Search Results

Search found 18279 results on 732 pages for 'component services'.

Page 14/732 | < Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >

  • Creating, using and managing XML component dictionaries quick tutorials

    - by drrwebber
    XML Component Dictionary capabilities are provided in conjunction with the CAM Editor toolset.  These dictionaries accelerate the development of consistent XML information exchanges using standard sets of dictionary components. The quick tutorials are aimed at showing the 'how to' of the basic capabilities to jump start use of XML dictionaries with the CAM Editor. The collection of dictionary tutorials videos run for a total of approximately 20 minutes.  Each video can be reviewed individually also. Learn how to use the dictionary functions to create dictionaries by harvesting data model components from existing XSD schema, SQL database table schema, or simple Excel / Open Office spreadsheets with tables of components listed.Also included are tips and functions relating to use of NIEM exchange development, IEPD and EIEM techniques.These videos should be viewed in conjunction with reviewing the overall concepts and techniques described in the companion video on the CAM Editor and Dictionaries overview.  The approach is aligned with OASIS and Core Components Technical Specification (CCTS) standards specifications for XML components and dictionaries.Dictionary collections can be stored locally on the file system, or local network, or collaboratively on the web or cloud deployment, or can be shared and managed securely using the Oracle Enterprise Repository (OER) tool. Also included are techniques relating to the use of the NIEM approach for developing XML exchange schema and IEPD packages.  This includes generating reuse scores, wantlist, and cross reference spreadsheets. Included in the latest release of the CAM Editor is the ability to use the analyse dictionary tool to determine duplicate components, conflicting component definitions, missing component descriptions and so on.  This ensures high quality dictionary component specifications.  Using the CAM Editor you can also create MindMap models and UML physical models of your dictionary components sets. For a complete guide to using the CAM Editor see the main YouTube video tutorials website and the CAM Editor website.

    Read the article

  • Why is my ServiceOperation method missing from my WCF Data Services client proxy code?

    - by Kev
    I have a simple WCF Data Services service and I want to expose a Service Operation as follows: [System.ServiceModel.ServiceBehavior(IncludeExceptionDetailInFaults = true)] public class ConfigurationData : DataService<ProductRepository> { // This method is called only once to initialize service-wide policies. public static void InitializeService(IDataServiceConfiguration config) { config.SetEntitySetAccessRule("*", EntitySetRights.ReadMultiple | EntitySetRights.ReadSingle); config.SetServiceOperationAccessRule("*", ServiceOperationRights.All); config.UseVerboseErrors = true; } // This operation isn't getting generated client side [WebGet] public IQueryable<Product> GetProducts() { // Simple example for testing return (new ProductRepository()).Product; } Why isn't the GetProducts method visible when I add the service reference on the client?

    Read the article

  • Cannot Change "Log on through Terminal Services" in Local Security Policy XP from Server 2008 GP

    - by Campo
    This is a mixed AD environment, Server 2003 R2 and 2008 R2 I have a 2003 AD R2 and a 2008 R2 AD. GPO is usually managed from the 2008 R2 machine. I have a RD Gateway on another server as well. I setup the CAP and RAP to allow a normal user to log on to the departments workstation. I also adjusted the GPO for that OU to allow Log on trhough Remote Desktop Gateway for the user group. This worked on my windows 7 workstation. But unfortunately the policy is a different name in XP "allow log on through Terminal Services" I can get through right into the machine but when the log on actually happens to the local machine i get the "Cannot log on interactively" error. This is set in (for the local machine) Secpol.msc Local Security Policy "user rights assignment" but is controlled by the GPO in Computer Configuration Policies Security Settings Local Policies "User Rights Assignment" Do I simply need to adjust the same setting on the same GPO but with a server 2003 GP editor? Feel like that could cause issues... Looking for some direction. Or if anyone has run into this issue yet. UPDATE Should this work? support.microsoft.com/kb/186529 Still seems like I will have the issue as the actual GP settings for Log on through Terminal Services is still different between Server 2008 R2 and 2003 R2.... Another Thought: Should I delete the GPO made for the department and remake it with the 2003 R2 server? I have no 2008 specific settings as the whole department runs XP other than myself. If that's a solution I will move my computer out of the department as a solution... Thoughts?

    Read the article

  • HP Officejet 4500 G510n-z Not Showing up in Remote Desktop (Terminal Services)

    - by Greg_the_Ant
    I installed this printer on a windows XP machine. First using the wireless option, and later using USB. In both cases when I connect to my other computer (also Windows XP) via terminal services and check printers in the local resources tab it does not show up on the remote session. I used to have a Samsung connected to my local computer over USB and and that worked fine over terminal services. Things I tried so far: I did read this page and installed the software fix on both computers: (Printers that use ports that do not begin with...) I installed the minimum HP software install on the remote computer and that didn't help either. I also tried running the add new printer wizard on the remote computer: I selected "local printer attached to this computer" and did not check the "automatically.." option. On the next page of the wizard I can select an option for "use the following port". I see options for TS001 through TS009 there. I'm assuming those are coming from the local machine. I tried clicking each one and then checking "have disk" and pointing it to C:\3be8dc611b11322e8ddf8a67\i386\msxpsdrv.inf 1 but for every single TS00.. port it says "The specified location does not contain information about your hardware." Any help would be greatly appreciated. I'm pretty stuck at this point. 1 C:\3be8dc611b11322e8ddf8a67 is the folder I extracted the HP driver software to after I downloaded it.

    Read the article

  • Explorer.exe not starting after login on Windows Server 2003 (Terminal Services and console)

    - by Pepperoni Icecream
    When users login to a Windows Server 2003 R2 running Terminal Services they have a blank desktop. Upon inspection, explorer.exe is not running. When I login as administrator, using either RDP or to the console, I am having the same issue. I can pull up the taskman and start explorer.exe manually. I have another Terminal Server setup exactly the same way (same apps, settings, GPO, etc . . .) the only difference is we deployed Symantec Endpoint Client 11.0.5 on Friday. For some reason the working Terminal Server is still on 11.0.4, but the suspect server received the 11.0.5 client upgrade. I checked the eventviewer for any relevant explorer.exe entries to no avail. It seems that if SEP is preventing explorer.exe from starting at login it would do the same for the domain admin starting explorer.exe from the taskman. I disabled the SEP client and services on the server and issued smc -stop and tried logging in again. Still no explorer.exe. So I'm not sure if the client upgrade is relevant but it is worth mentioning since that was the last system change. The 2 servers are members of a NLB group. I took the bad terminal server out of the group until the issue is resolved. Actually stopped the host using NLB manager Any help is appreciated.

    Read the article

  • SharePoint Business Connectivity Services (BCS) Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'

    - by g18c
    I am running SharePoint 2010 with SQL 2012, I am trying to get Business Connectivity Services (BCS) running but I am facing a double-hope authentication issue. Everytime I try to connect to the external BCS list created in SharePoint designer, I get the error Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. In the event viewer on the SQL server I see a login failure for an anonymous user from the SP server IP address. Background information below: I have enabled Kerberos under SharePoint Central admin. I have the following AD domain accounts: SP_Farm - main website pool SP_Services - for SharePoint services (including BCS) SQL_Engine - SQL database engine I then created the following with SetSPN: SetSPN -S http/intranet mydomain\SP_Farm SetSPN -S http/intranet.mydomain.local mydomain\SP_Farm SetSPN -S SPSvc/SPS mydomain\SP_Farm SetSPN -S MSSQLSvc/SQL1 mydomain\SQL_DatabaseEngine SetSPN -S MSSQLSvc/SQL1.mydomain.local mydomain\SQL_DatabaseEngine SetSPN -S MSSQLSvc/SQL1:1433 mydomain\SQL_DatabaseEngine SetSPN -S MSSQLSvc/SQL1.mydomain.local:1433 mydomain\SQL_DatabaseEngine I then delegated the AD accounts for any authentication protocol to the following: SP_Farm - SP_Farm (http service type, intranet) SP_Farm - SQL_DatabaseEngine (MSSQLSvc, sql1) SP_Service - SP_Service (SPSvc) SP_Service - SQL_DatabaseEngine (MSSQLSvc, sql1) I have also checked the WFE is being logged on to with Kerberos, with the WFE server event log showing event ID 4624 with Kerberos authentication, this is OK. The SQL is also showing connections authenticated as Kerberos from the WFE with the following query: Select s.session_id, s.login_name, s.host_name, c.auth_scheme from sys.dm_exec_connections c inner join sys.dm_exec_sessions s on c.session_id = s.session_id Despite the above, credentials are not passed from the client through the SharePoint server to the SQL server, only the anonymous account is used. I get the following error in the WFE server for 'BusinessData' ID 8080: Could not open connection using 'data source=sql1.mydomain.local;initial catalog=MSCRM;integrated security=SSPI;pooling=true;persist security info=false' in App Domain '/LM/W3SVC/1848937658/ROOT-1-129922939694071446'. The full exception text is: Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. If I set a username and password with the Secure Store Service and set the external list to use the impersonated credentials, the list works. Any ideas what I have missed and what can be tried next?

    Read the article

  • One Active Directory, Multiple Remote Desktop Services (Server 2012 solution)

    - by Trinitrotoluene
    What I am trying to do is quite complex, so I figured I'd throw it out to a wider audience to see if anyone can find a flaw. What I am trying to do (as an MSP/VAR) is design a solution that will give multiple companies a session based remote desktop (companies that need to be kept completely seperate), using only a handful of servers. This is how I imagine it at the moment: CORE SERVER - Server 2012 Datacentre (All below are HyperV servers) Server1: Cloud-DC01 (Active Directory Domain Services for mycloud.local) Server2: Cloud-EX01 (Exchange Server 2010 running multi tenant mode) Server3: Cloud-SG01 (Remote Desktop Gateway) CORE SERVER 2 - Server 2012 Datacentre (All below are HyperV servers) Server1: Cloud-DC02 (Active Directory Domain Services for mycloud.local) Server2: Cloud-TS01 (Remote Desktop Session Host for Company A) Server3: Cloud-TS02 (Remote Desktop Session Host for Company B) Server4: Cloud-TS03 (Remote Desktop Session Host for Company C) What I thought about doing was setting up each Organisation in their own OU (perhaps creating their OU structure based on the Excahnge 2010 tenant OU structure so the accounts are linked). Each company would get a Remote Desktop Session Host server that would also serve as a file server. This server would be seperated from the rest on its own range. The server Cloud-SG01 would have access to all these networks and route the traffic to the appropriate network when a client connects and authenticated so they are pushed onto the correct server (Based on session collections in 2012). I won't lie this is something I have come up with quite quickly so there may well be something gapingly obvious that I am missing. Any feedback would be appreciated.

    Read the article

  • 100% CPU use when new usb device plugged in - services.exe / Windows Server 2003

    - by Will3265
    On my server I am trying to install a new usb drive but all that happens is that the system starts using huge amounts of processor cycles with services.exe. On closer inspection with process explorer there is a thread called umpnpmgr.dll using most of the services.exe processor time. I left it for a half hour and still nothing happened. Rebooted and tried again, same result. Tried a different usb drive, then a flash drive but still same issue. Tried updating driver but it said the update function was already in action. I have used process explorer to kill the thread now so the server can still perform its intended functions. Any device that was previously installed before this began happening will still work but any device new to the system will not. My question(s) is/are: Is there a way to manually install the device into the registry so Windows thinks it is a previously installed device? Or can this problem be repaired through anything other than a reinstall? To do a reinstall would mean backing up large amounts of data which is hard with a usb drive and insufficient space on all other network machines. Any help would be greatly appreciated. William

    Read the article

  • SSIS Lookup component tuning tips

    - by jamiet
    Yesterday evening I attended a London meeting of the UK SQL Server User Group at Microsoft’s offices in London Victoria. As usual it was both a fun and informative evening and in particular there seemed to be a few questions arising about tuning the SSIS Lookup component; I rattled off some comments and figured it would be prudent to drop some of them into a dedicated blog post, hence the one you are reading right now. Scene setting A popular pattern in SSIS is to use a Lookup component to determine whether a record in the pipeline already exists in the intended destination table or not and I cover this pattern in my 2006 blog post Checking if a row exists and if it does, has it changed? (note to self: must rewrite that blog post for SSIS2008). Fundamentally the SSIS lookup component (when using FullCache option) sucks some data out of a database and holds it in memory so that it can be compared to data in the pipeline. One of the big benefits of using SSIS dataflows is that they process data one buffer at a time; that means that not all of the data from your source exists in the dataflow at the same time and is why a SSIS dataflow can process data volumes that far exceed the available memory. However, that only applies to data in the pipeline; for reasons that are hopefully obvious ALL of the data in the lookup set must exist in the memory cache for the duration of the dataflow’s execution which means that any memory used by the lookup cache will not be available to be used as a pipeline buffer. Moreover, there’s an obvious correlation between the amount of data in the lookup cache and the time it takes to charge that cache; the more data you have then the longer it will take to charge and the longer you have to wait until the dataflow actually starts to do anything. For these reasons your goal is simple: ensure that the lookup cache contains as little data as possible. General tips Here is a simple tick list you can follow in order to tune your lookups: Use a SQL statement to charge your cache, don’t just pick a table from the dropdown list made available to you. (Read why in SELECT *... or select from a dropdown in an OLE DB Source component?) Only pick the columns that you need, ignore everything else Make the database columns that your cache is populated from as narrow as possible. If a column is defined as VARCHAR(20) then SSIS will allocate 20 bytes for every value in that column – that is a big waste if the actual values are significantly less than 20 characters in length. Do you need DT_WSTR typed columns or will DT_STR suffice? DT_WSTR uses twice the amount of space to hold values that can be stored using a DT_STR so if you can use DT_STR, consider doing so. Same principle goes for the numerical datatypes DT_I2/DT_I4/DT_I8. Only populate the cache with data that you KNOW you will need. In other words, think about your WHERE clause! Thinking outside the box It is tempting to build a large monolithic dataflow that does many things, one of which is a Lookup. Often though you can make better use of your available resources by, well, mixing things up a little and here are a few ideas to get your creative juices flowing: There is no rule that says everything has to happen in a single dataflow. If you have some particularly resource intensive lookups then consider putting that lookup into a dataflow all of its own and using raw files to pass the pipeline data in and out of that dataflow. Know your data. If you think, for example, that the majority of your incoming rows will match with only a small subset of your lookup data then consider chaining multiple lookup components together; the first would use a FullCache containing that data subset and the remaining data that doesn’t find a match could be passed to a second lookup that perhaps uses a NoCache lookup thus negating the need to pull all of that least-used lookup data into memory. Do you need to process all of your incoming data all at once? If you can process different partitions of your data separately then you can partition your lookup cache as well. For example, if you are using a lookup to convert a location into a [LocationId] then why not process your data one region at a time? This will mean your lookup cache only has to contain data for the location that you are currently processing and with the ability of the Lookup in SSIS2008 and beyond to charge the cache using a dynamically built SQL statement you’ll be able to achieve it using the same dataflow and simply loop over it using a ForEach loop. Taking the previous data partitioning idea further … a dataflow can contain more than one data path so why not split your data using a conditional split component and, again, charge your lookup caches with only the data that they need for that partition. Lookups have two uses: to (1) find a matching row from the lookup set and (2) put attributes from that matching row into the pipeline. Ask yourself, do you need to do these two things at the same time? After all once you have the key column(s) from your lookup set then you can use that key to get the rest of attributes further downstream, perhaps even in another dataflow. Are you using the same lookup data set multiple times? If so, consider the file caching option in SSIS 2008 and beyond. Above all, experiment and be creative with different combinations. You may be surprised at what works. Final  thoughts If you want to know more about how the Lookup component differs in SSIS2008 from SSIS2005 then I have a dedicated blog post about that at Lookup component gets a makeover. I am on a mini-crusade at the moment to get a BULK MERGE feature into the database engine, the thinking being that if the database engine can quickly merge massive amounts of data in a similar manner to how it can insert massive amounts using BULK INSERT then that’s a lot of work that wouldn’t have to be done in the SSIS pipeline. If you think that is a good idea then go and vote for BULK MERGE on Connect. If you have any other tips to share then please stick them in the comments. Hope this helps! @Jamiet Share this post: email it! | bookmark it! | digg it! | reddit! | kick it! | live it!

    Read the article

  • How-to tell the ViewCriteria a user chose in an af:query component

    - by frank.nimphius
    Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} The af:query component defines a search form for application users to enter search conditions for a selected View Criteria. A View Criteria is a named where clauses that you can create declaratively on the ADF Business Component View Object. A default View Criteria that allows users to search in all attributes exists by default and exposed in the Data Controls panel. To create an ADF Faces search form, expand the View Object node that contains the View Criteria definition in the Data Controls panel. Drag the View Criteria that should be displayed as the default criteria onto the page and choose Query in the opened context menu. One of the options within the Query option is to create an ADF Query Panel with Table, which displays the result set in a table view, which can have additional column filters defined. Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} To intercept the user query for modification, or just to know about the selected View Criteria, you override the QueryListener property on the af:query component of the af:table component. Overriding the QueryListener on the table makes sense if the table allows users to further filter the result set using column filters.To override the default QueryListener, copy the existing string referencing the binding layer to the clipboard and then select Edit from the field context menu (press the arrow icon to open it) to selecte or create a new managed bean and method to handle the query event.  The code below is from a managed bean with custom query listener handlers defined for the af:query component and the af:table component. The default listener entry copied to the clipboard was "#{bindings.ImplicitViewCriteriaQuery.processQuery}"  public void onQueryList(QueryEvent queryEvent) {   // The generated QueryListener replaced by this method   //#{bindings.ImplicitViewCriteriaQuery.processQuery}        QueryDescriptor qdes = queryEvent.getDescriptor();          //print or log selected View Criteria   System.out.println("NAME "+qdes.getName());           //call default Query Event        invokeQueryEventMethodExpression("      #{bindings.ImplicitViewCriteriaQuery.processQuery}",queryEvent);  } public void onQueryTable(QueryEvent queryEvent) {   // The generated QueryListener replaced by this method   //#{bindings.ImplicitViewCriteriaQuery.processQuery}   QueryDescriptor qdes = queryEvent.getDescriptor();   //print or log selected View Criteria   System.out.println("NAME "+qdes.getName());                   invokeQueryEventMethodExpression(     "#{bindings.ImplicitViewCriteriaQuery.processQuery}",queryEvent); } private void invokeQueryEventMethodExpression(                        String expression, QueryEvent queryEvent){   FacesContext fctx = FacesContext.getCurrentInstance();   ELContext elctx = fctx.getELContext();   ExpressionFactory efactory   fctx.getApplication().getExpressionFactory();     MethodExpression me =     efactory.createMethodExpression(elctx,expression,                                     Object.class,                                     new Class[]{QueryEvent.class});     me.invoke(elctx, new Object[]{queryEvent}); } Of course, this code also can be used as a starting point for other query manipulations and also works with saved custom criterias. To read more about the af:query component, see: http://download.oracle.com/docs/cd/E15523_01/apirefs.1111/e12419/tagdoc/af_query.html

    Read the article

  • SQL SERVER – SSIS Look Up Component – Cache Mode – Notes from the Field #028

    - by Pinal Dave
    [Notes from Pinal]: Lots of people think that SSIS is all about arranging various operations together in one logical flow. Well, the understanding is absolutely correct, but the implementation of the same is not as easy as it seems. Similarly most of the people think lookup component is just component which does look up for additional information and does not pay much attention to it. Due to the same reason they do not pay attention to the same and eventually get very bad performance. Linchpin People are database coaches and wellness experts for a data driven world. In this 28th episode of the Notes from the Fields series database expert Tim Mitchell (partner at Linchpin People) shares very interesting conversation related to how to write a good lookup component with Cache Mode. In SQL Server Integration Services, the lookup component is one of the most frequently used tools for data validation and completion.  The lookup component is provided as a means to virtually join one set of data to another to validate and/or retrieve missing values.  Properly configured, it is reliable and reasonably fast. Among the many settings available on the lookup component, one of the most critical is the cache mode.  This selection will determine whether and how the distinct lookup values are cached during package execution.  It is critical to know how cache modes affect the result of the lookup and the performance of the package, as choosing the wrong setting can lead to poorly performing packages, and in some cases, incorrect results. Full Cache The full cache mode setting is the default cache mode selection in the SSIS lookup transformation.  Like the name implies, full cache mode will cause the lookup transformation to retrieve and store in SSIS cache the entire set of data from the specified lookup location.  As a result, the data flow in which the lookup transformation resides will not start processing any data buffers until all of the rows from the lookup query have been cached in SSIS. The most commonly used cache mode is the full cache setting, and for good reason.  The full cache setting has the most practical applications, and should be considered the go-to cache setting when dealing with an untested set of data. With a moderately sized set of reference data, a lookup transformation using full cache mode usually performs well.  Full cache mode does not require multiple round trips to the database, since the entire reference result set is cached prior to data flow execution. There are a few potential gotchas to be aware of when using full cache mode.  First, you can see some performance issues – memory pressure in particular – when using full cache mode against large sets of reference data.  If the table you use for the lookup is very large (either deep or wide, or perhaps both), there’s going to be a performance cost associated with retrieving and caching all of that data.  Also, keep in mind that when doing a lookup on character data, full cache mode will always do a case-sensitive (and in some cases, space-sensitive) string comparison even if your database is set to a case-insensitive collation.  This is because the in-memory lookup uses a .NET string comparison (which is case- and space-sensitive) as opposed to a database string comparison (which may be case sensitive, depending on collation).  There’s a relatively easy workaround in which you can use the UPPER() or LOWER() function in the pipeline data and the reference data to ensure that case differences do not impact the success of your lookup operation.  Again, neither of these present a reason to avoid full cache mode, but should be used to determine whether full cache mode should be used in a given situation. Full cache mode is ideally useful when one or all of the following conditions exist: The size of the reference data set is small to moderately sized The size of the pipeline data set (the data you are comparing to the lookup table) is large, is unknown at design time, or is unpredictable Each distinct key value(s) in the pipeline data set is expected to be found multiple times in that set of data Partial Cache When using the partial cache setting, lookup values will still be cached, but only as each distinct value is encountered in the data flow.  Initially, each distinct value will be retrieved individually from the specified source, and then cached.  To be clear, this is a row-by-row lookup for each distinct key value(s). This is a less frequently used cache setting because it addresses a narrower set of scenarios.  Because each distinct key value(s) combination requires a relational round trip to the lookup source, performance can be an issue, especially with a large pipeline data set to be compared to the lookup data set.  If you have, for example, a million records from your pipeline data source, you have the potential for doing a million lookup queries against your lookup data source (depending on the number of distinct values in the key column(s)).  Therefore, one has to be keenly aware of the expected row count and value distribution of the pipeline data to safely use partial cache mode. Using partial cache mode is ideally suited for the conditions below: The size of the data in the pipeline (more specifically, the number of distinct key column) is relatively small The size of the lookup data is too large to effectively store in cache The lookup source is well indexed to allow for fast retrieval of row-by-row values No Cache As you might guess, selecting no cache mode will not add any values to the lookup cache in SSIS.  As a result, every single row in the pipeline data set will require a query against the lookup source.  Since no data is cached, it is possible to save a small amount of overhead in SSIS memory in cases where key values are not reused.  In the real world, I don’t see a lot of use of the no cache setting, but I can imagine some edge cases where it might be useful. As such, it’s critical to know your data before choosing this option.  Obviously, performance will be an issue with anything other than small sets of data, as the no cache setting requires row-by-row processing of all of the data in the pipeline. I would recommend considering the no cache mode only when all of the below conditions are true: The reference data set is too large to reasonably be loaded into SSIS memory The pipeline data set is small and is not expected to grow There are expected to be very few or no duplicates of the key values(s) in the pipeline data set (i.e., there would be no benefit from caching these values) Conclusion The cache mode, an often-overlooked setting on the SSIS lookup component, represents an important design decision in your SSIS data flow.  Choosing the right lookup cache mode directly impacts the fidelity of your results and the performance of package execution.  Know how this selection impacts your ETL loads, and you’ll end up with more reliable, faster packages. If you want me to take a look at your server and its settings, or if your server is facing any issue we can Fix Your SQL Server. Reference: Pinal Dave (http://blog.sqlauthority.com)Filed under: Notes from the Field, PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL Tagged: SSIS

    Read the article

  • Loose component cables causing HDMI video problems

    - by jwir3
    I'm not sure this is the correct forum, but I'll ask anyway. I have an A/V setup at home that has something like the following: Five Components (actually a few more, like a CD player, but they don't really relate to this question): Older Pioneer Receiver Digital Set Top Box Sony BluRay Player Samsung Plasma TV Speakers The reason for the receiver is so that all the sound can go through the speakers, rather than some going to the TV speakers and some to the external speakers. They are connected as follows: Digital Set Top Box connects via component video to Samsung TV directly via Component 2 (audio goes to Older Pioneer Receiver). Sony BluRay player is connected via HDMI 1 to TV, but audio goes to the receiver. Now, the problem I'm having is that when I have the digital set top box connected, there are times when the Netflix or Hulu streams I watch through the Sony BluRay player (it's connected to a router for internet access) will lose video. What I mean by this is that the sound of the episode will keep playing, but the screen will go black. If I jiggle the component cables, it will often come back. If I disconnect the component cables, it will always come back. I've noticed that one of the connections (the red component cable) doesn't like to sit very well in the component socket in the back of the digital set top box. It seems like there is a bad connection here, but it doesn't seem like this should be affecting the HDMI input at all. What I've noticed, though, is that when I disconnect the digital set top box completely (i.e. remove the component cable from the back of the TV), the problem seems to resolve itself. I'm not talking about actually removing the cable physically, because I thought perhaps the cables were mashing against one another, and possibly jiggling each other loose. To correct this possible problem, I took the component cable completely out of the cable ties it was in in the back of my entertainment center, as well as pulled the digital set top box out from the entertainment center altogether. It's now connected directly to the TV, without any other cables touching it to cause some kind of weird interference or just physical pulling on the cable. Same problem. If, however, I disconnect the component cable and just leave it sitting behind the TV, then the problem goes away. So, my question is this - what could be causing this? Is it a case where it's an improperly shielded component cable that's causing interference with the HDMI input, or something that's wrong with the TV? It's an intermittent problem, so it's difficult to track down. The TV isn't that old, so it's probably still under warranty. I'm just wondering if there is something else I can do that might reduce this problem without having to haul a massive television set out of my house to get repaired/replaced.

    Read the article

  • Re-deploy Reports from SCOM 2007 R2 Management Packs

    - by Gabriel Guimarães
    I've migrated Reporting Services on a SCOM 2007 R2 install, and noticed that the reports have not being copied. I can create a new report, but the ones I've had because of the management packs are gone. I've tried re-applying the Management Packs however it doesn't re-deploy them and when I try to access for example: Monitoring - Microsoft Windows Print Server - Microsoft Windows Server 2000 and 2003 Print Services - State View - select any item and click Alerts on the right menu. I get the following error: Date: 12/24/2010 12:40:35 PM Application: System Center Operations Manager 2007 R2 Application Version: 6.1.7221.0 Severity: Error Message: Cannot initialize report. Microsoft.Reporting.WinForms.ReportServerException: The item '/Microsoft.SystemCenter.DataWarehouse.Report.Library/Microsoft.SystemCenter.DataWarehouse.Report.Alert' cannot be found. (rsItemNotFound) at Microsoft.Reporting.WinForms.ServerReport.GetExecutionInfo() at Microsoft.Reporting.WinForms.ServerReport.GetParameters() at Microsoft.EnterpriseManagement.Mom.Internal.UI.Reporting.Parameters.ReportParameterBlock.Initialize(ServerReport serverReport) at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.ReportForm.SetReportJob(Object sender, ConsoleJobEventArgs args) The report doesn't exist on the reporting services side. how do I re-deploy this reports? Thanks in advance.

    Read the article

  • Re-deploy Reports on SCOM Management Packs

    - by Gabriel Guimarães
    I've migrated Reporting Services on a SCOM 2007 R2 install, and noticed that the reports have not being copied. I can create a new report, but the ones I've had because of the management packs are gone. I've tried re-applying the Management Packs however it doesn't re-deploy them and when I try to access for example: Monitoring - Microsoft Windows Print Server - Microsoft Windows Server 2000 and 2003 Print Services - State View - select any item and click Alerts on the right menu. I get the following error: Date: 12/24/2010 12:40:35 PM Application: System Center Operations Manager 2007 R2 Application Version: 6.1.7221.0 Severity: Error Message: Cannot initialize report. Microsoft.Reporting.WinForms.ReportServerException: The item '/Microsoft.SystemCenter.DataWarehouse.Report.Library/Microsoft.SystemCenter.DataWarehouse.Report.Alert' cannot be found. (rsItemNotFound) at Microsoft.Reporting.WinForms.ServerReport.GetExecutionInfo() at Microsoft.Reporting.WinForms.ServerReport.GetParameters() at Microsoft.EnterpriseManagement.Mom.Internal.UI.Reporting.Parameters.ReportParameterBlock.Initialize(ServerReport serverReport) at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.ReportForm.SetReportJob(Object sender, ConsoleJobEventArgs args) The report doesn't exist on the reporting services side. how do I re-deploy this reports? Thanks in advance.

    Read the article

  • Error configuring SQL Reporting Services 2005 on Windows 7

    - by Omu
    I've installed SQL Server 2005 with Reporting Services on Windows 7 Ultimate x64 and when I try to configure it when clicking on "Windows Service Identity" I get this error message: There was an error while switching panels. The most likely cause is an error retrieving WMI properties. The exception details are: InvalidArgument=Value of '1' is not valid for 'SelectedIndex'. Parameter name: SelectedIndex Here is a screenshot: EDIT: This problem disappeared after I installed SP3 for SQL Server. I have problems on the next panes though.

    Read the article

  • how do i lock down my preferences for Services .mmc snapin column layout and view type

    - by gerryLowry
    when "Services" opens, it's in Extended View. i prefer Standard view. i also prefer this column layout: Status | Startup Type | Log On As | Name | Description because when I expand all columns via Ctrl+(numeric keypad "+") what i need to see most i can view without being forced to scroll to the right. Problem: my preferred layout does not persist. QUESTION: how can i force Windows (2008 R2, 7, XP, et cetera) to remmember my settings? thnx / g.

    Read the article

  • Re-deploy only the reports on SCOM Management Packs

    - by Gabriel Guimarães
    I've migrated Reporting Services on a SCOM 2007 R2 install, and noticed that the reports have not being copied. I can create a new report, but the ones I've had because of the management packs are gone. I've tried re-applying the Management Packs however it doesn't re-deploy them and when I try to access for example: Monitoring - Microsoft Windows Print Server - Microsoft Windows Server 2000 and 2003 Print Services - State View - select any item and click Alerts on the right menu. I get the following error: Date: 12/24/2010 12:40:35 PM Application: System Center Operations Manager 2007 R2 Application Version: 6.1.7221.0 Severity: Error Message: Cannot initialize report. Microsoft.Reporting.WinForms.ReportServerException: The item '/Microsoft.SystemCenter.DataWarehouse.Report.Library/Microsoft.SystemCenter.DataWarehouse.Report.Alert' cannot be found. (rsItemNotFound) at Microsoft.Reporting.WinForms.ServerReport.GetExecutionInfo() at Microsoft.Reporting.WinForms.ServerReport.GetParameters() at Microsoft.EnterpriseManagement.Mom.Internal.UI.Reporting.Parameters.ReportParameterBlock.Initialize(ServerReport serverReport) at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.ReportForm.SetReportJob(Object sender, ConsoleJobEventArgs args) The report doesn't exist on the reporting services side. how do I re-deploy this reports? Thanks in advance.

    Read the article

  • Reporting Services print dialog pops up after drill through

    - by Craig
    Have encountered a problem with in Reporting Services 2005 with printing and drillthrough. If I view a report in Report Manager and then Print the report then I drillthrough from the first report to a second then when I click "back" to go back to the main report the Print dialog pops up. Has anyone else encountered this before? Does anyone know of any workarounds?

    Read the article

  • Terminal services and screen savers

    - by Corsair
    I have a Window Server 2008 R2 server acting as a terminal server for mobile devices running a single application, but I am having issues with the screen saver popping on after ten minutes. Is there a setting in terminal services to make the screensaver settings universal? If not, how should I approach this issue?

    Read the article

  • Why is a small fixed vocabulary seen as an advantage to RESTful services?

    - by Matt Esch
    So, a RESTful service has a fixed set of verbs in its vocabulary. A RESTful web service takes these from the HTTP methods. There are some supposed advantages to defining a fixed vocabulary, but I don't really grasp the point. Maybe someone can explain it. Why is a fixed vocabulary as outlined by REST better than dynamically defining a vocabulary for each state? For example, object oriented programming is a popular paradigm. RPC is described to define fixed interfaces, but I don't know why people assume that RPC is limited by these contraints. We could dynamically specify the interface just as a RESTful service dynamically describes its content structure. REST is supposed to be advantageous in that it can grow without extending the vocabulary. RESTful services grow dynamically by adding more resources. What's so wrong about extending a service by dynamically specifying a per-object vocabulary? Why don't we just use the methods that are defined on our objects as the vocabulary and have our services describe to the client what these methods are and whether or not they have side effects? Essentially I get the feeling that the description of a server side resource structure is equivalent to the definition of a vocabulary, but we are then forced to use the limited vocabulary in which to interact with these resources. Does a fixed vocabulary really decouple the concerns of the client from the concerns of the server? I surely have to be concerned with some configuration of the server, this is normally resource location in RESTful services. To complain at the use of a dynamic vocabulary seems unfair because we have to dynamically reason how to understand this configuration in some way anyway. A RESTful service describes the transitions you are able to make by identifying object structure through hypermedia. I just don't understand what makes a fixed vocabulary any better than any self-describing dynamic vocabulary, which could easily work very well in an RPC-like service. Is this just a poor reasoning for the limiting vocabulary of the HTTP protocol?

    Read the article

  • Trash Destination Adapter

    The Trash Destination and this article came from early experiences of using SSIS and community feedback at the time. When developing a package it is very useful to have a destination adapter that does nothing but consume rows with no setup requirement. You often want run a package part way through development, or just add a path so you can set a Data Viewer. There are stock tasks that can be used, but with the Trash Destination all columns are treated as selected automatically (usage type of read-only), so the pipeline knows they are required. It is also obvious that this is for development or diagnostic purposes, and is clearly not a part of the functional design of the package. It is also ideal for just playing around and exploring concepts in SSIS, and is often used in conjunction with the Data Generator Source. Using these two components it is easy to setup a test of an expression in the Derived Column Transformation for example. The Data Generator Source provides some dummy data, and the Trash Destination allows you to anchor the output path and set a Data Viewer to examine the results. It can also be used when performance tuning packages. It is a consistent and known quantity that has no external influences, so it is ideal as a destination when breaking the data flow into sections to isolate a bottleneck. The adapter is really simple to use and requires no setup. Simply drop it onto the pipeline designer and use it to terminate your data flow path. Installation The component is provided as an MSI file which you can download and run to install it. This simply places the files on disk in the correct locations and also installs the assemblies in the Global Assembly Cache as per Microsoft’s recommendations. You may need to restart the SQL Server Integration Services service, as this caches information about what components are installed, as well as restarting any open instances of Business Intelligence Development Studio (BIDS) / Visual Studio that you may be using to build your SSIS packages. Finally, for 2005/2008, you will have to add the transformation to the Visual Studio toolbox manually. Right-click the toolbox, and select Choose Items.... Select the SSIS Data Flow Items tab, and then check the Trash Destination transformation in the Choose Toolbox Items window. This process has been described in detail in the related FAQ entry for How do I install a task or transform component? We recommend you follow best practice and apply the current Microsoft SQL Server Service pack to your SQL Server servers and workstations. Downloads The Trash Destination is available for SQL Server 2005, SQL Server 2008 (includes R2) and SQL Server 2012. Please choose the version to match your SQL Server version, or you can install multiple versions and use them side by side if you have more than one version of SQL Server installed. Trash Destination for SQL Server 2005 Trash Destination for SQL Server 2008 Trash Destination for SQL Server 2012 Version History SQL Server 2012 Version 3.0.0.34 - SQL Server 2012 release. Includes upgrade support for both 2005 and 2008 packages to 2012. (5 Jun 2012) SQL Server 2008 Version 2.0.0.33 - SQL Server 2008 release. Includes support for upgrade of 2005 packages. RTM compatible, previously February 2008 CTP. (4 Mar 2008) Version 2.0.0.31 - SQL Server 2008 November 2007 CTP. (14 Feb 2008) SQL Server 2005 Version 1.0.2.18 - SQL Server 2005 RTM Refresh. SP1 Compatibility Testing. (12 Jun 2006) Version 1.0.1.1 - SQL Server 2005 IDW 15 June CTP. Minor enhancements over v1.0.1.0. (11 Jun 2005) Version 1.0.1.0 - SQL Server 2005 IDW 14 April CTP. First Public Release. (30 May 2005) Troubleshooting Make sure you have downloaded the version that matches your version of SQL Server. We offer separate downloads for SQL Server 2005, SQL Server 2008 and SQL Server 2012. If you an error when you try and use the component along the lines of The component could not be added to the Data Flow task. Please verify that this component is properly installed.  ... The data flow object "Konesans ..." is not installed correctly on this computer, this usually indicates that the internal cache of SSIS components needs to be updated. This is held by the SSIS service, so you need restart the the SQL Server Integration Services service. You can do this from the Services applet in Control Panel or Administrative Tools in Windows. You can also restart the computer if you prefer. You may also need to restart any current instances of Business Intelligence Development Studio (BIDS) / Visual Studio that you may be using to build your SSIS packages. The full error message is shown below for reference: TITLE: Microsoft Visual Studio ------------------------------ The component could not be added to the Data Flow task. Please verify that this component is properly installed. ------------------------------ ADDITIONAL INFORMATION: The data flow object "Konesans.Dts.Pipeline.TrashDestination.Trash, Konesans.Dts.Pipeline.TrashDestination, Version=1.0.1.0, Culture=neutral, PublicKeyToken=b8351fe7752642cc" is not installed correctly on this computer. (Microsoft.DataTransformationServices.Design) For 2005/2008, once installation is complete you need to manually add the task to the toolbox before you will see it and to be able add it to packages - How do I install a task or transform component? This is not necessary for SQL Server 2012 as the new SSIS toolbox automatically detects components. If you are still having issues then contact us, but please provide as much detail as possible about error, as well as which version of the the task you are using and details of the SSIS tools installed.

    Read the article

  • Role of systems in entity systems architecture

    - by bio595
    I've been reading a lot about entity components and systems and have thought that the idea of an entity just being an ID is quite interesting. However I don't know how this completely works with the components aspect or the systems aspect. A component is just a data object managed by some relevant system. A collision system uses some BoundsComponent together with a spatial data structure to determine if collisions have happened. All good so far, but what if multiple systems need access to the same component? Where should the data live? An input system could modify an entities BoundsComponent, but the physics system(s) need access to the same component as does some rendering system. Also, how are entities constructed? One of the advantages I've read so much about is flexibility in entity construction. Are systems intrinsically tied to a component? If I want to introduce some new component, do I also have to introduce a new system or modify an existing one? Another thing that I've read often is that the 'type' of an entity is inferred by what components it has. If my entity is just an id how can I know that my robot entity needs to be moved or rendered and thus modified by some system? Sorry for the long post (or at least it seems so from my phone screen)!

    Read the article

< Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >