Search Results

Search found 23399 results on 936 pages for 'configuration manager'.

Page 161/936 | < Previous Page | 157 158 159 160 161 162 163 164 165 166 167 168  | Next Page >

  • How to specify allowed exceptions in WCF's configuration file?

    - by tucaz
    Hello! I´m building a set of WCF services for internal use through all our applications. For exception handling I created a default fault class so I can return treated message to the caller if its the case or a generic one when I have no clue what happened. Fault contract: [DataContract(Name = "DefaultFault", Namespace = "http://fnac.com.br/api/2010/03")] public class DefaultFault { public DefaultFault(DefaultFaultItem[] items) { if (items == null || items.Length== 0) { throw new ArgumentNullException("items"); } StringBuilder sbItems = new StringBuilder(); for (int i = 0; i Specifying that my method can throw this exception so the consuming client will be aware of it: [OperationContract(Name = "PlaceOrder")] [FaultContract(typeof(DefaultFault))] [WebInvoke(UriTemplate = "/orders", BodyStyle = WebMessageBodyStyle.Bare, ResponseFormat = WebMessageFormat.Json, RequestFormat = WebMessageFormat.Json, Method = "POST")] string PlaceOrder(Order newOrder); Most of time we will use just .NET to .NET communication with usual binds and everything works fine since we are talking the same language. However, as you can see in the service contract declaration I have a WebInvoke attribute (and a webHttp binding) in order to be able to also talk JSON since one of our apps will be built for iPhone and this guy will talk JSON. My problem is that whenever I throw a FaultException and have includeExceptionDetails="false" in the config file the calling client will get a generic HTTP error instead of my custom message. I understand that this is the correct behavior when includeExceptionDetails is turned off, but I think I saw some configuration a long time ago to allow some exceptions/faults to pass through the service boundaries. Is there such thing like this? If not, what do u suggest for my case? Thanks a LOT!

    Read the article

  • XML configuration of Zend_Form: child nodes and attributes not always equal?

    - by Cez
    A set of forms (using Zend_Form) that I have been working on were causing me some headaches trying to figure out what was wrong with my XML configuration, as I kept getting unexpected HTML output for a particular INPUT element. It was supposed to be getting a default value, but nothing appeared. It appears that the following 2 pieces of XML are not equal when used to instantiate Zend_Form: Snippet #1: <form> <elements> <test type="hidden"> <options ignore="true" value="foo"/> </test> </elements> </form> Snippet #2: <form> <elements> <test type="hidden"> <options ignore="true"> <value>foo</value> </options> </test> </elements> </form> The type of the element doesn't appear to make a difference, so it doesn't appear to be related to hidden fields. Is this expected or not?

    Read the article

  • New Solaris 11.2 beta features: SMF stencils

    - by user13366125
    As much as there is often a lot discussion about configuration items inside the SMF repository (like the hostname), it brings an important advantage: It introduces the concept of dependencies to configuration changes. What services have be restarted when i change a configuration item. Do you remember all the services that are dependent on the hostname and need a restart after changing it? SMF solves this by putting the information about dependencies into it configuration. You define it with the manifests. However, as much configuration you may put into SMF, most applications still insists to get it's configuration inside the traditional configuration files, like the resolv.conf for the resolver or the puppet.conf for Puppet. So you need a way to take the information out of the SMF repository and generate a config file with it. In the past the way to do so, was some scripting inside the start method that generated the config file before the service started. Solaris 11.2 offers a new feature in this area. It introduces a generic method to enable you to create config files from SMF properties. It's called SMF stencils. (read more)

    Read the article

  • How can I display a form for set configuration before the main form?

    - by Hamidm
    hello, in my project i have two form's(form1,form2), form1 is configuration form. i want to show Form1 and when we click Button1 then show Form2 and free(Release) Form1. how can to i do this? i use this code. but this project start and then exit automatically.A Friend said because the application message loop never start, and application terminates because main form does not exist. how i can to solve this problem? uses Unit2; {$R *.dfm} procedure TForm1.Button1Click(Sender: TObject); begin Application.CreateForm(TForm2, Form2); Release; end; /// program Project1; uses Forms, Unit1 in 'Unit1.pas' {Form1}, Unit2 in 'Unit2.pas' {Form2}; {$R *.res} begin Application.Initialize; Application.MainFormOnTaskbar := True; Form1:= TForm1.Create(Application); Application.Run; end.

    Read the article

  • Why do I get a Null Pointer Exception?

    - by Roman
    I have this code: Manager manager = new Manager("Name"); MyWindowListener windowListener = new MyWindowListener(); manager.addWindowListener(windowListener); Eclipse writes that I have a NullPointerException in the last line. What can be the reason for that. I do have constructors in the Manager and MyWindowListener. If it's important MyWindowListener implements WindowListener.

    Read the article

  • Easy Made Easier

    - by dragonfly
        How easy is it to deploy a 2 node, fully redundant Oracle RAC cluster? Not very. Unless you use an Oracle Database Appliance. The focus of this member of Oracle's Engineered Systems family is to simplify the configuration, management and maintenance throughout the life of the system, while offering pay-as-you-grow scaling. Getting a 2-node RAC cluster up and running in under 2 hours has been made possible by the Oracle Database Appliance. Don't take my word for it, just check out these blog posts from partners and end users. The Oracle Database Appliance Experience - Zip Zoom Zoom http://www.fuadarshad.com/2012/02/oracle-database-appliance-experience.html Off-the-shelf Oracle database servers http://normanweaver.wordpress.com/2011/10/10/off-the-shelf-oracle-database-servers/ Oracle Database Appliance – Deployment Steps http://marcel.vandewaters.nl/oracle/database-appliance/oracle-database-appliance-deployment-steps     See how easy it is to deploy an Oracle Database Appliance for high availability with RAC? Now for the meat of this post, which is the first in a series of posts describing tips for making the deployment of an ODA even easier. The key to the easy deployment of an Oracle Database Appliance is the Appliance Manager software, which does the actual software deployment and configuration, based on best practices. But in order for it to do that, it needs some basic information first, including system name, IP addresses, etc. That's where the Appliance Manager GUI comes in to play, taking a wizard approach to specifying the information needed.     Using the Appliance Manager GUI is pretty straight forward, stepping through several screens of information to enter data in typical wizard style. Like most configuration tasks, it helps to gather the required information before hand. But before you rush out to a committee meeting on what to use for host names, and rely on whatever IP addresses might be hanging around, make sure you are familiar with some of the auto-fill defaults for the Appliance Manager. I'll step through the key screens below to highlight the results of the auto-fill capability of the Appliance Manager GUI.     Depending on which of the 2 Configuration Types (Config Type screen) you choose, you will get a slightly different set of screens. The Typical configuration assumes certain default configuration choices and has the fewest screens, where as the Custom configuration gives you the most flexibility in what you configure from the start. In the examples below, I have used the Custom config type.     One of the first items you are asked for is the System Name (System Info screen). This is used to identify the system, but also as the base for the default hostnames on following screens. In this screen shot, the System Name is "oda".     When you get to the next screen (Generic Network screen), you enter your domain name, DNS IP address(es), and NTP IP address(es). Next up is the Public Network screen, seen below, where you will see the host name fields are automatically filled in with default host names based on the System Name, in this case "oda". The System Name is also the basis for default host names for the extra ethernet ports available for configuration as part of a Custom configuration, as seen in the 2nd screen shot below (Other Network). There is no requirement to use these host names, as you can easily edit any of the host names. This does make filling in the configuration details easier and less prone to "fat fingers" if you are OK with these host names. Here is a full list of the automatically filled in host names. 1 2 1-vip 2-vip -scan 1-ilom 2-ilom 1-net1 2-net1 1-net2 2-net2 1-net3 2-net3     Another auto-fill feature of the Appliance Manager GUI follows a common practice of deploying IP Addresses for a RAC cluster in sequential order. In the screen shot below, I entered the first IP address (Node1-IP), then hit Tab to move to the next field. As a result, the next 5 IP address fields were automatically filled in with the next 5 IP addresses sequentially from the first one I entered. As with the host names, these are not required, and can be changed to whatever your IP address values are. One note of caution though, if the first IP Address field (Node1-IP) is filled out and you click in that field and back out, the following 5 IP addresses will be set to the sequential default. If you don't use the sequential IP addresses, pay attention to where you click that mouse. :-)     In the screen shot below, by entering the netmask value in the Netmask field, in this case 255.255.255.0, the gateway value was auto-filled into the Gateway field, based on the IP addresses and netmask previously entered. As always, you can change this value.     My last 2 screen shots illustrate that the same sequential IP address autofill and netmask to gateway autofill works when entering the IP configuration details for the Integrated Lights Out Manager (ILOM) for both nodes. The time these auto-fill capabilities save in entering data is nice, but from my perspective not as important as the opportunity to avoid data entry errors. In my next post in this series, I will touch on the benefit of using the network validation capability of the Appliance Manager GUI prior to deploying an Oracle Database Appliance.

    Read the article

  • iPhone doesn't save password for Cisco IPsec VPN using racoon daemon

    - by dsx
    On my Debian server I had set up racoon daemon (1:0.8.0-14) for Cisco IPSec VPN using certificates for authentication. My racoon.conf is like following: log info; path certificate "/etc/racoon/certs"; listen { isakmp $SERVER_IP_HERE [500]; isakmp_natt $SERVER_IP_HERE [4500]; } timer { natt_keepalive 10 sec; } remote anonymous { lifetime time 24 hours; proposal_check obey; passive on; exchange_mode aggressive,main; my_identifier asn1dn; peers_identifier asn1dn; verify_identifier on; certificate_type x509 "cert_name.crt" "key_name.key"; ca_type x509 "ca.crt"; mode_cfg on; verify_cert on; ike_frag on; generate_policy on; nat_traversal on; dpd_delay 20; proposal { encryption_algorithm aes; hash_algorithm sha1; authentication_method xauth_rsa_server; dh_group modp1024; } } mode_cfg { conf_source local; auth_source system; auth_throttle 3; save_passwd on; dns4 8.8.8.8; network4 $SOME_LAN_SUBNET; netmask4 255.255.255.0; pool_size 128; } sainfo anonymous { pfs_group 2; lifetime time 24 hour; encryption_algorithm aes; authentication_algorithm hmac_sha1; compression_algorithm deflate; } I'm not using PSK authentication here. Using iPhone configuration utility I had uploaded all required certificates to iPhone and set up VPN on demand. Everything works just fine except one thing: iPhone refuses to save VPN password regardless of save_passwd on; in racoon configuration file. As opposed to iPhone behaviour, Mac OS X 10.8.2 have no problems saving password. I had examined iPhone log file and found following: racoon[151] <Notice>: >>>>> phase change status = phase 1 established configd[50] <Notice>: IPSec Network Configuration started. configd[50] <Notice>: IPSec Network Configuration: INTERNAL-IP4-ADDRESS = $SUBNET_IP_HERE. configd[50] <Notice>: IPSec Network Configuration: INTERNAL-IP4-MASK = 255.255.255.0. configd[50] <Notice>: IPSec Network Configuration: SAVE-PASSWORD = 0. configd[50] <Notice>: IPSec Network Configuration: INTERNAL-IP4-DNS = 8.8.8.8. configd[50] <Notice>: IPSec Network Configuration: BANNER = . configd[50] <Notice>: IPSec Network Configuration: DEF-DOMAIN = . configd[50] <Notice>: IPSec Network Configuration: DEFAULT-ROUTE = local-address $SUBNET_IP_HERE/32. configd[50] <Notice>: IPSec Phase2 starting. configd[50] <Notice>: IPSec Network Configuration established. configd[50] <Notice>: IPSec Phase1 established. Please note IPSec Network Configuration message containing SAVE-PASSWORD = 0.. Is it a bug in racoon daemon on server, or iPhone (iOS version is 6.0.1 (10A523)) or it is me missing something? How to make iPhone remember IPSec VPN password?

    Read the article

  • What’s new in ASP.NET 4.0: Core Features

    - by Rick Strahl
    Microsoft released the .NET Runtime 4.0 and with it comes a brand spanking new version of ASP.NET – version 4.0 – which provides an incremental set of improvements to an already powerful platform. .NET 4.0 is a full release of the .NET Framework, unlike version 3.5, which was merely a set of library updates on top of the .NET Framework version 2.0. Because of this full framework revision, there has been a welcome bit of consolidation of assemblies and configuration settings. The full runtime version change to 4.0 also means that you have to explicitly pick version 4.0 of the runtime when you create a new Application Pool in IIS, unlike .NET 3.5, which actually requires version 2.0 of the runtime. In this first of two parts I'll take a look at some of the changes in the core ASP.NET runtime. In the next edition I'll go over improvements in Web Forms and Visual Studio. Core Engine Features Most of the high profile improvements in ASP.NET have to do with Web Forms, but there are a few gems in the core runtime that should make life easier for ASP.NET developers. The following list describes some of the things I've found useful among the new features. Clean web.config Files Are Back! If you've been using ASP.NET 3.5, you probably have noticed that the web.config file has turned into quite a mess of configuration settings between all the custom handler and module mappings for the various web server versions. Part of the reason for this mess is that .NET 3.5 is a collection of add-on components running on top of the .NET Runtime 2.0 and so almost all of the new features of .NET 3.5 where essentially introduced as custom modules and handlers that had to be explicitly configured in the config file. Because the core runtime didn't rev with 3.5, all those configuration options couldn't be moved up to other configuration files in the system chain. With version 4.0 a consolidation was possible, and the result is a much simpler web.config file by default. A default empty ASP.NET 4.0 Web Forms project looks like this: <?xml version="1.0"?> <configuration> <system.web> <compilation debug="true" targetFramework="4.0" /> </system.web> </configuration> Need I say more? Configuration Transformation Files to Manage Configurations and Application Packaging ASP.NET 4.0 introduces the ability to create multi-target configuration files. This means it's possible to create a single configuration file that can be transformed based on relatively simple replacement rules using a Visual Studio and WebDeploy provided XSLT syntax. The idea is that you can create a 'master' configuration file and then create customized versions of this master configuration file by applying some relatively simplistic search and replace, add or remove logic to specific elements and attributes in the original file. To give you an idea, here's the example code that Visual Studio creates for a default web.Release.config file, which replaces a connection string, removes the debug attribute and replaces the CustomErrors section: <?xml version="1.0"?> <configuration xmlns:xdt="http://schemas.microsoft.com/XML-Document-Transform"> <connectionStrings> <add name="MyDB" connectionString="Data Source=ReleaseSQLServer;Initial Catalog=MyReleaseDB;Integrated Security=True" xdt:Transform="SetAttributes" xdt:Locator="Match(name)"/> </connectionStrings> <system.web> <compilation xdt:Transform="RemoveAttributes(debug)" /> <customErrors defaultRedirect="GenericError.htm" mode="RemoteOnly" xdt:Transform="Replace"> <error statusCode="500" redirect="InternalError.htm"/> </customErrors> </system.web> </configuration> You can see the XSL transform syntax that drives this functionality. Basically, only the elements listed in the override file are matched and updated – all the rest of the original web.config file stays intact. Visual Studio 2010 supports this functionality directly in the project system so it's easy to create and maintain these customized configurations in the project tree. Once you're ready to publish your application, you can then use the Publish <yourWebApplication> option on the Build menu which allows publishing to disk, via FTP or to a Web Server using Web Deploy. You can also create a deployment package as a .zip file which can be used by the WebDeploy tool to configure and install the application. You can manually run the Web Deploy tool or use the IIS Manager to install the package on the server or other machine. You can find out more about WebDeploy and Packaging here: http://tinyurl.com/2anxcje. Improved Routing Routing provides a relatively simple way to create clean URLs with ASP.NET by associating a template URL path and routing it to a specific ASP.NET HttpHandler. Microsoft first introduced routing with ASP.NET MVC and then they integrated routing with a basic implementation in the core ASP.NET engine via a separate ASP.NET routing assembly. In ASP.NET 4.0, the process of using routing functionality gets a bit easier. First, routing is now rolled directly into System.Web, so no extra assembly reference is required in your projects to use routing. The RouteCollection class now includes a MapPageRoute() method that makes it easy to route to any ASP.NET Page requests without first having to implement an IRouteHandler implementation. It would have been nice if this could have been extended to serve *any* handler implementation, but unfortunately for anything but a Page derived handlers you still will have to implement a custom IRouteHandler implementation. ASP.NET Pages now include a RouteData collection that will contain route information. Retrieving route data is now a lot easier by simply using this.RouteData.Values["routeKey"] where the routeKey is the value specified in the route template (i.e., "users/{userId}" would use Values["userId"]). The Page class also has a GetRouteUrl() method that you can use to create URLs with route data values rather than hardcoding the URL: <%= this.GetRouteUrl("users",new { userId="ricks" }) %> You can also use the new Expression syntax using <%$RouteUrl %> to accomplish something similar, which can be easier to embed into Page or MVC View code: <a runat="server" href='<%$RouteUrl:RouteName=user, id=ricks %>'>Visit User</a> Finally, the Response object also includes a new RedirectToRoute() method to build a route url for redirection without hardcoding the URL. Response.RedirectToRoute("users", new { userId = "ricks" }); All of these routines are helpers that have been integrated into the core ASP.NET engine to make it easier to create routes and retrieve route data, which hopefully will result in more people taking advantage of routing in ASP.NET. To find out more about the routing improvements you can check out Dan Maharry's blog which has a couple of nice blog entries on this subject: http://tinyurl.com/37trutj and http://tinyurl.com/39tt5w5. Session State Improvements Session state is an often used and abused feature in ASP.NET and version 4.0 introduces a few enhancements geared towards making session state more efficient and to minimize at least some of the ill effects of overuse. The first improvement affects out of process session state, which is typically used in web farm environments or for sites that store application sensitive data that must survive AppDomain restarts (which in my opinion is just about any application). When using OutOfProc session state, ASP.NET serializes all the data in the session statebag into a blob that gets carried over the network and stored either in the State server or SQL Server via the Session provider. Version 4.0 provides some improvement in this serialization of the session data by offering an enableCompression option on the web.Config <Session> section, which forces the serialized session state to be compressed. Depending on the type of data that is being serialized, this compression can reduce the size of the data travelling over the wire by as much as a third. It works best on string data, but can also reduce the size of binary data. In addition, ASP.NET 4.0 now offers a way to programmatically turn session state on or off as part of the request processing queue. In prior versions, the only way to specify whether session state is available is by implementing a marker interface on the HTTP handler implementation. In ASP.NET 4.0, you can now turn session state on and off programmatically via HttpContext.Current.SetSessionStateBehavior() as part of the ASP.NET module pipeline processing as long as it occurs before the AquireRequestState pipeline event. Output Cache Provider Output caching in ASP.NET has been a very useful but potentially memory intensive feature. The default OutputCache mechanism works through in-memory storage that persists generated output based on various lifetime related parameters. While this works well enough for many intended scenarios, it also can quickly cause runaway memory consumption as the cache fills up and serves many variations of pages on your site. ASP.NET 4.0 introduces a provider model for the OutputCache module so it becomes possible to plug-in custom storage strategies for cached pages. One of the goals also appears to be to consolidate some of the different cache storage mechanisms used in .NET in general to a generic Windows AppFabric framework in the future, so various different mechanisms like OutputCache, the non-Page specific ASP.NET cache and possibly even session state eventually can use the same caching engine for storage of persisted data both in memory and out of process scenarios. For developers, the OutputCache provider feature means that you can now extend caching on your own by implementing a custom Cache provider based on the System.Web.Caching.OutputCacheProvider class. You can find more info on creating an Output Cache provider in Gunnar Peipman's blog at: http://tinyurl.com/2vt6g7l. Response.RedirectPermanent ASP.NET 4.0 includes features to issue a permanent redirect that issues as an HTTP 301 Moved Permanently response rather than the standard 302 Redirect respond. In pre-4.0 versions you had to manually create your permanent redirect by setting the Status and Status code properties – Response.RedirectPermanent() makes this operation more obvious and discoverable. There's also a Response.RedirectToRoutePermanent() which provides permanent redirection of route Urls. Preloading of Applications ASP.NET 4.0 provides a new feature to preload ASP.NET applications on startup, which is meant to provide a more consistent startup experience. If your application has a lengthy startup cycle it can appear very slow to serve data to clients while the application is warming up and loading initial resources. So rather than serve these startup requests slowly in ASP.NET 4.0, you can force the application to initialize itself first before even accepting requests for processing. This feature works only on IIS 7.5 (Windows 7 and Windows Server 2008 R2) and works in combination with IIS. You can set up a worker process in IIS 7.5 to always be running, which starts the Application Pool worker process immediately. ASP.NET 4.0 then allows you to specify site-specific settings by setting the serverAutoStartEnabled on a particular site along with an optional serviceAutoStartProvider class that can be used to receive "startup events" when the application starts up. This event in turn can be used to configure the application and optionally pre-load cache data and other information required by the app on startup.  The configuration settings need to be made in applicationhost.config: <sites> <site name="WebApplication2" id="1"> <application path="/" serviceAutoStartEnabled="true" serviceAutoStartProvider="PreWarmup" /> </site> </sites> <serviceAutoStartProviders> <add name="PreWarmup" type="PreWarmupProvider,MyAssembly" /> </serviceAutoStartProviders> Hooking up a warm up provider is optional so you can omit the provider definition and reference. If you do define it here's what it looks like: public class PreWarmupProvider System.Web.Hosting.IProcessHostPreloadClient { public void Preload(string[] parameters) { // initialization for app } } This code fires and while it's running, ASP.NET/IIS will hold requests from hitting the pipeline. So until this code completes the application will not start taking requests. The idea is that you can perform any pre-loading of resources and cache values so that the first request will be ready to perform at optimal performance level without lag. Runtime Performance Improvements According to Microsoft, there have also been a number of invisible performance improvements in the internals of the ASP.NET runtime that should make ASP.NET 4.0 applications run more efficiently and use less resources. These features come without any change requirements in applications and are virtually transparent, except that you get the benefits by updating to ASP.NET 4.0. Summary The core feature set changes are minimal which continues a tradition of small incremental changes to the ASP.NET runtime. ASP.NET has been proven as a solid platform and I'm actually rather happy to see that most of the effort in this release went into stability, performance and usability improvements rather than a massive amount of new features. The new functionality added in 4.0 is minimal but very useful. A lot of people are still running pure .NET 2.0 applications these days and have stayed off of .NET 3.5 for some time now. I think that version 4.0 with its full .NET runtime rev and assembly and configuration consolidation will make an attractive platform for developers to update to. If you're a Web Forms developer in particular, ASP.NET 4.0 includes a host of new features in the Web Forms engine that are significant enough to warrant a quick move to .NET 4.0. I'll cover those changes in my next column. Until then, I suggest you give ASP.NET 4.0 a spin and see for yourself how the new features can help you out. © Rick Strahl, West Wind Technologies, 2005-2010Posted in ASP.NET  

    Read the article

  • Boot From a USB Drive Even if your BIOS Won’t Let You

    - by Trevor Bekolay
    You’ve always got a trusty bootable USB flash drive with you to solve computer problems, but what if a PC’s BIOS won’t let you boot from USB? We’ll show you how to make a CD or floppy disk that will let you boot from your USB drive. This boot menu, like many created before USB drives became cheap and commonplace, does not include an option to boot from a USB drive. A piece of freeware called PLoP Boot Manager solves this problem, offering an image that can burned to a CD or put on a floppy disk, and enables you to boot to a variety of devices, including USB drives. Put PLoP on a CD PLoP comes as a zip file, which includes a variety of files. To put PLoP on a CD, you will need either plpbt.iso or plpbtnoemul.iso from that zip file. Either disc image should work on most computers, though if in doubt plpbtnoemul.iso should work “everywhere,” according to the readme included with PLoP Boot Manager. Burn plpbtnoemul.iso or plpbt.iso to a CD and then skip to the “booting PLoP Boot Manager” section. Put PLoP on a Floppy Disk If your computer is old enough to still have a floppy drive, then you will need to put the contents of the plpbt.img image file found in PLoP’s zip file on a floppy disk. To do this, we’ll use a freeware utility called RawWrite for Windows. We aren’t fortunate enough to have a floppy drive installed, but if you do it should be listed in the Floppy drive drop-down box. Select your floppy drive, then click on the “…” button and browse to plpbt.img. Press the Write button to write PLoP boot manager to your floppy disk. Booting PLoP Boot Manager To boot PLoP, you will need to have your CD or floppy drive boot with higher precedence than your hard drive. In many cases, especially with floppy disks, this is done by default. If the CD or floppy drive is not set to boot first, then you will need to access your BIOS’s boot menu, or the setup menu. The exact steps to do this vary depending on your BIOS – to get a detailed description of the process, search for your motherboard’s manual (or your laptop’s manual if you’re working with a laptop). In general, however, as the computer boots up, some important keyboard strokes are noted somewhere prominent on the screen. In our case, they are at the bottom of the screen. Press Escape to bring up the Boot Menu. Previously, we burned a CD with PLoP Boot Manager on it, so we will select the CD-ROM Drive option and hit Enter. If your BIOS does not have a Boot Menu, then you will need to access the Setup menu and change the boot order to give the floppy disk or CD-ROM Drive higher precedence than the hard drive. Usually this setting is found in the “Boot” or “Advanced” section of the Setup menu. If done correctly, PLoP Boot Manager will load up, giving a number of boot options. Highlight USB and press Enter. PLoP begins loading from the USB drive. Despite our BIOS not having the option, we’re now booting using the USB drive, which in our case holds an Ubuntu Live CD! This is a pretty geeky way to get your PC to boot from a USB…provided your computer still has a floppy drive. Of course if your BIOS won’t boot from a USB it probably has one…or you really need to update it. Download PLoP Boot Manager Download RawWrite for Windows Similar Articles Productive Geek Tips Create a Bootable Ubuntu 9.10 USB Flash DriveReinstall Ubuntu Grub Bootloader After Windows Wipes it OutCreate a Bootable Ubuntu USB Flash Drive the Easy WayBuilding a New Computer – Part 3: Setting it UpInstall Windows XP on Your Pre-Installed Windows Vista Computer TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Office 2010 reviewed in depth by Ed Bott FoxClocks adds World Times in your Statusbar (Firefox) Have Fun Editing Photo Editing with Citrify Outlook Connector Upgrade Error Gadfly is a cool Twitter/Silverlight app Enable DreamScene in Windows 7

    Read the article

  • Easy Made Easier - Networking

    - by dragonfly
        In my last post, I highlighted the feature of the Appliance Manager Configurator to auto-fill some fields based on previous field values, including host names based on System Name and sequential IP addresses from the first IP address entered. This can make configuration a little faster and a little less subject to data entry errors, particularly if you are doing the configuration on the Oracle Database Appliance itself.     The Oracle Database Appliance Appliance Manager Configurator is available for download here. But why would you download it, if it comes pre-installed on the Oracle Database Appliance? A common reason for customers interested in this new Engineered System is to get a good idea of how easy it is to configure. Beyond that, you can save the resulting configuration as a file, and use it on an Oracle Database Appliance. This allows you to verify the data entered in advance, and in the comfort of your office. In addition, the topic of this post is another strong reason to download and use the Appliance Manager Configurator prior to deploying your Oracle Database Appliance.     The most common source of hiccups in deploying an Oracle Database Appliance, based on my experiences with a variety of customers, involves the network configuration. It is during Step 11, when network validation occurs, that these come to light, which is almost half way through the 24 total steps, and can be frustrating, whether it was a typo, DNS mis-configuration or IP address already in use. This is why I recommend as a best practice taking advantage of the Appliance Manager Configurator prior to deploying an Oracle Database Appliance.     Why? Not only do you get the benefit of being able to double check your entries before you even start on the Oracle Database Appliance, you can also take advantage of the Network Validation step. This is the final step before you review all the data and can save it to a text file. It can be skipped, if you aren't ready or are not connected to the network that the Oracle Database Appliance will be on. My recommendation, though, is to run the Appliance Manager Configurator on your laptop, enter the data or re-load a previously saved file of the data, and then connect to the network that the Oracle Database Appliance will be on. Now run the Network Validation. It will check to make sure that the host names you entered are in DNS and do resolve to the IP addresses you specifiied. It will also ping the IP Addresses you specified, so that you can verify that no other machine is already using them (yes, that has happened at customer sites).     After you have completed the validation, as seen in the screen shot below, you can review the results and move on to saving your settings to a file for use on your Oracle Database Appliance, or if there are errors, you can use the Back button to return to the appropriate screen and correct the data. Once you are satisfied with the Network Validation, just check the Skip/Ignore Network Validation checkbox at the top of the screen, then click Next. Is the Network Validation in the Appliance Manager Configurator required? No, but it can save you time later. I should also note that the Network Validation screen is not part of the Appliance Manager Configurator that currently ships on the Oracle Database Appliance, so this is the easiest way to verify your network configuration.     I hope you are finding this series of posts useful. My next post will cover some aspects of the windowing environment that gets run by the 'startx' command on the Oracle Database Appliance, since this is needed to run the Appliance Manager Configurator via a direct connected monitor, keyboard and mouse, or via the ILOM. If it's been a while since you've used an OpenWindows environment, you'll want to check it out.

    Read the article

  • Unable to Mange DNS via MMC

    - by IT Helpdesk Team Manager
    When trying to access the DNS service on Microsoft Windows Server 2003 (Build 3790) domain controller/schema master via the MMC DNS snap in or locally via the DNS MMC from Administrative tools I'm getting a red "X" through the icon for the DNS Server. The inability to access DNS management via MMC happens on all domain controllers as well. We've looked at items such as the DHCP client not being started, incorrect DNS setup ( the machine points at itself and another DC ), the DNS service not running ( it is and all DNS queries via NSLOOKUP work correctly ), dslint returns the correct information and functions as expected. There is the following entry in the DNS event log: The DNS server could not initialize the remote procedure call (RPC) service. If it is not running, start the RPC service or reboot the computer. The event data is the error code. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. 0000: 0000051b dnscmd fails with RPC server unavailable yet RPC is started: C:\Documents and Settings\Administrator.DOMAIN>dnscmd /Info Info query failed status = 1722 (0x000006ba) Command failed: RPC_S_SERVER_UNAVAILABLE 1722 (000006ba) DCDIAG /TEST:DNS /V /E produces the following errors: Warning: no DNS RPC connectivity (error or non Microsoft DNS server is running) [Error details: 1753 (Type: Win32 - Description: There are no more endpoints available from the endpoint mapper.)] Warning: no DNS RPC connectivity (error or non Microsoft DNS server is running) [Error details: 1722 (Type: Win32 - Description: The RPC server is unavailable.)] The DNS server could not initialize the remote procedure call (RPC) service. If it is not running, start the RPC service or reboot the computer. The event data is the error code. A DNS query for _ldap._tcp.dc._msdcs. returns the correct results. All domain and ADS related activities are working except that I can't manage my DNS via MMC or dnscmd. Any thoughts or solutions would be greatly appreciated. EDIT: Adding Registry export per request: Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc Class Name: <NO CLASS> Last Write Time: 10/18/2012 - 2:29 PM Value 0 Name: DCOM Protocols Type: REG_MULTI_SZ Data: ncacn_ip_tcp Value 1 Name: UuidSequenceNumber Type: REG_DWORD Data: 0xb19bd0f Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc\ClientProtocols Class Name: <NO CLASS> Last Write Time: 3/9/2007 - 12:11 PM Value 0 Name: ncacn_np Type: REG_SZ Data: rpcrt4.dll Value 1 Name: ncacn_ip_tcp Type: REG_SZ Data: rpcrt4.dll Value 2 Name: ncadg_ip_udp Type: REG_SZ Data: rpcrt4.dll Value 3 Name: ncacn_http Type: REG_SZ Data: rpcrt4.dll Value 4 Name: ncacn_at_dsp Type: REG_SZ Data: rpcrt4.dll Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc\NameService Class Name: <NO CLASS> Last Write Time: 2/20/2006 - 4:48 PM Value 0 Name: DefaultSyntax Type: REG_SZ Data: 3 Value 1 Name: Endpoint Type: REG_SZ Data: \pipe\locator Value 2 Name: NetworkAddress Type: REG_SZ Data: \\. Value 3 Name: Protocol Type: REG_SZ Data: ncacn_np Value 4 Name: ServerNetworkAddress Type: REG_SZ Data: \\. Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc\NetBios Class Name: <NO CLASS> Last Write Time: 2/20/2006 - 4:48 PM Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc\RpcProxy Class Name: <NO CLASS> Last Write Time: 3/9/2007 - 12:11 PM Value 0 Name: Enabled Type: REG_DWORD Data: 0x1 Value 1 Name: ValidPorts Type: REG_SZ Data: pdc:100-5000 Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc\SecurityService Class Name: <NO CLASS> Last Write Time: 2/20/2006 - 4:48 PM Value 0 Name: 9 Type: REG_SZ Data: secur32.dll Value 1 Name: 10 Type: REG_SZ Data: secur32.dll Value 2 Name: 14 Type: REG_SZ Data: schannel.dll Value 3 Name: 16 Type: REG_SZ Data: secur32.dll Value 4 Name: 1 Type: REG_SZ Data: secur32.dll Value 5 Name: 18 Type: REG_SZ Data: secur32.dll Value 6 Name: 68 Type: REG_SZ Data: netlogon.dll

    Read the article

  • default outlook calendar update with holidays

    - by New IT Manager
    We are currently on a SBS2003 with exchange + outlook 2010 client environment. we have some developers working across 3 countries connected to the same domain however i would like all three country holidays to appear in everyone's default calendar. i did try several options synchronizing back to everyones calendar and well it was not so helpful. any thoughts would be much appreciated.. thanks in advance folds :)

    Read the article

  • Performance issues with jms and spring integration. What is wrong with the following configuration?

    - by user358448
    I have a jms producer, which generates many messages per second, which are sent to amq persistent queue and are consumed by single consumer, which needs to process them sequentially. But it seems that the producer is much faster than the consumer and i am having performance and memory problems. Messages are fetched very very slowly and the consuming seems to happen on intervals (the consumer "asks" for messages in polling fashion, which is strange?!) Basically everything happens with spring integration. Here is the configuration at the producer side. First stake messages come in stakesInMemoryChannel, from there, they are filtered throw the filteredStakesChannel and from there they are going into the jms queue (using executor so the sending will happen in separate thread) <bean id="stakesQueue" class="org.apache.activemq.command.ActiveMQQueue"> <constructor-arg name="name" value="${jms.stakes.queue.name}" /> </bean> <int:channel id="stakesInMemoryChannel" /> <int:channel id="filteredStakesChannel" > <int:dispatcher task-executor="taskExecutor"/> </int:channel> <bean id="stakeFilterService" class="cayetano.games.stake.StakeFilterService"/> <int:filter input-channel="stakesInMemoryChannel" output-channel="filteredStakesChannel" throw-exception-on-rejection="false" expression="true"/> <jms:outbound-channel-adapter channel="filteredStakesChannel" destination="stakesQueue" delivery-persistent="true" explicit-qos-enabled="true" /> <task:executor id="taskExecutor" pool-size="100" /> The other application is consuming the messages like this... The messages come in stakesInputChannel from the jms stakesQueue, after that they are routed to 2 separate channels, one persists the message and the other do some other stuff, lets call it "processing". <bean id="stakesQueue" class="org.apache.activemq.command.ActiveMQQueue"> <constructor-arg name="name" value="${jms.stakes.queue.name}" /> </bean> <jms:message-driven-channel-adapter channel="stakesInputChannel" destination="stakesQueue" acknowledge="auto" concurrent-consumers="1" max-concurrent-consumers="1" /> <int:publish-subscribe-channel id="stakesInputChannel" /> <int:channel id="persistStakesChannel" /> <int:channel id="processStakesChannel" /> <int:recipient-list-router id="customRouter" input-channel="stakesInputChannel" timeout="3000" ignore-send-failures="true" apply-sequence="true" > <int:recipient channel="persistStakesChannel"/> <int:recipient channel="processStakesChannel"/> </int:recipient-list-router> <bean id="prefetchPolicy" class="org.apache.activemq.ActiveMQPrefetchPolicy"> <property name="queuePrefetch" value="${jms.broker.prefetch.policy}" /> </bean> <bean id="connectionFactory" class="org.springframework.jms.connection.CachingConnectionFactory"> <property name="targetConnectionFactory"> <bean class="org.apache.activemq.ActiveMQConnectionFactory"> <property name="brokerURL" value="${jms.broker.url}" /> <property name="prefetchPolicy" ref="prefetchPolicy" /> <property name="optimizeAcknowledge" value="true" /> <property name="useAsyncSend" value="true" /> </bean> </property> <property name="sessionCacheSize" value="10"/> <property name="cacheProducers" value="false"/> </bean>

    Read the article

  • Is there an API to remotely read a Windows machine's audit configuration?

    - by JCCyC
    I need to know, for each subcategory, whether it'll be audited on success, on failure, both, or none. Below is an example of the information I need to collect. Can I get this through WMI? Or if not, by other means, assuming I have proper (admin) credentials to the target machine? Again, to clarify, it's not the event log I need to read, it's the logging configuration. <security_state_change>AUDIT_SUCCESS</security_state_change> <security_system_extension>AUDIT_NONE</security_system_extension> <system_integrity>AUDIT_SUCCESS_FAILURE</system_integrity> <ipsec_driver>AUDIT_NONE</ipsec_driver> <other_system_events>AUDIT_SUCCESS_FAILURE</other_system_events> <logon>AUDIT_SUCCESS</logon> <logoff>AUDIT_SUCCESS</logoff> <account_lockout>AUDIT_SUCCESS</account_lockout> <ipsec_main_mode>AUDIT_NONE</ipsec_main_mode> <ipsec_quick_mode>AUDIT_NONE</ipsec_quick_mode> <ipsec_extended_mode>AUDIT_NONE</ipsec_extended_mode> <special_logon>AUDIT_SUCCESS</special_logon> <other_logon_logoff_events>AUDIT_NONE</other_logon_logoff_events> <file_system>AUDIT_NONE</file_system> <registry>AUDIT_NONE</registry> <kernel_object>AUDIT_NONE</kernel_object> <sam>AUDIT_NONE</sam> <certification_services>AUDIT_NONE</certification_services> <application_generated>AUDIT_NONE</application_generated> <handle_manipulation>AUDIT_NONE</handle_manipulation> <file_share>AUDIT_NONE</file_share> <filtering_platform_packet_drop>AUDIT_NONE</filtering_platform_packet_drop> <filtering_platform_connection>AUDIT_NONE</filtering_platform_connection> <other_object_access_events>AUDIT_NONE</other_object_access_events> <sensitive_privilege_use>AUDIT_NONE</sensitive_privilege_use> <non_sensitive_privlege_use>AUDIT_NONE</non_sensitive_privlege_use> <other_privlege_use_events>AUDIT_NONE</other_privlege_use_events> <process_creation>AUDIT_NONE</process_creation> <process_termination>AUDIT_NONE</process_termination> <dpapi_activity>AUDIT_NONE</dpapi_activity> <rpc_events>AUDIT_NONE</rpc_events> <audit_policy_change>AUDIT_SUCCESS</audit_policy_change> <authentication_policy_change>AUDIT_SUCCESS</authentication_policy_change> <authorization_policy_change>AUDIT_NONE</authorization_policy_change> <mpssvc_rule_level_policy_change>AUDIT_NONE</mpssvc_rule_level_policy_change> <filtering_platform_policy_change>AUDIT_NONE</filtering_platform_policy_change> <other_policy_change_events>AUDIT_NONE</other_policy_change_events> <user_account_management>AUDIT_SUCCESS</user_account_management> <computer_account_management>AUDIT_NONE</computer_account_management> <security_group_management>AUDIT_SUCCESS</security_group_management> <distribution_group_management>AUDIT_NONE</distribution_group_management> <application_group_management>AUDIT_NONE</application_group_management> <other_account_management_events>AUDIT_NONE</other_account_management_events> <directory_service_access>AUDIT_NONE</directory_service_access> <directory_service_changes>AUDIT_NONE</directory_service_changes> <directory_service_replication>AUDIT_NONE</directory_service_replication> <detailed_directory_service_replication>AUDIT_NONE</detailed_directory_service_replication> <credential_validation>AUDIT_NONE</credential_validation> <kerberos_ticket_events>AUDIT_NONE</kerberos_ticket_events> <other_account_logon_events>AUDIT_NONE</other_account_logon_events>

    Read the article

  • Importing owl files

    - by Mikae Combarado
    Hello, I have a problem with importing owl files using owl api in Java. I successfully can import 2 owl files. However, a problem occurs, when I try to import 3 or more owl files that are integrated to each other. E.g. Base.owl -- base ontology Electronics.owl -- electronics ontology which imports Base.owl Telephone.owl -- telephone ontology which imports Base.owl and Electronics.owl When, I just import Base.owl and run Electronics.owl, it works smoothly. The code is given below: File fileBase = new File("filepath/Base.owl"); File fileElectronic = new File("filePath/Electronic.owl"); SimpleIRIMapper iriMapper = new SimpleIRIMapper(IRI.create("url/Base.owl"), IRI.create(fileBase)); OWLOntologyManager manager = OWLManager.createOWLOntologyManager(); manager.addIRIMapper(iriMapper); OWLOntology ont = manager.loadOntologyFromOntologyDocument(fileElectronic); However, when I want to load Telephone.owl, I just create an additional iriMapper and add it to the manager. The additional code is shown with ** : File fileBase = new File("filepath/Base.owl"); File fileElectronic = new File("filePath/Electronic.owl"); **File fileTelephone = new File("filePath/Telephone.owl");** SimpleIRIMapper iriMapper = new SimpleIRIMapper(IRI.create("url/Base.owl"), IRI.create(fileBase)); **SimpleIRIMapper iriMapper2 = new SimpleIRIMapper(IRI.create("url/Electronic.owl"), IRI.create(fileElectronic));** OWLOntologyManager manager = OWLManager.createOWLOntologyManager(); manager.addIRIMapper(iriMapper); **manager.addIRIMapper(iriMapper2);** OWLOntology ont = manager.loadOntologyFromOntologyDocument(**fileTelephone**); The code shown above gives this error : Could not load import: Import(url/Electronic.owl>) Reason: Could not loaded imported ontology: <url/Base.owl> Cause: null It would be really appreciated, if someone gives me a hand... Thanks in advance...

    Read the article

  • MySQL: Complex Join Statement involving two tables and a third correlation table

    - by Stephen
    I have two tables that were built for two disparate systems. I have records in one table (called "leads") that represent customers, and records in another table (called "manager") that are the exact same customers but "manager" uses different fields (For example, "leads" contains an email address, and "manager" contains two fields for two different emails--either of which might be the email from "leads"). So, I've created a correlation table that contains the lead_id and manager_id. currently this correlation table is empty. I'm trying to query the "leads" table to give me records that match either "manager" email field with the single "leads" email field, while at the same time ignoring fields that have already been added to the "correlated" table. (this way I can see how many leads that match have not yet been correlated.) Here's my current, invalid SQL attempt: SELECT leads.id, manager.id FROM leads, manager LEFT OUTER JOIN correlation ON correlation.lead_id = leads.id WHERE correlation.id IS NULL AND leads.project != "someproject" AND (manager.orig_email = leads.email OR manager.dest_email = leads.email) AND leads.created BETWEEN '1999-01-01 00:00:00' AND '2010-05-10 23:59:59' ORDER BY leads.created ASC; I get the error: Unknown column 'leads.id' in 'on clause' Before you wonder: there are records in the "leads" table where leads.project != "someproject" and leads.created falls between those dates. I've included those additional parameters for completeness.

    Read the article

  • Getting Started with Media Browser for Windows Media Center

    - by DigitalGeekery
    If you are a Windows Media Center user, you’ll really want to check out Media Browser. The Media Browser plug-in for Windows Media Center takes your digital media files and displays them in a visually appealing, user friendly interface, complete with images and metadata. Requirements Windows 7 or Vista Microsoft .Net 3.5 Framework  Preparing your Media Files For Media Browser to be able to automatically download images and metadata for your media libraries, your files will have to be correctly named. For example, if you have an mp4 file of the movie Batman Begins, it needs to be named Batman Begins.mp4. It cannot be Batmanbegins.mp4 or Batman-begins.mp4. Otherwise, it’s unlikely that Media Browser will display images and metadata. If you find some of your files aren’t pulling cover art or metadata, double-check the official title of the media on a site like IMBD.com. TV Show files TV show files are handled a bit differently. Every TV series in your collection must have a main folder with the show’s name and individual subfolders for each season. Here is an example of folder structure and supported naming conventions. TV Shows\South Park\Season 1\s01e01 – episode 1.mp4 TV Shows\South Park\Season 1\South Park 1×01 – episode 1.mp4 TV Shows\South Park\Season 1\101 – episode 1.mp4  Note: You need to always have a Season 1 folder even if the show only has only one season. If you have several seasons of a particular show, but don’t happen to have Season 1, simply create a blank season 1 folder. Without a season 1 folder, other seasons will not display properly. Installation and Configuration Download and run the latest Media Browser .msi file by taking the defaults. (Download link below) When you reach the final window, leave the “Configure initial settings” box checked, and click “Finish.” You may get a pop up window informing you that folder permissions are not set correctly for Media Browser. Click “Yes.” Adding Your Media The Browser Configuration Tool should have opened automatically. If not, you can open it by going to Start > All Programs > Media Browser > Media Browser Configuration Wizard. To begin adding media files, click “Add.” Browse for a folder that contains media files and click “OK.” Here we are adding a folder with a group of movie files. You can add multiple folders to each media library. For example, if you have movie files stored in 4 or 5 different folders, you can add them all under a single library in Media Browser.  To add additional folders, click the “Add” button on the right side under your currently added folder. The “Add” button to the left will add an additional Media Library, such as one for TV Shows. When you are finished, close out of the Media Browser Configuration Tool. Open Windows Media Center. You will see Media Browser tile on the main interface. Click to open it. When you initially open Media Browser, you will be prompted to run the initial configuration. Click “OK.” You will see a few general configuration options. The important option is the Metadata. Leave this option checked (it is by default) if you wish to pull images & other metadata for your media. When finished, click “Continue,” and then “OK” to restart Media Browser. When you re-enter Media Browser you’ll see your Media Categories listed below, and recently added files in the main display. Click on a Media Library to view the files.   Click “View” at the top to check out some of the different display options to choose from. Below you see can “Detail.” This presents your videos in a list to the left. When you hover over a title, the synopsis and cover art is displayed to the right. “Cover Flow” displays your titles in a right to left format with mirror cover art. “Thumb Strip” displays your titles in a strip along the bottom with a synopsis, image, and movie data above. Configurations Settings and options can be changed through the Media Browser Configuration Tool, or directly in Media Browser by clicking on the “Wrench” at the bottom right of the main Media Browser page. Certain settings may only be available in one location or the other. Some will be available in both places.   Plug-ins and Themes Media Browser features a variety of Plug-ins and Themes that can add optional customization and slick visual appeal. To install plug-ins or themes, open the Media Browser Configuration Tool. Click on the “plug-ins” tab, and then the “More Plug-ins…” button. Note: Clicking on “Advanced” at the top will reveal several additional configuration tabs. Browse the list of plug-ins on the left. When you find want you like, select it and then click “Install.” When the install is complete, you’ll see them listed under “Installed Plug-ins.” To activate any installed theme, click on the “Display” tab. Select it from the Visual Theme drop down list. Close out of the Media Browser Configuration Tool when finished. Some themes, such as the “Diamond” theme shown below, include optional views and settings which can be accessed through a configuration button at the top of the screen. Clicking on the movie gives you additional images and information such as a synopsis, runtime, IMDB rating…   … and even actors and character names.   All that’s left is to hit “Play” when you’re ready to watch.   Conclusion Media Browser is a fantastic plug-in that brings an entirely different level of media management and aesthetics to Windows Media Center. There are numerous additional customizations and configurations we have not covered here such as adding film trailers, music support, and integrating Recorded TV. Media Browser will run on both Windows 7 and Vista. Extenders are also supported but may require additional configuration. Download Media Browser Similar Articles Productive Geek Tips Using Netflix Watchnow in Windows Vista Media Center (Gmedia)Schedule Updates for Windows Media CenterIntegrate Hulu Desktop and Windows Media Center in Windows 7Add Color Coding to Windows 7 Media Center Program GuideIntegrate Boxee with Media Center in Windows 7 TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 If it were only this easy SyncToy syncs Files and Folders across Computers on a Network (or partitions on the same drive) Classic Cinema Online offers 100’s of OnDemand Movies OutSync will Sync Photos of your Friends on Facebook and Outlook Windows 7 Easter Theme YoWindoW, a real time weather screensaver

    Read the article

  • Getting started with Blocks and namespaces - Enterprise Library 5.0 Tutorial Part 2

    This is my second post in this series. In first blog post I explained how to install Enterprise Library 5.0 and provided links to various resources. Enterprise Library is divided into various blocks. Simply we can say, a block is a ready made solution for a particular common problem across various applications. So instead focusing on implementation of common problem across various applications, we can reuse these fully tested and extendable blocks to increase the productivity and also extendibility as these blocks are made with good design principles and patterns. Major blocks of Enterprise Library 5.0 are as follows.   Core infrastructure Functional Application Blocks Caching Data Exception Handling Logging Security Cryptography Validation Wiring Application Blocks Unity Policy Injection/Interception   Each block resides in its own assembly, and also some extra assemblies for common infrastructure. Assemblies are as follows. Microsoft.Practices.EnterpriseLibrary.Caching.Cryptography.dll Microsoft.Practices.EnterpriseLibrary.Caching.Database.dll Microsoft.Practices.EnterpriseLibrary.Caching.dll Microsoft.Practices.EnterpriseLibrary.Common.dll Microsoft.Practices.EnterpriseLibrary.Configuration.Design.HostAdapter.dll Microsoft.Practices.EnterpriseLibrary.Configuration.Design.HostAdapterV5.dll Microsoft.Practices.EnterpriseLibrary.Configuration.DesignTime.dll Microsoft.Practices.EnterpriseLibrary.Configuration.EnvironmentalOverrides.dll Microsoft.Practices.EnterpriseLibrary.Data.dll Microsoft.Practices.EnterpriseLibrary.Data.SqlCe.dll Microsoft.Practices.EnterpriseLibrary.ExceptionHandling.dll Microsoft.Practices.EnterpriseLibrary.ExceptionHandling.Logging.dll Microsoft.Practices.EnterpriseLibrary.ExceptionHandling.WCF.dll Microsoft.Practices.EnterpriseLibrary.Logging.Database.dll Microsoft.Practices.EnterpriseLibrary.Logging.dll Microsoft.Practices.EnterpriseLibrary.PolicyInjection.dll Microsoft.Practices.EnterpriseLibrary.Security.Cache.CachingStore.dll Microsoft.Practices.EnterpriseLibrary.Security.Cryptography.dll Microsoft.Practices.EnterpriseLibrary.Security.dll Microsoft.Practices.EnterpriseLibrary.Validation.dll Microsoft.Practices.EnterpriseLibrary.Validation.Integration.AspNet.dll Microsoft.Practices.EnterpriseLibrary.Validation.Integration.WCF.dll Microsoft.Practices.EnterpriseLibrary.Validation.Integration.WinForms.dll Microsoft.Practices.ServiceLocation.dll Microsoft.Practices.Unity.Configuration.dll Microsoft.Practices.Unity.dll Microsoft.Practices.Unity.Interception.dll Enterprise Library Configuration Tool In addition to these assemblies you would get configuration tool “EntLibConfig-32.exe”. If you are targeting your application to .NET 4.0 framework then you would need to use “EntLibConfig.NET4.exe”. Optionally you can install Visual Studio 2008 and Visual Studio 2010 add-ins whilst installing of Enterprise Library. So that you can invoke the enterprise Library configuration from Visual Studio by right clicking on “app.config” or “web.config” file as shown below. I would suggest you to download the documentation from Codeplex which was released on May 2010. It consists 3MB of information. you can also find issue tracker to know various issues/bugs currently people talking about enterprise library. There is also discussion link takes you to community site where you can post your questions. In my next blog post, I would cover more on each block. span.fullpost {display:none;}

    Read the article

  • Grid Infrastructure 11.2 sur OEL 5.2 avec VMWare

    - by alain.duron(at)oracle.com
    En préparation, un sujet sur l'installation et la configuration de Grid Infrastructure 11.2 sur Oracle Enterprise Linux 5 (OEL 5.2 32bits). Plusieurs sites relatent ce type de config test, mais aucun ne semble décrire les problèmes pouvant survenir à l'installation, les résolutions possibles et les pièges à éviter, notamment sur la configuration d'ASMlib ou lors de la configuration du cluster par root.sh. La doc semble manquer cruellement dès qu'on rencontre un problème de configuration de Grid Infra sur VMWare, je vais tacher d'y remédier...A suivre :)

    Read the article

  • "apt-get -f install" fails with "/usr/bin/dpkg returned an error code (1)"

    - by parsley72
    I started out trying to install CVS: $ sudo apt-get install cvs Reading package lists... Done Building dependency tree Reading state information... Done You might want to run 'apt-get -f install' to correct these: The following packages have unmet dependencies: libcups2 : Breaks: libcups2:i386 (!= 1.5.3-0ubuntu3) but 1.5.3-0ubuntu4 is to be installed libcups2:i386 : Breaks: libcups2 (!= 1.5.3-0ubuntu4) but 1.5.3-0ubuntu3 is to be installed E: Unmet dependencies. Try 'apt-get -f install' with no packages (or specify a solution). But when I try this I get: $ sudo apt-get -f install Reading package lists... Done Building dependency tree Reading state information... Done Correcting dependencies... Done The following package was automatically installed and is no longer required: tzdata-java Use 'apt-get autoremove' to remove them. The following extra packages will be installed: libcups2 The following packages will be upgraded: libcups2 1 upgraded, 0 newly installed, 0 to remove and 0 not upgraded. 14 not fully installed or removed. Need to get 0 B/172 kB of archives. After this operation, 0 B of additional disk space will be used. Do you want to continue [Y/n]? y dpkg: error processing libcups2 (--configure): libcups2:amd64 1.5.3-0ubuntu3 cannot be configured because libcups2:i386 is in a different version (1.5.3-0ubuntu4) dpkg: error processing libcups2:i386 (--configure): libcups2:i386 1.5.3-0ubuntu4 cannot be configured because libcups2:amd64 is in a different version (1.5.3-0ubuntu3) dpkg: dependency problems prevent configuration of libcupsmime1: libcupsmime1 depends on libcups2 (>= 1.5~); however: Package libcups2 is not configured yet. dpkg: error processing libcupsmime1 (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of libcupscgi1: libcupscgi1 depends on libcups2 (>= 1.4.0); however: Package libcups2 is not configured yet. dpkg: error processing libcupscgi1 (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of libcupsppdc1: libcupsppdc1 depends on libcups2 (>= 1.4.0); however: Package libcups2 is not configured yet. dpkg: error processing libcupsppdc1 (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of cups-client: cups-client depends on libcups2 (>= 1.5.0); however: Package libcups2 is not configured yet. dpkg: error processing cups-client (--configure): dependency problems - leaviNo apport report written because the error message indicates its a followup error from a previous failure. No apport report written because the error message indicates its a followup error from a previous failure. No apport report written because MaxReports is reached already No apport report written because MaxReports is reached already No apport report written because MaxReports is reached already No apport report written because MaxReports is reached already No apport report written because MaxReports is reached already No apport report written because MaxReports is reached already No apport report written because MaxReports is reached already No apport report written because MaxReports is reached already No apport report written because MaxReports is reached already No apport report written because MaxReports is reached already ng unconfigured dpkg: dependency problems prevent configuration of cups-ppdc: cups-ppdc depends on libcups2 (>= 1.4.0); however: Package libcups2 is not configured yet. cups-ppdc depends on libcupsppdc1 (>= 1.4.0); however: Package libcupsppdc1 is not configured yet. dpkg: error processing cups-ppdc (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of cups: cups depends on libcups2 (>= 1.5.0); however: Package libcups2 is not configured yet. cups depends on libcupscgi1 (>= 1.4.2); however: Package libcupscgi1 is not configured yet. cups depends on libcupsmime1 (>= 1.5.0); however: Package libcupsmime1 is not configured yet. cups depends on libcupsppdc1 (>= 1.4.0); however: Package libcupsppdc1 is not configured yet. cups depends on cups-client (>= 1.5.3-0ubuntu4); however: Package cups-client is not configured yet. cups depends on cups-ppdc; however: Package cups-ppdc is not configured yet. dpkg: error processing cups (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of libcupsdriver1: libcupsdriver1 depends on libcups2 (>= 1.4.0); however: Package libcups2 is not configured yet. dpkg: error processing libcupsdriver1 (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of openjdk-7-jre-headless: openjdk-7-jre-headless depends on libcups2 (>= 1.4.0); however: Package libcups2 is not configured yet. dpkg: error processing openjdk-7-jre-headless (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of openjdk-7-jre: openjdk-7-jre depends on openjdk-7-jre-headless (= 7u7-2.3.2-1ubuntu0.12.04.1); however: Package openjdk-7-jre-headless is not configured yet. openjdk-7-jre depends on libcups2 (>= 1.4.0); however: Package libcups2 is not configured yet. dpkg: error processing openjdk-7-jre (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of cups-bsd: cups-bsd depends on libcups2 (>= 1.4.0); however: Package libcups2 is not configured yet. cups-bsd depends on cups-client (= 1.5.3-0ubuntu4); however: Package cups-client is not configured yet. dpkg: error processing cups-bsd (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of icedtea-7-jre-jamvm: icedtea-7-jre-jamvm depends on openjdk-7-jre-headless (= 7u7-2.3.2-1ubuntu0.12.04.1); however: Package openjdk-7-jre-headless is not configured yet. dpkg: error processing icedtea-7-jre-jamvm (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of openjdk-7-jre-lib: openjdk-7-jre-lib depends on openjdk-7-jre-headless (>= 7~b130~pre0); however: Package openjdk-7-jre-headless is not configured yet. dpkg: error processing openjdk-7-jre-lib (--configure): dependency problems - leaving unconfigured Errors were encountered while processing: libcups2 libcups2:i386 libcupsmime1 libcupscgi1 libcupsppdc1 cups-client cups-ppdc cups libcupsdriver1 openjdk-7-jre-headless openjdk-7-jre cups-bsd icedtea-7-jre-jamvm openjdk-7-jre-lib E: Sub-process /usr/bin/dpkg returned an error code (1) I've done "apt-get update" and "apt-get upgrade" and this hasn't fixed the problem: $ sudo apt-get upgrade Reading package lists... Done Building dependency tree Reading state information... Done You might want to run 'apt-get -f install' to correct these. The following packages have unmet dependencies: libcups2 : Breaks: libcups2:i386 (!= 1.5.3-0ubuntu3) but 1.5.3-0ubuntu4 is installed libcups2:i386 : Breaks: libcups2 (!= 1.5.3-0ubuntu4) but 1.5.3-0ubuntu3 is installed E: Unmet dependencies. Try using -f.

    Read the article

  • IIS7 FTP Setup - An error occured during the authentication process. 530 End Login failed

    - by robmzd
    I'm having a problem very similar to IIS 7.5 FTP IIS Manager Users Login Fail (530) on Windows Server 2008 R2 Standard. I have created an FTP site and IIS Manager user but am having trouble logging in. I could really do with getting this working with the IIS Manager user rather than by creating a new system user since I'm fairly restricted with those accounts. Here is the output when connecting locally through command prompt: C:\Windows\system32>ftp localhost Connected to MYSERVER. 220 Microsoft FTP Service User (MYSERVER:(none)): MyFtpLogin 331 Password required for MyFtpLogin. Password: *** 530-User cannot log in. Win32 error: Logon failure: unknown user name or bad password. Error details: An error occured during the authentication process. 530 End Login failed. I have followed the guide to configure ftp with iis manager authentication in iis 7 and Adding FTP Publishing to a Web Site in IIS 7 Things I have done and checked: The FTP Service is installed (along with FTP Extensibility). Local Service and Network Service have been given access to the site folder Permission has been given to the config files Granted read/write permissions to the FTP Root folder The Management Service is installed and running Enable remote connections is ticked with 'Windows credentials or IIS manager credentials' selected The IIS Manager User has been added to the server (root connection in the IIS connections branch) The new FTP site has been added IIS Manager Authentication has been added to the FTP authentication providers The IIS Manager user has been added to the IIS Manager Permissions list for the site Added Read/Write permissions for the user in the FTP Authorization Rules Here's a section of the applicationHost config file associated with the FTP site <site name="MySite" id="8"> <application path="/" applicationPool="MyAppPool"> <virtualDirectory path="/" physicalPath="D:\Websites\MySite" /> </application> <bindings> <binding protocol="http" bindingInformation="*:80:www.mydomain.co.uk" /> <binding protocol="ftp" bindingInformation="*:21:www.mydomain.co.uk" /> </bindings> <ftpServer> <security> <ssl controlChannelPolicy="SslAllow" dataChannelPolicy="SslAllow" /> <authentication> <basicAuthentication enabled="true" /> <customAuthentication> <providers> <add name="IisManagerAuth" enabled="true" /> </providers> </customAuthentication> </authentication> </security> </ftpServer> </site> ... <location path="MySite"> <system.ftpServer> <security> <authorization> <add accessType="Allow" users="MyFtpLogin" permissions="Read, Write" /> </authorization> </security> </system.ftpServer> </location> If I connect to the Site (not FTP) from my local IIS Manager using the same IIS Manager account details then it connects fine, I can browse files and change settings as I would locally (though I don't seem to have an option to upload files). Trying to connect via FTP though either through the browser or FileZilla etc... gives me: Status: Resolving address of www.mydomain.co.uk Status: Connecting to 123.456.12.123:21... Status: Connection established, waiting for welcome message... Response: 220 Microsoft FTP Service Command: USER MyFtpLogin Response: 331 Password required for MyFtpLogin. Command: PASS ********* Response: 530 User cannot log in. Error: Critical error Error: Could not connect to server I have tried collecting etw traces for ftp sessions, in the logs I get a FailBasicLogon followed by a FailCustomLogon, but no other info: FailBasicLogon SessionId={cad26a97-225d-45ba-ab1f-f6acd9046e55} | ErrorCode=0x8007052E StartCustomLogon SessionId={cad26a97-225d-45ba-ab1f-f6acd9046e55} | LogonProvider=IisManagerAuth StartCallProvider SessionId={cad26a97-225d-45ba-ab1f-f6acd9046e55} | provider=IisManagerAuth EndCallProvider SessionId={cad26a97-225d-45ba-ab1f-f6acd9046e55} EndCustomLogon SessionId={cad26a97-225d-45ba-ab1f-f6acd9046e55} FailCustomLogon SessionId={cad26a97-225d-45ba-ab1f-f6acd9046e55} | ErrorCode=0x8007052E FailFtpCommand SessionId={cad26a97-225d-45ba-ab1f-f6acd9046e55} | ReturnValue=0x8007052E | SubStatus=ERROR_DURING_AUTHENTICATION In the normal FTP logs I just get: 2012-10-23 16:13:11 123.456.12.123 - 123.456.12.123 21 ControlChannelOpened - - 0 0 e2d4e935-fb31-4f2c-af79-78d75d47c18e - 2012-10-23 16:13:11 123.456.12.123 - 123.456.12.123 21 USER MyFtpLogin 331 0 0 e2d4e935-fb31-4f2c-af79-78d75d47c18e - 2012-10-23 16:13:11 123.456.12.123 - 123.456.12.123 21 PASS *** 530 1326 41 e2d4e935-fb31-4f2c-af79-78d75d47c18e - 2012-10-23 16:13:11 123.456.12.123 - 123.456.12.123 21 ControlChannelClosed - - 0 0 e2d4e935-fb31-4f2c-af79-78d75d47c18e - If anyone has any ideas than I would be very grateful to hear them. Many thanks.

    Read the article

  • Setting up a VPN connection to Amazon VPC - routing

    - by Keeno
    I am having some real issues setting up a VPN between out office and AWS VPC. The "tunnels" appear to be up, however I don't know if they are configured correctly. The device I am using is a Netgear VPN Firewall - FVS336GV2 If you see in the attached config downloaded from VPC (#3 Tunnel Interface Configuration), it gives me some "inside" addresses for the tunnel. When setting up the IPsec tunnels do I use the inside tunnel IP's (e.g. 169.254.254.2/30) or do I use my internal network subnet (10.1.1.0/24) I have tried both, when I tried the local network (10.1.1.x) the tracert stops at the router. When I tried with the "inside" ips, the tracert to the amazon VPC (10.0.0.x) goes out over the internet. this all leads me to the next question, for this router, how do I set up stage #4, the static next hop? What are these seemingly random "inside" addresses and where did amazon generate them from? 169.254.254.x seems odd? With a device like this, is the VPN behind the firewall? I have tweaked any IP addresses below so that they are not "real". I am fully aware, this is probably badly worded. Please if there is any further info/screenshots that will help, let me know. Amazon Web Services Virtual Private Cloud IPSec Tunnel #1 ================================================================================ #1: Internet Key Exchange Configuration Configure the IKE SA as follows - Authentication Method : Pre-Shared Key - Pre-Shared Key : --- - Authentication Algorithm : sha1 - Encryption Algorithm : aes-128-cbc - Lifetime : 28800 seconds - Phase 1 Negotiation Mode : main - Perfect Forward Secrecy : Diffie-Hellman Group 2 #2: IPSec Configuration Configure the IPSec SA as follows: - Protocol : esp - Authentication Algorithm : hmac-sha1-96 - Encryption Algorithm : aes-128-cbc - Lifetime : 3600 seconds - Mode : tunnel - Perfect Forward Secrecy : Diffie-Hellman Group 2 IPSec Dead Peer Detection (DPD) will be enabled on the AWS Endpoint. We recommend configuring DPD on your endpoint as follows: - DPD Interval : 10 - DPD Retries : 3 IPSec ESP (Encapsulating Security Payload) inserts additional headers to transmit packets. These headers require additional space, which reduces the amount of space available to transmit application data. To limit the impact of this behavior, we recommend the following configuration on your Customer Gateway: - TCP MSS Adjustment : 1387 bytes - Clear Don't Fragment Bit : enabled - Fragmentation : Before encryption #3: Tunnel Interface Configuration Your Customer Gateway must be configured with a tunnel interface that is associated with the IPSec tunnel. All traffic transmitted to the tunnel interface is encrypted and transmitted to the Virtual Private Gateway. The Customer Gateway and Virtual Private Gateway each have two addresses that relate to this IPSec tunnel. Each contains an outside address, upon which encrypted traffic is exchanged. Each also contain an inside address associated with the tunnel interface. The Customer Gateway outside IP address was provided when the Customer Gateway was created. Changing the IP address requires the creation of a new Customer Gateway. The Customer Gateway inside IP address should be configured on your tunnel interface. Outside IP Addresses: - Customer Gateway : 217.33.22.33 - Virtual Private Gateway : 87.222.33.42 Inside IP Addresses - Customer Gateway : 169.254.254.2/30 - Virtual Private Gateway : 169.254.254.1/30 Configure your tunnel to fragment at the optimal size: - Tunnel interface MTU : 1436 bytes #4: Static Routing Configuration: To route traffic between your internal network and your VPC, you will need a static route added to your router. Static Route Configuration Options: - Next hop : 169.254.254.1 You should add static routes towards your internal network on the VGW. The VGW will then send traffic towards your internal network over the tunnels. IPSec Tunnel #2 ================================================================================ #1: Internet Key Exchange Configuration Configure the IKE SA as follows - Authentication Method : Pre-Shared Key - Pre-Shared Key : --- - Authentication Algorithm : sha1 - Encryption Algorithm : aes-128-cbc - Lifetime : 28800 seconds - Phase 1 Negotiation Mode : main - Perfect Forward Secrecy : Diffie-Hellman Group 2 #2: IPSec Configuration Configure the IPSec SA as follows: - Protocol : esp - Authentication Algorithm : hmac-sha1-96 - Encryption Algorithm : aes-128-cbc - Lifetime : 3600 seconds - Mode : tunnel - Perfect Forward Secrecy : Diffie-Hellman Group 2 IPSec Dead Peer Detection (DPD) will be enabled on the AWS Endpoint. We recommend configuring DPD on your endpoint as follows: - DPD Interval : 10 - DPD Retries : 3 IPSec ESP (Encapsulating Security Payload) inserts additional headers to transmit packets. These headers require additional space, which reduces the amount of space available to transmit application data. To limit the impact of this behavior, we recommend the following configuration on your Customer Gateway: - TCP MSS Adjustment : 1387 bytes - Clear Don't Fragment Bit : enabled - Fragmentation : Before encryption #3: Tunnel Interface Configuration Outside IP Addresses: - Customer Gateway : 217.33.22.33 - Virtual Private Gateway : 87.222.33.46 Inside IP Addresses - Customer Gateway : 169.254.254.6/30 - Virtual Private Gateway : 169.254.254.5/30 Configure your tunnel to fragment at the optimal size: - Tunnel interface MTU : 1436 bytes #4: Static Routing Configuration: Static Route Configuration Options: - Next hop : 169.254.254.5 You should add static routes towards your internal network on the VGW. The VGW will then send traffic towards your internal network over the tunnels. EDIT #1 After writing this post, I continued to fiddle and something started to work, just not very reliably. The local IPs to use when setting up the tunnels where indeed my network subnets. Which further confuses me over what these "inside" IP addresses are for. The problem is, results are not consistent what so ever. I can "sometimes" ping, I can "sometimes" RDP using the VPN. Sometimes, Tunnel 1 or Tunnel 2 can be up or down. When I came back into work today, Tunnel 1 was down, so I deleted it and re-created it from scratch. Now I cant ping anything, but Amazon AND the router are telling me tunnel 1/2 are fine. I guess the router/vpn hardware I have just isnt up to the job..... EDIT #2 Now Tunnel 1 is up, Tunnel 2 is down (I didn't change any settings) and I can ping/rdp again. EDIT #3 Screenshot of route table that the router has built up. Current state (tunnel 1 still up and going string, 2 is still down and wont re-connect)

    Read the article

  • EM12c Release 4: New Compliance features including DB STIG Standard

    - by DaveWolf
    Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 Enterprise Manager’s compliance framework is a powerful and robust feature that provides users the ability to continuously validate their target configurations against a specified standard. Enterprise Manager’s compliance library is filled with a wide variety of standards based on Oracle’s recommendations, best practices and security guidelines. These standards can be easily associated to a target to generate a report showing its degree of conformance to that standard. ( To get an overview of  Database compliance management in Enterprise Manager see this screenwatch. ) Starting with release 12.1.0.4 of Enterprise Manager the compliance library will contain a new standard based on the US Defense Information Systems Agency (DISA) Security Technical Implementation Guide (STIG) for Oracle Database 11g. According to the DISA website, “The STIGs contain technical guidance to ‘lock down’ information systems/software that might otherwise be vulnerable to a malicious computer attack.” In essence, a STIG is a technical checklist an administrator can follow to secure a system or software. Many US government entities are required to follow these standards however many non-US government entities and commercial companies base their standards directly or partially on these STIGs. You can find more information about the Oracle Database and other STIGs on the DISA website. The Oracle Database 11g STIG consists of two categories of checks, installation and instance. Installation checks focus primarily on the security of the Oracle Home while the instance checks focus on the configuration of the running database instance itself. If you view the STIG compliance standard in Enterprise Manager, you will see the rules organized into folders corresponding to these categories. Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 -"/ /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} The rule names contain a rule ID ( DG0020 for example ) which directly map to the check name in the STIG checklist along with a helpful brief description. The actual description field contains the text from the STIG documentation to aid in understanding the purpose of the check. All of the rules have also been documented in the Oracle Database Compliance Standards reference documentation. In order to use this standard both the OMS and agent must be at version 12.1.0.4 as it takes advantage of several features new in this release including: Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Agent-Side Compliance Rules Manual Compliance Rules Violation Suppression Additional BI Publisher Compliance Reports /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Agent-Side Compliance Rules Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Agent-side compliance rules are essentially the result of a tighter integration between Configuration Extensions and Compliance Rules. If you ever created customer compliance content in past versions of Enterprise Manager, you likely used Configuration Extensions to collect additional information into the EM repository so it could be used in a Repository compliance rule. This process although powerful, could be confusing to correctly model the SQL in the rule creation wizard. With agent-side rules, the user only needs to choose the Configuration Extension/Alias combination and that’s it. Enterprise Manager will do the rest for you. This tighter integration also means their lifecycle is managed together. When you associate an agent-side compliance standard to a target, the required Configuration Extensions will be deployed automatically for you. The opposite is also true, when you unassociated the compliance standard, the Configuration Extensions will also be undeployed. The Oracle Database STIG compliance standard is implemented as an agent-side standard which is why you simply need to associate the standard to your database targets without previously deploying the associated Configuration Extensions. You can learn more about using Agent-Side compliance rules in the screenwatch Using Agent-Side Compliance Rules on Enterprise Manager's Lifecycle Management page on OTN. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Manual Compliance Rules Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} There are many checks in the Oracle Database STIG as well as other common standards which simply cannot be automated. This could be something as simple as “Ensure the datacenter entrance is secured.” or complex as Oracle Database STIG Rule DG0186 – “The database should not be directly accessible from public or unauthorized networks”. These checks require a human to perform and attest to its successful completion. Enterprise Manager now supports these types of checks in Manual rules. When first associated to a target, each manual rule will generate a single violation. These violations must be manually cleared by a user who is in essence attesting to its successful completion. The user is able to permanently clear the violation or give a future date on which the violation will be regenerated. Setting a future date is useful when policy dictates a periodic re-validation of conformance wherein the user will have to reperform the check. The optional reason field gives the user an opportunity to provide details of the check results. Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Violation Suppression There are situations that require the need to permanently or temporarily suppress a legitimate violation or finding. These include approved exceptions and grace periods. Enterprise Manager now supports the ability to temporarily or permanently suppress a violation. Unlike when you clear a manual rule violation, suppression simply removes the violation from the compliance results UI and in turn its negative impact on the score. The violation still remains in the EM repository and can be accounted for in compliance reports. Temporarily suppressing a violation can give users a grace period in which to address an issue. If the issue is not addressed within the specified period, the violation will reappear in the results automatically. Again the user may enter a reason for the suppression which will be permanently saved with the event along with the suppressing user ID. Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Additional BI Publisher compliance reports As I am sure you have learned by now, BI Publisher now ships and is integrated with Enterprise Manager 12.1.0.4. This means users can take full advantage of the powerful reporting engine by using the Oracle provided reports or building their own. There are many new compliance related reports available in 12.1.0.4 covering all aspects including the association status, library as well as summary and detailed results reports.  10 New Compliance Reports Compliance Summary Report Example showing STIG results Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Conclusion Together with the Oracle Database 11g STIG compliance standard these features provide a complete solution for easily auditing and reporting the security posture of your Oracle Databases against this well known benchmark. You can view an overview presentation and demo in the screenwatch Using the STIG Compliance Standard on Enterprise Manager's Lifecycle Management page on OTN. Additional EM12c Compliance Management Information Compliance Management - Overview ( Presentation ) Compliance Management - Custom Compliance on Default Data (How To) Compliance Management - Custom Compliance using SQL Configuration Extension (How To) Compliance Management - Customer Compliance using Command Configuration Extension (How To)

    Read the article

  • Adding and accessing custom sections in your C# App.config

    - by deadlydog
    So I recently thought I’d try using the app.config file to specify some data for my application (such as URLs) rather than hard-coding it into my app, which would require a recompile and redeploy of my app if one of our URLs changed.  By using the app.config it allows a user to just open up the .config file that sits beside their .exe file and edit the URLs right there and then re-run the app; no recompiling, no redeployment necessary. I spent a good few hours fighting with the app.config and looking at examples on Google before I was able to get things to work properly.  Most of the examples I found showed you how to pull a value from the app.config if you knew the specific key of the element you wanted to retrieve, but it took me a while to find a way to simply loop through all elements in a section, so I thought I would share my solutions here.   Simple and Easy The easiest way to use the app.config is to use the built-in types, such as NameValueSectionHandler.  For example, if we just wanted to add a list of database server urls to use in my app, we could do this in the app.config file like so: 1: <?xml version="1.0" encoding="utf-8" ?> 2: <configuration> 3: <configSections> 4: <section name="ConnectionManagerDatabaseServers" type="System.Configuration.NameValueSectionHandler" /> 5: </configSections> 6: <startup> 7: <supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.5" /> 8: </startup> 9: <ConnectionManagerDatabaseServers> 10: <add key="localhost" value="localhost" /> 11: <add key="Dev" value="Dev.MyDomain.local" /> 12: <add key="Test" value="Test.MyDomain.local" /> 13: <add key="Live" value="Prod.MyDomain.com" /> 14: </ConnectionManagerDatabaseServers> 15: </configuration>   And then you can access these values in code like so: 1: string devUrl = string.Empty; 2: var connectionManagerDatabaseServers = ConfigurationManager.GetSection("ConnectionManagerDatabaseServers") as NameValueCollection; 3: if (connectionManagerDatabaseServers != null) 4: { 5: devUrl = connectionManagerDatabaseServers["Dev"].ToString(); 6: }   Sometimes though you don’t know what the keys are going to be and you just want to grab all of the values in that ConnectionManagerDatabaseServers section.  In that case you can get them all like this: 1: // Grab the Environments listed in the App.config and add them to our list. 2: var connectionManagerDatabaseServers = ConfigurationManager.GetSection("ConnectionManagerDatabaseServers") as NameValueCollection; 3: if (connectionManagerDatabaseServers != null) 4: { 5: foreach (var serverKey in connectionManagerDatabaseServers.AllKeys) 6: { 7: string serverValue = connectionManagerDatabaseServers.GetValues(serverKey).FirstOrDefault(); 8: AddDatabaseServer(serverValue); 9: } 10: }   And here we just assume that the AddDatabaseServer() function adds the given string to some list of strings.  So this works great, but what about when we want to bring in more values than just a single string (or technically you could use this to bring in 2 strings, where the “key” could be the other string you want to store; for example, we could have stored the value of the Key as the user-friendly name of the url).   More Advanced (and more complicated) So if you want to bring in more information than a string or two per object in the section, then you can no longer simply use the built-in System.Configuration.NameValueSectionHandler type provided for us.  Instead you have to build your own types.  Here let’s assume that we again want to configure a set of addresses (i.e. urls), but we want to specify some extra info with them, such as the user-friendly name, if they require SSL or not, and a list of security groups that are allowed to save changes made to these endpoints. So let’s start by looking at the app.config: 1: <?xml version="1.0" encoding="utf-8" ?> 2: <configuration> 3: <configSections> 4: <section name="ConnectionManagerDataSection" type="ConnectionManagerUpdater.Data.Configuration.ConnectionManagerDataSection, ConnectionManagerUpdater" /> 5: </configSections> 6: <startup> 7: <supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.5" /> 8: </startup> 9: <ConnectionManagerDataSection> 10: <ConnectionManagerEndpoints> 11: <add name="Development" address="Dev.MyDomain.local" useSSL="false" /> 12: <add name="Test" address="Test.MyDomain.local" useSSL="true" /> 13: <add name="Live" address="Prod.MyDomain.com" useSSL="true" securityGroupsAllowedToSaveChanges="ConnectionManagerUsers" /> 14: </ConnectionManagerEndpoints> 15: </ConnectionManagerDataSection> 16: </configuration>   The first thing to notice here is that my section is now using the type “ConnectionManagerUpdater.Data.Configuration.ConnectionManagerDataSection” (the fully qualified path to my new class I created) “, ConnectionManagerUpdater” (the name of the assembly my new class is in).  Next, you will also notice an extra layer down in the <ConnectionManagerDataSection> which is the <ConnectionManagerEndpoints> element.  This is a new collection class that I created to hold each of the Endpoint entries that are defined.  Let’s look at that code now: 1: using System; 2: using System.Collections.Generic; 3: using System.Configuration; 4: using System.Linq; 5: using System.Text; 6: using System.Threading.Tasks; 7:  8: namespace ConnectionManagerUpdater.Data.Configuration 9: { 10: public class ConnectionManagerDataSection : ConfigurationSection 11: { 12: /// <summary> 13: /// The name of this section in the app.config. 14: /// </summary> 15: public const string SectionName = "ConnectionManagerDataSection"; 16: 17: private const string EndpointCollectionName = "ConnectionManagerEndpoints"; 18:  19: [ConfigurationProperty(EndpointCollectionName)] 20: [ConfigurationCollection(typeof(ConnectionManagerEndpointsCollection), AddItemName = "add")] 21: public ConnectionManagerEndpointsCollection ConnectionManagerEndpoints { get { return (ConnectionManagerEndpointsCollection)base[EndpointCollectionName]; } } 22: } 23:  24: public class ConnectionManagerEndpointsCollection : ConfigurationElementCollection 25: { 26: protected override ConfigurationElement CreateNewElement() 27: { 28: return new ConnectionManagerEndpointElement(); 29: } 30: 31: protected override object GetElementKey(ConfigurationElement element) 32: { 33: return ((ConnectionManagerEndpointElement)element).Name; 34: } 35: } 36: 37: public class ConnectionManagerEndpointElement : ConfigurationElement 38: { 39: [ConfigurationProperty("name", IsRequired = true)] 40: public string Name 41: { 42: get { return (string)this["name"]; } 43: set { this["name"] = value; } 44: } 45: 46: [ConfigurationProperty("address", IsRequired = true)] 47: public string Address 48: { 49: get { return (string)this["address"]; } 50: set { this["address"] = value; } 51: } 52: 53: [ConfigurationProperty("useSSL", IsRequired = false, DefaultValue = false)] 54: public bool UseSSL 55: { 56: get { return (bool)this["useSSL"]; } 57: set { this["useSSL"] = value; } 58: } 59: 60: [ConfigurationProperty("securityGroupsAllowedToSaveChanges", IsRequired = false)] 61: public string SecurityGroupsAllowedToSaveChanges 62: { 63: get { return (string)this["securityGroupsAllowedToSaveChanges"]; } 64: set { this["securityGroupsAllowedToSaveChanges"] = value; } 65: } 66: } 67: }   So here the first class we declare is the one that appears in the <configSections> element of the app.config.  It is ConnectionManagerDataSection and it inherits from the necessary System.Configuration.ConfigurationSection class.  This class just has one property (other than the expected section name), that basically just says I have a Collection property, which is actually a ConnectionManagerEndpointsCollection, which is the next class defined.  The ConnectionManagerEndpointsCollection class inherits from ConfigurationElementCollection and overrides the requied fields.  The first tells it what type of Element to create when adding a new one (in our case a ConnectionManagerEndpointElement), and a function specifying what property on our ConnectionManagerEndpointElement class is the unique key, which I’ve specified to be the Name field. The last class defined is the actual meat of our elements.  It inherits from ConfigurationElement and specifies the properties of the element (which can then be set in the xml of the App.config).  The “ConfigurationProperty” attribute on each of the properties tells what we expect the name of the property to correspond to in each element in the app.config, as well as some additional information such as if that property is required and what it’s default value should be. Finally, the code to actually access these values would look like this: 1: // Grab the Environments listed in the App.config and add them to our list. 2: var connectionManagerDataSection = ConfigurationManager.GetSection(ConnectionManagerDataSection.SectionName) as ConnectionManagerDataSection; 3: if (connectionManagerDataSection != null) 4: { 5: foreach (ConnectionManagerEndpointElement endpointElement in connectionManagerDataSection.ConnectionManagerEndpoints) 6: { 7: var endpoint = new ConnectionManagerEndpoint() { Name = endpointElement.Name, ServerInfo = new ConnectionManagerServerInfo() { Address = endpointElement.Address, UseSSL = endpointElement.UseSSL, SecurityGroupsAllowedToSaveChanges = endpointElement.SecurityGroupsAllowedToSaveChanges.Split(',').Where(e => !string.IsNullOrWhiteSpace(e)).ToList() } }; 8: AddEndpoint(endpoint); 9: } 10: } This looks very similar to what we had before in the “simple” example.  The main points of interest are that we cast the section as ConnectionManagerDataSection (which is the class we defined for our section) and then iterate over the endpoints collection using the ConnectionManagerEndpoints property we created in the ConnectionManagerDataSection class.   Also, some other helpful resources around using app.config that I found (and for parts that I didn’t really explain in this article) are: How do you use sections in C# 4.0 app.config? (Stack Overflow) <== Shows how to use Section Groups as well, which is something that I did not cover here, but might be of interest to you. How to: Create Custom Configuration Sections Using Configuration Section (MSDN) ConfigurationSection Class (MSDN) ConfigurationCollectionAttribute Class (MSDN) ConfigurationElementCollection Class (MSDN)   I hope you find this helpful.  Feel free to leave a comment.  Happy Coding!

    Read the article

  • Unable to set password in IIS 8 for Domain User as ApplicationPool Identity

    - by Niels R.
    I'm trying to set a Domain User account as ApplicationPool Identity in IIS 8 (Windows 2012). When trying this using the IIS Management Console I always get an error: Value does not fall within the expected range. When trying to set the identity using appcmd.exe it fails on both the command setting the username and password or the command only setting the password. Setting the username is no problem. Trying to set both the username and password [FAIL]: >appcmd set config /section:applicationPools /[name='AppPoolName'].processModel.identityType:SpecificUser /[name='AppPoolName'].processModel.userName:DOMAIN\Username /[name='AppPoolName'].processModel.password:P4ssW0rd Applied configuration changes to section "system.applicationHost/applicationPools" for "MACHINE/WEBROOT/APPHOST" at configuration commit path "MACHINE/WEBROOT/APPHOST" ERROR ( hresult:80070057, message:Failed to commit configuration changes. The parameter is incorrect. ) Trying to set only the username [SUCCESS]: >appcmd set config /section:applicationPools /[name='AppPoolName'].processModel.identityType:SpecificUser /[name='AppPoolName'].processModel.userName:DOMAIN\Username Applied configuration changes to section "system.applicationHost/applicationPools" for "MACHINE/WEBROOT/APPHOST" at configuration commit path "MACHINE/WEBROOT/APPHOST" Trying to set the password after successfully setting the username [FAIL]: >appcmd set config /section:applicationPools /[name='AppPoolName'].processModel.identityType:SpecificUser /[name='AppPoolName'].processModel.password:P4ssW0rd Applied configuration changes to section "system.applicationHost/applicationPools" for "MACHINE/WEBROOT/APPHOST" at configuration commit path "MACHINE/WEBROOT/APPHOST" ERROR ( hresult:80070057, message:Failed to commit configuration changes. The parameter is incorrect. ) I added the Domain User to the IIS_IUSRS group and allowed it to "Log on as a service". Any suggestions what I might be doing wrong?

    Read the article

< Previous Page | 157 158 159 160 161 162 163 164 165 166 167 168  | Next Page >