Search Results

Search found 10481 results on 420 pages for 'port mirroring'.

Page 15/420 | < Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >

  • Threaded Python port scanner

    - by Amnite
    I am having issues with a port scanner I'm editing to use threads. This is the basics for the original code: for i in range(0, 2000): s = socket(AF_INET, SOCK_STREAM) result = s.connect_ex((TargetIP, i)) if(result == 0) : c = "Port %d: OPEN\n" % (i,) s.close() This takes approx 33 minutes to complete. So I thought I'd thread it to make it run a little faster. This is my first threading project so it's nothing too extreme, but I've ran the following code for about an hour and get no exceptions yet no output. Am I just doing the threading wrong or what? import threading from socket import * import time a = 0 b = 0 c = "" d = "" def ScanLow(): global a global c for i in range(0, 1000): s = socket(AF_INET, SOCK_STREAM) result = s.connect_ex((TargetIP, i)) if(result == 0) : c = "Port %d: OPEN\n" % (i,) s.close() a += 1 def ScanHigh(): global b global d for i in range(1001, 2000): s = socket(AF_INET, SOCK_STREAM) result = s.connect_ex((TargetIP, i)) if(result == 0) : d = "Port %d: OPEN\n" % (i,) s.close() b += 1 Target = raw_input("Enter Host To Scan:") TargetIP = gethostbyname(Target) print "Start Scan On Host ", TargetIP Start = time.time() threading.Thread(target = ScanLow).start() threading.Thread(target = ScanHigh).start() e = a + b while e < 2000: f = raw_input() End = time.time() - Start print c print d print End g = raw_input()

    Read the article

  • Serial Port Data Structure

    - by Seth Archer
    I need to send data to a hardware device over serial port. I'm using a program called serial port tool for os x. After I connect to the device there is a form box where I can type data to send. I have no idea how to format the data. Here is an excerpt from the manual for the device. "The Net Manager Command structure consists of one start byte, one command byte, five bytes of data, and a one byte checksum. Each message packet is formatted as follows:" an example command is: Byte0=30 Byte1=7 Byte2=5 Byte3=1 Byte4=2 Byte5=0 Byte6=245 How do I type that into the form box in serial port tool? Thanks, Seth

    Read the article

  • Accessing Bluetooth virtual COM port on Windows without manual pairing

    - by oo_olo_oo
    I need to connect to a Bluetooth device through virtual COM port created in Windows. It's easy when the port has been already created during manual pairing procedure. But I would like my application to relieve an user from the manual pairing of a device. I would like to present all devices in the range, allow user to chose one, and then create virtual COM port connected with the selected device. I'm not trying to avoid the pairing procedure itself, but rather I would like to invoke it by my application. I started getting familiar with Microsoft Bluetooth API. And then some doubts arose. I've been wondering what happen if some user would use different (than Microsoft's) Bluetooth stack? Is the Microsoft's API the real Bluetooth API, which have to be implemented by any other Bluetooth stack provider? Or rather each provider has its own API, and the Microsoft's is only one of many other?

    Read the article

  • how do i claim a low-numbered port as non-root the "right way"

    - by qbxk
    I have a script that I want to run as a daemon listening on a low-numbered port (< 1024) Script is in python, though answers in perl are also acceptable. The script is being daemonized using start-stop-daemon in a startup script, which may complicate the answer What I really (think) don't want is to type ps -few and see this process running with a "root" on it's line. How do I do it? ( from my less-than-fully-educated-about-system-calls perspective, I can see 3 avenues, Run the script as root (no --user/--group/--chuid to start-stop-daemon), and have it de-escalate it's user after it claims the port Setuid root on the script (chmod u+s), and run the script as the running user, (via --user/--group/--chuid to start-stop-daemon, the startup script still has to be called as root), in the script, acquire root privileges, claim the port, and then revert back to normal user something else i'm unaware of )

    Read the article

  • System.UnauthorizedAccessException from Serial Port in VB.NET

    - by psuhas
    I am using VB.NET 2008 Express Edition to access Serial Port which is a USB to Serial port. Since this is removable, the app user can disconnect it at any time in app. I am getting an unhandled exception when I remove the USB Serial Port. After research, it seems like a known problem in .NET (even in 3.5) I am looking for some solution to get this done. I have already tried the app.config solution that was suggested and it does not work Here is the link for issue http://connect.microsoft.com/VisualStudio/feedback/Validation.aspx?FeedbackID=140018

    Read the article

  • Default http/admin port in dropwizard project

    - by mithrandir
    I have a dropwizard project and I have maintained a config.yml file at the ROOT of the project (basically at the same level as pom.xml). Here I have specified the HTTP port to be used as follows: http: port:9090 adminPort:9091 I have the following code in my TestService.java file public class TestService extends Service<TestConfiguration> { @Override public void initialize(Bootstrap<TestConfiguration> bootstrap) { bootstrap.setName("test"); } @Override public void run(TestConfiguration config, Environment env) throws Exception { // initialize some resources here.. } public static void main(String[] args) throws Exception { new TestService().run(new String[] { "server" }); } } I expect the config.yml file to be used to determine the HTTP port. However the app always seems to start with the default ports 8080 and 8081. Also note that I am running this from eclipse. Any insights as to what am I doing wrong here ?

    Read the article

  • Serial Port Not getting closed. I want to release the COM port ...

    - by sunil
    Serial Port Not getting closed. I want to release the COM port ... Below is my code.... import java.io.*; import java.util.*; import gnu.io.*; public class ReadCommPort implements SerialPortEventListener { static CommPortIdentifier portId; static Enumeration portList; InputStream inputStream; OutputStream outputStream; public SerialPort serialPort; List byteList = new ArrayList(); public static Message message = null; public void readData() { boolean portFound = false; String defaultPort = "COM1"; portList = CommPortIdentifier.getPortIdentifiers(); while ( portList.hasMoreElements() ) { portId = ( CommPortIdentifier )portList.nextElement(); if ( portId.getPortType() == CommPortIdentifier.PORT_SERIAL ) { if ( portId.getName().equals( defaultPort ) ) { System.out.println( "Found port: " + defaultPort ); portFound = true; buildSerialPort(); } } } if ( ! portFound ) { System.out.println( "port " + defaultPort + " not found." ); } } public void buildSerialPort() { try { serialPort = (SerialPort) portId.open( "ReadCommPort", 1 ); inputStream = serialPort.getInputStream(); outputStream = serialPort.getOutputStream(); serialPort.addEventListener( this ); serialPort.notifyOnDataAvailable(true); serialPort.setSerialPortParams( 2400, SerialPort.DATABITS_7, SerialPort.STOPBITS_1, SerialPort.PARITY_NONE ); } catch ( Exception e ) { e.printStackTrace(); } } @SuppressWarnings("unchecked") public void serialEvent( SerialPortEvent event ) { switch ( event.getEventType() ) { case SerialPortEvent.BI: System.out.println( "BI"); break; case SerialPortEvent.OE: System.out.println( "OE"); break; case SerialPortEvent.FE: System.out.println( "FE"); break; case SerialPortEvent.PE: System.out.println( "PE"); break; case SerialPortEvent.CD: System.out.println( "CD"); break; case SerialPortEvent.CTS: System.out.println( "CTS"); break; case SerialPortEvent.DSR: System.out.println( "DSR"); break; case SerialPortEvent.RI: System.out.println( "RI"); break; case SerialPortEvent.OUTPUT_BUFFER_EMPTY: System.out.println( "OUTPUT_BUFFER_EMPTY"); break; case SerialPortEvent.DATA_AVAILABLE : try { int len = inputStream.available(); byte[] readBuffer = new byte[ len ]; // processing data code.. // close the port // release all resources... serialPort.removeEventListener(); try { serialPort.addEventListener( null ); } catch (TooManyListenersException e) { e.printStackTrace(); } inputStream.close(); outputStream.close(); serialPort.close(); } catch ( IOException e ) { e.printStackTrace(); } break; } } public static void main(String[] args) { new ReadCommPort().readData(); } }

    Read the article

  • Port 5357 TCP on Windows 7 professional 64 bit?

    - by Registered
    Is there a reason this port is open, a quick Nmap scan and Nessus scan reveal it's open, why? Are there any ramifications if I close this port via the firewall rule set? Or does anyone here now more info about this port besides Google? WTF? 1)http://www.symantec.com/connect/blogs/who-left-tunnel-door-open-windows-firewall-vista-0 I know the talk is about Vista, but I am pretty sure it's the same port on 7, also. 2)Port 5357 common errors:The port is vulnerable to info leak problems allowing it to be accessed remotely by malicious authors. (Web Services for Devices) I am blocking this crap, if I have issues will just re-enable. Damn windows. Inbound rule for Network Discovery to allow WSDAPI Events via Function Discovery. [TCP 5357] You just got blocked, until I break something, will see. Time to re-Nmap and re-Nessus. Nmap scan 0 open ports after closing Port 5357,Win7 still works for now, one more scan with Nessus just to make sure all is well.

    Read the article

  • How to create a restricted SSH user for port forwarding?

    - by Lekensteyn
    ændrük suggested a reverse connection for getting an easy SSH connection with someone else (for remote help). For that to work, an additional user is needed to accept the connection. This user needs to be able to forward his port through the server (the server acts as proxy). How do I create a restricted user that can do nothing more than the above described? The new user must not be able to: execute shell commands access files or upload files to the server use the server as proxy (e.g. webproxy) access local services which were otherwise not publicly accessible due to a firewall kill the server Summarized, how do I create a restricted SSH user which is only able to connect to the SSH server without privileges, so I can connect through that connection with his computer?

    Read the article

  • How to create a restricted SSH user for port forwarding?

    - by Lekensteyn
    ændrük suggested a reverse connection for getting an easy SSH connection with someone else (for remote help). For that to work, an additional user is needed to accept the connection. This user needs to be able to forward his port through the server (the server acts as proxy). How do I create a restricted user that can do nothing more than the above described? The new user must not be able to: execute shell commands access files or upload files to the server use the server as proxy (e.g. webproxy) access local services which were otherwise not publicly accessible due to a firewall kill the server Summarized, how do I create a restricted SSH user which is only able to connect to the SSH server without privileges, so I can connect through that connection with his computer?

    Read the article

  • Lenovo W520 back usb port not working

    - by jaudette
    The usb port in the back of my laptop (on the right side when viewed from using perspective) is not working. Does anybody know if we can get this port working, and what the port number is. Here is my lsusb, if it can help. % lsusb Bus 001 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 003 Device 002: ID 046d:c01e Logitech, Inc. MX518 Optical Mouse Bus 003 Device 003: ID 046d:c318 Logitech, Inc. Illuminated Keyboard Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 001 Device 003: ID 0765:5001 X-Rite, Inc. Huey PRO Colorimeter Bus 001 Device 004: ID 147e:2016 Upek Biometric Touchchip/Touchstrip Fingerprint Sensor Bus 001 Device 005: ID 0a5c:217f Broadcom Corp. Bluetooth Controller Bus 001 Device 006: ID 04f2:b217 Chicony Electronics Co., Ltd Lenovo Integrated Camera (0.3MP) Bus 002 Device 003: ID 17ef:1003 Lenovo Integrated Smart Card Reader I am running 12.10, upgraded from 12.04 but it did not work either in 12.04. The two usb ports on the left work just fine. EDIT: I just updated my bios from 1.32 to 1.39, no change in behaviour. The port does not even power up my devices. EDIT 2: Booted up windows, and the port is working. I went into the device manager and looked at the USB settings. I found my USB drive on Port 2, Hub 3, i just don't know how that relates to the Bus and Device numbers of linux. In windows, Smart card reader was on USB hub located at port 1 hub 2, fingerprint and bluetooth were on USB hub located at port 1 hub 1 EDIT 3: Went and looked at this SO post. Tried to look at my kern.log file with tail -f /var/log/kern.log. Got some activity when plugging/removing devices in other ports, but nothing happens when connecting a device into that port. It really looks disabled. Looked at my usb1-4 sys/bus/usb/devices/usb1/power/control and they are all set on auto. As expected, usb4 have version 3.00, the others (usb1-usb3) are 2.00.

    Read the article

  • Monitor a COM port already in use.

    - by rross
    Is it possible to read from a COM port already in use on Windows XP? I would like to see the communication between some software and a device plugged into a serial device. I wrote a small program using C# to monitor the COM, but once it's in use by the other device it will not let you open it again. How can one monitor a COM port already in use? I'm open to 3rd party software. Thanks

    Read the article

  • Find a free port C#

    - by Alon
    How does IPEndPoint finds a free port when I do new IPEndPoint(IPAddress.Any, 0), for example? Is it possible to find a free port from a range, without the GetActiveTcpConnections method? because it is slow - I need a faster way to do this. Thanks.

    Read the article

  • VB6 Serial port programming

    - by commodus86
    I'm not much experienced in VB6 serial port programming. I need to control another circuit through serial port. (I have heard that pin 4 and pin 7 are used for that purpose. If these pins are incorrect please tell me what pins are used for such purposes) My requirement is to set those pins to high or low and read their levels(high or low) through VB6 program. How to do the task?? Thanx,

    Read the article

  • Java: Cannot listen to port, BindException

    - by bguiz
    Hi, I am developing an application in Netbeans, and it is using JavaDB. I can connect to it and execute queries without issues, but for some reason, the "Output - JavaDB Database Process" pane within Netbeans keeps displaying Security manager installed using the Basic server security policy. Could not listen on port 1527 on host localhost: java.net.BindException: Address already in use How do I find out what process is already using, or bound to, that port number?

    Read the article

  • FILE_NOT_FOUND when trying to open COM port C++

    - by Moutabreath
    I am trying to open a com port for reading and writing using C++ but I can't seem to pass the first stage of actually opening it. I get an INVALID_HANDLE_VALUE on the handle with GetLastError FILE_NOT_FOUND. I have searched around the web for a couple of days I'm fresh out of ideas. I have searched through all the questions regarding COM on this website too. I have scanned through the existing ports (or so I believe) to get the name of the port right. I also tried combinations of _T("COM1") with the slashes, without the slashes, with colon, without colon and without the _T I'm using windows 7 on 64 bit machine. this is the code i got I'll be glad for any input on this void SendToCom(char* data, int len) { DWORD cbNeeded = 0; DWORD dwPorts = 0; EnumPorts(NULL, 1, NULL, 0, &cbNeeded, &dwPorts); //What will be the return value BOOL bSuccess = FALSE; LPCSTR COM1 ; BYTE* pPorts = static_cast<BYTE*>(malloc(cbNeeded)); bSuccess = EnumPorts(NULL, 1, pPorts, cbNeeded, &cbNeeded, &dwPorts); if (bSuccess){ PORT_INFO_1* pPortInfo = reinterpret_cast<PORT_INFO_1*>(pPorts); for (DWORD i=0; i<dwPorts; i++) { //If it looks like "COMX" then size_t nLen = _tcslen(pPortInfo->pName); if (nLen > 3) { if ((_tcsnicmp(pPortInfo->pName, _T("COM"), 3) == 0) ){ COM1 =pPortInfo->pName; //COM1 ="\\\\.\\COM1"; HANDLE m_hCommPort = CreateFile( COM1 , GENERIC_READ|GENERIC_WRITE, // access ( read and write) 0, // (share) 0:cannot share the COM port NULL, // security (None) OPEN_EXISTING, // creation : open_existing FILE_FLAG_OVERLAPPED, // we want overlapped operation NULL // no templates file for COM port... ); if (m_hCommPort==INVALID_HANDLE_VALUE) { DWORD err = GetLastError(); if (err == ERROR_FILE_NOT_FOUND) { MessageBox(hWnd,"ERROR_FILE_NOT_FOUND",NULL,MB_ABORTRETRYIGNORE); } else if(err == ERROR_INVALID_NAME) { MessageBox(hWnd,"ERROR_INVALID_NAME",NULL,MB_ABORTRETRYIGNORE); } else { MessageBox(hWnd,"unkown error",NULL,MB_ABORTRETRYIGNORE); } } else{ WriteAndReadPort(m_hCommPort,data); } } pPortInfo++; } } } }

    Read the article

  • Sharing serial port (Modem protocol + dialer)

    - by debita
    Hi, I wanted to use this code to send archives with Xmodem: http://www.java2s.com/Code/Java/Network-Protocol/JModemsimplecommunicationsprogram.htm In this case, I want to establish a dialup connection between two computers and send a binary file. But this code doesn't let me set a phone number to dial after i setup the port and before I transfer the file. Is there any way of sharing the port with another application that dials the phone number?

    Read the article

  • Server port 16080 problem: webserver adds the port number 16080 in the URL

    - by Juri
    Hello everybody. On my wordpress website one little thing doesn't work. Sometimes the Webserver adds the port number 16080 in the URL, which leads to an error (network timeout). Wrong: http://www.example.com:16080/about-us/weekly-program/?month=may&yr=2010 Correct: http://www.example.com/about-us/weekly-program/?month=may&yr=2010 Has someone a "Server port 16080 problem fix"? Is it possible, that I need to add a ServerName directive to the config file to tell the domain name of the server? Cheers Juri !!!update!!! PS: Here is the site configuration, don't ask me to change the 16080 to 80, because that screwes up everyone else's websites... Please let me know what you think of the configuration: ## Default Virtual Host Configuration <VirtualHost *:16080> ServerName example.com ServerAdmin [email protected] DocumentRoot "/Library/WebServer/Documents/WMsites/example.com/wordpress" DirectoryIndex "index.html" "index.php" CustomLog "/var/log/httpd/access_log" "%{PC-Remote-Addr}i %l %u %t \"%r\" %>s %b" ErrorLog "/var/log/httpd/error_log" ErrorDocument 404 /error.html <IfModule mod_ssl.c> SSLEngine Off SSLLog "/var/log/httpd/ssl_engine_log" SSLCertificateFile "/etc/certificates/Default.crt" SSLCertificateKeyFile "/etc/certificates/Default.key" SSLCipherSuite "ALL:!ADH:RC4+RSA:+HIGH:+MEDIUM:+LOW:!SSLv2:+EXP:+eNULL" </IfModule> <IfModule mod_dav.c> DAVLockDB "/var/run/davlocks/.davlock100" DAVMinTimeout 600 </IfModule> <Directory "/Library/WebServer/Documents/WMsites/example.com/wordpress"> Options All -Indexes -ExecCGI -Includes +MultiViews <IfModule mod_dav.c> DAV Off </IfModule> AllowOverride All </Directory> <IfModule mod_rewrite.c> RewriteEngine On RewriteCond %{REQUEST_METHOD} ^TRACE RewriteRule .* - [F] </IfModule> <IfModule mod_alias.c> </IfModule> LogLevel warn ServerAlias www.example.com ServerAlias example.com </VirtualHost>

    Read the article

  • why can't I open a port on Win 7? is it the app's fault?

    - by rjnagle
    I am having problems opening a port from one Windows PC on my local network. On Windows 7 computer ("Computer A") I running Calibre, an ebook management program that has something called an "ebook content server" . In essence, it serves via the web a content catalog. From Computer A, I can access the content server on localhost. ie. http://127.0.0.1:8787 calls up the content server successfully. With ipconfig I have confirmed that its local IP address is 192.168.1.106 From Computer B (a Vista Machine) I can ping 192.168.1.106 I have tried opening/editing a port in the Windows Firewall several times. In Windows firewall -- Allowed Programs in Control Panel, I see a listing for Calibre (with both Home/Work and PUblic checked) In details, I see Name: Calibre, Port Number 8787, Protocol TCP If I use the Advanced Security configuration screen for the firewall, I created an Inbound Rule on Computer A for Calibre (with the settings I indicated). If I run this command line on Computer A, I see: netstat -a -n TCP 0.0.0.0:554 0.0.0.0:0 LISTENING TCP 0.0.0.0:664 0.0.0.0:0 LISTENING TCP 0.0.0.0:2869 0.0.0.0:0 LISTENING TCP 0.0.0.0:3306 0.0.0.0:0 LISTENING TCP 0.0.0.0:5357 0.0.0.0:0 LISTENING TCP 0.0.0.0:6570 0.0.0.0:0 LISTENING TCP 0.0.0.0:6580 0.0.0.0:0 LISTENING TCP 0.0.0.0:8787 0.0.0.0:0 LISTENING TCP 0.0.0.0:10243 0.0.0.0:0 LISTENING TCP 192.168.1.106:63020 74.125.227.51:80 TIME_WAIT TCP [::]:80 [::]:0 LISTENING TCP [::]:135 [::]:0 LISTENING TCP [::]:443 [::]:0 LISTENING TCP [::]:445 [::]:0 LISTENING TCP [::]:554 [::]:0 LISTENING TCP [::]:2869 [::]:0 LISTENING TCP [::]:5357 [::]:0 LISTENING TCP [::]:6570 [::]:0 LISTENING TCP [::]:6580 [::]:0 LISTENING TCP [::]:10243 [::]:0 LISTENING TCP [::]:49152 [::]:0 LISTENING TCP [::]:49153 [::]:0 LISTENING TCP [::]:49154 [::]:0 LISTENING TCP [::]:49155 [::]:0 LISTENING TCP [::]:49170 [::]:0 LISTENING And lots of other junk, but this seems relevant, I see port 80 is open (I run xampp apache web server for windows on Machine A) This is the only time I see port 8787 referenced from the netstat commmand. From Windows Computer B, I can, ping 192.168.1.106 and even view http://drupal.local (on Computer A) and http://192.168.1.106/ (which goes to the Xampp config screen on Computer A). But I cannot access via Computer B htttp://192.168.1.106:8787 or htttp://computerhosta:8787 So what is going wrong? Is this a problem with the Calibre application or have I incorrectly opened the port? What things could possibly interfere with the opening of this port? On a sidenote, I have tried using telnet from Computer B to see if port 80 or 8787 is open for 192.168.1.106. I get no reply for either one. Thanks.

    Read the article

  • SPAN/Port mirroring on Linksys switch

    - by Bastien974
    Hi all, I'm trying to deploy a Snort box in my LAN. I have a Linksys SRW248G4 and trying to configure Port mirroring so that Snort can listen everything on the network in promiscuous mode. So in ADMIN / Port Mirroring, I have 3 things: Source Port (e1,...e48, g1...g4) Type (Rx, Tx, Both) Target (e1...e48, g1...g4) Last time I played with it, I killed all traffic on the switch, I had to reboot it several times... so now I'm asking question before: Do I need to configure each Source Port (from 1 to 48) to forward to the single promiscuous port ? 48 rules !? Is that correct ? Thanks !

    Read the article

  • Reading from serial port with Boost Asio?

    - by trikri
    Hi! I'm going to check for incoming messages (data packages) on the serial port, using Boost Asio. Each message will start with a header that is one byte long, and will specify which type of the message has been sent. Each different type of message has an own length. The function I'm about to write should check for new incoming messages continually, and when it finds one it should read it, and then some other function should parse it. I thought that the code might look something like this: void check_for_incoming_messages() { boost::asio::streambuf response; boost::system::error_code error; std::string s1, s2; if (boost::asio::read(port, response, boost::asio::transfer_at_least(0), error)) { s1 = streambuf_to_string(response); int msg_code = s1[0]; if (msg_code < 0 || msg_code >= NUM_MESSAGES) { // Handle error, invalid message header } if (boost::asio::read(port, response, boost::asio::transfer_at_least(message_lengths[msg_code]-s1.length()), error)) { s2 = streambuf_to_string(response); // Handle the content of s1 and s2 } else if (error != boost::asio::error::eof) { throw boost::system::system_error(error); } } else if (error != boost::asio::error::eof) { throw boost::system::system_error(error); } } Is boost::asio::streambuf is the right thing to use? And how do I extract the data from it so I can parse the message? I also want to know if I need to have a separate thread which only calls this function, so that it get called more often? Isn't there a risk for loosing data in between two calls to the function otherwise, because so much data comes in that it can't be stored in the serial ports memory? I'm using Qt as a widget toolkit and I don't really know how long time it needs to process all it's events.

    Read the article

< Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >