Search Results

Search found 8465 results on 339 pages for '40 love'.

Page 145/339 | < Previous Page | 141 142 143 144 145 146 147 148 149 150 151 152  | Next Page >

  • Rack layout for future growth

    - by bleything
    We're getting ready to move to a new colo facility and I'm designing the rack layout. While we have a full rack, we only have 12U worth of hardware right now: 1x 1U switch 7x 1U servers 1x 2U server 1x 2U disk shelf The colo facility requires us to front-mount the switch and use a 1U brush strip, so we'll be using a total of 13U of space. Regarding growth, I'm reasonably sure we'll be adding another 4U in servers, 1-2U of network gear, and 2-4U of storage in the mid-term. Specific questions I'm hoping to get help with: where should I mount the switch? the LEDs are on top... should I group the servers by function with space for adding new machines? as an alternative, should I group servers based on whether they are production or staging? where in the rack should I start? in the middle? at the top? at the bottom? equally spaced? Here's a silly little ASCII diagram of what I'm thinking right now. Please feel free to tear my design apart, I've really no idea what I'm doing :) Any advice is very welcome. edit: to be clear, the colo is providing redundant power with UPS and generator, so that's why there's no power gear in the plan, except for the 0U PDU that I didn't diagram. 42 | -- switch ---------------------- 41 | -- brush strip ----------------- 40 | ~~ reserved for second switch ~~ 39 | ~~ reserved for firewall ~~~~~~~ 38 | 37 | -- admin01 --------------------- 36 | 35 | -- vm01 ------------------------ 34 | -- vm02 ------------------------ 33 | ~~ reserved for vm03 ~~~~~~~~~~~ 32 | ~~ reserved for vm04 ~~~~~~~~~~~ 31 | ~~ reserved for vm05 ~~~~~~~~~~~ 30 | 29 | -- web01 ----------------------- 28 | -- web02 ----------------------- 27 | ~~ reserved for web03 ~~~~~~~~~~ 26 | ~~ reserved for web04 ~~~~~~~~~~ 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | -- db01 ------------------------ 15 | +- disks ----------------------+ 14 | +------------------------------+ 13 | ~~ reserved for more ~~~~~~~~~~~ 12 | ~~ db01 disks ~~~~~~~~~~~~~~~~~~ 11 | 10 | +- db02 -----------------------+ 9 | +------------------------------+ 8 | ~~ reserved for db02 ~~~~~~~~~~~ 7 | ~~ disks ~~~~~~~~~~~~~~~~~~~~~~~ 6 | ~~ reserved for more ~~~~~~~~~~~ 5 | ~~ db02 disks ~~~~~~~~~~~~~~~~~~ 4 | 3 | 2 | 1 |

    Read the article

  • Why can I not access the internet when Windows 7 finds no issue with the ethernet connection and the network can see my device?

    - by WannabeCoder
    So I just moved from a house to an apartment. In the house and the apartment I had Uverse set up - and in both I had my desktop connected via a ~40 foot long cat5 cable. However, upon moving to the apartment I found that my ethernet connection no longer provides internet. This would seem like a mundane problem if not for: The router can see the computer on the network Windows 7 (the desktop's OS) detects no problems with the ethernet connection. Connections over the internet (i.e. browser windows, Pandora, etc.) do not immediately fail. Instead they load for 2 minutes and then finally give up. Devices connected over the Wifi (PS4, Laptop) access the internet just fine While removing the cat5 cable from my house, I accidentally damaged the locking tab but managed to bend it back into the appropriate position. I would suspect that a bad cat5 cable might be to blame if not for the above issues (thought I've heard bad cat5 cables cause the most nonsensical problems) and the fact that I tested the cat5 cable by having it share internet between my laptop (working internet) to my desktop and it functioned just fine and provided the desktop with internet. My ipconfig /all successfully finds a default gateway, DHCP server, and DNS server. What could possibly be causing the problem?

    Read the article

  • Lag in Windows 7 with Zepto Znote 6224W

    - by Xink64
    Hi! Why does my Zepto Znote 6224W Laptop with Windows 7 make these small laggy moves whenever I use it? First I installed Windows 7 64 bit because of the memorycap in Windows 7 32 bit, but soon I realized that the system was lagging randomly. It was very annoying whenever I listened to music, because of the sudden lags. Then I tried everything with drivers; Chipset, Soundcard, Graphicscard, and so on. No luck. I then installed Windows 7 32 bit and this reduced the amount of lags but they are still here. I haven't tried bios upgrade since my bios should be newest according to now the now bankrupt Zepto company. My specifications: Zepto Znote 6224W Intel T8300 Intel Chipset PM965 PC-5300 4gb Nvidia 8600M GT Zepto's rebranded bios: Phoenix Technologies LTD Z14ND06 - Date: 12/20/2007 Harddrive: 320 GB 5400 RPM which I replaced with a Kingston SSDnow 40 GB. No luck either. I haven't tried Windows Vista on the machine though, but I would like to keep Windows 7.

    Read the article

  • Plesk 10 - creating and using vhost.conf

    - by MrFidge
    I'm having some issues setting up and using a vhost.conf for one of my domains. So far none of the domains have required any extra configuration but now I need to use a PEAR module, so I'm looking to include /usr/share/pear in the PHP settings for the domain. vhost file created in /var/www/vhosts/domain.com/conf/vhost.conf <Directory /var/www/vhosts/domain.com/httpdocs> php_admin_value include_path ".:/usr/share/pear" </Directory> I then restart Plesk using: /usr/local/psa/admin/sbin/websrvmng --reconfigure-vhost --vhost-name=domain.com Or as plesk says that command is obsolete in Plesk 10 I've tried using /usr/local/psa/admin/sbin/httpdmng --reconfigure-domain domain.com And for good luck I've restarted apache too each time. Net result - none of the PEAR includes work unless I edit the include_path in /etc/php.ini! Any tips on how to get this MOFO working? I've had a look through the documentation but TBH I just don't have time to read 40 pages of Plesk manual for one line of code, this can't be that hard, surely! Thanks for any pointers, H

    Read the article

  • ProCurve network expansion

    - by Blue Warrior NFB
    I've hit a bit of a wall with our network scale-out. As it stands right now: We have five ProCurve 2910al switches connected as above, but with 10GbE connections (two CX4, two fiber). This fully populates the central switch above, there will be no more 10GbE Ethernet connections from that device. This group of switches is not stacked (no stack directive). Sometime in the next two or three months I'll need to add a sixth, and I'm not sure how deep of a hole I'm in. Ideally I'd replace the core switch with something more capable and has more 10GbE ports. However, that's a major outage and that requires special scheduling. The two edge switches connected via fiber have dual-port 10GbE cards in them, so I could physically put another switch on the far end of one of those. I don't know how much of a good or bad idea that would be though. Is that too many segments between end-points? Some config-excerpts: Running configuration: ; J9147A Configuration Editor; Created on release #W.14.49 hostname "REDACTED-SW01" time timezone 120 module 1 type J9147A module 2 type J9008A module 3 type J9149A no stack trunk B1 Trk3 Trunk trunk B2 Trk4 Trunk trunk A1 Trk11 Trunk trunk A2 Trk12 Trunk vlan 15 name "VM-MGMT" untagged Trk2,Trk5,Trk7 ip helper-address 10.1.10.4 ip address 10.1.11.1 255.255.255.0 tagged 37-40,Trk3-Trk4,Trk11-Trk12 jumbo ip proxy-arp exit

    Read the article

  • Need help tuning Mysql and linux server

    - by Newtonx
    We have multi-user application (like MailChimp,Constant Contact) . Each of our customers has it's own contact's list (from 5 to 100.000 contacts). Everything is stored in one BIG database (currently 25G). Since we released our product we have the following data history. 5 years of data history : - users/customers (200+) - contacts (40 million records) - campaigns - campaign_deliveries (73.843.764 records) - campaign_queue ( 8 millions currently ) As we get more users and table records increase our system/web app is getting slower and slower . Some queries takes too long to execute . SCHEMA Table contacts --------------------+------------------+------+-----+---------+----------------+ | Field | Type | Null | Key | Default | Extra | +---------------------+------------------+------+-----+---------+----------------+ | contact_id | int(10) unsigned | NO | PRI | NULL | auto_increment | | client_id | int(10) unsigned | YES | | NULL | | | name | varchar(60) | YES | | NULL | | | mail | varchar(60) | YES | MUL | NULL | | | verified | int(1) | YES | | 0 | | | owner | int(10) unsigned | NO | MUL | 0 | | | date_created | date | YES | MUL | NULL | | | geolocation | varchar(100) | YES | | NULL | | | ip | varchar(20) | YES | MUL | NULL | | +---------------------+------------------+------+-----+---------+----------------+ Table campaign_deliveries +---------------+------------------+------+-----+---------+----------------+ | Field | Type | Null | Key | Default | Extra | +---------------+------------------+------+-----+---------+----------------+ | id | int(11) | NO | PRI | NULL | auto_increment | | newsletter_id | int(10) unsigned | NO | MUL | 0 | | | contact_id | int(10) unsigned | NO | MUL | 0 | | | sent_date | date | YES | MUL | NULL | | | sent_time | time | YES | MUL | NULL | | | smtp_server | varchar(20) | YES | | NULL | | | owner | int(5) | YES | MUL | NULL | | | ip | varchar(20) | YES | MUL | NULL | | +---------------+------------------+------+-----+---------+----------------+ Table campaign_queue +---------------+------------------+------+-----+---------+----------------+ | Field | Type | Null | Key | Default | Extra | +---------------+------------------+------+-----+---------+----------------+ | queue_id | int(10) unsigned | NO | PRI | NULL | auto_increment | | newsletter_id | int(10) unsigned | NO | MUL | 0 | | | owner | int(10) unsigned | NO | MUL | 0 | | | date_to_send | date | YES | | NULL | | | contact_id | int(11) | NO | MUL | NULL | | | date_created | date | YES | | NULL | | +---------------+------------------+------+-----+---------+----------------+ Slow queries LOG -------------------------------------------- Query_time: 350 Lock_time: 1 Rows_sent: 1 Rows_examined: 971004 SELECT COUNT(*) as total FROM contacts WHERE (contacts.owner = 70 AND contacts.verified = 1); Query_time: 235 Lock_time: 1 Rows_sent: 1 Rows_examined: 4455209 SELECT COUNT(*) as total FROM contacts WHERE (contacts.owner = 2); How can we optimize it ? Queries should take no more than 30 secs to execute? Can we optimize it and keep all data in one BIG database or should we change app's structure and set one single database to each user ? Thanks

    Read the article

  • Outside VPN traffic not able to ping site-to-site VPN remote site

    - by Siriss
    we have two ASA 5510s running 8.4 in a site-to-site VPN setup. All internal traffic is working smoothly. Site/Subnet A: 192.100.0.0 - local Site/Subnet B: 192.200.0.0 - remote VPN Users: 192.100.40.0 - assigned by ASA When you VPN into the network, all traffic hits Site A, and everything on subnet A is accessible. Site B however, is completely inaccessible for VPN users. All machines on subnet B, the firewall itself, etc... is not reachable by ping or otherwise. I know I am missing a NAT rule, and in 8.2, it was easy as pie to setup using ASDM, but now I can't get it for the life of me as 8.4 apparently made a lot of changes to NAT rules. I am not too comfortable in the ASA command line, but if there is a command I need to add or if you could direct me where I can add this in 8.4 ASDM I would really appreciate it. I have tired NAT Exempt, Static NAT, Static NAT Policies, etc... I think I tried all the options. I also might have my interfaces confused with the new look at feel of ASDM. Thank you much in advance and I hope I have been thorough enough.

    Read the article

  • UPS with a HP Proliant server

    - by Groo
    We placed a EATON Ellipse Max 1500 (900W) as the UPS for our HP Proliant ML350 G6. Upon first power failure (actually we only moved the UPS' input plug to a different socket), server immediatelly turned off, and the Health LED turned red and started blinking. UPS was in operation for about a week before that, with battery fully charged to 100%. Since our server's hot-plug supply is 460W, we are pretty sure we haven't overloaded it, the server was completely idle at that time (no web or win apps running except Windows Server core services). Then we tried to do the same with a different, no-name older PC (Core 2 Duo, 2Gb RAM) with a generic power supply (not sure what the power is) and it continued working when we pulled the plug out. UPS load was less than 15% (measured in the provided Eaton utility). We measured the UPS' output voltage using a smart oscilloscope and the THD of the UPS output waveform turned out to be 40%. Did you have similar experiences? Could this be a faulty UPS? Or a faulty power supply? Or some HP sensors configured to trigger too strictly? I wouldn't like replacing this UPS with the same brand, to get same results. [Edit] I also tried to do this while the server is turned off. While the UPS is working on battery, server will not start - as soon as I press the power button, Health LED starts blinking red.

    Read the article

  • AMD FX8350 CPU - CoolerMaster Silencio 650 Case - New Water Cooling System

    - by fat_mike
    Lately after a use of 6 months of my AMD FX8350 CPU I'm experiencing high temperatures and loud noise coming from the CPU fan(I set that in order to keep it cooler). I decided to replace the stock fan with a water cooling system in order to keep my CPU quite and cool and add one or two more case fans too. Here is my case's airflow diagram: http://www.coolermaster.com/microsite/silencio_650/Airflow.html My configuration now is: 2x120mm intake front(stock with case) 1x120mm exhaust rear(stock with case) 1 CPU stock I'm planning to buy Corsair Hydro Series H100i(www.corsair.com/en-us/hydro-series-h100i-extreme-performance-liquid-cpu-cooler) and place the radiator in the front of my case(intake) and add an 120mm bottom intake and/or an 140mm top exhaust fan. My CPU lies near the top of the MO. Is it a good practice to have a water-cooling system that takes air in? As you can see here the front of the case is made of aluminum. Can the fresh air go in? Does it even fit? If not, is it wiser to get Corsair Hydro Series H80i (www.corsair.com/en-us/hydro-series-h80i-high-performance-liquid-cpu-cooler) and place the radiator on top of my case(exhaust) and keep the front 2x120mm stock and add one more as intake on bottom. If you have any other idea let me know. Thank you. EDIT: The CPU fan running ~3000rpm and temp is around 40~43C on idle and save energy. When temp is going over 55C when running multiple programs and servers on localhost(tomcat, wamp) rpm is around 5500 and loud! I'm running Win8.1 CPU not overclocked PS: Due to my reputation i couldn't post the links that was necessary. I will edit ASAP.

    Read the article

  • fail2ban log parsing too slow on Raspberry Pi - options? [migrated]

    - by Gordon Morehouse
    I'm running fail2ban on a Raspberry Pi at 950MHz which I cannot overclock further. The Pi is occasionally subject to SYN floods on particular ports. I've set up iptables to throttle the rate of SYNs on the port of interest; when the throttle limits are exceeded, hosts which send SYNs are dropped into the REJECT chain and the particular SYN packet which exceeded the limit is logged. fail2ban then watches for these logged SYNs and, after seeing a few, temporarily bans the host for a short time (this is a transient issue in the app I'm working with). The problem is that the SYN floods can occasionally reach rates which are too fast for fail2ban to keep up with; I'll see 20-40 log messages per second, and eventually fail2ban falls behind and becomes ineffective. To add insult to injury, it continues consuming a LOT of CPU as it tries to catch up. I have verified that DROP chained packets from hosts already banned by fail2ban are not logged, and thus do not add to its load. What are my options here? I have a few ideas, but no clear path forward. Could I make the log-parse regex "easier" so it takes fewer cycles? Would using iptables --log-prefix to put a token near the start of the log message, and/or otherwise simplifying/altering the fail2ban regex help? Here is the current fail2ban config line containing a regex: failregex = kernel:.*?SRC=(?:::f{4,6}:)?(?P<host>[\w\-.^_]+) DST.*?SYN Is there a faster way for fail2ban to watch for the packets exceeding the limits than parsing kern.log? Could fail2ban be run under PyPy instead of CPython with minimal nonstandard wizardry (the OS is Raspbian 7, so, mostly Debian 7)? Is there something better than fail2ban that I could use to watch for the packets which exceed the SYN limits, and after N exceeds in X seconds, temporarily put the offending IP into the iptables DROP bucket, and take it out when the ban timer expires? Again, I'd vastly prefer a solution that uses as much software available in Debian as possible, though I can build Debian packages in a pinch.

    Read the article

  • Error during configuring kerberos5 using macports

    - by ario
    While trying to install libmemcached via MacPorts, I hit the following issue: libmemcached @0.40 +universal ---> Computing dependencies for libmemcached ---> Dependencies to be installed: cyrus-sasl2 kerberos5 ---> Configuring kerberos5 Error: org.macports.configure for port kerberos5 returned: configure failure: command execution failed Error: Failed to install kerberos5 It tells me to look in the log for details. Here's the last bit of the log file: :info:configure checking for setupterm in -lcurses... no :info:configure checking for setupterm in -lncurses... no :info:configure checking for tgetent... no :info:configure configure: error: Could not find tgetent; are you missing a curses/ncurses library? :info:configure configure: error: /bin/sh './configure' failed for appl/telnet :info:configure Command failed: cd "/opt/local/var/macports/build/_opt_local_var_macports_sources_rsync.macports.org_release_ports_net_kerberos5/kerberos5/work/krb5-1.7.2/src" && ./configure --prefix=/opt/local --disable-dependency-tracking --mandir=/opt/local/share/man :info:configure Exit code: 1 :error:configure org.macports.configure for port kerberos5 returned: configure failure: command execution failed :debug:configure Error code: NONE :debug:configure Backtrace: configure failure: command execution failed while executing "$procedure $targetname" :info:configure Warning: targets not executed for kerberos5: org.macports.activate org.macports.configure org.macports.build org.macports.destroot org.macports.install :error:configure Failed to install kerberos5 :debug:configure Registry error: kerberos5 not registered as installed & active. invoked from within "registry_active ${subport}" invoked from within "$workername eval registry_active \${subport}" :notice:configure Please see the log file for port kerberos5 for details: /opt/local/var/macports/logs/_opt_local_var_macports_sources_rsync.macports.org_release_ports_net_kerberos5/kerberos5/main.log It seems to say it's missing ncurses. Looks like it's there though, since if I run port installed I see these: ncurses @5.7_0 ncurses @5.9_1 (active) ncursesw @5.7_0 Any ideas on how to get around this error?

    Read the article

  • PostgreSQL lots of large Arrays and Writes

    - by strife911
    Hi, I am running a python program that spawns 8 threads and as each thread launch its own postmaster process via psycopg2. This is to maximize the use of my CPU-cores (8). Each thread call a series of SQL Functions. Most of these functions go through many thousands of rows each associated to a large FLOAT8[] Array (250-300) values by using unnest() and multiplying each FLOAT8 by an another FLOAT8 associated to each row. This Array approach minimized the size of the Indexes and the Tables. The Function ends with an Insert into another Table of a row of the same form (pk INT4, array FLOAT8[]). Some SQL Functions called by python will Update a row of these kind of Tables (with large Arrays). Now I currently have configured PostgreSQL to use most of the memory for cache (effective_cache_size of 57 GB I think) and only a small amount of it for shared memory (1GB I think). First, I was wondering what the difference between Cache and Shared memory was in regards to PostgreSQL (and my application). What I have noticed is that only about 20-40% of my total CPU processing power is used during the most Read intensive parts of the application (Select unnest(array) etc). So secondly, I was wondering what I could do to improve this so that 100% of the CPU is used. Based on my observations, it does not seem to have anything to do with python or its GIL. Thanks

    Read the article

  • Why is windows 7 rejecting my key?

    - by acidzombie24
    I'm extremely confused. I have a genuine key and CD (I can take photos) and I am trying to install windows on my new tower. I believe this would be the 3rd PC i installed it (old, laptop now new tower). However i did change the HDD once but i doubt windows would think its a different computer bc of that. After going through phone activation it said i installed it on to many pcs..... i'm extremely confused. I'll be happy to deactivate it off my old tower if i knew how. I already grabbed all the files off of it. I tried to look up the amount of boxes i can install windows home premium on and found this http://en.wikipedia.org/wiki/Windows_7_editions What stuck out was this Maximum physical CPUs supported[40] 1 1 1 2 2 2 My new tower has 4cores (its the intel i7) but has two threads each so it sees 8. Does that have anything to do with this? But apparently ultimate supports '2'. I'm sure windows support more than 2 cpus so... what gives? Actually its physically one CPU so i guess the number of cores doesn't matter? Why is windows 7 rejecting my key?

    Read the article

  • Login failed for user 'XXX' on the mirrored sql server

    - by hp17
    We have 4 web servers that host our asp.net (3.5) application. Randomly, we get error messages like : 1) "Login failed for user 'userid'" 2) "A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider: Named Pipes Provider, error: 40 - Could not open a connection to SQL Server)" we are running sql2005 and have a principle and a mirror db (sync). When these exceptions are thrown, I look at the SQL error logs on the mirrored db and noticed the failed login messages in there. The principle db is running fine and the other web apps are working great. this will happen for maybe 10 min, then the app pool recycles and it starts hitting the principle db again. Is there a configuration I have incorrect? my theory is that our principle db is forwarding the request to the mirror, but that should never happen. any help??

    Read the article

  • SYS-5016T-MTFB will not POST without manual assistance (Motherboard: X8STi-F)

    - by Dan
    I have a Supermicro 5016T-MTFB 1U server which I am in the process of setting up, but it has a really strange problem. When the system is powered on it will not POST until I press the reset button a few times, followed by pressing the delete key on the keyboard to "wake it up". If I power it on and do nothing, the fans spin up but nothing else happens at all. After pressing the reset button once, the red "overheat" light comes on and blinks which is supposed to indicate a fan failure - but all the fans are working. Pressing reset again usually stops the blinking, and the system starts the normal POST routine but it will not actually get to the bios screen unless I press delete. If I don't press delete, it just continues to hang. After pressing delete it will take me into the bios setup screen, if I exit without saving changes I can boot the system normally. I was able to successfully install Linux with no trouble...but upon rebooting the same problem happened again. This board has integrated IPMI which I thought was the problem, so I disabled it via the jumper on the board. Did not help. Each time this system powers on, it goes on for a second, then turns off again for another second, then turns back on again. I don't know why it does that. Here is what I put in the system: 1 x Xeon E5630 (Nehalem) 80W TDP (it's not overheating, CPU temps stay under 40 degrees C) 2 x Kingston 2GB x 3 DDR3-1066 Memory ECC, unbuffered, unregistered (kvr1066d3e7sk3/6g) 1 x Intel X25-M 160 GB 2 x Western Digital RE3 1TB

    Read the article

  • How can I tell which page is creating a high-CPU-load httpd process?

    - by Greg
    I have a LAMP server (CentOS-based MediaTemple (DV) Extreme with 2GB RAM) running a customized Wordpress+bbPress combination . At about 30k pageviews per day the server is starting to groan. It stumbled earlier today for about 5 minutes when there was an influx of traffic. Even under normal conditions I can see that the virtual server is sometimes at 90%+ CPU load. Using Top I can often see 5-7 httpd processes that are each using 15-30% (and sometimes even 50%) CPU. Before we do a big optimization pass (our use of MySQL is probably the culprit) I would love to find the pages that are the main offenders and deal with them first. Is there a way that I can find out which specific requests were responsible for the most CPU-hungry httpd processes? I have found a lot of info on optimization in general, but nothing on this specific question. Secondly, I know there are a million variables, but if you have any insight on whether we should be at the boundaries of performance with a single dedicated virtual server with a site of this size, then I would love to hear your opinion. Should we be thinking about moving to a more powerful server, or should we be focused on optimization on the current server?

    Read the article

  • Tomcat web application intermittent freeze

    - by tinny
    I have a Grails web application (just a standard war file) deployed on a Ubuntu 10.10 server running on tomcat 6. My database is postgresql. The problem is that every so often (once or twice a day after inactivity) when I try to log into this web application it just freezes. I can navigate to the login page but when I try and login (first time the DB is hit, might be a clue..?) the application just freezes indefinitely, no 500 response code... the browser just waits and waits. I followed the instructions detailed here because the problem described sounded the same as mine. My GC logging showed no long running GC, all sub sec. When the application freezes a jmap heap output is... using parallel threads in the new generation. using thread-local object allocation. Concurrent Mark-Sweep GC Heap Configuration: MinHeapFreeRatio = 40 MaxHeapFreeRatio = 70 MaxHeapSize = 536870912 (512.0MB) NewSize = 21757952 (20.75MB) MaxNewSize = 87228416 (83.1875MB) OldSize = 65404928 (62.375MB) NewRatio = 7 SurvivorRatio = 8 PermSize = 21757952 (20.75MB) MaxPermSize = 85983232 (82.0MB) Heap Usage: New Generation (Eden + 1 Survivor Space): capacity = 19595264 (18.6875MB) used = 11411976 (10.883308410644531MB) free = 8183288 (7.804191589355469MB) 58.23843965562291% used Eden Space: capacity = 17432576 (16.625MB) used = 9249296 (8.820816040039062MB) free = 8183280 (7.8041839599609375MB) 53.05754009046053% used From Space: capacity = 2162688 (2.0625MB) used = 2162680 (2.0624923706054688MB) free = 8 (7.62939453125E-6MB) 99.99963008996212% used To Space: capacity = 2162688 (2.0625MB) used = 0 (0.0MB) free = 2162688 (2.0625MB) 0.0% used concurrent mark-sweep generation: capacity = 101556224 (96.8515625MB) used = 83906080 (80.01907348632812MB) free = 17650144 (16.832489013671875MB) 82.62032270912317% used Perm Generation: capacity = 85983232 (82.0MB) used = 62866832 (59.95448303222656MB) free = 23116400 (22.045516967773438MB) 73.1152232100324% used Anyone know what "From Space:" is? Any ideas on further fault finding ideas? I dont have much experience with this type of fault finding.

    Read the article

  • Win 7 (SP1) Creationg of System Image failure... seems absurd. (0x80780119)

    - by DSKauai16
    This question seems to keep coming up in Microsoft Answers. Unfortunately, it never seems to be solved... on Microsoft Answers. Hopefully someone here will have a better idea. I'm trying to create a system image. It's not working. I have just re-installed windows as of a few hours ago. I have an admittedly older Western Digital 148 GB USB portable HDD which is not just completely empty, but I even did a long format with the NTFS file system just to be sure. The reinstallation of windows and a couple of programs take up 40 GB (seen below) When I try to create a System Image onto the USB HDD, I am told that there is not enough room. Obviously, this is wrong. The screen captures show exactly the steps that are happening to lead me to 0x80780119. I haven't done anything but put on Windows 7 (32bit; SP1) and install some programs. I haven't even done anything with them. There's almost zero in the way of data, and I checked that yes, the HDD works to accept data, send data and work with data. I've used the drive successfully for a long, long time. What's going wrong?

    Read the article

  • Switch Windows 8 from a hybrid MBR/GPT => GPT only on Macbook Pro Retina

    - by Sid
    I used DiskUtility+Bootcamp Wizard to setup my hard drive for Windows 8 (final MSDN). Somewhere in that process, the Apple tools turned my GPT disk into a hybrid MBR/GPT. All my 4 primary MBR partitions are used up, so when I try turning on Bitlocker in Windows 8, it complains about not finding a System drive. I know on Windows 8 the Bitlocker setup tries to create the 200(?)MB system partition if it's missing. However with all 4 partitions filled I suspect it can't create system drive = it can't find it = throws back an error like "BitLocker Setup could not find a target system drive. You may need to manually prepare your drive for BitLocker". I've already tried disabling hibernation, swap file etc. Now I'm thinking that if I were to get rid of the MBR scheme altogether, perhaps I can be alright within the GPT world without MBR's 4 primary partitions limit. So, how can I get rid of the MBR tables on the hybrid scheme in a manner that still leaves Mac OS and Windows 8 in working conditions? Details: Hardware is the MacbookPro Retina. Primary MBR partitions are consumed as follows: EFI partition HFS+ partition (=encrypted, therefore ="Apple_CoreStorage") HFS+ partition (Recovery partition, contains unencrypted Mac bootloader) NTFS partition (Windows8 all-in-one partition) diskutil list output sid-mbpr:~ sid$ diskutil list /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *251.0 GB disk0 1: EFI 209.7 MB disk0s1 2: Apple_CoreStorage 160.0 GB disk0s2 3: Apple_Boot Recovery HD 650.0 MB disk0s3 4: Microsoft Basic Data Win8 90.1 GB disk0s4 GPT vs MBR addresses sid-mbpr:~ sid$ sudo gptsync /dev/rdisk0 Password: Current GPT partition table: # Start LBA End LBA Type 1 40 409639 EFI System (FAT) 2 409640 312909639 Unknown 3 312909640 314179175 Mac OS X Boot 4 314179584 490233855 Basic Data Current MBR partition table: # A Start LBA End LBA Type 1 1 409639 ee EFI Protective 2 409640 312909639 ac Apple RAID 3 312909640 314179175 ab Mac OS X Boot 4 * 314179584 490233855 07 NTFS/HPFS Status: GPT partition of type 'Unknown' found, will not touch this disk.** **: Ignore this message, the gptsync tool is old and doesn't understand the UUID for "Apple_CoreStorage" / FileVault2 partitions. Since LBA addresses are alright, safe to ignore this message.

    Read the article

  • can not connect to SQL running on amazon ec2 machine

    - by njj56
    I am using SQL managment studio 2008 running on an Amazon EC2 machine. I am unable to connect to the database in my asp.net application. The EC2 instance has been set to accept connections over the SQL port. I am also able to remote the machine as well as view websites hosted on the server. Listed below is part of the connection string relating to this instance. When the program is ran and this connection string is called, it returns tcp error 0 - no return response. it just times out. <add name="ProjectServer" connectionString="Data Source=*IP ADDRESS HERE*,1433;Initial Catalog=*Catalog Name*;User ID=IP-0A6ED514\Administrator;"/> I removed the ip and the catalog name for the example, but I am sure they are correct. The only thing that I could think may cause an error, is the differences in names between the user id and the server name - the server name is ip-0A6ED514\sharepoint but the user name is ip-0A6ED514\administrator when I log into the sql server manager on the EC2 instance. A password is not used. Not sure if I would need to leave in a blank string for password - also not sure if the difference between server name and user id to log in makes a difference. Any help is appreciated. Thank you. update - when this connection string is used with out the port, i get tcp provider error 40 - when the port is in there, i get error 0 edit- the sql server is using windows authentication - does this make a difference? Usually I always use SQL server authentication

    Read the article

  • fast way to find network user computer on domain hogging all wan bandwidth

    - by dasko
    i have a network of about 40 domain users and i have huge latency wan issues, like 1400ms for google.com pings. I have noticed that the problem goes away after everyone goes home for the day. I would like to know if i should use something like a hub with wireshark on the router or modem to see if there are any irregular activity. I am open to suggestions but i need to isolate which user has the bug. I am assuming it is either downloads or someone spamming out heavily and not knowing. It would be best to trace to ip number so i can just look into dns and find the pc hostname with the problem? This is the first client i have this problem with so never really needed to address it before but not suprised as users don't actually listen to any best practices that we have suggested. Please help, thanks. just to update, pc's to routers and other computers have ping latency of 1ms so it is right after i hit the wan, using tracert to a web site (random), that i get the massive delay in the responses. As well this is a dsl line with 5mb down and 650kb up (maybe upload saturation?) thanks.

    Read the article

  • Windows typeperf and pound signs.

    - by Weegee
    I'm currently trying to use typeperf to access some Windows performance counters. Unfortunately, a few of the instances I'm trying to check are of the format service#1. The command typeperf "\\server\Process(service#1)\Working Set Peak" is unfortunately returning the data for \\server\Process(service)\Working Set Peak rather than the data for the instance service#1. This holds true for any of the services that have pound signs in the counter string. Does anyone know of a method to get around this problem? Sample output: I:\>typeperf -s server "\Process(service#1)\Working Set" "(PDH-CSV 4.0)","\\server\Process(service)\Working Set" "10/08/2009 09:37:29.070","1643274240.000000" "10/08/2009 09:37:30.070","1643274240.000000" "10/08/2009 09:37:31.070","1643274240.000000" The command completed successfully. I:\>typeperf -s server "\Process(service#2)\Working Set" "(PDH-CSV 4.0)","\\server\Process(service)\Working Set" "10/08/2009 09:37:39.273","1643274240.000000" "10/08/2009 09:37:40.273","1643274240.000000" "10/08/2009 09:37:41.273","1643274240.000000" "10/08/2009 09:37:42.273","1643274240.000000" "10/08/2009 09:37:43.273","1643274240.000000" The command completed successfully. I can confirm in PerfMon that the Working Set value "1643274240.000000" is incorrect for both service#1 and service#2. I am running Windows XP Service Pack 2, but a co-worker who is running Windows Server 2003 was having the same troubles.

    Read the article

  • Ubuntu 10.04 server delay responding to AJAX requests

    - by DanielAttard
    I manage a Ubuntu 10.04 server with a couple of domains hosted on it. As I continue to learn more about all these wonderful new (for me), one issue that I have begun to notice is the delay it sometimes takes for the server to respond to certain requests. As an example, when I view the timeline of events using firebug I can see that most of the time when I make a POST, the server responds in under 100ms. Sometimes, however, there is a substantial delay before the RESPONSE from the server. I can't seem to tell when the delay will happen and when it won't, however, when it happens the delay is always for about 4.5 seconds. The delay seems to happen about 30-40% of the time. Here is the section of apache2.conf dealing with logs: # # The following directives define some format nicknames for use with # a CustomLog directive (see below). # If you are behind a reverse proxy, you might want to change %h into %{X-Forwarded-For}i # LogFormat "%v:%p %h %l %u %t \"%r\" %>s %O \"%{Referer}i\" \"%{User-Agent}i\"" vhost_combined LogFormat "%h %l %u %t \"%r\" %>s %O \"%{Referer}i\" \"%{User-Agent}i\"" combined LogFormat "%h %l %u %t \"%r\" %>s %O" common LogFormat "%{Referer}i -> %U" referer LogFormat "%{User-agent}i" agent I have no idea where to look to try and debug this problem or investigate further. Any suggestions?

    Read the article

  • Why do I have 55 local area connections in ipconfig?

    - by RMorrisey
    Windows Vista Home Premium. I should mention that I am having no problem whatever getting an internet connection. When I type "ipconfig" in the console, I get (55!) messages of 3 lines each, listing a ton of disconnected network connections. My PC only has one network card. Each message looks like this: Tunnel adapter Local Area Connection* 55: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : These don't cause a major problem; they make it a pain, though, to fish upward and find my IP address. How can I get rid of them? Edit: Actually, a few connection numbers are randomly missing from the sequence; so, it's really more like 30 or 40 connection messages, rather than all 55. Not sure why that is, either.

    Read the article

  • Set up WLAN in 3-level house

    - by Balint Erdi
    I'm having a hard time setting up the network in our house. It has three levels (basement, ground floor, first level). The WLAN is set up by an ASUS RT-N12 router which provides perfect coverage for the ground floor and the basement. However, I set up my "home office" in the basement where the signal barely arrived. So I purchased a TP-Link TL-WA901ND (300 Mbps) Access Point which I set up in the other corner of the ground floor to expand the ASUS router's range. I used the AP's Repeater mode for that. The distance between my computer and the TP-Link AP is 6-7 meters. There is a staircase going down from the ground floor to the basement so there are no solid walls between the computer and the AP. This setup mostly works (I am writing this from the basement) but it is not reliable (the signal strength sometimes goes down to ~40% of the max) sometimes so I wonder if I am doing it correctly or if there is a better way. Screenshot of the router's and the AP's dashboard screen follow: Any comments on what I am doing wrong or hints for improvement are appreciated. Thank you. UPDATE Tried one more thing, setting up the TP-LINK AP in Access Point mode. That way, I can make it use a different SSID. I enabled WDS/Bridge so that it expands the range of the ASUS router (see screenshot). That does not work, either, if I connect to the network set up by the TP-LINK device (PELSTER-2), I can't reach the external network (the Internet). It seems the problem always comes back to this, the TP-LINK does not have access to the external network, whatever its mode of operation.

    Read the article

< Previous Page | 141 142 143 144 145 146 147 148 149 150 151 152  | Next Page >