  • Archlinux/atheros WLAN configuration troubles

    - by GrinReaper
    I'm trying to config archlinux to use my wireless network adapter. It's quite troublesome. From what I've gathered, it's an atheros network adapter, using the ath5k driver/module... I can't get it to work; any ideas? Here's some of the output from my tinkering: # lspci | grep -i net 00:0a.0 Ethernet controller: nVidia corporation MCP67 Ethernet (reva2) 03:00.0 Ethernet controller: atheros communications inc. AR5001 Wireless Network Adapter (rev01) # lsusb ... Bus 004 Device 003: ID 03f0:17d Hewlett Packard Wireless (Bluetooth + WLAN Interface [Integrated Module] # ping -c 3 www.google.com ping: unknown host www.google.com #ping -c 3 8.8.8.8 ping: network is unreachable # lspci -v 03:00.0 Ethernet controller: atheros communications inc. AR5001 Wireless Network Adapter (rev01) ... Kernel driver in use: ath5k Kernel modules: ath5k # dmesg |grep ath5k registered as phy0 registered led device ath5k: atheros chip found PCI INT A disabled registered led device registered as phy1 # ip addr | sed '/^[0-9]/!d;s/: <.*$//' 1: lo 2: eth1 3: eth0 # ip link set <interface> up/down RNETLINK answers: Operation not possible due to RF-kill Also, is there a way to dump text from command-line to a text file so i can just copy pasta? Sorry, first time using a linux distro... EDIT: So I just tried this: I actually just did this twice. (I can't tell which setting is on/off for my wireless adapter. The lights are blue all the time now.) #rfkill list 0: hp-wifi: wireless lan softblocked: no hardblocked :yes 1: hp-bluetooth: bluetooth softblocked: no hardblocked :yes 3: phy1: wireless lan softblocked: no hardblocked :yes #rfkill list 0: hp-wifi: wireless lan softblocked: no hardblocked :no 1: hp-bluetooth: bluetooth softblocked: no hardblocked no 3: phy1: wireless lan softblocked: no hardblocked :yes 7: hci0: bluetooh 0: hp-wifi: wireless lan softblocked: no hardblocked :no I've dug around some other articles and it seems like ath5k is supposed to be preferable to madwifi, so should i be using madwifi? I'm 99% sure I disabled the hardblock (by turning it ON) but, as shown above, phy1 wireless lan is STILL hardblocked. What gives? Maybe I've made some more fundamental error in a basic config file? EDIT: I've fixed the hardblock. I've tried pinging www.google.com, but to no avail. I get: ping: unknown host www.google.com In the arch wiki: Edit /etc/hosts and add the same HOSTNAME you entered in /etc/rc.conf: 127.0.0.1 archlinux.domain.org localhost.localdomain localhost archlinux To my understanding, hostname is just a user-specified and based on preference(?) My /etc/rc.conf: HOSTNAME="gestalt" My /etc/hosts: 127.0.0.1 localhost.localdomain localhost gestalt but should it be the following? 120.0.0.1 localhost.domain.org localhost.localdomain localhost gestalt

    Read the article

  • Disabling RAID feature on HP Smart Array P400

    - by Arie K
    I'm planning to use ZFS on my system (HP ML370 G5, Smart Array P400, 8 SAS disk). I want ZFS to manage all disks individually, so it can utilize better scheduling (i.e. I want to use software RAID feature in ZFS). The problem is, I can't find a way to disable RAID feature on the RAID controller. Right now, the controller aggregates all of the disks into one big RAID-5 volume. So ZFS can't see individual disk. Is there any way to acomplish this setup?

    Read the article

  • RAID1 rebuild fails due to disk errors

    - by overlord_tm
    Quick info: Dell R410 with 2x500GB drives in RAID1 on H700 Adapter Recently one of drives in RAID1 array on server failed, lets call it Drive 0. RAID controller marked it as fault and put it offline. I replaced faulty disk with new one (same series and manufacturer, just bigger) and configured new disk as hot spare. Rebuild from Drive1 started immediately and after 1.5 hour I got message that Drive 1 failed. Server was unresponsive (kernel panic) and required reboot. Given that half hour before this error rebuild was at about 40%, I estimated that new drive is not in sync yet and tried to reboot just with Drive 1. RAID controller complained a bit about missing RAID arrays, but it found foreign RAID array on Drive 1 and I imported it. Server booted and it runs (from degraded RAID). Here is SMART data for disks. Drive 0 (the one that failed first) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 1 3 Spin_Up_Time POS--K 142 142 021 - 3866 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10432 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 112 106 000 - 31 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 198 000 - 3 And Drive 1 (the drive which was reported healthy from controller until rebuild was attempted) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 35 3 Spin_Up_Time POS--K 143 143 021 - 3841 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10455 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 114 105 000 - 29 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 3 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 In extended error logs from SMART I found: Drive 0 has only one error Error 1 [0] occurred at disk power-on lifetime: 10282 hours (428 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 18 00 00 00 6a 24 20 40 00 Error: IDNF at LBA = 0x006a2420 = 6956064 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 60 00 f8 00 00 00 6a 24 20 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 18 00 60 00 00 00 6a 24 00 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 80 00 58 00 00 00 6a 23 80 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 68 00 50 00 00 00 6a 23 18 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 10 00 10 00 00 00 6a 23 00 40 00 17d+20:25:18.104 WRITE FPDMA QUEUED But Drive 1 has 883 errors. I see only few last ones and all errors I can see look like this: Error 883 [18] occurred at disk power-on lifetime: 10454 hours (435 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 01 -- 51 00 80 00 00 39 97 19 c2 40 00 Error: AMNF at LBA = 0x399719c2 = 966203842 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:57.802 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:57.779 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:55.704 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:55.681 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:53.606 READ FPDMA QUEUED Given those errors, is there any way I can rebuild RAID back, or should I make backup, shutdown server, replace disks with new ones and restore it? What about if I dd faulty disk to new one from linux running on USB/CD? Also, if anyone have more experiences, what could be causes for those errors? Crappy controller or disks? Disks are about 1 year old, but it is pretty unbelievable to me that both would die within so short timespan.

    Read the article

  • Buildcraft Minecraft mod causing crashes, NVIDIA-304xx Linux Drivers, KDE

    - by wolfo9999
    All is perfect, 96 fps average. Until an item tries to enter a buildcraft pipe. Tekkit instantly crashes, no error dialog. I have no idea what logs to look at for information on the crash, or how to fix it. OpenGL is enabled in KDE, Driver package is nvidia-304xx lspci output: VGA compatible controller: NVIDIA Corporation GT218 [Quadro FX 380M] (rev a2) (prog-if 00 [VGA controller]) Subsystem: Hewlett-Packard Company Device 172b Flags: bus master, fast devsel, latency 0, IRQ 16 Memory at d2000000 (32-bit, non-prefetchable) [size=16M] Memory at c0000000 (64-bit, prefetchable) [size=256M] Memory at d0000000 (64-bit, prefetchable) [size=32M] I/O ports at 5000 [size=128] [virtual] Expansion ROM at d3080000 [disabled] [size=512K] Capabilities: <access denied> Kernel driver in use: nvidia

    Read the article

  • MP3 player no longer syncs after installing Sixaxis drivers

    - by zildjohn01
    I recently installed third-party drivers for the (Sony) PS3 controller on my friend's PC (Windows XP). I found out a few days later that his MP3 player (also Sony) is no longer recognized by Windows. He gets the "connect device" sound, and about 250ms later, the "disconnect device" sound. I figured the controller driver took over the Walkman's device ID, so I went through the registry and C:\Windows\inf removing all references to Sony's VID (054C), but I haven't had any luck. What would you do in this situation?

    Read the article

  • Unable to create context rendering error when run OpenGL application

    - by Rodnower
    Hello, I try to run Mesa gears example and I get following error: freeglut (./gears): Unable to create direct context rendering for window 'Gears' This may hurt performance. though the application runs successfully, but I guess that in future I will have much problems with productivity. I run Linux CentOS 5 on WMvare 7. Mesa's version is 6.5 Relevant output of lspci -v gives: 00:0f.0 VGA compatible controller: VMware SVGA II Adapter (prog-if 00 [VGA controller]) Subsystem: VMware SVGA II Adapter Flags: bus master, medium devsel, latency 64, IRQ 9 I/O ports at 10d0 [size=16] Memory at d0000000 (32-bit, non-prefetchable) [size=128M] Memory at d8000000 (32-bit, non-prefetchable) [size=8M] [virtual] Expansion ROM at 30000000 [disabled] [size=32K] Capabilities: [40] Vendor Specific Information Any one have idea? There is driver of vmvare for CentOS? Thank you for ahead.

    Read the article

  • Windows 2012 Server Hyper-V: Cannot see LAN

    - by Samuel
    I have one NIC on the machine loaded XP on the Hyper-V and had chosen the network as virtual switch. No LAN and no internet shows up on the client. Am I missing something? it used to work in 2008-R2. Details: One network card on machine (Qualcomm Atheros AR8131 PIC-E Gigabit Ethernet controller) The virtual machine hard disk is pointing to and existing XP-SP2 hard disk created using VPC 2007 The Virtual machine Network Adapter is setup as Virtual Switch to the real ethernet controller with Enable virtual LAN identification set to 2 (no other virtual machine is created in the system) After the virtual machine boots LAN shows empty in Control Panel Network Connections (this is XP client) and I also cannot access the internet. XP is showing activation prompt but as far as I know it should not disable the network! Virtual network switch is set to External

    Read the article

  • Bluetooth not seeing mouse (Fedora)

    - by Chris
    I have a Lenovo S10 'netbook' that I've installed Fedora 17 ("LXDE spin") on. So far pretty much everything works great, except, the on-board Bluetooth. lsusb shows the controller present (0a5c:2101 Broadcom Corp. Bluetooth Controller), hcitool dev shows hci0 present, but when I put my mouse ("Lenovo Bluetooth Laser Mouse," which works perfectly paired with a MacBook Pro, MacBook Air, Mac mini, and Lenovo SL500 (with a USB dongle; running Windows 7)) into pairing mode and run hcitool scan (reports "Scanning ..." and, without further information or error message, returns to the shell prompt), blueman-manager, or bluetooth-wizard (from the gnome-bluetooth package) and try to detect the mouse, I get nothing... Frustrating! Thanks anyone who can point me in the right direction!

    Read the article

  • How to install Microsoft Exchange 2007 as a member server

    - by O_O
    I am trying to install Microsoft Exchange 2007 to a Windows Server 2003 as a member server. I already have a Windows Server 2008 as my domain controller. I'm having a hard time figuring out what is needed to prepare the machine for Exchange 2007 installation. My specific question is: While following the procedures here in the TechNet Library , do I still need to go through with the section "How to Prepare Active Directory and Domains" and do the following commands if I am making it a member server and NOT a domain controller? ie.. setup /ps setup /p /on: setup /PrepareDomain: Thank you.

    Read the article

  • How to use iSCSI inside HyperV VM?

    - by William
    I have 2 Dell R710 servers (intended to set up HyperV cluster) and a MD3000i SAN set up: Server1/Server2: NIC 1: connected to company LAN NIC 2: crossover to the other server's NIC 2 NIC 3: crossover to iSCSI port of SAN controller 1 NIC 4: crossover to iSCSI port of SAN controller 2 I have both servers setup as diskless servers with iSCSI boot from SAN without problem. But how can I access iSCSI from within the VM such that I can set up clustering inbetween the VMs? I can ping from the host to the SAN but found that NIC3/4 cannot be used for virtual network in HyperV? What am I doing wrong?

    Read the article

  • Unable to create context rendering error whet run OpenGL application

    - by Rodnower
    Hello, I try to run Mesa gears example and I get following error: freeglut (./gears): Unable to create direct context rendering for window 'Gears' This may hurt performance. though the application runs successfully, but I guess that in future I will have much problems with productivity. I run Linux CentOS 5 on WMvare 7. Mesa's version is 6.5 Relevant output of lspci -v gives: 00:0f.0 VGA compatible controller: VMware SVGA II Adapter (prog-if 00 [VGA controller]) Subsystem: VMware SVGA II Adapter Flags: bus master, medium devsel, latency 64, IRQ 9 I/O ports at 10d0 [size=16] Memory at d0000000 (32-bit, non-prefetchable) [size=128M] Memory at d8000000 (32-bit, non-prefetchable) [size=8M] [virtual] Expansion ROM at 30000000 [disabled] [size=32K] Capabilities: [40] Vendor Specific Information Any one have idea? There is driver of vmvare for CentOS? Thank you for ahead.

    Read the article

  • SAN cache memory upgrade

    - by Scott Lundberg
    We currently have an IBM DS4300 Dual Controller Fibre SAN. It is a good box, but getting pretty old. It came with 256MB of cache per controller. Recently we replaced the batteries in one of the controllers and noticed that the cache is a DDR PC2100 ECC DIMM. Of course, we are thinking about how cheap this RAM is now and is there any good reason we can't upgrade the RAM. IBM used to have a "Turbo" upgrade to this box that doubled the cache and had a bunch of software features for about 10K USD. Since that product has been end-of-lifed, I don't think we can get that upgrade and we don't need the software upgrades (FlashCopy, StorageCopy, etc). Besides the obvious potential warranty issue, what if any issues would we expect to see if attempting to put 2 - 1GB DIMMS in this unit? Any other things I am missing here? EDIT: Memory label: Samsung CN 0433 PC2100U-25331-A1 M381L3223ETM-CB0 256MB DDR PC2100 CL2.5 ECC

    Read the article

  • Linux Bluetooth [closed]

    - by Chris
    Not sure if this is the proper forum; please forgive me if it's not... I have a Lenovo S10 'netbook' that I've installed Fedora 17 ("LXDE spin") on. So far pretty much everything works great, except, the on-board Bluetooth. lsusb shows the controller present (0a5c:2101 Broadcom Corp. Bluetooth Controller), hcitool dev shows hci0 present, but when I put my mouse ("Lenovo Bluetooth Laser Mouse," which works perfectly paired with a MacBook Pro, MacBook Air, Mac mini, and Lenovo SL500 (with a USB dongle; running Windows 7)) into pairing mode and run either hcitool scan (reports "Scanning ..." and, without further information or error message, returns to the shell prompt) or bluetooth-wizard (from the gnome-bluetooth package) and try to detect the mouse, I get nothing... Frustrating! Thanks anyone who can point me in the right direction!

    Read the article

  • What will happen with my RAID5 after motherboard change?

    - by abatishchev
    Currently I have ASUS P5Q-EM and 3 HDD in RAID5 using it's on-board RAID controller Intel ICH10R. I want to bye a new motherboard, for example, Gigabyte GA-EQ45M-S2 which also have on-board RAID controller, but Intel ICH10DO. What will happen with my data on RAID5? Will I have to re-create the array from the scratch and lost all my data? Is such array a soft RAID or soft-hard? What if my current motherboard will broken? What will happen with my data?

    Read the article

  • KVM Guest installed from console. But how to get to the guest's console?

    - by badbishop
    I'm trying to install a fully virtualized guest (Fedora 14 x86_64) on KVM (RHEL 6), using command-line only (both hypervisor and guest). It goes without errors, and without a tangible result . I'd like to know how to do a text-only installation. So, here's what I've done: # virt-install \ --name=FE --ram=756 --vcpus=1 \ --file=/var/lib/libvirt/images/FE.img --network bridge:br0 \ --nographics --os-type=linux \ --extra-args='console=tty0' -v \ --cdrom=/media/usb/Fedora-14-x86_64-Live-Desktop.iso Starting install... Creating domain... | 0 B 00:00 Connected to domain FE Escape character is ^] ÿ Now what? As I understand after googling for a couple of days, I should see the guest's output from the text installation, but nothing happens. virt-viewer cannot connect to it, kindly suggesting that I explore all the options by adding --help (which I did). If I reconnect with virsh, I see this: Domain installation still in progress. You can reconnect to the console to complete the installation process. [root@v ~] # virsh console FEConnected to domain FE Escape character is ^] This shows that VM is running # virsh list Id Name State ---------------------------------- 8 FE running Qemu log: LC_ALL=C PATH=/sbin:/usr/sbin:/bin:/usr/bin /usr/libexec/qemu-kvm -S -M rhel6.0.0 -enable-kvm -m 756 -smp 1,sockets=1,cores=1,threads=1 -name FE -uuid 6989d008-7c89-424c-d2d3-f41235c57a18 -nographic -nodefconfig -nodefaults -chardev socket,id=monitor,path=/var/lib/libvirt/qemu/FE.monitor,server,nowait -mon chardev=monitor,mode=control -rtc base=utc -no-reboot -boot d -drive file=/var/lib/libvirt/images/FE.img,if=none,id=drive-ide0-0-0,format=raw,cache=none -device ide-drive,bus=ide.0,unit=0,drive=drive-ide0-0-0,id=ide0-0-0 -drive file=/media/usb/Fedora-14-x86_64-Live-Desktop.iso,if=none,media=cdrom,id=drive-ide0-1-0,readonly=on,format=raw -device ide-drive,bus=ide.1,unit=0,drive=drive-ide0-1-0,id=ide0-1-0 -netdev tap,fd=20,id=hostnet0 -device rtl8139,netdev=hostnet0,id=net0,mac=52:54:00:0a:65:8d,bus=pci.0,addr=0x2 -chardev pty,id=serial0 -device isa-serial,chardev=serial0 -usb -device virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x3 char device redirected to /dev/pts/1 Output of /etc/libvirt/qemu/FE.xml # cat /etc/libvirt/qemu/FE.xml <domain type='kvm'> <name>FE</name> <uuid>6989d008-7c89-424c-d2d3-f41235c57a18</uuid> <memory>774144</memory> <currentMemory>774144</currentMemory> <vcpu>1</vcpu> <os> <type arch='x86_64' machine='rhel6.0.0'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> <apic/> <pae/> </features> <clock offset='utc'/> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/libexec/qemu-kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='raw' cache='none'/> <source file='/var/lib/libvirt/images/FE.img'/> <target dev='hda' bus='ide'/> <address type='drive' controller='0' bus='0' unit='0'/> </disk> <disk type='block' device='cdrom'> <driver name='qemu' type='raw'/> <target dev='hdc' bus='ide'/> <readonly/> <address type='drive' controller='0' bus='1' unit='0'/> </disk> <controller type='ide' index='0'> <address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x1'/> </controller> <interface type='bridge'> <mac address='52:54:00:0a:65:8d'/> <source bridge='br0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/> </interface> <serial type='pty'> <target port='0'/> </serial> <console type='pty'> <target port='0'/> </console> <memballoon model='virtio'> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </memballoon> </devices> </domain> I'm obviously missing something that many others don't, but what is it? Thanx in advance!

    Read the article

  • Error setting up Data Protection Manager 2010 Agents / Network "Unauthenticated" in network settings

    - by Bowsa
    I'm not sure if the two are connected but i suspect they are. Basically I'm tring to setup Data Protection Manager 2010 on a fresh install of Server 2008 R2 in a SBS 2003 domain. Everything went fine until trying to install agents across the network. Upon clicking add, i get the following error message: Unable to connect to the Active Directory Domain Services Database. Make sure that the DPM server is a member of a domain and that the controller is running. Also verify that there is network connectivity between the DPM server and the domain controller. ID: 7 As usual (worryingly) the MSDN support for 2010 products is nearly non existant, clicking the error ID simply gives a page not found error. So after 2 days of Googling and trying various fixes (DNS settings, adding permissions to GPO objects, rejoining the domain and many more) I thought I'd ask here in the hope that someone out there may have had this issue before. Any help greatly appreciated!

    Read the article

  • Remotely managing Hyper-V VMs from Windows 8 Client

    - by Vazgen
    Currently, I have a core Hyper-V Server hosting VMs for a domain controller and several domain-joined VDI infrastructure servers. The VMs are connected in that domain environment, but the remote management of the physical Hyper-V Server is set up using the same WORKGROUP (as the Windows 8 client I'm managing from) This makes it cumbersome to manage the VMs hosted on the physical server from my remote management Windows 8 client because I can only connect to the physical Hyper-V server and not the individual VMs hosted inside. Can I make my set up more flexible by hosting a second domain controller in a VM hosted on my Windows 8 machine and switching my remote management set up to use the same domain through? Meaning ALL physical and virtual machines including the VDI infrastructure under the same domain? I'm new to this just looking for some suggestions.

    Read the article

  • Windows Server 2003 Synchronize Not Sticking

    - by lkessler
    We have a Windows Server 2003. It had Raid running on 2 disks. One disk failed and the Raid Controller failed. We replaced the disk and controller and restored everything. No data was lost. The users of that server found that there were a number of directories that appeared empty. We found that from their machine, we could right-click on the directory and select "Synchronize" and the files in the directory would now be visible to them. However, when opening Internet Explorer and browsing the web and ftp'ing to a web site, the files in the directory would vanish. We would have to "Synchronize" them again to get them to reappear. What is going on to cause this need to Synchronize and then re-Synchronize again? What do we need to do to fix this so that the directories are permanently visible?

    Read the article

  • Are mobo raid controllers based on Intel ICH10R southbridge still considered software Raid?

    - by Breadtruck
    So do you still need specific software/drivers (intel matrix?) installed to manage the raid controller, setup the array. If the raid chipset is on-board the motherboard and it uses the CPU, and say I am using a Core 2 Quad Q9550, would a hardware based card still out perform the motherboard chipset? This is for a home workstation and I could spend $300 on a areca ARC-1210 PCI-Express x8 SATA II but I want to be able to justify the money for the raid card. My motherboard is a GIGABYTE GA-EP45-UD3P UPDATE: I was going to RAID5 using 4 500 GB drives, and I was going to buy a controller card but this article got me thinking hmmm....Toms-Southbridge Battle

    Read the article

  • Can SATA be used to connect computers?

    - by André
    Can SATA be used to connect two computers together, just like a crossover Ethernet cable would do ? I know SATA has no "networking" features and even though a controller may have multiple ports, the drives don't "see" each other, and that in SATA one device acts as the host (the computer) and the other device is some kind of "client" (the storage drive). But still, did anyone attempt to make a kernel module that would make one computer appear as a "client" (so that the host's SATA controller detects it as a standard hard drive) and then set up like a pseudo-Ethernet link or a very high speed serial link (and then run pppd on it and do networking) ? Note : I know this is an unprofessional and totally stupid idea, I'm just asking out of curiosity.

    Read the article

  • Stop RAID 5 from Initializing

    - by Antz
    Hi, I am trying to follow Ictinike's guide on Recovering Intel RAID "Non-Member Disk" Error found here, Ictinike's RAID recovery Guide I have recreated my RAID array as per the instructions. However my RAID array status is then automatically set to: INITIALIZE When I boot back into my Windows XP desktop, the Intel Matrix Storage Utility begins to "Initialize" my drives. This is a long slow process that will take about 20 hours. I suspect all my data will be lost. I have gone back into my bios and disabled my RAID controller to prevent any further initialization and data loss. I have read that initialization will cause data loss. I've also read somewhere that it won't. I am not so confident in the latter. Is there anyway to stop this initialization process so I can continue to follow the steps in the recovery guide? Some system specs: ABIT IP35 Pro Motherboard ICH9R on board RAID controller

    Read the article

  • Server error 500: Undefinable problem with my Zend Framework based site

    - by sanders
    Hello everyone, Lately I had to reinstall my development site on my ubuntu machine since my system crashed after an os update. 4 days later my site is still not running as it should. Whenever i do an action which has in it an action on a database, it stops working. For example when Registring a new user, i get the following error: [Sun Jul 25 20:07:20 2010] [error] [client 127.0.0.1] PHP Notice: Trying to get property of non-object in /var/www/nrka2/application/bootstrap/Bootstrap.php on line 169, referer: http://nrka2/user/register [Sun Jul 25 20:07:20 2010] [error] [client 127.0.0.1] PHP Stack trace:, referer: http://nrka2/user/register [Sun Jul 25 20:07:20 2010] [error] [client 127.0.0.1] PHP 1. {main}() /var/www/nrka2/public/index.php:0, referer: http://nrka2/user/register [Sun Jul 25 20:07:20 2010] [error] [client 127.0.0.1] PHP 2. require() /var/www/nrka2/public/index.php:2, referer: http://nrka2/user/register [Sun Jul 25 20:07:20 2010] [error] [client 127.0.0.1] PHP 3. Zend_Application->bootstrap() /var/www/nrka2/application/application.php:23, referer: http://nrka2/user/register [Sun Jul 25 20:07:20 2010] [error] [client 127.0.0.1] PHP 4. Zend_Application_Bootstrap_BootstrapAbstract->bootstrap() /var/www/Zend/ZendFramework-1.10.6/library/Zend/Application.php:355, referer: http://nrka2/user/register [Sun Jul 25 20:07:20 2010] [error] [client 127.0.0.1] PHP 5. Zend_Application_Bootstrap_BootstrapAbstract->_bootstrap() /var/www/Zend/ZendFramework-1.10.6/library/Zend/Application/Bootstrap/BootstrapAbstract.php:583, referer: http://nrka2/user/register [Sun Jul 25 20:07:20 2010] [error] [client 127.0.0.1] PHP 6. Zend_Application_Bootstrap_BootstrapAbstract->_executeResource() /var/www/Zend/ZendFramework-1.10.6/library/Zend/Application/Bootstrap/BootstrapAbstract.php:619, referer: http://nrka2/user/register [Sun Jul 25 20:07:20 2010] [error] [client 127.0.0.1] PHP 7. Bootstrap->_initViewSettings() /var/www/Zend/ZendFramework-1.10.6/library/Zend/Application/Bootstrap/BootstrapAbstract.php:666, referer: http://nrka2/user/register [Sun Jul 25 20:07:22 2010] [error] [client 127.0.0.1] PHP Notice: Trying to get property of non-object in /var/www/nrka2/application/bootstrap/Bootstrap.php on line 169, referer: http://nrka2/css/main.css [Sun Jul 25 20:07:22 2010] [error] [client 127.0.0.1] PHP Stack trace:, referer: http://nrka2/css/main.css [Sun Jul 25 20:07:22 2010] [error] [client 127.0.0.1] PHP 1. {main}() /var/www/nrka2/public/index.php:0, referer: http://nrka2/css/main.css [Sun Jul 25 20:07:22 2010] [error] [client 127.0.0.1] PHP 2. require() /var/www/nrka2/public/index.php:2, referer: http://nrka2/css/main.css [Sun Jul 25 20:07:22 2010] [error] [client 127.0.0.1] PHP 3. Zend_Application->bootstrap() /var/www/nrka2/application/application.php:23, referer: http://nrka2/css/main.css [Sun Jul 25 20:07:22 2010] [error] [client 127.0.0.1] PHP 4. Zend_Application_Bootstrap_BootstrapAbstract->bootstrap() /var/www/Zend/ZendFramework-1.10.6/library/Zend/Application.php:355, referer: http://nrka2/css/main.css [Sun Jul 25 20:07:22 2010] [error] [client 127.0.0.1] PHP 5. Zend_Application_Bootstrap_BootstrapAbstract->_bootstrap() /var/www/Zend/ZendFramework-1.10.6/library/Zend/Application/Bootstrap/BootstrapAbstract.php:583, referer: http://nrka2/css/main.css [Sun Jul 25 20:07:22 2010] [error] [client 127.0.0.1] PHP 6. Zend_Application_Bootstrap_BootstrapAbstract->_executeResource() /var/www/Zend/ZendFramework-1.10.6/library/Zend/Application/Bootstrap/BootstrapAbstract.php:619, referer: http://nrka2/css/main.css [Sun Jul 25 20:07:22 2010] [error] [client 127.0.0.1] PHP 7. Bootstrap->_initViewSettings() /var/www/Zend/ZendFramework-1.10.6/library/Zend/Application/Bootstrap/BootstrapAbstract.php:666, referer: http://nrka2/css/main.css My Bootstrap class looks like this: <?php class Bootstrap extends Zend_Application_Bootstrap_Bootstrap{ /** * * @var unknown_type */ public $frontcontroller; /** * * @var unknown_type */ protected $_logger; /** * * @var unknown_type */ protected $_acl; /** * * @var unknown_type */ protected $_auth; /** * Setup the logging */ protected function _initLogging() { $this->bootstrap('frontController'); $logger = new Zend_Log(); $writer = 'production' == $this->getEnvironment() ? new Zend_Log_Writer_Stream(APPLICATION_PATH . '/../data/logs/app.log') : new Zend_Log_Writer_Firebug(); $logger->addWriter($writer); if ('production' == $this->getEnvironment()) { $filter = new Zend_Log_Filter_Priority(Zend_Log::CRIT); $logger->addFilter($filter); } $this->_logger = $logger; Zend_Registry::set('log', $logger); } protected function _initDefaultModuleAutoloader(){ $this->_logger->info('Bootstrap '. __METHOD__); $this->_resourceLoader = new Zend_Application_Module_Autoloader(array( 'namespace' => 'EventManager', 'basePath' => APPLICATION_PATH . '/modules/eventManager', )); $this->_resourceLoader->addResourceTypes(array( 'modelResource' => array( 'path' => 'models/resources', 'namespace' => 'Resource', ), 'service' => array( 'path' => 'services', 'namespace' => 'Service' ), )); } // @todo develop this function protected function _initDbProfiler(){ $this->_logger->info('Bootstrap ' . __METHOD__); if ('production' !== $this->getEnvironment()) { $this->bootstrap('db'); $profiler = new Zend_Db_Profiler_Firebug('All DB Queries'); $profiler->setEnabled(true); $this->getPluginResource('db')->getDbAdapter()->setProfiler($profiler); } } /** * Add Controller Action Helpers */ protected function _initActionHelpers() { $this->_logger->info('Bootstrap ' . __METHOD__); Zend_Controller_Action_HelperBroker::addHelper(new SF_Controller_Helper_Acl()); Zend_Controller_Action_HelperBroker::addHelper(new SF_Controller_Helper_RedirectCommon()); Zend_Controller_Action_HelperBroker::addHelper(new SF_Controller_Helper_Service()); } /** * * @return unknown_type */ protected function _initRoutes(){ $this->_logger->info('Initialize Routes '. __METHOD__); $this->bootstrap('frontController'); $router = $this->frontController->getRouter(); $route = new Zend_Controller_Router_route( 'register', array( 'controller' => 'user', 'action' => 'register' ) ); $router->addRoute('register',$route); $route = new Zend_Controller_Router_route( 'login', array( 'controller' => 'user', 'action' => 'login' ) ); $router->addRoute('login',$route); $route = new Zend_Controller_Router_route( 'logout', array( 'controller' => 'user', 'action' => 'logout' ) ); $router->addRoute('logout',$route); } /** * * @return void */ protected function _initLocale(){ $this->_logger->info('Bootstrap '.__METHOD__); $locale = new Zend_Locale('nl_NL'); Zend_Registry::set('Zend_Locale', $locale); } protected function _initAcl(){ $this->_acl = new EventManager_Service_Acl(); } /** * * @return void */ protected function _initViewSettings(){ $this->_logger->info('Bootstrap '.__METHOD__); $this->bootstrap('view'); $this->bootstrap('Acl'); $this->_view = $this->getResource('view'); //set encoding and doctype $this->_view->setEncoding('UTF-8'); $this->_view->doctype('XHTML1_STRICT'); $this->_view->headMeta()->appendHttpEquiv('Content-Type', 'text/html; charset=UTF-8'); $this->_view->headMeta()->appendHttpEquiv('Content-Language', 'en-US'); //@todo op een later moment moeten hier nog de stylesheets worden toegevoegd $this->_view->headLink()->appendStylesheet('/css/main.css'); //$this->_view->headTitle('Event Manager'); /* Set the head style. $this->_view->headTitle->headStyle(); */ $this->_view->headTitle()->setSeparator(' - '); $this->_auth = Zend_Auth::getInstance(); $navigation = new Zend_Config_Xml(APPLICATION_PATH.'/configs/navigation.xml','nav'); $navContainer = new Zend_Navigation($navigation); $this->_view->navigation($navContainer)->setAcl($this->_acl)->setRole($this->_auth->getStorage()->read()->usr_role); //THIS IS LINE 169!!!!!!!!! } /** * Add graceful error handling to the dispatch, this will handle * errors during Front Controller dispatch. */ public function run() { $errorHandling = $this->getOption('errorhandling'); try { parent::run(); } catch(Exception $e) { if (true == (bool) $errorHandling['graceful']) { $this->__handleErrors($e, $errorHandling['email']); } else { throw $e; } } } /** * Handle errors gracefully, this will work as long as the views, * and the Zend classes are available * * @param Exception $e * @param string $email */ protected function __handleErrors(Exception $e, $email) { header('HTTP/1.1 500 Internal Server Error'); $view = new Zend_View(); $view->addScriptPath(dirname(__FILE__) . '/../views/scripts'); echo $view->render('fatalError.phtml'); if ('' != $email) { $mail = new Zend_Mail(); $mail->setSubject('Fatal error in application Storefront'); $mail->addTo($email); $mail->setBodyText( $e->getFile() . "\n" . $e->getMessage() . "\n" . $e->getTraceAsString() . "\n" ); @$mail->send(); } } } I have tried to debug my code, but everyting goes well until I do somethign with the db. But I don't know what goes wrong with the db. I don't get any clear error messages. Can someone help me? Some more possible interesting data: [bootstrap] resources.db.adapter = "PDO_MYSQL" resources.db.isdefaulttableadapter = true resources.db.params.dbname = "ladosa" resources.db.params.username = "root" resources.db.params.password = "root" resources.db.params.hostname = "localhost" resources.db.params.charset = "UTF8" resources.db.params.profiler.enabled = true resources.db.params.profiler.class = Zend_Db_Profiler_Firebug Autoloadernamespaces[] = "Zend_" Autoloadernamespaces[] = "SF_" phpsettings.display_errors = 0 phpsettings.error_reporting = 8191 phpSettings.date.timezone = "Europe/Amsterdam" bootstrap.path = APPLICATION_PATH"/bootstrap/Bootstrap.php" pluginPaths.resource_ = APPLICATION_PATH"/resources" resources.frontcontroller.moduledirectory = APPLICATION_PATH"/modules" resources.frontcontroller.defaultmodule = "eventManager" resources.frontcontroller.params.prefixDefaultModule = true resources.frontcontroller.exceptions = false resources.view[] = "" resources.layout.layoutPath = APPLICATION_PATH "/layouts/scripts" resources.view.encoding = "UTF-8" resources.view.title = Rode kruis Vrijwilligers applicatie ;resources.view.helperPath.Default_View_Helper = APPLICATION_PATH "/modules/eventManager/views/helpers" resources.layout.layout = "main" [production:bootstrap] [development:bootstrap] ;resources.frontController.throwExceptions = 1 ;phpSettings.display_startup_errors=1 ;phpSettings.display_errors = 1 ;resources.frontcontroller.throwerrors = [test:production] btw. I CAN login to my database command line with the given username and password. Update: today i decided to investigate on my http request and i came to an error 500. My apache logs don't give any related information, I think. I posted the logs above. Any idea's?

    Read the article

  • Simultaneous read/write to RAID array slows server to a crawl

    - by Jeff Leyser
    Fairly beefy NFS/SMB server (32GB RAM, 2 Xeon quad cores) with LSI MegaRAID 8888ELP controlling 12 drives configured into 3 different arrays. 5 2TB drives are grouped into a RAID 6 array. As expected, write performance to the array is slow. However, sustained, simultaneous read/write to the array (wether through NFS or done locally) seems to practically block any other access to anything else on the controller. For example, if I do: cp /home/joe/BigFile /home/joe/BigFileCopy where BigFile is 20G, then even a simple ls /home/jane will take many 10s of seconds to complete. In addition, an ls /backup will also take many tens of seconds, even though /backup is a different array on the same controller. As soon as the cp is done, everything is back to normal. cp /home/joe/BigFile /backup/BigFile does not exhibit this behavior. It's only when doing read/write to the same array.

    Read the article

  • Windows Disk I/O Analysis

    - by Jonathon
    It appears that we are having a problem with the disk i/o speed on our Windows 2003 Enterprise Edition server (64-bit). As we were initializing a database that created two 1G tablespaces on 3 different machines, it became obvious that the two smaller machines (each 32-bit Windows 2003 Standard Edition with less RAM) killed the larger machine when creating the files. The larger machine took 10x as long to create the tablespaces than did the other machines. Now, I am left wondering how that could be. What programs or scripts would you guys recommend for tracking down the I/O problem? I think the issue may be with the controller card (all boxes are hardware RAID 10, but have different controller cards), but I would like to check the actual disk I/O speed as well, so I have some hard numbers to work with. Any help would be appreciated.

    Read the article

  • Can't access USB drive anymore

    - by marie
    I have a 32 GB Lacie Cookey USB flash disk that doesn't show in the Computer window but it's visible as a device. cmd > diskpart DISKPART> list disk Disk ### Status Size -------- ------------- ------ Disk 0 Online 149 G Disk 1 No Media 0 DISKPART> select disk 1 Disk 1 is now the selected disk. DISKPART> clean Virtual Disk Service error: There is no media in the device. It also appears in the Disk Management tool, but the box is empty. Is there anything I can do or is it dead? ............................................................ output from ChipGenius: Description: [F:]USB Mass Storage Device(LaCie CooKey) Device Type: Mass Storage Device Protocal Version: USB 2.00 Current Speed: High Speed Max Current: 200mA USB Device ID: VID = 059F PID = 103B Serial Number: 070535924B170C18 Device Vendor: LaCie Device Name: CooKey Device Revision: 0100 Manufacturer: LaCie Product Model: CooKey Product Revision: PMAP Controller Vendor: Phison Controller Part-Number: PS2251-67(PS2267) - F/W 06.08.53 [2012-09-26] Flash ID code: 983AA892 - Toshiba [TLC] Tools on web: http://dl.mydigit.net/special/up/phison.html