Search Results

Search found 12681 results on 508 pages for 'logical drive'.

Page 169/508 | < Previous Page | 165 166 167 168 169 170 171 172 173 174 175 176  | Next Page >

  • File corruption (bad checksums) in large files copied to VMware guest

    - by AllanA
    In setting up a development lab, I've got a desktop system running ESXi 4.1.0 (free license) on SATA RAID 0 (already purchased and configured when I started this job; I'm open to hardware input as it pertains to my problem.) Its guests so far include two Win2008 Server R2 64-bit VMs and on Ubuntu 10.04 64-bit VM. I'm installing onto the Windows servers. We've been copying off some fairly large files (over a gigabyte) for an installation, hoping to install more quickly from a (virtual) hard drive than from the network for from BD-ROM. The problem is that they keep coming up with different checksums from the originals. The file sizes are the same, but md5sum reports different numbers (and so does the installer, as it refuses to continue when the checksums don't match.) I've tried copying directly from the BD-ROM (attaching the OS drive to the host system's physical drive). I've tried copying the large files onto a co-worker's Windows machine from his Blu-Ray drive; when I do that, the checksums match. But when I copy from his machine to the VM guest over a network share, the checksums no longer match. Thinking this meant a corrupt destination drive, I deleted it in vSphere and added another freshly created drive. The problem persists. I'm not sure what to try next.

    Read the article

  • What software will tell me if I've already downloaded a video? [closed]

    - by dave
    (I use Linux KNOPPIX (distro 7.0.2, ver 3.3.7) on hard drive.) I download videos of TV programs from the 60s and 70s (mainly from youtube). I copy the youtube URL then paste it into www.keepvid.com to download it (usually .mp4 format). Having now got dozens of such video files (and growing) on my hard drive, I'd like to organise them. WHAT I'D LIKE TO DO IS: Say I find a new vid (of a TV prog) on youtube (or another site), and I'm about to download it. It's possible that I've WATCHED IT BEFORE but have forgotten. So is there software out there that I can run which will do the following: Check for me if I've ALREADY WATCHED the vid that I'm about to download. At the moment, once I've watched a vid on my hard drive, I move the file to another directory called "Watched". But this of course doesn't alert me in the immediate way that I want. . It would crudely suffice, if the software told me AFTER I've downloaded the vid, if I've ALREADY WATCHED it (ie if it's already in my "Watched" directory, or perhaps in a "watched" list). I sometimes alter the filename of the original video file on hard drive, so this might spoil a comparison. If the software alerts me to the fact that I've already watched the vid (preferably BEFORE I download it), then this will allow me to confidently download only new vids that I haven't watched before, and save me duplicating my effort. I'd be most grateful if anyone can suggest such a piece of software, or an alternative solution. I'll be honest, I avoid software that infringes your privacy and control - you know, software that automatically does things behind your back, like upgrades itself over the internet, puts things on your hard drive that you didn't ask for, or sends information from your hard drive to websites.

    Read the article

  • RHEL - blocked FC remote port time out: saving binding

    - by Dev G
    My Server went into a faulty state since the database could not write on the partition. I found out that the partition went into Read Only mode. Finally to fix it, I had to do a hard reboot. Linux 2.6.18-164.el5PAE #1 SMP Tue Aug 18 15:59:11 EDT 2009 i686 i686 i386 GNU/Linux /var/log/messages Oct 31 00:56:45 ota3g1 Had[17275]: VCS ERROR V-16-1-10214 Concurrency Violation:CurrentCount increased above 1 for failover group sg_network Oct 31 00:57:05 ota3g1 Had[17275]: VCS CRITICAL V-16-1-50086 CPU usage on ota3g1.mtsallstream.com is 100% Oct 31 01:01:47 ota3g1 Had[17275]: VCS ERROR V-16-1-10214 Concurrency Violation:CurrentCount increased above 1 for failover group sg_network Oct 31 01:06:50 ota3g1 Had[17275]: VCS ERROR V-16-1-10214 Concurrency Violation:CurrentCount increased above 1 for failover group sg_network Oct 31 01:11:52 ota3g1 Had[17275]: VCS ERROR V-16-1-10214 Concurrency Violation:CurrentCount increased above 1 for failover group sg_network Oct 31 01:12:10 ota3g1 kernel: lpfc 0000:29:00.1: 1:1305 Link Down Event x2 received Data: x2 x20 x80000 x0 x0 Oct 31 01:12:10 ota3g1 kernel: lpfc 0000:29:00.1: 1:1303 Link Up Event x3 received Data: x3 x1 x10 x1 x0 x0 0 Oct 31 01:12:12 ota3g1 kernel: lpfc 0000:29:00.1: 1:1305 Link Down Event x4 received Data: x4 x20 x80000 x0 x0 Oct 31 01:12:40 ota3g1 kernel: rport-8:0-0: blocked FC remote port time out: saving binding Oct 31 01:12:40 ota3g1 kernel: lpfc 0000:29:00.1: 1:(0):0203 Devloss timeout on WWPN 20:25:00:a0:b8:74:f5:65 NPort x0000e4 Data: x0 x7 x0 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 38617577 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 283532153 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 90825 Oct 31 01:12:40 ota3g1 kernel: Aborting journal on device dm-16. Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 868841 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: Aborting journal on device dm-10. Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 37759889 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 283349449 Oct 31 01:12:40 ota3g1 kernel: printk: 6 messages suppressed. Oct 31 01:12:40 ota3g1 kernel: Aborting journal on device dm-12. Oct 31 01:12:40 ota3g1 kernel: EXT3-fs error (device dm-12) in ext3_reserve_inode_write: Journal has aborted Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-16, logical block 1545 Oct 31 01:12:40 ota3g1 kernel: lost page write due to I/O error on dm-16 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 12745 Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-10, logical block 1545 Oct 31 01:12:40 ota3g1 kernel: EXT3-fs error (device dm-16) in ext3_reserve_inode_write: Journal has aborted Oct 31 01:12:40 ota3g1 kernel: lost page write due to I/O error on dm-10 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 37749121 Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-12, logical block 0 Oct 31 01:12:40 ota3g1 kernel: lost page write due to I/O error on dm-12 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: EXT3-fs error (device dm-12) in ext3_dirty_inode: Journal has aborted Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 37757897 Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-12, logical block 1097 Oct 31 01:12:40 ota3g1 kernel: lost page write due to I/O error on dm-12 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 283337089 Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-16, logical block 0 Oct 31 01:12:40 ota3g1 kernel: lost page write due to I/O error on dm-16 Oct 31 01:12:40 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:40 ota3g1 kernel: EXT3-fs error (device dm-16) in ext3_dirty_inode: Journal has aborted Oct 31 01:12:40 ota3g1 kernel: end_request: I/O error, dev sdi, sector 37749121 Oct 31 01:12:40 ota3g1 kernel: Buffer I/O error on device dm-12, logical block 0 Oct 31 01:12:41 ota3g1 kernel: lost page write due to I/O error on dm-12 Oct 31 01:12:41 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 Oct 31 01:12:41 ota3g1 kernel: end_request: I/O error, dev sdi, sector 283337089 Oct 31 01:12:41 ota3g1 kernel: Buffer I/O error on device dm-16, logical block 0 Oct 31 01:12:41 ota3g1 kernel: lost page write due to I/O error on dm-16 Oct 31 01:12:41 ota3g1 kernel: sd 8:0:0:4: SCSI error: return code = 0x00010000 df -h Filesystem Size Used Avail Use% Mounted on /dev/mapper/cciss-root 4.9G 730M 3.9G 16% / /dev/mapper/cciss-home 9.7G 1.2G 8.1G 13% /home /dev/mapper/cciss-var 9.7G 494M 8.8G 6% /var /dev/mapper/cciss-usr 15G 2.6G 12G 19% /usr /dev/mapper/cciss-tmp 3.9G 153M 3.6G 5% /tmp /dev/sda1 996M 43M 902M 5% /boot tmpfs 5.9G 0 5.9G 0% /dev/shm /dev/mapper/cciss-product 25G 16G 7.4G 68% /product /dev/mapper/cciss-opt 20G 4.5G 14G 25% /opt /dev/mapper/dg_db1-vol_db1_system 18G 2.2G 15G 14% /database/OTADB/sys /dev/mapper/dg_db1-vol_db1_undo 18G 5.8G 12G 35% /database/OTADB/undo /dev/mapper/dg_db1-vol_db1_redo 8.9G 4.3G 4.2G 51% /database/OTADB/redo /dev/mapper/dg_db1-vol_db1_sgbd 8.9G 654M 7.8G 8% /database/OTADB/admin /dev/mapper/dg_db1-vol_db1_arch 98G 24G 69G 26% /database/OTADB/arch /dev/mapper/dg_db1-vol_db1_indexes 240G 14G 214G 6% /database/OTADB/index /dev/mapper/dg_db1-vol_db1_data 275G 47G 215G 18% /database/OTADB/data /dev/mapper/dg_dbrman-vol_db_rman 8.9G 351M 8.1G 5% /database/RMAN /dev/mapper/dg_app1-vol_app1 151G 113G 31G 79% /files/ota /etc/fstab /dev/cciss/root / ext3 defaults 1 1 /dev/cciss/home /home ext3 defaults 1 2 /dev/cciss/var /var ext3 defaults 1 2 /dev/cciss/usr /usr ext3 defaults 1 2 /dev/cciss/tmp /tmp ext3 defaults 1 2 LABEL=/boot /boot ext3 defaults 1 2 tmpfs /dev/shm tmpfs defaults 0 0 devpts /dev/pts devpts gid=5,mode=620 0 0 sysfs /sys sysfs defaults 0 0 proc /proc proc defaults 0 0 /dev/cciss/swap swap swap defaults 0 0 /dev/cciss/product /product ext3 defaults 1 2 /dev/cciss/opt /opt ext3 defaults 1 2 /dev/dg_db1/vol_db1_system /database/OTADB/sys ext3 defaults 1 2 /dev/dg_db1/vol_db1_undo /database/OTADB/undo ext3 defaults 1 2 /dev/dg_db1/vol_db1_redo /database/OTADB/redo ext3 defaults 1 2 /dev/dg_db1/vol_db1_sgbd /database/OTADB/admin ext3 defaults 1 2 /dev/dg_db1/vol_db1_arch /database/OTADB/arch ext3 defaults 1 2 /dev/dg_db1/vol_db1_indexes /database/OTADB/index ext3 defaults 1 2 /dev/dg_db1/vol_db1_data /database/OTADB/data ext3 defaults 1 2 /dev/dg_dbrman/vol_db_rman /database/RMAN ext3 defaults 1 2 /dev/dg_app1/vol_app1 /files/ota ext3 defaults 1 2 Thanks for all the help.

    Read the article

  • Will this RAID5 setup work (3TB Seagate Barracudas + Adaptec RAID 6405)?

    - by Slayer537
    As the title states, will this RAID combo work, and if not what needs to be changed? Overall opinions would be most helpful. I currently run a small file server of about 5TB or so. I keep outgrowing my needs and need to build a RAID setup that will allow me to expand as needed. I am new to RAID setups, especially one of the scale I have currently planned out, but I have being doing some research for the past couple of weeks and have come up with a build. Ideally, I'd have the setup completely built, but I'd like to keep the total cost around $1k and can't afford to go above $1.5k, so unfortunately that's not an option. 2 of my current drives are WD Caviar Blacks 2TB; however, I have recently learned that due to the lack of TLER those drives are awful for any RAID setup other than 0 or 1. That being said, my third drive is a Seagate Barracuda 3TB (ST300DM001) and I have found a RAID controller that states it supports it, so I'd like to use this same type of drive, if possible. Have any of you had any experience using this drive or a similar one in a RAID5 configuration? The manufacturer states that it supports it, but knowing that it is not an enterprise drive, I am slightly concerned that it could drop out of the array. I would just go with enterprise drives, but those are about double in cost... Parts list: Storage rack: http://www.ebay.com/itm/SGI-3U-Media-Storage-Server-16-Hard-Drive-Bay-SATA-SAS-Expander-Omnistor-SE3016-/140735776937?pt=LH_DefaultDomain_0&hash=item20c48188a9 3 more HDs (for now..): http://www.amazon.com/Seagate-Barracuda-3-5-Inch-Internal-ST3000DM001/dp/B005T3GRLY/ref=dp_return_2?ie=UTF8&n=172282&s=electronics Adaptec RAID 6405: http://www.newegg.com/Product/Product.aspx?Item=N82E16816103224 here's a link to the compatibility sheet if that helps: http://download.adaptec.com/pdfs/compatibility_report/arc-sas_cr_03-27-12_series6.pdf SAS expander cable: http://www.pc-pitstop.com/sas_cables_adapters/8887-2M.asp My plan is to install the RAID card in my computer and then route the SAS cable to the rack. Setup a RAID5 on 3 drives, transfer my data over from my other drive, and then add that drive to the array. Eventually, I'd like to get a 2U unit and run the file server on that and move the RAID card over to there, but that will have to happen later on. Side note: The computer the card would be going into will be running Windows 7 Pro with 24GB of DDR3-1600 and an i7-930.

    Read the article

  • All Xen domU LVM volumes corrupt after reboot

    - by zcs
    I'm running a Debian Squeeze dom0, and after rebooting it all 7 of my domUs have data corruption. Each is setup as ext3 partition directly on a separate lvm2 volume. None of the lvm volumes will mount; all have bad superblocks. I've tried e2fsck with each superblock to no avail. What else can I try? Each domU has two LVM volumes connected to it, one for the disk and one for swap. The disk is mounted at root, formatted as a normal ext3 partition as a xen-blk device. The volumes are never mounted outside of the guest OS. I'm running Ubuntu 11.04 using the instructions here. I'm not sure that they didn't shutdown properly, all I know is they were corrupt after I issues a clean 'reboot' on the dom0. Here's a sample Xen config file; the rest are the same except for name, vcpus, memory, vif and disk. name = 'load1' vcpus = 2 memory = 512 vif = ['bridge=prbr0', 'bridge=eth0'] disk = ['phy:/dev/VolGroup00/load1-disk,xvda,w','phy:/dev/VolGroup00/load1-swap,xvdb,w'] #============================================================================ # Debian Installer specific variables def check_bool(name, value): value = str(value).lower() if value in ('t', 'tr', 'tru', 'true'): return True return False global var_check_with_default def var_check_with_default(default, var, val): if val: return val return default xm_vars.var('install', use='Install Debian, default: false', check=check_bool) xm_vars.var("install-method", use='Installation method to use "cdrom" or "network" (default: network)', check=lambda var, val: var_check_with_default('network', var, val)) # install-method == "network" xm_vars.var("install-mirror", use='Debian mirror to install from (default: http://archive.ubuntu.com/ubuntu)', check=lambda var, val: var_check_with_default('http://archive.ubuntu.com/ubuntu', var, val)) xm_vars.var("install-suite", use='Debian suite to install (default: natty)', check=lambda var, val: var_check_with_default('natty', var, val)) # install-method == "cdrom" xm_vars.var("install-media", use='Installation media to use (default: None)', check=lambda var, val: var_check_with_default(None, var, val)) xm_vars.var("install-cdrom-device", use='Installation media to use (default: xvdd)', check=lambda var, val: var_check_with_default('xvdd', var, val)) # Common options xm_vars.var("install-arch", use='Debian mirror to install from (default: amd64)', check=lambda var, val: var_check_with_default('amd64', var, val)) xm_vars.var("install-extra", use='Extra command line options (default: None)', check=lambda var, val: var_check_with_default(None, var, val)) xm_vars.var("install-installer", use='Debian installer to use (default: network uses install-mirror; cdrom uses /install.ARCH)', check=lambda var, val: var_check_with_default(None, var, val)) xm_vars.var("install-kernel", use='Debian installer kernel to use (default: uses install-installer)', check=lambda var, val: var_check_with_default(None, var, val)) xm_vars.var("install-ramdisk", use='Debian installer ramdisk to use (default: uses install-installer)', check=lambda var, val: var_check_with_default(None, var, val)) xm_vars.check() if not xm_vars.env.get('install'): bootloader="/usr/sbin/pygrub" elif xm_vars.env['install-method'] == "network": import os.path print "Install Mirror: %s" % xm_vars.env['install-mirror'] print "Install Suite: %s" % xm_vars.env['install-suite'] if xm_vars.env['install-installer']: installer = xm_vars.env['install-installer'] else: installer = xm_vars.env['install-mirror']+"/dists/"+xm_vars.env['install-suite'] + \ "/main/installer-"+xm_vars.env['install-arch']+"/current/images" print "Installer: %s" % installer print print "WARNING: Installer kernel and ramdisk are not authenticated." print if xm_vars.env.get('install-kernel'): kernelurl = xm_vars.env['install-kernel'] else: kernelurl = installer + "/netboot/xen/vmlinuz" if xm_vars.env.get('install-ramdisk'): ramdiskurl = xm_vars.env['install-ramdisk'] else: ramdiskurl = installer + "/netboot/xen/initrd.gz" import urllib class MyUrlOpener(urllib.FancyURLopener): def http_error_default(self, req, fp, code, msg, hdrs): raise IOError("%s %s" % (code, msg)) urlopener = MyUrlOpener() try: print "Fetching %s" % kernelurl kernel, _ = urlopener.retrieve(kernelurl) print "Fetching %s" % ramdiskurl ramdisk, _ = urlopener.retrieve(ramdiskurl) except IOError, _: raise elif xm_vars.env['install-method'] == "cdrom": arch_path = { 'i386': "/install.386", 'amd64': "/install.amd" } if xm_vars.env['install-media']: print "Install Media: %s" % xm_vars.env['install-media'] else: raise OptionError("No installation media given.") if xm_vars.env['install-installer']: installer = xm_vars.env['install-installer'] else: installer = arch_path[xm_vars.env['install-arch']] print "Installer: %s" % installer if xm_vars.env.get('install-kernel'): kernelpath = xm_vars.env['install-kernel'] else: kernelpath = installer + "/xen/vmlinuz" if xm_vars.env.get('install-ramdisk'): ramdiskpath = xm_vars.env['install-ramdisk'] else: ramdiskpath = installer + "/xen/initrd.gz" disk.insert(0, 'file:%s,%s:cdrom,r' % (xm_vars.env['install-media'], xm_vars.env['install-cdrom-device'])) bootloader="/usr/sbin/pygrub" bootargs="--kernel=%s --ramdisk=%s" % (kernelpath, ramdiskpath) print "From CD" else: print "WARNING: Unknown install-method: %s." % xm_vars.env['install-method'] if xm_vars.env.get('install'): # Figure out command line if xm_vars.env['install-extra']: extras=[xm_vars.env['install-extra']] else: extras=[] # Reboot will just restart the installer since this file is not # reparsed, so halt and restart that way. extras.append("debian-installer/exit/always_halt=true") extras.append("--") extras.append("quiet") console="hvc0" try: if len(vfb) >= 1: console="tty0" except NameError, e: pass extras.append("console="+ console) extra = str.join(" ", extras) print "command line is \"%s\"" % extra root There are two LVM logical volumes connected to each VM. Here's the fdisk -l output for the disk volume: Disk /dev/VolGroup00/VMNAME-disk: 8589 MB, 8589934592 bytes 255 heads, 63 sectors/track, 1044 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00029c01 Device Boot Start End Blocks Id System /dev/VolGroup00/VMNAME-disk1 1 1045 8386560 83 Linux And the swap volume: Disk /dev/VolGroup00/VMNAME-swap: 536 MB, 536870912 bytes 37 heads, 35 sectors/track, 809 cylinders Units = cylinders of 1295 * 512 = 663040 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x0004faae Device Boot Start End Blocks Id System /dev/VolGroup00/VMNAME-swap1 2 809 522240 82 Linux swap / Solaris Partition 1 has different physical/logical beginnings (non-Linux?): phys=(0, 32, 33) logical=(1, 21, 19) Partition 1 has different physical/logical endings: phys=(65, 36, 35) logical=(808, 4, 28)

    Read the article

  • How to setup RAM disk drive using python or WMI?

    - by Ming Xie
    Hi, The background of my question is associated with Tesseract, the free OCR engine (1985-1995 by HP, now hosting in Google). It specifically requires an input file and an output file; the argument only takes filename (not stream / binary string), so in order to use the wrapper API such as pytesser and / or python-tesser.py, the OCR temp files must be created. I, however, have a lot of images need to OCR; frequent disk write and remove is inevitable (and of course the performance hit). The only choice I could think about is changing the wrapper class and point the temp file to RAM disk, which bring this problem up. If you have better solution, please let me know. Thanks a lot. -M

    Read the article

  • C/C++/Assembly Programatically detect if hyper-threading is active on Windows, Mac and Linux

    - by HTASSCPP
    I can already correctly detect the number of logical processors correctly on all three of these platforms. To be able to detect the number of physical processors/cores correctly I'll have to detect if hyperthreading is supported AND active (or enabled if you prefer) and if so divide the number of logical processors by 2 to determine the number of physical processors. Perphaps I should provide an example: A quad core Intel CPU's with hyperthreading enabled has 4 physical cores, yet 8 logical processors (hyperthreading creates 4 more logical processors). So my current function would detect 8 instead of the desired 4. My question therefore is if there is a way to detect whether hyperthreading is supported AND ENABLED?

    Read the article

  • Did anyone give these smart pointers (auto_any, scoped_any, shared_any) a test drive?

    - by Johann Gerell
    I'm investigating smart pointers with "shared" functionality for Windows CE and Mobile, where the VS 2008 tr1 std::shared_ptr cannot be used (due to linkage to a v.9 dll not present on CE, obviously, if I understand it correctly). There's a semi-old MSDN Magazine article with sources from a Microsoftie (Eric Niebler): Achieve More Reliable Resource Management with Our Custom C++ Classes. The reasoning, design and implementation of his shared_any looks solid, but I'm wondering if anyone ever actually tested the lot on any platform (not necessarily WinCe/WM)?

    Read the article

  • Best RAID setup for multimedia fileserver?

    - by Mr. Schwabe
    I'm building a fileserver for my small office. We do film and multimedia design. Only 3 clients connected. The server is primarily for local access to graphic assets and video files. I'm looking for advice on hardware and software required. Particularly for the RAID. I have the following objectives: A) merged capacity I'd like all other systems to access the data as a single mapped network drive that has an initial capacity of 10 TB. So perhaps 5x 2TB drives (plus mirror drives for redundancy). B) easy way to increase capacity Thinking long term, I'd like to 'easily' add more drives to the array for a potential two or three fold increase in capacity. So theoretically it could get upto a 30 TB raid array consisting of maybe 15x 2 TB drives of capacity (plus mirror drives for redundancy). C) maximum fault tolerance I want at least 1 mirror drive per capacity drive (in laymen's terms). So if I start with 10 TB / 5x 2TB of capacity, I suppose I would need another another 5x 2TB drives to be mirrors. So 10 drives total. But I'd also like potential for even more redundancy; with upto 2 additional mirrors per 'capacity drive' (and to be able to add them to the array anytime with ease). D) easy way to monitor drive health I'd like an intuitive interface for managing the raid and monitoring drive health The other systems accessing this network drive will be running Windows, but also the odd Ubuntu and MacOS system as well. Are these objectives attainable? What type of RAID setup do you recommend? What hardware will be required? Also what OS do you think this system should be running? Does it really matter? I'm no network admin - just a long time Windoze user, without much Linux experience. That said, I'm not opposed to a Linux solution if it's easy enough and more practical than a Windows OS for this server. Or maybe something such as Openfiler. Budget should hit the sweet spot for value and performance (hence my preference to use 2TB drives). The biggest focus is storage; aside from that the system just needs to keep the drives running optimally with perhaps 2 or 3 clients accessing / writing files at any given time. The hardware quote would start with something like 10x 2TB WD Caviar Blacks; about $1900 for the storage + $x for remaining parts. http://ncix.com/products/index.php?sku=42775&vpn=WD2001FASS&manufacture=Western%20Digital%20WD Your advice is appreciated, thanks!

    Read the article

  • Java class Class<T> and static method Class.forName() drive me crazy.

    - by matt
    Hi, this code doesn't compile. i'm wandering what i am doing wrong: private static Importable getRightInstance(String s) throws Exception { Class<Importable> c = Class.forName(s); Importable i = c.newInstance(); return i; } where Importable is an interface and the string s is the name of an implementing class. The compiler says: ./Importer.java:33: incompatible types found : java.lang.Class<capture#964 of ?> required: java.lang.Class<Importable> Class<Importable> c = Class.forName(format(s)); thanks for any help!

    Read the article

  • Batch file script for attrib

    - by Deven
    I want to create a batch file for run attrib script for pen drive. But problem is pen drive changes. batch file that 1st ask to write drive letter Then run attrib script for that drive. (my pendrive gets virus from class that i want to clear at home by aplying attrib script below everyday attrib -r -a -s -h /s /d

    Read the article

  • Sharing files between multiple sites using only desktop software

    - by perlyking
    Our organisation has three sites; a head office, where the master copies of company files are stored, plus two branch offices using only workstations and a NAS or two. Currently we're talking about <10GB. At the main office, we have no admin access to the file server, as this is entirely controlled by the larger institution where we are located. For the same reason, we have no VPN remote access to this network. Instead, we simply have access to a network share using over a Novell LAN. Question: how can we share files between offices in way that minimises latency, i.e. that gives us a mirror of the main network share at each site? (There is little likelihood of concurrent editing, and we can live with the odd file conflict now and again). Up to now branch office staff have had to use GotoMyPC-type solutions to remotely access files held at the main office. Or email. I was hoping to use Google Drive on a dedicated workstation at each office to sync the contents of the network share (head office) or NAS (branch offices) via the cloud, but at my last attempt (29 Jun '12), the Google Drive installer would not allow me to designate the remote network share as the "target" folder. (I chose Google Drive over Drobbox et al. as we already use GMail for corporate mail) The next idea was to use a designated workstation at head office to mirror the network share to a local drive, then use Google Drive to push that to the cloud. This seems a step too far. Nor do I have any good ideas about how to achieve this network/local mirroring, as we can't, for example, install the rsync daemon on the server. I do not want to use Google Drive locally on each workstation as this will inconvenience users, and more importantly, move files off the backed-up, well-maintained (UPS, RAID etc) network share at head office. Our budget is only in the £100's. Should we perhaps just ditch the head office server and use something like JungleDisk? At least this presents the user with what appears to be a mapped drive.

    Read the article

  • Reverse Engineer a web page

    - by Phil
    Hi, I wish to reverse engineer any web-page into a logical representation of the page. For example, if a web page has a menu, then I want a logical menu structure perhaps in XML. If the webpage has an article, I want a article XML node, if it has a title for the article I want a title XML node. Basically, I want the logical form of the web-page without any of the user interface. This logical model could either be objects in code or XML it doesn't matter, the important part is that it has identified what everything on the page means.

    Read the article

  • API to calculate drive distance between 2 US street addresses?

    - by ggonsalv
    Seems simple but users have no internet access. The application will be hosted internally on as Intranet site. The application will be able to make webservice calls to the internet. I tested and tried Mapquest. However all the other providers seems to assume the users are able to access the internet so their API's are javascript based with src tags pointing to internet URL's Any ideas?

    Read the article

  • Class<T> and static method Class.forName() drive me crazy.

    - by matt
    Hi, this code doesn't compile. I'm wondering what I am doing wrong: private static Importable getRightInstance(String s) throws Exception { Class<Importable> c = Class.forName(s); Importable i = c.newInstance(); return i; } where Importable is an interface and the string s is the name of an implementing class. The compiler says: ./Importer.java:33: incompatible types found : java.lang.Class<capture#964 of ?> required: java.lang.Class<Importable> Class<Importable> c = Class.forName(format(s)); thanks for any help! All the solutions Class<? extends Importable> c = Class.forName(s).asSubclass(Importable.class); and Class<? extends Importable> c = (Class<? extends Importable>) Class.forName(s); and Class<?> c = Class.forName(format(s)); Importable i = (Importable)c.newInstance(); give this error: Exception in thread "main" java.lang.IncompatibleClassChangeError: class C1 has interface Importable as super class where C1 is effectively a class implementing Importable, one of those i want to cast to Importable.

    Read the article

  • What method do you use to identify the Aggregate Roots in Domain Drive Design?

    - by Robert
    When applying Domain Driven Design to a project, how do you identify the Aggregate Roots? For example, in a standard E-Commerce website, you might say that the Order is one, and the User is the other. But what if your Users belong to a Company? Does that make your Company the aggregate root? I'm interested in hearing people's approaches to working out the Aggregate roots, and how to identify poorly chosen aggregate roots.

    Read the article

  • Path with no slash after drive letter and colon - what does it point to?

    - by ya23
    I have mistyped a path and instead of c:\foo.txt wrote c:foo.txt. I expected it to either fail or to resolve to c:\foo.txt, but instead it seems to be resolved to foo.txt in a current user's home folder. Powershell returns: PS C:\> [System.IO.Path]::GetFullPath("c:\foo.txt") c:\foo.txt PS C:\> [System.IO.Path]::GetFullPath("c:foo.txt") C:\Users\Administrator\foo.txt PS C:\> [System.IO.Path]::GetFullPath("g:foo.txt") G:\foo.txt Running explorer.exe from commandline and passing it any of the above results in C:\Users\Administrator\Documents to be opened. I haven't found any documentation of that and I'm utterly confused, please explain the behaviour.

    Read the article

  • Need data on disk drive management by OS: getting base I/O unit size, “sync” option, Direct Memory A

    - by Richard T
    Hello All, I want to ensure I have done all I can to configure a system's disks for serious database use. The three areas I know of (any others?) to be concerned about are: I/O size: the database engine and disk's native size should either match, or the database's native I/O size should be a multiple of the disk's native I/O size. Disks that are capable of Direct Memory Access (eg. IDE) should be configured for it. When a disk says it has written data persistently, it must be so! No keeping it in cache and lying about it. I have been looking for information on how to ensure these are so for CENTOS and Ubuntu, but can't seem to find anything at all! I want to be able to check these things and change them if needed. Any and all input appreciated.

    Read the article

  • moving raid 10 to another identical server both on Smart Array 6i controllers

    - by SalimQrdl
    I have dead HP DL 380G4 with RAID 1+0 with 1 logical volume from 4x72GB drives on built-in Smart Array 6i 128Mb BBWC. It was shut down properly. It seems it was usual death for Proliant with ILO led 2,3,8 lighting. I want to move array to another identical server with same raid firmware level. What is the best strategy?: I have RAID 1+0 on bay 0 bay 1 bay 2 bay 3 As I understand bay0+bay1 are in RAID 1 , bay2+bay3 are in RAID 1, and both RAID 1 pairs are in RAID 0. So should I : Clear RAID config on new server, insert bay 0, bay 2 and power-on or Create RAID 1+0 with 1 logical volume from clear HDDs , and then poweroff ,remove HDDs and insert 2 HDDs(bay 0, bay 2) from old RAID 1+0. then power-on. (each hdd has its raid position info stored but may be could work on same config) According to documentation for Smart Array 6i it could be possible to migrate. however one requirement point is unclear for me Before you move drives, the following conditions must be met: • The array is in its original configuration. " What is orginal and non-original config for RAID 1+0? Another point "If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time." I want to move one hdd from each RAID 1 pair. to have mirrors untouched just in case. Do they mean to move all 4 simultaniously? Smart Array 6i User Guide: Moving Drives and Arrays You can move drives to other ID positionson the same array controller. You can also move a complete arrayfrom one controller to another, even if the controllers are on different servers. Before you move drives, the following conditions must be met: • If moving thedrives to a different server, the new server must have enough empty bays to accommodate all the drives simultaneously. • The move will not result in more than 14 physical drives per controller channel. • No controller will be configured with more than 32 logical volumes. • The array has no failed or missing drives. • The array is in its original configuration. • The controller is not reading from or writing to any of the spare drives in the array. • The controller is not running capacity expansion, capacity extension, or RAID or stripe size migration. • The controller is using the latestfirmware version (recommended). If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time. • In most cases, a moved array (and the logical drives that it contains) can still undergo arraycapacity expansion, logical drive capacity extension, or migration of RAID level orstripe size. When all the conditions have been met: Back up all data before removing any drives or changing configuration. This step is requiredif you are moving data-containing drives from a controller that does not have a battery-backed cache. Power down the system. If you are moving an array from a controller that contains a RAID ADG logical volume to a controller that does not support RAID ADG: Move the drives. Power up the system. If a 1724 POST message is displayed, drive positions were changed successfully and the configuration was updated. If a 1785 (NotConfigured)POST message is displayed: a. Power down the system immediately to prevent data loss. b. Return the drives to their original locations. c. Restore the data from backup, if necessary. Check the new drive configuration byrunning ORCA or ACU ("Configuring an Array" on page 9).

    Read the article

  • Windows 7 inbuilt and 3rd party (de)fragmentation related queries

    - by Karan
    I have a pretty good idea of how files end up getting fragmented. That said, I just copied ~3,200 files of varying sizes (from a few KB to ~20GB) from an external USB HDD to an internal, freshly formatted (under Windows 7 x64), NTFS, 2TB, 5400RPM, WD, SATA, non-system (i.e. secondary) drive, filling it up 57%. Since it should have been very much possible for each file to have been stored in one contiguous block, I expected the drive to be fragmented not more than 1-2% at most after this rather lengthy exercise (unfortunately this older machine doesn't support USB 3.0). Windows 7's inbuilt defrag utility told me after a quick analysis that the drive was fragmented only 1% or so, which dovetailed neatly with my expectations. However, just out of curiosity I downloaded and ran the latest portable x64 version of Piriform's Defraggler, and was shocked to see the drive being reported as being ~85% fragmented! The portable version of Auslogics Disk Defrag also agreed with Defraggler, and both clearly expected to grind away for ~10 hours to completely defragment the drive. 1) How in blazes could the inbuilt and 3rd party defrag utils disagree so badly? I mean, 10-20% variance is probably understandable, but 1% and 85% are miles apart! This Engineering Windows 7 blog post states: In Windows XP, any file that is split into more than one piece is considered fragmented. Not so in Windows Vista if the fragments are large enough – the defragmentation algorithm was changed (from Windows XP) to ignore pieces of a file that are larger than 64MB. As a result, defrag in XP and defrag in Vista will report different amounts of fragmentation on a volume. ... [Please read the entire post so the quote is not taken out of context.] Could it simply be that the 3rd party defrag utils ignore this post-XP change and continue to use analysis algos similar to those XP used? 2) Assuming that the 3rd party utils aren't lying about the real extent of fragmentation (which Windows is downplaying post-XP), how could the files have even got fragmented so badly given they were just copied over afresh to an empty drive? 3) If vastly differing analysis algos explain the yawning gap, which do I believe? I'm no defrag fanatic for sure, but 85% is enough to make me seriously consider spending 10 hours defragging this drive. On the other hand, 1% reported by Windows' own defragger clearly implies that there is no cause for concern and defragging would actually have negative consequences (as per the post). Is Windows' assumption valid and should I just let it be, or will there be any noticeable performance gains after running one of the 3rd party utils for 10 hours straight? 4) I see that out of the box Windows 7 defrag is scheduled to run weekly. Does anyone know whether it defrags every single time, or only if its analysis reveals a fragmentation percentage over a set threshold? If the latter, what is this threshold and can it be changed, maybe via a Registry edit? Thanks for reading through (my first query on this wonderful site!) and for any helpful replies. Also, if you're answering question #3, please keep in mind that any speed increases post defragging with 3rd party utils vis-à-vis Windows' inbuilt program should not include pre-Vista (preferably pre-Win7) examples. Further, examples of programs that made your system boot faster won't help in this case, since this is a non-system drive (although one that'll still be used daily).

    Read the article

< Previous Page | 165 166 167 168 169 170 171 172 173 174 175 176  | Next Page >