Search Results

Search found 59139 results on 2366 pages for 'david butler(at)oracle com'.

Page 14/2366 | < Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >

  • WCF wrapper COM object

    - by LarryR
    I have a third party COM component (they don't offer a .Net assy), that has the additional feature that it only works under x86 compile. I am trying to wrap this in a WCF service, but if I select x86, the service won't start (System.BadImageFormatException). Any workarounds for this ? Thanks Larry

    Read the article

  • COM(C++) Programming Tutorials

    - by Deep-B
    Hey guys, I was wondering if there're any good sites that deal with learning C++/COM from the ground up? Looking for something like a crash course (two weeks, and not being hypothetical here). Assume knowledge in standard C/C++, or at least not a complete dummy.

    Read the article

  • Interviews Gone Bad.....Now What Do I Do?

    - by david.talamelli
    We have all done it at some stage of our working careers - you know those times when you leave an interview and then you think to yourself "why didn't I ask that question" or "I can't believe I said that" or "how could I have forgotten to say that". It happens to everyone but how you handle things moving forwards could be critical in helping you land that dream job. There is nothing better than seeing that dream job with the dream company that you are looking to work for advertised (or in some cases getting called by the Recruiter to let you know about that job). The role may seem perfect and it could be just what you are looking for and it is with the right company as well. You have sent in your resume and have subsequently had one, two or maybe three interviews for the role. After each step of the process you get a little bit more excited about the role as you start to think about your work day in your new role/company. Then it happens, you get it: you get The Phone Call to inform you that you have not been successful in securing the position that you have invested so much time and effort into. It can be disappointing to hear this news but what you do next is important in potentially keeping that door open for future opportunities with that company. How you handle yourself in this situation is important: if any of you remember the Choose Your Own Adventure Books do you: Tell the Recruiter (maybe get aggressive) they are wrong in their assessment and that you are the right candidate for the role Switch off and say ok thanks and hang up without engaging in any further dialogue Thank the company for their time and enquire if there may be any other opportunities in the future to explore If you chose the first option - the company in question may consider whether or not to look at you for other opportunities. How you handle yourself in the recruitment process could be an indication of how you would deal with clients/colleagues in your role and the impression that you leave a potential employer may be what sticks in their mind when they think of you (eg: isn't that the person who couldn't handle it when we told him he wasn't right for our role). The second option potentially produces a similar outcome. If you rush to get off the phone, the company may come back to you to talk about other roles when they come up, but you also leave open the potential thought with the company you were only interested in that role and therefore not interested in any other opportunities. Why take the risk of the company thinking that and potentially not getting back to you in the future. By picking the third option, you actively engage with the company and keep the dialogue open for future discussions. Ok, so you didn't get the role you interviewed for - you don't know who else the company may have been interviewing - maybe they found someone who was a better fit, or maybe there were too many boxes you didn't tick to step straight into that specific role. Take a deep breath and keep the company engaged. You are fresh in their mind - take advantage of that fact and let them know that while you respect their decision, that you are still interested in the company and would like to be kept in mind for future roles. Ask if it is ok to keep in touch and when they would like to keep in touch, as long as you are interested let them know you are still interested. You do need to balance that though if you come across as too keen or start stalking people - it could equally damage your brand. Companies normally have more than one open role. New roles are created all the time, circumstances change and hiring people is not a static business, it changes course from everyone's best laid initial plans. If you didn't get that initial role you wanted, keep the door open with that company so that when those new roles do come up or when circumstances do change you have already laid the ground to step into those new positions.

    Read the article

  • Your Job Search Should be More Than Just a New Year's Resolution

    - by david.talamelli
    I love the beginning of a new year, it is a great chance to refocus and either re-evaluate goals you are working to or even set new ones. I don't have any statistics to measure this but I am sure that one of the more popular new year's resolutions in the general workforce is to either get a new job or work to further develop one's career. I think this is a good idea, in today's competitive work force people should have a plan of what they want to do, what role they are after and how to get there. One common mistake I think many people make though is that a career plan shouldn't be a once a year thought. When people finish with the holiday season with their new year's resolution to find a new job fresh in their mind, you can see the enthusiasm and motivation a person has to make something happen. Emails are sent, calls are made, applications are made, networking is happening, etc..... Finding the right role that you are after however can be difficult, while it would be great if that dream role was available just at the time you happened to be looking for it - in reality this is not always the case. Job Seekers need to keep reminding themselves that while sometimes that dream job they are after is available at the same time they are looking, that also a Job search can be a difficult and long process. Many people who set out with the best of intentions in January to find a new job can soon lose interest in a job search if they do not immediately find a role. Just like the Christmas decorations are put away and the photos from New Year's are stored away - a Job Seeker's motivation may slowly decrease until that person finds themselves 12 months later in the same situation in same role and looking for that new opportunity again. Rather than just "going for it" and looking for a role in the month of January, a person's job search or career plan should be an ongoing activity and thought process that is constantly updated and evaluated over the course of the year. It can be hard to stay motivated over an extended period of time, especially when you are newly motivated and ready for that new role and the results are not immediate. Rather than letting your job search fall down the priority list and into the "too hard basket" a few ideas that may keep your enthusiasm fresh Update your resume every 6 months, even if you are not looking for a job - it is easy to forget what you have accomplished if you don't keep your details updated. Also it is good to be prepared and have a resume ready to go in case you do get an unexpected phone call for that 'dream job' you have been hoping for. Work out what you want out of your next role before you begin your job search - rather than aimlessly searching job ads or talking to people - think of the organisations or type of role you would like before you search. If you know what you are looking for it will be much easier to work out how to get there than if you do not know what you want. Don't expect immediate results once you decide to look for another job, things don't always fall into place. Timing and delivery can be important pieces of being selected for a role, companies don't hire every role in January. Have an open mind - people you meet or talk to may not result in immediate results for your job search but every connection may help you get a bit closer to what you are after . These actions will not guarantee a positive result, but in today's competitive work force every little of extra preparation and planning helps. All the best for 2011 and I hope your career plan whatever it may be is a success.

    Read the article

  • Salesforce.com s'attaque à Oracle avec Database.com, un service qui veut devenir « l'avenir des bases de données »

    Salesforce.com s'attaque à Oracle avec Database.com Une base de données 100 % hébergée qui veut révolutionner les SGBD Lors de sa conférence Dreamforce, qui se déroule actuellement à San Francisco, Salesforce.com, le plus célèbre éditeur de CRM en mode Cloud, vient de présenter un produit extrêmement ambitieux, qualifié par la société d'« avenir des bases de données ». Il s'agit de Database.com, le premier SGBD 100 % Cloud. La plate-forme veut supprimer les problématiques de l'optimisation et de la maintenance des bases de données et du matériel traditionnels. « Les bases de données Cloud représentent une opportunité majeure pour faciliter ...

    Read the article

  • Access violation when accessing a COM object from .Net

    - by Groo
    Dear Sirs, I am sorry if the post is too long, but I would be happy if someone would at least point read the bolded titles, and point me in the right direction. I am having this problem for couple of days, but was unable to found the answer on the net. These are the things I have found out so far. 1. "Access violation" exception crushes my managed application My C# WinForms app sometimes closes with an "Access violation" exception ("Attempted to read or write protected memory"), right in the moment when selecting a TabPage in a windows form TabControl. From the stack trace (try/catch around Application.Run) I can see that the exception happens at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg), called inside UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(Int32 dwComponentID, Int32 reason, Int32 pvLoopData). -- Message: Attempted to read or write protected memory. This is often an indication that other memory is corrupt. -- Stack trace: at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg) at System.Windows.Forms.Application.ComponentManager .System.Windows.Forms.UnsafeNativeMethods .IMsoComponentManager.FPushMessageLoop (Int32 dwComponentID, Int32 reason, Int32 pvLoopData) at System.Windows.Forms.Application.ThreadContext .RunMessageLoopInner(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.ThreadContext .RunMessageLoop(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.Run(ApplicationContext context) at MyApp.Program.Main() 2. The faulting module seems to be a COM object (ChartFX Client Server 6.2) Using WinDbg (with SoS loaded), I caught it on the unmanaged side, inside ChartFX.ClientServer.Core.dll (that's a COM charting component we are using): (ca84.c98c): Access violation - code c0000005 (first chance) First chance exceptions are reported before any exception handling. This exception may be expected and handled. eax=00000000 ebx=06e67c38 ecx=06e67c38 edx=000018c6 esi=06e7df30 edi=317a9e80 eip=31666110 esp=0015e040 ebp=0015e08c iopl=0 nv up ei pl zr na pe nc cs=001b ss=0023 ds=0023 es=0023 fs=003b gs=0000 efl=00010246 ChartFX_ClientServer_Core!Ordinal5507+0x97b7: 31666110 8a404d mov al,byte ptr [eax+4Dh] ds:0023:0000004d=?? [edit:] I also wasn't able to get the unmamanged stack details from WinDbg (it said "Stack unwind info not available"): 0:000 kP ChildEBP RetAddr WARNING: Stack unwind information not available. Following frames may be wrong. 0015e08c 3166288b ChartFX_ClientServer_Core!Ordinal5507+0x97b7 0015e394 3165a921 ChartFX_ClientServer_Core!Ordinal5507+0x5f32 0015e480 31678685 ChartFX_ClientServer_Core!Ordinal5496+0x26a 0015e568 3167bef4 ChartFX_ClientServer_Core!Ordinal5492+0x975 0015e668 316a356b ChartFX_ClientServer_Core!Ordinal5492+0x41e4 0015e77c 31709496 ChartFX_ClientServer_Core!Ordinal443+0x5745 0015e7d0 31707f70 ChartFX_ClientServer_Core!Ordinal2584+0x3cdc 0015e7f8 3170817d ChartFX_ClientServer_Core!Ordinal2584+0x27b6 0015e81c 3162fd76 ChartFX_ClientServer_Core!Ordinal2584+0x29c3 0015e86c 7719f8d2 ChartFX_ClientServer_Core!Ordinal899+0x6b6 0015e898 7719f794 USER32!GetMessageW+0x93 0015e910 771a06f6 USER32!GetWindowLongW+0x115 0015e940 771a069c USER32!CallWindowProcW+0x75 0015e960 747fcef4 USER32!CallWindowProcW+0x1b 0015e97c 747fd073 comctl32!Ordinal377+0x5c 0015e9e0 747fd027 comctl32!DefSubclassProc+0x92 0015ea04 747fd4e6 comctl32!DefSubclassProc+0x46 0015ea20 747fd073 comctl32!DefSubclassProc+0x505 0015ea84 747fd118 comctl32!DefSubclassProc+0x92 0015eae4 7719f8d2 comctl32!DefSubclassProc+0x137 3. Bug is not easy to reproduce (although it can be provoked usually in less than 5 min.) I have several Chart instances in several TabPages, and this usually happens while I am switching the tabs. I still don't know how to reproduce it, besides switching those tabs for several minutes before it happens, so I cannot use our source control to reliably find the build which didn't have this problem. I am accessing the charts through the managed AxChart wrapper class (derived from AxHost), which was created by VS designer automatically. 4. What should be my next step? If someone could point me to the next step I should do to find the actual cause, I would be very grateful. Experimenting (removing and returning code) does not do much good, because I don't know how to reproduce it, so it would take large amounts of time on each iteration just to convince myself that the bug is still there. I have found that people often suggest something like "switching compiler optimizations", but since the exception is not thrown deterministically, I don't want to simply rearrange some bytes and hope that it never returns. Thanks a lot in advance! Best regards, Groo

    Read the article

  • using return values from a c# .net made component build as com+

    - by YvesR
    Hello, so far I made a component in C# .NET 4 and use System.EnterpriseServices to make it COM visible. I want to develop business methods in C#, but I still need to access them from classic ASP (vbscript). So far so good, everything works fine (exept function overloading :)). Now I made a test class to get more expirience with return code. using System; using System.Collections.Generic; using System.Linq; using System.Text; using System.EnterpriseServices; using System.Management; namespace iController { /// /// The tools class provides additional functions for general use in out of context to other classes of the iController. /// public class tools :ServicedComponent { #region publich methods public bool TestBoolean() { return true; } public string TestString() { return "this is a string"; } public int TestInteger() { return 32; } public double TestDouble() { return 32.32; } public float TestFloat() { float ret = 2 ^ 16; return ret; } public string[] TestArray() { string[] ret = {"0","1"}; return ret; } public int[][] TestJaggedArray() { int[][] jaggedArray = new int[3][]; jaggedArray[0] = new int[] { 1, 3, 5, 7, 9 }; jaggedArray[1] = new int[] { 0, 2, 4, 6 }; jaggedArray[2] = new int[] { 11, 22 }; return jaggedArray; } public Dictionary<string, string> TestDictionary() { Dictionary<string, string> ret = new Dictionary<string,string>(); ret.Add("test1","val1"); ret.Add("test2","val2"); return ret; } #endregion } } Then I just made a simple vbscript file to run it with cscript.exe for testing porpuse. Dim oTools : Set oTools = CreateObject("iController.tools") WScript.StdOut.WriteLine TypeName(oTools.TestBoolean()) & " - " & oTools.TestBoolean() WScript.StdOut.WriteLine TypeName(oTools.TestString()) & " - " & oTools.TestString() WScript.StdOut.WriteLine TypeName(oTools.TestInteger()) & " - " & oTools.TestInteger() WScript.StdOut.WriteLine TypeName(oTools.TestDouble()) & " - " & oTools.TestDouble() WScript.StdOut.WriteLine TypeName(oTools.TestFloat()) & " - " & oTools.TestFloat() test = oTools.TestArray() WScript.StdOut.WriteLine TypeName(test) WScript.StdOut.WriteLine UBound(test) For i = 0 To UBound(test) WScript.StdOut.WriteLine test(i) Next For Each item IN test WScript.StdOut.WriteLine item Next test = oTools.TestJaggedArray() WScript.StdOut.WriteLine TypeName(test) For Each item IN test WScript.StdOut.WriteLine test & " - " & test.Item(item) Next test = oTools.TestDictionary() WScript.StdOut.WriteLine TypeName(test) For Each item IN test WScript.StdOut.WriteLine test & " - " & test.Item(item) Next What works fine: string, int, foat, double When it comes to array, jaggedarray or dictionaries I get a type mismatch. VarType is 13 object for the dictionary e.g. but this dict seems to be different then the Scripting.Dictionary. I checked codeproject.com and stackoverflow all day and didn't find any hints exept some thread on stackoverflow where someone mentioned there is a need to created a IDispatch interface. So anyone ever had the same issue and can help me or give me some hints I can go on with?

    Read the article

  • COM Add-in for Excel doesn't load when Excel is launched by opening file

    - by Nick Hebb
    Several users have reported that if they launch Excel by double-clicking an Excel file, the add-in will not load. But, if they open Excel via the Start menu (or Quick launch toolbar) the add-in loads fine. Some details, in case they help: It is a COM add-in, written in VB6. The problem has been reported on Windows XP/Excel 2003 and Vista/Excel 2007 systems. The add-in implements IDTExtensibility2. The start mode is set to "Load on Startup". Any thoughts on the cause or how to troubleshoot this would be greatly appreciated.

    Read the article

  • Retrieving the COM class factory for component with CLSID {XXXX} failed due to the following error:

    - by gopal
    I developed a Windows service using C#.NET to generate PDF report. To generate PDF file I am using a third party dll. The application is running in my Windows XP platform. When I deployed the service in Windows Server 2008 64 bit version, I got this error: Retrieving the COM class factory for component with CLSID {46521B1F-0A5B-4871-A4C2-FD5C9276F4C6} failed due to the following error: 80040154. I registered the DLL using the regsvr32 command. I able to see this CLSID in the registry. But the problem persists. What could be the problem?

    Read the article

  • Passing a SAFEARRAY from C# to COM

    - by SlavaGu
    I use 3rd party COM to find faces in a picture. One of the methods has the following signature, from SDK: long FindMultipleFaces( IUnknown* pIDibImage, VARIANTARG* FacePositionArray ); Parameters: pIDibImage[in] - The image to search. FacePositionArray[out]- The array of FacePosition2 objects into which face information is placed. This array is in a safe array (VARIANT) of type VT_UNKNOWN. The size of the array dictates the maximum number of faces for which to search. which translates into the following C# method signature (from metadata): int FindMultipleFaces(object pIDibImage, ref object pIFacePositions); Being optimistic I call it the following way but get an exception that the memory is corrupt. The exception is thrown only when a face is present in the image. FacePosition2[] facePositions = new FacePosition2[10]; object positions = facePositions; int faceCount = FaceLocator.FindMultipleFaces(dibImage, ref positions); What's the right way to pass SAFEARRAY to unmanaged code?

    Read the article

  • Installing a COM object without privileged access for use in Microsoft Office

    - by bmargulies
    Start with a series of MS Office extensions built in C++ as COM objects. Add a user who really badly wants to avoid the requirement of an installer with the necessary privileges to write to HKEY_CLASSES_ROOT. I've seem bits of evidence that MS has created some sort of trick for shadowing HKEY_CLASSES_ROOT from HKCU. Is this, in fact, possible? If so, can this be installed as a non-privileged MSI, or does it have to be arranged otherwise? And, finally, what's the minimum version of Windows required?

    Read the article

  • COM port cannot be opened in asp.net

    - by Pandiya Chendur
    I following this article for sending SMS it is a winform application.. I have referenced all the Dll's to my asp.net application..... I use an aspx page to detect a mobile device connected to a PC..... But it alwys shows COM 'n' Port could not be opened..... using SMS; using GsmComm.GsmCommunication; using GsmComm.PduConverter; public partial class _Default : System.Web.UI.Page { protected void Page_Load(object sender, EventArgs e) { GsmCommMain comm = new GsmCommMain(6, 9600, 300); comm.Open(); if (!comm.IsConnected()) { Response.Write("No Phone Connected"); } else { SmsSubmitPdu pdu = new SmsSubmitPdu("test", "+919999999999", ""); CommSetting.comm.SendMessage(pdu); } } }

    Read the article

  • How to test COM object integrity automatically?

    - by sharptooth
    Every COM object must have integrity. In simplified terms this means that if an object implements 3 interfaces - A, B and C and I have A* pointer to the object I must be able to successfully QueryInterface() both B and C and having B I must be able to retrieve A and C and having C I must be able to retrieve A and B. Now my object implements 5 interfaces and I want to test its integrity. Writing checks for all of the above myself will require a substantial effort. Is there a tool or some easily tweakable code or a code pattern that would do it?

    Read the article

  • Using DLL that using COM in C#

    - by chekalin-v
    I have been writing DLL on C++, that will be use in C#. DLL have some function, where I call hres = CoInitializeEx(NULL, COINIT_MULTITHREADED); and next call hres = CoInitializeSecurity( NULL, -1, // COM authentication NULL, // Authentication services NULL, // Reserved RPC_C_AUTHN_LEVEL_PKT, // Default authentication RPC_C_IMP_LEVEL_IMPERSONATE, // Default Impersonation NULL, // Authentication info EOAC_NONE, // Additional capabilities NULL // Reserved ); There are no error then I trying to use this dll in C++. But if I call function from DLL via C# application I see Error (80010106) Cannot change thread mode after it is set. I changed hres = CoInitializeEx(NULL, COINIT_MULTITHREADED); to hres = CoInitialize(NULL); After this changes error appear after CoInitializeSecurity: (80010119) Security must be initialized before any interfaces are marshalled or unmarshalled. It cannot be changed once initialized. How resolve this trouble?

    Read the article

  • Connect to a running instance of Visual Studio 2003 using COM, build and read output

    - by codeape
    For Visual Studio 6.0, I can connect to a running instance like: o = GetActiveObject("MSDev.Application") What prog ID do I use for Visual Studio 2003? How do I execute a 'Build Solution' once I have the COM object that references the VS2003 instance? How do I get the string contents of the build output window after executing the build solution command? Yes, I am aware that I can build a solution from the command line. But in this case, I need to connect to a running instance of Visual Studio. EDIT: found and submitted an answer, see below.

    Read the article

  • Handling events exposed on a .NET class via COM in VB6

    - by PeanutPower
    Handling events exposed on a .NET class via COM in VB6 My test .NET (class libary registered for interop in compiler settings) code: Imports System.Runtime.InteropServices <InterfaceType(ComInterfaceType.InterfaceIsIDispatch), ComVisible(True)> _ Public Interface MyEventInterface <DispId(1)> Event Exploded(ByVal Text As String) <DispId(2)> Sub PushRedButton() End Interface <ClassInterface(ClassInterfaceType.None)> _ Public Class EventTest Implements MyEventInterface Public Event Exploded(ByVal Text As String) Implements MyEventInterface.Exploded Public Sub PushRedButton() Implements MyEventInterface.PushRedButton RaiseEvent Exploded("Bang") End Sub End Class My test VB6 application winforms code (which references the above class libary): Public ct As New ComTest1.EventTest Private Sub Command1_Click() ct.add_Exploded (ExplodedHandler) ct.PushRedButton ct.remove_Exploded (ExplodedHandler) End Sub Private Sub ExplodedHandler(ByVal Text As String) MsgBox Text End Sub Specifially I'm not sure how to set up the handler in VB6 the compile error I get is "Argument not optional" on this line in the VB6: ct.add_Exploded (ExplodedHandler)

    Read the article

  • Access COM object through a windows process handle.

    - by Sivvy
    I'm currently automating an application at work using COM, and have an issue where anyone using my application has a problem if the original application is already open when my application runs. I know how to locate the process if it's open, but instead of having to worry about closing it, or working around it, etc., I want to try to use the existing application instead of opening a new one. This is how I normally start the application in my automation program: Designer.Application desApp = new Designer.Application(); Now I'm attempting to try and use the handle from an existing application: Designer.Application desApp = (Designer.Application)((System.Diagnostics.Process.GetProcessesByName("Designer.exe")[0]).Handle) (I know this doesn't work, since .Handle returns an IntPtr, but I'm using it as an example.) Is there any way to accomplish this? How do I return a usable object if I know the handle/process?

    Read the article

  • Mono ASP.NET COM Reference

    - by Benny
    I am sure this is a very dumb question to be asking for such a platform as Mono, but I am really stuck with .NET on one of my only remaining projects on MS platforms and would like to move away from it. The only problem is that the web site is dependent on a COM library that is simply a socket wrapper enforcing a messaging protocol. I could reverse the code (I actually made a 10k line attempt) but there's nothing better than the original if it works. Is there any way to reference a tlb export on Mono? Any advice would be greatly appreciated. Thanks in advance!

    Read the article

  • .NET interop COM DLL behaves differently in VB6 debugger

    - by Aheho
    I have a .NET v2.0 Dll that exposes a few classes to COM. The assembly is called BLogic.DLL I'm calling these classes from a legacy visual basic 6.0 application. I can generate and EXE file and if I have Blogic.dll in the same folder as the EXE, the program runs without a hitch. However If I try and launch the same program within the VB6 debugger I get a: Automation Error The system cannot find the file specified I assume when I'm running in the debugger, the PLogic.dll file can't be found. I tried putting it in the System32 folder, and the same folder as the VB6.EXE file, but I still get the same error. Other facts that may help: PLogic.dll is NOT a strongly-named assembly. It depends on a 3rd party reference that isn't strongly signed so VS doesn't let me strongly sign it. However the 3rd party functionality isn't being called by the VB6 code, and it is not ComVisible.

    Read the article

  • Connect to an elevated COM server from a non-elevated process

    - by JS Bangs
    We have a program which launches a child process that hosts a local COM server, which for various reasons must be launched elevated. Everything works fine so long as both the parent and the child process are elevated. However, we also want to run when the parent process is non-elevated. Launching the child process results in a UAC dialog (which is acceptable), and the child appears to start correctly and successfully calls CoRegisterClassObject. However, the parent process gets REGDB_E_CLASSNOTREG when calling CoCreateInstance with the same CLSID. I assume this is some sort of permissions issue. How can I register my class in the elevated server to allow it to be called from a non-elevated process.

    Read the article

  • .NET Compact COM interoperability

    - by markhor
    I have the following code in a full .NET framework solution: public delegate int CreateObjectDelegate( [In] ref Guid classID, [In] ref Guid interfaceID, [MarshalAs(UnmanagedType.Interface)] out object outObject); ... var createObject = (NativeMethods.CreateObjectDelegate) Marshal.GetDelegateForFunctionPointer( NativeMethods.GetProcAddress(_modulePtr, "CreateObject"), typeof (NativeMethods.CreateObjectDelegate)); object result; Guid interfaceId = _guid; Guid classID = _classId; createObject(ref classID, ref interfaceId, out result); The purpose is to create the needed COM object at runtime. Is it possible with any .NET compact framework? Note that it doesn't have Marshal.GetDelegateForFunctionPointer.

    Read the article

< Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >