Search Results

Search found 31716 results on 1269 pages for 'default action'.

Page 14/1269 | < Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >

  • Automatically Reset Theme To Default, SharePoint 2010

    - by KunaalKapoor
    Manually/Through UIOn the top link bar, click Site Settings.On the Site Management page, in the Customization section, click Apply theme to site.On the Apply Theme to Web Site page, select No Theme(Default) from the list.Click Apply.Through Scriptfunction Apply-SPDefaultTheme([string]$SiteUrl, [string]$webName){$site = new-object Microsoft.SharePoint.SPSite($SiteUrl)$web = $site.OpenWeb($webName)$theme = [Microsoft.SharePoint.Utilities.ThmxTheme]::RemoveThemeFromWeb($web,$false)$web.Update()$web.Dispose()$site.Dispose()}After looking in the SPTHEMES.XML file found in the C:\Program Files\Common Files\Microsoft Shared\Web Server Extensions\14\TEMPLATE\LAYOUTS\1033 folder, you do see there is a theme with a theme name of "none". Since there is no "default" theme in 2010. So make sure if you wanna reset it to default you know that there is no default, you need to select 'none' :)

    Read the article

  • Maintaining SQL Server default trace historical events for analysis and reporting

    I often see questions online where someone wants to find out who started a trace, when tempdb last had an autogrow event, or when the last full backup for master occurred. Since these and other events are captured by the default trace, but the default trace only keeps five 20MB rollover files by default. This means that the event you are after may no longer be there, depending on how long ago it was and how busy your server happens to be. Unfortunately, people often need to find this information well after the fact.

    Read the article

  • Problem playing repeat animation/action?

    - by Beast
    I'm calling this function on multiple sprites after checking numberOfRunningActions()"to play same animation but it's not working only the first tagged sprite plays the animation. What am I doing wrong? void CGame::playAnimation(const char* filename, int tag, CCLayer* target) { CCAnimation* animation = CCAnimation::animation(); CCSprite* spriteSheet = CCSprite::spriteWithFile(filename); for(int i = 0; i < spriteSheet->getTexture()->getPixelsWide()/SIZE; i++) // SIZE is an int value { animation->addFrameWithTexture(spriteSheet->getTexture(), CCRect(SIZE * i, 0, SIZE, SIZE)); } CCActionInterval* action = CCAnimate::actionWithDuration(1, animation, true); CCRepeatForever* repeatAction = CCRepeatForever::actionWithAction(action); target->getChildByTag(tag)->runAction(repeatAction); }

    Read the article

  • How can I open Outlook Calendar to a 2-3 week view by default?

    - by Simon
    I use Outlook 2007, and I like to view my calendar 2 (or sometimes 3) weeks at a time. Its relatively easy to do, by dragging my mouse across several weeks in the mini calendar. BUT... it never stays that way. As soon as I change to Contacts and back to Calendar, the view resets to showing a whole month. Any ideas about how to change to default view?

    Read the article

  • I've set an editor as default, how do I call it to open files in a shell?

    - by iight
    EDIT I thought of a better way to phrase the question. How can I find the alias that Ubuntu is using for a different text editor? Rather than using nano by typing nano file.txt, i'd like to be able to type sublime file.txt to open sublime editor. I don't know where to look to find these aliases. sudo update-alternatives --config editor does not show it as a choice, I only see the 'default' editors, like Nano and vim.tiny.

    Read the article

  • Which registry keys need to be edited to change the default browser?

    - by paradroid
    Which registry keys need to be edited to change the default browser? I have found these keys so far and they seem to do what I want, but I am not sure if I have found all of them: Data in: HKEY_CURRENT_USER\Software\Classes\http\shell\open\command HKEY_CURRENT_USER\Software\Classes\https\shell\open\command HKEY_CURRENT_USER\Software\Classes\ftp\shell\open\command Value in: HKEY_CURRENT_USER\Software\Classes\Local Settings\Software\Microsoft\Windows\Shell\MuiCache Are there any other keys which would need to be changed, so that it is done perfectly?

    Read the article

  • Is it possible to set a default behaviour for custom (non-native) methods/functions in Java?

    - by Tom
    Is it possible to set a default behaviour for custom (non-native) methods/functions in Java? For example, I would like to change the default "Function" to do a System.out.println("message") whenever called. So, when a custom method/function is being created: public String testMethod() { //custom code } it should execute the newly added default behaviour (in this case the system output), before the custom code is run. Even if this would be a bad excercise, is it possible? Maybe by extending the function class or something?

    Read the article

  • Networking conflict - What is the most common default computer name for Windows?

    - by John
    I recently had to change the name of my computer to log onto a public wi-fi spot, because a computer with my name was already logged on. (I asked a guy there what to do after it said there was already a computer named "(omitted)" logged on.) I've never been at a wifi spot you had to log into before. I didn't even notice what the computer's name was before. My question is what are the most common default computer names. I'm curious. How often does this sort of problem happen? (For some reason my previous post was closed as off topic - so now I included the reason I'm asking. If it's still considered off topic (networking conflicts) I'll take it elsewhere, but the other forums I know of (ehow.com, answers.yahoo.com) are full of people that couldn't begin to answer a question like this.) Thanks.

    Read the article

  • Networking conflict - What is the most common default computer name for Windows?

    - by John
    I recently had to change the name of my computer to log onto a public wi-fi spot, because a computer with my name was already logged on. (I asked a guy there what to do after it said there was already a computer named "(omitted)" logged on.) I've never been at a wifi spot you had to log into before. I didn't even notice what the computer's name was before. My question is what are the most common default computer names. I'm curious. How often does this sort of problem happen? (For some reason my previous post was closed as off topic - so now I included the reason I'm asking. If it's still considered off topic (networking conflicts) I'll take it elsewhere, but the other forums I know of (ehow.com, answers.yahoo.com) are full of people that couldn't begin to answer a question like this.) Thanks.

    Read the article

  • Zend Partial + Zend Action Helper causes an additional request to bootstrap?

    - by AndreLiem
    I've been profiling some zend framework code with webgrind to see where some bottle necks are and I'm noticing some very odd behavior. Using the zend partial for example, if I pass a variable value that comes from a zend action helper, it results in two requests being made. in sample.phtml echo $this->partial('partial/embed.phtml', array('url' => $this->url)); in indexcontroller.php $this->view->url = $this->_helper->Embed()->url; But if I don't pass the value from the helper to the partial, but still run the helper, it only makes one request in webgrind. e.g. $this->view->url = 'test'; $this->_helper->Embed()->url; Does anybody know why this could be happening? Am I potentially interpreting web grind incorrectly, or is it really calling the bootstrap twice when the an action helper value is tied to a partial? I'm starting to realize how inefficient some components of Zend are. Thanks

    Read the article

  • C#/.NET Little Wonders: Comparer&lt;T&gt;.Default

    - by James Michael Hare
    I’ve been working with a wonderful team on a major release where I work, which has had the side-effect of occupying most of my spare time preparing, testing, and monitoring.  However, I do have this Little Wonder tidbit to offer today. Introduction The IComparable<T> interface is great for implementing a natural order for a data type.  It’s a very simple interface with a single method: 1: public interface IComparer<in T> 2: { 3: // Compare two instances of same type. 4: int Compare(T x, T y); 5: }  So what do we expect for the integer return value?  It’s a pseudo-relative measure of the ordering of x and y, which returns an integer value in much the same way C++ returns an integer result from the strcmp() c-style string comparison function: If x == y, returns 0. If x > y, returns > 0 (often +1, but not guaranteed) If x < y, returns < 0 (often –1, but not guaranteed) Notice that the comparison operator used to evaluate against zero should be the same comparison operator you’d use as the comparison operator between x and y.  That is, if you want to see if x > y you’d see if the result > 0. The Problem: Comparing With null Can Be Messy This gets tricky though when you have null arguments.  According to the MSDN, a null value should be considered equal to a null value, and a null value should be less than a non-null value.  So taking this into account we’d expect this instead: If x == y (or both null), return 0. If x > y (or y only is null), return > 0. If x < y (or x only is null), return < 0. But here’s the problem – if x is null, what happens when we attempt to call CompareTo() off of x? 1: // what happens if x is null? 2: x.CompareTo(y); It’s pretty obvious we’ll get a NullReferenceException here.  Now, we could guard against this before calling CompareTo(): 1: int result; 2:  3: // first check to see if lhs is null. 4: if (x == null) 5: { 6: // if lhs null, check rhs to decide on return value. 7: if (y == null) 8: { 9: result = 0; 10: } 11: else 12: { 13: result = -1; 14: } 15: } 16: else 17: { 18: // CompareTo() should handle a null y correctly and return > 0 if so. 19: result = x.CompareTo(y); 20: } Of course, we could shorten this with the ternary operator (?:), but even then it’s ugly repetitive code: 1: int result = (x == null) 2: ? ((y == null) ? 0 : -1) 3: : x.CompareTo(y); Fortunately, the null issues can be cleaned up by drafting in an external Comparer.  The Soltuion: Comparer<T>.Default You can always develop your own instance of IComparer<T> for the job of comparing two items of the same type.  The nice thing about a IComparer is its is independent of the things you are comparing, so this makes it great for comparing in an alternative order to the natural order of items, or when one or both of the items may be null. 1: public class NullableIntComparer : IComparer<int?> 2: { 3: public int Compare(int? x, int? y) 4: { 5: return (x == null) 6: ? ((y == null) ? 0 : -1) 7: : x.Value.CompareTo(y); 8: } 9: }  Now, if you want a custom sort -- especially on large-grained objects with different possible sort fields -- this is the best option you have.  But if you just want to take advantage of the natural ordering of the type, there is an easier way.  If the type you want to compare already implements IComparable<T> or if the type is System.Nullable<T> where T implements IComparable, there is a class in the System.Collections.Generic namespace called Comparer<T> which exposes a property called Default that will create a singleton that represents the default comparer for items of that type.  For example: 1: // compares integers 2: var intComparer = Comparer<int>.Default; 3:  4: // compares DateTime values 5: var dateTimeComparer = Comparer<DateTime>.Default; 6:  7: // compares nullable doubles using the null rules! 8: var nullableDoubleComparer = Comparer<double?>.Default;  This helps you avoid having to remember the messy null logic and makes it to compare objects where you don’t know if one or more of the values is null. This works especially well when creating say an IComparer<T> implementation for a large-grained class that may or may not contain a field.  For example, let’s say you want to create a sorting comparer for a stock open price, but if the market the stock is trading in hasn’t opened yet, the open price will be null.  We could handle this (assuming a reasonable Quote definition) like: 1: public class Quote 2: { 3: // the opening price of the symbol quoted 4: public double? Open { get; set; } 5:  6: // ticker symbol 7: public string Symbol { get; set; } 8:  9: // etc. 10: } 11:  12: public class OpenPriceQuoteComparer : IComparer<Quote> 13: { 14: // Compares two quotes by opening price 15: public int Compare(Quote x, Quote y) 16: { 17: return Comparer<double?>.Default.Compare(x.Open, y.Open); 18: } 19: } Summary Defining a custom comparer is often needed for non-natural ordering or defining alternative orderings, but when you just want to compare two items that are IComparable<T> and account for null behavior, you can use the Comparer<T>.Default comparer generator and you’ll never have to worry about correct null value sorting again.     Technorati Tags: C#,.NET,Little Wonders,BlackRabbitCoder,IComparable,Comparer

    Read the article

  • How can I change the default program installation directory in Windows 7?

    - by Max
    Windows 7 is installed on my C drive, which is quite small. I am very tired of instructing new programs to put their files on my larger D drive during installation; I would like to change the default drive. This article says that you can use a registry hack, but I am giving Microsoft the benefit of the doubt and naively assuming that a configuration option exists somewhere. It's 2010... do I really have to hack my registry to make a simple tweak like this? Also, there's a ServerFault question that explains how to move the "Users" directory and create a symlink, which could also work. However, at the moment I have some apps in C:\Program Files, some apps in C:\Program Files (x86), and some apps in the corresponding folders on D:\, so it would be a hassle. Also, my small OS boot drive is a 10k RPM WD Raptor, and I feel like that probably gives a speed boost to apps installed on it that need to read & write to their directories a bunch. I wonder if it actually matters.

    Read the article

  • Action button: only true once per press

    - by Sidar
    I'm using SFML2.0 and am trying to make a wrapper class for my controller/joystick. I read all the input data from my controller and send it off to my controllable object. I want to have two types of buttons per button press, one that is continues(true false state ) and one that is an action and is set to false after the next frame update. Here is an example of how I set my button A to true or false with the SFML api. Whereas data is my struct of buttons, and A holds my true/false state every update. data.A = sf::Joystick::isButtonPressed(i,st::input::A); But I've also added "data.actionA" which represents the one time action state. Basically what I want is for actionA to be set false after the update its been set to true. I'm trying to keep track of the previous state. But I seem to fall into this loop where it toggles between true and false every update. Anyone an idea? Edit: Since I can't answer my own question yet here is my solution: data.actionA = data.A = sf::Joystick::isButtonPressed(i,st::input::A); if(prev.A) data.actionA = false; First I always set the actionA to the value of the button state. Then I check if the previous state of A is true. If so we negate the value.

    Read the article

  • SATA errors reported during boot: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0

    - by digby280
    I have noticed some error during the Linux boot. They seem to continue to occur after the boot adding lines to the log every few seconds. Once booted this normally does not appear to be causing any problems. However, around 1 in 10 boots results in a kernel panic and the computer has on two or three occasions suddenly rebooted after being powered on for a number of hours. I presume the cause of the reboot is a kernel panic as well. I am running Ubuntu 11.10 and I have had Ubuntu installed on the computer for around a year. I have googled around and not found anything useful. I have provided the kernel log lines and the output of smartctl. Can anyone explain exactly what these errors mean, or better still how to resolve them? Apr 2 16:51:27 dell580 kernel: [ 19.831140] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:27 dell580 kernel: [ 19.934194] tg3 0000:03:00.0: eth0: Link is down Apr 2 16:51:28 dell580 kernel: [ 20.929468] tg3 0000:03:00.0: eth0: Link is up at 100 Mbps, full duplex Apr 2 16:51:28 dell580 kernel: [ 20.929471] tg3 0000:03:00.0: eth0: Flow control is on for TX and on for RX Apr 2 16:51:28 dell580 kernel: [ 20.929727] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready Apr 2 16:51:29 dell580 kernel: [ 21.609381] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:29 dell580 kernel: [ 21.616515] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:29 dell580 kernel: [ 21.616519] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:29 dell580 kernel: [ 21.616525] ata2.00: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 21.934036] ata2.01: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 22.408890] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.408907] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.440934] ata2.00: configured for UDMA/100 Apr 2 16:51:29 dell580 kernel: [ 22.449040] ata2.01: configured for UDMA/133 Apr 2 16:51:29 dell580 kernel: [ 22.449818] ata2: EH complete Apr 2 16:51:33 dell580 kernel: [ 26.122664] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:33 dell580 kernel: [ 26.122670] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:33 dell580 kernel: [ 26.122677] ata2.00: hard resetting link Apr 2 16:51:33 dell580 kernel: [ 26.442684] ata2.01: hard resetting link Apr 2 16:51:34 dell580 kernel: [ 26.925545] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.925561] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.961542] ata2.00: configured for UDMA/100 Apr 2 16:51:34 dell580 kernel: [ 26.969616] ata2.01: configured for UDMA/133 Apr 2 16:51:34 dell580 kernel: [ 26.970400] ata2: EH complete Apr 2 16:51:35 dell580 kernel: [ 28.111180] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:35 dell580 kernel: [ 28.111184] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:35 dell580 kernel: [ 28.111191] ata2.00: hard resetting link Apr 2 16:51:35 dell580 kernel: [ 28.429674] ata2.01: hard resetting link Apr 2 16:51:36 dell580 kernel: [ 28.904557] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.904572] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.936609] ata2.00: configured for UDMA/100 Apr 2 16:51:36 dell580 kernel: [ 28.944692] ata2.01: configured for UDMA/133 Apr 2 16:51:36 dell580 kernel: [ 28.945464] ata2: EH complete Apr 2 16:51:38 dell580 kernel: [ 31.581756] eth0: no IPv6 routers present Apr 2 16:51:38 dell580 kernel: [ 32.103066] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:38 dell580 kernel: [ 32.103074] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:38 dell580 kernel: [ 32.103085] ata2.00: hard resetting link Apr 2 16:51:38 dell580 kernel: [ 32.419669] ata2.01: hard resetting link Apr 2 16:51:39 dell580 kernel: [ 32.894518] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.894533] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.926536] ata2.00: configured for UDMA/100 Apr 2 16:51:39 dell580 kernel: [ 32.934715] ata2.01: configured for UDMA/133 Apr 2 16:51:39 dell580 kernel: [ 32.935578] ata2: EH complete Here's the output of smartctl for the drive. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.0.0-17-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT Device Model: SAMSUNG HD103UJ Serial Number: S13PJ90QC19706 LU WWN Device Id: 5 0000f0 00b1c7960 Firmware Version: 1AA01113 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3b Local Time is: Mon Apr 2 17:13:48 2012 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 41) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: (11772) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 197) minutes. Conveyance self-test routine recommended polling time: ( 21) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 076 076 011 Pre-fail Always - 7940 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 521 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 642 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 482 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 759 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 073 069 000 Old_age Always - 27 (Min/Max 16/27) 194 Temperature_Celsius 0x0022 073 067 000 Old_age Always - 27 (Min/Max 16/28) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 320028 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 099 099 000 Old_age Always - 1494 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 211 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 211 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 0f 31 63 8f e1 Error: ICRC, ABRT 15 sectors at LBA = 0x018f6331 = 26174257 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 40 62 8f e1 08 00:01:00.460 READ DMA c8 00 20 00 7c 30 e0 08 00:01:00.450 READ DMA c8 00 00 10 49 8f e1 08 00:01:00.440 READ DMA c8 00 e0 20 d0 30 e0 08 00:01:00.420 READ DMA c8 00 00 c0 59 90 e1 08 00:01:00.400 READ DMA Error 210 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 cf e9 cf 66 e0 Error: ICRC, ABRT 207 sectors at LBA = 0x0066cfe9 = 6737897 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 b8 cf 66 e0 08 00:08:29.780 READ DMA c8 00 60 60 c9 18 e0 08 00:08:29.770 READ DMA c8 00 40 20 c9 18 e0 08 00:08:29.770 READ DMA c8 00 20 00 c9 18 e0 08 00:08:29.760 READ DMA c8 00 20 98 cf 66 e0 08 00:08:29.750 READ DMA Error 209 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 2f d1 74 e0 e0 Error: ICRC, ABRT 47 sectors at LBA = 0x00e074d1 = 14709969 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 00 74 e0 e0 08 00:00:30.940 READ DMA c8 00 20 18 36 de e0 08 00:00:30.930 READ DMA c8 00 08 48 f1 dd e0 08 00:00:30.930 READ DMA c8 00 08 a8 f0 dd e0 08 00:00:30.930 READ DMA c8 00 08 90 f0 dd e0 08 00:00:30.930 READ DMA Error 208 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 7f 21 88 9d e0 Error: ICRC, ABRT 127 sectors at LBA = 0x009d8821 = 10324001 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 a0 00 88 9d e0 08 00:00:27.610 READ DMA c8 00 58 a8 e7 9c e0 08 00:00:27.610 READ DMA c8 00 00 28 e6 9c e0 08 00:00:27.610 READ DMA c8 00 00 e0 e4 9c e0 08 00:00:27.610 READ DMA c8 00 00 90 e0 9c e0 08 00:00:27.600 READ DMA Error 207 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 26 6a 6a c3 e0 Error: ABRT at LBA = 0x00c36a6a = 12806762 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ca 00 00 90 69 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 68 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 50 65 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 d0 64 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 63 c3 e0 08 00:29:39.350 WRITE DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Interrupted (host reset) 90% 638 - # 2 Short offline Interrupted (host reset) 90% 638 - # 3 Extended offline Interrupted (host reset) 90% 638 - # 4 Short offline Interrupted (host reset) 90% 638 - # 5 Extended offline Interrupted (host reset) 90% 638 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • How to declare a Generics Action in struts2.xml file ?

    - by Rasatavohary
    Hi everyone, My problems is in a Struts2 action, where I have a class : public class MyAction<T> extends ActionSupport with a private member like this : private T myData; And I would like to declare this aciton in the struts.xml file, how can i manage to do so ? Thanks for the answer. Ps : I've tried without declaration of T, but it did not work

    Read the article

  • Opening the Internet Settings Dialog and using Windows Default Network Settings via Code

    - by Rick Strahl
    Ran into a question from a client the other day that asked how to deal with Internet Connection settings for running  HTTP requests. In this case this is an old FoxPro app and it's using WinInet to handle the actual HTTP connection. Another client asked a similar question about using the IE Web Browser control and configuring connection properties. Regardless of platform or tools used to do HTTP connections, you can probably configure custom connection and proxy settings in your application to configure http connection settings manually. However, this is a repetitive process for each application requires you to track system information in your application which is undesirable. Often it's much easier to rely on the system wide proxy settings that Windows provides via the Internet Settings dialog. The dialog is a Control Panel applet (inetcpl.cpl) and is the same dialog that you see when you pop up Internet Explorer's Options dialog: This dialog controls the Windows connection properties that determine how the Windows HTTP stack connects to the Internet and how Proxy's are used if configured. Depending on how the HTTP client is configured - it can typically inherit and use these global settings. Loading the Settings Dialog Programmatically The settings dialog is a Control Panel applet with the name of: inetcpl.cpl and you can use any Shell execution mechanism (Run dialog, ShellExecute API, Process.Start() in .NET etc.) to invoke the dialog. Changes made there are immediately reflected in any applications that use the default connection settings. In .NET you can simply do this to bring up the Internet Settings dialog with the Connection tab enabled: Process.Start("inetcpl.cpl",",4"); In FoxPro you can simply use the RUN command to execute inetcpl.cpl: lcCmd = "inetcpl.cpl ,4" RUN &lcCmd Using the Default Connection/Proxy Settings When using WinInet you specify the Http connect type in the call to InternetOpen() like this (FoxPro code here): hInetConnection=; InternetOpen(THIS.cUserAgent,0,; THIS.chttpproxyname,THIS.chttpproxybypass,0) The second parameter of 0 specifies that the default system proxy settings should be used and it uses the settings from the Internet Settings Connections tab. Other connection options for HTTP connections include 1 - direct (no proxies and ignore system settings), 3 - explicit Proxy specification. In most situations a connection mode setting of 0 should work. In .NET HTTP connections by default are direct connections and so you need to explicitly specify a default proxy or proxy configuration to use. The easiest way to do this is on the application level in the config file: <configuration> <system.net> <defaultProxy> <proxy bypassonlocal="False" autoDetect="True" usesystemdefault="True" /> </defaultProxy> </system.net> </configuration> You can do the same sort of thing in code specifying the proxy explicitly and using System.Net.WebProxy.GetDefaultProxy(). So when making HTTP calls to Web Services or using the HttpWebRequest class you can set the proxy with: StoreService.Proxy = WebProxy.GetDefaultProxy(); All of this is pretty easy to deal with and in my opinion is a way better choice to managing connection settings than having to track this stuff in your own application. Plus if you use default settings, most of the time it's highly likely that the connection settings are already properly configured making further configuration rare.© Rick Strahl, West Wind Technologies, 2005-2011Posted in Windows  HTTP  .NET  FoxPro   Tweet (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

< Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >