Search Results

Search found 6108 results on 245 pages for 'entry'.

Page 162/245 | < Previous Page | 158 159 160 161 162 163 164 165 166 167 168 169  | Next Page >

  • Where can I find a compact programming keyboard with logical key placement?

    - by Lefler
    I recently, at the order of my chiropractor, bought a laptop stand to elevate my screen. A result of this is that I need a standalone keyboard. Normal keyboards have numeric keypads on the right side, which moves my mouse further to the right... not an optimal position chiropractically speaking. I don't use the numeric keypad, but all the compact keyboards I can find use some random placement algorithm on the arrow, page up/down, and most importantly -- the insert,delete,home and end keys. Those misplaced keys are crippling my code entry. Does anyone know of a keyboard that is minus the keypad, but places those VERY IMPORTANT keys in a more standard position?

    Read the article

  • How often does memcache on Google AppEngine lose data?

    - by Freed
    Memcache in general and on AppEngine in specific is unreliable in the sense that my data may be deleted from the cache for whatever reason at any point in time. However, in some cases there might be cases where a small risk may be worth the added performance using memcache could give, such as updating some data in memcache that gets saved periodically to some other, more reliable storage. Are there any numbers from Google that could give me an indication of the actual probability that a memcache entry would be lost from the cache before its expiration time, given that I keep within my quotas? Are there any reasons other than hardware failure and administrative operations such as machines at the data centers being upgraded/moved/replaced that would cause entries to be removed from memcache prematurely?

    Read the article

  • Use sudo su - <username> to access the <username's> account but sudo su - shouldn't be possible with a sudo user

    - by Winnie
    There is a requirement I got. My sudo users (for which their entry in sudoers file) should be able to access other user's account say Oracle using following command: sudo su - Oracle The above should work with giving current users password. But if the same user is firing the following command, sudo su - it shouldn't work and thus root access shouldnt be given to current user. I am not using su because because i dont want current user to know the credentials of other user(root,Oracle etc.). Can anyone please help me . Its urgent...

    Read the article

  • display data from tables that contain a null value

    - by user2631662
    I need the code below to say - if myReader reads a null entry a new method is called. At the moment it will not display data from tables that contain a null value conDataBase.Open(); myReader = cmdDataBase.ExecuteReader(); while (myReader.Read()) { if (myReader["Code_CodeID"] != DBNull.Value) { string sFirst = myReader["First"].ToString(); string sLast = myReader["Last"].ToString(); string sAdd1 = myReader["Address1"].ToString(); string sCode = myReader["Code"].ToString(); txtFirst.Text = sFirst; txtSecond.Text = sLast; txtadd1.Text = sAdd1; txtDeviceIMEI.Text = sCode; } } } else { //go to a new method } }

    Read the article

  • Insert a row and avoiding race condition (PHP/MySQL)

    - by justkevin
    I'm working on a multiplayer game which has a lobby-like area where players select "sectors" to enter. The lobby gateway is powered by PHP, while actual gameplay is handled by one or more Java servers. The datastore is MySQL. The happy path: A player chooses a sector and tells the lobby he'd like to enter. The lobby checks whether this is okay, including checking whether there are too many players in the sector (compares the entry count in sector assignments for that sector against the sector's max_players value). The player is added to the sector_assignments table pairing him with the sector. The player client receives a passkey that will let him connect to the appropriate game server. The race condition: If two players request access to the same sector at close to same time, I can envision a case where they are both added because there was one space free when their check was started and max players gets exceeded. Is the best solution LOCK TABLE on sector_assignments? Is there another option?

    Read the article

  • How can I use Javascript to access sub-elements?

    - by Steve
    I am dynamically creating forms dynamically according to a users actions. It is an entry-box and a two "buttons" for each instance. Each instance will be wrapped in a unique div tag. What I tried to do without success is when I dynamically create the "button" I attach a function with the input variable containing the div of its instance. This a brief excerpt: var newDivClass = document.getElementById("instance"+1); button1.innerHTML = "<a href=\"#\" onclick=\"buttons("+newDivClass+");\" id=\"button1\"> Button1 </a>"; function buttons(selected) { //I want this to select the first instance //of button1 found within div newDivClass selected.getElementById("button1"); //I also tried //this.getElementById("button1"); //selected.getChildren[0]; } The problem appears to be in passing newDivClass to the the actual function.

    Read the article

  • Sort Array in PHP

    - by DonCroce
    I have a script which gets some values from a DB. The structure of the vars is as the following: $dump["likes"] = 1234; $likes["data"][$i]["name"] = "ABCDEFG"; for($i=0;$i<=$max;$i++){ $data[$i]["likes"] = $dump["likes"]; $data[$i]["name"] = $likes["data"][$i]["name"]; } //Print Here Sorted array (highest value in "like" first) I just need a way to find out in which entry the biggest "likes" are :) So far i have tried array_multisort, but it showed me "inconsistent size" or some error... Thanks for all your help!

    Read the article

  • Problem getting textfield.text from other view controller

    - by wesleydyson
    Hey guys, I'm trying to add a textfield.text entry to an array. I want to pull the textfield.text from a text field in another view. Here's my code. - (void)addBookmark{ MultiViewViewController *mainView = [[MultiViewViewController alloc] init]; if (mainView.addressTextField.text.length>1) { NSString *addedString = [[NSString alloc] initWithFormat:@"%@", mainView.addressTextField.text]; [bookmarksArray addObject:addedString]; NSLog(@"addBookmark being called %@", mainView.addressTextField.text); } [bmTableView reloadData]; } The NSLog says the mainView.addressTextField.text is (NULL). What am I doing wrong?

    Read the article

  • Why does using set -e cause my script to fail when called in crontab

    - by SDGuero
    I have a bash script that performs several file operations. When any user runs this script, it executes successfully and outputs a few lines of text but when I try to cron it there are problems. It seems to run (I see an entry in cron log showing it was kicked off) but nothing happens, it doesn't output anything and doesn't do any of its file operations. It also doesn't appear in the running processes anywhere so it appears to be exiting out immediately. After some troubleshooting I found that removing "set -e" resolved the issue, it now runs from the system cron without a problem. So it works, but I'd rather have set -e enabled so the script exits if there is an error. Does anyone know why "set -e" is causing my script to exit? Thanks for the help, Ryan

    Read the article

  • Rails 3 does not render HTML as markup

    - by suebphatt
    Hello, Stackoverflow. I submitted a form, to create single row in SQL database table, as a blog entry: <p>This is a paragraph.</p> And the result, when I query it out for display, via Rails's ActiveRecord, it rendered like this, : <p>This is a paragraph.</p> and here's the code, when I view source in browser: &lt;p&gt;This is a paragraph.&lt;/p&gt; How do I solve this? Or I just have to convert the < and > by Javascript? Thank you :)

    Read the article

  • Grabbing the right record in a drop down from mysql

    - by 86Stang
    I'm using a form where the user can edit an entry. Everything is populating and all is well with the exception that I can't get the drop down to show the project that they've already assigned the image to. $project_qry = "SELECT * from projects ORDER BY title ASC"; $project_res = mysql_query($project_qry); $project_drop = "<select name=\"project_id\">\n"; while ($row = mysql_fetch_array($project_res)) { if ($project_id == $row[title]) { $project_drop .= "<option value=\"$row[id]\" selected>$row[title]</option>\n"; } else { $project_drop .= "<option value=\"$row[id]\">$row[title]</option>\n"; } } $project_drop .= "</select>\n"; I'm sure it's something devilishly simple but I'm stumped.

    Read the article

  • What if (stage) init(); means in actionscript ?

    - by asksuperuser
    I'm creating my first as3 with flashdevelop I don't understand what the instructions mean: package { import flash.display.Sprite; import flash.events.Event; public class Main extends Sprite { public function Main():void { if (stage) init(); else addEventListener(Event.ADDED_TO_STAGE, init); } private function init(e:Event = null):void { removeEventListener(Event.ADDED_TO_STAGE, init); // entry point } } } What if (stage) init(); means ? What is Event.ADDED_TO_STAGE ? Why remove listener in init ?

    Read the article

  • What is the answer to this homework about maps and collections? [closed]

    - by Bishan
    Maps collection is referred to an dictionary because of the way it works. Each entry into a maps collection involves a pair of objects. In a maps collection, an object associates the key which determines where the object is stored in the map. The key object in the maps collection can be duplicated. A stack which has Last In First Out storage mechanism can be considered as a maps collection. I think #1,#2,#3 and #5 are Correct in above, but I have doubt with #5. Am I correct?

    Read the article

  • SQL query for selecting most recent entries

    - by Mr_Skid_Marks
    A table in my database has a column, DATE_ADDED (stored in seconds). I want to extract all rows with the most recent date (aka largest value for DATE_ADDED). The only solution I have come up with is to SELECT all the rows in ASC (ascending) order, grab the last entry from the table, check the date on this, and perform another SELECT on the table but this time only for the discovered DATE_ADDED. Is it possibly to simplify this series of queries into a single one? My thought is I should be able to do a SELECT on all of the largest values in the table, but I am struggling to come up with a proper query.

    Read the article

  • External USB attached drive works in Windows XP but not in Windows 7. How to fix?

    - by irrational John
    Earlier this week I purchased this "N52300 EZQuest Pro" external hard drive enclosure from here. I can connect the enclosure using USB 2.0 and access the files in both NTFS partitions on the MBR partitioned drive when I use either Windows XP (SP3) or Mac OS X 10.6. So it works as expected in XP & Snow Leopard. However, the enclosure does not work in Windows 7 (Home Premium) either 64-bit or 32-bit or in Ubuntu 10.04 (kernel 2.6.32-23-generic). I'm thinking this must be a Windows 7 driver problem because the enclosure works in XP & Snow Leopard. I do know that no special drivers are required to use this enclosure. It is supported using the USB mass storage drivers included with XP and OS X. It should also work fine using the mass storage support in Windows 7, no? FWIW, I have also tried using 32-bit Windows 7 on both my desktop, a Gigabyte GA-965P-DS3 with a Pentium Dual-Core E6500 @ 2.93GHz, and on my early 2008 MacBook. I see the same failure in both cases that I see with 64-bit Windows 7. So it doesn't appear to be specific to one hardware platform. I'm hoping someone out there can help me either get the enclosure to work in Windows 7 or convince me that the enclosure hardware is bad and should be RMAed. At the moment though an RMA seems pointless since this appears to be a (Windows 7) device driver problem. I have tried to track down any updates to the mass storage drivers included with Windows 7 but have so far come up empty. Heck, I can't even figure out how to place a bug report with Microsoft since apparently the grace period for Windows 7 email support is only a few months. I came across a link to some USB troubleshooting steps in another question. I haven't had a chance to look over the suggestions on that site or try them yet. Maybe tomorrow if I have time ... ;-) I'll finish up with some more details about the problem. When I connect the enclosure using USB to Windows 7 at first it appears everything worked. Windows detects the drive and installs a driver for it. Looking in Device Manager there is an entry under the Hard Drives section with the title, Hitachi HDT721010SLA360 USB Device. When you open Windows Disk Management the first time after the enclosure has been attached the drive appears as "Not initialize" and I'm prompted to initialize it. This is bogus. After all, the drive worked fine in XP so I know it has already been initialized, partitioned, and formatted. So of course I never try to initialize it "again". (It's a 1 GB drive and I don't want to lose the data on it). Except for this first time, the drive never shows up in Disk Management again unless I uninstall the Hitachi HDT721010SLA360 USB Device entry under Hard Drives, unplug, and then replug the enclosure. If I do that then the process in the previous paragraph repeats. In Ubuntu the enclosure never shows up at all at the file system level. Below are an excerpt from kern.log and an excerpt from the result of lsusb -v after attaching the enclosure. It appears that Ubuntu at first recongnizes the enclosure and is attempting to attach it, but encounters errors which prevent it from doing so. Unfortunately, I don't know whether any of this info is useful or not. excerpt from kern.log [ 2684.240015] usb 1-2: new high speed USB device using ehci_hcd and address 22 [ 2684.393618] usb 1-2: configuration #1 chosen from 1 choice [ 2684.395399] scsi17 : SCSI emulation for USB Mass Storage devices [ 2684.395570] usb-storage: device found at 22 [ 2684.395572] usb-storage: waiting for device to settle before scanning [ 2689.390412] usb-storage: device scan complete [ 2689.390894] scsi 17:0:0:0: Direct-Access Hitachi HDT721010SLA360 ST6O PQ: 0 ANSI: 4 [ 2689.392237] sd 17:0:0:0: Attached scsi generic sg7 type 0 [ 2689.395269] sd 17:0:0:0: [sde] 1953525168 512-byte logical blocks: (1.00 TB/931 GiB) [ 2689.395632] sd 17:0:0:0: [sde] Write Protect is off [ 2689.395636] sd 17:0:0:0: [sde] Mode Sense: 11 00 00 00 [ 2689.395639] sd 17:0:0:0: [sde] Assuming drive cache: write through [ 2689.412003] sd 17:0:0:0: [sde] Assuming drive cache: write through [ 2689.412009] sde: sde1 sde2 [ 2689.455759] sd 17:0:0:0: [sde] Assuming drive cache: write through [ 2689.455765] sd 17:0:0:0: [sde] Attached SCSI disk [ 2692.620017] usb 1-2: reset high speed USB device using ehci_hcd and address 22 [ 2707.740014] usb 1-2: device descriptor read/64, error -110 [ 2722.970103] usb 1-2: device descriptor read/64, error -110 [ 2723.200027] usb 1-2: reset high speed USB device using ehci_hcd and address 22 [ 2738.320019] usb 1-2: device descriptor read/64, error -110 [ 2753.550024] usb 1-2: device descriptor read/64, error -110 [ 2753.780020] usb 1-2: reset high speed USB device using ehci_hcd and address 22 [ 2758.810147] usb 1-2: device descriptor read/8, error -110 [ 2763.940142] usb 1-2: device descriptor read/8, error -110 [ 2764.170014] usb 1-2: reset high speed USB device using ehci_hcd and address 22 [ 2769.200141] usb 1-2: device descriptor read/8, error -110 [ 2774.330137] usb 1-2: device descriptor read/8, error -110 [ 2774.440069] usb 1-2: USB disconnect, address 22 [ 2774.440503] sd 17:0:0:0: Device offlined - not ready after error recovery [ 2774.590023] usb 1-2: new high speed USB device using ehci_hcd and address 23 [ 2789.710020] usb 1-2: device descriptor read/64, error -110 [ 2804.940020] usb 1-2: device descriptor read/64, error -110 [ 2805.170026] usb 1-2: new high speed USB device using ehci_hcd and address 24 [ 2820.290019] usb 1-2: device descriptor read/64, error -110 [ 2835.520027] usb 1-2: device descriptor read/64, error -110 [ 2835.750018] usb 1-2: new high speed USB device using ehci_hcd and address 25 [ 2840.780085] usb 1-2: device descriptor read/8, error -110 [ 2845.910079] usb 1-2: device descriptor read/8, error -110 [ 2846.140023] usb 1-2: new high speed USB device using ehci_hcd and address 26 [ 2851.170112] usb 1-2: device descriptor read/8, error -110 [ 2856.300077] usb 1-2: device descriptor read/8, error -110 [ 2856.410027] hub 1-0:1.0: unable to enumerate USB device on port 2 [ 2856.730033] usb 3-2: new full speed USB device using uhci_hcd and address 11 [ 2871.850017] usb 3-2: device descriptor read/64, error -110 [ 2887.080014] usb 3-2: device descriptor read/64, error -110 [ 2887.310011] usb 3-2: new full speed USB device using uhci_hcd and address 12 [ 2902.430021] usb 3-2: device descriptor read/64, error -110 [ 2917.660013] usb 3-2: device descriptor read/64, error -110 [ 2917.890016] usb 3-2: new full speed USB device using uhci_hcd and address 13 [ 2922.911623] usb 3-2: device descriptor read/8, error -110 [ 2928.051753] usb 3-2: device descriptor read/8, error -110 [ 2928.280013] usb 3-2: new full speed USB device using uhci_hcd and address 14 [ 2933.301876] usb 3-2: device descriptor read/8, error -110 [ 2938.431993] usb 3-2: device descriptor read/8, error -110 [ 2938.540073] hub 3-0:1.0: unable to enumerate USB device on port 2 excerpt from lsusb -v Bus 001 Device 017: ID 0dc4:0000 Macpower Peripherals, Ltd Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x0dc4 Macpower Peripherals, Ltd idProduct 0x0000 bcdDevice 0.01 iManufacturer 1 EZ QUEST iProduct 2 USB Mass Storage iSerial 3 220417 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 5 Config0 bmAttributes 0xc0 Self Powered MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk (Zip) iInterface 4 Interface0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x01 EP 1 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Update: Results using Firewire to connect. Today I recieved a 1394b 9 pin to 1394a 6 pin cable which allowed me to connect the "EZQuest Pro" via Firewire. Everything works. When I use Firewire I can connect whether I'm using Windows 7 or Ubuntu 10.04. I even tried booting my Gigabyte desktop as an OS X 10.6.3 Hackintosh and it worked there as well. (Though if I recall correctly, it also worked when using USB 2.0 and booting OS X on the desktop. Certainly it works with USB 2.0 and my MacBook.) I believe the firmware on the device is at the latest level available, v1.07. I base this on the excerpt below from the OS X System Profiler which shows Firmware Revision: 0x107. Bottom line: It's nice that the enclosure is actually usable when I connect with Firewire. But I am still searching for an answer as to why it does not work correctly when using USB 2.0 in Windows 7 (and Ubuntu ... but really Windows 7 is my biggest concern). OXFORD IDE Device 1: Manufacturer: EZ QUEST Model: 0x0 GUID: 0x1D202E0220417 Maximum Speed: Up to 800 Mb/sec Connection Speed: Up to 400 Mb/sec Sub-units: OXFORD IDE Device 1 Unit: Unit Software Version: 0x10483 Unit Spec ID: 0x609E Firmware Revision: 0x107 Product Revision Level: ST6O Sub-units: OXFORD IDE Device 1 SBP-LUN: Capacity: 1 TB (1,000,204,886,016 bytes) Removable Media: Yes BSD Name: disk3 Partition Map Type: MBR (Master Boot Record) S.M.A.R.T. status: Not Supported

    Read the article

  • Mandatory profile on Terminal server fails to load. Userenv.log debug

    - by Datapimp23
    Hi, We're having a lot of corrupted profiles lately on our profile share. At the moment I have no clue why, but I decided to switch to one mandatory profile since the users can all use the same and there is no need to have seperate profiles for each user. Here's what I did. I logged into the Terminal server with a new user and configured some stuff (imported certificates and a few files). Then I logged out. Later as admin I copied the profile to another server and renamed it to bsilo. I made sure the user hive settings were adjusted. Everyone had access to the hive. I shared the bsilo folder with full access for everyone. I set the NTFS permissions to read, read & execute, list folder contents for domain users. I also renamed NTUSER.DAT to NTUSER.MAN. Now I set a env variable %manprofile% on the Terminal server that points to \server\bsilo\ntuser.man I set the env var as terminal services profile path for a test user. When I log in I as the user get the following output The system cannot find the path specified. Can somebody point me in the right direction. Thanks USERENV(1774.d18) 15:52:39:724 InitializePolicyProcessing: Initialised Machine Mutex/Events USERENV(1774.d18) 15:52:39:724 InitializePolicyProcessing: Initialised User Mutex/Events USERENV(1774.d18) 15:52:39:724 LibMain: Process Name: \??\C:\WINDOWS\system32\winlogon.exe USERENV(1774.d18) 15:52:48:005 LoadUserProfile: Yes, we can impersonate the user. Running as self USERENV(1774.d18) 15:52:48:005 ========================================================= USERENV(1774.d18) 15:52:48:005 LoadUserProfile: Entering, hToken = <0x340, lpProfileInfo = 0x6e5d8 USERENV(1774.d18) 15:52:48:005 LoadUserProfile: lpProfileInfo-dwFlags = <0x0 USERENV(1774.d18) 15:52:48:005 LoadUserProfile: lpProfileInfo-lpUserName = USERENV(1774.d18) 15:52:48:005 LoadUserProfile: lpProfileInfo-lpProfilePath = <\server\bsilo\ntuser.man USERENV(1774.d18) 15:52:48:005 LoadUserProfile: lpProfileInfo-lpDefaultPath = <\BDPINF5\netlogon\Default User USERENV(1774.d18) 15:52:48:005 LoadUserProfile: NULL server name USERENV(1774.d18) 15:52:48:005 LoadUserProfile: no thread token found, impersonating self. USERENV(1774.d18) 15:52:48:005 GetInterface: Returning rpc binding handle USERENV(218.2f94) 15:52:48:005 IProfileSecurityCallBack: client authenticated. USERENV(218.2f94) 15:52:48:005 DropClientContext: Got client token 000009B4, sid = S-1-5-18 USERENV(218.2f94) 15:52:48:005 MIDL_user_allocate enter USERENV(218.2f94) 15:52:48:005 DropClientContext: load profile object successfully made USERENV(218.2f94) 15:52:48:005 DropClientContext: Returning 0 USERENV(1774.d18) 15:52:48:005 LoadUserProfile: Calling DropClientToken (as self) succeeded USERENV(1774.d18) 15:52:48:005 CProfileDialog::Initialize : Cookie generated USERENV(1774.d18) 15:52:48:005 CProfileDialog::Initialize : Endpoint generated USERENV(218.1f38) 15:52:48:005 IProfileSecurityCallBack: client authenticated. USERENV(218.1f38) 15:52:48:020 LoadUserProfileI: RPC end point IProfileDialog_9D36D6DD48F0578A2A41B23D7A982E63 USERENV(218.1f38) 15:52:48:020 In LoadUserProfileP USERENV(218.1f38) 15:52:48:020 LoadUserProfile: Running as client, sid = S-1-5-18 USERENV(218.1f38) 15:52:48:020 ========================================================= USERENV(218.1f38) 15:52:48:020 LoadUserProfile: Entering, hToken = <0x98c, lpProfileInfo = 0x9c940 USERENV(218.1f38) 15:52:48:020 LoadUserProfile: lpProfileInfo-dwFlags = <0x0 USERENV(218.1f38) 15:52:48:020 LoadUserProfile: lpProfileInfo-lpUserName = USERENV(218.1f38) 15:52:48:020 LoadUserProfile: lpProfileInfo-lpProfilePath = <\server\bsilo\ntuser.man USERENV(218.1f38) 15:52:48:020 LoadUserProfile: lpProfileInfo-lpDefaultPath = <\BDPINF5\netlogon\Default User USERENV(218.1f38) 15:52:48:020 LoadUserProfile: NULL server name USERENV(218.1f38) 15:52:48:020 LoadUserProfile: User sid: S-1-5-21-807756564-1922302612-1565739477-22627 USERENV(218.1f38) 15:52:48:020 CSyncManager::EnterLock USERENV(218.1f38) 15:52:48:020 CSyncManager::EnterLock: No existing entry found USERENV(218.1f38) 15:52:48:020 CSyncManager::EnterLock: New entry created USERENV(218.1f38) 15:52:48:020 CHashTable::HashAdd: S-1-5-21-807756564-1922302612-1565739477-22627 added in bucket 11 USERENV(218.1f38) 15:52:48:020 LoadUserProfile: Wait succeeded. In critical section. USERENV(218.1f38) 15:52:48:864 GetOldSidString: Failed to open profile profile guid key with error 2 USERENV(218.1f38) 15:52:48:864 GetProfileSid: No Guid - Sid Mapping available USERENV(218.1f38) 15:52:48:864 TestIfUserProfileLoaded: return with error 2. USERENV(218.1f38) 15:52:48:864 GetOldSidString: Failed to open profile profile guid key with error 2 USERENV(218.1f38) 15:52:48:864 GetProfileSid: No Guid - Sid Mapping available USERENV(218.1f38) 15:52:48:864 LoadUserProfile: Expanded profile path is \server\bsilo\ntuser.man USERENV(218.1f38) 15:52:48:880 ParseProfilePath: Entering, lpProfilePath = <\server\bsilo\ntuser.man USERENV(218.1f38) 15:52:48:880 CheckXForestLogon: checking x-forest logon, user handle = 2444 USERENV(218.1f38) 15:52:48:880 CheckXForestLogon: policy set to disable XForest check USERENV(218.1f38) 15:52:48:880 ParseProfilePath: Mandatory profile (.man extension) USERENV(218.1f38) 15:52:49:239 AbleToBypassCSC: Try to bypass CSC USERENV(218.1f38) 15:52:49:239 AbleToBypassCSC: tried NPAddConnection3ForCSCAgent. Error 2109 USERENV(218.1f38) 15:52:49:239 AbleToBypassCSC: Share \server\bsilo mapped to drive E. Returned Path E:\ntuser.man USERENV(218.1f38) 15:52:49:239 ParseProfilePath: CSC bypassed. Profile path E:\ntuser.man USERENV(218.1f38) 15:52:49:255 ParseProfilePath: Tick Count = 0 USERENV(218.1f38) 15:52:49:255 ParseProfilePath: GetFileAttributes found something with attributes <0x2022 USERENV(218.1f38) 15:52:49:255 ParseProfilePath: Found a file USERENV(218.1f38) 15:52:49:255 ReportError: Impersonating user. USERENV(218.1f38) 15:52:49:255 ReportError: Logging Error DETAIL - The system cannot find the path specified. USERENV(218.1f38) 15:52:49:255 GetInterface: Returning rpc binding handle USERENV(218.1f38) 15:52:49:255 ReportError: RPC End point IProfileDialog_9D36D6DD48F0578A2A41B23D7A982E63 USERENV(218.1f38) 15:52:49:255 ReportError: waiting on rpc async event USERENV(1774.2398) 15:52:49:255 ErrorDialogEx: Calling DialogBoxParam USERENV(1774.2398) 15:52:49:270 ErrorDlgProc:: DialogBoxParam USERENV(218.1f38) 15:52:52:177 RpcAsyncCompleteCall finished, status = 0 USERENV(218.1f38) 15:52:52:177 ReleaseInterface: Releasing rpc binding handle USERENV(218.1f38) 15:52:52:177 LoadUserProfile: ParseProfilePath returned FALSE USERENV(218.1f38) 15:52:52:177 CancelCSCBypassedConnection: Cancelling connection of E: USERENV(218.1f38) 15:52:52:177 CancelCSCBypassedConnection: Connection deleted. USERENV(218.1f38) 15:52:52:177 CSyncManager::LeaveLock USERENV(218.1f38) 15:52:52:192 CSyncManager::LeaveLock: Lock released USERENV(218.1f38) 15:52:52:192 CHashTable::HashDelete: S-1-5-21-807756564-1922302612-1565739477-22627 deleted USERENV(218.1f38) 15:52:52:192 CSyncManager::LeaveLock: Lock deleted USERENV(218.1f38) 15:52:52:192 LoadUserProfile: 003 About Reverted back to user <00000000 USERENV(218.1f38) 15:52:52:192 LoadUserProfile: Leaving with a value of 0. USERENV(218.1f38) 15:52:52:192 ========================================================= USERENV(218.1f38) 15:52:52:192 LoadUserProfileI: LoadUserProfileP failed with 3 USERENV(218.1f38) 15:52:52:192 LoadUserProfileI: returning 3 USERENV(1774.d18) 15:52:52:192 LoadUserProfile: Running as self USERENV(1774.d18) 15:52:52:192 LoadUserProfile: Calling LoadUserProfileI failed. err = 3 USERENV(218.200c) 15:52:52:192 IProfileSecurityCallBack: client authenticated. USERENV(218.200c) 15:52:52:192 ReleaseClientContext: Releasing context USERENV(218.200c) 15:52:52:192 ReleaseClientContext_s: Releasing context USERENV(218.200c) 15:52:52:192 MIDL_user_free enter USERENV(1774.d18) 15:52:52:192 ReleaseInterface: Releasing rpc binding handle USERENV(1774.d18) 15:52:52:192 LoadUserProfile: Returning FALSE. Error = 3

    Read the article

  • Using PHP OCI8 with 32-bit PHP on Windows 64-bit

    - by christopher.jones
    The world migration from 32-bit to 64-bit operating systems is gaining pace. However I've seen a couple of customers having difficulty with the PHP OCI8 extension and Oracle DB on Windows 64-bit platforms. The errors vary depending how PHP is run. They may appear in the Apache or PHP log: Unable to load dynamic library 'C:\Program Files (x86)\PHP\ext\php_oci8_11g.dll' - %1 is not a valid Win32 application. or Warning oci_connect(): OCIEnvNlsCreate() failed. There is something wrong with your system - please check that PATH includes the directory with Oracle Instant Client libraries Other than IIS permission issues a common cause seems to be trying to use PHP with libraries from an Oracle 64-bit database on the same machine. There is currently no 64-bit version of PHP on http://php.net/ so there is a library mismatch. A solution is to install Oracle Instant Client 32-bit and make sure that PHP uses these libraries, while not interferring with the 64-bit database on the same machine. Warning: The following hacky steps come untested from a Linux user: Unzip Oracle Instant Client 32-bit and move it to C:\WINDOWS\SYSWOW64\INSTANTCLIENT_11_2. You may need to do this in a console with elevated permissions. Edit your PATH environment variable and insert C:\WINDOWS\SYSTEM32\INSTANTCLIENT_11_2 in the directory list before the entry for the Oracle Home library. Windows makes it so all 32-bit applications that reference C:\WINDOWS\SYSTEM32 actually see the contents of the C:\WINDOWS\SYSWOW64 directory. Your 64-bit database won't find an Instant Client in the real, physical C:\WINDOWS\SYSTEM32 directory and will continue to use the database libraries. Some of our Windows team are concerned about this hack and prefer a more "correct" solution that (i) doesn't require changing the Windows system directory (ii) doesn't add to the "memory" burden about what was configured on the system (iii) works when there are multiple database versions installed. The solution is to write a script which will set the 64-bit (or 32-bit) Oracle libraries in the path as needed before invoking the relevant bit-ness application. This does have a weakness when the application is started as a service. As a footnote: If you don't have a local database and simply need to have 32-bit and 64-bit Instant Client accessible at the same time, try the "symbolic" link approach covered in the hack in this OTN forum thread. Reminder warning: This blog post came untested from a Linux user.

    Read the article

  • Metro: Declarative Data Binding

    - by Stephen.Walther
    The goal of this blog post is to describe how declarative data binding works in the WinJS library. In particular, you learn how to use both the data-win-bind and data-win-bindsource attributes. You also learn how to use calculated properties and converters to format the value of a property automatically when performing data binding. By taking advantage of WinJS data binding, you can use the Model-View-ViewModel (MVVM) pattern when building Metro style applications with JavaScript. By using the MVVM pattern, you can prevent your JavaScript code from spinning into chaos. The MVVM pattern provides you with a standard pattern for organizing your JavaScript code which results in a more maintainable application. Using Declarative Bindings You can use the data-win-bind attribute with any HTML element in a page. The data-win-bind attribute enables you to bind (associate) an attribute of an HTML element to the value of a property. Imagine, for example, that you want to create a product details page. You want to show a product object in a page. In that case, you can create the following HTML page to display the product details: <!DOCTYPE html> <html> <head> <meta charset="utf-8"> <title>Application1</title> <!-- WinJS references --> <link href="//Microsoft.WinJS.0.6/css/ui-dark.css" rel="stylesheet"> <script src="//Microsoft.WinJS.0.6/js/base.js"></script> <script src="//Microsoft.WinJS.0.6/js/ui.js"></script> <!-- Application1 references --> <link href="/css/default.css" rel="stylesheet"> <script src="/js/default.js"></script> </head> <body> <h1>Product Details</h1> <div class="field"> Product Name: <span data-win-bind="innerText:name"></span> </div> <div class="field"> Product Price: <span data-win-bind="innerText:price"></span> </div> <div class="field"> Product Picture: <br /> <img data-win-bind="src:photo;alt:name" /> </div> </body> </html> The HTML page above contains three data-win-bind attributes – one attribute for each product property displayed. You use the data-win-bind attribute to set properties of the HTML element associated with the data-win-attribute. The data-win-bind attribute takes a semicolon delimited list of element property names and data source property names: data-win-bind=”elementPropertyName:datasourcePropertyName; elementPropertyName:datasourcePropertyName;…” In the HTML page above, the first two data-win-bind attributes are used to set the values of the innerText property of the SPAN elements. The last data-win-bind attribute is used to set the values of the IMG element’s src and alt attributes. By the way, using data-win-bind attributes is perfectly valid HTML5. The HTML5 standard enables you to add custom attributes to an HTML document just as long as the custom attributes start with the prefix data-. So you can add custom attributes to an HTML5 document with names like data-stephen, data-funky, or data-rover-dog-is-hungry and your document will validate. The product object displayed in the page above with the data-win-bind attributes is created in the default.js file: (function () { "use strict"; var app = WinJS.Application; app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { var product = { name: "Tesla", price: 80000, photo: "/images/TeslaPhoto.png" }; WinJS.Binding.processAll(null, product); } }; app.start(); })(); In the code above, a product object is created with a name, price, and photo property. The WinJS.Binding.processAll() method is called to perform the actual binding (Don’t confuse WinJS.Binding.processAll() and WinJS.UI.processAll() – these are different methods). The first parameter passed to the processAll() method represents the root element for the binding. In other words, binding happens on this element and its child elements. If you provide the value null, then binding happens on the entire body of the document (document.body). The second parameter represents the data context. This is the object that has the properties which are displayed with the data-win-bind attributes. In the code above, the product object is passed as the data context parameter. Another word for data context is view model.  Creating Complex View Models In the previous section, we used the data-win-bind attribute to display the properties of a simple object: a single product. However, you can use binding with more complex view models including view models which represent multiple objects. For example, the view model in the following default.js file represents both a customer and a product object. Furthermore, the customer object has a nested address object: (function () { "use strict"; var app = WinJS.Application; app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { var viewModel = { customer: { firstName: "Fred", lastName: "Flintstone", address: { street: "1 Rocky Way", city: "Bedrock", country: "USA" } }, product: { name: "Bowling Ball", price: 34.55 } }; WinJS.Binding.processAll(null, viewModel); } }; app.start(); })(); The following page displays the customer (including the customer address) and the product. Notice that you can use dot notation to refer to child objects in a view model such as customer.address.street. <!DOCTYPE html> <html> <head> <meta charset="utf-8"> <title>Application1</title> <!-- WinJS references --> <link href="//Microsoft.WinJS.0.6/css/ui-dark.css" rel="stylesheet"> <script src="//Microsoft.WinJS.0.6/js/base.js"></script> <script src="//Microsoft.WinJS.0.6/js/ui.js"></script> <!-- Application1 references --> <link href="/css/default.css" rel="stylesheet"> <script src="/js/default.js"></script> </head> <body> <h1>Customer Details</h1> <div class="field"> First Name: <span data-win-bind="innerText:customer.firstName"></span> </div> <div class="field"> Last Name: <span data-win-bind="innerText:customer.lastName"></span> </div> <div class="field"> Address: <address> <span data-win-bind="innerText:customer.address.street"></span> <br /> <span data-win-bind="innerText:customer.address.city"></span> <br /> <span data-win-bind="innerText:customer.address.country"></span> </address> </div> <h1>Product</h1> <div class="field"> Name: <span data-win-bind="innerText:product.name"></span> </div> <div class="field"> Price: <span data-win-bind="innerText:product.price"></span> </div> </body> </html> A view model can be as complicated as you need and you can bind the view model to a view (an HTML document) by using declarative bindings. Creating Calculated Properties You might want to modify a property before displaying the property. For example, you might want to format the product price property before displaying the property. You don’t want to display the raw product price “80000”. Instead, you want to display the formatted price “$80,000”. You also might need to combine multiple properties. For example, you might need to display the customer full name by combining the values of the customer first and last name properties. In these situations, it is tempting to call a function when performing binding. For example, you could create a function named fullName() which concatenates the customer first and last name. Unfortunately, the WinJS library does not support the following syntax: <span data-win-bind=”innerText:fullName()”></span> Instead, in these situations, you should create a new property in your view model that has a getter. For example, the customer object in the following default.js file includes a property named fullName which combines the values of the firstName and lastName properties: (function () { "use strict"; var app = WinJS.Application; app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { var customer = { firstName: "Fred", lastName: "Flintstone", get fullName() { return this.firstName + " " + this.lastName; } }; WinJS.Binding.processAll(null, customer); } }; app.start(); })(); The customer object has a firstName, lastName, and fullName property. Notice that the fullName property is defined with a getter function. When you read the fullName property, the values of the firstName and lastName properties are concatenated and returned. The following HTML page displays the fullName property in an H1 element. You can use the fullName property in a data-win-bind attribute in exactly the same way as any other property. <!DOCTYPE html> <html> <head> <meta charset="utf-8"> <title>Application1</title> <!-- WinJS references --> <link href="//Microsoft.WinJS.0.6/css/ui-dark.css" rel="stylesheet"> <script src="//Microsoft.WinJS.0.6/js/base.js"></script> <script src="//Microsoft.WinJS.0.6/js/ui.js"></script> <!-- Application1 references --> <link href="/css/default.css" rel="stylesheet"> <script src="/js/default.js"></script> </head> <body> <h1 data-win-bind="innerText:fullName"></h1> <div class="field"> First Name: <span data-win-bind="innerText:firstName"></span> </div> <div class="field"> Last Name: <span data-win-bind="innerText:lastName"></span> </div> </body> </html> Creating a Converter In the previous section, you learned how to format the value of a property by creating a property with a getter. This approach makes sense when the formatting logic is specific to a particular view model. If, on the other hand, you need to perform the same type of formatting for multiple view models then it makes more sense to create a converter function. A converter function is a function which you can apply whenever you are using the data-win-bind attribute. Imagine, for example, that you want to create a general function for displaying dates. You always want to display dates using a short format such as 12/25/1988. The following JavaScript file – named converters.js – contains a shortDate() converter: (function (WinJS) { var shortDate = WinJS.Binding.converter(function (date) { return date.getMonth() + 1 + "/" + date.getDate() + "/" + date.getFullYear(); }); // Export shortDate WinJS.Namespace.define("MyApp.Converters", { shortDate: shortDate }); })(WinJS); The file above uses the Module Pattern, a pattern which is used through the WinJS library. To learn more about the Module Pattern, see my blog entry on namespaces and modules: http://stephenwalther.com/blog/archive/2012/02/22/windows-web-applications-namespaces-and-modules.aspx The file contains the definition for a converter function named shortDate(). This function converts a JavaScript date object into a short date string such as 12/1/1988. The converter function is created with the help of the WinJS.Binding.converter() method. This method takes a normal function and converts it into a converter function. Finally, the shortDate() converter is added to the MyApp.Converters namespace. You can call the shortDate() function by calling MyApp.Converters.shortDate(). The default.js file contains the customer object that we want to bind. Notice that the customer object has a firstName, lastName, and birthday property. We will use our new shortDate() converter when displaying the customer birthday property: (function () { "use strict"; var app = WinJS.Application; app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { var customer = { firstName: "Fred", lastName: "Flintstone", birthday: new Date("12/1/1988") }; WinJS.Binding.processAll(null, customer); } }; app.start(); })(); We actually use our shortDate converter in the HTML document. The following HTML document displays all of the customer properties: <!DOCTYPE html> <html> <head> <meta charset="utf-8"> <title>Application1</title> <!-- WinJS references --> <link href="//Microsoft.WinJS.0.6/css/ui-dark.css" rel="stylesheet"> <script src="//Microsoft.WinJS.0.6/js/base.js"></script> <script src="//Microsoft.WinJS.0.6/js/ui.js"></script> <!-- Application1 references --> <link href="/css/default.css" rel="stylesheet"> <script src="/js/default.js"></script> <script type="text/javascript" src="js/converters.js"></script> </head> <body> <h1>Customer Details</h1> <div class="field"> First Name: <span data-win-bind="innerText:firstName"></span> </div> <div class="field"> Last Name: <span data-win-bind="innerText:lastName"></span> </div> <div class="field"> Birthday: <span data-win-bind="innerText:birthday MyApp.Converters.shortDate"></span> </div> </body> </html> Notice the data-win-bind attribute used to display the birthday property. It looks like this: <span data-win-bind="innerText:birthday MyApp.Converters.shortDate"></span> The shortDate converter is applied to the birthday property when the birthday property is bound to the SPAN element’s innerText property. Using data-win-bindsource Normally, you pass the view model (the data context) which you want to use with the data-win-bind attributes in a page by passing the view model to the WinJS.Binding.processAll() method like this: WinJS.Binding.processAll(null, viewModel); As an alternative, you can specify the view model declaratively in your markup by using the data-win-datasource attribute. For example, the following default.js script exposes a view model with the fully-qualified name of MyWinWebApp.viewModel: (function () { "use strict"; var app = WinJS.Application; app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { // Create view model var viewModel = { customer: { firstName: "Fred", lastName: "Flintstone" }, product: { name: "Bowling Ball", price: 12.99 } }; // Export view model to be seen by universe WinJS.Namespace.define("MyWinWebApp", { viewModel: viewModel }); // Process data-win-bind attributes WinJS.Binding.processAll(); } }; app.start(); })(); In the code above, a view model which represents a customer and a product is exposed as MyWinWebApp.viewModel. The following HTML page illustrates how you can use the data-win-bindsource attribute to bind to this view model: <!DOCTYPE html> <html> <head> <meta charset="utf-8"> <title>Application1</title> <!-- WinJS references --> <link href="//Microsoft.WinJS.0.6/css/ui-dark.css" rel="stylesheet"> <script src="//Microsoft.WinJS.0.6/js/base.js"></script> <script src="//Microsoft.WinJS.0.6/js/ui.js"></script> <!-- Application1 references --> <link href="/css/default.css" rel="stylesheet"> <script src="/js/default.js"></script> </head> <body> <h1>Customer Details</h1> <div data-win-bindsource="MyWinWebApp.viewModel.customer"> <div class="field"> First Name: <span data-win-bind="innerText:firstName"></span> </div> <div class="field"> Last Name: <span data-win-bind="innerText:lastName"></span> </div> </div> <h1>Product</h1> <div data-win-bindsource="MyWinWebApp.viewModel.product"> <div class="field"> Name: <span data-win-bind="innerText:name"></span> </div> <div class="field"> Price: <span data-win-bind="innerText:price"></span> </div> </div> </body> </html> The data-win-bindsource attribute is used twice in the page above: it is used with the DIV element which contains the customer details and it is used with the DIV element which contains the product details. If an element has a data-win-bindsource attribute then all of the child elements of that element are affected. The data-win-bind attributes of all of the child elements are bound to the data source represented by the data-win-bindsource attribute. Summary The focus of this blog entry was data binding using the WinJS library. You learned how to use the data-win-bind attribute to bind the properties of an HTML element to a view model. We also discussed several advanced features of data binding. We examined how to create calculated properties by including a property with a getter in your view model. We also discussed how you can create a converter function to format the value of a view model property when binding the property. Finally, you learned how to use the data-win-bindsource attribute to specify a view model declaratively.

    Read the article

  • SSIS - Access Denied with UNC paths - The file name is a device or contains invalid characters

    - by simonsabin
    I spent another day tearing my hair out yesterday trying to resolve an issue with SSIS packages runnning in SQLAgent (not got much left at the moment, maybe I should contact the SSIS team for a wig). My situation was that I am deploying packages to a development server, and to provide isolation I was running jobs with a proxy account that only had access to the development servers. Proxies are an awesome feature and mean that you should never have to "just run the job as sysadmin". The issue I was facing was that the job step was failing. The job step was a simple execution of the package.The following errors appeared in my log file. I always check the "Log step output in history" for a job step, this ensures you get all the output from the command that you run. I'll blog about this later. If looking at the output in sysdtslog90 then you will have an entry with datacode -1073573533 and error message File or directory "<filename>" represented by connection "<connection>" does not exist.  Not exactly helpful. If you get the output from the console then you will also get these errors. 0xC0202070 "The file name property is not valid. The file name is a device or contains invalid characters." 0xC001401E "specified in the connection was not valid." It appears this error is due to the use of a UNC path and the account runnnig the package not having access to all the folders in the path. Solution To solve this you need to ensure that the proxy account has access to ALL folders in the path you are accessing. To check this works, logon as the relevant proxy user, or run a command window as the specified user. Then try and do net use \\server\share and then do a dir for each folder in the path and check you have access. If these work and you still have the problem then you have some other problem, sorry. The following are posts on experts exchange that also discuss this,http://www.experts-exchange.com/Microsoft/Development/MS-SQL-Server/SSIS/Q_24056047.htmlhttp://www.experts-exchange.com/Microsoft/Development/MS-SQL-Server/SSIS/Q_23968903.html This blog had a post about it being a 64 bit issue. That definitely wasn't the issue for me as I was on a 32 bit server http://blogs.perkinsconsulting.com/post/64-bit-SQL-Server-2005-SSIS-and-UNC-paths-Part-2.aspx  

    Read the article

  • SQL Server Editions and Integration Services

    The SQL Server 2005 and SQL Server 2008 product family has quite a few editions now, so what does this mean for SQL Server Integration Services? Starting from the bottom we have the free edition known as Express, and the entry level Workgroup edition, as well as the new Web edition. None of these three include the full SSIS product, but they do all include the SQL Server Import and Export Wizard, with access to basic data sources but nothing more, so for simple loading and extraction of data this should suffice. You will not be able to build packages though, this is just a one shot deal aimed at using the wizard on an ad-hoc basis. To get the full power of Integration Services you need to start with Standard edition. This includes the BI Development Studio, for building your own packages, and fully functional IDE integrated into Visual Studio. (You get the full VS 2005/2008 IDE with the product). All core functions will be available but with a restricted set of transformations and tasks. The SQL Server 2005 Features Comparison or Features Supported by the Editions of SQL Server 2008 describes standard edition as having basic transforms, compared to Enterprise which includes the advanced transforms. I think basic is a little harsh considering the power you get with Standard, but the advanced covers the truly ground-breaking capabilities of data mining, text mining and cleansing or fuzzy transforms. The power of performing these operations within your ETL pipeline should not be underestimated, but not all processes will require these capabilities, so it seems like a reasonable delineation. Thankfully there are no feature limitations or artificial governors within Standard compared to Enterprise. The same control flow and data flow engines underpin both editions, with the same configuration and deployment options allowing you to work seamlessly between environments and editions if using the common components. In fact there are no govenors at all in SSIS, so whilst the SQL Database engine is limited to 4 CPUs in Standard edition, SSIS is only limited by the base operating system. The advanced transforms only available with Enterprise edition: Data Mining Training Destination Data Mining Query Component Fuzzy Grouping Fuzzy Lookup Term Extraction Term Lookup Dimension Processing Destination Partition Processing Destination The advanced tasks only available with Enterprise edition: Data Mining Query Task So in summary, if you want SQL Server Integration Services, you need SQL Server Standard edition, and for the more advanced tasks and transforms you need SQL Server Enterprise edition. To recap, the answer to the often asked question is no, SQL Server Integration Services is not available in SQL Server Express or Workgroup editions.

    Read the article

  • Example WLST Script to Obtain JDBC and JTA MBean Values

    - by Daniel Mortimer
    Introduction Following on from the blog entry "Get an Offline or Online WebLogic Domain Summary Using WLST!", I have had a request to create a smaller example which only collects a selection of JDBC (System Resource) and JTA configuration and runtime MBeans values. So, here it is. Download Sample Script You can grab the sample script by clicking here. Instructions to Run: 1. After download, extract the zip to the machine hosting the WebLogic environment. You should have three directories along with a readme.txt output Sample_Output scripts 2. In the scripts directory, find the start wrapper script startWLSTJDBCSummarizer.sh (Unix) or startWLSTJDBCSummarizer.cmd (MS Windows). Open the appropriate file in an editor and change the environment variable settings to suit your system. Example - startWLSTDomainSummarizer.cmd set WL_HOME=D:\product\FMW11g\wlserver_10.3 set DOMAIN_HOME=D:\product\FMW11g\user_projects\domains\MyDomain set WLST_OUTPUT_PATH=D:\WLSTDomainSummarizer\output\ set WLST_OUTPUT_FILE=WLST_JDBC_Summary_Via_MBeans.html call "%WL_HOME%\common\bin\wlst.cmd" WLS_JDBC_Summary_Online.py Note: The WLST_OUTPUT_PATH directory value must have a trailing slash. If there is no trailing slash, the script will error and not continue.  3. Run the shell / command line wrapper script. It should launch WLST and kick off "WLS_JDBC_Summary_Online.py". This will hit you with some prompts e.g. Is your domain Admin Server up and running and do you have the connection details? (Y /N ): Y Enter connection URL to Admin Server e.g t3://mymachine.acme.com:7001 : t3://localhost:7001 Enter weblogic username: weblogic Enter weblogic username password (function prompt 1): welcome1 (Note: the value typed in for password will not be echoed back to the console). 4. If the scripts run successfully, you should get a HTML summary in the specified output directory. See example screenshots below: Screenshot 1 - JDBC System Resource Tab Page  Screenshot 2 - JTA Tab Page 5. For the HTML to render correctly, ensure the .js and .css files provided (review the output directory created by the zip file extraction) are accessible. For example, to view the HTML locally (without using a web server), place the HTML output, jquery-ui.js, spry.js and wlstsummarizer.css in the same directory. Disclaimer This is a sample script. I have tested it against WebLogic Server 10.3.6 domains on MS Windows and Unix.  I cannot guarantee that the script will run error free or produce the expected output on your system. If you have any feedback add a comment to the blog. I will endeavour to fix any problems with my WLST code. Credits JQuery: http://jquery.com/ Spry (Adobe) : https://github.com/adobe/Spryhttp://www.red-team-design.com/cool-headings-with-pseudo-elements

    Read the article

  • Toorcon14

    - by danx
    Toorcon 2012 Information Security Conference San Diego, CA, http://www.toorcon.org/ Dan Anderson, October 2012 It's almost Halloween, and we all know what that means—yes, of course, it's time for another Toorcon Conference! Toorcon is an annual conference for people interested in computer security. This includes the whole range of hackers, computer hobbyists, professionals, security consultants, press, law enforcement, prosecutors, FBI, etc. We're at Toorcon 14—see earlier blogs for some of the previous Toorcon's I've attended (back to 2003). This year's "con" was held at the Westin on Broadway in downtown San Diego, California. The following are not necessarily my views—I'm just the messenger—although I could have misquoted or misparaphrased the speakers. Also, I only reviewed some of the talks, below, which I attended and interested me. MalAndroid—the Crux of Android Infections, Aditya K. Sood Programming Weird Machines with ELF Metadata, Rebecca "bx" Shapiro Privacy at the Handset: New FCC Rules?, Valkyrie Hacking Measured Boot and UEFI, Dan Griffin You Can't Buy Security: Building the Open Source InfoSec Program, Boris Sverdlik What Journalists Want: The Investigative Reporters' Perspective on Hacking, Dave Maas & Jason Leopold Accessibility and Security, Anna Shubina Stop Patching, for Stronger PCI Compliance, Adam Brand McAfee Secure & Trustmarks — a Hacker's Best Friend, Jay James & Shane MacDougall MalAndroid—the Crux of Android Infections Aditya K. Sood, IOActive, Michigan State PhD candidate Aditya talked about Android smartphone malware. There's a lot of old Android software out there—over 50% Gingerbread (2.3.x)—and most have unpatched vulnerabilities. Of 9 Android vulnerabilities, 8 have known exploits (such as the old Gingerbread Global Object Table exploit). Android protection includes sandboxing, security scanner, app permissions, and screened Android app market. The Android permission checker has fine-grain resource control, policy enforcement. Android static analysis also includes a static analysis app checker (bouncer), and a vulnerablity checker. What security problems does Android have? User-centric security, which depends on the user to grant permission and make smart decisions. But users don't care or think about malware (the're not aware, not paranoid). All they want is functionality, extensibility, mobility Android had no "proper" encryption before Android 3.0 No built-in protection against social engineering and web tricks Alternative Android app markets are unsafe. Simply visiting some markets can infect Android Aditya classified Android Malware types as: Type A—Apps. These interact with the Android app framework. For example, a fake Netflix app. Or Android Gold Dream (game), which uploads user files stealthy manner to a remote location. Type K—Kernel. Exploits underlying Linux libraries or kernel Type H—Hybrid. These use multiple layers (app framework, libraries, kernel). These are most commonly used by Android botnets, which are popular with Chinese botnet authors What are the threats from Android malware? These incude leak info (contacts), banking fraud, corporate network attacks, malware advertising, malware "Hackivism" (the promotion of social causes. For example, promiting specific leaders of the Tunisian or Iranian revolutions. Android malware is frequently "masquerated". That is, repackaged inside a legit app with malware. To avoid detection, the hidden malware is not unwrapped until runtime. The malware payload can be hidden in, for example, PNG files. Less common are Android bootkits—there's not many around. What they do is hijack the Android init framework—alteering system programs and daemons, then deletes itself. For example, the DKF Bootkit (China). Android App Problems: no code signing! all self-signed native code execution permission sandbox — all or none alternate market places no robust Android malware detection at network level delayed patch process Programming Weird Machines with ELF Metadata Rebecca "bx" Shapiro, Dartmouth College, NH https://github.com/bx/elf-bf-tools @bxsays on twitter Definitions. "ELF" is an executable file format used in linking and loading executables (on UNIX/Linux-class machines). "Weird machine" uses undocumented computation sources (I think of them as unintended virtual machines). Some examples of "weird machines" are those that: return to weird location, does SQL injection, corrupts the heap. Bx then talked about using ELF metadata as (an uintended) "weird machine". Some ELF background: A compiler takes source code and generates a ELF object file (hello.o). A static linker makes an ELF executable from the object file. A runtime linker and loader takes ELF executable and loads and relocates it in memory. The ELF file has symbols to relocate functions and variables. ELF has two relocation tables—one at link time and another one at loading time: .rela.dyn (link time) and .dynsym (dynamic table). GOT: Global Offset Table of addresses for dynamically-linked functions. PLT: Procedure Linkage Tables—works with GOT. The memory layout of a process (not the ELF file) is, in order: program (+ heap), dynamic libraries, libc, ld.so, stack (which includes the dynamic table loaded into memory) For ELF, the "weird machine" is found and exploited in the loader. ELF can be crafted for executing viruses, by tricking runtime into executing interpreted "code" in the ELF symbol table. One can inject parasitic "code" without modifying the actual ELF code portions. Think of the ELF symbol table as an "assembly language" interpreter. It has these elements: instructions: Add, move, jump if not 0 (jnz) Think of symbol table entries as "registers" symbol table value is "contents" immediate values are constants direct values are addresses (e.g., 0xdeadbeef) move instruction: is a relocation table entry add instruction: relocation table "addend" entry jnz instruction: takes multiple relocation table entries The ELF weird machine exploits the loader by relocating relocation table entries. The loader will go on forever until told to stop. It stores state on stack at "end" and uses IFUNC table entries (containing function pointer address). The ELF weird machine, called "Brainfu*k" (BF) has: 8 instructions: pointer inc, dec, inc indirect, dec indirect, jump forward, jump backward, print. Three registers - 3 registers Bx showed example BF source code that implemented a Turing machine printing "hello, world". More interesting was the next demo, where bx modified ping. Ping runs suid as root, but quickly drops privilege. BF modified the loader to disable the library function call dropping privilege, so it remained as root. Then BF modified the ping -t argument to execute the -t filename as root. It's best to show what this modified ping does with an example: $ whoami bx $ ping localhost -t backdoor.sh # executes backdoor $ whoami root $ The modified code increased from 285948 bytes to 290209 bytes. A BF tool compiles "executable" by modifying the symbol table in an existing ELF executable. The tool modifies .dynsym and .rela.dyn table, but not code or data. Privacy at the Handset: New FCC Rules? "Valkyrie" (Christie Dudley, Santa Clara Law JD candidate) Valkyrie talked about mobile handset privacy. Some background: Senator Franken (also a comedian) became alarmed about CarrierIQ, where the carriers track their customers. Franken asked the FCC to find out what obligations carriers think they have to protect privacy. The carriers' response was that they are doing just fine with self-regulation—no worries! Carriers need to collect data, such as missed calls, to maintain network quality. But carriers also sell data for marketing. Verizon sells customer data and enables this with a narrow privacy policy (only 1 month to opt out, with difficulties). The data sold is not individually identifiable and is aggregated. But Verizon recommends, as an aggregation workaround to "recollate" data to other databases to identify customers indirectly. The FCC has regulated telephone privacy since 1934 and mobile network privacy since 2007. Also, the carriers say mobile phone privacy is a FTC responsibility (not FCC). FTC is trying to improve mobile app privacy, but FTC has no authority over carrier / customer relationships. As a side note, Apple iPhones are unique as carriers have extra control over iPhones they don't have with other smartphones. As a result iPhones may be more regulated. Who are the consumer advocates? Everyone knows EFF, but EPIC (Electrnic Privacy Info Center), although more obsecure, is more relevant. What to do? Carriers must be accountable. Opt-in and opt-out at any time. Carriers need incentive to grant users control for those who want it, by holding them liable and responsible for breeches on their clock. Location information should be added current CPNI privacy protection, and require "Pen/trap" judicial order to obtain (and would still be a lower standard than 4th Amendment). Politics are on a pro-privacy swing now, with many senators and the Whitehouse. There will probably be new regulation soon, and enforcement will be a problem, but consumers will still have some benefit. Hacking Measured Boot and UEFI Dan Griffin, JWSecure, Inc., Seattle, @JWSdan Dan talked about hacking measured UEFI boot. First some terms: UEFI is a boot technology that is replacing BIOS (has whitelisting and blacklisting). UEFI protects devices against rootkits. TPM - hardware security device to store hashs and hardware-protected keys "secure boot" can control at firmware level what boot images can boot "measured boot" OS feature that tracks hashes (from BIOS, boot loader, krnel, early drivers). "remote attestation" allows remote validation and control based on policy on a remote attestation server. Microsoft pushing TPM (Windows 8 required), but Google is not. Intel TianoCore is the only open source for UEFI. Dan has Measured Boot Tool at http://mbt.codeplex.com/ with a demo where you can also view TPM data. TPM support already on enterprise-class machines. UEFI Weaknesses. UEFI toolkits are evolving rapidly, but UEFI has weaknesses: assume user is an ally trust TPM implicitly, and attached to computer hibernate file is unprotected (disk encryption protects against this) protection migrating from hardware to firmware delays in patching and whitelist updates will UEFI really be adopted by the mainstream (smartphone hardware support, bank support, apathetic consumer support) You Can't Buy Security: Building the Open Source InfoSec Program Boris Sverdlik, ISDPodcast.com co-host Boris talked about problems typical with current security audits. "IT Security" is an oxymoron—IT exists to enable buiness, uptime, utilization, reporting, but don't care about security—IT has conflict of interest. There's no Magic Bullet ("blinky box"), no one-size-fits-all solution (e.g., Intrusion Detection Systems (IDSs)). Regulations don't make you secure. The cloud is not secure (because of shared data and admin access). Defense and pen testing is not sexy. Auditors are not solution (security not a checklist)—what's needed is experience and adaptability—need soft skills. Step 1: First thing is to Google and learn the company end-to-end before you start. Get to know the management team (not IT team), meet as many people as you can. Don't use arbitrary values such as CISSP scores. Quantitive risk assessment is a myth (e.g. AV*EF-SLE). Learn different Business Units, legal/regulatory obligations, learn the business and where the money is made, verify company is protected from script kiddies (easy), learn sensitive information (IP, internal use only), and start with low-hanging fruit (customer service reps and social engineering). Step 2: Policies. Keep policies short and relevant. Generic SANS "security" boilerplate policies don't make sense and are not followed. Focus on acceptable use, data usage, communications, physical security. Step 3: Implementation: keep it simple stupid. Open source, although useful, is not free (implementation cost). Access controls with authentication & authorization for local and remote access. MS Windows has it, otherwise use OpenLDAP, OpenIAM, etc. Application security Everyone tries to reinvent the wheel—use existing static analysis tools. Review high-risk apps and major revisions. Don't run different risk level apps on same system. Assume host/client compromised and use app-level security control. Network security VLAN != segregated because there's too many workarounds. Use explicit firwall rules, active and passive network monitoring (snort is free), disallow end user access to production environment, have a proxy instead of direct Internet access. Also, SSL certificates are not good two-factor auth and SSL does not mean "safe." Operational Controls Have change, patch, asset, & vulnerability management (OSSI is free). For change management, always review code before pushing to production For logging, have centralized security logging for business-critical systems, separate security logging from administrative/IT logging, and lock down log (as it has everything). Monitor with OSSIM (open source). Use intrusion detection, but not just to fulfill a checkbox: build rules from a whitelist perspective (snort). OSSEC has 95% of what you need. Vulnerability management is a QA function when done right: OpenVas and Seccubus are free. Security awareness The reality is users will always click everything. Build real awareness, not compliance driven checkbox, and have it integrated into the culture. Pen test by crowd sourcing—test with logging COSSP http://www.cossp.org/ - Comprehensive Open Source Security Project What Journalists Want: The Investigative Reporters' Perspective on Hacking Dave Maas, San Diego CityBeat Jason Leopold, Truthout.org The difference between hackers and investigative journalists: For hackers, the motivation varies, but method is same, technological specialties. For investigative journalists, it's about one thing—The Story, and they need broad info-gathering skills. J-School in 60 Seconds: Generic formula: Person or issue of pubic interest, new info, or angle. Generic criteria: proximity, prominence, timeliness, human interest, oddity, or consequence. Media awareness of hackers and trends: journalists becoming extremely aware of hackers with congressional debates (privacy, data breaches), demand for data-mining Journalists, use of coding and web development for Journalists, and Journalists busted for hacking (Murdock). Info gathering by investigative journalists include Public records laws. Federal Freedom of Information Act (FOIA) is good, but slow. California Public Records Act is a lot stronger. FOIA takes forever because of foot-dragging—it helps to be specific. Often need to sue (especially FBI). CPRA is faster, and requests can be vague. Dumps and leaks (a la Wikileaks) Journalists want: leads, protecting ourselves, our sources, and adapting tools for news gathering (Google hacking). Anonomity is important to whistleblowers. They want no digital footprint left behind (e.g., email, web log). They don't trust encryption, want to feel safe and secure. Whistleblower laws are very weak—there's no upside for whistleblowers—they have to be very passionate to do it. Accessibility and Security or: How I Learned to Stop Worrying and Love the Halting Problem Anna Shubina, Dartmouth College Anna talked about how accessibility and security are related. Accessibility of digital content (not real world accessibility). mostly refers to blind users and screenreaders, for our purpose. Accessibility is about parsing documents, as are many security issues. "Rich" executable content causes accessibility to fail, and often causes security to fail. For example MS Word has executable format—it's not a document exchange format—more dangerous than PDF or HTML. Accessibility is often the first and maybe only sanity check with parsing. They have no choice because someone may want to read what you write. Google, for example, is very particular about web browser you use and are bad at supporting other browsers. Uses JavaScript instead of links, often requiring mouseover to display content. PDF is a security nightmare. Executible format, embedded flash, JavaScript, etc. 15 million lines of code. Google Chrome doesn't handle PDF correctly, causing several security bugs. PDF has an accessibility checker and PDF tagging, to help with accessibility. But no PDF checker checks for incorrect tags, untagged content, or validates lists or tables. None check executable content at all. The "Halting Problem" is: can one decide whether a program will ever stop? The answer, in general, is no (Rice's theorem). The same holds true for accessibility checkers. Language-theoretic Security says complicated data formats are hard to parse and cannot be solved due to the Halting Problem. W3C Web Accessibility Guidelines: "Perceivable, Operable, Understandable, Robust" Not much help though, except for "Robust", but here's some gems: * all information should be parsable (paraphrasing) * if not parsable, cannot be converted to alternate formats * maximize compatibility in new document formats Executible webpages are bad for security and accessibility. They say it's for a better web experience. But is it necessary to stuff web pages with JavaScript for a better experience? A good example is The Drudge Report—it has hand-written HTML with no JavaScript, yet drives a lot of web traffic due to good content. A bad example is Google News—hidden scrollbars, guessing user input. Solutions: Accessibility and security problems come from same source Expose "better user experience" myth Keep your corner of Internet parsable Remember "Halting Problem"—recognize false solutions (checking and verifying tools) Stop Patching, for Stronger PCI Compliance Adam Brand, protiviti @adamrbrand, http://www.picfun.com/ Adam talked about PCI compliance for retail sales. Take an example: for PCI compliance, 50% of Brian's time (a IT guy), 960 hours/year was spent patching POSs in 850 restaurants. Often applying some patches make no sense (like fixing a browser vulnerability on a server). "Scanner worship" is overuse of vulnerability scanners—it gives a warm and fuzzy and it's simple (red or green results—fix reds). Scanners give a false sense of security. In reality, breeches from missing patches are uncommon—more common problems are: default passwords, cleartext authentication, misconfiguration (firewall ports open). Patching Myths: Myth 1: install within 30 days of patch release (but PCI §6.1 allows a "risk-based approach" instead). Myth 2: vendor decides what's critical (also PCI §6.1). But §6.2 requires user ranking of vulnerabilities instead. Myth 3: scan and rescan until it passes. But PCI §11.2.1b says this applies only to high-risk vulnerabilities. Adam says good recommendations come from NIST 800-40. Instead use sane patching and focus on what's really important. From NIST 800-40: Proactive: Use a proactive vulnerability management process: use change control, configuration management, monitor file integrity. Monitor: start with NVD and other vulnerability alerts, not scanner results. Evaluate: public-facing system? workstation? internal server? (risk rank) Decide:on action and timeline Test: pre-test patches (stability, functionality, rollback) for change control Install: notify, change control, tickets McAfee Secure & Trustmarks — a Hacker's Best Friend Jay James, Shane MacDougall, Tactical Intelligence Inc., Canada "McAfee Secure Trustmark" is a website seal marketed by McAfee. A website gets this badge if they pass their remote scanning. The problem is a removal of trustmarks act as flags that you're vulnerable. Easy to view status change by viewing McAfee list on website or on Google. "Secure TrustGuard" is similar to McAfee. Jay and Shane wrote Perl scripts to gather sites from McAfee and search engines. If their certification image changes to a 1x1 pixel image, then they are longer certified. Their scripts take deltas of scans to see what changed daily. The bottom line is change in TrustGuard status is a flag for hackers to attack your site. Entire idea of seals is silly—you're raising a flag saying if you're vulnerable.

    Read the article

  • Evolution Of High Definition TV Viewing

    - by Gopinath
    The following guest post is written by Rob, who is also blogging on entertainment technology topics on iwantsky.com Gone are the days when you need to squint to be able to see the emotions on the faces of Humphrey Bogart and Ingrid Bergman as the lovers bid each other adieu in the classic film Casablanca. These days, watching an ordinary ant painstakingly carry a leaf in Animal Planet can be an exhilarating experience as you get to see not only the slightest movement but also the demarcation line between the insect’s head, thorax and abdomen. The crystal clear imagery was made possible by the sharp minds and the tinkering hands of the scientists that have designed the modern world’s HDTV. What is HDTV and what makes people so agog to have this new innovation in TV watching? HDTV stands for High Definition TV. Television viewing has indeed made a big leap. From the grainy black and whites, TV viewing had moved to colored TVs, progressed to SD TVs and now to HDTV. HDTV is the emerging trend in TV viewing as it delivers bigger and clearer pictures and better audio. Viewers can have a cinema-like TV viewing experience right in the comforts of their own home. With HDTV the viewer is allowed to have a better viewing range. With Standard (SD) TV, the viewer has to be at a distance that is from 3 to 6 times the size of the screen. HDTV allows the viewer to enjoy sharper and clearer images as it is possible to sit at a distance that is 1.5 or 3 times the size of the screen without noticing any image pixilation. Although HDTV appears to be a fairly new innovation, this system has actually existed in various forms years ago. Development of the HDTV was started in Europe as early as 1940s. However, the NTSC and the PAL/SECAM, the two analog TV standards became dominant and became popular worldwide. The analog TV was replaced by the digital TV platform in the 1990s. Even during the analog era, attempts have been made to develop HDTV. Japan has come out with MUSE system. However, due to channel bandwidth requirement concerns, the program was shelved. The entry of four organizations into the HDTV market spurred the development of a beneficial coalition. The AT&T, ATRC, MIT and Zenith HDTV combined forces. In 1993, a Grand Alliance was formed. This group is composed of researchers and HDTV manufacturers. A common standard for the broadcast system of HDTV was developed. In 1995, the system was tested and found successful. With the higher screen resolution of HDTV, viewing has never been more enjoyable. [Image courtesy: samsung] This article titled,Evolution Of High Definition TV Viewing, was originally published at Tech Dreams. Grab our rss feed or fan us on Facebook to get updates from us.

    Read the article

  • Windows Phone 7 Design using Expression Blend - Resources

    - by Nikita Polyakov
    I’ve been doing a series of talks across Florida regarding Windows Phone 7 Design using Microsoft Expression Blend 4. I discuss the WP7 phone and application experience; show how to use Expression Blend toolset to effectively design such apps. Next presentation is on 5/4/2010 at 6:30PM EST will be a webcast format over LiveMeeting at Ft. Lauderdale Online group. Registration and the LiveMeeting link are both here: http://www.fladotnet.com/Reg.aspx?EventID=459 [I will post a link if it’s recorded]   Here are the resources from my presentations: The Biggest source is the Windows Phone UI and Design Language video from MIX10 Windows Phone 7 Design Guide as it’s found on the WP7 Dev Home Page Study The Silverlight Mobile Tutorials on official Silverlight website I will be blogging a separate entry for a new demo app that will showcase the elements I presented. I suggest you actually watch all of the MIX videos about SL and Design as great primer to get you thinking the WP7 way.   A lot happening with WP7Dev and it’s just the beginning! So watch these Twitter accounts and blogs: @Ckindel - Charlie Kindel - WP7 Dev Head http://blogs.msdn.com/ckindel @WP7Dev - Official Dev Twitter @WP7 - Official WP7 Twitter Peter Torr - http://blogs.msdn.com/ptorr Mike Harsh - http://blogs.msdn.com/mharsh Shawn Oster - http://www.shawnoster.com   Other worthwhile mention my local friends speaking and blogging about Windows Phone 7: Bill Reiss is doing great presentations on Building games with XNA for Windows Phone 7. Be on the lookout for those around Florida. Bill is a Silverlight MVP and has a legacy of XNA and Silverlight games, see his site. Kevin Wolf aka ByteMaster he is a Device Application Developer MVP with tremendous experience building mobile applications. He has developed WinMo-GF a multi-platform gaming framework. Get these tools and get creating! You will need the following components installed in this order: Expression Blend 4 Beta Windows Phone Developer Tools Microsoft Expression Blend Add-in Preview for Windows Phone Microsoft Expression Blend SDK Preview for Windows Phone Want more training? Don’t forget that Channel 9 has complete walkthroughs of their WP7 Training Kit posted online. PS: To continue with all this design talk check out Microsoft .toolbox “Learn to create Silverlight applications using Expression Studio and to apply fundamental design principles.” A great website with a lot of design tutorials set up as a wonderful full course on design all for free, including a great forum community and neat little avatars you can build yourself.

    Read the article

  • AuthnRequest Settings in OIF / SP

    - by Damien Carru
    In this article, I will list the various OIF/SP settings that affect how an AuthnRequest message is created in OIF in a Federation SSO flow. The AuthnRequest message is used by an SP to start a Federation SSO operation and to indicate to the IdP how the operation should be executed: How the user should be challenged at the IdP Whether or not the user should be challenged at the IdP, even if a session already exists at the IdP for this user Which NameID format should be requested in the SAML Assertion Which binding (Artifact or HTTP-POST) should be requested from the IdP to send the Assertion Which profile should be used by OIF/SP to send the AuthnRequest message Enjoy the reading! Protocols The SAML 2.0, SAML 1.1 and OpenID 2.0 protocols define different message elements and rules that allow an administrator to influence the Federation SSO flows in different manners, when the SP triggers an SSO operation: SAML 2.0 allows extensive customization via the AuthnRequest message SAML 1.1 does not allow any customization, since the specifications do not define an authentication request message OpenID 2.0 allows for some customization, mainly via the OpenID 2.0 extensions such as PAPE or UI SAML 2.0 OIF/SP allows the customization of the SAML 2.0 AuthnRequest message for the following elements: ForceAuthn: Boolean indicating whether or not the IdP should force the user for re-authentication, even if the user has still a valid session By default set to false IsPassive Boolean indicating whether or not the IdP is allowed to interact with the user as part of the Federation SSO operation. If false, the Federation SSO operation might result in a failure with the NoPassive error code, because the IdP will not have been able to identify the user By default set to false RequestedAuthnContext Element indicating how the user should be challenged at the IdP If the SP requests a Federation Authentication Method unknown to the IdP or for which the IdP is not configured, then the Federation SSO flow will result in a failure with the NoAuthnContext error code By default missing NameIDPolicy Element indicating which NameID format the IdP should include in the SAML Assertion If the SP requests a NameID format unknown to the IdP or for which the IdP is not configured, then the Federation SSO flow will result in a failure with the InvalidNameIDPolicy error code If missing, the IdP will generally use the default NameID format configured for this SP partner at the IdP By default missing ProtocolBinding Element indicating which SAML binding should be used by the IdP to redirect the user to the SP with the SAML Assertion Set to Artifact or HTTP-POST By default set to HTTP-POST OIF/SP also allows the administrator to configure the server to: Set which binding should be used by OIF/SP to redirect the user to the IdP with the SAML 2.0 AuthnRequest message: Redirect or HTTP-POST By default set to Redirect Set which binding should be used by OIF/SP to redirect the user to the IdP during logout with SAML 2.0 Logout messages: Redirect or HTTP-POST By default set to Redirect SAML 1.1 The SAML 1.1 specifications do not define a message for the SP to send to the IdP when a Federation SSO operation is started. As such, there is no capability to configure OIF/SP on how to affect the start of the Federation SSO flow. OpenID 2.0 OpenID 2.0 defines several extensions that can be used by the SP/RP to affect how the Federation SSO operation will take place: OpenID request: mode: String indicating if the IdP/OP can visually interact with the user checkid_immediate does not allow the IdP/OP to interact with the user checkid_setup allows user interaction By default set to checkid_setup PAPE Extension: max_auth_age : Integer indicating in seconds the maximum amount of time since when the user authenticated at the IdP. If MaxAuthnAge is bigger that the time since when the user last authenticated at the IdP, then the user must be re-challenged. OIF/SP will set this attribute to 0 if the administrator configured ForceAuthn to true, otherwise this attribute won't be set Default missing preferred_auth_policies Contains a Federation Authentication Method Element indicating how the user should be challenged at the IdP By default missing Only specified in the OpenID request if the IdP/OP supports PAPE in XRDS, if OpenID discovery is used. UI Extension Popup mode Boolean indicating the popup mode is enabled for the Federation SSO By default missing Language Preference String containing the preferred language, set based on the browser's language preferences. By default missing Icon: Boolean indicating if the icon feature is enabled. In that case, the IdP/OP would look at the SP/RP XRDS to determine how to retrieve the icon By default missing Only specified in the OpenID request if the IdP/OP supports UI Extenstion in XRDS, if OpenID discovery is used. ForceAuthn and IsPassive WLST Command OIF/SP provides the WLST configureIdPAuthnRequest() command to set: ForceAuthn as a boolean: In a SAML 2.0 AuthnRequest, the ForceAuthn field will be set to true or false In an OpenID 2.0 request, if ForceAuthn in the configuration was set to true, then the max_auth_age field of the PAPE request will be set to 0, otherwise, max_auth_age won't be set IsPassive as a boolean: In a SAML 2.0 AuthnRequest, the IsPassive field will be set to true or false In an OpenID 2.0 request, if IsPassive in the configuration was set to true, then the mode field of the OpenID request will be set to checkid_immediate, otherwise set to checkid_setup Test In this test, OIF/SP is integrated with a remote SAML 2.0 IdP Partner, with the OOTB configuration. Based on this setup, when OIF/SP starts a Federation SSO flow, the following SAML 2.0 AuthnRequest would be generated: <samlp:AuthnRequest ProtocolBinding="urn:oasis:names:tc:SAML:2.0:bindings:HTTP-POST" ID="id-E4BOT7lwbYK56lO57dBaqGUFq01WJSjAHiSR60Q4" Version="2.0" IssueInstant="2014-04-01T21:39:14Z" Destination="https://acme.com/saml20/sso">   <saml:Issuer Format="urn:oasis:names:tc:SAML:2.0:nameid-format:entity">https://sp.com/oam/fed</saml:Issuer>   <samlp:NameIDPolicy AllowCreate="true"/></samlp:AuthnRequest> Let's configure OIF/SP for that IdP Partner, so that the SP will require the IdP to re-challenge the user, even if the user is already authenticated: Enter the WLST environment by executing:$IAM_ORACLE_HOME/common/bin/wlst.sh Connect to the WLS Admin server:connect() Navigate to the Domain Runtime branch:domainRuntime() Execute the configureIdPAuthnRequest() command:configureIdPAuthnRequest(partner="AcmeIdP", forceAuthn="true") Exit the WLST environment:exit() After the changes, the following SAML 2.0 AuthnRequest would be generated: <samlp:AuthnRequest ForceAuthn="true" ProtocolBinding="urn:oasis:names:tc:SAML:2.0:bindings:HTTP-POST" ID="id-E4BOT7lwbYK56lO57dBaqGUFq01WJSjAHiSR60Q4" Version="2.0" IssueInstant="2014-04-01T21:39:14Z" Destination="https://acme.com/saml20/sso">   <saml:Issuer Format="urn:oasis:names:tc:SAML:2.0:nameid-format:entity">https://sp.com/oam/fed</saml:Issuer>   <samlp:NameIDPolicy AllowCreate="true"/></samlp:AuthnRequest> To display or delete the ForceAuthn/IsPassive settings, perform the following operatons: Enter the WLST environment by executing:$IAM_ORACLE_HOME/common/bin/wlst.sh Connect to the WLS Admin server:connect() Navigate to the Domain Runtime branch:domainRuntime() Execute the configureIdPAuthnRequest() command: To display the ForceAuthn/IsPassive settings on the partnerconfigureIdPAuthnRequest(partner="AcmeIdP", displayOnly="true") To delete the ForceAuthn/IsPassive settings from the partnerconfigureIdPAuthnRequest(partner="AcmeIdP", delete="true") Exit the WLST environment:exit() Requested Fed Authn Method In my earlier "Fed Authentication Method Requests in OIF / SP" article, I discussed how OIF/SP could be configured to request a specific Federation Authentication Method from the IdP when starting a Federation SSO operation, by setting elements in the SSO request message. WLST Command The OIF WLST commands that can be used are: setIdPPartnerProfileRequestAuthnMethod() which will configure the requested Federation Authentication Method in a specific IdP Partner Profile, and accepts the following parameters: partnerProfile: name of the IdP Partner Profile authnMethod: the Federation Authentication Method to request displayOnly: an optional parameter indicating if the method should display the current requested Federation Authentication Method instead of setting it delete: an optional parameter indicating if the method should delete the current requested Federation Authentication Method instead of setting it setIdPPartnerRequestAuthnMethod() which will configure the specified IdP Partner entry with the requested Federation Authentication Method, and accepts the following parameters: partner: name of the IdP Partner authnMethod: the Federation Authentication Method to request displayOnly: an optional parameter indicating if the method should display the current requested Federation Authentication Method instead of setting it delete: an optional parameter indicating if the method should delete the current requested Federation Authentication Method instead of setting it This applies to SAML 2.0 and OpenID 2.0 protocols. See the "Fed Authentication Method Requests in OIF / SP" article for more information. Test In this test, OIF/SP is integrated with a remote SAML 2.0 IdP Partner, with the OOTB configuration. Based on this setup, when OIF/SP starts a Federation SSO flow, the following SAML 2.0 AuthnRequest would be generated: <samlp:AuthnRequest ProtocolBinding="urn:oasis:names:tc:SAML:2.0:bindings:HTTP-POST" ID="id-E4BOT7lwbYK56lO57dBaqGUFq01WJSjAHiSR60Q4" Version="2.0" IssueInstant="2014-04-01T21:39:14Z" Destination="https://acme.com/saml20/sso">   <saml:Issuer Format="urn:oasis:names:tc:SAML:2.0:nameid-format:entity">https://sp.com/oam/fed</saml:Issuer>   <samlp:NameIDPolicy AllowCreate="true"/></samlp:AuthnRequest> Let's configure OIF/SP for that IdP Partner, so that the SP will request the IdP to use a mechanism mapped to the urn:oasis:names:tc:SAML:2.0:ac:classes:X509 Federation Authentication Method to authenticate the user: Enter the WLST environment by executing:$IAM_ORACLE_HOME/common/bin/wlst.sh Connect to the WLS Admin server:connect() Navigate to the Domain Runtime branch:domainRuntime() Execute the setIdPPartnerRequestAuthnMethod() command:setIdPPartnerRequestAuthnMethod("AcmeIdP", "urn:oasis:names:tc:SAML:2.0:ac:classes:X509") Exit the WLST environment:exit() After the changes, the following SAML 2.0 AuthnRequest would be generated: <samlp:AuthnRequest ProtocolBinding="urn:oasis:names:tc:SAML:2.0:bindings:HTTP-POST" ID="id-E4BOT7lwbYK56lO57dBaqGUFq01WJSjAHiSR60Q4" Version="2.0" IssueInstant="2014-04-01T21:39:14Z" Destination="https://acme.com/saml20/sso">   <saml:Issuer Format="urn:oasis:names:tc:SAML:2.0:nameid-format:entity">https://sp.com/oam/fed</saml:Issuer>   <samlp:NameIDPolicy AllowCreate="true"/>   <samlp:RequestedAuthnContext Comparison="minimum">      <saml:AuthnContextClassRef xmlns:saml="urn:oasis:names:tc:SAML:2.0:assertion">         urn:oasis:names:tc:SAML:2.0:ac:classes:X509      </saml:AuthnContextClassRef>   </samlp:RequestedAuthnContext></samlp:AuthnRequest> NameID Format The SAML 2.0 protocol allows for the SP to request from the IdP a specific NameID format to be used when the Assertion is issued by the IdP. Note: SAML 1.1 and OpenID 2.0 do not provide such a mechanism Configuring OIF The administrator can configure OIF/SP to request a NameID format in the SAML 2.0 AuthnRequest via: The OAM Administration Console, in the IdP Partner entry The OIF WLST setIdPPartnerNameIDFormat() command that will modify the IdP Partner configuration OAM Administration Console To configure the requested NameID format via the OAM Administration Console, perform the following steps: Go to the OAM Administration Console: http(s)://oam-admin-host:oam-admin-port/oamconsole Navigate to Identity Federation -> Service Provider Administration Open the IdP Partner you wish to modify In the Authentication Request NameID Format dropdown box with one of the values None The NameID format will be set Default Email Address The NameID format will be set urn:oasis:names:tc:SAML:1.1:nameid-format:emailAddress X.509 Subject The NameID format will be set urn:oasis:names:tc:SAML:1.1:nameid-format:X509SubjectName Windows Name Qualifier The NameID format will be set urn:oasis:names:tc:SAML:1.1:nameid-format:WindowsDomainQualifiedName Kerberos The NameID format will be set urn:oasis:names:tc:SAML:2.0:nameid-format:kerberos Transient The NameID format will be set urn:oasis:names:tc:SAML:2.0:nameid-format:transient Unspecified The NameID format will be set urn:oasis:names:tc:SAML:1.1:nameid-format:unspecified Custom In this case, a field would appear allowing the administrator to indicate the custom NameID format to use The NameID format will be set to the specified format Persistent The NameID format will be set urn:oasis:names:tc:SAML:2.0:nameid-format:persistent I selected Email Address in this example Save WLST Command To configure the requested NameID format via the OIF WLST setIdPPartnerNameIDFormat() command, perform the following steps: Enter the WLST environment by executing:$IAM_ORACLE_HOME/common/bin/wlst.sh Connect to the WLS Admin server:connect() Navigate to the Domain Runtime branch:domainRuntime() Execute the setIdPPartnerNameIDFormat() command:setIdPPartnerNameIDFormat("PARTNER", "FORMAT", customFormat="CUSTOM") Replace PARTNER with the IdP Partner name Replace FORMAT with one of the following: orafed-none The NameID format will be set Default orafed-emailaddress The NameID format will be set urn:oasis:names:tc:SAML:1.1:nameid-format:emailAddress orafed-x509 The NameID format will be set urn:oasis:names:tc:SAML:1.1:nameid-format:X509SubjectName orafed-windowsnamequalifier The NameID format will be set urn:oasis:names:tc:SAML:1.1:nameid-format:WindowsDomainQualifiedName orafed-kerberos The NameID format will be set urn:oasis:names:tc:SAML:2.0:nameid-format:kerberos orafed-transient The NameID format will be set urn:oasis:names:tc:SAML:2.0:nameid-format:transient orafed-unspecified The NameID format will be set urn:oasis:names:tc:SAML:1.1:nameid-format:unspecified orafed-custom In this case, a field would appear allowing the administrator to indicate the custom NameID format to use The NameID format will be set to the specified format orafed-persistent The NameID format will be set urn:oasis:names:tc:SAML:2.0:nameid-format:persistent customFormat will need to be set if the FORMAT is set to orafed-custom An example would be:setIdPPartnerNameIDFormat("AcmeIdP", "orafed-emailaddress") Exit the WLST environment:exit() Test In this test, OIF/SP is integrated with a remote SAML 2.0 IdP Partner, with the OOTB configuration. Based on this setup, when OIF/SP starts a Federation SSO flow, the following SAML 2.0 AuthnRequest would be generated: <samlp:AuthnRequest ProtocolBinding="urn:oasis:names:tc:SAML:2.0:bindings:HTTP-POST" ID="id-E4BOT7lwbYK56lO57dBaqGUFq01WJSjAHiSR60Q4" Version="2.0" IssueInstant="2014-04-01T21:39:14Z" Destination="https://acme.com/saml20/sso">   <saml:Issuer Format="urn:oasis:names:tc:SAML:2.0:nameid-format:entity">https://sp.com/oam/fed</saml:Issuer> <samlp:NameIDPolicy AllowCreate="true"/></samlp:AuthnRequest> After the changes performed either via the OAM Administration Console or via the OIF WLST setIdPPartnerNameIDFormat() command where Email Address would be requested as the NameID Format, the following SAML 2.0 AuthnRequest would be generated: <samlp:AuthnRequest ForceAuthn="false" IsPassive="false" ProtocolBinding="urn:oasis:names:tc:SAML:2.0:bindings:HTTP-POST" ID="id-E4BOT7lwbYK56lO57dBaqGUFq01WJSjAHiSR60Q4" Version="2.0" IssueInstant="2014-04-01T21:39:14Z" Destination="https://acme.com/saml20/sso">   <saml:Issuer Format="urn:oasis:names:tc:SAML:2.0:nameid-format:entity">https://sp.com/oam/fed</saml:Issuer> <samlp:NameIDPolicy Format="urn:oasis:names:tc:SAML:1.1:nameid-format:emailAddress" AllowCreate="true"/></samlp:AuthnRequest> Protocol Binding The SAML 2.0 specifications define a way for the SP to request which binding should be used by the IdP to redirect the user to the SP with the SAML 2.0 Assertion: the ProtocolBinding attribute indicates the binding the IdP should use. It is set to: Either urn:oasis:names:tc:SAML:2.0:bindings:HTTP-POST for HTTP-POST Or urn:oasis:names:tc:SAML:2.0:bindings:Artifact for Artifact The SAML 2.0 specifications also define different ways to redirect the user from the SP to the IdP with the SAML 2.0 AuthnRequest message, as the SP can send the message: Either via HTTP Redirect Or HTTP POST (Other bindings can theoretically be used such as Artifact, but these are not used in practice) Configuring OIF OIF can be configured: Via the OAM Administration Console or the OIF WLST configureSAMLBinding() command to set the Assertion Response binding to be used Via the OIF WLST configureSAMLBinding() command to indicate how the SAML AuthnRequest message should be sent Note: the binding for sending the SAML 2.0 AuthnRequest message will also be used to send the SAML 2.0 LogoutRequest and LogoutResponse messages. OAM Administration Console To configure the SSO Response/Assertion Binding via the OAM Administration Console, perform the following steps: Go to the OAM Administration Console: http(s)://oam-admin-host:oam-admin-port/oamconsole Navigate to Identity Federation -> Service Provider Administration Open the IdP Partner you wish to modify Check the "HTTP POST SSO Response Binding" box to request the IdP to return the SSO Response via HTTP POST, otherwise uncheck it to request artifact Save WLST Command To configure the SSO Response/Assertion Binding as well as the AuthnRequest Binding via the OIF WLST configureSAMLBinding() command, perform the following steps: Enter the WLST environment by executing:$IAM_ORACLE_HOME/common/bin/wlst.sh Connect to the WLS Admin server:connect() Navigate to the Domain Runtime branch:domainRuntime() Execute the configureSAMLBinding() command:configureSAMLBinding("PARTNER", "PARTNER_TYPE", binding, ssoResponseBinding="httppost") Replace PARTNER with the Partner name Replace PARTNER_TYPE with the Partner type (idp or sp) Replace binding with the binding to be used to send the AuthnRequest and LogoutRequest/LogoutResponse messages (should be httpredirect in most case; default) httppost for HTTP-POST binding httpredirect for HTTP-Redirect binding Specify optionally ssoResponseBinding to indicate how the SSO Assertion should be sent back httppost for HTTP-POST binding artifactfor for Artifact binding An example would be:configureSAMLBinding("AcmeIdP", "idp", "httpredirect", ssoResponseBinding="httppost") Exit the WLST environment:exit() Test In this test, OIF/SP is integrated with a remote SAML 2.0 IdP Partner, with the OOTB configuration which requests HTTP-POST from the IdP to send the SSO Assertion. Based on this setup, when OIF/SP starts a Federation SSO flow, the following SAML 2.0 AuthnRequest would be generated: <samlp:AuthnRequest ProtocolBinding="urn:oasis:names:tc:SAML:2.0:bindings:HTTP-POST" ID="id-E4BOT7lwbYK56lO57dBaqGUFq01WJSjAHiSR60Q4" Version="2.0" IssueInstant="2014-04-01T21:39:14Z" Destination="https://acme.com/saml20/sso">   <saml:Issuer Format="urn:oasis:names:tc:SAML:2.0:nameid-format:entity">https://sp.com/oam/fed</saml:Issuer>   <samlp:NameIDPolicy AllowCreate="true"/></samlp:AuthnRequest> In the next article, I will cover the various crypto configuration properties in OIF that are used to affect the Federation SSO exchanges.Cheers,Damien Carru

    Read the article

< Previous Page | 158 159 160 161 162 163 164 165 166 167 168 169  | Next Page >