Search Results

Search found 17958 results on 719 pages for 'local delivery'.

Page 168/719 | < Previous Page | 164 165 166 167 168 169 170 171 172 173 174 175  | Next Page >

  • Localize WiX installer which uses the Firewall extension

    - by tronda
    I've got a WiX installer project which uses MSBuild to generate the MSI file. The WXS file includes the WiX firewall extension: xmlns:fire="http://schemas.microsoft.com/wix/FirewallExtension" I've defined two cultures in the MSBuild file with the following definition: <PropertyGroup> ... <Cultures>en-us;no-no</Cultures> </PropertyGroup> I've also added the translated resources: <ItemGroup> <EmbeddedResource Include="lang\Firewall_no-no.wxl" /> <EmbeddedResource Include="lang\WixUI_no-no.wxl" /> </ItemGroup> These represents translation to Norwegian for the Firewall extension and the WixUI extension. When I run the build it succeeds with the en-us part, but the no-no part fails with the following error messages: C:\delivery\Dev\wix30_public\src\ext\FirewallExtension\wixlib\FirewallExtension.wxs(19): error LGHT0102: The localization variable !(loc.WixSchedFirewallExceptionsInstall) is unknown. Please ensure the variable is defined. .... Couple of issues: I don't know where the C:\delivery directory comes from. I don't have such a directory. The localization variables referenced in the error message have been translated in the Firewall_no-no.wxl file. When I run MSBuild with more detailed information I see the following output right before the error message: Task "Light" Command: C:\Program Files (x86)\Windows Installer XML v3\bin\Light.exe -cultures:no-no -ext "C:\Program Files (x86)\Windows Installer XML v3\bin\WixUIExtension.dll" -ext "C:\Program Files (x86)\Windows I nstaller XML v3\bin\WixUtilExtension.dll" -ext "C:\Program Files (x86)\Windows Installer XML v3\bin\WixFirewallExtension.dll" -loc lang\Firewall_no-no.wxl -loc lang\WixUI_no-no.wxl -out F:\Projects\MyProd\MyProj\Installer\bin\Debug\no-no\MyInstaller.msi -pdbout F:\Projects\MyProd\MyProj\Installer\bin\Debug\no-no\MyInstaller.wixpdb obj\Debug\MyProj.wixobj As the details show, the MSBuild task results in having two -loc parameters to the Light executable. Not sure if that would be the reason for this problem. Any ideas on how to solve this?

    Read the article

  • Objective-C NSArray NEWBIE Question:

    - by clearbrian
    Hi I have a weird problems with NSArray where some of the members of the objects in my array are going out of scope but not the others: I have a simple object called Section. It has 3 members. @interface Section : NSObject { NSNumber *section_Id; NSNumber *routeId; NSString *startLocationName; } @property(nonatomic,retain) NSNumber *section_Id; @property(nonatomic,retain) NSNumber *routeId; @property(nonatomic,retain) NSString *startLocationName; @end @implementation Section @synthesize section_Id; @synthesize routeId; @synthesize startLocationName; //Some static finder methods to get list of Sections from the db + (NSMutableArray *) findAllSections:{ - (void)dealloc { [section_Id release]; [routeId release]; [startLocationName release]; [super dealloc]; } @end I fill it from a database in a method called findAllSection self.sections = [Section findAllSections]; In find all sections I create some local variables fill them with data from db. NSNumber *secId = [NSNumber numberWithInt:id_section]; NSNumber *rteId = [NSNumber numberWithInt:id_route]; NSString *startName = @""; Then create a new Section and store these local variable's data in the Section Section *section = [[Section alloc] init]; section.section_Id = secId; section.routeId = rteId; section.startLocationName = startName; Then I add the section to the array [sectionsArray addObject:section]; Then I clean up, releasing local variables and the section I added to the array [secId release]; [rteId release]; [startName release]; [locEnd_name release]; [section release]; In a loop repeat for all Sections (release local variables and section is done in every loop) The method returns and I check the array and all the Sections are there. I cant seem to dig further down to see the values of the Section objects in the array (is this possible) Later I try and retrieve one of the Sections I get it from the array Section * section = [self.sections objectAtIndex:row]; Then check the value NSLog(@" SECTION SELECTED:%@",section.section_Id); BUT call to section.section_Id crashed as section.section_Id is out of scope. I check the other members of this Section object and theyre ok. After some trial and error I find that by commenting out the release of the member variable the object is OK. //[secId release]; [rteId release]; [startName release]; [locEnd_name release]; [section release]; My questions are: Am I cleaning up ok? Should I release the object added to an array and the local variable in the function? Is my dealloc ok in Section? Does this code look ok and should I be looking elsewhere for the problem? I'm not doing anything complicated just filling array from DB use it in Table Cell. If its a stupid mistake then tell me (I did put NEWBIE on the question so dont be shocked it was asked) I can comment out the release but would prefer to know why or if code looks ok then ill need further digging. the only place that secId is released is in the dealloc. Thanks

    Read the article

  • Javascript Closures - What are the negatives?

    - by vol7ron
    Question: There seem to be many benefits to Closures, but what are the negatives (memory leakage? obfuscation problems? bandwidth increasage?)? Additionally, is my understanding of Closures correct? Finally, once closures are created, can they be destroyed? I've been reading a little bit about Javascript Closures. I hope someone a little more knowledgeable will guide my assertions, correcting me where wrong. Benefits of Closures: Encapsulate the variables to a local scope, by using an internal function. The anonymity of the function is insignificant. What I've found helpful is to do some basic testing, regarding local/global scope: <script type="text/javascript"> var global_text = ""; var global_count = 0; var global_num1 = 10; var global_num2 = 20; var global_num3 = 30; function outerFunc() { var local_count = local_count || 0; alert("global_num1: " + global_num1); // global_num1: undefined var global_num1 = global_num1 || 0; alert("global_num1: " + global_num1); // global_num1: 0 alert("global_num2: " + global_num2); // global_num2: 20 global_num2 = global_num2 || 0; // (notice) no definition with 'var' alert("global_num2: " + global_num2); // global_num2: 20 global_num2 = 0; alert("local_count: " + local_count); // local_count: 0 function output() { global_num3++; alert("local_count: " + local_count + "\n" + "global_count: " + global_count + "\n" + "global_text: " + global_text ); local_count++; } local_count++; global_count++; return output; } var myFunc = outerFunc(); myFunc(); /* Outputs: ********************** * local_count: 1 * global_count: 1 * global_text: **********************/ global_text = "global"; myFunc(); /* Outputs: ********************** * local_count: 2 * global_count: 1 * global_text: global **********************/ var local_count = 100; myFunc(); /* Outputs: ********************** * local_count: 3 * global_count: 1 * global_text: global **********************/ alert("global_num1: " + global_num1); // global_num1: 10 alert("global_num2: " + global_num2); // global_num2: 0 alert("global_num3: " + global_num3); // global_num3: 33 </script> Interesting things I took out of it: The alerts in outerFunc are only called once, which is when the outerFunc call is assigned to myFunc (myFunc = outerFunc()). This assignment seems to keep the outerFunc open, in what I would like to call a persistent state. Everytime myFunc is called, the return is executed. In this case, the return is the internal function. Something really interesting is the localization that occurs when defining local variables. Notice the difference in the first alert between global_num1 and global_num2, even before the variable is trying to be created, global_num1 is considered undefined because the 'var' was used to signify a local variable to that function. -- This has been talked about before, in the order of operation for the Javascript engine, it's just nice to see this put to work. Globals can still be used, but local variables will override them. Notice before the third myFunc call, a global variable called local_count is created, but it as no effect on the internal function, which has a variable that goes by the same name. Conversely, each function call has the ability to modify global variables, as noticed by global_var3. Post Thoughts: Even though the code is straightforward, it is cluttered by alerts for you guys, so you can plug and play. I know there are other examples of closures, many of which use anonymous functions in combination with looping structures, but I think this is good for a 101-starter course to see the effects. The one thing I'm concerned with is the negative impact closures will have on memory. Because it keeps the function environment open, it is also keeping those variables stored in memory, which may/may not have performance implications, especially regarding DOM traversals and garbage collection. I'm also not sure what kind of role this will play in terms of memory leakage and I'm not sure if the closure can be removed from memory by a simple "delete myFunc;." Hope this helps someone, vol7ron

    Read the article

  • Trying get dynamic content hole-punched through Magento's Full Page Cache

    - by rlflow
    I am using Magento Enterprise 1.10.1.1 and need to get some dynamic content on our product pages. I am inserting the current time in a block to quickly see if it is working, but can't seem to get through full page cache. I have tried a variety of implementations found here: http://tweetorials.tumblr.com/post/10160075026/ee-full-page-cache-hole-punching http://oggettoweb.com/blog/customizations-compatible-magento-full-page-cache/ http://magentophp.blogspot.com/2011/02/magento-enterprise-full-page-caching.html (http://www.exploremagento.com/magento/simple-custom-module.php - custom module) Any solutions, thoughts, comments, advice is welcome. here is my code: app/code/local/Fido/Example/etc/config.xml <?xml version="1.0"?> <config> <modules> <Fido_Example> <version>0.1.0</version> </Fido_Example> </modules> <global> <blocks> <fido_example> <class>Fido_Example_Block</class> </fido_example> </blocks> </global> </config> app/code/local/Fido/Example/etc/cache.xml <?xml version="1.0" encoding="UTF-8"?> <config> <placeholders> <fido_example> <block>fido_example/view</block> <name>example</name> <placeholder>CACHE_TEST</placeholder> <container>Fido_Example_Model_Container_Cachetest</container> <cache_lifetime>86400</cache_lifetime> </fido_example> </placeholders> </config> app/code/local/Fido/Example/Block/View.php <?php /** * Example View block * * @codepool Local * @category Fido * @package Fido_Example * @module Example */ class Fido_Example_Block_View extends Mage_Core_Block_Template { private $message; private $att; protected function createMessage($msg) { $this->message = $msg; } public function receiveMessage() { if($this->message != '') { return $this->message; } else { $this->createMessage('Hello World'); return $this->message; } } protected function _toHtml() { $html = parent::_toHtml(); if($this->att = $this->getMyCustom() && $this->getMyCustom() != '') { $html .= '<br />'.$this->att; } else { $now = date('m-d-Y h:i:s A'); $html .= $now; $html .= '<br />' ; } return $html; } } app/code/local/Fido/Example/Model/Container/Cachetest.php <?php class Fido_Example_Model_Container_Cachetest extends Enterprise_PageCache_Model_Container_Abstract { protected function _getCacheId() { return 'HOMEPAGE_PRODUCTS' . md5($this->_placeholder->getAttribute('cache_id') . $this->_getIdentifier()); } protected function _renderBlock() { $blockClass = $this->_placeholder->getAttribute('block'); $template = $this->_placeholder->getAttribute('template'); $block = new $blockClass; $block->setTemplate($template); return $block->toHtml(); } protected function _saveCache($data, $id, $tags = array(), $lifetime = null) { return false; } } app/design/frontend/enterprise/[mytheme]/template/example/view.phtml <?php /** * Fido view template * * @see Fido_Example_Block_View * */ ?> <div> <?php echo $this->receiveMessage(); ?> </span> </div> snippet from app/design/frontend/enterprise/[mytheme]/layout/catalog.xml <reference name="content"> <block type="catalog/product_view" name="product.info" template="catalog/product/view.phtml"> <block type="fido_example/view" name="product.info.example" as="example" template="example/view.phtml" />

    Read the article

  • Inheritance of templates in WPF

    - by Alxandr
    I'm trying to make sure that every child of a given element (MPF.MWindow) gets custom templates. For instance, the button should get the template defined in resMButton.xaml. As of now I'm using the following code on: (resMWindow.xaml) <ResourceDictionary xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:local="clr-namespace:MPF"> <Style x:Key="SystemKeyAnimations" TargetType="{x:Type Button}"> <Setter Property="Opacity" Value="0.5" /> <Setter Property="Background" Value="Transparent" /> <Style.Triggers> <EventTrigger RoutedEvent="Mouse.MouseEnter"> <BeginStoryboard> <Storyboard> <DoubleAnimationUsingKeyFrames BeginTime="00:00:00" Storyboard.TargetProperty="Opacity"> <SplineDoubleKeyFrame KeyTime="00:00:00.2" Value="1.0" /> </DoubleAnimationUsingKeyFrames> </Storyboard> </BeginStoryboard> </EventTrigger> <EventTrigger RoutedEvent="Mouse.MouseLeave"> <BeginStoryboard> <Storyboard> <DoubleAnimationUsingKeyFrames BeginTime="00:00:00" Storyboard.TargetProperty="Opacity"> <SplineDoubleKeyFrame KeyTime="00:00:00.2" Value="0.5" /> </DoubleAnimationUsingKeyFrames> </Storyboard> </BeginStoryboard> </EventTrigger> </Style.Triggers> </Style> <Style TargetType="{x:Type local:MWindow}"> <!-- Remove default frame appearance --> <Setter Property="WindowStyle" Value="None" /> <Setter Property="AllowsTransparency" Value="True" /> <Setter Property="Background" Value="Transparent" /> <Setter Property="Template"> <Setter.Value> <ControlTemplate TargetType="{x:Type local:MWindow}"> <Border Background="{TemplateBinding Background}" BorderBrush="{TemplateBinding BorderBrush}" BorderThickness="{TemplateBinding BorderThickness}" x:Name="ChromeBorder"> <Grid> <Grid.ColumnDefinitions> <ColumnDefinition Width="4" /> <ColumnDefinition /> <ColumnDefinition Width="4" /> </Grid.ColumnDefinitions> <Grid.RowDefinitions> <RowDefinition Height="4" /> <RowDefinition /> <RowDefinition Height="4" /> </Grid.RowDefinitions> <Thumb Grid.Row="0" Grid.Column="1" x:Name="TopThumb" Cursor="SizeNS" BorderThickness="4" BorderBrush="Transparent" /> <Thumb Grid.Row="2" Grid.Column="1" x:Name="BottomThumb" Cursor="SizeNS" BorderThickness="4" BorderBrush="Transparent" /> <Thumb Grid.Row="1" Grid.Column="0" x:Name="LeftThumb" Cursor="SizeWE" BorderThickness="4" BorderBrush="Transparent" /> <Thumb Grid.Row="1" Grid.Column="2" x:Name="RightThumb" Cursor="SizeWE" BorderThickness="4" BorderBrush="Transparent" /> <Thumb Grid.Row="0" Grid.Column="0" x:Name="TopLeftThumb" Cursor="SizeNWSE" BorderThickness="5" BorderBrush="Transparent" /> <Thumb Grid.Row="0" Grid.Column="2" x:Name="TopRightThumb" Cursor="SizeNESW" BorderThickness="5" BorderBrush="Transparent" /> <Thumb Grid.Row="2" Grid.Column="0" x:Name="BottomLeftThumb" Cursor="SizeNESW" BorderThickness="5" BorderBrush="Transparent" /> <Thumb Grid.Row="2" Grid.Column="2" x:Name="BottomRightThumb" Cursor="SizeNWSE" BorderThickness="5" BorderBrush="Transparent" /> <Grid Grid.Row="1" Grid.Column="1"> <Grid.RowDefinitions> <RowDefinition Height="20" /> <RowDefinition /> </Grid.RowDefinitions> <Grid> <Grid.ColumnDefinitions> <ColumnDefinition /> <ColumnDefinition Width="Auto" /> </Grid.ColumnDefinitions> <StackPanel Orientation="Horizontal" Grid.Column="1"> <Button Command="local:WindowCommands.Minimize" Style="{StaticResource ResourceKey=SystemKeyAnimations}"> <Button.Template> <ControlTemplate> <Canvas Width="10" Height="10" Margin="5" Background="Transparent"> <Line X1="0" X2="10" Y1="5" Y2="5" Stroke="White" StrokeThickness="2" /> </Canvas> </ControlTemplate> </Button.Template> </Button> <Button Command="local:WindowCommands.Maximize" x:Name="MaximizeButton" Style="{StaticResource ResourceKey=SystemKeyAnimations}"> <Button.Template> <ControlTemplate> <Canvas Width="10" Height="10" Margin="5" Background="Transparent"> <Rectangle Width="10" Height="10" Stroke="White" StrokeThickness="2" /> </Canvas> </ControlTemplate> </Button.Template> </Button> <Button Command="ApplicationCommands.Close" Style="{StaticResource ResourceKey=SystemKeyAnimations}"> <Button.Template> <ControlTemplate> <Canvas Width="10" Height="10" Margin="5" Background="Transparent"> <Line X1="0" X2="10" Y1="0" Y2="10" Stroke="White" StrokeThickness="2" /> <Line X1="10" X2="0" Y1="0" Y2="10" Stroke="White" StrokeThickness="2" /> </Canvas> </ControlTemplate> </Button.Template> </Button> </StackPanel> <ContentControl x:Name="TitleContentControl"> <TextBlock Text="{TemplateBinding Title}" Foreground="DarkGray" Margin="5,0" /> </ContentControl> </Grid> <ContentPresenter Content="{TemplateBinding Content}" Grid.Row="1"> <ContentPresenter.Resources> <ResourceDictionary> <ResourceDictionary.MergedDictionaries> <ResourceDictionary Source="/MPF;component/Themes/resMWindowContent.xaml" /> </ResourceDictionary.MergedDictionaries> </ResourceDictionary> </ContentPresenter.Resources> </ContentPresenter> </Grid> </Grid> </Border> </ControlTemplate> </Setter.Value> </Setter> </Style> </ResourceDictionary> As you can see during the ContentPresenter which gets the content of the window I merge in a dicrionary called resMWindowContent.xaml. The resMWindowContent.xaml looks as following: <ResourceDictionary xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:local="clr-namespace:MPF"> <ResourceDictionary.MergedDictionaries> <ResourceDictionary Source="/MPF;component/Themes/resMButton.xaml" /> </ResourceDictionary.MergedDictionaries> </ResourceDictionary> It simply merges in the resMButton.xaml dictionary (this is done because in the feature I will have MTextBox, mList... and I want to separate them). The resMButton.xaml looks as following: <ResourceDictionary xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:local="clr-namespace:MPF"> <Style TargetType="{x:Type Button}"> <Setter Property="Template"> <Setter.Value> <ControlTemplate TargetType="{x:Type Button}"> <Grid Background="Transparent"> <Rectangle Stroke="{TemplateBinding BorderBrush}" StrokeThickness="{TemplateBinding BorderThickness}" Fill="{TemplateBinding Background}" /> <ContentPresenter Content="{TemplateBinding Content}" Margin="3" /> </Grid> </ControlTemplate> </Setter.Value> </Setter> </Style> </ResourceDictionary> A simple template drawing a square button. However, it isn't applied at all. My buttons remain normal, and I don't understand what I'm doing wrong. I just want every button inside the MWindow to get a special style (and in time every textbox and so forth). How do I achieve this? One note though: It's important that the styles doesn't apply to elements outside an MWindow.

    Read the article

  • Installing vim7.2 on Solaris Sparc 10 as non-root

    - by Tobbe
    I'm trying to install vim to $HOME/bin by compiling the sources. ./configure --prefix=$home/bin seems to work, but when running make I get: > make Starting make in the src directory. If there are problems, cd to the src directory and run make there cd src && make first gcc -c -I. -Iproto -DHAVE_CONFIG_H -DFEAT_GUI_GTK -I/usr/include/gtk-2.0 -I/usr/lib/gtk-2.0/include -I/usr/include/atk-1.0 -I/usr/include/pango-1.0 -I/usr/openwin/include -I/usr/sfw/include -I/usr/sfw/include/freetype2 -I/usr/include/glib-2.0 -I/usr/lib/glib-2.0/include -g -O2 -I/usr/openwin/include -o objects/buffer.o buffer.c In file included from buffer.c:28: vim.h:41: error: syntax error before ':' token In file included from os_unix.h:29, from vim.h:245, from buffer.c:28: /usr/include/sys/stat.h:251: error: syntax error before "blksize_t" /usr/include/sys/stat.h:255: error: syntax error before '}' token /usr/include/sys/stat.h:309: error: syntax error before "blksize_t" /usr/include/sys/stat.h:310: error: conflicting types for 'st_blocks' /usr/include/sys/stat.h:252: error: previous declaration of 'st_blocks' was here /usr/include/sys/stat.h:313: error: syntax error before '}' token In file included from /opt/local/bin/../lib/gcc/sparc-sun-solaris2.6/3.4.6/include/sys/signal.h:132, from /usr/include/signal.h:26, from os_unix.h:163, from vim.h:245, from buffer.c:28: /usr/include/sys/siginfo.h:259: error: syntax error before "ctid_t" /usr/include/sys/siginfo.h:292: error: syntax error before '}' token /usr/include/sys/siginfo.h:294: error: syntax error before '}' token /usr/include/sys/siginfo.h:390: error: syntax error before "ctid_t" /usr/include/sys/siginfo.h:398: error: conflicting types for '__fault' /usr/include/sys/siginfo.h:267: error: previous declaration of '__fault' was here /usr/include/sys/siginfo.h:404: error: conflicting types for '__file' /usr/include/sys/siginfo.h:273: error: previous declaration of '__file' was here /usr/include/sys/siginfo.h:420: error: conflicting types for '__prof' /usr/include/sys/siginfo.h:287: error: previous declaration of '__prof' was here /usr/include/sys/siginfo.h:424: error: conflicting types for '__rctl' /usr/include/sys/siginfo.h:291: error: previous declaration of '__rctl' was here /usr/include/sys/siginfo.h:426: error: syntax error before '}' token /usr/include/sys/siginfo.h:428: error: syntax error before '}' token /usr/include/sys/siginfo.h:432: error: syntax error before "k_siginfo_t" /usr/include/sys/siginfo.h:437: error: syntax error before '}' token In file included from /usr/include/signal.h:26, from os_unix.h:163, from vim.h:245, from buffer.c:28: /opt/local/bin/../lib/gcc/sparc-sun-solaris2.6/3.4.6/include/sys/signal.h:173: error: syntax error before "siginfo_t" In file included from os_unix.h:163, from vim.h:245, from buffer.c:28: /usr/include/signal.h:111: error: syntax error before "siginfo_t" /usr/include/signal.h:113: error: syntax error before "siginfo_t" buffer.c: In function `buflist_new': buffer.c:1502: error: storage size of 'st' isn't known buffer.c: In function `buflist_findname': buffer.c:1989: error: storage size of 'st' isn't known buffer.c: In function `setfname': buffer.c:2578: error: storage size of 'st' isn't known buffer.c: In function `otherfile_buf': buffer.c:2836: error: storage size of 'st' isn't known buffer.c: In function `buf_setino': buffer.c:2874: error: storage size of 'st' isn't known buffer.c: In function `buf_same_ino': buffer.c:2894: error: dereferencing pointer to incomplete type buffer.c:2895: error: dereferencing pointer to incomplete type *** Error code 1 make: Fatal error: Command failed for target `objects/buffer.o' Current working directory /home/xluntor/vim72/src *** Error code 1 make: Fatal error: Command failed for target `first' How do I fix the make errors? Or is there another way to install vim as non-root? Thanks in advance EDIT: I took a look at the google groups link Sarah posted. The "Compiling Vim" page linked from there was for Linux, so the commands doesn't even work on Solars. But it did hint at logging the output of ./configure to a file, so I did that. Here it is: ./configure output removed. New version further down. Does anyone spot anything critical missing? EDIT 2: So I downloaded the vim package from sunfreeware. I couldn't just install it, since I don't have root privileges, but I was able to extract the package file. This was the file structure in it: `-- SMCvim `-- reloc |-- bin |-- doc | `-- vim `-- share |-- man | `-- man1 `-- vim `-- vim72 |-- autoload | `-- xml |-- colors |-- compiler |-- doc |-- ftplugin |-- indent |-- keymap |-- lang |-- macros | |-- hanoi | |-- life | |-- maze | `-- urm |-- plugin |-- print |-- spell |-- syntax |-- tools `-- tutor I moved the three files (vim, vimtutor, xdd) in SMCvim/reloc/bin to $HOME/bin, so now I can finally run $HOME/bin/vim! But where do I put the "share" directory and its content? EDIT 3: It might also be worth noting that there already exists an install of vim on the system, but it is broken. When I try to run it I get: ld.so.1: vim: fatal: libgtk-1.2.so.0: open failed: No such file or directory "which vim" outputs /opt/local/bin/vim EDIT 4: Trying to compile this on Solaris 10. uname -a SunOS ws005-22 5.10 Generic_141414-10 sun4u sparc SUNW,SPARC-Enterprise New ./configure output: ./configure --prefix=$home/bin ac_cv_sizeof_int=8 --enable-rubyinterp configure: loading cache auto/config.cache checking whether make sets $(MAKE)... yes checking for gcc... gcc checking for C compiler default output file name... a.out checking whether the C compiler works... yes checking whether we are cross compiling... no checking for suffix of executables... checking for suffix of object files... o checking whether we are using the GNU C compiler... yes checking whether gcc accepts -g... yes checking for gcc option to accept ISO C89... unsupported checking how to run the C preprocessor... gcc -E checking for grep that handles long lines and -e... /usr/sfw/bin/ggrep checking for egrep... /usr/sfw/bin/ggrep -E checking for library containing strerror... none required checking for gawk... gawk checking for strip... strip checking for ANSI C header files... yes checking for sys/wait.h that is POSIX.1 compatible... no configure: checking for buggy tools... checking for BeOS... no checking for QNX... no checking for Darwin (Mac OS X)... no checking --with-local-dir argument... Defaulting to /usr/local checking --with-vim-name argument... Defaulting to vim checking --with-ex-name argument... Defaulting to ex checking --with-view-name argument... Defaulting to view checking --with-global-runtime argument... no checking --with-modified-by argument... no checking if character set is EBCDIC... no checking --disable-selinux argument... no checking for is_selinux_enabled in -lselinux... no checking --with-features argument... Defaulting to normal checking --with-compiledby argument... no checking --disable-xsmp argument... no checking --disable-xsmp-interact argument... no checking --enable-mzschemeinterp argument... no checking --enable-perlinterp argument... no checking --enable-pythoninterp argument... no checking --enable-tclinterp argument... no checking --enable-rubyinterp argument... yes checking for ruby... /opt/sfw/bin/ruby checking Ruby version... OK checking Ruby header files... /opt/sfw/lib/ruby/1.6/sparc-solaris2.10 checking --enable-cscope argument... no checking --enable-workshop argument... no checking --disable-netbeans argument... no checking for socket in -lsocket... yes checking for gethostbyname in -lnsl... yes checking whether compiling netbeans integration is possible... no checking --enable-sniff argument... no checking --enable-multibyte argument... no checking --enable-hangulinput argument... no checking --enable-xim argument... defaulting to auto checking --enable-fontset argument... no checking for xmkmf... /usr/openwin/bin/xmkmf checking for X... libraries /usr/openwin/lib, headers /usr/openwin/include checking whether -R must be followed by a space... no checking for gethostbyname... yes checking for connect... yes checking for remove... yes checking for shmat... yes checking for IceConnectionNumber in -lICE... yes checking if X11 header files can be found... yes checking for _XdmcpAuthDoIt in -lXdmcp... no checking for IceOpenConnection in -lICE... yes checking for XpmCreatePixmapFromData in -lXpm... yes checking if X11 header files implicitly declare return values... no checking --enable-gui argument... yes/auto - automatic GUI support checking whether or not to look for GTK... yes checking whether or not to look for GTK+ 2... yes checking whether or not to look for GNOME... no checking whether or not to look for Motif... yes checking whether or not to look for Athena... yes checking whether or not to look for neXtaw... yes checking whether or not to look for Carbon... yes checking --with-gtk-prefix argument... no checking --with-gtk-exec-prefix argument... no checking --disable-gtktest argument... gtk test enabled checking for gtk-config... /opt/local/bin/gtk-config checking for pkg-config... /usr/bin/pkg-config checking for GTK - version = 2.2.0... yes; found version 2.4.9 checking X11/SM/SMlib.h usability... yes checking X11/SM/SMlib.h presence... yes checking for X11/SM/SMlib.h... yes checking X11/xpm.h usability... yes checking X11/xpm.h presence... yes checking for X11/xpm.h... yes checking X11/Sunkeysym.h usability... yes checking X11/Sunkeysym.h presence... yes checking for X11/Sunkeysym.h... yes checking for XIMText in X11/Xlib.h... yes X GUI selected; xim has been enabled checking whether toupper is broken... no checking whether __DATE__ and __TIME__ work... yes checking elf.h usability... yes checking elf.h presence... yes checking for elf.h... yes checking for main in -lelf... yes checking for dirent.h that defines DIR... yes checking for library containing opendir... none required checking for sys/wait.h that defines union wait... no checking stdarg.h usability... yes checking stdarg.h presence... yes checking for stdarg.h... yes checking stdlib.h usability... yes checking stdlib.h presence... yes checking for stdlib.h... yes checking string.h usability... yes checking string.h presence... yes checking for string.h... yes checking sys/select.h usability... yes checking sys/select.h presence... yes checking for sys/select.h... yes checking sys/utsname.h usability... yes checking sys/utsname.h presence... yes checking for sys/utsname.h... yes checking termcap.h usability... yes checking termcap.h presence... yes checking for termcap.h... yes checking fcntl.h usability... yes checking fcntl.h presence... yes checking for fcntl.h... yes checking sgtty.h usability... yes checking sgtty.h presence... yes checking for sgtty.h... yes checking sys/ioctl.h usability... yes checking sys/ioctl.h presence... yes checking for sys/ioctl.h... yes checking sys/time.h usability... yes checking sys/time.h presence... yes checking for sys/time.h... yes checking sys/types.h usability... yes checking sys/types.h presence... yes checking for sys/types.h... yes checking termio.h usability... yes checking termio.h presence... yes checking for termio.h... yes checking iconv.h usability... yes checking iconv.h presence... yes checking for iconv.h... yes checking langinfo.h usability... yes checking langinfo.h presence... yes checking for langinfo.h... yes checking math.h usability... yes checking math.h presence... yes checking for math.h... yes checking unistd.h usability... yes checking unistd.h presence... yes checking for unistd.h... yes checking stropts.h usability... no checking stropts.h presence... yes configure: WARNING: stropts.h: present but cannot be compiled configure: WARNING: stropts.h: check for missing prerequisite headers? configure: WARNING: stropts.h: see the Autoconf documentation configure: WARNING: stropts.h: section "Present But Cannot Be Compiled" configure: WARNING: stropts.h: proceeding with the preprocessor's result configure: WARNING: stropts.h: in the future, the compiler will take precedence checking for stropts.h... yes checking errno.h usability... yes checking errno.h presence... yes checking for errno.h... yes checking sys/resource.h usability... yes checking sys/resource.h presence... yes checking for sys/resource.h... yes checking sys/systeminfo.h usability... yes checking sys/systeminfo.h presence... yes checking for sys/systeminfo.h... yes checking locale.h usability... yes checking locale.h presence... yes checking for locale.h... yes checking sys/stream.h usability... no checking sys/stream.h presence... yes configure: WARNING: sys/stream.h: present but cannot be compiled configure: WARNING: sys/stream.h: check for missing prerequisite headers? configure: WARNING: sys/stream.h: see the Autoconf documentation configure: WARNING: sys/stream.h: section "Present But Cannot Be Compiled" configure: WARNING: sys/stream.h: proceeding with the preprocessor's result configure: WARNING: sys/stream.h: in the future, the compiler will take precedence checking for sys/stream.h... yes checking termios.h usability... yes checking termios.h presence... yes checking for termios.h... yes checking libc.h usability... no checking libc.h presence... no checking for libc.h... no checking sys/statfs.h usability... yes checking sys/statfs.h presence... yes checking for sys/statfs.h... yes checking poll.h usability... yes checking poll.h presence... yes checking for poll.h... yes checking sys/poll.h usability... yes checking sys/poll.h presence... yes checking for sys/poll.h... yes checking pwd.h usability... yes checking pwd.h presence... yes checking for pwd.h... yes checking utime.h usability... yes checking utime.h presence... yes checking for utime.h... yes checking sys/param.h usability... yes checking sys/param.h presence... yes checking for sys/param.h... yes checking libintl.h usability... yes checking libintl.h presence... yes checking for libintl.h... yes checking libgen.h usability... yes checking libgen.h presence... yes checking for libgen.h... yes checking util/debug.h usability... no checking util/debug.h presence... no checking for util/debug.h... no checking util/msg18n.h usability... no checking util/msg18n.h presence... no checking for util/msg18n.h... no checking frame.h usability... no checking frame.h presence... no checking for frame.h... no checking sys/acl.h usability... yes checking sys/acl.h presence... yes checking for sys/acl.h... yes checking sys/access.h usability... no checking sys/access.h presence... no checking for sys/access.h... no checking sys/sysctl.h usability... no checking sys/sysctl.h presence... no checking for sys/sysctl.h... no checking sys/sysinfo.h usability... yes checking sys/sysinfo.h presence... yes checking for sys/sysinfo.h... yes checking wchar.h usability... yes checking wchar.h presence... yes checking for wchar.h... yes checking wctype.h usability... yes checking wctype.h presence... yes checking for wctype.h... yes checking for sys/ptem.h... no checking for pthread_np.h... no checking strings.h usability... yes checking strings.h presence... yes checking for strings.h... yes checking if strings.h can be included after string.h... yes checking whether gcc needs -traditional... no checking for an ANSI C-conforming const... yes checking for mode_t... yes checking for off_t... yes checking for pid_t... yes checking for size_t... yes checking for uid_t in sys/types.h... yes checking whether time.h and sys/time.h may both be included... yes checking for ino_t... yes checking for dev_t... yes checking for rlim_t... yes checking for stack_t... yes checking whether stack_t has an ss_base field... no checking --with-tlib argument... empty: automatic terminal library selection checking for tgetent in -lncurses... yes checking whether we talk terminfo... yes checking what tgetent() returns for an unknown terminal... zero checking whether termcap.h contains ospeed... yes checking whether termcap.h contains UP, BC and PC... yes checking whether tputs() uses outfuntype... no checking whether sys/select.h and sys/time.h may both be included... yes checking for /dev/ptc... no checking for SVR4 ptys... yes checking for ptyranges... don't know checking default tty permissions/group... can't determine - assume ptys are world accessable world checking return type of signal handlers... void checking for struct sigcontext... no checking getcwd implementation is broken... no checking for bcmp... yes checking for fchdir... yes checking for fchown... yes checking for fseeko... yes checking for fsync... yes checking for ftello... yes checking for getcwd... yes checking for getpseudotty... no checking for getpwnam... yes checking for getpwuid... yes checking for getrlimit... yes checking for gettimeofday... yes checking for getwd... yes checking for lstat... yes checking for memcmp... yes checking for memset... yes checking for nanosleep... no checking for opendir... yes checking for putenv... yes checking for qsort... yes checking for readlink... yes checking for select... yes checking for setenv... yes checking for setpgid... yes checking for setsid... yes checking for sigaltstack... yes checking for sigstack... yes checking for sigset... yes checking for sigsetjmp... yes checking for sigaction... yes checking for sigvec... no checking for strcasecmp... yes checking for strerror... yes checking for strftime... yes checking for stricmp... no checking for strncasecmp... yes checking for strnicmp... no checking for strpbrk... yes checking for strtol... yes checking for tgetent... yes checking for towlower... yes checking for towupper... yes checking for iswupper... yes checking for usleep... yes checking for utime... yes checking for utimes... yes checking for st_blksize... no checking whether stat() ignores a trailing slash... no checking for iconv_open()... yes; with -liconv checking for nl_langinfo(CODESET)... yes checking for strtod in -lm... yes checking for strtod() and other floating point functions... yes checking --disable-acl argument... no checking for acl_get_file in -lposix1e... no checking for acl_get_file in -lacl... no checking for POSIX ACL support... no checking for Solaris ACL support... yes checking for AIX ACL support... no checking --disable-gpm argument... no checking for gpm... no checking --disable-sysmouse argument... no checking for sysmouse... no checking for rename... yes checking for sysctl... not usable checking for sysinfo... not usable checking for sysinfo.mem_unit... no checking for sysconf... yes checking size of int... (cached) 8 checking whether memmove handles overlaps... yes checking for _xpg4_setrunelocale in -lxpg4... no checking how to create tags... ctags -t checking how to run man with a section nr... man -s checking --disable-nls argument... no checking for msgfmt... msgfmt checking for NLS... no "po/Makefile" - disabled checking dlfcn.h usability... yes checking dlfcn.h presence... yes checking for dlfcn.h... yes checking for dlopen()... yes checking for dlsym()... yes checking setjmp.h usability... yes checking setjmp.h presence... yes checking for setjmp.h... yes checking for GCC 3 or later... yes configure: updating cache auto/config.cache configure: creating auto/config.status config.status: creating auto/config.mk config.status: creating auto/config.h Make: make Starting make in the src directory. If there are problems, cd to the src directory and run make there cd src && make first mkdir objects CC="gcc -Iproto -DHAVE_CONFIG_H -DFEAT_GUI_GTK -I/usr/include/gtk-2.0 -I/usr/lib/gtk-2.0/include -I/usr/include/atk-1.0 -I/usr/include/pango-1.0 -I/usr/openwin/include -I/usr/sfw/include -I/usr/sfw/include/freetype2 -I/usr/include/glib-2.0 -I/usr/lib/glib-2.0/include -I/usr/openwin/include -I/opt/sfw/lib/ruby/1.6/sparc-solaris2.10 " srcdir=. sh ./osdef.sh gcc -c -I. -Iproto -DHAVE_CONFIG_H -DFEAT_GUI_GTK -I/usr/include/gtk-2.0 -I/usr/lib/gtk-2.0/include -I/usr/include/atk-1.0 -I/usr/include/pango-1.0 -I/usr/openwin/include -I/usr/sfw/include -I/usr/sfw/include/freetype2 -I/usr/include/glib-2.0 -I/usr/lib/glib-2.0/include -g -O2 -I/usr/openwin/include -I/opt/sfw/lib/ruby/1.6/sparc-solaris2.10 -o objects/buffer.o buffer.c In file included from os_unix.h:29, from vim.h:245, from buffer.c:28: /usr/include/sys/stat.h:251: error: syntax error before "blksize_t" /usr/include/sys/stat.h:255: error: syntax error before '}' token /usr/include/sys/stat.h:309: error: syntax error before "blksize_t" /usr/include/sys/stat.h:310: error: conflicting types for 'st_blocks' /usr/include/sys/stat.h:252: error: previous declaration of 'st_blocks' was here /usr/include/sys/stat.h:313: error: syntax error before '}' token In file included from /opt/local/bin/../lib/gcc/sparc-sun-solaris2.6/3.4.6/include/sys/signal.h:132, from /usr/include/signal.h:26, from os_unix.h:163, from vim.h:245, from buffer.c:28: /usr/include/sys/siginfo.h:259: error: syntax error before "ctid_t" /usr/include/sys/siginfo.h:292: error: syntax error before '}' token /usr/include/sys/siginfo.h:294: error: syntax error before '}' token /usr/include/sys/siginfo.h:390: error: syntax error before "ctid_t" /usr/include/sys/siginfo.h:398: error: conflicting types for '__fault' /usr/include/sys/siginfo.h:267: error: previous declaration of '__fault' was here /usr/include/sys/siginfo.h:404: error: conflicting types for '__file' /usr/include/sys/siginfo.h:273: error: previous declaration of '__file' was here /usr/include/sys/siginfo.h:420: error: conflicting types for '__prof' /usr/include/sys/siginfo.h:287: error: previous declaration of '__prof' was here /usr/include/sys/siginfo.h:424: error: conflicting types for '__rctl' /usr/include/sys/siginfo.h:291: error: previous declaration of '__rctl' was here /usr/include/sys/siginfo.h:426: error: syntax error before '}' token /usr/include/sys/siginfo.h:428: error: syntax error before '}' token /usr/include/sys/siginfo.h:432: error: syntax error before "k_siginfo_t" /usr/include/sys/siginfo.h:437: error: syntax error before '}' token In file included from /usr/include/signal.h:26, from os_unix.h:163, from vim.h:245, from buffer.c:28: /opt/local/bin/../lib/gcc/sparc-sun-solaris2.6/3.4.6/include/sys/signal.h:173: error: syntax error before "siginfo_t" In file included from os_unix.h:163, from vim.h:245, from buffer.c:28: /usr/include/signal.h:111: error: syntax error before "siginfo_t" /usr/include/signal.h:113: error: syntax error before "siginfo_t" buffer.c: In function `buflist_new': buffer.c:1502: error: storage size of 'st' isn't known buffer.c: In function `buflist_findname': buffer.c:1989: error: storage size of 'st' isn't known buffer.c: In function `setfname': buffer.c:2578: error: storage size of 'st' isn't known buffer.c: In function `otherfile_buf': buffer.c:2836: error: storage size of 'st' isn't known buffer.c: In function `buf_setino': buffer.c:2874: error: storage size of 'st' isn't known buffer.c: In function `buf_same_ino': buffer.c:2894: error: dereferencing pointer to incomplete type buffer.c:2895: error: dereferencing pointer to incomplete type *** Error code 1 make: Fatal error: Command failed for target `objects/buffer.o' Current working directory /home/xluntor/vim72/src *** Error code 1 make: Fatal error: Command failed for target `first'

    Read the article

  • The Benefits of Smart Grid Business Software

    - by Sylvie MacKenzie, PMP
    Smart Grid Background What Are Smart Grids?Smart Grids use computer hardware and software, sensors, controls, and telecommunications equipment and services to: Link customers to information that helps them manage consumption and use electricity wisely. Enable customers to respond to utility notices in ways that help minimize the duration of overloads, bottlenecks, and outages. Provide utilities with information that helps them improve performance and control costs. What Is Driving Smart Grid Development? Environmental ImpactSmart Grid development is picking up speed because of the widespread interest in reducing the negative impact that energy use has on the environment. Smart Grids use technology to drive efficiencies in transmission, distribution, and consumption. As a result, utilities can serve customers’ power needs with fewer generating plants, fewer transmission and distribution assets,and lower overall generation. With the possible exception of wind farm sprawl, landscape preservation is one obvious benefit. And because most generation today results in greenhouse gas emissions, Smart Grids reduce air pollution and the potential for global climate change.Smart Grids also more easily accommodate the technical difficulties of integrating intermittent renewable resources like wind and solar into the grid, providing further greenhouse gas reductions. CostsThe ability to defer the cost of plant and grid expansion is a major benefit to both utilities and customers. Utilities do not need to use as many internal resources for traditional infrastructure project planning and management. Large T&D infrastructure expansion costs are not passed on to customers.Smart Grids will not eliminate capital expansion, of course. Transmission corridors to connect renewable generation with customers will require major near-term expenditures. Additionally, in the future, electricity to satisfy the needs of population growth and additional applications will exceed the capacity reductions available through the Smart Grid. At that point, expansion will resume—but with greater overall T&D efficiency based on demand response, load control, and many other Smart Grid technologies and business processes. Energy efficiency is a second area of Smart Grid cost saving of particular relevance to customers. The timely and detailed information Smart Grids provide encourages customers to limit waste, adopt energy-efficient building codes and standards, and invest in energy efficient appliances. Efficiency may or may not lower customer bills because customer efficiency savings may be offset by higher costs in generation fuels or carbon taxes. It is clear, however, that bills will be lower with efficiency than without it. Utility Operations Smart Grids can serve as the central focus of utility initiatives to improve business processes. Many utilities have long “wish lists” of projects and applications they would like to fund in order to improve customer service or ease staff’s burden of repetitious work, but they have difficulty cost-justifying the changes, especially in the short term. Adding Smart Grid benefits to the cost/benefit analysis frequently tips the scales in favor of the change and can also significantly reduce payback periods.Mobile workforce applications and asset management applications work together to deploy assets and then to maintain, repair, and replace them. Many additional benefits result—for instance, increased productivity and fuel savings from better routing. Similarly, customer portals that provide customers with near-real-time information can also encourage online payments, thus lowering billing costs. Utilities can and should include these cost and service improvements in the list of Smart Grid benefits. What Is Smart Grid Business Software? Smart Grid business software gathers data from a Smart Grid and uses it improve a utility’s business processes. Smart Grid business software also helps utilities provide relevant information to customers who can then use it to reduce their own consumption and improve their environmental profiles. Smart Grid Business Software Minimizes the Impact of Peak Demand Utilities must size their assets to accommodate their highest peak demand. The higher the peak rises above base demand: The more assets a utility must build that are used only for brief periods—an inefficient use of capital. The higher the utility’s risk profile rises given the uncertainties surrounding the time needed for permitting, building, and recouping costs. The higher the costs for utilities to purchase supply, because generators can charge more for contracts and spot supply during high-demand periods. Smart Grids enable a variety of programs that reduce peak demand, including: Time-of-use pricing and critical peak pricing—programs that charge customers more when they consume electricity during peak periods. Pilot projects indicate that these programs are successful in flattening peaks, thus ensuring better use of existing T&D and generation assets. Direct load control, which lets utilities reduce or eliminate electricity flow to customer equipment (such as air conditioners). Contracts govern the terms and conditions of these turn-offs. Indirect load control, which signals customers to reduce the use of on-premises equipment for contractually agreed-on time periods. Smart Grid business software enables utilities to impose penalties on customers who do not comply with their contracts. Smart Grids also help utilities manage peaks with existing assets by enabling: Real-time asset monitoring and control. In this application, advanced sensors safely enable dynamic capacity load limits, ensuring that all grid assets can be used to their maximum capacity during peak demand periods. Real-time asset monitoring and control applications also detect the location of excessive losses and pinpoint need for mitigation and asset replacements. As a result, utilities reduce outage risk and guard against excess capacity or “over-build”. Better peak demand analysis. As a result: Distribution planners can better size equipment (e.g. transformers) to avoid over-building. Operations engineers can identify and resolve bottlenecks and other inefficiencies that may cause or exacerbate peaks. As above, the result is a reduction in the tendency to over-build. Supply managers can more closely match procurement with delivery. As a result, they can fine-tune supply portfolios, reducing the tendency to over-contract for peak supply and reducing the need to resort to spot market purchases during high peaks. Smart Grids can help lower the cost of remaining peaks by: Standardizing interconnections for new distributed resources (such as electricity storage devices). Placing the interconnections where needed to support anticipated grid congestion. Smart Grid Business Software Lowers the Cost of Field Services By processing Smart Grid data through their business software, utilities can reduce such field costs as: Vegetation management. Smart Grids can pinpoint momentary interruptions and tree-caused outages. Spatial mash-up tools leverage GIS models of tree growth for targeted vegetation management. This reduces the cost of unnecessary tree trimming. Service vehicle fuel. Many utility service calls are “false alarms.” Checking meter status before dispatching crews prevents many unnecessary “truck rolls.” Similarly, crews use far less fuel when Smart Grid sensors can pinpoint a problem and mobile workforce applications can then route them directly to it. Smart Grid Business Software Ensures Regulatory Compliance Smart Grids can ensure compliance with private contracts and with regional, national, or international requirements by: Monitoring fulfillment of contract terms. Utilities can use one-hour interval meters to ensure that interruptible (“non-core”) customers actually reduce or eliminate deliveries as required. They can use the information to levy fines against contract violators. Monitoring regulations imposed on customers, such as maximum use during specific time periods. Using accurate time-stamped event history derived from intelligent devices distributed throughout the smart grid to monitor and report reliability statistics and risk compliance. Automating business processes and activities that ensure compliance with security and reliability measures (e.g. NERC-CIP 2-9). Grid Business Software Strengthens Utilities’ Connection to Customers While Reducing Customer Service Costs During outages, Smart Grid business software can: Identify outages more quickly. Software uses sensors to pinpoint outages and nested outage locations. They also permit utilities to ensure outage resolution at every meter location. Size outages more accurately, permitting utilities to dispatch crews that have the skills needed, in appropriate numbers. Provide updates on outage location and expected duration. This information helps call centers inform customers about the timing of service restoration. Smart Grids also facilitates display of outage maps for customer and public-service use. Smart Grids can significantly reduce the cost to: Connect and disconnect customers. Meters capable of remote disconnect can virtually eliminate the costs of field crews and vehicles previously required to change service from the old to the new residents of a metered property or disconnect customers for nonpayment. Resolve reports of voltage fluctuation. Smart Grids gather and report voltage and power quality data from meters and grid sensors, enabling utilities to pinpoint reported problems or resolve them before customers complain. Detect and resolve non-technical losses (e.g. theft). Smart Grids can identify illegal attempts to reconnect meters or to use electricity in supposedly vacant premises. They can also detect theft by comparing flows through delivery assets with billed consumption. Smart Grids also facilitate outreach to customers. By monitoring and analyzing consumption over time, utilities can: Identify customers with unusually high usage and contact them before they receive a bill. They can also suggest conservation techniques that might help to limit consumption. This can head off “high bill” complaints to the contact center. Note that such “high usage” or “additional charges apply because you are out of range” notices—frequently via text messaging—are already common among mobile phone providers. Help customers identify appropriate bill payment alternatives (budget billing, prepayment, etc.). Help customers find and reduce causes of over-consumption. There’s no waiting for bills in the mail before they even understand there is a problem. Utilities benefit not just through improved customer relations but also through limiting the size of bills from customers who might struggle to pay them. Where permitted, Smart Grids can open the doors to such new utility service offerings as: Monitoring properties. Landlords reduce costs of vacant properties when utilities notify them of unexpected energy or water consumption. Utilities can perform similar services for owners of vacation properties or the adult children of aging parents. Monitoring equipment. Power-use patterns can reveal a need for equipment maintenance. Smart Grids permit utilities to alert owners or managers to a need for maintenance or replacement. Facilitating home and small-business networks. Smart Grids can provide a gateway to equipment networks that automate control or let owners access equipment remotely. They also facilitate net metering, offering some utilities a path toward involvement in small-scale solar or wind generation. Prepayment plans that do not need special meters. Smart Grid Business Software Helps Customers Control Energy Costs There is no end to the ways Smart Grids help both small and large customers control energy costs. For instance: Multi-premises customers appreciate having all meters read on the same day so that they can more easily compare consumption at various sites. Customers in competitive regions can match their consumption profile (detailed via Smart Grid data) with specific offerings from competitive suppliers. Customers seeing inexplicable consumption patterns and power quality problems may investigate further. The result can be discovery of electrical problems that can be resolved through rewiring or maintenance—before more serious fires or accidents happen. Smart Grid Business Software Facilitates Use of Renewables Generation from wind and solar resources is a popular alternative to fossil fuel generation, which emits greenhouse gases. Wind and solar generation may also increase energy security in regions that currently import fossil fuel for use in generation. Utilities face many technical issues as they attempt to integrate intermittent resource generation into traditional grids, which traditionally handle only fully dispatchable generation. Smart Grid business software helps solves many of these issues by: Detecting sudden drops in production from renewables-generated electricity (wind and solar) and automatically triggering electricity storage and smart appliance response to compensate as needed. Supporting industry-standard distributed generation interconnection processes to reduce interconnection costs and avoid adding renewable supplies to locations already subject to grid congestion. Facilitating modeling and monitoring of locally generated supply from renewables and thus helping to maximize their use. Increasing the efficiency of “net metering” (through which utilities can use electricity generated by customers) by: Providing data for analysis. Integrating the production and consumption aspects of customer accounts. During non-peak periods, such techniques enable utilities to increase the percent of renewable generation in their supply mix. During peak periods, Smart Grid business software controls circuit reconfiguration to maximize available capacity. Conclusion Utility missions are changing. Yesterday, they focused on delivery of reasonably priced energy and water. Tomorrow, their missions will expand to encompass sustainable use and environmental improvement.Smart Grids are key to helping utilities achieve this expanded mission. But they come at a relatively high price. Utilities will need to invest heavily in new hardware, software, business process development, and staff training. Customer investments in home area networks and smart appliances will be large. Learning to change the energy and water consumption habits of a lifetime could ultimately prove even more formidable tasks.Smart Grid business software can ease the cost and difficulties inherent in a needed transition to a more flexible, reliable, responsive electricity grid. Justifying its implementation, however, requires a full understanding of the benefits it brings—benefits that can ultimately help customers, utilities, communities, and the world address global issues like energy security and climate change while minimizing costs and maximizing customer convenience. This white paper is available for download here. For further information about Oracle's Primavera Solutions for Utilities, please read our Utilities e-book.

    Read the article

  • Project Management Helps AmeriCares Deliver International Aid

    - by Sylvie MacKenzie, PMP
    Excerpt from PROFIT - ORACLE - by Alison Weiss Handle with Care Sound project management helps AmeriCares bring international aid to those in need. The stakes are always high for AmeriCares. On a mission to restore health and save lives during times of disaster, the nonprofit international relief and humanitarian aid organization delivers donated medicines, medical supplies, and humanitarian aid to people in the U.S. and around the globe. Founded in 1982 with the express mission of responding as quickly and efficiently as possible to help people in need, the Stamford, Connecticut-based AmeriCares has delivered more than US$10.5 billion in aid to 147 countries over the past three decades. Launch the Slideshow “It’s critically important to us that we steward all the donations and that the medical supplies and medicines get to people as quickly as possible with no loss,” says Kate Sears, senior vice president for finance and technology at AmeriCares. “Whether we’re shipping IV solutions to victims of cholera in Haiti or antibiotics to Somali famine victims, we need to get the medicines there sooner because it means more people will be helped and lives improved or even saved.” Ten years ago, the tracking systems used by AmeriCares associates were paper-based. In recent years, staff started using spreadsheets, but the tracking processes were not standardized between teams. “Every team was tracking completely different information,” says Megan McDermott, senior associate, Sub-Saharan Africa partnerships, at AmeriCares. “It was just a few key things. For example, we tracked the date a shipment was supposed to arrive and the date we got reports from our partner that a hospital received aid on their end.” While the data was accurate, much detail was being lost in the process. AmeriCares management knew it could do a better job of tracking this enterprise data and in 2011 took a significant step by implementing Oracle’s Primavera P6 Professional Project Management. “It’s a comprehensive solution that has helped us improve the monitoring and controlling processes. It has allowed us to do our distribution better,” says Sears. In addition, the implementation effort has been a change agent, helping AmeriCares leadership rethink project management across the entire organization. Initially, much of the focus was on standardizing processes, but staff members also learned the importance of thinking proactively to prevent possible problems and evaluating results to determine if goals and objectives are truly being met. Such data about process efficiency and overall results is critical not only to AmeriCares staff but also to the donors supporting the organization’s life-saving missions. Efficiency Saves Lives One of AmeriCares’ core operations is to gather product donations from the private sector, establish where the most-urgent needs are, and solicit monetary support to send the aid via ocean cargo or airlift to welfare- and health-oriented nongovernmental organizations, hospitals, health networks, and government ministries based in areas in need. In 2011 alone, AmeriCares sent more than 3,500 shipments to 95 countries in response to both ongoing humanitarian needs and more than two dozen emergencies, including deadly tornadoes and storms in the U.S. and the devastating tsunami in Japan. When it comes to nonprofits in general, donors want to know that the charitable organizations they support are using funds wisely. Typically, nonprofits are evaluated by donors in terms of efficiency, an area where AmeriCares has an excellent reputation: 98 percent of expenses go directly to supporting programs and less than 2 percent represent administrative and fundraising costs. Donors, however, should look at more than simple efficiency, says Peter York, senior partner and chief research and learning officer at TCC Group, a nonprofit consultancy headquartered in New York, New York. They should also look at whether organizations have the systems in place to sustain their missions and continue to thrive. An expert on nonprofit organizational management, York has spent years studying sustainable charitable organizations. He defines them as nonprofits that are able to achieve the ongoing financial support to stay relevant and continue doing core mission work. In his analysis of well over 2,500 larger nonprofits, York has found that many are not sustaining, and are actually scaling back in size. “One of the biggest challenges of nonprofit sustainability is the general public’s perception that every dollar donated has to go only to the delivery of service,” says York. “What our data shows is that there are some fundamental capacities that have to be there in order for organizations to sustain and grow.” York’s research highlights the importance of data-driven leadership at successful nonprofits. “You’ve got to have the tools, the systems, and the technologies to get objective information on what you do, the people you serve, and the results you’re achieving,” says York. “If leaders don’t have the knowledge and the data, they can’t make the strategic decisions about programs to take organizations to the next level.” Historically, AmeriCares associates have used time-tested and cost-effective strategies to ship and then track supplies from donation to delivery to their destinations in designated time frames. When disaster strikes, AmeriCares ships by air and generally pulls out all the stops to deliver the most urgently needed aid within the first few days and weeks. Then, as situations stabilize, AmeriCares turns to delivering sea containers for the postemergency and ongoing aid so often needed over the long term. According to McDermott, getting a shipment out the door is fairly complicated, requiring as many as five different AmeriCares teams collaborating together. The entire process can take months—from when products are received in the warehouse and deciding which recipients to allocate supplies to, to getting customs and governmental approvals in place, actually shipping products, and finally ensuring that the products are received in-country. Delivering that aid is no small affair. “Our volume exceeds half a billion dollars a year worth of donated medicines and medical supplies, so it’s a sizable logistical operation to bring these products in and get them out to the right place quickly to have the most impact,” says Sears. “We really pride ourselves on our controls and efficiencies.” Adding to that complexity is the fact that the longer it takes to deliver aid, the more dire the human need can be. Any time AmeriCares associates can shave off the complicated aid delivery process can translate into lives saved. “It’s really being able to track information consistently that will help us to see where are the bottlenecks and where can we work on improving our processes,” says McDermott. Setting a Standard Productivity and information management improvements were key objectives for AmeriCares when staff began the process of implementing Oracle’s Primavera solution. But before configuring the software, the staff needed to take the time to analyze the systems already in place. According to Greg Loop, manager of database systems at AmeriCares, the organization received guidance from several consultants, including Rich D’Addario, consulting project manager in the Primavera Global Business Unit at Oracle, who was instrumental in shepherding the critical requirements-gathering phase. D’Addario encouraged staff to begin documenting shipping processes by considering the order in which activities occur and which ones are dependent on others to get accomplished. This exercise helped everyone realize that to be more efficient, they needed to keep track of shipments in a more standard way. “The staff didn’t recognize formal project management methodology,” says D’Addario. “But they did understand what the most important things are and that if they go wrong, an entire project can go off course.” Before, if a boatload of supplies was being sent to Haiti and there was a problem somewhere, a lot of time was taken up finding out where the problem was—because staff was not tracking things in a standard way. As a result, even more time was needed to find possible solutions to the problem and alert recipients that the aid might be delayed. “For everyone to put on the project manager hat and standardize the way every single thing is done means that now the whole organization is on the same page as to what needs to occur from the time a hurricane hits Haiti and when a boat pulls in to unload supplies,” says D’Addario. With so much care taken to put a process foundation firmly in place, configuring the Primavera solution was actually quite simple. Specific templates were set up for different types of shipments, and dashboards were implemented to provide executives with clear overviews of every project in the system. AmeriCares’ Loop reports that system planning, refining, and testing, followed by writing up documentation and training, took approximately four months. The system went live in spring 2011 at AmeriCares’ Connecticut headquarters. While the nonprofit has an international presence, with warehouses in Europe and offices in Haiti, India, Japan, and Sri Lanka, most donated medicines come from U.S. entities and are shipped from the U.S. out to the rest of the world. In addition, all shipments are tracked from the U.S. office. AmeriCares doesn’t expect the Primavera system to take months off the shipping time, especially for sea containers. However, any time saved is still important because it will allow aid to be delivered to people more quickly at a lower overall cost. “If we can trim a day or two here or there, that can translate into lives that we’re saving, especially in emergency situations,” says Sears. A Cultural Change Beyond the measurable benefits that come with IT-driven process improvement, AmeriCares management is seeing a change in culture as a result of the Primavera project. One change has been treating every shipment of aid as a project, and everyone involved with facilitating shipments as a project manager. “This is a revolutionary concept for us,” says McDermott. “Before, we were used to thinking we were doing logistics—getting a container from point A to point B without looking at it as one project and really understanding what it meant to manage it.” AmeriCares staff is also happy to report that collaboration within the organization is much more efficient. When someone creates a shipment in the Primavera system, the same shared template is used, which means anyone can log in to the system to see the status of a shipment. Knowledgeable staff can access a shipment project to help troubleshoot a problem. Management can easily check the status of projects across the organization. “Dashboards are really useful,” says McDermott. “Instead of going into the details of each project, you can just see the high-level real-time information at a glance.” The new system is helping team members focus on proactively managing shipments rather than simply reacting when problems occur. For example, when a container is shipped, documents must be included for customs clearance. Now, the shipping template has built-in reminders to prompt team members to ask for copies of these documents from freight forwarders and to follow up with partners to discover if a shipment is on time. In the past, staff may not have worked on securing these documents until they’d been notified a shipment had arrived in-country. Another benefit of capturing and adopting best practices within the Primavera system is that staff training is easier. “Capturing the processes in documented steps and milestones allows us to teach new staff members how to do their jobs faster,” says Sears. “It provides them with the knowledge of their predecessors so they don’t have to keep reinventing the wheel.” With the Primavera system already generating positive results, management is eager to take advantage of advanced capabilities. Loop is working on integrating the company’s proprietary inventory management system with the Primavera system so that when logistics or warehousing operators input data, the information will automatically go into the Primavera system. In the past, this information had to be manually keyed into spreadsheets, often leading to errors. Mining Historical Data Another feature on the horizon for AmeriCares is utilizing Primavera P6 Professional Project Management reporting capabilities. As the system begins to include more historical data, management soon will be able to draw on this information to conduct analysis that has not been possible before and create customized reports. For example, at the beginning of the shipment process, staff will be able to use historical data to more accurately estimate how long the approval process should take for a particular country. This could help ensure that food and medicine with limited shelf lives do not get stuck in customs or used beyond their expiration dates. The historical data in the Primavera system will also help AmeriCares with better planning year to year. The nonprofit’s staff has always put together a plan at the beginning of the year, but this has been very challenging simply because it is impossible to predict disasters. Now, management will be able to look at historical data and see trends and statistics as they set current objectives and prepare for future need. In addition, this historical data will provide AmeriCares management with the ability to review year-end data and compare actual project results with goals set at the beginning of the year—to see if desired outcomes were achieved and if there are areas that need improvement. It’s this type of information that is so valuable to donors. And, according to York, project management software can play a critical role in generating the data to help nonprofits sustain and grow. “It is important to invest in systems to help replicate, expand, and deliver services,” says York. “Project management software can help because it encourages nonprofits to examine program or service changes and how to manage moving forward.” Sears believes that AmeriCares donors will support the return on investment the organization will achieve with the Primavera solution. “It won’t be financial returns, but rather how many more people we can help for a given dollar or how much more quickly we can respond to a need,” says Sears. “I think donors are receptive to such arguments.” And for AmeriCares, it is all about the future and increasing results. The project management environment currently may be quite simple, but IT staff plans to expand the complexity and functionality as the organization grows in its knowledge of project management and the goals it wants to achieve. “As we use the system over time, we’ll continue to refine our best practices and accumulate more data,” says Sears. “It will advance our ability to make better data-driven decisions.”

    Read the article

  • Can't install Git

    - by davemc
    Im following the tutorial below to install git. https://help.github.com/articles/set-up-git However when I get to the end where I need to install the helper into the same directory where Git itself is installed i get the following error: Davids-iMac:~ davidcavanagh$ which git /usr/bin/git Davids-iMac:~ davidcavanagh$ sudo mv git-credential-osxkeychain /usr/bin mv: rename git-credential-osxkeychain to /usr/bin/git-credential-osxkeychain: No such file or directory Davids-iMac:~ davidcavanagh$ Edit: I am now getting the following error when I install git and then run git -version Davids-iMac:~ davidcavanagh$ git -version /usr/bin/git: line 1: syntax error near unexpected token `newline' /usr/bin/git: line 1: `<?xml version="1.0" encoding="UTF-8"?>' I was following this tutorial guide:https://help.github.com/articles/set-up-git I have also tried using home-brew as well and I get the following error when I do this: Davids-iMac:~ davidcavanagh$ ruby -e "$(curl -fsSkL raw.github.com/mxcl/homebrew/go)" ==> This script will install: /usr/local/bin/brew /usr/local/Library/... /usr/local/share/man/man1/brew.1 Press ENTER to continue or any other key to abort ==> Downloading and Installing Homebrew... Failed during: git init -q Can anyone help? Thanks

    Read the article

  • QNTC and Windows Server 2008 R2

    - by Ben
    I am having a really hard time getting an iSeries (AS/400) machine talking to my new Windows Server 2008 R2 box using the QNTC file system on the iSeries. I had similar problems getting it to initially talk to a Windows Server 2003 machine, but enabling the local Guest account on the 2003 box solved that one. No such luck with the new 2008 box. When I do a WRKLNK /QNTC/SVR01 on the iSeries (which should show share listings, and does on any 2003 boxes) all I get is (Cannot find object to match specified name.). I know the iSeries likes the same username and password on the remote server, but unfortunately for us this is not the case. Anyhow, it does currently work with different username/password combinations on a 2003 box. To try and get the wretched things talking, I have made the 2008 server pretty open but the iSeries will not see shares on it. I have enabled the local Guest account, turned Windows firewall off, set the share permissions so Everyone has full control but to no avail. I read something on the internet about the iSeries only being able to handle NTLM authentication (and I understand by default that Server 2008 R2 only uses NTLMv2 and has NTLM disabled), so I made a special group policy for the server and tweaked all Group Policy settings under Computer Configuration\Policies\Windows Settings\Security Settings\Local Policies\Security Options but the iSeries STILL won't see it. We have a team of programmers who do all the system administration of the iSeries, but they are stumped for ideas on their side, and I'm stumped for ideas on my side. This is driving me crazy now, and if anybody has managed to get an iSeries to talk to Windows Server 2008 R2 using QNTC I would be very appreciative of any suggestions, be it on the Windows side, iSeries settings or even IBM PTF's that might patch anything. The iSeries is running V5R4 and I have *SECOFR privileges on it, if it helps. One final (most important!) note - The programmers think it's my system being tricky, and I think it's theirs - please prove me right :)

    Read the article

  • "Error in the Site Data Web Service." when performing crawl

    - by Janis Veinbergs
    Installed SharePoint Services v3 (SP2, october 2009 cumulative updates, Language Pack), attached to a content database I had previously (all works). Installed Search server 2008 Express (with language pack) on top of WSS and crawl does not work. However it works for newly created web application + database. Was playing around with accounts, permissions to try get it working. Currently I have WSS_Crawler account with such permissions: Office Search Server runs with WSS_Crawler account Config database has read permissions for WSS_Crawler Content database has read permissions for WSS_Crawler WSS_Crawler is owner of search database. Added WSS_Crawler to SQL server browser user group and administrator Yes, i'v given more permissions than needed, but it doesn't even work with that and i don't know if its permission problem or what. Crawl log says there is Error in the Site Data Web Service., nothing more. There were known issues with a similar error: Error in the Site Data Web Service. (Value does not fall within the expected range.), but this is not the case as thats an old issue and i hope it has been included in SP2... Logs are from olders to newest (descending order). They don't appear to be very helpful. Crawl log http://serveris Crawled Local Office SharePoint Server sites 3/15/2010 9:39 AM sts3://serveris Crawled Local Office SharePoint Server sites 3/15/2010 9:39 AM sts3://serveris/contentdbid={55180cfa-9d2d-46e4... Crawled Local Office SharePoint Server sites 3/15/2010 9:39 AM http://serveris/test Error in the Site Data Web Service. Local Office SharePoint Server sites 3/15/2010 9:39 AM http://serveris Error in the Site Data Web Service. Local Office SharePoint Server sites 3/15/2010 9:39 AM EventLog No errors in EventLog, just some Information events that Office Server Search provides The search service started. Successfully stored the application configuration registry snapshot in the database. Context: Application 'SharedServices Component: da1288b2-4109-4219-8c0c-3a22802eb842 Catalog: Portal_Content. A master merge was started due to an external request. Component: da1288b2-4109-4219-8c0c-3a22802eb842 A master merge has completed for catalog Portal_Content. Component: da1288b2-4109-4219-8c0c-3a22802eb842 Catalog: AnchorProject. A master merge was started due to an external request. Component: da1288b2-4109-4219-8c0c-3a22802eb842 A master merge has completed for catalog AnchorProject. ULS Log Just some information, but no exceptions, unexpected errors 03/15/2010 09:03:28.28 mssearch.exe (0x1B2C) 0x0E8C Search Server Common GatherStatus 0 Monitorable Insert crawl 771 to inprogress queue hr 0x00000000 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:6591 03/15/2010 09:03:28.28 mssearch.exe (0x1B2C) 0x0E8C Search Server Common GatherStatus 0 Monitorable Request Start Crawl 1, project Portal_Content, crawl 771 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:2875 03/15/2010 09:03:28.28 mssearch.exe (0x1B2C) 0x0E8C Search Server Common GatherStatus 0 Monitorable Advise status change 1, project Portal_Content, crawl 771 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:28.28 w3wp.exe (0x1D98) 0x0958 Search Server Common MS Search Administration 8wn6 Information A full crawl was started on 'Local Office SharePoint Server sites' by BALTICOVO\janis.veinbergs. 03/15/2010 09:03:28.43 mssdmn.exe (0x1750) 0x10F8 ULS Logging Unified Logging Service 8wsv High ULS Init Completed (mssdmn.exe, Microsoft.Office.Server.Native.dll) 03/15/2010 09:03:30.48 mssdmn.exe (0x1750) 0x09C0 Search Server Common MS Search Indexing 8z0v Medium Create CCache 03/15/2010 09:03:30.56 mssdmn.exe (0x1750) 0x09C0 Search Server Common MS Search Indexing 8z0z Medium Create CUserCatalogCache 03/15/2010 09:03:32.06 w3wp.exe (0x1D98) 0x0958 Search Server Common MS Search Administration 90ge Medium SQL: dbo.proc_MSS_PropagationGetQueryServers 03/15/2010 09:03:32.09 w3wp.exe (0x1D98) 0x0958 Search Server Common MS Search Administration 7phq High GetProtocolConfigHelper failed in GetNotesInterface(). 03/15/2010 09:03:34.26 mssearch.exe (0x1B2C) 0x16A4 Search Server Common GatherStatus 0 Monitorable Advise status change 12, project Portal_Content, crawl -1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:35.92 mssearch.exe (0x1B2C) 0x16A4 Search Server Common GatherStatus 0 Monitorable Advise status change 12, project Portal_Content, crawl -1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:37.32 mssearch.exe (0x1B2C) 0x16A4 Search Server Common GatherStatus 0 Monitorable Advise status change 12, project Portal_Content, crawl -1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:37.23 mssdmn.exe (0x1750) 0x1850 Search Server Common MS Search Indexing 8z14 Medium Test TRACE (NULL):(null), (NULL)(null), (CrLf): , end 03/15/2010 09:03:39.04 mssearch.exe (0x1B2C) 0x16A4 Search Server Common GatherStatus 0 Monitorable Advise status change 12, project Portal_Content, crawl -1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:40.98 mssdmn.exe (0x1750) 0x0B24 Search Server Common MS Search Indexing 7how Monitorable GetWebDefaultPage fail. error 2147755542, strWebUrl http://serveris 03/15/2010 09:03:41.87 mssdmn.exe (0x1750) 0x1260 Search Server Common PHSts 0 Monitorable CSTS3Accessor::GetSubWebListItemAccessURL GetAccessURL failed: Return error to caller, hr=80042616 - File:d:\office\source\search\search\gather\protocols\sts3\sts3acc.cxx Line:505 03/15/2010 09:03:41.87 mssdmn.exe (0x1750) 0x1260 Search Server Common PHSts 0 Monitorable CSTS3Accessor::Init: GetSubWebListItemAccessURL failed. Return error to caller, hr=80042616 - File:d:\office\source\search\search\gather\protocols\sts3\sts3acc.cxx Line:348 03/15/2010 09:03:41.87 mssdmn.exe (0x1750) 0x1260 Search Server Common PHSts 0 Monitorable CSTS3Accessor::Init fails, Url sts3://serveris/siteurl=test/siteid={390611b2-55f3-4a99-8600-778727177a28}/weburl=/webid={fb0e4bff-65d5-4ded-98d5-fd099456962b}, hr=80042616 - File:d:\office\source\search\search\gather\protocols\sts3\sts3handler.cxx Line:243 03/15/2010 09:03:41.87 mssdmn.exe (0x1750) 0x1260 Search Server Common PHSts 0 Monitorable CSTS3Handler::CreateAccessorExB: Return error to caller, hr=80042616 - File:d:\office\source\search\search\gather\protocols\sts3\sts3handler.cxx Line:261 03/15/2010 09:03:40.98 mssdmn.exe (0x1750) 0x1260 Search Server Common MS Search Indexing 7how Monitorable GetWebDefaultPage fail. error 2147755542, strWebUrl http://serveris/test 03/15/2010 09:03:41.90 mssdmn.exe (0x1750) 0x0B24 Search Server Common PHSts 0 Monitorable CSTS3Accessor::GetSubWebListItemAccessURL GetAccessURL failed: Return error to caller, hr=80042616 - File:d:\office\source\search\search\gather\protocols\sts3\sts3acc.cxx Line:505 03/15/2010 09:03:41.90 mssdmn.exe (0x1750) 0x0B24 Search Server Common PHSts 0 Monitorable CSTS3Accessor::Init: GetSubWebListItemAccessURL failed. Return error to caller, hr=80042616 - File:d:\office\source\search\search\gather\protocols\sts3\sts3acc.cxx Line:348 03/15/2010 09:03:41.90 mssdmn.exe (0x1750) 0x0B24 Search Server Common PHSts 0 Monitorable CSTS3Accessor::Init fails, Url sts3://serveris/siteurl=/siteid={505443fa-ef12-4f1e-a04b-d5450c939b78}/weburl=/webid={c5a4f8aa-9561-4527-9e1a-b3c23200f11c}, hr=80042616 - File:d:\office\source\search\search\gather\protocols\sts3\sts3handler.cxx Line:243 03/15/2010 09:03:41.90 mssdmn.exe (0x1750) 0x0B24 Search Server Common PHSts 0 Monitorable CSTS3Handler::CreateAccessorExB: Return error to caller, hr=80042616 - File:d:\office\source\search\search\gather\protocols\sts3\sts3handler.cxx Line:261 03/15/2010 09:03:43.26 mssearch.exe (0x1B2C) 0x0750 Search Server Common GatherStatus 0 Monitorable Advise status change 24, project Portal_Content, crawl 771 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:43.26 mssearch.exe (0x1B2C) 0x1804 Search Server Common GatherStatus 0 Monitorable Remove crawl 771 from inprogress queue - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:6722 03/15/2010 09:03:43.26 mssearch.exe (0x1B2C) 0x0750 Search Server Common GatherStatus 0 Monitorable Advise status change 12, project Portal_Content, crawl -1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:44.65 mssearch.exe (0x1B2C) 0x1804 Search Server Common GatherStatus 0 Monitorable Insert crawl 772 to inprogress queue hr 0x00000000 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:6591 03/15/2010 09:03:44.65 mssearch.exe (0x1B2C) 0x1804 Search Server Common GatherStatus 0 Monitorable Request Start Crawl 0, project AnchorProject, crawl 772 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:2875 03/15/2010 09:03:44.65 mssearch.exe (0x1B2C) 0x1804 Search Server Common GatherStatus 0 Monitorable Advise status change 0, project AnchorProject, crawl 772 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:44.65 mssearch.exe (0x1B2C) 0x1804 Search Server Common GatherStatus 0 Monitorable Unlock Queue, project Portal_Content - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:2922 03/15/2010 09:03:44.82 mssearch.exe (0x1B2C) 0x1DD0 Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 0 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:44.95 mssearch.exe (0x1B2C) 0x0750 Search Server Common GatherStatus 0 Monitorable Advise status change 12, project AnchorProject, crawl -1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:46.51 mssearch.exe (0x1B2C) 0x0750 Search Server Common GatherStatus 0 Monitorable Advise status change 12, project AnchorProject, crawl -1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:46.39 mssearch.exe (0x1B2C) 0x1E4C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 0 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:49.01 mssearch.exe (0x1B2C) 0x1C6C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:49.87 mssearch.exe (0x1B2C) 0x155C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:49.29 mssearch.exe (0x1B2C) 0x155C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:49.53 mssearch.exe (0x1B2C) 0x155C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:49.67 mssearch.exe (0x1B2C) 0x155C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:49.82 mssearch.exe (0x1B2C) 0x155C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:49.84 mssearch.exe (0x1B2C) 0x155C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 0 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:49.89 mssearch.exe (0x1B2C) 0x155C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 0 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:49.90 mssearch.exe (0x1B2C) 0x0750 Search Server Common GatherStatus 0 Monitorable Advise status change 12, project AnchorProject, crawl -1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:51.42 mssearch.exe (0x1B2C) 0x1E4C Search Server Common GatherStatus 0 Monitorable Advise status change 4, project AnchorProject, crawl 772 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:51.00 mssearch.exe (0x1B2C) 0x1E4C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 0 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:51.42 mssearch.exe (0x1B2C) 0x1CCC Search Server Common GatherStatus 0 Monitorable Remove crawl 772 from inprogress queue - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:6722 03/15/2010 09:03:52.96 mssearch.exe (0x1B2C) 0x1CCC Search Server Common GatherStatus 0 Monitorable Insert crawl 773 to inprogress queue hr 0x00000000 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:6591 03/15/2010 09:03:52.96 mssearch.exe (0x1B2C) 0x1CCC Search Server Common GatherStatus 0 Monitorable Request Start Crawl 0, project AnchorProject, crawl 773 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:2875 03/15/2010 09:03:55.29 mssearch.exe (0x1B2C) 0x1CCC Search Server Common GatherStatus 0 Monitorable Unlock Queue, project AnchorProject - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:2922 03/15/2010 09:03:55.29 mssearch.exe (0x1B2C) 0x1CCC Search Server Common GatherStatus 0 Monitorable Removed start crawl request from Queue 0, crawl 773 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:2942 03/15/2010 09:03:55.29 mssearch.exe (0x1B2C) 0x1CCC Search Server Common GatherStatus 0 Monitorable Request Start Crawl 0, project AnchorProject, crawl 773 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:2875 03/15/2010 09:03:55.29 mssearch.exe (0x1B2C) 0x1CCC Search Server Common GatherStatus 0 Monitorable Advise status change 0, project AnchorProject, crawl 773 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:55.37 mssearch.exe (0x1B2C) 0x1CCC Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 0 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:55.37 mssearch.exe (0x1B2C) 0x0750 Search Server Common GatherStatus 0 Monitorable Advise status change 12, project AnchorProject, crawl -1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:56.71 mssearch.exe (0x1B2C) 0x1E4C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 0 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:56.78 mssearch.exe (0x1B2C) 0x0750 Search Server Common GatherStatus 0 Monitorable Advise status change 12, project AnchorProject, crawl -1 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:58.40 mssearch.exe (0x1B2C) 0x155C Search Server Common GathererSql 0 Monitorable CGatherer::LoadTransactionsFromCrawlInternal Flush anchor, count 0 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4943 03/15/2010 09:03:58.89 mssearch.exe (0x1B2C) 0x155C Search Server Common GatherStatus 0 Monitorable Advise status change 4, project AnchorProject, crawl 773 - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:4853 03/15/2010 09:03:58.89 mssearch.exe (0x1B2C) 0x1130 Search Server Common GatherStatus 0 Monitorable Remove crawl 773 from inprogress queue - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:6722 03/15/2010 09:03:58.89 mssearch.exe (0x1B2C) 0x1130 Search Server Common GatherStatus 0 Monitorable Unlock Queue, project AnchorProject - File:d:\office\source\search\search\gather\server\gatherobj.cxx Line:2922 What could be wrong here - any clues?

    Read the article

  • Problems setting NTP sever with w32tm for a DC that is a Hyper-V guest

    - by R.Tonheim
    Hello ! I have tried to sett my DC to get its time from several NTP severs. I follow this answer (http://serverfault.com/questions/24298/w32time-sync-problems-for-hyper-v-guests-w32time-event-ids-38-24-29-35/24299#24299) to do it. First I disable Time Synchronization in the Hyper-V Integration Services for each guest. Then restart the Windows Time serviceon the guest. I had before this used this command: w32tm /config /manualpeerlist:"ntp.uio.no;timekeeper. uio.no;nissen.uio.no;0.no.pool.ntp.org;1.no.pool.ntp.org;2.no.pool.ntp.org" /syn cfromflags:manual /reliable:yes /update And the cmd sad: The command completed successfully. But the time was still 10 min wrong... I run w32tm again after restarted the DC without it having any effect. The w32tm /query /status still say: "Source: Local CMOS Clock" FROM MY CMD: Microsoft Windows [Version 6.0.6002] Copyright (c) 2006 Microsoft Corporation. All rights reserved. C:\Users\Administrator.MHGw32tm /query /status Leap Indicator: 0(no warning) Stratum: 1 (primary reference - syncd by radio clock) Precision: -6 (15.625ms per tick) Root Delay: 0.0000000s Root Dispersion: 10.0000000s ReferenceId: 0x4C4F434C (source name: "LOCL") Last Successful Sync Time: 05.09.2009 20:06:21 Source: Local CMOS Clock Poll Interval: 6 (64s) C:\Users\Administrator.MHGw32tm /config /manualpeerlist:"ntp.uio.no;timekeeper. uio.no;nissen.uio.no;0.no.pool.ntp.org;1.no.pool.ntp.org;2.no.pool.ntp.org" /syn cfromflags:manual /reliable:yes /update The command completed successfully. C:\Users\Administrator.MHGw32tm /query /status Leap Indicator: 0(no warning) Stratum: 1 (primary reference - syncd by radio clock) Precision: -6 (15.625ms per tick) Root Delay: 0.0000000s Root Dispersion: 10.0000000s ReferenceId: 0x4C4F434C (source name: "LOCL") Last Successful Sync Time: 05.09.2009 20:06:21 Source: Local CMOS Clock Poll Interval: 6 (64s) C:\Users\Administrator.MHG

    Read the article

  • syspolicy_purge_history generates failed logins

    - by jbrown414
    I have a development server with 3 instances: Default, A and B. It is a physical server, non clustered. Whenever the syspolicy_purge_history job runs at 2 am, I get failed login alerts. Looking at the job steps, all are successfully completed. It appears that some point during the step "Erase Phantom System Health Records" is when the failed logins occur. syspolicy_purge_history on instance B works OK. syspolicy_purge_history on the Default instance seems to want to connect to instance B, resulting in: Error: 18456, Severity: 14, State: 11. Login failed for user 'Machinename\sqlsvc-B'. Reason: Token-based server access validation failed with an infrastructure error. Check for previous errors. [CLIENT: <local machine>] . No errors are reported by Powershell. syspolicy_purge_history on the A instance seems to want to connect to the Default instance resulting in Error: 18456, Severity: 14, State: 11. Login failed for user 'Machinename\sqlsvc-Default'. Reason: Token-based server access validation failed with an infrastructure error. Check for previous errors. [CLIENT: <local machine>] . Then it tries to connect to the B instance, resulting in Error: 18456, Severity: 14, State: 11. Login failed for user 'Machinename\sqlsvc-B'. Reason: Token-based server access validation failed with an infrastructure error. Check for previous errors. [CLIENT: <local machine>] . No errors are reported by Powershell. I tried the steps posted here hoping they would fix it. http://support.microsoft.com/kb/955726 But again, this is not a virtual server nor is it in a cluster. Do you have any suggestions? Thanks.

    Read the article

  • NetApp FAS 2040 LDAP Win2k8R2

    - by it_stuck
    I am trying to get my FAS2040 to action user lookups using LDAP, below is the filer configuration options: filer> options ldap ldap.ADdomain dc1.colour.domain.local ldap.base OU=Users,OU=something1,OU=something2,OU=darkside,DC=colour,DC=domain,DC=local ldap.base.group ldap.base.netgroup ldap.base.passwd ldap.enable on ldap.minimum_bind_level anonymous ldap.name domain-admin-account ldap.nssmap.attribute.gecos gecos ldap.nssmap.attribute.gidNumber gidNumber ldap.nssmap.attribute.groupname cn ldap.nssmap.attribute.homeDirectory homeDirectory ldap.nssmap.attribute.loginShell loginShell ldap.nssmap.attribute.memberNisNetgroup memberNisNetgroup ldap.nssmap.attribute.memberUid memberUid ldap.nssmap.attribute.netgroupname cn ldap.nssmap.attribute.nisNetgroupTriple nisNetgroupTriple ldap.nssmap.attribute.uid uid ldap.nssmap.attribute.uidNumber uidNumber ldap.nssmap.attribute.userPassword userPassword ldap.nssmap.objectClass.nisNetgroup nisNetgroup ldap.nssmap.objectClass.posixAccount posixAccount ldap.nssmap.objectClass.posixGroup posixGroup ldap.passwd ****** ldap.port 389 ldap.servers ldap.servers.preferred ldap.ssl.enable off ldap.timeout 20 ldap.usermap.attribute.unixaccount unixaccount ldap.usermap.attribute.windowsaccount sAMAccountName ldap.usermap.base ldap.usermap.enable on output of nsswitch.conf: hosts: files dns passwd: ldap files netgroup: ldap files group: ldap files shadow: files nis Error Message(s): [filer: auth.ldap.trace.LDAPConnection.statusMsg:info]: AUTH: TraceLDAPServer- Starting AD LDAP server address discovery for dc1.colour.domain.LOCAL. [filer: auth.ldap.trace.LDAPConnection.statusMsg:info]: AUTH: TraceLDAPServer- Found no AD LDAP server addresses using DNS site query (site). [filer: auth.ldap.trace.LDAPConnection.statusMsg:info]: AUTH: TraceLDAPServer- Found no AD LDAP server addresses using generic DNS query. Could not get passwd entry for name = <random user> the filer can ping the FQDN of dc1 the filer can ping the IP of dc1 the filer cannot ping "dc1" I'm not sure where I'm going wrong, so any pointers would be great.

    Read the article

  • MultiView 2000 terminal emulator not printing correctly to Generic/Text Printer on Windows 7

    - by FantaFan
    Guys & gals, Hope someone can shed some light on this. I am downloading reports from an AIX-based system by directing them to a TT printer which the terminal emulator (MultiView 2000) intercepts and directs to the default printer on the local system. This local printer is configured as a vanilla Generic/Text printer attached to a FILE port. When I print from AIX, the output is spooled down and the local printer prompts for a file name into which to save the file...but not under Windows 7. This has worked fine for many years, on both Win2K and WinXP. However, on Windows 7 the output gets spooled as a file into spool\PRINTERS (and looks as expected) but the print job then hangs with a status of "Error - Printing" and never prompts for a file name. I have to cancel the job. The Generic/Text printer works as expected with other applications. I have tried setting the printer to print directly rather than spooling but this only serves to hang the terminal session too. I've also tried to run the emulator in Windows 2000 Compatibility Mode and as Administrator in case it was something like that but with no luck. As you might expect, it does work fine in XP Mode (as long as I print to a printer defined therein and not the host's printer) but operationally this isn't going to be an option. Obviously this emulation software is a decade old (at least) and I could just cross/upgrade all the users (at a cost) but, before I do so, has anyone seen this sort of behaviour before and found some sort of fix? Remote OS: AIX 5 Client OS: Windows 7 Pro (32-bit) Printer: Generic/Text on a FILE port TE Software: MultiView 2000 (320-bit) Thanks in advance.

    Read the article

  • Cisco ASA 5505 allowing inbound ICMPv6

    - by Astron
    I am trying to allow inbound unsolicited ICMPv6 requests from an external link-local address to my outside (external) interfaces link-local address. I can ping (echo-request) the external address and receive a pong (echo-reply) but ICMPv6 messages initiated on the far side are dropped. I am running 9.0(1) in order to use some of the newer features. Does the Cisco ASA not allow unsolicited inbound requests from a link-local address? Should it matter if all ICMPv6 is allowed? Statements being denied: %ASA-3-313008: Denied IPv6-ICMP type=129, code=0 from fe80::XXXX:XXXX:XXXX:XXXX on interface outside %ASA-3-313008: Denied IPv6-ICMP type=131, code=0 from fe80::XXXX:XXXX:XXXX:XXXX on interface outside %ASA-3-313008: Denied IPv6-ICMP type=131, code=0 from fe80::XXXX:XXXX:XXXX:XXXX on interface outside %ASA-3-313008: Denied IPv6-ICMP type=136, code=0 from fe80::XXXX:XXXX:XXXX:XXXX on interface outside %ASA-3-313008: Denied IPv6-ICMP type=136, code=0 from fe80::XXXX:XXXX:XXXX:XXXX on interface outside %ASA-3-313008: Denied IPv6-ICMP type=136, code=0 from fe80::XXXX:XXXX:XXXX:XXXX on interface outside I created both an inbound ACL and ICMP permit statements: access-list OUTSIDE-IN extended permit icmp6 any any access-list OUTSIDE-IN extended permit icmp6 any any membership-report access-list OUTSIDE-IN extended permit icmp6 any any membership-report 0 access-list OUTSIDE-IN extended permit icmp6 any any echo-reply 0 access-list OUTSIDE-IN extended permit icmp6 any any echo-reply access-list OUTSIDE-IN extended permit icmp6 any interface outside membership-report access-list OUTSIDE-IN extended permit icmp6 any interface outside membership-report 0 access-list OUTSIDE-IN extended permit icmp6 any6 any6 echo-reply access-list OUTSIDE-IN extended permit icmp6 any6 any6 membership-report access-list OUTSIDE-IN extended permit icmp6 any6 any6 echo-reply 0 access-list OUTSIDE-IN extended permit icmp6 any6 any6 membership-report 0 snip access-group OUTSIDE-IN in interface outside ipv6 icmp permit any inside ipv6 icmp permit any membership-report outside ipv6 icmp permit any echo-reply outside ipv6 icmp permit any router-advertisement outside ipv6 icmp permit any neighbor-solicitation outside ipv6 icmp permit any neighbor-advertisement outside ipv6 icmp permit any outside

    Read the article

  • Generic/Text Printer on Windows 7 not prompting for file name

    - by FantaFan
    Guys & gals, Hope someone can shed some light on this. I am downloading reports from an AIX-based system by directing them to a TT printer which the terminal emulator (MultiView 2000) intercepts and directs to the default printer on the local system. This local printer is configured as a vanilla Generic/Text printer attached to a FILE port. When I print from AIX, the output is spooled down and the local printer prompts for a file name into which to save the file...but not under Windows 7. This has worked fine for many years, on both Win2K and WinXP. However, on Windows 7 the output gets spooled as a file into spool\PRINTERS (and looks as expected) but the print job then hangs with a status of "Error - Printing" and never prompts for a file name. I have to cancel the job. The Generic/Text printer works as expected with other applications. I have tried setting the printer to print directly rather than spooling but this only serves to hang the terminal session too. I've also tried to run the emulator in Windows 2000 Compatibility Mode and as Administrator in case it was something like that but with no luck. As you might expect, it does work fine in XP Mode (as long as I print to a printer defined therein and not the host's printer) but operationally this isn't going to be an option. Obviously this emulation software is a decade old (at least) and I could just cross/upgrade all the users (at a cost) but, before I do so, has anyone seen this sort of behaviour before and found some sort of fix? Remote OS: AIX 5 Client OS: Windows 7 Pro (32-bit) Printer: Generic/Text on a FILE port TE Software: MultiView 2000 (32-bit) Thanks in advance.

    Read the article

  • Remote App Authentication Error (Code:0x507)

    - by CMK
    Hi I'm trying to get RDP services running with Windows 2008 R2. I'm at a WINXP SP3 client that was modified to run RDP with NLA. When I start the client connect to the local DC and get an authentification error (Code 0x507). I've already done the following: • Server Setup to run as a standalone local "DC" to provide Terminal services to a single application. Remote Desktop Session Host CAL License is running & operational, RD Gateway Manager w/ Local Server RAP & CAP running NLA & operational etc..... Server has NLA & temporary use of port 3389 (which is directly connected to and accessible from the internet (I am planning to change the port to 443, but want to get the current system running first). • XP Client(s): RDP-Version on win xp clients is 6.1 If had SP2, then added SP3 and edited the registry settings to allow NLA, by: Click Start, click Run, type regedit, and then press ENTER. In the navigation pane, locate and then click the following registry subkey: HKEY_LOCAL_MACHINE \SYSTEM\CurrentControlSet\Control\Lsa In the details pane, right-click Security Packages, and then click Modify. In the Value data box, type tspkg. Leave any data that is specific to other SSPs, and then click OK. In the navigation pane, locate and then click the following registry subkey: HKEY_LOCAL_MACHINE \SYSTEM\CurrentControlSet\Control\SecurityProviders In the details pane, right-click SecurityProviders, and then click Modify. In the Value data box, type credssp.dll. Leave any data that is specific to other SSPs, and then click OK. Exit Registry Editor. Restart the computer.

    Read the article

  • Can't get my OpenVpn client to connect

    - by Larry
    Hi Guys, I am trying to setup a test vpn between my home desktop and my laptop. So far I have got the server on the desktop to connect fine but I can not get my laptop to finish the connection. I have tried several different configurations and they all give me the same result. Obviously it has nothing to do with my Client configuration but possibly something on my laptop? Here is the message I get in the log when it stops then times out and restarts. Mon Oct 18 20:10:55 2010 UDPv4 link local: [undef] Mon Oct 18 20:10:55 2010 UDPv4 link remote: 74.190.29.236:1194 Mon Oct 18 20:11:55 2010 TLS Error: TLS key negotiation failed to occur within 60 seconds (check your network connectivity) Mon Oct 18 20:11:55 2010 TLS Error: TLS handshake failed here are my configurations server.ovpn port 1194 proto udp dev tun ca ca.crt cert server.crt key server.key dh dh1024.pem server 10.8.0.1 255.255.255.252 ifconfig-pool-persist ipp.txt push "route 10.0.0.1 255.255.255.0" push "dhcp-option WINS 10.0.0.5" push "dhcp-option DNS 10.0.0.5" push "dhcp-option DOMAIN acme.com.local" keepalive 10 120 comp-lzo max-clients 1 persist-key persist-tun status openvpn-status.log verb 3 LArry.ovpn client proto udp dev tun remote doublel.hopto.org 1194 resolv-retry infinite nobind persist-key persist-tun ca ca.crt cert client1.crt key client1.key comp-lzo verb 3 dev tun local 206.162.148.9 remote 134.28.54.2 ifconfig 192.168.99.1 192.168.99.2 route 10.0.0.0 255.0.0.0 192.168.99.2 I just need a simple vpn for one user. Am I headed down the right path? Thanks, Larry

    Read the article

  • Windows Start Menu Not Staying on Top

    - by Jeff Rapp
    Hey everyone. I've had this problem since Windows Vista. I did a clean install with Windows 7 and hoped it would fix the problem. Also swapped out the video card just to rule out a strange driver issue. Here's what's happening. After running for some period of time (usually a few hours), the Start button/orb will loose it's "Chrome" and turn into a plain button that just says "Start." It will work fine for a while, but then the start menu will just stop showing. Additionally, when I hit Win+D to show the desktop, the entire taskbar completely disappears. I can get it back usually by moving/minimizing windows that may be overlapping where the start menu should show. Otherwise, it requires either a full reboot or I'll end up killing & restarting the explorer.exe process. I realize that this is a strange issue - I took a video of it http://www.youtube.com/watch?v=0B3WwT0uyr4 Thanks! --Edit-- Here's my HijackThis log: Logfile of Trend Micro HijackThis v2.0.3 (BETA) Scan saved at 4:19:00 PM, on 12/16/2009 Platform: Unknown Windows (WinNT 6.01.3504) MSIE: Internet Explorer v8.00 (8.00.7600.16385) Boot mode: Normal Running processes: C:\Program Files (x86)\Pantone\hueyPRO\hueyPROTray.exe C:\Program Files (x86)\Adobe\Acrobat 9.0\Acrobat\acrotray.exe C:\Program Files (x86)\iTunes\iTunesHelper.exe C:\Program Files (x86)\Java\jre6\bin\jusched.exe C:\Program Files (x86)\MagicDisc\MagicDisc.exe C:\Program Files (x86)\Trillian\trillian.exe C:\Program Files (x86)\Microsoft Visual Studio 9.0\Common7\IDE\devenv.exe C:\Program Files (x86)\Microsoft SQL Server\100\Tools\Binn\VSShell\Common7\IDE\Ssms.exe C:\Program Files (x86)\Microsoft Visual Studio 9.0\Common7\IDE\devenv.exe C:\Program Files (x86)\Microsoft Visual Studio 9.0\Common7\IDE\devenv.exe C:\Program Files (x86)\Microsoft Visual Studio 9.0\Common7\IDE\devenv.exe C:\Program Files (x86)\Common Files\Microsoft Shared\DevServer\9.0\WebDev.WebServer.EXE C:\Program Files (x86)\Notepad++\notepad++.exe C:\Program Files (x86)\Fiddler2\Fiddler.exe C:\Program Files (x86)\Microsoft Visual Studio 9.0\Common7\IDE\mspdbsrv.exe C:\Program Files (x86)\iTunes\iTunes.exe C:\Program Files (x86)\Adobe\Adobe Illustrator CS4\Support Files\Contents\Windows\Illustrator.exe C:\Program Files (x86)\ColorPic 4.1\ColorPic.exe C:\Program Files (x86)\Adobe\Acrobat 9.0\Acrobat\Acrobat.exe C:\Program Files (x86)\Common Files\Microsoft Shared\Help 9\dexplore.exe C:\Program Files (x86)\Common Files\Microsoft Shared\Help 9\dexplore.exe C:\Program Files (x86)\Internet Explorer\IEXPLORE.EXE C:\Program Files (x86)\Internet Explorer\IEXPLORE.EXE C:\Program Files (x86)\Microsoft Visual Studio 9.0\Common7\IDE\devenv.exe C:\Program Files (x86)\eBay\Blackthorne\bin\BT.exe C:\Program Files (x86)\Internet Explorer\IEXPLORE.EXE C:\Program Files (x86)\CamStudio\Recorder.exe C:\Program Files (x86)\CamStudio\Playplus.exe C:\Program Files (x86)\Mozilla Firefox 3.6 Beta 3\firefox.exe C:\Program Files (x86)\CamStudio\Playplus.exe C:\Program Files (x86)\PuTTY\putty.exe C:\Program Files (x86)\CamStudio\Playplus.exe C:\Program Files (x86)\CamStudio\Playplus.exe C:\Program Files (x86)\TrendMicro\HiJackThis\HiJackThis.exe R1 - HKCU\Software\Microsoft\Internet Explorer\Main,Search Page = http://go.microsoft.com/fwlink/?LinkId=54896 R0 - HKCU\Software\Microsoft\Internet Explorer\Main,Start Page = http://go.microsoft.com/fwlink/?LinkId=69157 R1 - HKLM\Software\Microsoft\Internet Explorer\Main,Default_Page_URL = http://go.microsoft.com/fwlink/?LinkId=69157 R1 - HKLM\Software\Microsoft\Internet Explorer\Main,Default_Search_URL = http://go.microsoft.com/fwlink/?LinkId=54896 R1 - HKLM\Software\Microsoft\Internet Explorer\Main,Search Page = http://go.microsoft.com/fwlink/?LinkId=54896 R0 - HKLM\Software\Microsoft\Internet Explorer\Main,Start Page = http://go.microsoft.com/fwlink/?LinkId=69157 R0 - HKLM\Software\Microsoft\Internet Explorer\Search,SearchAssistant = R0 - HKLM\Software\Microsoft\Internet Explorer\Search,CustomizeSearch = R0 - HKLM\Software\Microsoft\Internet Explorer\Main,Local Page = C:\Windows\SysWOW64\blank.htm R0 - HKCU\Software\Microsoft\Internet Explorer\Toolbar,LinksFolderName = F2 - REG:system.ini: UserInit=userinit.exe O2 - BHO: ContributeBHO Class - {074C1DC5-9320-4A9A-947D-C042949C6216} - C:\Program Files (x86)\Adobe\/Adobe Contribute CS4/contributeieplugin.dll O2 - BHO: AcroIEHelperStub - {18DF081C-E8AD-4283-A596-FA578C2EBDC3} - C:\Program Files (x86)\Common Files\Adobe\Acrobat\ActiveX\AcroIEHelperShim.dll O2 - BHO: Groove GFS Browser Helper - {72853161-30C5-4D22-B7F9-0BBC1D38A37E} - C:\PROGRA~2\MICROS~1\Office14\GROOVEEX.DLL O2 - BHO: Windows Live Sign-in Helper - {9030D464-4C02-4ABF-8ECC-5164760863C6} - C:\Program Files (x86)\Common Files\Microsoft Shared\Windows Live\WindowsLiveLogin.dll O2 - BHO: Adobe PDF Conversion Toolbar Helper - {AE7CD045-E861-484f-8273-0445EE161910} - C:\Program Files (x86)\Common Files\Adobe\Acrobat\ActiveX\AcroIEFavClient.dll O2 - BHO: URLRedirectionBHO - {B4F3A835-0E21-4959-BA22-42B3008E02FF} - C:\PROGRA~2\MICROS~1\Office14\URLREDIR.DLL O2 - BHO: Java(tm) Plug-In 2 SSV Helper - {DBC80044-A445-435b-BC74-9C25C1C588A9} - C:\Program Files (x86)\Java\jre6\bin\jp2ssv.dll O2 - BHO: SmartSelect - {F4971EE7-DAA0-4053-9964-665D8EE6A077} - C:\Program Files (x86)\Common Files\Adobe\Acrobat\ActiveX\AcroIEFavClient.dll O3 - Toolbar: Adobe PDF - {47833539-D0C5-4125-9FA8-0819E2EAAC93} - C:\Program Files (x86)\Common Files\Adobe\Acrobat\ActiveX\AcroIEFavClient.dll O3 - Toolbar: Contribute Toolbar - {517BDDE4-E3A7-4570-B21E-2B52B6139FC7} - C:\Program Files (x86)\Adobe\/Adobe Contribute CS4/contributeieplugin.dll O4 - HKLM\..\Run: [AdobeCS4ServiceManager] "C:\Program Files (x86)\Common Files\Adobe\CS4ServiceManager\CS4ServiceManager.exe" -launchedbylogin O4 - HKLM\..\Run: [Adobe Acrobat Speed Launcher] "C:\Program Files (x86)\Adobe\Acrobat 9.0\Acrobat\Acrobat_sl.exe" O4 - HKLM\..\Run: [Acrobat Assistant 8.0] "C:\Program Files (x86)\Adobe\Acrobat 9.0\Acrobat\Acrotray.exe" O4 - HKLM\..\Run: [Adobe_ID0ENQBO] C:\PROGRA~2\COMMON~1\Adobe\ADOBEV~1\Server\bin\VERSIO~2.EXE O4 - HKLM\..\Run: [QuickTime Task] "C:\Program Files (x86)\QuickTime\QTTask.exe" -atboottime O4 - HKLM\..\Run: [iTunesHelper] "C:\Program Files (x86)\iTunes\iTunesHelper.exe" O4 - HKLM\..\Run: [SunJavaUpdateSched] "C:\Program Files (x86)\Java\jre6\bin\jusched.exe" O4 - HKUS\S-1-5-19\..\Run: [Sidebar] %ProgramFiles%\Windows Sidebar\Sidebar.exe /autoRun (User 'LOCAL SERVICE') O4 - HKUS\S-1-5-19\..\RunOnce: [mctadmin] C:\Windows\System32\mctadmin.exe (User 'LOCAL SERVICE') O4 - HKUS\S-1-5-20\..\Run: [Sidebar] %ProgramFiles%\Windows Sidebar\Sidebar.exe /autoRun (User 'NETWORK SERVICE') O4 - HKUS\S-1-5-20\..\RunOnce: [mctadmin] C:\Windows\System32\mctadmin.exe (User 'NETWORK SERVICE') O4 - Startup: ChatNowDesktop.appref-ms O4 - Startup: MagicDisc.lnk = C:\Program Files (x86)\MagicDisc\MagicDisc.exe O4 - Startup: Trillian.lnk = C:\Program Files (x86)\Trillian\trillian.exe O4 - Global Startup: Digsby.lnk = C:\Program Files (x86)\Digsby\digsby.exe O4 - Global Startup: hueyPROTray.lnk = C:\Program Files (x86)\Pantone\hueyPRO\hueyPROTray.exe O4 - Global Startup: OfficeSAS.lnk = ? O8 - Extra context menu item: Append Link Target to Existing PDF - res://C:\Program Files (x86)\Common Files\Adobe\Acrobat\ActiveX\AcroIEFavClient.dll/AcroIEAppendSelLinks.html O8 - Extra context menu item: Append to Existing PDF - res://C:\Program Files (x86)\Common Files\Adobe\Acrobat\ActiveX\AcroIEFavClient.dll/AcroIEAppend.html O8 - Extra context menu item: Convert Link Target to Adobe PDF - res://C:\Program Files (x86)\Common Files\Adobe\Acrobat\ActiveX\AcroIEFavClient.dll/AcroIECaptureSelLinks.html O8 - Extra context menu item: Convert to Adobe PDF - res://C:\Program Files (x86)\Common Files\Adobe\Acrobat\ActiveX\AcroIEFavClient.dll/AcroIECapture.html O8 - Extra context menu item: E&xport to Microsoft Excel - res://C:\PROGRA~1\MICROS~1\Office14\EXCEL.EXE/3000 O8 - Extra context menu item: S&end to OneNote - res://C:\PROGRA~1\MICROS~1\Office14\ONBttnIE.dll/105 O9 - Extra button: Send to OneNote - {2670000A-7350-4f3c-8081-5663EE0C6C49} - C:\Program Files (x86)\Microsoft Office\Office14\ONBttnIE.dll O9 - Extra 'Tools' menuitem: Se&nd to OneNote - {2670000A-7350-4f3c-8081-5663EE0C6C49} - C:\Program Files (x86)\Microsoft Office\Office14\ONBttnIE.dll O9 - Extra button: OneNote Lin&ked Notes - {789FE86F-6FC4-46A1-9849-EDE0DB0C95CA} - C:\Program Files (x86)\Microsoft Office\Office14\ONBttnIELinkedNotes.dll O9 - Extra 'Tools' menuitem: OneNote Lin&ked Notes - {789FE86F-6FC4-46A1-9849-EDE0DB0C95CA} - C:\Program Files (x86)\Microsoft Office\Office14\ONBttnIELinkedNotes.dll O9 - Extra button: Fiddler2 - {CF819DA3-9882-4944-ADF5-6EF17ECF3C6E} - "C:\Program Files (x86)\Fiddler2\Fiddler.exe" (file missing) O9 - Extra 'Tools' menuitem: Fiddler2 - {CF819DA3-9882-4944-ADF5-6EF17ECF3C6E} - "C:\Program Files (x86)\Fiddler2\Fiddler.exe" (file missing) O13 - Gopher Prefix: O16 - DPF: {5554DCB0-700B-498D-9B58-4E40E5814405} (RSClientPrint 2008 Class) - http://reportserver/Reports/Reserved.ReportViewerWebControl.axd?ReportSession=oxadkhfvfvt1hzf2eh3y1ay2&ControlID=b89e27f15e734f3faee1308eebdfab2a&Culture=1033&UICulture=9&ReportStack=1&OpType=PrintCab&Arch=X86 O16 - DPF: {82774781-8F4E-11D1-AB1C-0000F8773BF0} (DLC Class) - https://transfers.ds.microsoft.com/FTM/TransferSource/grTransferCtrl.cab O16 - DPF: {D27CDB6E-AE6D-11CF-96B8-444553540000} (Shockwave Flash Object) - http://fpdownload2.macromedia.com/get/shockwave/cabs/flash/swflash.cab O17 - HKLM\System\CCS\Services\Tcpip\Parameters: Domain = LapkoSoft.local O17 - HKLM\System\CCS\Services\Tcpip\..\{5992B87A-643B-4385-A914-249B98BF7129}: NameServer = 192.168.1.10 O17 - HKLM\System\CS1\Services\Tcpip\Parameters: Domain = LapkoSoft.local O17 - HKLM\System\CS2\Services\Tcpip\Parameters: Domain = LapkoSoft.local O18 - Filter hijack: text/xml - {807573E5-5146-11D5-A672-00B0D022E945} - C:\Program Files (x86)\Common Files\Microsoft Shared\OFFICE14\MSOXMLMF.DLL O23 - Service: Adobe Version Cue CS4 - Adobe Systems Incorporated - C:\Program Files (x86)\Common Files\Adobe\Adobe Version Cue CS4\Server\bin\VersionCueCS4.exe O23 - Service: @%SystemRoot%\system32\Alg.exe,-112 (ALG) - Unknown owner - C:\Windows\System32\alg.exe (file missing) O23 - Service: Apple Mobile Device - Apple Inc. - C:\Program Files (x86)\Common Files\Apple\Mobile Device Support\bin\AppleMobileDeviceService.exe O23 - Service: ASP.NET State Service (aspnet_state) - Unknown owner - C:\Windows\Microsoft.NET\Framework\v2.0.50727\aspnet_state.exe (file missing) O23 - Service: Bonjour Service - Apple Inc. - C:\Program Files (x86)\Bonjour\mDNSResponder.exe O23 - Service: @%SystemRoot%\system32\efssvc.dll,-100 (EFS) - Unknown owner - C:\Windows\System32\lsass.exe (file missing) O23 - Service: @%systemroot%\system32\fxsresm.dll,-118 (Fax) - Unknown owner - C:\Windows\system32\fxssvc.exe (file missing) O23 - Service: FLEXnet Licensing Service - Acresso Software Inc. - C:\Program Files (x86)\Common Files\Macrovision Shared\FLEXnet Publisher\FNPLicensingService.exe O23 - Service: FLEXnet Licensing Service 64 - Acresso Software Inc. - C:\Program Files\Common Files\Macrovision Shared\FLEXnet Publisher\FNPLicensingService64.exe O23 - Service: @%windir%\system32\inetsrv\iisres.dll,-30007 (IISADMIN) - Unknown owner - C:\Windows\system32\inetsrv\inetinfo.exe (file missing) O23 - Service: iPod Service - Apple Inc. - C:\Program Files\iPod\bin\iPodService.exe O23 - Service: @keyiso.dll,-100 (KeyIso) - Unknown owner - C:\Windows\system32\lsass.exe (file missing) O23 - Service: @comres.dll,-2797 (MSDTC) - Unknown owner - C:\Windows\System32\msdtc.exe (file missing) O23 - Service: @%SystemRoot%\System32\netlogon.dll,-102 (Netlogon) - Unknown owner - C:\Windows\system32\lsass.exe (file missing) O23 - Service: NVIDIA Performance Driver Service - Unknown owner - C:\Program Files\NVIDIA Corporation\Performance Drivers\nvPDsvc.exe O23 - Service: NVIDIA Display Driver Service (nvsvc) - Unknown owner - C:\Windows\system32\nvvsvc.exe (file missing) O23 - Service: @%systemroot%\system32\psbase.dll,-300 (ProtectedStorage) - Unknown owner - C:\Windows\system32\lsass.exe (file missing) O23 - Service: @%systemroot%\system32\Locator.exe,-2 (RpcLocator) - Unknown owner - C:\Windows\system32\locator.exe (file missing) O23 - Service: @%SystemRoot%\system32\samsrv.dll,-1 (SamSs) - Unknown owner - C:\Windows\system32\lsass.exe (file missing) O23 - Service: @%SystemRoot%\system32\snmptrap.exe,-3 (SNMPTRAP) - Unknown owner - C:\Windows\System32\snmptrap.exe (file missing) O23 - Service: @%systemroot%\system32\spoolsv.exe,-1 (Spooler) - Unknown owner - C:\Windows\System32\spoolsv.exe (file missing) O23 - Service: @%SystemRoot%\system32\sppsvc.exe,-101 (sppsvc) - Unknown owner - C:\Windows\system32\sppsvc.exe (file missing) O23 - Service: TeamViewer 5 (TeamViewer5) - TeamViewer GmbH - C:\Program Files (x86)\TeamViewer\Version5\TeamViewer_Service.exe O23 - Service: @%SystemRoot%\system32\ui0detect.exe,-101 (UI0Detect) - Unknown owner - C:\Windows\system32\UI0Detect.exe (file missing) O23 - Service: @%SystemRoot%\system32\vaultsvc.dll,-1003 (VaultSvc) - Unknown owner - C:\Windows\system32\lsass.exe (file missing) O23 - Service: @%SystemRoot%\system32\vds.exe,-100 (vds) - Unknown owner - C:\Windows\System32\vds.exe (file missing) O23 - Service: @%systemroot%\system32\vssvc.exe,-102 (VSS) - Unknown owner - C:\Windows\system32\vssvc.exe (file missing) O23 - Service: @%systemroot%\system32\wbengine.exe,-104 (wbengine) - Unknown owner - C:\Windows\system32\wbengine.exe (file missing) O23 - Service: @%Systemroot%\system32\wbem\wmiapsrv.exe,-110 (wmiApSrv) - Unknown owner - C:\Windows\system32\wbem\WmiApSrv.exe (file missing) O23 - Service: @%PROGRAMFILES%\Windows Media Player\wmpnetwk.exe,-101 (WMPNetworkSvc) - Unknown owner - C:\Program Files (x86)\Windows Media Player\wmpnetwk.exe (file missing)

    Read the article

  • Getting SMB file shares working over a PPTP VPN

    - by Ben Scott
    I'm having issues getting SMB file shares working over a PPTP VPN. The server setup consists of a security device (DrayTek V3300) which passes the PPTP authentication to a SBS2003 server running RRAS. The server is the DC and provides DNS and WINS, the single NIC's name server is set to the NIC's IP (192.168...), and DHCP on the DrayTek sets the server IP as the DNS. If I create a new VPN connection in Win7, leaving everything as default apart from the server, username, password and domain, I can: ping everything by IP address resolve IPs with nslookup using their fully-qualified name, as in nslookup fileserver.mydomain.local ping machines by fully-qualified name, as in ping fileserver.mydomain.local However if I try to access a file share: within Explorer, I get "Windows cannot access ..." with "Error code: 0x80004005 Unspecified Error", using net use z: \\fileserver.mydomain.local\share, I get "System error 53 has occurred. The network path was not found." If I add the machine name to my HOSTS file I can use the file share, which is my last-ditch workaround, but I have a number of VPN users and would rather a solution that doesn't involve me trying to hand-edit system files on computers half a country away. If I set the WINS server explicitly in the connection's IPv4 settings I don't have to use the FQN to ping the machine, but that doesn't change anything else. EDIT: The PC I'm having the issue on is running Win 7 Home Premium. After more testing I actually have two other PCs that work, one W7HP, one XP Home, and another Vista PC that doesn't work (not tested as much as the others), all four on the same internet connection (behind the same router). All of them were tested with a straight-forward, all defaults, new VPN configuration.

    Read the article

  • NetApp FAS 2040 LDAP Win2k8R2

    - by it_stuck
    I am trying to get my FAS2040 to action user lookups using LDAP, below is the filer configuration options: filer> options ldap ldap.ADdomain dc1.colour.domain.local ldap.base OU=Users,OU=something1,OU=something2,OU=darkside,DC=colour,DC=domain,DC=local ldap.base.group ldap.base.netgroup ldap.base.passwd ldap.enable on ldap.minimum_bind_level anonymous ldap.name domain-admin-account ldap.nssmap.attribute.gecos gecos ldap.nssmap.attribute.gidNumber gidNumber ldap.nssmap.attribute.groupname cn ldap.nssmap.attribute.homeDirectory homeDirectory ldap.nssmap.attribute.loginShell loginShell ldap.nssmap.attribute.memberNisNetgroup memberNisNetgroup ldap.nssmap.attribute.memberUid memberUid ldap.nssmap.attribute.netgroupname cn ldap.nssmap.attribute.nisNetgroupTriple nisNetgroupTriple ldap.nssmap.attribute.uid uid ldap.nssmap.attribute.uidNumber uidNumber ldap.nssmap.attribute.userPassword userPassword ldap.nssmap.objectClass.nisNetgroup nisNetgroup ldap.nssmap.objectClass.posixAccount posixAccount ldap.nssmap.objectClass.posixGroup posixGroup ldap.passwd ****** ldap.port 389 ldap.servers ldap.servers.preferred ldap.ssl.enable off ldap.timeout 20 ldap.usermap.attribute.unixaccount unixaccount ldap.usermap.attribute.windowsaccount sAMAccountName ldap.usermap.base ldap.usermap.enable on output of nsswitch.conf: hosts: files dns passwd: ldap files netgroup: ldap files group: ldap files shadow: files nis Error Message(s): [filer: auth.ldap.trace.LDAPConnection.statusMsg:info]: AUTH: TraceLDAPServer- Starting AD LDAP server address discovery for dc1.colour.domain.LOCAL. [filer: auth.ldap.trace.LDAPConnection.statusMsg:info]: AUTH: TraceLDAPServer- Found no AD LDAP server addresses using DNS site query (site). [filer: auth.ldap.trace.LDAPConnection.statusMsg:info]: AUTH: TraceLDAPServer- Found no AD LDAP server addresses using generic DNS query. Could not get passwd entry for name = <random user> the filer can ping the FQDN of dc1 the filer can ping the IP of dc1 the filer cannot ping "dc1" I'm not sure where I'm going wrong, so any pointers would be great.

    Read the article

  • SQL 2008 SP2 RsClientPrint ActiveX - "Unable to load client print control"

    - by Miles
    We recently updated our SQL 2008 server to use SP 2 and its causing a few headaches. We use SSRS on this server and when a client tries to print a report by the built-in print function, we're needing to download the RsClientPrint ActiveX control from the server from the client gets the following error Unable to load client print control. We have about 700 computers that are needing this fixed and I've followed the instructions found on the following URL: http://www.kodyaz.com/articles/client-side-printing-silent-deployment-of-rsclientPrint.aspx We have two issues: Most of the users who will be using this ActiveX control are not local administrators so they will not be able to install the control themselves Since there are so many computers, this has to be done silently behind the scenes run by a local admin account After following the information from the link above, we're able to put the files in the C:\Windows\System32 folder and register the DLL but we still get the same problem. The only small thing I've noticed is that in the HTML for the report page, everything that references a version is referencing version 2007.100.4000.00 and the version of the DLL that I pulled from the report server is 2007.100.1600.22. Also, for some clients that are local administrators, they are prompted every time to install the ActiveX control when they click print. This works successfully but we can't have the user asked if they want to install the same control every time they need to print.

    Read the article

  • Exchange 2003: Fresh install, couple noob questions.

    - by Eli
    Hi All, Thanks for reading! I have a small network set up for a local office here, and have a fresh install of Exchange 2003 on our sole-server PDC. The network uses one domain, call it ourdomain.net, which is DNSed locally, but not DNSed for the actual domain, so ourdomain.net works from within the network, but from outside, it's just pointed to some domain parking. I have a completely different domain, call it emaildomain.com, which is currently setup for our website and email, which is hosted with a standard hosting company. We've been using a combination of Thunderbird and Outlook (with local .pst files) for email. I've been asked to setup Exchange to work with our email, but am not familiar with it. The install seems to have gone just fine. The question is: How do I get email from a domain outside our network to work with the exchange server? Do I need to move the email for that domain to point to our local server (I so hope not!), or can I just set exchange so somehow slurp mail from the existing mailboxes on our host for that domain's mail? Or are there better ideas I don't know to ask for? Any help very appreciated - thanks!

    Read the article

  • Ipsec config problem // openswan

    - by user90696
    I try to configure Ipsec on server with openswan as client. But receive error - possible, it's auth error. What I wrote wrong in config ? Thank you for answers. #1: STATE_MAIN_I2: sent MI2, expecting MR2 003 "f-net" #1: received Vendor ID payload [Cisco-Unity] 003 "f-net" #1: received Vendor ID payload [Dead Peer Detection] 003 "f-net" #1: ignoring unknown Vendor ID payload [ca917959574c7d5aed4222a9df367018] 003 "f-net" #1: received Vendor ID payload [XAUTH] 108 "f-net" #1: STATE_MAIN_I3: sent MI3, expecting MR3 003 "f-net" #1: discarding duplicate packet; already STATE_MAIN_I3 010 "f-net" #1: STATE_MAIN_I3: retransmission; will wait 20s for response 003 "f-net" #1: discarding duplicate packet; already STATE_MAIN_I3 003 "f-net" #1: discarding duplicate packet; already STATE_MAIN_I3 003 "f-net" #1: discarding duplicate packet; already STATE_MAIN_I3 010 "f-net" #1: STATE_MAIN_I3: retransmission; will wait 40s for response 031 "f-net" #1: max number of retransmissions (2) reached STATE_MAIN_I3. Possible authentication failure: no acceptable response to our first encrypted message 000 "f-net" #1: starting keying attempt 2 of at most 3, but releasing whack other side - Cisco ASA. parameters for my connection on our Linux server : VPN Gateway 8.*.*.* (Cisco ) Phase 1 Exchange Type Main Mode Identification Type IP Address Local ID 4.*.*.* (our Linux server IP) Remote ID 8.*.*.* (VPN server IP) Authentication PSK Pre Shared Key Diffie-Hellman Key Group DH 5 (1536 bit) or DH 2 (1024 bit) Encryption Algorithm AES 256 HMAC Function SHA-1 Lifetime 86.400 seconds / no volume limit Phase 2 Security Protocol ESP Connection Mode Tunnel Encryption Algorithm AES 256 HMAC Function SHA-1 Lifetime 3600 seconds / 4.608.000 kilobytes DPD / IKE Keepalive 15 seconds PFS off Remote Network 192.168.100.0/24 Local Network 1 10.0.0.0/16 ............... Local Network 5 current openswan config : # config setup klipsdebug=all plutodebug="control parsing" protostack=netkey nat_traversal=no virtual_private=%v4:10.0.0.0/8,%v4:192.168.0.0/16,%v4:172.16.0.0/12 oe=off nhelpers=0 conn f-net type=tunnel keyexchange=ike authby=secret auth=esp esp=aes256-sha1 keyingtries=3 pfs=no aggrmode=no keylife=3600s ike=aes256-sha1-modp1024 # left=4.*.*.* leftsubnet=10.0.0.0/16 leftid=4.*.*.* leftnexthop=%defaultroute right=8.*.*.* rightsubnet=192.168.100.0/24 rightid=8.*.*.* rightnexthop=%defaultroute auto=add

    Read the article

< Previous Page | 164 165 166 167 168 169 170 171 172 173 174 175  | Next Page >