Search Results

Search found 2059 results on 83 pages for 'tan ce'.

Page 14/83 | < Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >

  • SQL Server Compact 'Data Directory' macro in Connection String - more info needed

    - by codeulike
    So, as described on this msdn page, when you define a Connection String for SQL Server Compact 3.5, you can use the "Data Directory" macro, like this: quote from this msdn page: Data Directory Support SQL Server Compact 3.5 now supports the Data Directory macro. This means that if you add the string |DataDirectory| (enclosed in pipe symbols) to a file path, it will resolve to the path of the database. For example, consider the connection string: "Data Source= c:\program files\MyApp\Mydb.sdf" When using Data Directory, you can instead use the following connection string: "Data Source = |DataDirectory|\Mydb.sdf" For more information, see How to: Deploy a SQL Server Compact 3.5 Database with an Application. However, the 'for more information' link on msdn doesn't actually give any more information. So my question is: How does the |Data Directory| macro translate at run time? For WinForm apps, it seems to just give the location of the executable. Or is it more complicated than that?

    Read the article

  • Sync a WinForm with DatagridView

    - by Ruben Trancoso
    I have a Form with a DataGridView which DataSource is a BindingSource to a table. This view will have a single row selection and a button to delete, edit the current selected row in a popup Form and a insert button that will use the same Form as well. My question is how can I sync the pop Form with the current row? I tryied to use the RowStateChanged event to get and store the current selected Row to be used in the Form but I coudnt. After the event I get the row that was selected before. Other thing I dont understand yet in C# how to have a single recordSet and know wich is the current record even if its a new being inserted in a way that once in the Form all data being entered will show up at the same time in the DataGridView.

    Read the article

  • Why won't my program terminate?

    - by Qwertie
    I have a .NET Compact Framework app that can runs on three windows machines (Desktop windows and two WinCE machines) and on the WinCE devices, the process never terminates on exit, even if I call Application.Exit(). Besides .NET, it uses one COM component (which does everything on the UI thread). If I break into the debugger after exitting, Visual Studio shows only one thread and a completely blank call stack. What could possibly cause this? Update: My process is terminating on the desktop but not the WinCE machines. I tried to force the process to terminate with the following code, but it doesn't work: [DllImport("coredll.dll")] static extern int TerminateProcess(IntPtr hProcess, uint uExitCode); static public void ExitProcess() { if (Platform.IsWindowsCE) TerminateProcess(new IntPtr(-1), 0); Application.Exit(); } There are also supposed to be ExitProcess() and GetCurrentProcess() APIs like the following, but if I try to call them, I get EntryPointNotFoundException. Therefore I am using TerminateProcess(-1, 0) because the documentation for the desktop version of GetCurrentProcess claims that it simply returns -1. [DllImport("coredll.dll")] static extern int ExitProcess(IntPtr hProcess); [DllImport("coredll.dll")] static extern IntPtr GetCurrentProcess(); Even if I do this: static public void ExitProcess() { if (Platform.IsWindowsCE) TerminateProcess(new IntPtr(-1), 0); Application.Exit(); throw new Exception("Trying to force quit."); } A fatal error dialog appears with a helpful "Quit" button, but pushing the button still does not cause the process to terminate on either machine!

    Read the article

  • [sql server 2005]how to list all table name in T-SQL

    - by shrimpy
    SELECT name FROM sys.databases -- this can list all database name in the server user database SELECT * FROM INFORMATION_SCHEMA.TABLES -- these two line can list the table for one particular database but how to do something in order can have the result like the following Database Table --------- ------------- db1 t1 db1 t2 db2 t1 ... ... -thx

    Read the article

  • Does CeRunAppAtTime work?

    - by Sandeep
    I have been at this thing for a couple of days and I just can't see CeRunAppAtTime working. I just want to ask if anyone has ever got his to work? Could anyone please post a working code sample. Sandeep

    Read the article

  • SQLCE 3.5 FIPS compliance on Windows Mobile 6.0

    - by trampster
    What is a positions of SQLCE 3.5 when running on Windows Mobile 6.0 in relation to FIPS compliance. I have read lots of differing reports on this and need a definitive answer, one which comes from a reliable source (please provide links) I have read this "The encryption modes in SQL Server Compact 3.5 are FIPS complaint if FIPS mode is enabled at the OS level." Is this true? if so how does one enable it at the OS level.

    Read the article

  • SQL Server Compact timed out waiting for a lock

    - by jankhana
    Hi all, I'm having an application in that i use Sql Compact 3.5 with VS2008. I'm running multiple threads in my application which contacts the compact database and accesses the row. It selects and deletes those rows in a fashion i.e selecting and giving to the application 5 rows and deleting those rows from the table. It works great with a single thread but if i use multiple threads i.e if 3 or more threads are running I get very often the TimeOut Error!!! I have increased the Time out property in the connection string but it didn't give me expected result. The error log is as follow: SQL Server Compact timed out waiting for a lock. The default lock time is 2000ms for devices and 5000ms for desktops. The default lock timeout can be increased in the connection string using the ssce: default lock timeout property. [ Session id = 5,Thread id = 4204,Process id = 4808,Table name = XXX,Conflict type = x lock (s blocks),Resource = TAB ] The Query that I use to retrieve is as follows: " select Top(5) * from TableName order by id; delete from TableName where id in(select top(5) id from TableName order by id); " Is there any way by which we can avoid this Time Out exception??????? The above query I un as a transaction in VS2008 one using SQLCECommand and the other using SqlCEDataAdapter. Any Idea!!!!!! Reply

    Read the article

  • Very interesting problem in Compact Framework

    - by Alexander
    Hi, i have a performance problem while inserting data to sqlce.I'm reading string and making inserts to My tables.In LU_MAM table,i insert 1000 records withing 8 seconds.After Mam tables i make some inserts but my largest table is CR_MUS.When i want to insert record into CR_MUS,it takes too much time.CR_MUS has 2000 records and insert takes 35 seconds.What can be reason?I use same logic in my insert functions.Do u have any idea?I use VS 2008 sp1. Dim reader As StringReader reader = New StringReader(data) cn = New SqlCeConnection(General.ConnString) cn.Open() If myTransfer.ClearTables(cn, cmd) = True Then progress = 0 '------------------------------------------ cmd = New SqlServerCe.SqlCeCommand Dim rs As SqlCeResultSet cmd.Connection = cn cmd.CommandType = CommandType.TableDirect Dim rec As SqlCeUpdatableRecord ' name of table While reader.Peek > -1 If strerr_col = "" Then satir = reader.ReadLine() ayrac = Split(satir, "|") If ayrac(0).ToString() = "LC" Then prgsbar.Maximum = Convert.ToInt32(ayrac(1)) ElseIf ayrac(0).ToString = "PPAR" Then . If ayrac(2).ToString <> General.PMVer Then ShowWaitCursor(False) txtDurum.Text = "Wrong Version" Exit Sub End If If p_POCKET_PARAMETERS = True Then cmd.CommandText = "POCKET_PARAMETERS" txtDurum.Text = "POCKET_PARAMETERS" rs = cmd.ExecuteResultSet(ResultSetOptions.Updatable) rec = rs.CreateRecord() p_POCKET_PARAMETERS = False End If strerr_col = myVERI_AL.POCKET_PARAMETERS_I(ayrac, cmd, rs, rec) prgsbar.Value += 1 ElseIf ayrac(0).ToString() = "MAM" Then If p_LU_MAM = True Then txtDurum.Text = "LU_MAM " cmd.CommandText = "LU_MAM" rs = cmd.ExecuteResultSet(ResultSetOptions.Updatable) rec = rs.CreateRecord() p_LU_MAM = False End If strerr_col = myVERI_AL.LU_MAM_I(ayrac, cmd, rs, rec) prgsbar.Value += 1 ElseIf ayrac(0).ToString = "KMUS" Then If p_CR_MUS = True Then cmd.CommandText = "CR_MUS" txtDurum.Text = "CR_MUS" rs = cmd.ExecuteResultSet(ResultSetOptions.Updatable) rec = rs.CreateRecord() p_TR_KAMPANYA_MALZEME = False End If strerr_col = myVERI_AL.CR_MUS_I(ayrac, cmd, rs, rec) prgsbar.Value += 1 end while Public Function CR_KAMPANYA_MUSTERI_I(ByVal f_Line() As String, ByRef myComm As SqlCeCommand, ByRef rs As SqlCeResultSet, ByRef rec As SqlCeUpdatableRecord) As String Try rec.SetValue(0, If(f_Line(1) = String.Empty, DirectCast(DBNull.Value, Object), f_Line(1))) rec.SetValue(1, If(f_Line(2) = String.Empty, DirectCast(DBNull.Value, Object), f_Line(2))) rec.SetValue(2, If(f_Line(3) = String.Empty, DirectCast(DBNull.Value, Object), f_Line(3))) rec.SetValue(3, If(f_Line(5) = String.Empty, DirectCast(DBNull.Value, Object), f_Line(5))) rec.SetValue(4, If(f_Line(6) = String.Empty, DirectCast(DBNull.Value, Object), f_Line(6))) rs.Insert(rec) Catch ex As Exception strerr_col = ex.Message End Try Return strerr_col End Function

    Read the article

  • SqlCe odd results why? -- Same SQL, different results in different apps. Issue with

    - by NitroxDM
    When I run this SQl in my mobile app I get zero rows. select * from inventory WHERE [ITEMNUM] LIKE 'PUMP%' AND [LOCATION] = 'GARAGE' When I run the same SQL in Query Analyzer 3.5 using the same database I get my expected one row. Why the difference? Here is the code I'm using in the mobile app: SqlCeCommand cmd = new SqlCeCommand(Query); cmd.Connection = new SqlCeConnection("Data Source="+filePath+";Persist Security Info=False;"); DataTable tmpTable = new DataTable(); cmd.Connection.Open(); SqlCeDataReader tmpRdr = cmd.ExecuteReader(); if (tmpRdr.Read()) tmpTable.Load(tmpRdr); tmpRdr.Close(); cmd.Connection.Close(); return tmpTable; UPDATE: For the sake of trying I used the code found in one of the answers found here and it works as expected. So my code looks like this: SqlCeConnection conn = new SqlCeConnection("Data Source=" + filePath + ";Persist Security Info=False;"); DataTable tmpTable = new DataTable(); SqlCeDataAdapter AD = new SqlCeDataAdapter(Query, conn); AD.Fill(tmpTable); The issue appears to be with the SqlCeDataReader. Hope this helps someone else out!

    Read the article

  • Advice about insert into SQLCE

    - by Alexander
    i am inserting about 1943 records by these function into SQLCE.This is my insert function.Parameters come from StringReader(string comes from webservice).This function executes 1943 times and takes about 20 seconds.I dropped table's indexes,what can i do to improve it?I create just 1 time mycomm and sqlceresultset. Public Function Insert_Function(ByVal f_Line() As String, ByRef myComm As SqlCeCommand, ByRef rs As SqlCeResultSet) As String Try Dim rec As SqlCeUpdatableRecord = rs.CreateRecord() rec.SetInt32(0, IIf(f_Line(1) = "", DBNull.Value, f_Line(1))) rec.SetInt32(1, IIf(f_Line(2) = "", DBNull.Value, f_Line(2))) rec.SetInt32(2, IIf(f_Line(3) = "", DBNull.Value, f_Line(3))) rec.SetInt32(3, IIf(f_Line(4) = "", DBNull.Value, f_Line(4))) rec.SetValue(4, IIf(f_Line5(5) = "", DBNull.Value, f_Line(5))) rs.Insert(rec) rec = Nothing Catch ex As Exception strerr_col = ex.Message End Try Return strerr_col End Function

    Read the article

  • Performance in SQL Mobile with one big column that's not being selected

    - by Anthony Mastrean
    I have a SQL Mobile database with one table. It has several columns with useful, often queried data and one column that stores a relatively large string per record (1000+ characters) that is not queried often. Imagine this fake schema, the "lifeStory" field is the large one. table1 String firstName String lastName String address String lifeStory A representative query would be SELECT firstName, lastName, address FROM table1 WHERE firstName = :p1 Does anyone know of any performance concerns leaving that large, infrequently queried column in this table?

    Read the article

  • add row to a BindingSource gives different autoincrement value from whats saved into DB

    - by Ruben Trancoso
    I have a DataGridView that shows list of records and when I hit a insert button, a form should add a new record, edit its values and save it. I have a BindingSource bound to a DataGridView. I pass is as a parameter to a NEW RECORD form so // When the form opens it add a new row and de DataGridView display this new record at this time DataRowView currentRow; currentRow = (DataRowView) myBindindSource.AddNew(); when user confirm to save it I do a myBindindSource.EndEdit(); // inside the form and after the form is disposed the new row is saved and the bindingsorce position is updated to the new row DataRowView drv = myForm.CurrentRow; avaliadoTableAdapter.Update(drv.Row); avaliadoBindingSource.Position = avaliadoBindingSource.Find("ID", drv.Row.ItemArray[0]); The problem is that this table has a AUTOINCREMENT field and the value saved may not correspond the the value the bindingSource gives in EDIT TIME. So, when I close and open the DataGridView again the new rowd give its ID based on the available slot in the undelying DB at the momment is was saved and it just ignores the value the BindingSource generated ad EDIT TIME, Since the value given by the binding source should be used by another table as a foreingKey it make the reference insconsistent. There's a way to get the real ID was saved to the database?

    Read the article

  • Visual Studio error on valid SQL

    - by Sam
    I'm getting an annoying error in visual studio for SQL that executes fine. SELECT InvoiceLines.LineID, InvoiceLines.InvoiceID, InvoiceLines.Text, InvoiceLines.Rate, InvoiceLines.Count, InvoiceLines.Rate * InvoiceLines.Count AS LineTotal, ((InvoiceLines.Rate * InvoiceLines.Count) * (1 + Invoices.VatRate / 100)) * (1 - CAST(Invoices.Discount AS money) * InvoiceLines.ApplyDiscount / 100) AS LineTotalIncVat, InvoiceLines.ApplyDiscount FROM InvoiceLines LEFT JOIN Invoices ON Invoices.InvoiceID = InvoiceLines.InvoiceID What LineTotalIncVat is trying to do is compute the total for the invoice item while adding the vat and subtracting the discount, and yes, probably better to do this in code (would if I could) The error visual studio gives is: There was an error parsing the query [token line number =1, token line offset =14, token in error = InvoiceLines] Even though it will validate and execute without a problem in the query builder...

    Read the article

  • Group by/count in LINQ against SQL Compact 3.5 SP2

    - by bash74
    Hello, I am using LINQ-To-Entities in C# and run queries against a SQL Compact Server 3.5 SP2. What I try to achieve is a simple group by with an additional where clause which includes a Count(). var baseIdent="expression"; var found=from o in ObservedElements where o.ObservedRoots.BaseIdent==baseIdent group o by o.ID into grouped where grouped.Count()==1 select new {key=grouped.Key, val=grouped}; foreach(var res in found){ //do something here } This query throws the famous exception "A parameter is not allowed in this location. Ensure that the '@' sign and all other parameters are in a valid location in the SQL statement." When I either omit the where clause OR directly enter the expression "expression" in the query (where o.ObservedRoots.BaseIdent=="expression") everything just works fine. Does anybody know how to solve this? Workaround would also be fine? Thanks in advance, Sebastian

    Read the article

  • WCF hosting in .NET compact framework

    - by jauwaad
    I would like to host a service on a WinCE device. The WinCE device is the host which can be accessed(control and data acquisition) by multiple clients (PC or WinCE) over serial port, TCP, USB etc. I was considering using Protocol Buffers for serialization on the wire. It would be ideal to use WCF or remoting but as far as I see they are not implement on the Compact Framework. Anyone have any ideas how this can be achieved.

    Read the article

  • Get a "sqlceqp35.dll" error when debugging but not when running deployed code.

    - by nj
    In our current windows mobile project a problem while debugging recently arised. When trying to debug the code it throws an exception on the open command on a connection to the local database. The message is "A SQL Server Compact DLL could not be loaded. Reinstall SQL Server Compact Edition. [ DLL Name = sqlceqp35.dll ]". Sometime it's an unknow error instead, with reference to the same file. If you execute the binary, thats deployd during the debug, on the device it runs without any problem. I've tried: Reinstall both .net and sqlce on the device. Changed the "specific version" on the reference properties in the project. The hardware I'm using is a Motorola MC70 with Windows mobile 5.0. The target platform of the project is windows mobile 5.0. Any ideas on what might cause this problem? EDIT: When I tried it on a MC75 I can debug it. The MC70 got OS Version: 05.01.0478 and the MC75 05.01.0478. My best guess now is that it's someway related to the OS version or the actual device.

    Read the article

  • SQL Compact import DB from SQL Server Express with Server Management Studio

    - by Sasha
    Hi! I try to import sql script, generated with Server Management Studio, into SQL Compact 3.5 and get a lot of error. What I am doing wrong? I generate script with "Task/Generate Script" context menu. Part of my script: CREATE TABLE [LogMagazines]( [IdUser] [int] NOT NULL, [Text] [nvarchar](500) NULL, [TypeLog] [int] NOT NULL, [DateAndTime] [datetime] NOT NULL, [DetailMessage] [nvarchar](max) NULL, [Id] [int] IDENTITY(1,1) NOT NULL, CONSTRAINT [PK_LogMagazines] PRIMARY KEY ( [Id] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] Knowledge Base: http://stackoverflow.com/questions/1525063/how-to-import-data-in-sql-compact-edition http://stackoverflow.com/questions/1515969/exporting-data-in-sql-server-as-insert-into/1515975

    Read the article

  • Help me understand this C code

    - by Benjamin
    INT GetTree (HWND hWnd, HTREEITEM hItem, HKEY *pRoot, TCHAR *pszKey, INT nMax) { TV_ITEM tvi; TCHAR szName[256]; HTREEITEM hParent; HWND hwndTV = GetDlgItem (hWnd, ID_TREEV); memset (&tvi, 0, sizeof (tvi)); hParent = TreeView_GetParent (hwndTV, hItem); if (hParent) { // Get the parent of the parent of the... GetTree (hWnd, hParent, pRoot, pszKey, nMax); // Get the name of the item. tvi.mask = TVIF_TEXT; tvi.hItem = hItem; tvi.pszText = szName; tvi.cchTextMax = dim(szName); TreeView_GetItem (hwndTV, &tvi); //send the TVM_GETITEM message? lstrcat (pszKey, TEXT ("\\")); lstrcat (pszKey, szName); } else { *pszKey = TEXT ('\0'); szName[0] = TEXT ('\0'); // Get the name of the item. tvi.mask = TVIF_TEXT | TVIF_PARAM; tvi.hItem = hItem; tvi.pszText = szName; tvi.cchTextMax = dim(szName); if (TreeView_GetItem (hwndTV, &tvi)) //*pRoot = (HTREEITEM)tvi.lParam; //original hItem = (HTREEITEM)tvi.lParam; else { INT rc = GetLastError(); } } return 0; } The block of code that begins with the comment "Get the name of the item" does not make sense to me. If you are getting the listview item why does the code set the parameters of the item being retrieved? If you already had the values there would be no need to retrieve them. Secondly near the comment "original" is the original line of code which will compile with a warning under embedded visual c++ 4.0, but if you copy the exact same code into visual studio 2008 it will not compile. Since I did not write any of this code, and am trying to learn, is it possible the original author made a mistake on this line? The *pRoot should point to HKEY type yet he is casting to an HTREEITEM type which should never work since the data types don't match?

    Read the article

< Previous Page | 10 11 12 13 14 15 16 17 18 19 20 21  | Next Page >