Search Results

Search found 25534 results on 1022 pages for 'write powershell'.

Page 150/1022 | < Previous Page | 146 147 148 149 150 151 152 153 154 155 156 157  | Next Page >

  • API Auth vs User Auth

    - by user1626384
    I have read many posts and articles on this topic but still cant connect the dots. I want to make a Rails app that is strictly a JSON API maybe using Sinatra or the rails-api gem. I also want to make both a web client app and an iPhone app which consumes the API. No plans on letting third party dev's use it. So I could create a separate username/password combination for both the web and mobile client and use HTTP Basic over SSL. Each app would have these values as configs in the source and use it to authenticate to the API so only these can make a call. Anyone else trying would get a 401 error returned. This would be considered handling the API authentication. The web and mobile client apps allow end users to sign up and read/write data to the API. When each user is created, I create and save a token in their profile. If a user successfully signs in, I send back the token. On each future read/write then also send along this token in the header. I get the token and lookup the user in the database and make the read/write. Does this sound like an appropriate way to handle it. For the web client, when I initially send back the token, where do I store it. In a cookie? Do I also drop a cookie to handle session state?

    Read the article

  • Free CodeSmith License!

    - by Randy Walker
    The catch?  Attend the Ozarks .Net User Group meeting on April 1st. Here’s a list of the other prizes for the event GRAND PRIZE 1 - iPad (Wi-Fi 16GB) THIRD PARTY COMPONENTS 6 - Telerik Premium Collection 5 - Infragistics NetAdvantage for .NET 1 - Nevron Chart for .NET Lite DevExpress Xceed PRODUCTIVITY 2 - CodeRush with Refactor! Pro 2 - ReSharper CodeSmith GAMES 3 - Halo3 ODST (XBox 360) 3 - Forza Motorsport (Xbox 360) OTHER SOFTWARE 3 - Windows 7 Ultimate 2 - Microsoft Office Standard 2007 HARDWARE 2 - Microsoft Arc Mouse BOOKS 12 - OReilly eBooks 12 - Microsoft Press books 5 - Apress books 3 - Addison-Wesley books 2 - Manning books 2 - Sams books The Info: "Be a Professional Developer and Write Clean Code!" by Claudio Lassala on April 1, 2010 PRESENTATION TOPIC "Be a Professional Developer and Write Clean Code!" - by Claudio Lassala Poorly written code can be created quickly, but it comes at a cost of high maintenance. Most of the time, code can be improved easily by following some simple practices. Professional developers should know these practices and tools and apply it to their work every day. This session will cover the importance of writing clean code, the kind of attitude all developers should have towards the code they produce, as well as the practices and tools that can be used to aid you in becoming a better developer. BIOGRAPHY Claudio Lassala is a Senior Developer at EPS Software Corp. He has presented several lectures at Microsoft events such as PDC Brazil and various other Microsoft seminars, as well as several conferences and user groups across North America and Brazil. He is a multiple winner of the Microsoft MVP Award since 2001 (for Visual FoxPro in 2001-2002, and for C# ever since), an INETA speaker, and also holds the MCSD for .NET certification. He has articles published on several magazines, such as MSDN Brazil Magazine, CoDe Magazine, UTMag, Developers Magazine, and FoxPro Advisor. More detailed information regarding his presentations and articles can be found in his MVP Profile. You can also read more about Claudio on his blog or on Twitter Schedule 5:30 PM – 6:30 PM Social Networking 6:30 PM - 7:00 PM  Prizes 7:00 PM - 8:30 PM Presentation:  "Be a Professional Developer and Write Clean Code!" by Claudio Lassala 8:30 PM - 9:00 PM Wrap-Up

    Read the article

  • How big can my SharePoint 2010 installation be?

    - by Sahil Malik
    Ad:: SharePoint 2007 Training in .NET 3.5 technologies (more information). 3 years ago, I had published “How big can my SharePoint 2007 installation be?” Well, SharePoint 2010 has significant under the covers improvements. So, how big can your SharePoint 2010 installation be? There are three kinds of limits you should know about Hard limits that cannot be exceeded by design. Configurable that are, well configurable – but the default values are set for a pretty good reason, so if you need to tweak, plan and understand before you tweak. Soft limits, you can exceed them, but it is not recommended that you do. Before you read any of the limits, read these two important disclaimers - 1. The limit depends on what you’re doing. So, don’t take the below as gospel, the reality depends on your situation. 2. There are many additional considerations in planning your SharePoint solution scalability and performance, besides just the below. So with those in mind, here goes.   Hard Limits - Zones per web app 5 RBS NAS performance Time to first byte of any response from NAS must be less than 20 milliseconds List row size 8000 bytes driven by how SP stores list items internally Max file size 2GB (default is 50MB, configurable). RBS does not increase this limit. Search metadata properties 10,000 per item crawled (pretty damn high, you’ll never need to worry about it). Max # of concurrent in-memory enterprise content types 5000 per web server, per tenant Max # of external system connections 500 per web server PerformancePoint services using Excel services as a datasource No single query can fetch more than 1 million excel cells Office Web Apps Renders One doc per second, per CPU core, per Application server, limited to a maximum of 8 cores.   Configurable Limits - Row Size Limit 6, configurable via SPWebApplication.MaxListItemRowStorage property List view lookup 8 join operations per query Max number of list items that a single operation can process at one time in normal hours 5000 Configurable via SPWebApplication.MaxItemsPerThrottledOperation   Also you get a warning at 3000, which is configurable via SPWebApplication.MaxItemsPerThrottledOperationWarningLevel   In addition, throttle overrides can be requested, throttle overrides can be disabled, and time windows can be set when throttle is disabled. Max number of list items for administrators that a single operation can process at one time in normal hours 20000 Configurable via SPWebApplication.MaxItemsPerThrottledOperationOverride Enumerating subsites 2000 Word and Powerpoint co-authoring simultaneous editors 10 (Hard limit is 99). # of webparts on a page 25 Search Crawl DBs per search service app 10 Items per crawl db 25 million Search Keywords 200 per site collection. There is a max limit of 5000, which can then be modified by editing the web.config/client.config. Concurrent # of workflows on a content db 15. Workflows running in the timer service are not counted in this limit. Further workflows are queued. Can be configured via the Set-SPFarmConfig powershell commandlet. Number of events picked by the workflow timer job and delivered to workflows 100. You can increase this limit by running additional instances of the workflow timer service. Visio services file size 50MB Visio web drawing recalculation timeout 120 seconds Configurable via – Powershell commandlet Set-SPVisioPerformance Visio services minimum and maximum cache age for data connected diagrams 0 to 24 hours. Default is 60 minutes. Configurable via – Powershell commandlet Set-SPVisioPerformance   Soft Limits - Content Databases 300 per web app Application Pools 10 per web server Managed Paths 20 per web app Content Database Size 200GB per Content DB Size of 1 site collection 100GB # of sites in a site collection 250,000 Documents in a library 30 Million, with nesting. Depends heavily on type and usage and size of documents. Items 30 million. Depends heavily on usage of items. SPGroups one SPUser can be in 5000 Users in a site collection 2 million, depends on UI, nesting, containers and underlying user store AD Principals in a SPGroup 5000 SPGroups in a site collection 10000 Search Service Instances 20 Indexed Items in Search 100 million Crawl Log entries 100 million Search Alerts 1 million per search application Search Crawled Properties 1/2 million URL removals in search 100 removals per operation User Profiles 2 million per service application Social Tags 500 million per social database Comment on the article ....

    Read the article

  • Setting up Pure-FTPd with admin/user permissions for same directory

    - by modulaaron
    I need to set up 2 Pure-FTPd accounts - ftpuser and ftpadmin. Both will have access to a directory that contains 2 subdirectories - upload and downlaod. The permissions criteria needs to be as follows: ftpuser can upload to /upload but cannot view the contents (blind drop). ftpuser can download from /download but cannot write to it. ftpadmin has full read/write permissions to both, including file deletion Currently, the first two are not a problem - disabling /upload read access and /download write access for ftpuser did the job. The problem is that when a file is uploaded by ftpuser, it's permissions are set to 644, meaning that user ftpadmin can only read it (note that all FTP directories are chown'd to ftpuser:ftpadmin). How can I give ftpadmin the power he so rightfully deserves?

    Read the article

  • Outlook DASL Filter - Custom Search

    - by Ryan B
    I'm trying to write a DASL filter to combine three queries: Get all mail with no category and no flag. ("urn:schemas-microsoft-com:office:office#Keywords" IS NULL AND "urn:schemas:httpmail:messageflag" IS NULL) Get all mail that is categorized as "Ryan" and flagged with a red "Today" flag. Don't know how to write this one. Get all mail that is uncategorized and flagged with a red "Today" flag. Don't know how to write this one. Once I have the individual queries, I will combine and OR them. I am stuck on how to filter the flag value.

    Read the article

  • Third year in a row- Microsoft MVP again!!

    - by Jalpesh P. Vadgama
    Today is Sunday and I was not expecting this as today is holiday although I know it was Microsoft Mvp renewal day. At evening I got the congratulation email from the Microsoft. Yeah!! I am Microsoft Most Valuable Professional again. I got the same message as a part of Mvp. Thanks Microsoft again. Dear Jalpesh Vadgama, Congratulations! We are pleased to present you with the 2012 Microsoft® MVP Award! This award is given to exceptional technical community leaders who actively share their high quality, real world expertise with others. We appreciate your outstanding contributions in Visual C# technical communities during the past year. Feeling is again same as first time. I am going to dedicated this award to my family. My parents who always inspired me to do new things. My wife who scarifies her time to write blogs. My brother who support me in every possible way.  On this occasion, I would also like to thanks my reader without their support it was no possible to achieve this. Thanks for reading my blog!!. Please do keep reading this. I will try to write as much as possible. I would also like to thanks ‘Tanmay Kapoor’ My Mvp lead for continuous support.     Once again thank you all for your continuous support and love. There are lots of new technologies in Microsoft Stack and I am going to write lots of blog post about all the new stuff. So stay tuned for the same.

    Read the article

  • SharePoint Apps and Windows Azure

    - by ScottGu
    Last Monday I had an opportunity to present as part of the keynote of this year’s SharePoint Conference.  My segment of the keynote covered the new SharePoint Cloud App Model we are introducing as part of the upcoming SharePoint 2013 and Office 365 releases.  This new app model for SharePoint is additive to the full trust solutions developers write today, and is built around three core tenants: Simplifying the development model and making it consistent between the on-premises version of SharePoint and SharePoint Online provided with Office 365. Making the execution model loosely coupled – and enabling developers to build apps and write code that can run outside of the core SharePoint service. This makes it easy to deploy SharePoint apps using Windows Azure, and avoid having to worry about breaking SharePoint and the apps within it when something is upgraded.  This new loosely coupled model also enables developers to write SharePoint applications that can leverage the full capabilities of the .NET Framework – including ASP.NET Web Forms 4.5, ASP.NET MVC 4, ASP.NET Web API, EF 5, Async, and more. Implementing this loosely coupled model using standard web protocols – like OAuth, JSON, and REST APIs – that enable developers to re-use skills and tools, and easily integrate SharePoint with Web and Mobile application architectures. A video of my talk + demos is now available to watch online: In the talk I walked through building an app from scratch – it showed off how easy it is to build solutions using new SharePoint application, and highlighted a web + workflow + mobile scenario that integrates SharePoint with code hosted on Windows Azure (all built using Visual Studio 2012 and ASP.NET 4.5 – including MVC and Web API). The new SharePoint Cloud App Model is something that I think is pretty exciting, and it is going to make it a lot easier to build SharePoint apps using the full power of both Windows Azure and the .NET Framework.  Using Windows Azure to easily extend SaaS based solutions like Office 365 is also a really natural fit and one that is going to offer a bunch of great developer opportunities.  Hope this helps, Scott  P.S. In addition to blogging, I am also now using Twitter for quick updates and to share links. Follow me at: twitter.com/scottgu

    Read the article

  • Writing to the UI with MonoDroid using RunOnUIThread

    - by Wallym
    I've been pulling my hair out over the past day or so trying to update the UI in my test app.  I was having problem after problem.  I finally got down to my base problem.  I could not write out to my TextView.  WTF could be causing that?  I can write to my UI in other parts of my app.  This is pure craziness.  I thought long and hard and nothing was coming to me.  Wait, the light bulb went on.  I am in the wrong thread.  Great, how do I write in the correct thread?  MonoDroid supports the entire AsyncTask set of objects, but this seemed like overkill.  I was reading and came across RunOnUIThread().......Bing..........The lightbulb has been invented...BlueStar Airlines (oh wait, wrong context). Anyway, here is what I needed:this.RunOnUiThread(() => TextViewControl.Text = "Hello World"); Enjoy!!!!!!!  Remember kiddies, running on the main ui for off device operations is bad, not as bad as crossing the streams bad, but bad as in trying to drive on a flat tire bad. It won't kill you, but it does keep you from getting anywhere.

    Read the article

  • CoffeeScript Test Framework

    - by Liam McLennan
    Tonight the Brisbane Alt.NET group is doing a coding dojo. I am hoping to talk someone into pairing with me to solve the kata in CoffeeScript. CoffeeScript is an awesome language, half javascript, half ruby, that compiles to javascript. To assist with tonight’s dojo I wrote the following micro test framework for CoffeeScript: <html> <body> <div> <h2>Test Results:</h2> <p class='results' /> </div> <script src="http://ajax.googleapis.com/ajax/libs/jquery/1.3.2/jquery.min.js" type="text/javascript"></script> <script type="text/coffeescript"> # super simple test framework test: { write: (s) -> $('.results').append(s + '<br/>') assert: (b, message...) -> test.write(if b then "pass" else "fail: " + message) tests: [] exec: () -> for t in test.tests test.write("<br/><b>$t.name</b>") t.func() } # add some tests test.tests.push { name: "First Test" func: () -> test.assert(true) } test.tests.push { name: "Another Test" func: () -> test.assert(false, "You loose") } # run them test.exec(test.tests) </script> <script type="text/javascript" src="coffee-script.js"></script> </body> </html> It’s not the prettiest, but as far as I know it is the only CoffeeScript test framework in existence. Of course, I could just use one of the javascript test frameworks but that would be no fun. To get this example to run you need the coffeescript compiler in the same directory as the page.

    Read the article

  • What happens to modern-ui apps when they aren't in the foreground?

    - by Mark Allen
    If I start a modern-ui app and then switch to a different app or a normal program running on the desktop, what happens to the first app? I've heard something about the first app being suspended, but realized that I don't really know that for certain. I mean, could you write a SETI@Home (BOINC) app if you wanted to, or will apps that aren't in the foreground always be suspended? Can you change that? I could see changing that based on available resources, running from AC vs. battery, etc. This morning I heard about an iPad being recovered thanks to the "Find my iPad" app, and was wondering whether you could write such a thing as a modern-ui app and have it work without being the running foreground app. (I'm aware that you'd just write a Windows service or similar, that's not what I'm asking about.)

    Read the article

  • Is there any desktop version available for wsywyg editors

    - by user825904
    I have been searching for long and i am not able to find one editor which i can always keep open for daily notes keeping with some codes and which highlights the code Just like we have our editor where we ask questions. ALl is want is I can write some text as normal Then i have few php code which i can write and then click some code button or like we have ctrl +K and i gets higlighted then on the same page i write some paragraph text as normal withoout higligting and some bullet points Then again i get some c++ code and i wrap that around on the same page and page grows daily Currently i use notepad++ and it does not support syntx higlighting of different langages on same page and on individual blocks. it highights all the file even the normal text as well basically i am looking wsywyg editor but as windows desktop application

    Read the article

  • Ultrium 3 tape drive shoe-shining, 3Mb/s: and it's not the cable

    - by mowsala
    I have a HP 960 Ultrium 3 tape drive. Since I got it, (second hand, £90) I've been experiencing shoe-shining. Writing with tar in Linux, I average about 3Mb/s write speed. I've tried replacing both the SCSI card and the cable now, both of which made no difference at all. A curiuos observation I have made is that the write rate is not consistent. Sometimes it will write for over a minute without shoeshining, but more often, just a few seconds. I've also tried several tapes, different source drives, and even writing from Windows Backup, to no avail.

    Read the article

  • How do I setup sendmail, postfix, or dovecot so that perl can send emails?

    - by M. Tibbits
    Direct Question: I want to enable Perl to send emails. What package(s) should I install to setup a simplistic email server: no need for incoming, only outgoing. I can forward through gmail's SMTP if that's best? Background: I am programmer with a nightly build script written in Perl. I would like to email myself the results of my nightly builds (especially if there's an error). I've read about the perl package Mail::Sendmail briefly, but if something else is more appropriate, please tell me!! I tried the simple aptget install sendmail, but that doesn't seem to work. I get the following errors: Server said: 421 4.3.0 collect: Cannot write ./dfp1PFXl7W020719 (bfcommit, uid=0, gid=120): No such file or directory message transmission error (421 4.3.0 collect: Cannot write ./dfp1PFXl7W020719 (bfcommit, uid=0, gid=120): No such file or directory ) Server said: 421 4.3.0 collect: Cannot write ./dfp1PFXl7W020719 (bfcommit, uid=0, gid=120): No such file or directory I've googled this problem a bit and tried a few things -- adding my username to /etc/mail/trusted-users and such, but to no avail. In other words, I would be most grateful if you could provide simple instructions for setting up an outgoing mail server. I really don't understand the specifics, but as I understand, I need to forward the mail through an existing SMTP server -- so I can use my gmail account if need be (that's where I want to send the logs anyway). Any suggestions would be most greatly appreciated.

    Read the article

  • Organizations &amp; Architecture UNISA Studies &ndash; Chap 7

    - by MarkPearl
    Learning Outcomes Name different device categories Discuss the functions and structure of I/.O modules Describe the principles of Programmed I/O Describe the principles of Interrupt-driven I/O Describe the principles of DMA Discuss the evolution characteristic of I/O channels Describe different types of I/O interface Explain the principles of point-to-point and multipoint configurations Discuss the way in which a FireWire serial bus functions Discuss the principles of InfiniBand architecture External Devices An external device attaches to the computer by a link to an I/O module. The link is used to exchange control, status, and data between the I/O module and the external device. External devices can be classified into 3 categories… Human readable – e.g. video display Machine readable – e.g. magnetic disk Communications – e.g. wifi card I/O Modules An I/O module has two major functions… Interface to the processor and memory via the system bus or central switch Interface to one or more peripheral devices by tailored data links Module Functions The major functions or requirements for an I/O module fall into the following categories… Control and timing Processor communication Device communication Data buffering Error detection I/O function includes a control and timing requirement, to coordinate the flow of traffic between internal resources and external devices. Processor communication involves the following… Command decoding Data Status reporting Address recognition The I/O device must be able to perform device communication. This communication involves commands, status information, and data. An essential task of an I/O module is data buffering due to the relative slow speeds of most external devices. An I/O module is often responsible for error detection and for subsequently reporting errors to the processor. I/O Module Structure An I/O module functions to allow the processor to view a wide range of devices in a simple minded way. The I/O module may hide the details of timing, formats, and the electro mechanics of an external device so that the processor can function in terms of simple reads and write commands. An I/O channel/processor is an I/O module that takes on most of the detailed processing burden, presenting a high-level interface to the processor. There are 3 techniques are possible for I/O operations Programmed I/O Interrupt[t I/O DMA Access Programmed I/O When a processor is executing a program and encounters an instruction relating to I/O it executes that instruction by issuing a command to the appropriate I/O module. With programmed I/O, the I/O module will perform the requested action and then set the appropriate bits in the I/O status register. The I/O module takes no further actions to alert the processor. I/O Commands To execute an I/O related instruction, the processor issues an address, specifying the particular I/O module and external device, and an I/O command. There are four types of I/O commands that an I/O module may receive when it is addressed by a processor… Control – used to activate a peripheral and tell it what to do Test – Used to test various status conditions associated with an I/O module and its peripherals Read – Causes the I/O module to obtain an item of data from the peripheral and place it in an internal buffer Write – Causes the I/O module to take an item of data form the data bus and subsequently transmit that data item to the peripheral The main disadvantage of this technique is it is a time consuming process that keeps the processor busy needlessly I/O Instructions With programmed I/O there is a close correspondence between the I/O related instructions that the processor fetches from memory and the I/O commands that the processor issues to an I/O module to execute the instructions. Typically there will be many I/O devices connected through I/O modules to the system – each device is given a unique identifier or address – when the processor issues an I/O command, the command contains the address of the address of the desired device, thus each I/O module must interpret the address lines to determine if the command is for itself. When the processor, main memory and I/O share a common bus, two modes of addressing are possible… Memory mapped I/O Isolated I/O (for a detailed explanation read page 245 of book) The advantage of memory mapped I/O over isolated I/O is that it has a large repertoire of instructions that can be used, allowing more efficient programming. The disadvantage of memory mapped I/O over isolated I/O is that valuable memory address space is sued up. Interrupts driven I/O Interrupt driven I/O works as follows… The processor issues an I/O command to a module and then goes on to do some other useful work The I/O module will then interrupts the processor to request service when is is ready to exchange data with the processor The processor then executes the data transfer and then resumes its former processing Interrupt Processing The occurrence of an interrupt triggers a number of events, both in the processor hardware and in software. When an I/O device completes an I/O operations the following sequence of hardware events occurs… The device issues an interrupt signal to the processor The processor finishes execution of the current instruction before responding to the interrupt The processor tests for an interrupt – determines that there is one – and sends an acknowledgement signal to the device that issues the interrupt. The acknowledgement allows the device to remove its interrupt signal The processor now needs to prepare to transfer control to the interrupt routine. To begin, it needs to save information needed to resume the current program at the point of interrupt. The minimum information required is the status of the processor and the location of the next instruction to be executed. The processor now loads the program counter with the entry location of the interrupt-handling program that will respond to this interrupt. It also saves the values of the process registers because the Interrupt operation may modify these The interrupt handler processes the interrupt – this includes examination of status information relating to the I/O operation or other event that caused an interrupt When interrupt processing is complete, the saved register values are retrieved from the stack and restored to the registers Finally, the PSW and program counter values from the stack are restored. Design Issues Two design issues arise in implementing interrupt I/O Because there will be multiple I/O modules, how does the processor determine which device issued the interrupt? If multiple interrupts have occurred, how does the processor decide which one to process? Addressing device recognition, 4 general categories of techniques are in common use… Multiple interrupt lines Software poll Daisy chain Bus arbitration For a detailed explanation of these approaches read page 250 of the textbook. Interrupt driven I/O while more efficient than simple programmed I/O still requires the active intervention of the processor to transfer data between memory and an I/O module, and any data transfer must traverse a path through the processor. Thus is suffers from two inherent drawbacks… The I/O transfer rate is limited by the speed with which the processor can test and service a device The processor is tied up in managing an I/O transfer; a number of instructions must be executed for each I/O transfer Direct Memory Access When large volumes of data are to be moved, an efficient technique is direct memory access (DMA) DMA Function DMA involves an additional module on the system bus. The DMA module is capable of mimicking the processor and taking over control of the system from the processor. It needs to do this to transfer data to and from memory over the system bus. DMA must the bus only when the processor does not need it, or it must force the processor to suspend operation temporarily (most common – referred to as cycle stealing). When the processor wishes to read or write a block of data, it issues a command to the DMA module by sending to the DMA module the following information… Whether a read or write is requested using the read or write control line between the processor and the DMA module The address of the I/O device involved, communicated on the data lines The starting location in memory to read from or write to, communicated on the data lines and stored by the DMA module in its address register The number of words to be read or written, communicated via the data lines and stored in the data count register The processor then continues with other work, it delegates the I/O operation to the DMA module which transfers the entire block of data, one word at a time, directly to or from memory without going through the processor. When the transfer is complete, the DMA module sends an interrupt signal to the processor, this the processor is involved only at the beginning and end of the transfer. I/O Channels and Processors Characteristics of I/O Channels As one proceeds along the evolutionary path, more and more of the I/O function is performed without CPU involvement. The I/O channel represents an extension of the DMA concept. An I/O channel ahs the ability to execute I/O instructions, which gives it complete control over I/O operations. In a computer system with such devices, the CPU does not execute I/O instructions – such instructions are stored in main memory to be executed by a special purpose processor in the I/O channel itself. Two types of I/O channels are common A selector channel controls multiple high-speed devices. A multiplexor channel can handle I/O with multiple characters as fast as possible to multiple devices. The external interface: FireWire and InfiniBand Types of Interfaces One major characteristic of the interface is whether it is serial or parallel parallel interface – there are multiple lines connecting the I/O module and the peripheral, and multiple bits are transferred simultaneously serial interface – there is only one line used to transmit data, and bits must be transmitted one at a time With new generation serial interfaces, parallel interfaces are becoming less common. In either case, the I/O module must engage in a dialogue with the peripheral. In general terms the dialog may look as follows… The I/O module sends a control signal requesting permission to send data The peripheral acknowledges the request The I/O module transfers data The peripheral acknowledges receipt of data For a detailed explanation of FireWire and InfiniBand technology read page 264 – 270 of the textbook

    Read the article

  • How do I measure performance of a virtual server?

    - by Sergey
    I've got a VPS running Ubuntu. Being a virtual server, I understand that it shares resources with unknown number of other servers, and I'm noticing that it's considerably slower than my desktop machine. Is there some tool to measure the performance of the virtual machine? I'd be curious to see some approximate measure similar to bogomips, possibly for CPU (operations/sec), memory and disk read/write speed. I'd like to be able to compare those numbers to my desktop machine. I'm not interested in the specs of the actual physical machine my VPS is running on - by doing cat /proc/cpuinfo I can see that it's a nice quad-core Xeon machine, but it doesn't matter to me. I'm basically interested in how fast a program would run in my VPS - how many CPU operations it can make in a second, how many bytes to write to RAM or to disk. I only have ssh access to the machine so the tool need to be command-line. I could write a script which, say, does some calculations in a loop for a second and counts how many loops it was able to do, or something similar to measure disk and RAM performance. But I'm sure something like this already exists.

    Read the article

  • Practical RAID Performance?

    - by wag2639
    I've always thought the following to be a general rule of thumb for RAID: RAID 0: Best performance for READ and WRITE from stripping, greatest risk RAID 1: Redundant, decent for READ (I believe it can read from different parts of a file from different hard drives), not the best for WRITE RAID 0+1 (01): combines redundancy of RAID 1 with performance of RAID 0 RAID 1+0 (10): slightly better version of RAID 0+1 RAID 5: good READ performance, bad WRITE performance, redundant IS THIS ASSUMPTION CORRECT? (and how do they compare to a JBOD setup for R/W IO performance) Are certain practical RAID setups better for different applications: gaming, video editing, database (Acccess or SQL)? I was thinking about hard disk drives but does this apply to solid state drives as well?

    Read the article

  • Create Hidden Partition on USB

    - by Francesco
    I need to split an USB flash disk into two USB drives, each one with its own drive letter, but one of these has to be hidden. In the non-hidden partition I want to place my software, and in the hidden partition I need to place some files that are required by the software in order to work. Moreover, only the software may read, write, delete or execute the files in this partition. I thought to use a little partition viewed as a CD-ROM drive, as they do in many flash drives, but this solution does not allow to write other data in a second moment, and it's visible to the user that can read the file. Obviously the software must be able to access to partition and read, write, delete or execute the content. Is there a solution to do so, possibly that work also on Linux?

    Read the article

  • CSS and HTML incoherences when declaring multiple classes

    - by Cesco
    I'm learning CSS "seriously" for the first time, but I found the way you deal with multiple CSS classes in CSS and HTML quite incoherent. For example I learned that if I want to declare multiple CSS classes with a common style applied to them, I have to write: .style1, .style2, .style3 { color: red; } Then, if I have to declare an HTML tag that has multiple classes applied to it, I have to write: <div class="style1 style2 style3"></div> And I'm asking why? From my personal point of view it would be more coherent if both could be declared by using a comma to separate each class, or if both could be declared using a space; after all IMHO we're still talking about multiple classes, in both CSS and HTML. I think that it would make more sense if I could write this to declare a div with multiple classes applied: <div class="style1, style2, style3"></div> Am I'm missing something important? Could you explain me if there's a valid reason behind these two different syntaxes?

    Read the article

  • Step by Step screencasts to do Behavior Driven Development on WCF and UI using xUnit

    - by oazabir
    I am trying to encourage my team to get into Behavior Driven Development (BDD). So, I made two quick video tutorials to show how BDD can be done from early requirement collection stage to late integration tests. It explains breaking user stories into behaviors, and then developers and test engineers taking the behavior specs and writing a WCF service and unit test for it, in parallel, and then eventually integrating the WCF service and doing the integration tests. It introduces how mocking is done using the Moq library. Moreover, it shows a way how you can write test once and do both unit and integration tests at the flip of a config setting. Watch the screencast here: Doing BDD with xUnit, Subspec and on a WCF Service  Warning: you might hear some noise in the audio in some places. Something wrong with audio bit rate. I suggest you let the video download for a while and then play it. If you still get noise, go back couple of seconds earlier and then resume play. It eliminates the noise.  The next video tutorial is about doing BDD to do automated UI tests. It shows how test engineers can take behaviors and then write tests that tests a prototype UI in isolation (just like Service Contract) in order to ensure the prototype conforms to the expected behaviors, while developers can write the real code and build the real product in parallel. When the real stuff is done, the same test can test the real stuff and ensure the agreed behaviors are satisfied. I have used WatiN to automate UI and test UI for expected behaviors. Doing BDD with xUnit and WatiN on a ASP.NET webform Hope you like it!

    Read the article

  • SQL 2008 Replication over Internet

    - by Akash Kava
    We have decided to put our servers in data centers on east and west coast of US, to keep high level redundancy. After evaluating number of replication options, apart from VPN there is no other way to do replication for SQL Server. We are investigating VPN but I have following questions. Our Large DB consists of media information (pictures/movies/audio/pdf) etc, so we are not very concerned about security because they are not financial sensitive data. SQL 2005 supports or can be configured to support replication over internet? If Yes then should we downgrade to 2005? If SQL 2008 Publisher is configured for Web Sync, can we write an automatic program (C# Windows Service) to act as pull subscriber and run on the subscriber server and replicate subscriber database? Or are there any API available in SQL where we can write our own program to do replication in very generic way? (In a nut shell, can we write our own C# Windows Service based Subscriber program?)

    Read the article

  • Use 3 monitors w/built-in intel adapter + two old nvidia PCI cards on 10.10?

    - by Kendall Gifford
    I'd like to move from windows with my current workstation. The only thing holding me back is that I have 3 monitors connected to the system and I really take advantage of the real estate when working. I just installed Ubuntu 10.10 on the system and one of the monitors is up and running just fine. This monitor is connected to the built-in Intel adapter. I also have two old nVidia GeForce4 MX 4000 (nv19pl) cards in my two PCI slots with two monitors connected to them respectively. I installed the legacy (and proprietary) nVidia drivers (the nvidia-96 package) that claims to support these old cards. Now the question is how to get X configured to use all adapters (using two different drivers) so I can use all three monitors (and is this even possible)? From what I've read, it looks like I'll have to write an xorg.conf file since the nVidia driver doesn't support the auto-magic configuration supported by other drivers. On this site: http://wiki.ubuntu.com/X/Config it says that on 10.10 I just need to write an xorg.conf "containing only those sections and options that you need to override Xorg's autoconfigurated settings". So, does this mean I can get away with only including the nVidia-specific configuration stuff and all else will get auto-configured? Or, will providing a config with a "Device" section overrule the auto-magic from detecting/using the Intel adapter? I ran the included nvidia-xconfig to generate a basic, nVidia-specific xorg.conf but I'm hesitant to reboot with it in place, suspecting I'll have a screwed up display. Also, is there any way (any tool or command) to generate an xorg.conf from the current, auto-configured running state of an X session? If I have to write a full, complete config, I'd rather start with one that includes everything that's been auto-detected thus far (and merge it with my nVidia version). Anyhow, any info and thoughts are greatly appreciated (as are answers).

    Read the article

  • SVN do unnecessary chmod on .svn/tempfiles

    - by ???
    My working dir is on an TrueCrypt NTFS volume, with umask 000. So I can read/write on any files with no problem. But I can't do svn command on it, for example `svn update' shows error: svn: Can't set permissions on '.svn/tempfile.8.tmp': strace svn up gives: ... chmod("sbin/.svn/tempfile.2.tmp", 0770) = -1 EPERM (Operation not permitted) fcntl64(3, F_GETFL) = 0x2 (flags O_RDWR) fcntl64(3, F_SETFL, O_RDWR|O_NONBLOCK) = 0 write(3, "( failure ( ( 1 76:Can't set per"..., 172) = 172 fcntl64(3, F_GETFL) = 0x802 (flags O_RDWR|O_NONBLOCK) fcntl64(3, F_SETFL, O_RDWR) = 0 read(3, "( abort-edit ( ) ) ( failure ( ("..., 4096) = 191 gettimeofday({1276661368, 382789}, NULL) = 0 lstat64("sbin", {st_mode=S_IFDIR|0770, st_size=0, ...}) = 0 select(0, NULL, NULL, NULL, {0, 1000}) = 0 (Timeout) write(2, "svn: Can't set permissions on 's"..., 82svn: Can't set permissions on 'sbin/.svn/tempfile.2.tmp': Operation not permitted) = 82 close(3) = 0 So, the error occurred when svn chmod on some tmp files. But this is disallowed in the TrueCrypt volumes, and it's just unnecessary. Can I bypass the chmod lib calls when launch svn on TrueCrypt volumes?

    Read the article

  • Getting into driver development for linux [closed]

    - by user1103966
    Right now, I've been learning about writing device-drivers for linux 3.2 kernel for about 2 months. So far I have been able program simple char drivers that only read and write to a fictitious dev structure like a file, but now I'm moving to more advance concepts. The new material I've learned about includes I/O port manipulation, memory management, and interrupts. I feel that I have a basic understanding of overall driver operation but, there is still so much that I don't know. My question is this, given that I have the basic theory of how to write a dev-driver for a piece of hardware ... how long would it take to actually develop the skills of writing actual software that companies would want to employ? I plan on getting involved in an open-source project and building a portfolio. Also what type of beginner drivers could I write for hardware that would best help me develop my skills? I was thinking that taking on a project where I design my own key logger would easy and a good assignment to help me understand how IO ports and interrupts are used. I may want to eventually specialize in writing software for video cards or network devices though these devices seem beyond my understanding at the moment. Thanks for any help

    Read the article

  • Roundcube can't connect to PostgreSQL database

    - by kenny.r
    I'm trying to install Roundcube on a CentOS 5.5 server, with a PostgreSQL 8.1.22 database. The first page of the installer script, that checks for the presence of php libraries and such, gives me green OKs across the board. I even went out of my way to install the optional ones. Page two generates me two configuration files (main.inc.php and db.inc.php) which I put into place. Page three is where things go wrong: Check DB config DSN (write): NOT OK(MDB2 Error: connect failed) Make sure that the configured database exists and that the user has write privileges DSN: pgsql://roundcube:password@localhost/roundcubemail The info you see there (user roundcube, password password, server localhost and database roundcubemail) is all correct. The database roundcubemail belongs to the user roundcube and it has write permissions. I have no clue why it can't connect to that database. I'm managing it with phpPgAdmin, which is running on the very same Apache, on the same server!

    Read the article

  • Tips for debugging Samba performance?

    - by j-g-faustus
    Samba gives me 24 MB/s read and 44 MB/s write, while ftp gives 97 and 112 MB/s under the same circumstances. The documentation says that Generally, you should find that Samba performs similarly to ftp at raw transfer speed. In my case it clearly doesn't. Where can I find tips on how to debug Samba performance? Or alternatively tips for replacing Samba with something else? (I can't use ftp, unfortunately, as I need something that can be used with rsync/rsnapshot.) More details: Both computers are running Ubuntu 10.10 (using Samba because I have a Mac as well) The Samba share is on a local home network, mounted as $ mount ... //server.local/share/ on /mnt/share type cifs (rw,mand) Samba performance was tested by copying (cp) a single file of ~4GB to and from the share, using time for timing and calculating transfer speed by hand. ftp performance are the numbers from the ftp client for get/put of the same file. iperf gives network speed ~900 Mbits/s bonnie++ gives disk speeds 200 MB/s on both sides for block reads as well as block writes Tried changing the parameters suggested in the performance tuning HOWTO (read/write raw, read size, socket options), most of them made little to no difference. (The one that made a difference caused write speed to drop 50%.)

    Read the article

< Previous Page | 146 147 148 149 150 151 152 153 154 155 156 157  | Next Page >