server Management Studio 2008 under domain admin user. This account is a member of group sysadmin on SQL Server. Server has firewall exceptions for both TCP and UDP on ports 135-139 and 1433-1434. Visual Studio 2008 Remote debugger services is started on server and Domain Admins group is allowed to debug, When I'm starting debugging of a query in SMS I'm getting this error: Failed to start debugger Error HRESULT E_FAIL has been returned from a call to a COM component. (mscorlib) Program Location: at System.Runtime.InteropServices.Marshal.ThrowExceptionForHRInternal(Int32 errorCode, IntPtr errorInfo) at Microsoft.SqlServer.Management.UI.VSIntegration.DebugSession.DebugCallbacks.OnSqlInitializeDebuggingEvent(ISqlInitializeDebuggingEvent sqlInitializeDebuggingEvent) at Microsoft.SqlServer.Management.UI.VSIntegration.DebugSession.DebugCallbacks.Microsoft.VisualStudio.Debugger.Interop.IDebugEventCallback2.Event(IDebugEngine2 debugEngine, IDebugProcess2 debugProcess, IDebugProgram2 debugProgram, IDebugThread2 debugThread, IDebugEvent2 debugEvent, Guid& riidEvent, UInt32 attribute) and Unable to access the SQL Server debugging interface. The Visual Studio debugger cannot connect to the remote computer. A firewall may be preventing communication via DCOM to the remote computer. Please see Help for assistance. and Unable to start program MSSSQL://server.mydomain.local/master/sys/=0 And when stepping-in into a stored procedure using VS I'm getting the first one and this: Exception from HRESULT: 0x89710016 What have I do?

    Read the article

  • VSTO Development - Key Improvements In VS2010 / .NET 4.0?

    - by dferraro
    Hi all, I am trying to make a case to my bosses on why we should use VS2010 for an upcoming Excel Workbook VSTO application. I haven't used VSTO before but have used VBA. With 2010 just around the corner, I wanted to read about the improvements made to see if it was worth using 2010 to develop this application. So far I have read 2 major improvements are ease of deployments and also debugging / com interop improvements ... I was just wondering if there was anything else I wasn't aware of, or if anyone here is actually developing in VSTO and has used 2010 and both 2008 and could help make a case / arm me with information. The main concern of my bosses is deploying .NET 4.0 runtime on the Citrix servers here... however it seems that with 3.5, we would have to deploy the VSTO runtime and PIA's, etc... So really wouldn't deployments be easier with 2010 because installing just the 4.0 runtime is better than having to install the 'VSTO Runtime' as well as PIA's, etc? Or is there something I'm missing here? Anyone here deploy VSTO app in an enterprise and can speak to this? Also - I'm trying to also fight to use C# over VB.NET for this app. Does anyone know any key reasons why (except for my bias on preference of syntax) it would be better to use C# over VB for this? Any key features lacking in VB VSTO development? I've read about the VSTO Power Tools, and one of them describes LINQ enalbment of the Excel Object Model classes - however it says 'a set of C# classes'... Does anyone know if they literally mean C# - so this would not work with VB.NET, or do they just mean the code is written in C#? Anyone ever used these power tools with VB? I am going to download & play with it now, but any help again is greatly appreciated Thanks very much for any information.

    Read the article

  • Retrieving the COM class factory for component error while generating word document

    - by TheDPQ
    Hello, I am trying to edit a word document from VB.NET using for the most part this code: How to automate Word from Visual Basic .NET to create a new document http://support.microsoft.com/kb/316383 It works fine on my machine but when i publish to the server i get the following error. Retrieving the COM class factory for component with CLSID {000209FF-0000-0000-C000-000000000046} failed due to the following error: 80070005. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.UnauthorizedAccessException: Retrieving the COM class factory for component with CLSID {000209FF-0000-0000-C000-000000000046} failed due to the following error: 80070005. The actual error happens when i try to just create a word application object Dim oWord As New Word.Application Using Visual Studio 2008 and VB.NET 3.5. I made a reference to the "Microsoft Word 10.0 Object Library" and i see Interop.Word.dll file in the bin directory. Using MS Office 2003 on development machine and Windows Server 2003 Still fairly new to .NET and don't have much knowledge about window server, but "UnauthorizedAccessException" sounds like a permission issue. I'm wondering if someone could point me in the right direction on what i might need to do to give my little application access to use word. Thank you so much for your time.

    Read the article

  • How to create basic Adobe Illustrator files programatically?

    - by Jonas Follesø
    I need to create a really basic Adobe Illustrator file on the clipboard that I can paste in Adobe Illustrator or Expression Design. I'm looking for code samples on how to programaticaly generate Adobe Illustrator Files, preferably from C# or some other .NET language (but at the moment any language goes). I have found the Adobe Illustrator 3 File Format documentation online but it's allot to digest for this simple scenario. I don't want to depend on the actual Adobe Illustrator program (COM interop for instance) to generate my documents. Must be pure code. The code is for an Expression Studio addin, and I need to be able to create something on the clipboard I can paste into Expression Design. After looking at the formats Expression Design puts on the clipboard when copying a basic shape I've concluded that ADOBE AI3 i the best one to use (the others are either rendered images, or cfXaml that you cannot paste INTO Design). So based on this I can't use SWG which would probably been easier. Another idea might be to use a PDF component as the AI and PDF format is supposed to be compatible? I'm also finding some references to a format called "Adobe Illustrator Clipboard Format" (AICB), but can't find allot of documentation about it.

    Read the article

  • HTML to RTF Converter for .NET

    - by nickyt
    I've already seen lots of posts on the site for RTF to HTML and some other posts talking about some HTML to RTF converters, but I'm really trying to get a full breakdown of what is considered the most widely used commercial product, open source product or if people recommend going home grown. Apologies if you consider this a duplicate question, but I'm trying to create a product matrix to see what is the most viable for our application. I also think this would be helpful for others. The converter would be used in an ASP.NET 2.0 application (we're upgrading to 3.5 shortly but still sticking with WebForms) using SQLServer 2005 (soon 2008) as the DB. From reading a few posts, SautinSoft appears to be popular as a commercial component. Are there other commercial components that you'd recommend for converting HTML to RTF? Price does matter, but even if it's a little on the expensive side, please list it. For open source, I read that OpenOffice.org can be run as a service so that it can convert files. However, this appears to be only Java based. I imagine, I'd need some kind of interop to use this? What .NET open source components, if any, are out there for converting HTML to RTF? For home grown, is an XSLT the way to go with XHTML? If so, what component do you recommend for generating XHTML? Otherwise, what other home grown avenuses do you recommend. Also, please note that I currently don't care so much about RTF to HTML. If a commercial component offers this and the price is still the same, fine, otherwise please don't mention it.

    Read the article

  • When programatically creating a new IIS web site, how can I add it to an existing application pool?

    - by Ian Robinson
    I have successfully automated the process of creating a new IIS website, however the code I've written doesn't care about application pools, it just gets added to DefaultAppPool. However I'd like to add this newly created site to an existing application pool. Here is the code I'm using to create the new website. var w3Svc = new DirectoryEntry(string.Format("IIS://{0}/w3svc", webserver)); var newsite = new object[] { serverComment, new object[] { serverBindings }, homeDirectory }; var websiteId = w3Svc.Invoke("CreateNewSite", newsite); site.Invoke("Start", null); site.CommitChanges(); <update Although this is not directly related to the question, here are some sample values being used above. This might help someone understand exactly what the code above is doing more easily. webServer: "localhost" serverComment: "testing.dev" serverBindings: ":80:testing.dev" homeDirectory: "c:\inetpub\wwwroot\testing\" </update If I know the name of the application pool that I'd like this web site to be in, how can I find it and add this site to it? <update 2 I've added the following based on Mark's answer below. var appPool = new DirectoryEntry(string.Format("IIS://{0}/w3svc/AppPools/{1}", webServer, appPoolName)); site.Properties["AppPoolId"].Value = appPool; I seem to have moved passed the "RPC" error message I was initially receiving. Now this is the error message I'm receiving: Error: System.Runtime.InteropServices.COMException (0x8000500C): Exception from HRESULT: 0x8000500C at System.DirectoryServices.Interop.UnsafeNativeMethods.IAds.PutEx(Int32 lnControlCode, String bstrName, Object vProp) at System.DirectoryServices.PropertyValueCollection.set_Value(Object value) at ProvisionIISWebsite.Query.CreateWebsite(String webServer, String serverComment, String serverBindings, String homeDirectory, String appPoolName) in C:\Users\irobinson\My Projects\ProvisionIISWebsite\Query.cs:line 104 at ProvisionIISWebsite.Query.Handle_GetData(EngineBase& caller, Boolean isSubQuery, String query, String filterField, String filterText, Debugger& debugWriter, Boolean isRendered, Int32 timeout, String customConnection) in C:\Users\irobinson\My Projects\ProvisionIISWebsite\Query.cs:line 36 </update 2

    Read the article

  • Issue with VS 2008 designer and usercontrol.

    - by Ram
    Hello, I have created a custom data grid control. I dragged it on windows form and set its properties like column and all & ran the project. It built successfully and I am able to view the grid control on the form. Now if i try to view that form in designer, I am getting following error.. Object reference not set to an instance of an object. Instances of this error (1) 1. Hide Call Stack at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.GetMemberTargetObject(XmlElementData xmlElementData, String& member) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.CreateAssignStatement(XmlElementData xmlElement) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.XmlElementData.get_CodeDomElement() at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.EndElement(String prefix, String name, String urn) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.Parse(XmlReader reader) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.ParseXml(String xmlStream, CodeStatementCollection statementCollection, String fileName, String methodName) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomParser.OnMethodPopulateStatements(Object sender, EventArgs e) at System.CodeDom.CodeMemberMethod.get_Statements() at System.ComponentModel.Design.Serialization.TypeCodeDomSerializer.Deserialize(IDesignerSerializationManager manager, CodeTypeDeclaration declaration) at System.ComponentModel.Design.Serialization.CodeDomDesignerLoader.PerformLoad(IDesignerSerializationManager manager) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomDesignerLoader.PerformLoad(IDesignerSerializationManager serializationManager) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomDesignerLoader.DeferredLoadHandler.Microsoft.VisualStudio.TextManager.Interop.IVsTextBufferDataEvents.OnLoadCompleted(Int32 fReload) If I ignore the exception, form appears blank with no sign of grid control on it. However I can see the code for the grid in the designer file. Any pointer on this would be a great help.

    Read the article

  • upgrading .NET application from MapPoint 2004 to 2009...

    - by Joshua
    I am in the process of upgrading a Visual Studio 2005 .NET (C#) application from it's integration with MapPoint 2004 to supporting MapPoint 2009. After a bit of searching and fiddling, I've generated new DLLs using "tldimp" and "aximp" and now have Interop.MapPoint.dll and AxInterop.MapPoint.dll and the namespaces seem to line up to the previous ones, so all the object definitions are available. However, I have lots of errors telling me that various properties do not exist, even though I go into the Object Browser, and they do seem to exist. Here is an example (there are dozens of similar errors)... axMappointControl1.ActiveMap.Altitude = 1000; That object initializes fine, as a MapPoint.Map object, which when I browse to in the Object Browser, I go to MapPoint and Map and under Map there are no properties but when I look deeper there is _Map80 and _Map90 and EACH of these has an Altitude property. Under Map it also lists "Base Types", which has _Map in it which also has all the referenced properties! Yet, I am getting the error: "MapPoint.Map' does not contain a definition for 'Altitude' Pretty much all the properties of both MapPoint.Map and MapPoint.Toolbars are doing this. Any ideas? Thank you! Joshua

    Read the article

  • error: unable to open database file, SQLiteException was unhandled

    - by rose
    My project has a reference to SQLite.Interop.066.dll and even after putting in the correct path to the SQLite database, the application is still unable to find it. A SQLiteException was unhandled is returned. SQLiteConnection conn = new SQLiteConnection(); //SQLiteDataAdapter da; SQLiteCommandBuilder cb; DataTable dt=new DataTable(); int row = 0; conn.ConnectionString = "Data Source=C:\\database\\info"; conn.Open(); DataRow dr = dt.NewRow(); dr["name"] = txtName.Text; dr["address"] = txtAddress.Text; dr["phone"] = txtPhone.Text; dr["position"] = txtPosition.Text; dt.Rows.Add(dr); da.Update(dt); row = dt.Rows.Count - 1; txtName.Text = dt.Rows[row]["name"].ToString(); txtAddress.Text = dt.Rows[row]["address"].ToString(); txtPhone.Text = dt.Rows[row]["phone"].ToString(); txtPosition.Text = dt.Rows[row]["position"].ToString(); da.Fill(dt); cb = new SQLiteCommandBuilder(da); conn.Dispose(); conn.Close(); The exception occur at line: conn.Open(); sorry for the mistake title error before...

    Read the article

  • Distinguishing between .NET exception types

    - by Swingline Rage
    For the love of all things holy, how do you distinguish between different "exception flavors" within the predefined .NET exception classes? For example, a piece of code might throw an XmlException under the following conditions: The root element of the document is NULL Invalid chars are in the document The document is too long All of these are thrown as XmlException objects and all of the internal "tell me more about this exception" fields (such as Exception.HResult, Exception.Data, etc.) are usually empty or null. That leaves Exception.Message as the only thing that allows you to distinguish among these exception types, and you can't really depend on it because, you guessed it, the Exception.Message string is glocabilized, and can change when the culture changes. At least that's my read on the documentation. Exception.HResult and Exception.Data are widely ignored across the .NET libraries. They are the red-headed stepchildren of the world's .NET error-handling code. And even assuming they weren't, the HRESULT type is still the worst, downright nastiest error code in the history of error codes. Why we are still looking at HRESULTs in 2010 is beyond me. I mean if you're doing Interop or P/Invoke that's one thing but... HRESULTs have no place in System.Exception. HRESULTs are a wart on the proboscis of System.Exception. But seriously, it means I have to set up a lot of detailed specific error-handling code in order to figure out the same information that should have been passed as part of the exception data. Exceptions are useless if they force you to work like this. What am I doing wrong?

    Read the article

  • Handling Digital ID/Signature in Outlook Add-in

    - by CoSteve
    I have a C# Outlook Add-In application (VS2005 and 2003 Outlook) that reads incoming emails and strips out the attachments and the email text body for future processing. Occasionally I'll get an email that contains a digital signature. The application will fail when I try to access the mailitem.body property, throwing the following exception: System.Runtime.InteropServices.COMException (0xAB404001): The operation failed. at Microsoft.Office.Interop.Outlook._MailItem.get_Body() at MyLib.MyApp.OutlookAddin.MailProcessor.ProcessMailItem(MailItem mailItem) I'm pretty sure it is the digital signature causing the problem because if I forward the email back to myself, it will strip off the original sender's digital signature and the add-in application will process the email without any problems. I'm not sure what to do. I need to process the email, so I can't just ignore it. Somehow getting the body of the original email without throwing an exception would be ideal. Or I guess if I can identify that there is a digital signature associated with the email, I could forward the email to myself, but that seems a little messy. Does anyone have any suggestions/fixes? Thanks for any help.

    Read the article

  • Referencing .NET Assembly in VB6 won't work

    - by dretzlaff17
    I wrote a .net assembly using c# to perform functions that will be used by both managed and unmanaged code. I have a VB6 project that now needs to use the assembly via COM. I created my .net assembly, made sure that ComVisible is set to true and that it is registered for COM interop via project properties. public class MyClass [ComVisible(true)] public string GetResponse() { return "Testing Response" } } I build the assembly and copied the file into a folder. TestInterop.dll I then run a batch file to register the assembly tool to register the object for COM. cd C:\Windows\Microsoft.NET\Framework\v4.0.30319\ regasm "c:\Program Files\TestApp\TestInterop.dll" /tlb:TestInterop.tlb I open a new VB6 application and reference TestInterop.dll In VB6 I write the following code and it compiles. Dim obj as TestInterop.MyClass Set obj = new TestInterop.MyClass Dim strTest as string strTest = obj.GetRespose() When I run the program it errors on the obj.GetResponse() line. Run-time error' -2147024894 (80070002'): Automation error The system cannot find the file specified Also, the intellesense does not work on obj. I had to type the GetResponse method. Is this normal? Does anyone have any clue what could be wrong or what steps I missed. Thanks!

    Read the article

  • STOP Application Pool Issue Programitically IIS7

    - by Sumit Kute
    In my application I needs to stop a application pool programmitically in IIS 7. I have created a local acccount and given him Administrative Priviledges. Here is the code Private static void StopApplication() { string serviceHostDeploymentType = "local"; if (serviceHostDeploymentType.Equals("local")) { WindowsIdentityImpersonate newIdentity = new WindowsIdentityImpersonate(); if (newIdentity.Impersonate("AccountName", Environment.MachineName, "Password")) { try { ServerManager serverManager = ServerManager.OpenRemote("Server"); string siteName = GetWebSiteNameById(serverManager, 1); Site parentWebsite = serverManager.Sites[siteName]; if (parentWebsite != null) { ApplicationPool apppool = serverManager.ApplicationPools["Application Pool Name"]; if (apppool != null) { apppool.Stop(); } } } finally { newIdentity.Undo(); } } } else { throw new ConfigurationErrorsException("..."); } } I am getting an error Access is denied. (Exception from HRESULT: 0x80070005 (E_ACCESSDENIED)). Stack Trace at Microsoft.Web.Administration.Interop.IAppHostMethodInstance.Execute() at Microsoft.Web.Administration.ConfigurationElement.ExecuteMethod(String methodName) at Microsoft.Web.Administration.ApplicationPool.Stop() at ServerManagerTesting.Form1.StopApplication() at ServerManagerTesting.Form1.button1_Click(Object sender, EventArgs e) at System.Windows.Forms.Control.OnClick(EventArgs e) at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent) at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.ButtonBase.WndProc(Message& m) at System.Windows.Forms.Button.WndProc(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) at System.Windows.Forms.NativeWindow.DebuggableCallback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg) at System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(Int32 dwComponentID, Int32 reason, Int32 pvLoopData) at System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context) at ServerManagerTesting.Program.Main() at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart()

    Read the article

  • SQL Compact error: Unable to load DLL 'sqlceme35.dll'. The specified module could not be found

    - by Ciaran Bruen
    Hi - I'm developing a Winforms application using Visual Studio 2008 C# that uses a SQL compact 3.5 database on the client. The client will most likely be 32 bit XP or Vista machines. I'm using a standard Windows Installer project that creates an msi file and setup.exe to install the app on a client machine. I'm new to SQL compact so I haven't had to distribute a client database like this before now. When I run the setup.exe (on new Windows XP 32 bit with SP2 and IE 7) it installs fine but when I run the app I get the error below: Unable to load DLL 'sqlceme35.dll'. The specified module could not be found I spent a few hours searching this error already but all I can find are issues relating to installing on 64 bit Windows, none relating to normal 32 bit that I'm using. The install app copies the all the dependant files that it found into the specified install directory, including the System.Data.SqlServerCe.dll file (assembly version 3.5.1.0). The database file is in a directory called 'data' off the application directory, and the connection string for it is <add name="Tickets.ieOutlet.Properties.Settings.TicketsLocalConnectionString" connectionString="Data Source=|DataDirectory|\data\TicketsLocal.sdf" providerName="Microsoft.SqlServerCe.Client.3.5" /> Some questions I have: should the app be able to find the dll if it's in the same directory i.e. local to the app, or do I need to install it in the GAC? (If so cam I use the Windows Installer to install a dll in the GAC?) is there anything else I need to distribute with the app in order to use a Sql Compact database? there are other dlls also such as MS interop for exporting data to Excel on the client. Do these need to be installed in the GAC or will locating them in the application directory suffice? TIA, Ciaran.

    Read the article

  • Can't write the SysWow64 value to registry with vbscript for Screensaver

    - by Valentein
    Scripts, registries, screen-savers, oh my! I'm trying to use a screen-saver on a Windows XP 64 bit machine which uses a .NET app which makes an interop call which relies on some x86 Shockwave Dlls (some Shockwave animation). Everything should be in the %systemroot%\WINNT\SysWOW64 directory. When the timeout for the screensaver occurs, the process should looks like this: Screensaver.scr - .NET app - shockwave animation. During installation I want a vbscript to my screen-saver file to copy the Screensaver.scr to the SysWow64 directory and then set the proper registry key to this file for Windows to launch the screen-saver. The code is something like this: Dim sScreenSaver, tScreenSaver sScreenSaver = "C:\SourceFiles\bin\ScreenSaver.scr" 'screensaver tScreenSaver = "C:\winnt\SysWOW64\" Set WshShell = WScript.CreateObject("WScript.Shell") 'script shell to run objects Set FSO = createobject("scripting.filesystemobject") 'file system object 'copy screensaver FSO.CopyFile sScreenSaver, tScreenSaver, True 'set screen saver Dim p1 p1 = "HKEY_CURRENT_USER\Control Panel\Desktop\" WshShell.RegWrite p1 & "SCRNSAVE.EXE", (tScreenSaver & "ScreenSaver.scr") After installation, I can verify the the Screensaver exists in the correct directory. (It actually seems to be in both the system32 and the sysWOW64 directories---whether that's the install script or something I did post-install I'm in the process of verifying.) However, the registry entry is not correct. In both the 32 and 64 bit regedit I see the HKCU\ControlPanel\Desktop\SCRNSAVE.EX is set to: C:\WINNT\system32\Screensaver.scr This isn't right. The screen-saver won't run from this directory. It only runs from SysWOW64. If I manually edit the registry with regedit to the correct SysWOW64 path everything works fine. Is this a problem with using the script or is this a Windows registry redirection, or filesystem redirection problem? You'd think this would be simple...

    Read the article

  • How to prepopulate an Outlook MailItem and avoiding a com Exception from the object model guard

    - by torrente
    Hi, I work for a company that develops a CRM tool and offers integration with MS Office(2003 & 2007) from windows XP to 7. (I'm working using Win7) My task is to call an Outlook instance (using C#) from this CRM tool when the user wants to send an email and prepopulate with data of the CRM tool (email, recipient, etc..) All of this already works just fine. The problem I'm having is that Outlook's "object model guard" is throwing com Exception (Operation aborted (Exception from HRESULT: 0x80004004 (E_ABORT))) the moment I try to read a protected value from the mailItem (such as mail.bodyHTML). Example Snippet: using MSOutlook = Microsoft.Office.Interop.Outlook; //untrusted Instance _outlook = new MSOutlook.Application(); MSOutlook.MailItem mail = (MSOutlook.MailItem)_outlook.CreateItem(MSOutlook.OlItemType.olMailItem); //this where the Exception occurs string outlookStdHTMLBody = mail.HTMLBody; I've done quite a bit of reading and know that my Outlook Instance (derived by using new Application) is considered untrusted and therefore the "omg" kicks in. I do have a workaround for development: I'm running VS2010 as Administrator and if I run Outlook as Administrator as well - all is good. I suppose this is due to them having the same integrity levels(high) and the UAC(?) is not complaining. But that just ain't the way to go for deployment. Now the question is: Is there a way to obtain a trusted instance of Outlook so that I can avoid this exception? I've already read that when developing an Office Add-In using VSTO one can obtain a trusted Instance from the OnComplete event and/or using "ThisAddin" But I "merely" want to start an outlook instance and preopulate it, and do not want to develop an Add-In since this is not the requirement. And to make it clear - I have no problem with pop ups informing the user that outlook is being accessed - I just want to get rid of the exception! So how can I get around this problem using code? Any help is highly appreciated! Thomas

    Read the article

  • 'License expired' error when dynamically generating Excel docs in ASP.NET

    - by Mac
    Anyone familiar with error below? When I run my webapp to generate a dynamic excel doc from my local machine it works fine but when the same piece of code is invoked on the server I get the below error. It seems like it's a permissions issues since it works on my machine but not the server but I don't know where to start in order to pinpoint the problem. Any guidance/help is greatly appreciated! Server Error in '/' Application. -------------------------------------------------------------------------------- This command is unavailable because the license to use this application has expired. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Runtime.InteropServices.COMException: This command is unavailable because the license to use this application has expired. Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Stack Trace: [COMException (0x800a03ec): This command is unavailable because the license to use this application has expired.] Microsoft.Office.Interop.Excel.Workbooks.Add(Object Template) +0 PaymentsReport.Page_Load(Object sender, EventArgs e) +70 System.Web.Util.CalliHelper.EventArgFunctionCaller(IntPtr fp, Object o, Object t, EventArgs e) +15 System.Web.Util.CalliEventHandlerDelegateProxy.Callback(Object sender, EventArgs e) +34 System.Web.UI.Control.OnLoad(EventArgs e) +99 System.Web.UI.Control.LoadRecursive() +47 System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +1061 Office/Excel is installed on the server and I can open/save excel docs on the server. Could it be the version of excel on the server vs. my local machine? If so how can I make sure I have the latest on the server?

    Read the article

  • How to implement two way binding between an ActiveX control and a WPF MVVM View Model

    - by Zamboni
    I have a WPF application implemented using the MVVM framework that uses an ActiveX control and I need to keep the WPF and ActiveX UI synchronised. So far I can update the ActiveX UI when I change the WPF UI using the code at the bottom of the question that I got from the article Hosting an ActiveX Control in WPF and this question. But I cannot update the WPF UI when I make a change in the ActiveX UI. I suspect that I need to fire the PropertyChanged event from my ActiveX control but I have no idea how to do this or if it is even possible. The ActiveX controls I have written are in VB6 and MFC as I am just prototying at this time for the eventual integration of VB6 ActiveX controls in a WPF contaner application. Here is a code snipet that indicates the work done so far: System.Windows.Forms.Integration.WindowsFormsHost host = new System.Windows.Forms.Integration.WindowsFormsHost(); // Create the ActiveX control. AxTEXTBOXActiveXLib.AxTEXTBOXActiveX axWmp = new AxTEXTBOXActiveXLib.AxTEXTBOXActiveX(); // Assign the ActiveX control as the host control's child. host.Child = axWmp; axWmp.DataBindings.Add(new System.Windows.Forms.Binding("ActiveXStatus", (MainWindowViewModel)this.DataContext, "ModelStatus", true, DataSourceUpdateMode.OnPropertyChanged )); // Add the interop host control to the Grid // control's collection of child controls. this.activexRow.Children.Add(host); How to implement two way binding between an ActiveX control and a WPF MVVM View Model?

    Read the article

  • RegAsm for Class Library Used in VB6 Application

    - by michael.lukatchik
    To be short and to the point, I've built a C# class library that is both COM-Visible and Registered for COM Interop. I've compiled the library, which resulted in the generation of .dll and .tlb files. I have another machine that's running a VB6 application. So, I copied the .dll and .tlb files over to C:/Windows/system32 folder on the machine. I then registered those files using the following: C:\Windows\Microsoft.NET\Framework\v2.0.50727\RegAsm C:\Windows\system32\TestClass.dll /tlb:TestClass.tlb After the files were registered successfully, I added a project reference to the Test.tlb file from inside my VB6 app, then I tried to invoke a method in my new referenced class like so: Dim myObject As TestNamespace.TestClass Set myObject = New TestNamespace.TestClass MsgBox (myObject.TestMethod()) It doesn't work, and I receive a -2147024894 Automation Error. I've read that I shouldn't install the dll into a private folder like system32. I should either be registering in the GAC or I should be registering in another location using the "/codebase" option: C:\Windows\Microsoft.NET\Framework\v2.0.50727\RegAsm C:\TestClass.dll /tlb:TestClass.tlb /codebase Is there any reason I shouldn't be using system32? Past devs that have worked on this project have placed assembly files used by this VB6 project into system32 and there haven't seemed to be any issues. When I register my dll in the system32 location, I get the Automation Error. When I register my dll in another location (i.e. C:/), the method call into my class library from VB6 works as expected. What gives? I should mention that we will NOT be using the GAC to register any DLL's. That's just the way it is. Any help is appreciated. Mike

    Read the article

  • Error while running RSpec test cases.

    - by alokswain
    Following is the error i receive while running test cases written using rpsec. The strange thing is the test were running fine until early yesterday. Can someone guide me towards a solution. I am new to RSpec and and using Rspec and rspec-rails as plugins in my app. and i have no clue to what went wrong. F:/Spritle/programs/ruby 1.86/lib/ruby/gems/1.8/gems/activesupport-2.3.5/lib/active_suppor t/dependencies.rb:105:in `const_missing': uninitialized constant Test::Unit::TestResult::TestResultFailureSupport (NameError) from F:/Spritle/programs/ruby 1.86/lib/ruby/gems/1.8/gems/test-unit-2.0.1/lib/test/unit/testresult.rb:28 from F:/Spritle/programs/ruby 1.86/lib/ruby/site_ruby/1.8/rubygems/custom_require. rb:31:in `gem_original_require' from F:/Spritle/programs/ruby 1.86/lib/ruby/site_ruby/1.8/rubygems/custom_require. rb:31:in `require' from F:/Spritle/programs/ruby 1.86/lib/ruby/gems/1.8/gems/activesupport-2.3.5/lib/ active_support/dependencies.rb:158:in `require' from F:/Spritle/projects/Evaluation/vendor/plugins/rspec/lib/spec/interop/test.rb: 34 from F:/Spritle/programs/ruby 1.86/lib/ruby/site_ruby/1.8/rubygems/custom_require. rb:31:in `gem_original_require' from F:/Spritle/programs/ruby 1.86/lib/ruby/site_ruby/1.8/rubygems/custom_require. rb:31:in `require' from F:/Spritle/programs/ruby 1.86/lib/ruby/gems/1.8/gems/activesupport-2.3.5/lib/ active_support/dependencies.rb:158:in `require' ... 15 levels... from F:/Spritle/projects/Evaluation/vendor/plugins/rspec/lib/spec/runner/example_g roup_runner.rb:14:in `load_files' from F:/Spritle/projects/Evaluation/vendor/plugins/rspec/lib/spec/runner/options.r b:133:in `run_examples' from F:/Spritle/projects/Evaluation/vendor/plugins/rspec/lib/spec/runner/command_l ine.rb:9:in `run' from F:/Spritle/projects/Evaluation/vendor/plugins/rspec/bin/spec:5 rake aborted! Command "F:/Spritle/programs/ruby 1.86/bin/ruby.exe" -I"lib" "F:/Spritle/projects/Evaluation/vendor/plugins/rspec/bin/spec" "spec/controllers/articles_controller_spec.rb" --option s "F:/Spritle/projects/Evaluation/spec/spec.opts" failed

    Read the article

  • VS 2008 designer and usercontrol.

    - by Ram
    Hello, I have created a custom data grid control. I dragged it on windows form and set its properties like column and all & ran the project. It built successfully and I am able to view the grid control on the form. Now if i try to view that form in designer, I am getting following error.. Object reference not set to an instance of an object. Instances of this error (1) 1. Hide Call Stack at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.GetMemberTargetObject(XmlElementData xmlElementData, String& member) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.CreateAssignStatement(XmlElementData xmlElement) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.XmlElementData.get_CodeDomElement() at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.EndElement(String prefix, String name, String urn) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.Parse(XmlReader reader) at Microsoft.VisualStudio.Design.Serialization.CodeDom.XML.CodeDomXmlProcessor.ParseXml(String xmlStream, CodeStatementCollection statementCollection, String fileName, String methodName) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomParser.OnMethodPopulateStatements(Object sender, EventArgs e) at System.CodeDom.CodeMemberMethod.get_Statements() at System.ComponentModel.Design.Serialization.TypeCodeDomSerializer.Deserialize(IDesignerSerializationManager manager, CodeTypeDeclaration declaration) at System.ComponentModel.Design.Serialization.CodeDomDesignerLoader.PerformLoad(IDesignerSerializationManager manager) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomDesignerLoader.PerformLoad(IDesignerSerializationManager serializationManager) at Microsoft.VisualStudio.Design.Serialization.CodeDom.VSCodeDomDesignerLoader.DeferredLoadHandler.Microsoft.VisualStudio.TextManager.Interop.IVsTextBufferDataEvents.OnLoadCompleted(Int32 fReload) If I ignore the exception, form appears blank with no sign of grid control on it. However I can see the code for the grid in the designer file. Any pointer on this would be a great help. I have customized grid for my custom requirements like I have added custom text box n all. I have defined 3 constructors public GridControl() public GridControl(IContainer container) protected GridControl(SerializationInfo info, StreamingContext context)

    Read the article

  • Using SDL Tridion 2011 Core Service to create Components programatically

    - by user1428019
    I have seen some of the questions/answers related to this topic here, however still I am not getting the suggestion which I want. So I am posting my question again here, and I would be thankful for your valuable time and answers. I would like to create “Component, Page, SG, Publication, Folders “ via programmatically in SDL Tridion Content Manager, and later on, I would like to add programmatically created components in Page and attach CT,PT for that page, and finally would like to publish the page programmatically. I have done these all the activities in SDL Tridion 2009 using TOM API (Interop DLL's), and I tried these activities in SDL Tridion 2011 using TOM.Net API. It was not working and later on I came to know that, TOM.Net API will not support these kinds of works and it is specifically only for Templates and Event System. And finally I came to know I have to go for Core services to do these kinds of stuffs. My Questions: When I create console application to create component programmatically using core service, what are the DLL’s I have to add as reference? Earlier, I have created the exe and ran in the TCM server, the exe created all the stuffs, can I used the same approach using core services too? Will it work? Is BC still available or Core Service replaced BC? (BC-Business Connector) Can anyone send some code snippet to create Component/Page (complete class file will be helpful to understand better) Thanks Jai

    Read the article

  • Getting DirectoryNotFoundException when trying to Connect to Device with CoreCon API

    - by ageektrapped
    I'm trying to use the CoreCon API in Visual Studio 2008 to programmatically launch device emulators. When I call device.Connect(), I inexplicably get a DirectoryNotFoundException. I get it if I try it in PowerShell or in C# Console Application. Here's the code I'm using: static void Main(string[] args) { DatastoreManager dm = new DatastoreManager(1033); Collection<Platform> platforms = dm.GetPlatforms(); foreach (var p in platforms) { Console.WriteLine("{0} {1}", p.Name, p.Id); } Platform platform = platforms[3]; Console.WriteLine("Selected {0}", platform.Name); Device device = platform.GetDevices()[0]; device.Connect(); Console.WriteLine("Device Connected"); SystemInfo info = device.GetSystemInfo(); Console.WriteLine("System OS Version:{0}.{1}.{2}", info.OSMajor, info.OSMinor, info.OSBuildNo); Console.ReadLine(); } My question: Does anyone know why I'm getting this error? I'm running this on WinXP 32-bit, plain jane Visual Studio 2008 Pro. I imagine it's some config issue since I can't do it from a Console app or PowerShell. Here's the stack trace as requested: System.IO.DirectoryNotFoundException was unhandled Message="The system cannot find the path specified.\r\n" Source="Device Connection Manager" StackTrace: at Microsoft.VisualStudio.DeviceConnectivity.Interop.ConManServerClass.ConnectDevice() at Microsoft.SmartDevice.Connectivity.Device.Connect() at ConsoleApplication1.Program.Main(String[] args) in C:\Documents and Settings\Thomas\Local Settings\Application Data\Temporary Projects\ConsoleApplication1\Program.cs:line 23 at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args) at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() InnerException:

    Read the article

  • Programmatically modifying a file on Windows Server 2008 (Web Ed.)

    - by Tom
    I have written a .NET 2008 application, incorporating Microsoft.Office.Interop.Excel, that modifies an existing Excel 2007 spreadsheet. It works perfectly on my WinXP development computer. When I upload the app to a Microsoft Web Server 2008, it opens the file and reads from the file, but when the app tries to save the file, it throws this exception: "System.Runtime.InteropServices.COMException (0x800A03EC): 'july2009.xlsx' is read-only. To save a copy, click OK, then give the workbook a new name in the Save As dialog box." The file is NOT read-only, nor is it opened by any other user or app. The app and the Excel file both reside on the D: (data-only) drive. My first instinct was to look at file permissions. When nothing else worked, I literally created a temporary Group, added EVERY user and security entity to it and granted the group full control of the entire D: drive. No luck. Then I tried manually elevating the permission by running my app as administrator. No luck. Finally, I copied the file to my XP development computer and ran the app there. Of course it worked perfectly. Can anyone please tell me how to give my program permission to edit a file on Server 2008? Thanks!

    Read the article

  • What's the compelling reason to upgrade to Visual Studio 2010 from VS2008?

    - by Cheeso
    Are there new features in Visual Studio 2010 that are must-haves? If so, which ones? For me, the big draws for VS2008 as compared to VS2005 were LINQ, .NET Framework multitargeting, WCF (REST + Syndication), and general devenv.exe reliability. Granted, some of these features are framework things, and not tool things. For the purposes of this discussion, I'm willing to combine them into one bucket. What is the list of must-have features for VS2010 versus VS2008? Are there any? I am particularly interested in C#. Update: I know how to google, so I can get the official list from Microsoft. I guess what I really wanted was, the assessment from people using it, as to which things are really notable. Microsoft went on for 3 pages about 2008/3.5 features, and many people sort of boiled it down to LINQ, and a few other things. What is that short list for VS2010? Summary so far, what people think is cool or compelling: Visual Studio engine multi-monitor support new extensibility model based on WPF, prettier and more usable new TFS stuff, incl automated test tools parallel debugging .NET Framework parallel extensions for .NET C# 4.0 generic variance optional and named params easier interop with non-managed environments, like COM or Javascript VB 10.0 collection and array literals / initializers automatic properties anonymous methods / statement lambdas I read up on these at Zander's blog. He described these and other features. Nobody on this list said anything about: Visual Studio engine F# support Javascript code-completion JQuery is now included UML better Sharepoint capabilities C++ moves to msbuild project files

    Read the article

< Previous Page | 127 128 129 130 131 132 133 134 135 136 137 138  | Next Page >