  • Ubuntu server spontaneous reboot

    - by user1941407
    I have got two ubuntu 12.04 servers(xeon e3). Sometimes(several days) each server spontaneously reboots. HDDs and other hardware are ok. Which logfile can help find a reason of the problem? UPDATED. hardware: xeon e3 processor, intel server motherboard, 32gb ddr3 ecc, mdadm mirror hdd raid for system, mdadm ssd raid for database(postgres). Both servers have similar (not identical) components. Smart is OK. It seems that the problem is in the software. Python process and database are running on this servers. Syslog (time of reboot): Aug 23 13:42:23 xeon hddtemp[1411]: /dev/sdc: WDC WD15NPVT-00Z2TT0: 34 C Aug 23 13:42:23 xeon hddtemp[1411]: /dev/sdd: WDC WD15NPVT-00Z2TT0: 34 C Aug 23 13:43:24 xeon hddtemp[1411]: /dev/sdc: WDC WD15NPVT-00Z2TT0: 34 C Aug 23 13:43:24 xeon hddtemp[1411]: /dev/sdd: WDC WD15NPVT-00Z2TT0: 34 C Aug 23 13:44:14 xeon sensord: Chip: acpitz-virtual-0 Aug 23 13:44:14 xeon sensord: Adapter: Virtual device Aug 23 13:44:14 xeon sensord: temp1: 27.8 C Aug 23 13:44:14 xeon sensord: temp2: 29.8 C Aug 23 13:44:14 xeon sensord: Chip: coretemp-isa-0000 Aug 23 13:44:14 xeon sensord: Adapter: ISA adapter Aug 23 13:44:14 xeon sensord: Physical id 0: 37.0 C Aug 23 13:44:14 xeon sensord: Core 0: 37.0 C Aug 23 13:44:14 xeon sensord: Core 1: 37.0 C Aug 23 13:44:14 xeon sensord: Core 2: 37.0 C Aug 23 13:44:14 xeon sensord: Core 3: 37.0 C Aug 23 13:44:24 xeon hddtemp[1411]: /dev/sdc: WDC WD15NPVT-00Z2TT0: 34 C Aug 23 13:44:24 xeon hddtemp[1411]: /dev/sdd: WDC WD15NPVT-00Z2TT0: 34 C Aug 23 13:47:01 xeon kernel: imklog 5.8.6, log source = /proc/kmsg started. Aug 23 13:47:01 xeon rsyslogd: [origin software="rsyslogd" swVersion="5.8.6" x-pid="582" x-info="http://www.rsyslog.com"] start Aug 23 13:47:01 xeon rsyslogd: rsyslogd's groupid changed to 103 Aug 23 13:47:01 xeon rsyslogd: rsyslogd's userid changed to 101 Aug 23 13:47:00 xeon rsyslogd-2039: Could not open output pipe '/dev/xconsole' [try http://www.rsyslog.com/e/2039 ] Aug 23 13:47:01 xeon kernel: [ 0.000000] Initializing cgroup subsys cpuset Aug 23 13:47:01 xeon kernel: [ 0.000000] Initializing cgroup subsys cpu Aug 23 13:47:01 xeon kernel: [ 0.000000] Initializing cgroup subsys cpuacct Aug 23 13:47:01 xeon kernel: [ 0.000000] Linux version 3.11.0-26-generic (buildd@komainu) (gcc version 4.6.3 (Ubuntu/Linaro 4.6.3-1ubuntu5) ) #45~precise1-Ubuntu SMP Tue Jul 15 04:02:35 UTC 2014 (Ubuntu 3.11.0-26.45~precise1-generic 3.11.10.12) Aug 23 13:47:01 xeon kernel: [ 0.000000] Command line: BOOT_IMAGE=/boot/vmlinuz-3.11.0-26-generic root=UUID=0daa7f53-6c74-47d2-873e-ebd339cd39b0 ro splash quiet vt.handoff=7 Aug 23 13:47:01 xeon kernel: [ 0.000000] KERNEL supported cpus: Aug 23 13:47:01 xeon kernel: [ 0.000000] Intel GenuineIntel Aug 23 13:47:01 xeon kernel: [ 0.000000] AMD AuthenticAMD Aug 23 13:47:01 xeon kernel: [ 0.000000] Centaur CentaurHauls Aug 23 13:47:01 xeon kernel: [ 0.000000] e820: BIOS-provided physical RAM map: Aug 23 13:47:01 xeon kernel: [ 0.000000] BIOS-e820: [mem 0x0000000000000000-0x000000000009bbff] usable Aug 23 13:47:01 xeon kernel: [ 0.000000] BIOS-e820: [mem 0x000000000009bc00-0x000000000009ffff] reserved Dmseg - nothing strange.

    Read the article

  • Best partition Scheme for Ubuntu Server

    - by K.K Patel
    I am going to deploy Ubuntu server having Following servers on it Bind server, dhcp server, LAMP Server, Openssh Server, Ldap server, Monodb database, FTP server,mail server, Samba server, NFS server , in future I want to set Openstack for PAAS. Currently I have Raid 5 with 10TB. How should I make my Partition Scheme So never get problem in future and easily expand Storage size. Suggest me such a partition Scheme with giving specific percentage of Storage to partitions like /, /boot, /var, /etc. Thanks In advance

    Read the article

  • Can't start Psychonauts game -- segfault

    - by tremby
    This looks similar to Psychonauts Humble Indie Bundle V error but I don't have the ERROR message (missing GL capability) and its solution does not work for me. When trying to run Psychonauts from the Humble Indie Bundle on my x86_64 laptop running Ubuntu 12.04 I get the following output: <bjn@segnus:/usr/local/games/psychonauts>$ ./Psychonauts STUBBED: fix up the rest of the SSE code first at DetectSSESupport (/home/icculus/projects/psychonauts/Source/CommonLibs/DFMath/MathGeneral.cpp:32) STUBBED: write me? at SetPCLanguage (/home/icculus/projects/psychonauts/Source/game/luatest/UnixMain.cpp:120) STUBBED: fix up the rest of the SSE code first at DetectCPUCaps (/home/icculus/projects/psychonauts/Source/game/luatest/Game/PCGameApp.cpp:223) STUBBED: check LANG envr var at _GetDefaultGameLanguage (/home/icculus/projects/psychonauts/Source/game/luatest/Game/GameApp.cpp:171) Console created Save path: /home/bjn/.local/share/Psychonauts Write path: WorkResource STUBBED: inline asm at SSEMul_4x4_4x4_2arg (/home/icculus/projects/psychonauts/Source/CommonLibs/DFMath/Matrix.cpp:710) STUBBED: inline asm at SSEMul_4x4_4x4_3arg (/home/icculus/projects/psychonauts/Source/CommonLibs/DFMath/Matrix.cpp:698) ******** unit test failed ******** STUBBED: VK_* at InitInputNames (/home/icculus/projects/psychonauts/Source/CommonLibs/DirectX/SDLInput.cpp:1220) No joysticks detected Transport started DaveD: NCListenSocket: Listening on port 40001 SDL_SetVideoMode() failed: Failed loading libGL.so.1 Start Up completed in 0.06 seconds [1] 9718 segmentation fault (core dumped) ./Psychonauts <bjn@segnus:/usr/local/games/psychonauts>$ Output of lspci: 00:00.0 Host bridge: Intel Corporation Mobile 4 Series Chipset Memory Controller Hub (rev 07) 00:02.0 VGA compatible controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:02.1 Display controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:19.0 Ethernet controller: Intel Corporation 82567LM Gigabit Network Connection (rev 03) 00:1a.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #4 (rev 03) 00:1a.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #5 (rev 03) 00:1a.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #6 (rev 03) 00:1a.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #2 (rev 03) 00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) 00:1c.0 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 1 (rev 03) 00:1c.1 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 2 (rev 03) 00:1c.3 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 4 (rev 03) 00:1d.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #1 (rev 03) 00:1d.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #2 (rev 03) 00:1d.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #3 (rev 03) 00:1d.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #1 (rev 03) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev 93) 00:1f.0 ISA bridge: Intel Corporation ICH9M-E LPC Interface Controller (rev 03) 00:1f.2 RAID bus controller: Intel Corporation 82801 Mobile SATA Controller [RAID mode] (rev 03) 00:1f.3 SMBus: Intel Corporation 82801I (ICH9 Family) SMBus Controller (rev 03) 02:01.0 FireWire (IEEE 1394): Ricoh Co Ltd R5C832 IEEE 1394 Controller (rev 05) 02:01.1 SD Host controller: Ricoh Co Ltd R5C822 SD/SDIO/MMC/MS/MSPro Host Adapter (rev 22) 0c:00.0 Network controller: Intel Corporation WiFi Link 5100 Any ideas?

    Read the article

  • Reference Data Management and Master Data: Are Relation ?

    - by Mala Narasimharajan
    Submitted By:  Rahul Kamath  Oracle Data Relationship Management (DRM) has always been extremely powerful as an Enterprise Master Data Management (MDM) solution that can help manage changes to master data in a way that influences enterprise structure, whether it be mastering chart of accounts to enable financial transformation, or revamping organization structures to drive business transformation and operational efficiencies, or restructuring sales territories to enable equitable distribution of leads to sales teams following the acquisition of new products, or adding additional cost centers to enable fine grain control over expenses. Increasingly, DRM is also being utilized by Oracle customers for reference data management, an emerging solution space that deserves some explanation. What is reference data? How does it relate to Master Data? Reference data is a close cousin of master data. While master data is challenged with problems of unique identification, may be more rapidly changing, requires consensus building across stakeholders and lends structure to business transactions, reference data is simpler, more slowly changing, but has semantic content that is used to categorize or group other information assets – including master data – and gives them contextual value. In fact, the creation of a new master data element may require new reference data to be created. For example, when a European company acquires a US business, chances are that they will now need to adapt their product line taxonomy to include a new category to describe the newly acquired US product line. Further, the cross-border transaction will also result in a revised geo hierarchy. The addition of new products represents changes to master data while changes to product categories and geo hierarchy are examples of reference data changes.1 The following table contains an illustrative list of examples of reference data by type. Reference data types may include types and codes, business taxonomies, complex relationships & cross-domain mappings or standards. Types & Codes Taxonomies Relationships / Mappings Standards Transaction Codes Industry Classification Categories and Codes, e.g., North America Industry Classification System (NAICS) Product / Segment; Product / Geo Calendars (e.g., Gregorian, Fiscal, Manufacturing, Retail, ISO8601) Lookup Tables (e.g., Gender, Marital Status, etc.) Product Categories City à State à Postal Codes Currency Codes (e.g., ISO) Status Codes Sales Territories (e.g., Geo, Industry Verticals, Named Accounts, Federal/State/Local/Defense) Customer / Market Segment; Business Unit / Channel Country Codes (e.g., ISO 3166, UN) Role Codes Market Segments Country Codes / Currency Codes / Financial Accounts Date/Time, Time Zones (e.g., ISO 8601) Domain Values Universal Standard Products and Services Classification (UNSPSC), eCl@ss International Classification of Diseases (ICD) e.g., ICD9 à IC10 mappings Tax Rates Why manage reference data? Reference data carries contextual value and meaning and therefore its use can drive business logic that helps execute a business process, create a desired application behavior or provide meaningful segmentation to analyze transaction data. Further, mapping reference data often requires human judgment. Sample Use Cases of Reference Data Management Healthcare: Diagnostic Codes The reference data challenges in the healthcare industry offer a case in point. Part of being HIPAA compliant requires medical practitioners to transition diagnosis codes from ICD-9 to ICD-10, a medical coding scheme used to classify diseases, signs and symptoms, causes, etc. The transition to ICD-10 has a significant impact on business processes, procedures, contracts, and IT systems. Since both code sets ICD-9 and ICD-10 offer diagnosis codes of very different levels of granularity, human judgment is required to map ICD-9 codes to ICD-10. The process requires collaboration and consensus building among stakeholders much in the same way as does master data management. Moreover, to build reports to understand utilization, frequency and quality of diagnoses, medical practitioners may need to “cross-walk” mappings -- either forward to ICD-10 or backwards to ICD-9 depending upon the reporting time horizon. Spend Management: Product, Service & Supplier Codes Similarly, as an enterprise looks to rationalize suppliers and leverage their spend, conforming supplier codes, as well as product and service codes requires supporting multiple classification schemes that may include industry standards (e.g., UNSPSC, eCl@ss) or enterprise taxonomies. Aberdeen Group estimates that 90% of companies rely on spreadsheets and manual reviews to aggregate, classify and analyze spend data, and that data management activities account for 12-15% of the sourcing cycle and consume 30-50% of a commodity manager’s time. Creating a common map across the extended enterprise to rationalize codes across procurement, accounts payable, general ledger, credit card, procurement card (P-card) as well as ACH and bank systems can cut sourcing costs, improve compliance, lower inventory stock, and free up talent to focus on value added tasks. Change Management: Point of Sales Transaction Codes and Product Codes In the specialty finance industry, enterprises are confronted with usury laws – governed at the state and local level – that regulate financial product innovation as it relates to consumer loans, check cashing and pawn lending. To comply, it is important to demonstrate that transactions booked at the point of sale are posted against valid product codes that were on offer at the time of booking the sale. Since new products are being released at a steady stream, it is important to ensure timely and accurate mapping of point-of-sale transaction codes with the appropriate product and GL codes to comply with the changing regulations. Multi-National Companies: Industry Classification Schemes As companies grow and expand across geographies, a typical challenge they encounter with reference data represents reconciling various versions of industry classification schemes in use across nations. While the United States, Mexico and Canada conform to the North American Industry Classification System (NAICS) standard, European Union countries choose different variants of the NACE industry classification scheme. Multi-national companies must manage the individual national NACE schemes and reconcile the differences across countries. Enterprises must invest in a reference data change management application to address the challenge of distributing reference data changes to downstream applications and assess which applications were impacted by a given change. References 1 Master Data versus Reference Data, Malcolm Chisholm, April 1, 2006.

    Read the article

  • Why does Unity screen blank out over XDMCP?

    - by James
    My XDMCP sessions display fine until I login. I've checked all logs and settings for this and can't find anything wrong, this works fine on other systems so I'm wondering if this has anything to do with the underlying hardware or an application that loads when logging in. System details: - Ubuntu 12.04 (Desktop, installed via Alternate CD for RAID) - 8GB of RAM - Core2Quad CPU @ 2.40GHz - Gigabit Network (Ethernet) Other notes: - Running with the onscreen keyboard enabled - Works fine when logging in locally Pre-login: Once logged in:

    Read the article

  • Impossible to install Ubuntu 10.10 dual boot with Windows 7 on new Acer desktop computer

    - by Don Myers
    My brother has a brand new Acer Desktop with Windows 7. I have done many installs (40+) of Ubuntu starting with 8.10, and have never run into this. I've spent three hours trying to do a dual boot install of 10.10. When you get to the place where you normally would choose to install as a dual boot or overwrite the existing information on the hard drive, that block is just blank. Nothing. No choices even to do a manual partition setup. If you try to go on you get the message "No root file system is defined. Please correct this from the partitioning menu." but there is nothing in the partitioning menu. I tried a good 10.04 disc also. Same thing happens with it. I ran a gparted live cd, and it shows the hard drive as sda with 3 partitions on the original. sda1 is a small partition called PQService. sda2 is another small partition called System Reserved, and GParted says it is the boot partition. sda3 is the main partation with the operating system (Windows 7) and all of the empty space. There is a little unallocated space at the very beginning and very end of the hard drive. If I go to places in the Live CD, it shows a 640 gb hard disk called Acer, but it also shows a 640 gb hard disk called system reserved. They are the same disk. There is just one hard drive. If you click properties in the System Reserved 640 gb, it shows all information as unknown. I had to change the boot order in the bios in order to run the live cd. The hard drive instead of being listed as such is listed as Raid:Raid Ready. Something the way this computer is set up is preventing Ubuntu from being able to identify the hard drive partitions at all to do an install, even if you were not doing a dual boot and just wanted to overwrite Windows. Is this a bug that needs reported? This is a major problem for me and my brother, but also for Ubuntu if new users want to Ubuntu and find they cannot install it.

    Read the article

  • System won't boot unless I type "exit" at initramfs prompt

    - by Ozzah
    I installed MDADM for my RAID, and ever since that when I boot up the system just sits at the purple screen forever. After pulling my hair out for a week, I finally discovered - purely by accident - that it's sitting at an initramfs prompt in the background and I have to blindly type "exit" and then Ubuntu resumes normal boot. How do I fix this? I am unable to reboot my machine if I'm not sitting in front of it because it will never boot!

    Read the article

  • OpenGL 3 and the Radeon HD 4850x2

    - by rotard
    A while ago, I picked up a copy of the OpenGL SuperBible fifth edition and slowly and painfully started teaching myself OpenGL the 3.3 way, after having been used to the 1.0 way from school way back when. Making things more challenging, I am primarily a .NET developer, so I was working in Mono with the OpenTK OpenGL wrapper. On my laptop, I put together a program that let the user walk around a simple landscape using a couple shaders that implemented per-vertex coloring and lighting and texture mapping. Everything was working brilliantly until I ran the same program on my desktop. Disaster! Nothing would render! I have chopped my program down to the point where the camera sits near the origin, pointing at the origin, and renders a square (technically, a triangle fan). The quad renders perfectly on my laptop, coloring, lighting, texturing and all, but the desktop renders a small distorted non-square quadrilateral that is colored incorrectly, not affected by the lights, and not textured. I suspect the graphics card is at fault, because I get the same result whether I am booted into Ubuntu 10.10 or Win XP. I did find that if I pare the vertex shader down to ONLY outputting the positional data and the fragment shader to ONLY outputting a solid color (white) the quad renders correctly. But as SOON as I start passing in color data (whether or not I use it in the fragment shader) the output from the vertex shader is distorted again. The shaders follow. I left the pre-existing code in, but commented out so you can get an idea what I was trying to do. I'm a noob at glsl so the code could probably be a lot better. My laptop is an old lenovo T61p with a Centrino (Core 2) Duo and an nVidia Quadro graphics card running Ubuntu 10.10 My desktop has an i7 with a Radeon HD 4850 x2 (single card, dual GPU) from Saphire dual booting into Ubuntu 10.10 and Windows XP. The problem occurs in both XP and Ubuntu. Can anyone see something wrong that I am missing? What is "special" about my HD 4850x2? string vertexShaderSource = @" #version 330 precision highp float; uniform mat4 projection_matrix; uniform mat4 modelview_matrix; //uniform mat4 normal_matrix; //uniform mat4 cmv_matrix; //Camera modelview. Light sources are transformed by this matrix. //uniform vec3 ambient_color; //uniform vec3 diffuse_color; //uniform vec3 diffuse_direction; in vec4 in_position; in vec4 in_color; //in vec3 in_normal; //in vec3 in_tex_coords; out vec4 varyingColor; //out vec3 varyingTexCoords; void main(void) { //Get surface normal in eye coordinates //vec4 vEyeNormal = normal_matrix * vec4(in_normal, 0); //Get vertex position in eye coordinates //vec4 vPosition4 = modelview_matrix * vec4(in_position, 0); //vec3 vPosition3 = vPosition4.xyz / vPosition4.w; //Get vector to light source in eye coordinates //vec3 lightVecNormalized = normalize(diffuse_direction); //vec3 vLightDir = normalize((cmv_matrix * vec4(lightVecNormalized, 0)).xyz); //Dot product gives us diffuse intensity //float diff = max(0.0, dot(vEyeNormal.xyz, vLightDir.xyz)); //Multiply intensity by diffuse color, force alpha to 1.0 //varyingColor.xyz = in_color * diff * diffuse_color.xyz; varyingColor = in_color; //varyingTexCoords = in_tex_coords; gl_Position = projection_matrix * modelview_matrix * in_position; }"; string fragmentShaderSource = @" #version 330 //#extension GL_EXT_gpu_shader4 : enable precision highp float; //uniform sampler2DArray colorMap; //in vec4 varyingColor; //in vec3 varyingTexCoords; out vec4 out_frag_color; void main(void) { out_frag_color = vec4(1,1,1,1); //out_frag_color = varyingColor; //out_frag_color = vec4(varyingColor, 1) * texture(colorMap, varyingTexCoords.st); //out_frag_color = vec4(varyingColor, 1) * texture(colorMap, vec3(varyingTexCoords.st, 0)); //out_frag_color = vec4(varyingColor, 1) * texture2DArray(colorMap, varyingTexCoords); }"; Note that in this code the color data is accepted but not actually used. The geometry is outputted the same (wrong) whether the fragment shader uses varyingColor or not. Only if I comment out the line varyingColor = in_color; does the geometry output correctly. Originally the shaders took in vec3 inputs, I only modified them to take vec4s while troubleshooting.

    Read the article

  • 1000baseT/Full Supported and Advertised but not working!

    - by user11973
    Hello, i'm using a AT3IONT-I motherboard with integrated card. If I ethtool it to 1000 full duplex it wont work! Here is sudo ethtool eth0: Supported ports: [ TP ] Supported link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Full Supports auto-negotiation: Yes Advertised link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Full Advertised pause frame use: Symmetric Receive-only Advertised auto-negotiation: Yes Speed: 100Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: internal Auto-negotiation: on MDI-X: Unknown Supports Wake-on: pumbg Wake-on: g Current message level: 0x00000033 (51) Link detected: yes here is sudo lshw -C network: *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:04:00.0 logical name: eth0 version: 03 serial: bc:ae:c5:8b:7d:33 size: 100MB/s capacity: 1GB/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8168 driverversion=8.021.00-NAPI duplex=full ip=192.168.0.2 latency=0 link=yes multicast=yes port=twisted pair speed=100MB/s resources: irq:42 ioport:e800(size=256) memory:f8fff000-f8ffffff memory:f8ff8000-f8ffbfff memory:fbff0000-fbffffff And lspci -nn: 00:00.0 Host bridge [0600]: nVidia Corporation MCP79 Host Bridge [10de:0a82] (rev b1) 00:00.1 RAM memory [0500]: nVidia Corporation MCP79 Memory Controller [10de:0a88] (rev b1) 00:03.0 ISA bridge [0601]: nVidia Corporation MCP79 LPC Bridge [10de:0aad] (rev b3) 00:03.1 RAM memory [0500]: nVidia Corporation MCP79 Memory Controller [10de:0aa4] (rev b1) 00:03.2 SMBus [0c05]: nVidia Corporation MCP79 SMBus [10de:0aa2] (rev b1) 00:03.3 RAM memory [0500]: nVidia Corporation MCP79 Memory Controller [10de:0a89] (rev b1) 00:03.5 Co-processor [0b40]: nVidia Corporation MCP79 Co-processor [10de:0aa3] (rev b1) 00:04.0 USB Controller [0c03]: nVidia Corporation MCP79 OHCI USB 1.1 Controller [10de:0aa5] (rev b1) 00:04.1 USB Controller [0c03]: nVidia Corporation MCP79 EHCI USB 2.0 Controller [10de:0aa6] (rev b1) 00:06.0 USB Controller [0c03]: nVidia Corporation MCP79 OHCI USB 1.1 Controller [10de:0aa7] (rev b1) 00:06.1 USB Controller [0c03]: nVidia Corporation MCP79 EHCI USB 2.0 Controller [10de:0aa9] (rev b1) 00:08.0 Audio device [0403]: nVidia Corporation MCP79 High Definition Audio [10de:0ac0] (rev b1) 00:09.0 PCI bridge [0604]: nVidia Corporation MCP79 PCI Bridge [10de:0aab] (rev b1) 00:0b.0 RAID bus controller [0104]: nVidia Corporation MCP79 RAID Controller [10de:0abc] (rev b1) 00:0c.0 PCI bridge [0604]: nVidia Corporation MCP79 PCI Express Bridge [10de:0ac4] (rev b1) 00:10.0 PCI bridge [0604]: nVidia Corporation MCP79 PCI Express Bridge [10de:0aa0] (rev b1) 00:15.0 PCI bridge [0604]: nVidia Corporation MCP79 PCI Express Bridge [10de:0ac6] (rev b1) 03:00.0 VGA compatible controller [0300]: nVidia Corporation ION VGA [10de:087d] (rev b1) 04:00.0 Ethernet controller [0200]: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller [10ec:8168] (rev 03) If i use Code: sudo ethtool -s eth0 speed 1000 duplex full autoneg off then in ethtool speed is Unknown and it doesn't work; if I set it via pre-up it wont work either... Please help!! Thanks!

    Read the article

  • Leeroy Jenkins Reimagined As a Bank Heist [Video]

    - by Jason Fitzpatrick
    In this 3-minute short film, Leeroy Jenkins of World of War Craft infamy, brings his raid-botching power to the real world in a bank heist gone wrong. If you haven’t seen the original Leeroy Jenkins clip, watch it first to properly contextualize this entertaining little film. [via Super Punch] HTG Explains: Learn How Websites Are Tracking You Online Here’s How to Download Windows 8 Release Preview Right Now HTG Explains: Why Linux Doesn’t Need Defragmenting

    Read the article

  • Why won't USB 3.0 external hard drive run at USB 3.0 speeds?

    - by jgottula
    I recently purchased a PCI Express x1 USB 3.0 controller card (containing the NEC USB 3.0 controller) with the intent of using a USB 3.0 external hard drive with my Linux box. I installed the card in an empty PCIe slot on my motherboard, connected the card to a power cable, strung a USB 3.0 cable between one of the new ports and my external HDD, and connected the HDD to a wall socket for power. Booting the system, the drive works 100% as intended, with the one exception of throughput: rather than using SuperSpeed 4.8 Gbps connectivity, it seems to be falling back to High Speed 480 Mbps USB 2.0-style throughput. Disk Utility shows it as a 480 Mbps device, and running a couple Disk Utility and dd benchmarks confirms that the drive fails to exceed ~40 MB/s (the approximate limit of USB 2.0), despite it being an SSD capable of far more than that. When I connect my USB 3.0 HDD, dmesg shows this: [ 3923.280018] usb 3-2: new high speed USB device using ehci_hcd and address 6 where I would expect to find this: [ 3923.280018] usb 3-2: new SuperSpeed USB device using xhci_hcd and address 6 My system was running on kernel 2.6.35-25-generic at the time. Then, I stumbled upon this forum thread by an individual who found that a bug, which was present in kernels prior to 2.6.37-rc5, could be the culprit for this type of problem. Consequently, I installed the 2.6.37-generic mainline Ubuntu kernel to determine if the problem would go away. It didn't, so I tried 2.6.38-rc3-generic, and even the 2.6.38 nightly from 2010.02.01, to no avail. In short, I'm trying to determine why, with USB 3.0 support in the kernel, my USB 3.0 drive fails to run at full SuperSpeed throughput. See the comments under this question for additional details. Output that might be relevant to the problem (when booting from 2.6.38-rc3): Relevant lines from dmesg: [ 19.589491] xhci_hcd 0000:03:00.0: PCI INT A -> GSI 17 (level, low) -> IRQ 17 [ 19.589512] xhci_hcd 0000:03:00.0: setting latency timer to 64 [ 19.589516] xhci_hcd 0000:03:00.0: xHCI Host Controller [ 19.589623] xhci_hcd 0000:03:00.0: new USB bus registered, assigned bus number 12 [ 19.650492] xhci_hcd 0000:03:00.0: irq 17, io mem 0xf8100000 [ 19.650556] xhci_hcd 0000:03:00.0: irq 47 for MSI/MSI-X [ 19.650560] xhci_hcd 0000:03:00.0: irq 48 for MSI/MSI-X [ 19.650563] xhci_hcd 0000:03:00.0: irq 49 for MSI/MSI-X [ 19.653946] xHCI xhci_add_endpoint called for root hub [ 19.653948] xHCI xhci_check_bandwidth called for root hub Relevant section of sudo lspci -v: 03:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 03) (prog-if 30) Flags: bus master, fast devsel, latency 0, IRQ 17 Memory at f8100000 (64-bit, non-prefetchable) [size=8K] Capabilities: [50] Power Management version 3 Capabilities: [70] MSI: Enable- Count=1/8 Maskable- 64bit+ Capabilities: [90] MSI-X: Enable+ Count=8 Masked- Capabilities: [a0] Express Endpoint, MSI 00 Capabilities: [100] Advanced Error Reporting Capabilities: [140] Device Serial Number ff-ff-ff-ff-ff-ff-ff-ff Capabilities: [150] #18 Kernel driver in use: xhci_hcd Kernel modules: xhci-hcd Relevant section of sudo lsusb -v: Bus 012 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 3.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 3 bMaxPacketSize0 9 idVendor 0x1d6b Linux Foundation idProduct 0x0003 3.0 root hub bcdDevice 2.06 iManufacturer 3 Linux 2.6.38-020638rc3-generic xhci_hcd iProduct 2 xHCI Host Controller iSerial 1 0000:03:00.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 4 wHubCharacteristic 0x0009 Per-port power switching Per-port overcurrent protection TT think time 8 FS bits bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0100 power Device Status: 0x0003 Self Powered Remote Wakeup Enabled Full, non-verbose lsusb: Bus 012 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 011 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 010 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 009 Device 003: ID 04d9:0702 Holtek Semiconductor, Inc. Bus 009 Device 002: ID 046d:c068 Logitech, Inc. G500 Laser Mouse Bus 009 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 008 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 007 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 006: ID 174c:5106 ASMedia Technology Inc. Bus 003 Device 004: ID 0bda:0151 Realtek Semiconductor Corp. Mass Storage Device (Multicard Reader) Bus 003 Device 002: ID 058f:6366 Alcor Micro Corp. Multi Flash Reader Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 006: ID 1687:0163 Kingmax Digital Inc. Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 001 Device 002: ID 046d:081b Logitech, Inc. Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Full output: full dmesg full lspci full lsusb

    Read the article

  • Avoid random disk names

    - by BarsMonster
    Hi! I have Ubuntu Server 10.04 1 system disk, and 5 disks in RAID-5 configuration. The problem is that names of these disks are changed from time to time, they are being randomly mixed from time to time (sda,b,c,d,e,f - so system disks might be sda, or sdc at different time for example).... is there any way to fix drive names, so that even if it's disconnected for example, no other drive can occupy this letter based on disk UUID or something?

    Read the article

  • 11g R2 RAC Expert ????????? ~?????????~

    - by user763243
    ??????????????????????????????????????????????????????????????????????··· ??1??????????HDD????????????????????????????????????????????????HDD?????????????????????5?????DVD???????????????(???????????????????? ?)?????????????? IT????????????????????RAID????????????????????????????????????????HDD?????????????????????????????????????????????????????????????HDD???????????????????6????1?8?????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????···orz ???RAC?????????????????????????·?????????????????????????????????????????????iPhone????????????????????WiFi??????????????????????????????????????????????????????????????????????? ??????????????????????????????????3G??????????????????????????????????????????????????????? ???????????????????????????????????????????PDF??????????????????????????????????????????????????????????????????????????????(????????????)???????????????????????????????????????????????????PDF?????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????? ???????????????????????????iPhone???????????????????????????????????????????????????????????????????????? ??????????????????????????????????????????????????????????????????????????????????????????????????(??)????????????????????

    Read the article

  • Dell VRTX - slow cluster shared storage

    - by NorbyTheGeek
    I have a brand new Dell VRTX box set up as a Failover Cluster running HA Hyper-V virtual machines. This is my first time setting up clustering, and my first time with one of these boxes, so I'm sure I've missed something. The virtual machines are experiencing high disk latency and bad performance when accessing their VHD(x) files located on a Cluster Shared Volume. The VRTX has 10 x 900 GB 10K SAS drives in RAID 6 configuration, and the VRTX has the redundant Shared PERC 8 controllers. Both blades have full access to the virtual disks. There are two M520 blades installed, each with 128 GB RAM. MPIO is configured for the PERC 8 controllers. Operating system on the blades is Server 2012 (NOT R2). The RAID 6 array is split into a small (8 GB) volume for cluster quorum witness and a large (6.5 TB) volume for a Cluster Shared Volume (mounted on the nodes as C:\ClusterStorage\Volume1) An example of slow disk access: logging into a Server 2012 VM and having Server Manager come up automatically. Disk access goes to 100%, with write speeds at 20 MB or so, read speeds of 500 KB or so, and Average Response Time of over 1000 ms, sometimes spiking at 4000-5000 ms or so. It's the latency that really worries me. Is there something specific I should look at in my configuration? It doesn't seem to matter whether I use VHD or VHDX, dynamic or static.

    Read the article

  • Dell 2950 Perc 6/i "physical disk" and "Enclosure(Backplane)" under Connector 1 in OMSA tree- Troubleshoot help

    - by user66357
    Just looking for someone who might know why this could occur... In OMSA, on my Dell 2950, there usually is only one "Physical Disks" child under "Enclosure (Backplane)" in the tree view. Currently, the tree looks like this: Dell PERC 6/i Integrated Connector 1 (RAID) Enclosure (Backplane) Physical Disks (1:04 good, 1:05 removed) Physical Disks (1:33 Ready but unused) Normally it's like this: Connector 1 (RAID) Enclosure (Backplane) Physical Disks (1:04 good, 1:05 good) From the front, 6 of 6 3.5" SAS drives are connected. The server is showing Slot 5 as bad and the disk as removed. It seems that the drive in Slot 5 is being sensed as external to the Enclosure. Any ideas why this would happen? Think I can get away with rebuilding the virtual disk by replacing 1:05 with 1:33? Thanks. UPDATE: The only options on the Physical Disk 1:33 were Assign as Global Hot Spare and Clear... After clearing, I assigned it as the Global Hot Spare. This allowed the rebuilding of the virtual disk. Hopefully it won't fail. I'm still unsure of the reason for this odd behavior. I'm checking the firmware next.

    Read the article

  • Dell Perc 6i with FreeBSD 8.1 errors with mfi0: COMMAND xxxxxxxx TIMEOUT AFTER xxx SECONDS

    - by jDempster
    We've recently bought two Dell PowerEdge R710 servers with Perc 6i controllers and 6x 135GB SAS Drives. We'd done some pretty extensive testing on a Dell PowerEdge R510 server with a Perc 6i and 4x 135GB SAS Drives running FreeBSD 8.1 for it's wonderful ZFS support and mfiutil. We hadn't had any problems with the R510 and had got to a point where we where happy with the performance of ZFS. Since running FreeBSD 8.1 on the R710 we've been getting errors from the RAID controller. mfi0: COMMAND 0xffffff80005d1770 TIMEOUT AFTER 6178 SECONDS This usually brings the system to a stand still. But it doesn't always happen, and performs very well up until it does happen. We've been running the disk as 3 mirrored drives striped in ZFS. So far we've noticed that running the drives with RAID10 on the RAID seems to work without errors (still testing). At first I thought hardware error as we'd been running FreeBSD on the R510 with the same controller without any issues. But both R710 have the same issue. All controllers are running the same firmware.

    Read the article

  • VMWare ESX, storage over 2TB

    - by Phliplip
    Hi, First of, i'm a webdeveloper and my server experience lies in setting up FreeBSD servers for webserver. I'm working on a project for at photographer, and i'm hired to develop a new online photo ordering system - where user of course can view their photos :) They have a massive need of storage, thus we have bought a HP G6 and 8x1TB SATA HDD. Our plan is to install VMWare ESX 4.0, running multiple virtual machines; FreeBSD 8 for webserver and some windows servers. Allready done that. Then mount one big storage to the BSD, and share it through Samba to the WinServers. The raid is set up with an array of 2x 1TB to handle the VMs. And the rest is setup as 3 2x1TB to handle the photo-data. Thus 2.73TB for photo-data (the raids are 1+0). Now if we add a datastore in the ESX and add the 3 LUNs we can get a datastore of 2.74TB. But i don't se how i can add this datastore direct to the VM. Only the BSD VM needs access to this. Only way is to create a VirtualDisk, with a max of 2TB (8MB blocksize). This is because the datastore where we save the virtualdisk has a maximum filesize of 2TB. Then add it as a harddisk to the BSD VM. In the 'Add Harddisk' pane for the VM, i see an option for Raw Disk Management. I think this is to access the datastore or the raid directly. Only problem is that its greyed out! Can i access the datastorage directly from the BSD? Without creating and adding virtualdisk.

    Read the article

  • RAID1 Broken Mirroring

    - by Sanoj
    I'm having a little server with Windows Small Business Server 2003. I'm using RAID1, via a HighPoint Rocket RAID 1640 RAID-card, using two harddrives. This week the server alarmed, and durig reboot I got the error-message Broken Mirroring (User Manual page 30). I had a few alternatives (see the manual), first I tried Continue, but the server restarted during boot. Next time I took Power Off, and replaced the oldest harddrive with a new one, and when I booted, I selected Rebuild. Then I selected the new harddrive to be the new one. The rebuild-procedure started and a progress bar at 0% showed up, but after a few seconds I got the message Copy Failed!, then the server booted and Windows Server started. Now it works fine. But I guess that I'm just using one harddrive now, and it's not mirrored. I haven't touched the server since then (two days ago). What should I do now? I have no experience of this situation. Anyone that have some guidance?

    Read the article

  • Bad Blocks Exist in Virtual Device PERC H700 Integrated

    - by neoX
    I have a DELL server with PERC H700 Integrated controller. I've made RAID5 with 12 harddrives and the virtual device is in Optimal state, but I receive such errors under linux: sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bd 98 00 00 00 08 00 00 end_request: I/O error, dev sda, sector 30640487832 sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bd 98 00 00 00 08 00 00 end_request: I/O error, dev sda, sector 30640487832 sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bc e0 00 00 01 00 00 00 end_request: I/O error, dev sda, sector 30640487648 But all disk are in Firmware state: Online, Spun Up. Also there is not a single ATA read or write error in any disk in the raid (I check them with smartctl -a -d sat+megaraid,N -H /dev/sda). The only strange thing is in the output in megacli: megacli -LDInfo -L0 -a0 ... Bad Blocks Exist: Yes How could there be bad blocks in a Virtual Drive, which is in optimal state and no disk is broken or even with a single error? I tried "Consistency Check", but it finished successfully and the errors are still in dmesg. Could Someone help me to figure it out what is wrong with my raid?

    Read the article

  • Hardware for a home server running Windows Server 2008 R2 Hyper-V or Microsoft Hyper-V Server 2008 R2

    - by David Hayes
    Hi, I'm planning to build a server to do the following Act as a file server (videos, pictures music) Run Squeezebox server Run Zune Software to allow wireless syncing to Windows Phone 7 I'd also like to aim for Low power usage (i'd settle for less than the 90-100Watts I'm using atm Flexibility, I might want to add a web server or sharepoint or... Something I can learn/test on, work is mainly a Windows shop but I do have Linux experience too I'd like to take a look at App-V (application virtualization) too I'd like it to cost less than $1000 Quiet would be nice but not essential (it'll be in the basement) I'm thinking of getting a technet subscription to get access to Windows Server 2008 R2 at a reasonable price ($199) So my plan was this Get a bunch of 2TB Caviar green drives to RAID up (RAID 1 or 6 probably) Get a Quad core CPU (Intel i5/i7 probably) Install a Hypervisor Install w2k8 R2 Storage Server for a NAS Install Windows 7 Pro to run Zune/Squeeze box Install any other machines I want to play with Questions Can anyone see any issues with this or have any better ideas? Do you think I'd need an i7 over an i5? Is 4 cores enough/too much? Can anyone sugest a nice, reasonably priced case that will hold 6-8 drives and stay cool Should I wait for Sandy Bridge parts?

    Read the article

  • Is it possible to shrink the size of an HP Smart Array logical drive?

    - by ewwhite
    I know extension is quite possible using the hpacucli utility, but is there an easy way to reduce the size of an existing logical drive (not array)? The controller is a P410i in a ProLiant DL360 G6 server. I'd like to reduce logicaldrive 1 from 72GB to 40GB. => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G

    Read the article

  • Resizing a LUKS encrypted volume

    - by mgorven
    I have a 500GiB ext4 filesystem on top of LUKS on top of an LVM LV. I want to resize the LV to 100GiB. I know how to resize ext4 on top of an LVM LV, but how do I deal with the LUKS volume? mgorven@moab:~% sudo lvdisplay /dev/moab/backup --- Logical volume --- LV Name /dev/moab/backup VG Name moab LV UUID nQ3z1J-Pemd-uTEB-fazN-yEux-nOxP-QQair5 LV Write Access read/write LV Status available # open 1 LV Size 500.00 GiB Current LE 128000 Segments 1 Allocation inherit Read ahead sectors auto - currently set to 2048 Block device 252:3 mgorven@moab:~% sudo cryptsetup status backup /dev/mapper/backup is active and is in use. type: LUKS1 cipher: aes-cbc-essiv:sha256 keysize: 256 bits device: /dev/mapper/moab-backup offset: 3072 sectors size: 1048572928 sectors mode: read/write mgorven@moab:~% sudo tune2fs -l /dev/mapper/backup tune2fs 1.42 (29-Nov-2011) Filesystem volume name: backup Last mounted on: /srv/backup Filesystem UUID: 63877e0e-0549-4c73-8535-b7a81eb363ed Filesystem magic number: 0xEF53 Filesystem revision #: 1 (dynamic) Filesystem features: has_journal ext_attr resize_inode dir_index filetype extent flex_bg sparse_super large_file huge_file uninit_bg dir_nlink extra_isize Filesystem flags: signed_directory_hash Default mount options: (none) Filesystem state: clean with errors Errors behavior: Continue Filesystem OS type: Linux Inode count: 32768000 Block count: 131071616 Reserved block count: 0 Free blocks: 112894078 Free inodes: 32044830 First block: 0 Block size: 4096 Fragment size: 4096 Reserved GDT blocks: 992 Blocks per group: 32768 Fragments per group: 32768 Inodes per group: 8192 Inode blocks per group: 512 RAID stride: 128 RAID stripe width: 128 Flex block group size: 16 Filesystem created: Sun Mar 11 19:24:53 2012 Last mount time: Sat May 19 13:29:27 2012 Last write time: Fri Jun 1 11:07:22 2012 Mount count: 0 Maximum mount count: 100 Last checked: Fri Jun 1 11:03:50 2012 Check interval: 31104000 (12 months) Next check after: Mon May 27 11:03:50 2013 Lifetime writes: 118 GB Reserved blocks uid: 0 (user root) Reserved blocks gid: 0 (group root) First inode: 11 Inode size: 256 Required extra isize: 28 Desired extra isize: 28 Journal inode: 8 Default directory hash: half_md4 Directory Hash Seed: 383bcbc5-fde9-4720-b98e-2d6224713ecf Journal backup: inode blocks

    Read the article

  • Configuration for a two machine ESXi cluster using VSA to present local storage to VMs

    - by MDMarra
    I'm designing a little vSphere 5 cluster for one of our remote sites. We have some IBM x3650s that have 6x 300GB 10K RPM drives in them, along with dual quad core CPUs and 24GB RAM. Because we use HP P4500 G2s at our primary site, we have licenses available for HP P4000 VSAs. I thought that this would be the perfect opportunity to use them. Below is a basic drawing of what I want to accomplish: I want to run a P4000 VSA on each server and run them in a Network RAID-10 (Lefthand speak for network mirroring, think of it as RAID 1 across nodes or as an active/active storage cluster). I will then present this storage to guests that will run on this mini-cluster. It will be managed by a vCenter Server on our main site. All connections will be GbE with two dedicated to storage. Management and Data will share a pair of connections, since I don't expect there to be high load. These servers are just there to provide directory services, dhcp, printing, etc. Does anyone see anything potentially wrong with this approach? Is this the best way to do this without adding additional dedicated storage heads? Are there any pitfalls in this design, besides the lack of dedicated Data/Mgmt interfaces?

    Read the article