Search Results

Search found 4620 results on 185 pages for 'serial over lan'.

Page 153/185 | < Previous Page | 149 150 151 152 153 154 155 156 157 158 159 160  | Next Page >

  • Need solution for Network/Servers.

    - by rehanplus
    Dear All, Please help me. I just joined a new Hospital and want some help managing my network. There are some requirements: Current Network: There is a D.S.L connection and that is terminated on a LINUX proxy and then connected to D-Link layer 2 switches and then providing internet to more then 200 PC's (Would be increasing to 1500 in couple of months). D-Link switches are not configured yet. Also there is one Database server Report server and an application server. In near Future Application should be accessed by local users as well as remote users from internet via our web server. We do have a sharing server and all these servers databases and PC's are on single sub net. Required Network: All i do want is to secure my network from outside access and just allowing specific users via web application and they will be submitting there record for patient card and appointment facility by means of application and entering there record (on our database) but not violating our network resources. Secondly in house users also need to access the same application and also internet but they must have some unique identity and rights (i.e. Finance lab dept. peoples do have limited access to that application). Notes: Should i create V LAN or break sub nets. Having a firewall will solve my issues? is a router needed on these type of scenario's. Currently all the access are restricted from Linux Proxy. Thanks.

    Read the article

  • How to setup IIS 7.5 Reverse Proxy for quite a few internal servers - Server Farm?

    - by Tim Murphree
    I have tried for a few days, but I'm lost. Here's what I'm trying to do: I want to setup an IIS 7.5 as a Reverse Proxy for about 30 internal HTTP servers, located on my internal LAN. Everything is running on port 80. The internal servers are really IP based webcams. Here is scenario: www.mycamserver.com/cam1 192.168.1.101 www.mycamserver.com/cam2 192.168.1.102 and so on, until.. www.mycamserver.com/cam30 192.168.1.130 I have installed ARR and URL Rewrite. So far, I have managed, at one time, to seem to forward an incoming URL to an internal server, but the page would not fully load (error 404). Also, I setup a Server Farm, but it seems all traffic is now set to the first node on the Server Farm (192.168.1.101). However, at least the page loads and runs correctly. I simply want to do an exact match, for example, "cam14", and reverse-proxy / rewrite to a corresponding internal server address - "192.168.1.114".

    Read the article

  • Y560 Lenovo IdeaPad bandwidth issue

    - by Vlakarados
    I have a Y560 Lenovo IdeaPad, my config: i7 740QM, 4GB RAM, RADEON HD 6570m/5700 1024MB and my network adapter is Intel WIFI Link 5150. The laptop is 2 years old and the problem I'm about to describe is present from the first day. As may be seen here, the receive bandwidth should be up to 300 Mbps, but the maximum download speed from LAN and using torrents is about 2.4MB/s. My internet connection is 100Mbps and other laptops in my house have the appropriate download speed - up to 12MB/s, I have tested at my friends house and at my job, the speed remains the same. I have tried all possible configurations I could think of in network settings - nothing helps. I use Windows 7 and I have had installed different versions (Ultimate, Professional, Home, OEM Home, 64 and 32 bit versions). Some time ago I searched for the problem and found one or two threads that had the same problem and there were something said about a limitation in firmware that some experienced users have managed to bypass. Updating drivers didn't help me either. Is there any reliable way to fix this?

    Read the article

  • Configuring two subnets with two NICS. Access from a NAS to the internet

    - by archipestre
    I am having trouble configuring my NAS. I have a DSL router with WIFI (192.168.1.1) in my flatmates room. In my room I have a server with two NICS: 1) wlan0 (192.168.1.2) that connects to the DSL router via wireless 2) em1 (192.168.0.1) that connects to the NAS (192.168.0.20) with a crossover cable. I have Fedora 17 and I have enable packet forwarding. My IP configuration is as follows: WLAN0 inet 192.168.0.1 netmask 255.255.255.0 broadcast 192.168.0.255 EM1 inet 192.168.1.2 netmask 255.255.255.0 broadcast 192.168.1.255 My routing table looks like: Destination Gateway G enmask Flags Metric Ref Use Iface 0.0.0.0 192.168.1.1 0.0.0.0 UG 0 0 0 wlan0 192.168.0.0 0.0.0.0 255.255.255.0 U 0 0 0 em1 192.168.1.0 0.0.0.0 255.255.255.0 U 0 0 0 wlan0 I have enable a static route in the DSL server: Status Network Destination Subnet Mask Interface Gateway Remove Edit Active 192.168.0.0 255.255.255.0 LAN 192.168.1.2 From my server I can ping the DSL router and the NAS. From the NAS I can ping both NICS of the server. However the NAS is unable to ping the DSL router or any address in the Internet. Any idea of what is wrong. Thank you in advance

    Read the article

  • Diagnosing PC crashes (most often while using shared folders or torrents)

    - by Dyppl
    For the last few weeks my PC (pretty old P4 with WinXP SP3) has been crashing randomly. It just suddenly reboots instanteneously. It feels hardware-related but I wasn't able to determine wether it's software or hardware that causes it. I did notice a pattern though: it's more likely to crash when I copy a lot of files over network or have uTorrent running, but sometimes it crashes when I am not doing anything with it. Copying files from it over network causes it to crash in 1 to 10 minutes almost every time. Using torrents causes it to crash every 1-3 hours. With neither or that on it crashes every 24 hours or so. I ruled out the following probable causes: PSU (I bought a new one and turned off most of the drives so the power is sufficient 100%) Bad HDD or interface cable on my SATA disk from which I was originally copying the data over network (bought new SATA cable and later yanked out the HDD completely, PC still crashes without it) Video adapter (AGP slot is now empty, using the onboard VGA at the moment) Network adapter (removed it from PCI, using onboard LAN) CPU (I think: I changed the termopaste and it's temperature is below 50C) RAM (I think: I ran Memtest86 and it didn't show any errors) At the moment I only have only one system HDD and DVD drives, a mouse and a keyboard plugged in. The fact that it crashes most often when I use network extensively makes me think that maybe it's software related (I removed the network adapter from PCI and now am using an onboard one, so network hardware is unlikely to cause problems). I am now pondering system reinstall but it's not a pleasant solution so I decided to ask wether there are better ideas first. If someone can share a good diagnostic tool it would be great because I didn't find anything good. Thanks in advance, I hope that "help to diagnose" questions aren't entirely banned here. EDIT: Motherboard is actually ~4 years old as I replaced it back in 2007

    Read the article

  • Is there a way to measure wifi traffic on a network from a client?

    - by millimoose
    Is there some way (preferrably one that comes with an existing tool) to measure the traffic going through the whole WiFi network from a computer connected to it? (That is, not from the AP or something between the modem and AP.) My situation is this: a few months back, the internet connection at my parent's place got really sluggish and laggy. (Lag spikes that cause page loads to time out etc, connections plain getting lost and dropping packets forever.) It's impossible to get mom's husband to do anything about this because he brushes this off with something like "just tell your sister to turn off torrents". Unfortunately the WiFi router's firmware doesn't do traffic logging. I'm not going to risk bricking it to put WRT on it; nor am I keen on rewiring the network to add a proxy to analyse the traffic. (I'm one of those people that make computers break just by looking at them, except machines I own.) I'd like to be able to find out roughly how much data is going over the air here while all the LAN wires are out of the router, all the computers accused of torrenting are off, etc. The idea is to either show that: Even if everything but my macbook is turned off, something is congesting the network. The husband is a systems developer and has a whole lot of mysterious hardware that's not to be touched around, one of them might be culprit. There is barely any traffic on the network, but the internet is still sluggish. Meaning this is likely a problem the ISP should solve. (Some hardware of theirs being glitchy, someone on an aggregated line hogging it constantly...) The network is encrypted, but I can temporarily set it to open for the sake of finding this out. So, in conclusion? Can this be done? Or is there some alternative way I could try to diagnose the problem?

    Read the article

  • How good is Dotfuscator Community Edition? What is "good enough obfuscator"?

    - by zendar
    I plan to release one small, low priced utility. Since this is more hobby than business, I planned to use Dotfuscator Community Edition that is shipped with VS2008. How good is it? I could also use definition of "good enough obfuscator" - what features are missing from Dotfuscator Community Edition to make it good enough. Edit: I checked pricing on number of commercial obfuscators and they cost a lot. Is it worth it? Are commercial versions that much better protecting from reverse engineering? I'm not very afraid of my application being cracked (it will be disappointing if application is so bad that no one is interested in cracking it). It's not heavily protected anyway, not overly complex serial key and licence checks on few places in code. It just bugs me that without obfuscation, somebody can easily get source code, rebrand it and sell it as its own. Does this happens a lot? Edit 2: Can somebody recommend commercial obfuscator. I found lots of them, all of them are expensive, some even don't have price listed on web site. Feature wise, all products seem more or less similar. What is minimal set of features obfuscator should have?

    Read the article

  • ORA-03113 in code. In addition, TNS-12535 and ORA-03137 in alert file

    - by user1348107
    I've got an exception that contain ORA-03113: (SiPPSS.GetPrintWorkDirectDetail) - ERR:ORA-03113: end-of-file on communication channel Process ID: 7448 Session ID: 30 Serial number: 9802 ?????:12110937 ????:T855 Oracle.DataAccess.Client.OracleException ORA-03113: end-of-file on communication channel Process ID: 7448 Session ID: 30 Serial number: 9802 ?? Oracle.DataAccess.Client.OracleException.HandleErrorHelper(Int32 errCode, OracleConnection conn, IntPtr opsErrCtx, OpoSqlValCtx* pOpoSqlValCtx, Object src, String procedure, Boolean bCheck) ?? Oracle.DataAccess.Client.OracleException.HandleError(Int32 errCode, OracleConnection conn, String procedure, IntPtr opsErrCtx, OpoSqlValCtx* pOpoSqlValCtx, Object src, Boolean bCheck) ?? Oracle.DataAccess.Client.OracleCommand.ExecuteReader(Boolean requery, Boolean fillRequest, CommandBehavior behavior) ?? Oracle.DataAccess.Client.OracleDataAdapter.Fill(DataTable[] dataTables, Int32 startRecord, Int32 maxRecords, IDbCommand command, CommandBehavior behavior) ?? System.Data.Common.DbDataAdapter.Fill(DataTable dataTable) ?? SiPPSS.VSireiMeisaiDsTableAdapters.V_SIREI_MEISAITableAdapter.FillByRunningNoAndProcNo(V_SIREI_MEISAIDataTable dataTable, String RUNNING_NO, String PROC_NO) ?? C:\SVM\trunk\SiPPSSServer\Server\Dao\View\VSireiMeisaiDs.Designer.vb:? 386 ?? SiPPSS.GetPrintWorkDirectDetail.Execute(BLogicParam param) ?? C:\SVM\trunk\SiPPSSServer\Server\BLogic\Screen\Printing\Rprt0701\GetPrintWorkDirectDetail.vb:? 105 In this case, the oracle alert log as beblow: Fatal NI connect error 12170. VERSION INFORMATION: TNS for 64-bit Windows: Version 11.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Windows NT TCP/IP NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Time: 01-11?-2012 13:50:45 Tracing not turned on. Tns error struct: ns main err code: 12535 TNS-12535: TNS: ??????·???????? ns secondary err code: 12560 nt main err code: 505 TNS-00505: ??????????? nt secondary err code: 60 nt OS err code: 0 Client address: (ADDRESS=(PROTOCOL=tcp)(HOST=10.41.102.53)(PORT=1794)) Thu Nov 01 13:54:17 2012 Thread 1 cannot allocate new log, sequence 1880 Private strand flush not complete Current log# 1 seq# 1879 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1880 (LGWR switch) Current log# 2 seq# 1880 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 13:54:21 2012 Archived Log entry 1118 added for thread 1 sequence 1879 ID 0xe48db805 dest 1: Thu Nov 01 14:40:12 2012 Thread 1 cannot allocate new log, sequence 1881 Private strand flush not complete Current log# 2 seq# 1880 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1881 (LGWR switch) Current log# 3 seq# 1881 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 14:40:16 2012 Archived Log entry 1119 added for thread 1 sequence 1880 ID 0xe48db805 dest 1: Thu Nov 01 15:27:42 2012 Thread 1 cannot allocate new log, sequence 1882 Private strand flush not complete Current log# 3 seq# 1881 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1882 (LGWR switch) Current log# 1 seq# 1882 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 15:27:46 2012 Archived Log entry 1120 added for thread 1 sequence 1881 ID 0xe48db805 dest 1: Thu Nov 01 16:23:48 2012 Thread 1 cannot allocate new log, sequence 1883 Private strand flush not complete Current log# 1 seq# 1882 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1883 (LGWR switch) Current log# 2 seq# 1883 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 16:23:52 2012 Archived Log entry 1121 added for thread 1 sequence 1882 ID 0xe48db805 dest 1: Thu Nov 01 17:05:50 2012 Thread 1 cannot allocate new log, sequence 1884 Private strand flush not complete Current log# 2 seq# 1883 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1884 (LGWR switch) Current log# 3 seq# 1884 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 17:05:55 2012 Archived Log entry 1122 added for thread 1 sequence 1883 ID 0xe48db805 dest 1: Thu Nov 01 17:26:52 2012 Fatal NI connect error 12170. VERSION INFORMATION: TNS for 64-bit Windows: Version 11.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Windows NT TCP/IP NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Time: 01-11?-2012 17:26:52 Tracing not turned on. Tns error struct: ns main err code: 12535 TNS-12535: TNS: ??????·???????? ns secondary err code: 12560 nt main err code: 505 TNS-00505: ??????????? nt secondary err code: 60 nt OS err code: 0 Client address: (ADDRESS=(PROTOCOL=tcp)(HOST=10.41.102.62)(PORT=1286)) Thu Nov 01 17:27:16 2012 Fatal NI connect error 12170. VERSION INFORMATION: TNS for 64-bit Windows: Version 11.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Windows NT TCP/IP NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Time: 01-11?-2012 17:27:16 Tracing not turned on. Tns error struct: ns main err code: 12535 TNS-12535: TNS: ??????·???????? ns secondary err code: 12560 nt main err code: 505 TNS-00505: ??????????? nt secondary err code: 60 nt OS err code: 0 Client address: (ADDRESS=(PROTOCOL=tcp)(HOST=10.41.102.62)(PORT=1285)) Thu Nov 01 18:08:39 2012 Thread 1 advanced to log sequence 1885 (LGWR switch) Current log# 1 seq# 1885 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 18:08:40 2012 Archived Log entry 1123 added for thread 1 sequence 1884 ID 0xe48db805 dest 1: Thu Nov 01 19:33:21 2012 Thread 1 cannot allocate new log, sequence 1886 Private strand flush not complete Current log# 1 seq# 1885 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1886 (LGWR switch) Current log# 2 seq# 1886 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 19:33:25 2012 Archived Log entry 1124 added for thread 1 sequence 1885 ID 0xe48db805 dest 1: Thu Nov 01 20:32:25 2012 Thread 1 cannot allocate new log, sequence 1887 Private strand flush not complete Current log# 2 seq# 1886 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1887 (LGWR switch) Current log# 3 seq# 1887 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 20:32:29 2012 Archived Log entry 1125 added for thread 1 sequence 1886 ID 0xe48db805 dest 1: Thu Nov 01 21:13:07 2012 Thread 1 advanced to log sequence 1888 (LGWR switch) Current log# 1 seq# 1888 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 21:13:08 2012 Archived Log entry 1126 added for thread 1 sequence 1887 ID 0xe48db805 dest 1: Thu Nov 01 22:00:00 2012 Setting Resource Manager plan SCHEDULER[0x3006]:DEFAULT_MAINTENANCE_PLAN via scheduler window Setting Resource Manager plan DEFAULT_MAINTENANCE_PLAN via parameter Thu Nov 01 22:00:00 2012 Starting background process VKRM Thu Nov 01 22:00:00 2012 VKRM started with pid=32, OS id=4048 Thu Nov 01 22:00:59 2012 Thread 1 cannot allocate new log, sequence 1889 Private strand flush not complete Current log# 1 seq# 1888 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1889 (LGWR switch) Current log# 2 seq# 1889 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 22:01:03 2012 Archived Log entry 1127 added for thread 1 sequence 1888 ID 0xe48db805 dest 1: Thu Nov 01 22:32:36 2012 Thread 1 advanced to log sequence 1890 (LGWR switch) Current log# 3 seq# 1890 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 22:32:37 2012 Archived Log entry 1128 added for thread 1 sequence 1889 ID 0xe48db805 dest 1: Thu Nov 01 22:33:18 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_11884.trc (incident=101313): ORA-03137: TTC protocol internal error : [12333] [8] [49] [50] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101313\siporex_ora_11884_i101313.trc Thu Nov 01 22:33:21 2012 Trace dumping is performing id=[cdmp_20121101223321] Thu Nov 01 22:40:43 2012 Thread 1 cannot allocate new log, sequence 1891 Private strand flush not complete Current log# 3 seq# 1890 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1891 (LGWR switch) Current log# 1 seq# 1891 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 22:40:47 2012 Archived Log entry 1129 added for thread 1 sequence 1890 ID 0xe48db805 dest 1: Thu Nov 01 23:47:30 2012 Thread 1 cannot allocate new log, sequence 1892 Private strand flush not complete Current log# 1 seq# 1891 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1892 (LGWR switch) Current log# 2 seq# 1892 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 23:47:34 2012 Archived Log entry 1130 added for thread 1 sequence 1891 ID 0xe48db805 dest 1: Fri Nov 02 00:49:31 2012 Thread 1 cannot allocate new log, sequence 1893 Private strand flush not complete Current log# 2 seq# 1892 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1893 (LGWR switch) Current log# 3 seq# 1893 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 00:49:35 2012 Archived Log entry 1131 added for thread 1 sequence 1892 ID 0xe48db805 dest 1: Fri Nov 02 01:43:12 2012 Thread 1 cannot allocate new log, sequence 1894 Private strand flush not complete Current log# 3 seq# 1893 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1894 (LGWR switch) Current log# 1 seq# 1894 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 01:43:17 2012 Archived Log entry 1132 added for thread 1 sequence 1893 ID 0xe48db805 dest 1: Fri Nov 02 01:52:51 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_6124.trc (incident=101273): ORA-03137: TTC protocol internal error : [12333] [4] [80] [82] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101273\siporex_ora_6124_i101273.trc Fri Nov 02 01:52:54 2012 Trace dumping is performing id=[cdmp_20121102015254] Fri Nov 02 02:00:00 2012 Clearing Resource Manager plan via parameter Fri Nov 02 02:43:37 2012 Thread 1 cannot allocate new log, sequence 1895 Private strand flush not complete Current log# 1 seq# 1894 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1895 (LGWR switch) Current log# 2 seq# 1895 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 02:43:41 2012 Archived Log entry 1133 added for thread 1 sequence 1894 ID 0xe48db805 dest 1: Fri Nov 02 04:46:18 2012 Thread 1 cannot allocate new log, sequence 1896 Private strand flush not complete Current log# 2 seq# 1895 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1896 (LGWR switch) Current log# 3 seq# 1896 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 04:46:22 2012 Archived Log entry 1134 added for thread 1 sequence 1895 ID 0xe48db805 dest 1: Fri Nov 02 04:51:41 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_4048.trc (incident=101425): ORA-03137: TTC protocol internal error : [12333] [4] [67] [85] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101425\siporex_ora_4048_i101425.trc Fri Nov 02 04:51:44 2012 Trace dumping is performing id=[cdmp_20121102045144] Fri Nov 02 05:54:44 2012 Thread 1 cannot allocate new log, sequence 1897 Private strand flush not complete Current log# 3 seq# 1896 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1897 (LGWR switch) Current log# 1 seq# 1897 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 05:54:48 2012 Archived Log entry 1135 added for thread 1 sequence 1896 ID 0xe48db805 dest 1: Fri Nov 02 07:00:34 2012 Thread 1 cannot allocate new log, sequence 1898 Private strand flush not complete Current log# 1 seq# 1897 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1898 (LGWR switch) Current log# 2 seq# 1898 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 07:00:38 2012 Archived Log entry 1136 added for thread 1 sequence 1897 ID 0xe48db805 dest 1: Fri Nov 02 08:32:41 2012 Thread 1 cannot allocate new log, sequence 1899 Private strand flush not complete Current log# 2 seq# 1898 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1899 (LGWR switch) Current log# 3 seq# 1899 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 08:32:45 2012 Archived Log entry 1137 added for thread 1 sequence 1898 ID 0xe48db805 dest 1: Fri Nov 02 09:48:57 2012 Thread 1 advanced to log sequence 1900 (LGWR switch) Current log# 1 seq# 1900 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 09:48:58 2012 Archived Log entry 1138 added for thread 1 sequence 1899 ID 0xe48db805 dest 1: Fri Nov 02 10:18:15 2012 Thread 1 cannot allocate new log, sequence 1901 Private strand flush not complete Current log# 1 seq# 1900 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1901 (LGWR switch) Current log# 2 seq# 1901 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 10:18:19 2012 Archived Log entry 1139 added for thread 1 sequence 1900 ID 0xe48db805 dest 1: Fri Nov 02 10:22:58 2012 Thread 1 cannot allocate new log, sequence 1902 Private strand flush not complete Current log# 2 seq# 1901 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1902 (LGWR switch) Current log# 3 seq# 1902 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 10:23:02 2012 Archived Log entry 1140 added for thread 1 sequence 1901 ID 0xe48db805 dest 1: Fri Nov 02 10:27:38 2012 Thread 1 cannot allocate new log, sequence 1903 Checkpoint not complete Current log# 3 seq# 1902 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 cannot allocate new log, sequence 1903 Private strand flush not complete Current log# 3 seq# 1902 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1903 (LGWR switch) Current log# 1 seq# 1903 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 10:27:45 2012 Archived Log entry 1141 added for thread 1 sequence 1902 ID 0xe48db805 dest 1: Fri Nov 02 10:32:27 2012 Thread 1 cannot allocate new log, sequence 1904 Checkpoint not complete Current log# 1 seq# 1903 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 cannot allocate new log, sequence 1904 Private strand flush not complete Current log# 1 seq# 1903 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1904 (LGWR switch) Current log# 2 seq# 1904 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 10:32:34 2012 Archived Log entry 1142 added for thread 1 sequence 1903 ID 0xe48db805 dest 1: Fri Nov 02 10:35:42 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_15856.trc (incident=101353): ORA-03137: TTC protocol internal error : [12333] [8] [49] [50] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101353\siporex_ora_15856_i101353.trc Fri Nov 02 10:35:44 2012 Trace dumping is performing id=[cdmp_20121102103544] I don't know main reason of this issue as well as how to fixing it. Please help me.

    Read the article

  • C#: Regex to extract portions of file name

    - by jakesankey
    I have text files formatted as such: R156484COMP_004A7001_20100104_065119.txt I need to consistently extract the R****COMP, the 004A7001 number, 20100104 (date), and don't care about the 065119 number. the problem is that not ALL of the files being parsed have the exact naming convention. some may be like this: R168166CRIT_156B2075_SU2_20091223_123456.txt or R285476COMP_SU1_125A6025_20100407_123456.txt So how could I use regex instead of split to ensure I am always getting that serial (ex. 004A7001), the date (ex. 20100104), and the R****COMP (or CRIT)??? Here is what I do now but it only gets the files formatted like my first example. if (file.Count(c => c == '_') != 3) continue; and further down in the code I have: string RNumber = Path.GetFileNameWithoutExtension(file); string RNumberE = RNumber.Split('_')[0]; string RNumberD = RNumber.Split('_')[1]; string RNumberDate = RNumber.Split('_')[2]; DateTime dateTime = DateTime.ParseExact(RNumberDate, "yyyyMMdd", Thread.CurrentThread.CurrentCulture); string cmmDate = dateTime.ToString("dd-MMM-yyyy");

    Read the article

  • Regarding: PKCS7, X509 and DER

    - by Sid
    Hi, I am novice to the "World of cryptography". I started working with OPENSSL. I need some information and basically I do have some doubts. I have a DER format file. I read the file using following command, "openssl x509 -inform DER -in filename.der -text" I got what I supposed to be. Following things I wanted to know: 1. What is the difference between PKCS7, DER and X509 ? (My understanding is, DER is format, X509 is certificate, and PKCS7 is the standard) I wrote a test file which accepts the DER file and outputs the version, serial number, Subject, Validity date before and Validity date after, But I am unable to get certificate verified. Following is the API Used. int i = X509_verify(X509 *x509 , X509_get_pubkey(X509 *x509)); But 'i' value is 'i' < 0(zero) This is why I am getting "Signature verification problems". How to overcome this? In My test file I am unable to read the "Signature Algorithm", "Subject Public Key Info", "X509v3 extensions" and "-----BEGIN CERTIFICATE-----" to "-----END CERTIFICATE-----" Please give some inputs. Thanks in Advance. openSid

    Read the article

  • LINQ2SQL - Binding result to a grid - want changes to be reflected without re-binding?

    - by Isaac
    Hello, I have a grid (DevExpress XtraGrid, if that matters) which is bound to a LINQ to SQL Entity property. gridItems.DataSource = purchaseOrder.PendingItemsGrouped; Well, the grid is being displayed properly,and I can see the purchase items that are pending. The problem arises when purchaseOrder.PendingItemsGrouped gets changed ... once that happens, the grid does not reflect the changes. The exact procedure is as following: The user selects a row from the grid, inserts a serial number on a specific textbox, and then hits enter effectively receiving this item from the purchase order, and inserting it into stock. inventoryWorker.AddItemToStock( userSelectedItem, serialNumber ); The item gets properly inserted to the inventory, but the grid still shows the item as if it is still awaiting it to be received. How do I solve this problem? Do I really need to re-bind the grid so the changes can be reflected? I even tried instead of: gridItems.DataSource = ...; This: gridItems.DataBindings.Add( new Binding( "DataSource", purchase, "PendingItemsGrouped" ) ); But couldn't solve the problem. Thank you very much for your time, Isaac. OBS: Re-Binding the Grid works, but my question is ... is that even the proper way of doing things? I feel like I'm miles off the right track.

    Read the article

  • Opened SerialPort crashes C# application

    - by Stefan Teitge
    The computer is connected to measuring device via a physical COM1. I have simple form where I open a serial port, tell the device that I'm alive and occasionally the device sends data. (every some minutes) Thread _readThread = new Thread(Read); SerialPort _serialPort = new SerialPort("COM1", 9600); _serialPort.Parity = Parity.None; _serialPort.DataBits = 8; _serialPort.StopBits = StopBits.One; _serialPort.Handshake = Handshake.None; _serialPort.DtrEnable = true; _serialPort.Open(); _readThread.Start(); _serialPort.Write("#listening"); The read function (which works): public void Read() { string message = _serialPort.ReadLine(); } After approximately one minute the application crashes (even while debugging). It reports an ObjectDisposedException (for the underlying stream?). The message tells that the SafeHandle was closed. Stack strace is below: at Microsoft.Win32.UnsafeNativeMethods.GetOverlappedResult(SafeFileHandle hFile, NativeOverlapped lpOverlapped, Int32& lpNumberOfBytesTransferred, Boolean bWait) at System.IO.Ports.SerialStream.EventLoopRunner.WaitForCommEvent() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart()* Any ideas? The problem is reported widely but usually involve the device beeing physically detached from the PC.

    Read the article

  • PackageMaker install script for rxtx

    - by vinzenzweber
    I am using PackageMaker to create an installer for my application. During installation I need to run a bash script to properly install rxtx, a JNI library for serial port communication. This library needs to have the directory /var/lock in place with user "root" and group "uucp". The installation script also needs to add the current user to the group "uucp" for the lib to be able to write to /var/lock. Now when I run my application installer the preinstall script is run as root. Therefore "whoami" returns root instead of the user who is actually running the installer. The result is that rxtx is not able to create lock files in /var/lock because the actual user was not added as a member to "uucp". How can I get the user while my script is run by the installer. Or is it better to set the permissions for /var/lock to a different group maybe? Any suggestions are welcome! !/bin/sh curruser=whoami logger "Setting permissions for /var/lock for user $curruser!" if [ ! -d /var/lock ] then logger "Creating /var/lock!" sudo mkdir /var/lock fi sudo chgrp uucp /var/lock sudo chmod 775 /var/lock MacOSX 10.5 and later use dscl if [ sudo dscl . -read /Groups/uucp GroupMembership | grep $curruser | wc -l = "0" ] then logger "Add user $curruser to /Groups/uucp!" sudo dscl . -append /Groups/uucp GroupMembership $curruser # to revert use: # sudo dscl . -delete /Groups/uucp GroupMembership $curruser else logger "GroupMembership of /var/lock not changed!" fi

    Read the article

  • Linux Kernel wait_for_completion_timeout not wakeup by complete

    - by Jun Li
    I am working on a strange issue with the i2c-omap driver. I am not sure if the problem happens at other time or not, but it happens around 5% of the time I tried to power off the system. During system power off, I write to some registers in the PMIC via I2C. In i2c-omap.c, I can see that the calling thread is waiting on wait_for_completion_timeout with a timeout value set to 1 second. And I can see the IRQ called "complete" (I added printk AFTER "complete"). However, after "complete" gets called, the wait_for_completion_timeout did not return. Instead, it takes up to 5 MINUTES before it returns. And the return value of wait_for_completion_timeout is positive indicating that there is no timeout. And the whole I2C transaction was successful. In the meantime, I can see printk messages from other drivers. And the serial console still works. It is on Android, and if I use "top" I can see system_server is taking about 95% of the CPU. Killing system_server can make the wait_for_completion_timeout return immediately. So my question is what could a user space app (system_server) do to make a kernel "wait_for_completion_timeout" not being wake up? Thanks!

    Read the article

  • Is it a good practice to suppress warnings?

    - by Chris Cooper
    Sometimes while writing Java in Eclipse, I write code that generates warnings. A common one is this, which I get when extending the Exception class: public class NumberDivideException extends Exception { public NumberDivideException() { super("Illegal complex number operation!"); } public NumberDivideException(String s) { super(s); } } // end NumberDivideException The warning: The serializable class NumberDivideException does not declare a static final serialVersionUID field of type long. I know this warning is caused by my failure to... well, it says right above. I could solve it by including the serialVersionUID, but this is a one hour tiny assignment for school; I don't plan on serializing it anytime soon... The other option, of course, is to let Eclipse add @SuppressWarnings("serial"). But every time my mouse hovers over the Suppress option, I feel a little guilty. For programming in general, is it a good habit to suppress warnings? (Also, as a side question, is adding a "generated" serialVersionUID like serialVersionUID = -1049317663306637382L; the proper way to add a serialVersionUID, or do I have to determine the number some other way?)

    Read the article

  • F# and .Net versions

    - by rwallace
    I'm writing a program in F# at the moment, which I specified in the Visual Studio project setup to target .Net 3.5, this being the highest offered, on the theory that I might as well get the best available. Then I tried just now running the compiled program on an XP box, not expecting it to work, but just to see what would happen. Unsurprisingly I just got an error message demanding an appropriate version of the framework, but surprisingly it wasn't 3.5 it demanded, but 2.0.50727. An additional puzzle is the version of MSBuild I'm using to compile the release version of the program, which I found in the framework 3.5 directory but claims to be framework 2.0 and build engine 3.5. I just guessed it was the right version of MSBuild to use because it seemed to correspond with the highest framework version F# seems to be able to target, but should I be using a different version? Anyone have any idea what's going on? C:\Windows>dir/s msbuild.exe Volume in drive C is OS Volume Serial Number is 0422-C2D0 Directory of C:\Windows\Microsoft.NET\Framework\v2.0.50727 27/07/2008 19:03 69,632 MSBuild.exe 1 File(s) 69,632 bytes Directory of C:\Windows\Microsoft.NET\Framework\v3.5 29/07/2008 23:40 91,136 MSBuild.exe 1 File(s) 91,136 bytes Directory of C:\Windows\Microsoft.NET\Framework\v4.0.30319 18/03/2010 16:47 132,944 MSBuild.exe 1 File(s) 132,944 bytes Directory of C:\Windows\winsxs\x86_msbuild_b03f5f7f11d50a3a_6.0.6000.16386_none_815e96e1b0e084be 20/10/2006 02:14 69,632 MSBuild.exe 1 File(s) 69,632 bytes Directory of C:\Windows\winsxs\x86_msbuild_b03f5f7f11d50a3a_6.0.6000.16720_none_81591d45b0e55432 27/07/2008 19:00 69,632 MSBuild.exe 1 File(s) 69,632 bytes Directory of C:\Windows\winsxs\x86_msbuild_b03f5f7f11d50a3a_6.0.6000.20883_none_6a9133e9ca879925 27/07/2008 18:55 69,632 MSBuild.exe 1 File(s) 69,632 bytes C:\Windows>cd Microsoft.NET\Framework\v3.5 C:\Windows\Microsoft.NET\Framework\v3.5>msbuild /ver Microsoft (R) Build Engine Version 3.5.30729.1 [Microsoft .NET Framework, Version 2.0.50727.3053] Copyright (C) Microsoft Corporation 2007. All rights reserved. 3.5.30729.1

    Read the article

  • Variable Scope Problem, iPhone

    - by Stumf
    Hello all, I need some help here so I will do my best to explain. I have worked on this all day and had no success (just learning!) I have: NSArray *getValue(NSString *iosearch) { ................................. ................................... \\ More code here } - (NSString *) serialnumber { NSArray *results = getValue(@"serial-number"); if (results) return [results objectAtIndex:0]; return nil; } - (NSString *) backlightlevel { NSArray *results = getValue(@"backlight-level"); if (results) return [results objectAtIndex:0]; return nil; } I have a tableView set up and want to display my array in it so I then have: - (UITableViewCell *)tableView:(UITableView *)tableView cellForRowAtIndexPath:(NSIndexPath *)indexPath {............. ......................................................... cell.text = [results objectAtIndex:indexPath.row]; // error results undeclared here return cell; } The problem is I get results undeclared as indicated above. I also can't figure how I could get serialnumber and backlightlevel to display on the click of a button or even at load. My attempts have thrown back errors like error: 'serialnumber' undeclared (first use in this function) and warnings like warning: 'return' with a value, in function returning void. Sorry for the long question! Many thanks, Stuart

    Read the article

  • Big sinatra problems

    - by Joel M.
    Hi, So I'm having huge trouble with sinatra. Here's what I have: require 'dm-core' DataMapper.setup(:default, ENV['DATABASE_URL'] || 'sqlite3://my.db') class Something include DataMapper::Resource property :id, Serial property :thing, Text property :run_in, Integer property :added_at, DateTime property :to, String def schedule cronify(self.thing+" to "+self.to, "http://url"+self.id.to_s, self.run_in) end def notify text(self.thing, self.to) end end Something.auto_upgrade! The cronify method works. I tested it in irb. Also, the schedule instance method works, I tested it in the console. However, it doesn't work in the route, even though it works in the console. post '/add' do @something = Something.create(blah) #this works fine @something.schedule #this works fine in the console; not in the route. end I've tried everything, from @something.create(blah).schedule (which also works fine in the console, but not in the route), to defining the method cronify inside the sinatra helpers, and even calling cronify directly on the route. Nothing works on the route. What am I doing wrong?

    Read the article

  • SSL certificate exception problem in Firefox

    - by Baztoune
    Hi there, and thanks in advance for your help or any tip that could get me out of here. I work on a JEE app with a JBoss server and an Apache. I'm not really familiar with SSL connections and certificates, I understand the basic, but I have to deal with it. So on my local configuration (localhost) I have my connection certificate configured on JBoss and Apache, and a USER_DEV.P12 file, which I import in my certificates in Firefox. I have the same configuration on a distant test server (test-server), and a USER_TEST.P12 which I also import in Firefox. When I access https://localhost/ or https://test-server/ Firefox asks me to add an exception, which is normal. After that, I select the appropriated user certificate, and can use my application normally. But for the second (let's say https://test-server/), Firefox rises me a sec_error_reused_issuer_and_serial error. Of course I googled it and founded the Mozilla help, So when I delete the "server" in my certificate manager, I can access again my second domain, but the same problem occurs for the first one. To shorten the problem, my 2 client/server certificate couples are OK but I can't have 2 certificate exceptions at the same time in Firefox for my 2 different servers/users, even though the names, server address, and MD5 are different. I notified the serial is the same (01), but it's working on my colleague's computer. So am I doing something wrong? Do I have to deal with it manually each time (or with Firefox profiles)? Thanks for your help. Bastien.

    Read the article

  • Looking for Hardware that will easily interface with my .NET code.

    - by SkippyFire
    I'm a .NET C# developer looking to do some hardware interfacing/programming. I just want something super simple to mess around with. I have done one of those basic stamp projects, but I want something with less electrical work. A self-contained piece of hardware would be fine. I'm not really looking to do embedded programming... but that would actually be pretty cool if something was capable of running .net code. I'm looking for something that would be easy to connect, hopefully via USB. Serial ports seems to be more hit or miss nowadays with laptops and netbooks. Something I can easily send data to, like a mini LCD, or series of LED's. Better yet would be something that provides feedback, like a temperature sensor. The best would be something more featured that I could talk to. I would be able to send data to it, and it would send back responses. Maybe something like a servo that could report it's position? Or maybe something that I could set parameters on? Any ideas? Thanks in advance!

    Read the article

  • Regex to extract portions of file name

    - by jakesankey
    I have text files formatted as such: R156484COMP_004A7001_20100104_065119.txt I need to consistently extract the R****COMP, the 004A7001 number, 20100104 (date), and don't care about the 065119 number. the problem is that not ALL of the files being parsed have the exact naming convention. some may be like this: R168166CRIT_156B2075_SU2_20091223_123456.txt or R285476COMP_SU1_125A6025_20100407_123456.txt So how could I use regex instead of split to ensure I am always getting that serial (ex. 004A7001), the date (ex. 20100104), and the R****COMP (or CRIT)??? Here is what I do now but it only gets the files formatted like my first example. if (file.Count(c => c == '_') != 3) continue; and further down in the code I have: string RNumber = Path.GetFileNameWithoutExtension(file); string RNumberE = RNumber.Split('_')[0]; string RNumberD = RNumber.Split('_')[1]; string RNumberDate = RNumber.Split('_')[2]; DateTime dateTime = DateTime.ParseExact(RNumberDate, "yyyyMMdd", Thread.CurrentThread.CurrentCulture); string cmmDate = dateTime.ToString("dd-MMM-yyyy"); UPDATE: This is now where I am at -- I get an error to parse RNumberDate to an actual date format. "Cannot implicitly convert type 'RegularExpressions.Match' to 'string' string RNumber = Path.GetFileNameWithoutExtension(file); Match RNumberE = Regex.Match(RNumber, @"^(R|L)\d{6}(COMP|CRIT|TEST|SU[1-9])(?=_)", RegexOptions.IgnoreCase); Match RNumberD = Regex.Match(RNumber, @"(?<=_)\d{3}[A-Z]\d{4}(?=_)", RegexOptions.IgnoreCase); Match RNumberDate = Regex.Match(RNumber, @"(?<=_)\d{8}(?=_)", RegexOptions.IgnoreCase); DateTime dateTime = DateTime.ParseExact(RNumberDate, "yyyyMMdd", Thread.CurrentThread.CurrentCulture); string cmmDate = dateTime.ToString("dd-MMM-yyyy")

    Read the article

  • android logging sdcard

    - by Abhi Rao
    Hello, With Android-Emulator I am not able to write/create a file on the SD Card (for logging). Here is what I have done so far - Run mksdcard 8192K C:\android-dev\emu_sdcard\emu_logFile - Create a new AVD, when assign emu_logFile to it so that when I view the AVD Details it says C:\android-dev\emu_sdcard\emu_logFile against the field "SD Card" - Here is the relevant code public class ZLogger { static PrintWriter zLogWriter = null; private static void Initialize() { try { File sdDir = Environment.getExternalStorageDirectory(); if (sdDir.canWrite()) { : File logFile = new File (sdDir, VERSION.RELEASE + "_" + ".log"); FileWriter logFileWriter = new FileWriter(logFile); zLogWriter = new PrintWriter(logFileWriter); zLogWriter.write("\n\n - " + date + " - \n"); } } catch (IOException e) { Log.e("ZLogger", "Count not write to file: " + e.getMessage()); } } sdDir.canWrite returns false - please note it not the exception from adb shell when I do ls I see sdcard as link to /mnt/sdcard. When I do ls -l /mnt here is what I see ls -l /mnt ls -l /mnt drwxr-xr-x root system 2010-12-24 03:41 asec drwx------ root root 2010-12-24 03:41 secure d--------- system system 2010-12-24 03:41 sdcard whereas if I go to the directory where I created emu_sdcard - I see a lock has been issued, as shown here C:dir android-dev\emu_sdcard Volume in drive C is Preload Volume Serial Number is A4F3-6C29 Directory of C:\android-dev\emu_sdcard 12/24/2010 03:41 AM . 12/24/2010 03:41 AM .. 12/24/2010 03:17 AM 8,388,608 emu_logFile 12/24/2010 03:41 AM emu_logFile.lock 1 File(s) 8,388,608 bytes 3 Dir(s) 50,347,704,320 bytes free I have looked at these and other SO questions Android Emulator sdcard push error: Read-only file system (2) Not able to view SDCard folder in the FileExplorer of Android Eclipse I have added the following to AndroidManifest.xml **uses-permission android:name="android.permission.WRITE_EXTERNAL_STORAGE" ** Please let me know your thoughts - what am I missing here? Why does canWrite return false? What should I do to add permissions to sdcard?

    Read the article

  • java serialization problems with different JVMs

    - by Alberto
    I am having trouble using serialization in Java. I've searched the web for a solution but haven't found an answer yet. The problem is this - I have a Java library (I have the code and I export it to an archive prior to executing the code) which I need to use with two differents JVMs. One JVM is on the server (Ubuntu, running Java(TM) JRE SE Runtime Environment (build 1.7.0_09-b05)) and the other on Android 2.3.3. I compiled the library in Java 1.6. Now, I am trying to import to the client, an object exported from the server, but I receive this error: java.io.InvalidClassException: [Lweka.classifiers.functions.MultilayerPerceptron$NeuralEnd;; Incompatible class (SUID): [Lweka.classifiers.functions.MultilayerPerceptron$NeuralEnd;: static final long serialVersionUID =-359311387972759020L; but expected [Lweka.classifiers.functions.MultilayerPerceptron$NeuralEnd;: static final long serialVersionUID =1920571045915494592L; I do have an explicit serial version UID declared on the class MultilayerPerceptron$NeuralEnd, like this: protected class NeuralEnd extends NeuralConnection { private static final long serialVersionUID = 7305185603191183338L; } Where NeuralConnection implements the java.io.Serializable interface. If I do a serialver on MultilayerPerceptron$NeuralEnd I receive the serialVersionUID which I declared. So, why have both JVMs changed this value? Can you help me? Thanks, Alberto

    Read the article

  • Automatically add links to class source files under a specified directory of another project in Visu

    - by Binary255
    I want to share some class source files between two projects in Visual Studio 2008. I can't create a project for the common parts and reference it (see my comment if you are curious to why). I've managed to share some source files, but it could be a lot more neat. I've created a test solution called Commonality. The Solution Explorer of the Commonality solution which contains project One and Two: What I like: All class files under the Common folder of project One are automatically added to project Two by linking. It's mostly the same as if I would have chosen Add / Existing Item... : Add As Link on each new class source file. It's clear that these files have been linked in. The shortcut arrow symbol is marking each file icon. What I do not like: The file and folder tree structure under Common of project One isn't included. It's all flat. The linked source files are shown under the project root of project Two. It would look much less cluttered if they were located under Common like in project One. The file tree structure of the Commonality solution which contains project One and Two: $ tree /F /A Folder PATH listing for volume Cystem Volume serial number is 0713370 1337:F6A4 C:. | Commonality.sln | +---One | | One.cs | | One.csproj | | | +---bin | | \---Debug | | One.vshost.exe | | One.vshost.exe.manifest | | | +---Common | | | Common.cs | | | CommonTwo.cs | | | | | \---SubCommon | | CommonThree.cs | | | +---obj | | \---Debug | | +---Refactor | | \---TempPE | \---Properties | AssemblyInfo.cs | \---Two | Two.cs | Two.csproj | Two.csproj.user | Two.csproj~ | +---bin | \---Debug +---obj | \---Debug | +---Refactor | \---TempPE \---Properties AssemblyInfo.cs And the relevant part of project Two's project file Two.csproj: <ItemGroup> <Compile Include="..\One\Common\**\*.cs"> </Compile> <Compile Include="Two.cs" /> <Compile Include="Properties\AssemblyInfo.cs" /> </ItemGroup> How do I address what I do not like, while keeping what I like?

    Read the article

  • some help required while working on java and cigwin together .

    - by Hippo
    Hello .. I am new to java and also cygwin . I do not have in detailed knowledge of both . I need some help.. I simple steps i will try to explain my problem. 1) I am working on tinyOS . its open source OS , used for wireless sensor networks. It provides java libraries to work on communication (PC to sensor) 2) I am working on windows xp environment through cigwin. 3) I am developing an application . THis application requires one java interface called "Serial Forwarder" , which is readily available in libraries provided. Previously i used to start this interface manually (by entering command *"java net.tinyos.sf.SerialForwarder ")*and then my application which uses this interface. But now i want to make my application independent . User need know about this background cygwin commands . 4) So in my java application i used "Runtime.getRuntime().exec( "java net.tinyos.sf.SerialForwarder)" . 5) This i neither giving any error nor starting the interface. Am I going on right way ? When i am using runtime execute command , how can i make sure that this command is called through cigwin interface ? Also .. if i want to write .bat file .. i which i can give commands which will be executed .. how can i make sure that those commands are given through cigwin .. and not through cmd.exe .. Please help . me .

    Read the article

< Previous Page | 149 150 151 152 153 154 155 156 157 158 159 160  | Next Page >