Search Results

Search found 9608 results on 385 pages for 'flash drives'.

Page 170/385 | < Previous Page | 166 167 168 169 170 171 172 173 174 175 176 177  | Next Page >

  • Optimizing Disk I/O & RAID on Windows SQL Server 2005

    - by David
    I've been monitoring our SQL server for a while, and have noticed that I/O hits 100% every so often using Task Manager and Perfmon. I have normally been able to correlate this spike with SUSPENDED processes in SQL Server Management when I execute "exec sp_who2". The RAID controller is controlled by LSI MegaRAID Storage Manager. We have the following setup: System Drive (Windows) on RAID 1 with two 280GB drives SQL is on a RAID 10 (2 mirroed drives of 280GB in two different spans) This is a database that is hammered during the day, but is pretty inactive at night. The DB size is currently about 13GB, and is used by approximately 200 (and growing) users a day. I have a couple of ideas I'm toying around with: Checking for Indexes & reindexing some tables Adding an additional RAID 1 (with 2 new, smaller, HDs) and moving the SQL's Log Data File (LDF) onto the new RAID. For #2, my question is this: Would we really be increasing disk performance (IO) by moving data off of the RAID 10 onto a RAID 1? RAID 10 obviously has better performance than RAID 1. Furthermore, SQL must write to the transaction logs before writing to the database. But on the flip side, we'll be reducing both the size of the disks as well as the amount of data written to the RAID 10, which is where all of the "meat" is - thereby increasing that RAID's performance for read requests. Is there any way to find out what our current limiting factor is? (The drives vs. the RAID Controller)? If the limiting factor is the drives, then maybe adding the additional RAID 1 makes sense. But if the limiting factor is the Controller itself, then I think we're approaching this thing wrong. Finally, are we just wasting our time? Should we instead be focusing our efforts towards #1 (reindexing tables, reducing network latency where possible, etc...)?

    Read the article

  • How to create partition when growing raid5 with mdadm.

    - by hometoast
    I have 4 drives, 2x640GB, and 2x1TB drives. My array is made up of the four 640GB partitions and the beginning of each drive. I want to replace both 640GB with 1TB drives. I understand I need to 1) fail a disk 2) replace with new 3) partition 4) add disk to array My question is, when I create the new partition on the new 1TB drive, do I create a 1TB "Raid Auto Detect" partition? Or do I create another 640GB partition and grow it later? Or perhaps the same question could be worded: after I replace the drives how to I grow the 640GB raid partitions to fill the rest of the 1TB drive? fdisk info: Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xe3d0900f Device Boot Start End Blocks Id System /dev/sdb1 1 77825 625129281 fd Linux raid autodetect /dev/sdb2 77826 121601 351630720 83 Linux Disk /dev/sdc: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xc0b23adf Device Boot Start End Blocks Id System /dev/sdc1 1 77825 625129281 fd Linux raid autodetect /dev/sdc2 77826 121601 351630720 83 Linux Disk /dev/sdd: 640.1 GB, 640135028736 bytes 255 heads, 63 sectors/track, 77825 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x582c8b94 Device Boot Start End Blocks Id System /dev/sdd1 1 77825 625129281 fd Linux raid autodetect Disk /dev/sde: 640.1 GB, 640135028736 bytes 255 heads, 63 sectors/track, 77825 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xbc33313a Device Boot Start End Blocks Id System /dev/sde1 1 77825 625129281 fd Linux raid autodetect Disk /dev/md0: 1920.4 GB, 1920396951552 bytes 2 heads, 4 sectors/track, 468846912 cylinders Units = cylinders of 8 * 512 = 4096 bytes Disk identifier: 0x00000000

    Read the article

  • Defrag starting when not scheduled. What is triggering the defrag

    - by leroyclark
    I have a fileserver that is starting a defrag around 2:00 PM everyday. This is killing performance as it runs for ours becuase this is a file server and has multiple drives. All scheduled tasks regarding defrag have been disabled. I have verified that it is accessing the data drives(using SysInternals tools). The reason I might have though otherwise was the event log has multiple entries regarding defragging a db file related to shadow copies. Oh yes these drives take shadow copy snapshots multiple times per day but the times of them don't coincide with the defrag task. There is nothing in the event logs regarding defrag except those noted above in relation to shadow copies. I'm out of ideas looking for what is starting these jobs. One possiblility is that the drives are not being defgramented, but being analyized to determine if they need to be defragmented. I manually ran an analysis and the cpu usage(by dfrgntfs.exe) seems to be similar to what I'm seeing everday while the defrag process is running. However I've found no setting that schedules this analysis.

    Read the article

  • Dell OpenManage On Ubuntu Server 12.04 Cannot Log In

    - by Austin
    I have a Dell Poweredge 2950 with 2X130GB and 2X2TB drives. I need to set them up in a RAID 1 array so that the 130GB Drives are mirrored and host the OS, while the 2TB drives are mirrored and are the content drives. So I go from 4 disks, down to two, one 130GB and one 2TB. I can do that in the BIOS RAID utility no problem. But I need to be able to manage the RAID arrays and be able to expand them WITHOUT shutting down the server. Now, to my understanding, openmanage will allow me to do that AND it runs on ubuntu. So I go and set it up and try to log into the web interface at and it will not let me log in. I have followed dell's guide to set up openmanage, even added the usernames to the files and permissions and such, however, cannot get it to let me log in or anything. I have reinstalled Openmanage several times, even reinstalled the OS three times, and nothing works. Google does not help either. It simply says login failed after hitting submit. Please Help

    Read the article

  • Are there any disadvantages of having a "free fall sensor" on a hard disk drive?

    - by therobyouknow
    This is a general question that came out of a specific comparison between the Western Digital Scorpio WD3200BEKT and Western Digital Scorpio WD3200BJKT (which is the same as the former but with a free fall sensor.) Note: I'm not asking for a review or appraisal of these specific drives, as the general question does apply on other brands as well. Though your input would help my decision. To break down the general question in order to answer it, I would be looking for comments on things like: if it's necessary to have differing physical dimensions between free fall sensor drives and those without, e.g. does it make it any thicker, and therefore reduce the systems where it can be installed - particularly smaller laptops? does it actually make the system less reliable - because of false alarms whereby the drive thought the laptop was falling but it wasn't? I suppose that the fact that a manufacturer produces both drives with and without free fall sensors says something about possible disadvantages. Or it could be standard marketing techniques where by making drives with and without results in larger sales volume than just those with the feature alone.

    Read the article

  • External SATA drive does not work without the optional USB cable *also* connected

    - by Software Monkey
    I have Vantec NST-260SU external eSATA/USB drive enclosure (which came with an optional separate power supply) connected to a relatively new Windows 7 computer. The drive should work as a SATA drive with either the separate power supply or using a USB cable solely for power. I would prefer to use the external power supply because I have used all my rear USB ports. Now, if I connect both the eSATA and USB cable, then: The drive shows in the BIOS list of AHCI drives (and not in the list of attached USB devices). Everything I can see about it in Computer Management seems to show it as a SATA driver (for example, it shows as "Location 0 (Channel 5, Target 0, Lun 0)" like my other SATA drives (and not "on USB Mass Storage Device" like my USB flash-drives). It seems very fast, very much faster than my USB flash drives. However, if I disconnect the USB cable and attach the power adapter instead, the drive does not show in the BIOS list and cannot be seen by Windows. The power LED on the enclosure is lit, and the drive enclosure becomes warm after running for a bit, so I am sure it is receiving power. Does anyone know if this device requires both the USB and eSATA cable, and if so, why? Or is there possibly something I need to do to reset the enclosure to not need the USB - the install instructions are pretty clear that you must connect the SATA cable before connecting the USB cable in order for the drive to function as SATA, which I am sure I did. PS: I have reviewed the small manual which came with it, which has not been of help.

    Read the article

  • Network connection keeps dropping - bad hardware?

    - by Bill Sambrone
    Hello all, I've into a bit of a wall with a client of mine. In an office of 20 people, he is the only one who experiences broken connections to his mapped network drives. I have everyone set up with about 6 mapped drives, all pointing to the same server (no DFS), and everyone else can access them lightning fast. The environment consists of a mix of Windows 7 and XP machines, all 32-bit. The server holding the data everyone is mapping to is running on Server 2008 R2, and is a domain controller. We recently swapped out their old 10/100 switch for a shiny new Dell PowerConnect gigabit switch. We have also replaced an old dying Sonicwall with a shiny new one. Everything is running on an ESX host except for the DC, where everyone is getting data from. In my client's office, we have done the following: Swapped out his computer (Win7 and XP box) Swapped out the desktop switch in his office Removed the desktop switch in his office Changed out the network cable going to the wall Ran 'net config server /autodisconnect:-1' on the server Disabled remote differential compression on his current Win7 box When we swapped out his network cable, everything seemed fine for about 4 days. Normally I would get a phone call a couple times per day letting me know that Outlook has crashed (there is a 9GB PST living on the server he is always connected to), or that his software he is running from his L drive has crashed. I almost thought I had this solved, but after we rebooted the DC the other night he all of a sudden couldn't stay connected to his mapped network drives for more than 10 minutes. When I ran 'net use' from the command prompt, it listed all the network drives where were randomly in a state of 'OK', 'Disconnected', or 'Reconnecting'. What else should I try? Maybe there is bad wiring in the wall, patch panel, or a bad port in the new switch I have in the server room?

    Read the article

  • External HDD incorrectly detected as internal - how change to enable hot swap/eject?

    - by Sam
    Hi All, I have win 7 x64 Home Prem. The HDD is a seagate barracuda, 7200.7 ST3120827AS. 3.5", Serial: 3ms006n6, Firmware: 3.42 (no further updates) NexStar CX External case (drivers installed). I have three drives: WD320 with OS installed WD750 data storage (internal) seagate 120 (external) - connected via esata board connected to sata on motherboard (MSI p43 neo) Tried uninstalling HDD in device manager to no effect. Also the internal WD750 is detected as an external drive and win taskbar icon allows for it to be ejected (unlike the seagate). All drives are configured - Online, Simple, Basic, NTFS, Active, Primary Partition (except c drive). The seagate was previously used as a primary disk with XP operating system so I deleted the volume and created/reformatted (not quick). HDD is no longer "Active". But did not fix problem. Background Originally, I installed win 7 with the bios set to IDE and forgot to install the chipset drivers. Then I changed win 7 to install the AHCI drivers, changed the bios to AHCI and rebooted. Win 7 loaded drivers but WD HDD gave problems/crashed. I installed chipset drivers and latest intell storage matrix software thingie (in safe mode). Everything worked fine after that except for the problem of not corrrectly detecting the external drive] I have noticed that under the driver properties (and similarly in the registry) the two drives are configured differently (e.g. in driver details property capabilities for the WD the value is set to 0000006, CM_DEVCAP_REMOVABLE & EJECTSUPPORTED - whereas the seagate shows 0000080 & CM_DEVCAP_SURPRISEREMOVALOK). Any easy way to configure things? I tried physically swapping the sata connections on the mainboard without success So far I have found that a solution to my problem might be to perform some reg changes: http://superuser.com/questions/12955/how-do-i-remove-the-option-to-eject-sata-drives-from-the-windows-7-tray-icon

    Read the article

  • h264 inside FLV container vs. MP4 container?

    - by Gotys
    I am developing a tube site, and currently having issues with h264 format . By looking at youtube, I noticed they are putting their hi-def videos into mp4 container, so logically I did the same. Next, I installed mod_h264_streaming for lighttpd to make streaming and timeline-scrubbing work. Problem is, that large files (500mb+ at somewhat high resolution) take for EVER to even start buffering ( I read the flowplayer or other flash players need to download metadata first) . I moved the xmov atom to the front of the file with MP4Box (i tried qt-quickstart too) , and the problem didn't go away. Next I read online I need to interleave audio tracks, so I did that too. No change in slowness. So I tried putting the same exact h264 movie into an FLV container, and the playback buffering starts almost instantly - no slowness. So what am I missing here? Why would I choose MP4 container with mod_264_streaming module , which seems super-slow over a regular FLV container with lighttpd's built-in mod_flv_streaming ? Obviously many websites pick mp4 container , but I fail to understand why ? And as a side question - I tried using HTML5's VIDEO tag to try the same h264 MP4 movie, and the scrubbing is LIGHTING FAST! I looked into lighttpd's log file, and i noticed taht Flash Players append video.mp4?start=234 each time timeline is scrubbed, wheres HTML5's video tag does no such thing . Is this some sort of limitations of Flash ? Why Can't flash streaming be same fast as HTML5 streaming? Thanks to ALL who can help. I very much appreciate this community.

    Read the article

  • External HDD incorrectly detected as internal - how change to enable hot swap/eject?

    - by Sam
    I have win 7 x64 Home Prem. The HDD is a seagate barracuda, 7200.7 ST3120827AS. 3.5", Serial: 3ms006n6, Firmware: 3.42 (no further updates) NexStar CX External case (drivers installed). I have three drives: WD320 with OS installed WD750 data storage (internal) seagate 120 (external) - connected via esata board connected to sata on motherboard (MSI p43 neo) Tried uninstalling HDD in device manager to no effect. Also the internal WD750 is detected as an external drive and win taskbar icon allows for it to be ejected (unlike the seagate). All drives are configured - Online, Simple, Basic, NTFS, Active, Primary Partition (except c drive). The seagate was previously used as a primary disk with XP operating system so I deleted the volume and created/reformatted (not quick). HDD is no longer "Active". But did not fix problem. Background Originally, I installed win 7 with the bios set to IDE and forgot to install the chipset drivers. Then I changed win 7 to install the AHCI drivers, changed the bios to AHCI and rebooted. Win 7 loaded drivers but WD HDD gave problems/crashed. I installed chipset drivers and latest intell storage matrix software thingie (in safe mode). Everything worked fine after that except for the problem of not corrrectly detecting the external drive] I have noticed that under the driver properties (and similarly in the registry) the two drives are configured differently (e.g. in driver details property capabilities for the WD the value is set to 0000006, CM_DEVCAP_REMOVABLE & EJECTSUPPORTED - whereas the seagate shows 0000080 & CM_DEVCAP_SURPRISEREMOVALOK). Any easy way to configure things? I tried physically swapping the sata connections on the mainboard without success So far I have found that a solution to my problem might be to perform some reg changes: How do I remove the option to eject SATA drives from the Windows 7 tray icon?

    Read the article

  • Reusing slot numbers in Linux software RAID arrays

    - by thkala
    When a hard disk drive in one of my Linux machines failed, I took the opportunity to migrate from RAID5 to a 6-disk software RAID6 array. At the time of the migration I did not have all 6 drives - more specifically the fourth and fifth (slots 3 and 4) drives were already in use in the originating array, so I created the RAID6 array with a couple of missing devices. I now need to add those drives in those empty slots. Using mdadm --add does result in a proper RAID6 configuration, with one glitch - the new drives are placed in new slots, which results in this /proc/mdstat snippet: ... md0 : active raid6 sde1[7] sdd1[6] sda1[0] sdf1[5] sdc1[2] sdb1[1] 25185536 blocks super 1.0 level 6, 64k chunk, algorithm 2 [6/6] [UUUUUU] ... mdadm -E verifies that the actual slot numbers in the device superblocks are correct, yet the numbers shown in /proc/mdstat are still weird. I would like to fix this glitch, both to satisfy my inner perfectionist and to avoid any potential sources of future confusion in a crisis. Is there a way to specify which slot a new device should occupy in a RAID array? UPDATE: I have verified that the slot number persists in the component device superblock. For the version 1.0 superblocks that I am using that would be the dev_number field as defined in include/linux/raid/md_p.h of the Linux kernel source. I am now considering direct modification of said field to change the slot number - I don't suppose there is some standard way to manipulate the RAID superblock?

    Read the article

  • Slow, choppy video playback with nVidia 8600GT

    - by user5351
    I have an nVidia 8600GT card (made by EVGA) on a machine with Windows Vista (AMD Athlon X2 processors) and four gigs of ram. It runs pretty good, but I have had some slow/choppy/stuterring video playback issues whenever watching flash videos on Youtube or other sites. The problem is there with both Firefox and IE flash videos, but is maybe worse with Firefox. I also tried Linux with nVidia's binary drivers and it was about the same. I downloaded EVGA precision which allows me to control stuff like the fan and clock speed. The card's temp (in both Vista and Linux) is usually at 66C when idle (not playing a game or watching anything). It goes up a little when watching a video (maybe 68-72C). Any ideas on how to fix this? UPDATE: The issues are both with full screen and embedded flash videos. I have Flash 10.0.32.18 (always make sure I use most recent for security), and the CPU is an AMD Athlon 64 X2 Dual Core Processor 4000+ at 2.11 GHZ. The current GPU driver installed is the most recent GeForce one from last July.

    Read the article

  • IDE compatability with SATA image

    - by Ormis
    We had an old CNC machine's hard-drive fail recently. The hard-drive is an old 1275MB IDE (Seagate) and there were defiantly bad sectors on it. I was able to image the contents of the drive onto a drive in my computer before it became completely unusable (I used DD, replacing all bad sectors w/ 0s). After running a couple chdsks, the SATA drive will boot off of the image. This is great, but there's one problem. The CNC machine old and requires IDE, I've attempted to copy the currently booting image off of the SATA drive and onto IDE drives numerous times in numerous ways and every time I do so the machines return that a boot device cannot be found. Some other information: The file system is fat32, running windows 98 The SATA drive is an 80gb drive I have tried copying the image to three 20gb and two 80gb IDE drives I have checked the jumper on the back of the IDE drives when using them If anyone has any ideas, questions, suggestions, etc. please let me know. P.S. I would just put a fresh install of win98 on the machine if i had the installation media (so that's out of the question). And if it comes to it, this is my last week working here, so I'll leave that to my co-worker. EDIT: Also, I have tried using Clonezilla as well as straight up DD to copy the image to the IDE drives.

    Read the article

  • Choice of filesystem for GNU/Linux on an SD card

    - by gspr
    Hi. I have am embedded ARM-based system running on an SD card. It's currently Debian GNU/Linux using ext3 as filesystem. As I'm about to reinstall the system, I started wondering about changing to a more flash-friendly filesystem. I've heard about JFFS2, YAFFS2 and LogFS, and they all seem suited to the job. Which one would you recommend? Also, I've heard there have been a lot of ext4 improvements to better suit SSD disks; am I to interpret that as running ext4 should be just fine? What do I need to think especially about in that case? I guess the usage of the system is important. But for the sake of generality, imagine it'll do standard desktop stuff (even though it is infact a small ARM-based system). Thanks for any replies. Edit: Wikipedia tells me (in a "citation needed" statement) that Removable flash memory cards and USB flash drives have built-in controllers to perform wear leveling and error correction so use of a specific flash file system does not add any benefit. Thus, I'm leaning towards sticking with an ext filesystem.

    Read the article

  • Problem with setting up RAID 5 on FreeNAS

    - by Benjy23
    I've been running FreeNAS for a while now. Hardware is 1.8 GHz Celeron, RAM 1 GB. SATA card is Via - I am not sure about the model. It's 2 ports and I have 6 x 1.5 TB hard drives. All ran OK while running on 1.5 TB, no RAID. I'm now trying to create a RAID 5 with my 6 hard drives. Software RAID. Is it normal for it to take roughly up to 2 weeks just to build the RAID? Sorry, I'm very new to implementing RAID and googling doesn't tell much other than it takes a long time. Also the RAID building process seems to fail many times. Going to degraded. I suspect it's because 4 of my hard drives are connected to my motherboard and the other 2 are connected to my SATA card. What's your take? I'm considering 2 options now. Either get a 8 port SATA card and attach all the hard drives to it. Or get a RAID controller 8 portcard which is probably going to be more pricey. Also how do you access hardware RAID through FreeNAS? I like how FreeNAS emails you should your harddrive fails. Can this be done as well with hardware RAID?

    Read the article

  • Can I have a single solid state drive and a RAID array on the same machine? [closed]

    - by jaminto
    Hi- To summarize, i'm looking to use a single solid state drive as my primary drive, and two conventional sata drives in a RAID 1 configuration for data. I am trying to install 64-bit Windows 7 onto this configuration. Is this possible? Here are the details: I built a desktop that has been running 64-bit Vista on two 500Gb in a RAID 1 array for a few years. I just purchased an Intel X25-M 80Gb Sata Solid-State Drive, and was planning on using this a my primary drive, and keeping the RAID 1 array as my data drive. I added the SSD drive and in the RAID setup, configured it as a RAID 0 array of only one disk. Then, I tried to do a clean install of windows 7 64-bit, but got stuck in the "Missing driver for CD/DVD drive" black hole of selecting driver files and Windows telling me that i don't have the appropriate driver for my hardware. The missing hardware is NOT a CD/DVD drive, since i'm installing off of my only CD/DVD drive. Plus at one point i was able to point it at a driver for my raid controller, and then my hard drives magically showed up as browsable sources for finding drivers for some other unnamed device that setup couldn't recognize. After a few hours of trying drivers (this was a very slow process) i decided to reboot and look at the BIOS settings. I'm using an ASUS M2A-VM motherboard which has an ATI SB600 RAID controller on board. I switched the "On board SATA Type" setting from "SATA" to "AHCI" thinking that since AHCI is an Intel thing, this would help. Unfortunately, this abandoned my RAID configuration, and my previously mirrored drives are showing up as separate drives when i boot into my current windows installation. Am i trying to do the impossible here? Should i just buy a separate SATA/RAID PCI card and plug the SSD into that? Any help would be greatly appreciated.

    Read the article

  • Data recovery on working hard drive

    - by emgee
    So I have a 5 bay hot swap SATA enclosure that's connected to a Silicon Image-based SATA adapter in a computer. It's running XP Pro. There are two 1.5TB hard drives in slots 1 and 2 respectively, set up using RAID 1 using the the Silicon Image utility. There are also two 1TB drives in bays 3 and 4, also set to RAID 1 the same way. The partitions for both RAID arrays are Dynamic partitions. A few days back, there was a bare hard drive that needed some files copied off of, so it was popped it in bay 5, that bay to pass-through, and the copied data off of it. Later, I noticed that my 1.5TB drives no longer showed up in windows. In the Silicon Image utility, the drives showed up fine, no error. However, in Device Manager, it shows the RAID 1 array as uninitialized. It shows up as the right size, etc., but nothing else. There's no sign of anything wrong with either drive, so I'm not sure what happened exactly. I'm not the only one who has access to that computer, so it is possible there is something else done to it that I don't know of. There's quite a lot of data on it still, and if at all possible, I'd prefer to not send it to Ontrack. Does anyone know of software that would restore the partitions, keeping in mind that it's a Windows LDM partition? I have access to a variety of Operating Systems, so something that would work on Mac, Windows or Linux would be acceptable. The programs I usually use are not compatible with LDM.

    Read the article

  • Restore Your PC from Windows Home Server

    - by Mysticgeek
    If your computer crashes or you get a virus infection that makes it unrecoverable, doing a clean install can be a hassle, let alone getting your data back. If you’re backing up your computers to Windows Home Server, you can completely restore them to the last successful backup. Note: For this process to work you need to verify the PC you want to restore is connected to your network via Ethernet. If you have it connected wirelessly it won’t work. Restore a PC from Windows Home Server On the computer you want to restore, pop in the Windows Home Server Home Computer Restore disc and boot from it. If you don’t have one already made, you can easily make one following these instructions. We have also included the link to the restore disc below. Boot from the CD then select if your machine has 512MB or RAM or more. The disc will initialize… Then choose your language and keyboard settings. Hopefully if everything goes correctly, your network card will be detected and you can continue. However, if it doesn’t like in our example, click on the Show Details button. In the Detect Hardware screen click on the Install Drivers button. Now you will need to have a USB flash drive with the correct drivers on it. It has to be a flash drive or a floppy (if you happen to still have one of those) because you can’t take out the Restore CD. If you want to make sure you have the correct drivers on the USB flash drive, open the Windows Home Server Console on another computer on your network. In the Computers and Backup section right-click on the computer you want to restore and select View Backups. Select the backup you want to restore from and click the Open button in the Restore or view Files section. Now drag the entire contents of the folder named Windows Home Server Drivers for Restore to the USB flash drive. Back to the machine you’re trying to restore, insert the USB flash drive with the correct drivers and click the Scan button. Wait a few moments while the drivers are found then click Ok then Continue.   The Restore Computer Wizard starts up… Enter in your home server password and click Next. Select the computer you want to restore. If it isn’t selected by default you can pull it up from the dropdown list under Another Computer. Make certain you’re selecting the correct machine. Now select the backup you want to restore. In this example we only have one but chances are you’ll have several. If you have several backups to choose from, you might want to check out the details for them. Now you can select the disk from backup and and restore it to the destination volume. You might need to initialize a disk, change a drive letter, or other disk management tasks, if so, then click on Run Disk Manger. For example we want to change the destination drive letter to (C:).   After you’ve made all the changes to the destination disk you can continue with the restore process. If everything looks correct, confirm the restore configuration. If you need to make any changes at this point, you can still go back and make them. Now Windows Home Server will restore your drive. The amount of time it takes will vary depend on the amount of data you have to restore, network connection speed, and hardware. You are notified when the restore successfully completes. Click Finish and the PC will reboot and be restored and should be working correctly. All the updates, programs, and files will be back that were saved to the last successful backup. Anything you might have installed after that backup will be gone. If you have your computers set to backup every night, then hopefully it won’t be a big issue.   Conclusion Backing up the computers on your network to Windows Home Server is a valuable tool in your backup strategy. Sometimes you may only need to restore a couple files and we’ve covered how to restore them from backups on WHS and that works really well. If the unthinkable happens and you need to restore the entire computer, WHS makes that easy too.  Download Windows Home Server Home Computer Restore CD Similar Articles Productive Geek Tips Restore Files from Backups on Windows Home ServerCreate A Windows Home Server Home Computer Restore DiscGMedia Blog: Setting Up a Windows Home ServerShare Ubuntu Home Directories using SambaInstalling Windows Home Server TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional Make your Joomla & Drupal Sites Mobile with OSMOBI Integrate Twitter and Delicious and Make Life Easier Design Your Web Pages Using the Golden Ratio Worldwide Growth of the Internet How to Find Your Mac Address Use My TextTools to Edit and Organize Text

    Read the article

  • #OOW 2012 : IaaS, Private Cloud, Multitenant Database, and X3H2M2

    - by Eric Bezille
    The title of this post is a summary of the 4 announcements made by Larry Ellison today, during the opening session of Oracle Open World 2012... To know what's behind X3H2M2, you will have to wait a little, as I will go in order, beginning with the IaaS - Infrastructure as a Service - announcement. Oracle IaaS goes Public... and Private... Starting in 2004 with Fusion development, Oracle Cloud was launch last year to provide not only SaaS Application, based on standard development, but also the underlying PaaS, required to build the specifics, and required interconnections between applications, in and outside of the Cloud. Still, to cover the end-to-end Cloud  Services spectrum, we had to provide an Infrastructure as a Service, leveraging our Servers, Storage, OS, and Virtualization Technologies, all "Engineered Together". This Cloud Infrastructure, was already available for our customers to build rapidly their own Private Cloud either on SPARC/Solaris or x86/Linux... The second announcement made today bring that proposition a big step further : for cautious customers (like Banks, or sensible industries) who would like to benefits from the Cloud value of "as a Service", but don't want their Data out in the Cloud... We propose to them to operate the same systems, Exadata, Exalogic & SuperCluster, that are providing our Public Cloud Infrastructure, behind their firewall, in a Private Cloud model. Oracle 12c Multitenant Database This is also a major announcement made today, on what's coming with Oracle Database 12c : the ability to consolidate multiple databases with no extra additional  cost especially in terms of memory needed on the server node, which is often THE consolidation limiting factor. The principle could be compare to Solaris Zones, where, you will have a Database Container, who is "owning" the memory and Database background processes, and "Pluggable" Database in this Database Container. This particular feature is a strong compelling event to evaluate rapidly Oracle Database 12c once it will be available, as this is major step forward into true Database consolidation with Multitenancy on a shared (optimized) infrastructure. X3H2M2, enabling the new Exadata X3 in-Memory Database Here we are :  X3H2M2 stands for X3 (the new version of Exadata announced also today) Heuristic Hierarchical Mass Memory, providing the capability to keep most if not all the Data in the memory cache hierarchy. Of course, this is the major software enhancement of the new X3 Exadata machine, but as this is a software, our current customers would be able to benefit from it on their existing systems by upgrading to the new release. But that' not the only thing that we did with X3, at the same time we have upgraded everything : the CPUs, adding more cores per server node (16 vs. 12, with the arrival of Intel E5 / Sandy Bridge), the memory with 512GB memory as well per node,  and the new Flash Fire card, bringing now up to 22 TB of Flash cache. All of this 4TB of RAM + 22TB of Flash being use cleverly not only for read but also for write by the X3H2M2 algorithm... making a very big difference compare to traditional storage flash extension. But what does those extra performances brings to you on an already very efficient system: double your performances compare to the fastest storage array on the market today (including flash) and divide you storage price x10 at the same time... Something to consider closely this days... Especially that we also announced the availability of a new Exadata X3-2 8th rack : a good starting point. As you have seen a major opening for this year again with true innovation. But that was not the only thing that we saw today, as before Larry's talk, Fujitsu did introduce more in deep the up coming new SPARC processor, that they are co-developing with us. And as such Andrew Mendelsohn - Senior Vice President Database Server Technologies came on stage to explain that the next step after I/O optimization for Database with Exadata, was to accelerate the Database at execution level by bringing functions in the SPARC processor silicium. All in all, to process more and more Data... The big theme of the day... and of the Oracle User Groups Conferences that were also happening today and where I had the opportunity to attend some interesting sessions on practical use cases of Big Data one in Finances and Fraud profiling and the other one on practical deployment of Oracle Exalytics for Data Analytics. In conclusion, one picture to try to size Oracle Open World ... and you can understand why, with such a rich content... and this only the first day !

    Read the article

  • Could not resolve <fx:Script> to a component implementation.

    - by seref
    Hi, i created project with flexmojos maven archtype..i used flexmojos:flexbuilder and compile/run with FlashBuilder 4 everything is okay but when i try to compile project with flexmojos i got following error: [ERROR] Z:....\src\main\flex\Main.mxml:[6,-1] Could not resolve < fx:Script to a component implementation. [INFO] BUILD FAILURE my mxml: <?xml version="1.0" encoding="utf-8"?> <s:Application xmlns:fx="http://ns.adobe.com/mxml/2009" xmlns:s="library://ns.adobe.com/flex/spark" xmlns:mx="library://ns.adobe.com/flex/mx" width="100%" height="100%" creationComplete="application1_creationCompleteHandler(event)"> <fx:Script> <![CDATA[ import mx.controls.Alert; import mx.events.FlexEvent; protected function application1_creationCompleteHandler(event:FlexEvent):void { Alert.show("success!!!!") } ]]></fx:Script> </s:Application> pom.xml like: ...... <packaging>swf</packaging> ...... <properties> <flex-sdk.version>4.1.0.16076</flex-sdk.version> <flexmojos.version>3.8</flexmojos.version> </properties> ...... <build> <sourceDirectory>src/main/flex</sourceDirectory> <testSourceDirectory>src/test/flex</testSourceDirectory> <plugins> <plugin> <groupId>org.sonatype.flexmojos</groupId> <artifactId>flexmojos-maven-plugin</artifactId> <version>${flexmojos.version}</version> <extensions>true</extensions> <dependencies> <dependency> <groupId>com.adobe.flex</groupId> <artifactId>compiler</artifactId> <version>${flex-sdk.version}</version> <type>pom</type> </dependency> </dependencies> <configuration> <compiledLocales> <locale>en_US</locale> </compiledLocales> <mergeResourceBundle>true</mergeResourceBundle> <accessible>true</accessible> <optimize>true</optimize> <targetPlayer>10.0.0</targetPlayer> <showWarnings>true</showWarnings> <linkReport>true</linkReport> </configuration> </plugin> </plugins> </build> <dependencies> <!-- Flex framework resource bundles --> <dependency> <groupId>com.adobe.flex.framework</groupId> <artifactId>flex-framework</artifactId> <version>${flex-sdk.version}</version> <type>pom</type> </dependency> <!-- Include unit test dependencies. --> <dependency> <groupId>com.adobe.flexunit</groupId> <artifactId>flexunit</artifactId> <version>4.0-rc-1</version> <type>swc</type> <scope>test</scope> </dependency> </dependencies> ....... maven output compiler config : INFO] Flex compiler configurations: -compiler.external-library-path C:\...\.m2\repository\com\adobe\flex \framework\playerglobal\4.1.0.16076\10.0\playerglobal.swc -compiler.include-libraries= -compiler.library-path C:\...\.m2\repository\com\adobe\flex\framework \datavisualization\4.1.0.16076\datavisualization-4.1.0.16076.swc C:\... \.m2\repository\com\adobe\flex\framework\flash-integration \4.1.0.16076\flash-integration-4.1.0.16076.swc C:\...\.m2\repository \com\adobe\flex\framework\flex\4.1.0.16076\flex-4.1.0.16076.swc C:\... \.m2\repository\com\adobe\flex\framework\framework \4.1.0.16076\framework-4.1.0.16076.swc C:\...\.m2\repository\com\adobe \flex\framework\osmf\4.1.0.16076\osmf-4.1.0.16076.swc C:\... \.m2\repository\com\adobe\flex\framework\rpc \4.1.0.16076\rpc-4.1.0.16076.swc C:\...\.m2\repository\com\adobe\flex \framework\spark\4.1.0.16076\spark-4.1.0.16076.swc C:\... \.m2\repository\com\adobe\flex\framework\sparkskins \4.1.0.16076\sparkskins-4.1.0.16076.swc C:\...\.m2\repository\com\adobe \flex\framework\textLayout\4.1.0.16076\textLayout-4.1.0.16076.swc C: \...\.m2\repository\com\adobe\flex\framework\utilities \4.1.0.16076\utilities-4.1.0.16076.swc C:\...\.m2\repository\com\adobe \flex\framework\datavisualization \4.1.0.16076\datavisualization-4.1.0.16076-en_US.rb.swc C:\... \.m2\repository\com\adobe\flex\framework\framework \4.1.0.16076\framework-4.1.0.16076-en_US.rb.swc C:\...\.m2\repository \com\adobe\flex\framework\osmf\4.1.0.16076\osmf-4.1.0.16076- en_US.rb.swc C:\...\.m2\repository\com\adobe\flex\framework\rpc \4.1.0.16076\rpc-4.1.0.16076-en_US.rb.swc C:\...\.m2\repository\com \adobe\flex\framework\spark\4.1.0.16076\spark-4.1.0.16076-en_US.rb.swc C:\...\.m2\repository\com\adobe\flex\framework\textLayout \4.1.0.16076\textLayout-4.1.0.16076-en_US.rb.swc C:\...\.m2\repository \com\adobe\flex\framework\flash-integration\4.1.0.16076\flash- integration-4.1.0.16076-en_US.rb.swc C:\...\.m2\repository\com\adobe \flex\framework\playerglobal\4.1.0.16076\playerglobal-4.1.0.16076- en_US.rb.swc -compiler.theme Z:\.....\target\classes\configs\themes\Spark \spark.css -compiler.accessible=true -compiler.allow-source-path-overlap=false -compiler.as3=true -compiler.debug=false -compiler.es=false -compiler.fonts.managers flash.fonts.JREFontManager flash.fonts.BatikFontManager flash.fonts.AFEFontManager flash.fonts.CFFFontManager -compiler.fonts.local-fonts-snapshot Z:\.....\target\classes \fonts.ser -compiler.keep-generated-actionscript=false -licenses.license flashbuilder4 952309948800588759250406 -licenses.license flexbuilder4.displayedStartPageAtLeastOneTime true -compiler.locale en_US -compiler.optimize=true -compiler.source-path Z:\.....\src\main\flex -compiler.strict=true -use-network=true -compiler.verbose-stacktraces=false -compiler.actionscript-file-encoding UTF-8 -target-player 10.0.0 -default-background-color 8821927 -default-frame-rate 24 -default-script-limits 1000 60 -default-size 500 375 -compiler.headless-server=false -compiler.keep-all-type-selectors=false -compiler.use-resource-bundle-metadata=true -metadata.date Fri Mar 04 14:04:37 EET 2011 -metadata.localized-title Main x-default -verify-digests=true -compiler.namespaces.namespace+=http://ns.adobe.com/mxml/2009,Z:\..... \target\classes\config-4.1.0.16076\mxml-2009-manifest.xml -compiler.namespaces.namespace+=library://ns.adobe.com/flex/spark,Z: \.....\target\classes\config-4.1.0.16076\spark-manifest.xml -compiler.namespaces.namespace+=library://ns.adobe.com/flex/mx,Z:\..... \target\classes\config-4.1.0.16076\mx-manifest.xml -compiler.namespaces.namespace+=http://www.adobe.com/2006/mxml,Z:\..... \PozitronUI\target\classes\config-4.1.0.16076\mxml-manifest.xml - static-link-runtime-shared-libraries=false -load-config= -metadata.language+=en_US any help... regards,

    Read the article

  • YouTube API Security Error Flex

    - by 23tux
    Hi, I've tried to use the YoutTube API within a Flex project. But i got this error: *** Security Sandbox Violation *** SecurityDomain 'http://www.youtube.com/apiplayer?version=3' tried to access incompatible context 'file:///Users/YouTubePlayer/bin-debug/YouTubePlayer.html' Here are the two files: <?xml version="1.0" encoding="utf-8"?> <s:Application xmlns:fx="http://ns.adobe.com/mxml/2009" xmlns:s="library://ns.adobe.com/flex/spark" xmlns:mx="library://ns.adobe.com/flex/halo" minWidth="1024" minHeight="768" xmlns:youtube="youtube.*" creationComplete="init();"> <fx:Script> <![CDATA[ [Bindable] private var ready:Boolean = true; private function init():void { Security.allowInsecureDomain("*"); Security.allowDomain("*"); Security.allowDomain('www.youtube.com'); Security.allowDomain('youtube.com'); Security.allowDomain('s.ytimg.com'); Security.allowDomain('i.ytimg.com'); } private function changing():void { /* trace("currentTime: " + player.getCurrentTime()); trace("startTime: " + player.startTime); trace("stopTime: " + player.stopTime); timeSlider.value = player.getCurrentTime() */ } private function startPlaying():void { player.play(); } private function checkStartSlider():void { if(startSlider.value > stopSlider.value) stopSlider.value = startSlider.value + 1; } private function checkStopSlider():void { if(stopSlider.value < startSlider.value) startSlider.value = stopSlider.value - 1; } ]]> </fx:Script> <s:VGroup> <youtube:Player id="player" videoID="DVFvcVuWyfE" change="changing();" ready="ready=true"/> <s:HGroup> <s:Button label="play" click="startPlaying();" /> </s:HGroup> <s:HGroup> <s:HSlider id="timeSlider" width="250" minimum="0" maximum="{player.stopTime}" snapInterval=".01" enabled="{ready}"/> <s:Label id="currentTimeLbl" text="current time: 0" /> </s:HGroup> <s:HGroup> <s:HSlider id="startSlider" width="250" minimum="0" maximum="{player.stopTime}" snapInterval=".01" change="checkStartSlider();" enabled="{ready}" value="0"/> <s:Label id="startTimeLbl" text="start time: {player.startTime}" /> </s:HGroup> <s:HGroup> <s:HSlider id="stopSlider" width="250" minimum="0" maximum="{player.stopTime}" snapInterval=".01" change="checkStopSlider();" enabled="{ready}" value="{player.stopTime}"/> <s:Label id="stopTimeLbl" text="stop time: {player.stopTime}" /> </s:HGroup> </s:VGroup> </s:Application> Here is the player package youtube { import flash.display.Loader; import flash.events.Event; import flash.events.TimerEvent; import flash.net.URLRequest; import flash.system.Security; import flash.utils.Timer; import mx.core.UIComponent; [Event(name="change", type="flash.events.Event")] [Event(name="ready", type="flash.events.Event")] public class Player extends UIComponent { private var player:Object; private var loader:Loader; private var _startTime:Number = 0; private var _stopTime:Number = 0; private var _videoID:String; private var metadataTimer:Timer = new Timer(200); private var playTimer:Timer = new Timer(200); public function Player() { // The player SWF file on www.youtube.com needs to communicate with your host // SWF file. Your code must call Security.allowDomain() to allow this // communication. Security.allowInsecureDomain("*"); Security.allowDomain("*"); // This will hold the API player instance once it is initialized. loader = new Loader(); loader.contentLoaderInfo.addEventListener(Event.INIT, onLoaderInit); loader.load(new URLRequest("http://www.youtube.com/apiplayer?version=3")); } private function onLoaderInit(event:Event):void { addChild(loader); loader.content.addEventListener("onReady", onPlayerReady); loader.content.addEventListener("onError", onPlayerError); loader.content.addEventListener("onStateChange", onPlayerStateChange); loader.content.addEventListener("onPlaybackQualityChange", onVideoPlaybackQualityChange); } private function onPlayerReady(event:Event):void { // Event.data contains the event parameter, which is the Player API ID trace("player ready:", Object(event).data); // Once this event has been dispatched by the player, we can use // cueVideoById, loadVideoById, cueVideoByUrl and loadVideoByUrl // to load a particular YouTube video. player = loader.content; // Set appropriate player dimensions for your application player.setSize(0, 0); } private function onPlayerError(event:Event):void { // Event.data contains the event parameter, which is the error code trace("player error:", Object(event).data); } private function onPlayerStateChange(event:Event):void { // Event.data contains the event parameter, which is the new player state trace("player state:", Object(event).data); } private function onVideoPlaybackQualityChange(event:Event):void { // Event.data contains the event parameter, which is the new video quality trace("video quality:", Object(event).data); } [Bindable] public function get videoID():String { return _videoID; } public function set videoID(value:String):void { _videoID = value; } [Bindable] public function get stopTime():Number { return _stopTime; } public function set stopTime(value:Number):void { _stopTime = value; } [Bindable] public function get startTime():Number { return _startTime; } public function set startTime(value:Number):void { _startTime = value; } public function play():void { if(_videoID!="") { player.loadVideoById(_videoID, 0); // add the event listener, so that all 200 milliseconds is an event dispatched metadataTimer.addEventListener(TimerEvent.TIMER, metadataTimeHandler); // if the timer is running, stop and reset it if(metadataTimer.running) metadataTimer.reset(); else metadataTimer.start(); } } private function metadataTimeHandler(e:TimerEvent):void { if(player.getDuration() > 0) { startTime = 0; stopTime = player.getDuration(); metadataTimer.reset(); metadataTimer.stop(); metadataTimer.removeEventListener(TimerEvent.TIMER, metadataTimeHandler); player.playVideo(); playTimer.addEventListener(TimerEvent.TIMER, playTimerHandler); dispatchEvent(new Event("ready")); } } private function playTimerHandler(e:TimerEvent):void { if(getCurrentTime() > _stopTime) { seekTo(startTime); } dispatchEvent(new Event(Event.CHANGE)); } public function getCurrentTime():Number { if(!player.getCurrentTime()) return 0; else return player.getCurrentTime(); } public function seekTo(time:uint):void { player.seekTo(time); } } } Hope someone can help. thx, tux

    Read the article

  • Group Policy drive maps fail with Error Code: 0x80070043

    - by Topherhead
    I'm running a Server 2008 R2 domain with all Windows 7 x64 bit client machines. All drives are mapped using Group Policy. Which were previously on a NAS We just built a new, huge, fast server. So I'm in the process of migrating all the network drives from the NAS to the new fileserver(fs). The old drive maps were mapped using group policy so I just went in and updated to the new server and selected the "Replace" option. But the drives just plain do not map. I do an RSOP on my machine and the error for the drive map is: Result: Failure (Error Code: 0x80070043) The other odd thing, though it may or may not have anything to do with it, is that the winning GPO shown is shown with its SID instead of its name. The SID is correct though. Accessing the shares through Explorer works fine, and mapping them manually works fine. Any ideas? Thanks Chris

    Read the article

  • Troubleshooting PC

    - by srand
    After playing PC games after a few hours I decided to take a break. When I opened up My Computer in Windows 7 I noticed I one of my drives had disappeared. Thinking it was just a glitch, I tried to restart. Upon restart, the BIOS took forever to get through (I didn't notice my disappeared hard drive in the listed drives) and the computer seemed stuck at the "Starting Windows" screen. I hard shut down everything. Opened up the case, used canned air to clear the dust out and made sure all devices were snugly in place. I hooked everything up and powered on. This time, after a few seconds the computer restarted (nothing showed up on screen either). After its restart, the computer didn't do anything. The hard drive indicator light was on the whole time. What happened? :( PC Specs: Windows 7, 3GB RAM, Core 2 Duo, 3 Hard drives

    Read the article

  • Troubleshooting PC

    - by srand
    After playing PC games after a few hours I decided to take a break. When I opened up My Computer in Windows 7 I noticed I one of my drives had disappeared. Thinking it was just a glitch, I tried to restart. Upon restart, the BIOS took forever to get through (I didn't notice my disappeared hard drive in the listed drives) and the computer seemed stuck at the "Start Windows" screen. I hard shut down everything. Opened up the case, used canned air to clear the dust out and made sure all devices were snugly in place. I hooked everything up and powered on. This time, after a few seconds the computer restarted (nothing showed up on screen either). After its restart, the computer didn't do anything. The hard drive indicator light was on the whole time. What happened? :( PC Specs: Windows 7, 3GB RAM, Core 2 Duo, 3 Hard drives

    Read the article

  • How to install Windows 7 onto software RAID-0

    - by Jay B
    I recently got a new laptop (Asus G73JH-A2) which has two identical hard drives in it. Unfortunately the motherboard does not have a RAID controller. What I would like to do is run the drives in a RAID-0 configuration to improve performance (plus get the extra capacity on one partition). I would like Windows installed onto the striped volume (RAID 0). I have spent some time using diskpart to create a striped volume across the two drives, however when I go to install windows and select the volume it will not let me select 'Next' giving the error "Windows cannot be installed to this hard disk space. The partition contains one or more dynamic volumes that are not supported for installation." I'm hoping theres a step that I am missing that will allow me to install windows on a striped volume. Any ideas?

    Read the article

< Previous Page | 166 167 168 169 170 171 172 173 174 175 176 177  | Next Page >