Search Results

Search found 19245 results on 770 pages for 'paper size'.

Page 178/770 | < Previous Page | 174 175 176 177 178 179 180 181 182 183 184 185  | Next Page >

  • IRP_MJ_WRITE latency up to 15 seconds

    - by racitup
    We have written an application that performs small (22kB) writes to multiple files at once (one thread performing asynchronous queued writes to multiple locations on behalf of other threads) on the same local volume (RAID1). 99.9% of the writes are low-latency but occasionally (maybe every minute or two) we get one or two huge latency writes (I have seen 10 seconds and above) without any real explanation. Platform: Win2003 Server with NTFS. Monitoring: Sysinternals Process Monitor (see link below) and our own application logging. We have tried multiple things to try and solve this that have been gleaned from a few websites, e.g.: Making the first part of file names unique to aid 8.3 name generation Writing files to multiple directories Changing Intel Disk Write Caching Windows File/Printer Sharing Minimize memory used Balance Maximize data throughput for file sharing Maximize data throughput for network applications System-Advanced-Performance-Advanced NtfsDisableLastAccessUpdate - use fsutil behavior set disablelastaccess 1 disable 8.3 name generation - use "fsutil behavior set disable8dot3 1" + restart Enable a large size file system cache Disable paging of the kernel code IO Page Lock Limit Turn Off (or On) the Indexing Service But nothing seems to make much difference. There's a whole host of things we haven't tried yet but we wondered if anyone had come across the same problem, a reason and a solution (programmatic or not)? We can reproduce the problem using IOMeter and a simple setup: Start IOMeter and remove all but the first worker thread in 'Topology' using the disconnect button. Select the Worker thread and put a cross in the box next to the disk you want to use in the Disk Targets tab and put '2000000' in Maximum Disk Size (NOTE: must have at least 1GB free space; sector size is 512 bytes) Next create a new access specification and add it to the worker thread: Transfer Request Size = 22kB 100% Sequential Percent of Access Spec = 100% Percent Read/Write = 100% Write Change Results Display Update Frequency to 5 seconds, Test Setup Run Time to 20 seconds and both 'Number of Workers to Spawn Automatically' settings to zero. Select the Worker Thread in the Topology panel and hit the Duplicate Worker button 59 times to create 60 threads with identical settings. Hit the 'Go' button (green flag) and monitor the Results tab. The 'Maximum I/O Response Time (ms)' always hits at least 3500 on our machine. Our machine isn't exactly slow (Xeon 8 core rack server with 4GB and onboard RAID). I'd be interested to see what other people get. We have a feeling it might be something to do with the NTFS filesystem (ours is currently 75% full of fragmented files) and we are going to try a few things around this principle. But it is also related to disk performance since we don't see it on a RAMDisk and it's not as severe on a RAID10 array. Any help is much appreciated. Richard Right-click and select 'Open Link in New Tab': ProcMon Result

    Read the article

  • Using a 64bit Linux kernel, can't see more than 4GB of RAM in /proc/meminfo

    - by Chris Huang-Leaver
    I'm running my new computer which has 8GB of RAM installed, which is visable from BIOS page, does not show in /proc/meminfo uname -a Linux localhost 3.0.6-gentoo #2 SMP PREEMPT Sat Nov 19 10:45:22 GMT-- x86_64 AMD Phenom(tm) II X4 955 Processor AuthenticAMD GNU/Linux The result of /proc/meminfo is as follows: (thans Andrey) MemTotal: 4021348 kB MemFree: 1440280 kB Buffers: 23696 kB Cached: 1710828 kB SwapCached: 4956 kB Active: 1389904 kB Inactive: 841364 kB Active(anon): 1337812 kB Inactive(anon): 714060 kB Active(file): 52092 kB Inactive(file): 127304 kB Unevictable: 32 kB Mlocked: 32 kB SwapTotal: 8388604 kB SwapFree: 8047900 kB Dirty: 0 kB Writeback: 0 kB AnonPages: 492732 kB Mapped: 47528 kB Shmem: 1555120 kB Slab: 267724 kB SReclaimable: 177464 kB SUnreclaim: 90260 kB KernelStack: 1176 kB PageTables: 12148 kB NFS_Unstable: 0 kB Bounce: 0 kB WritebackTmp: 0 kB CommitLimit: 10399276 kB Committed_AS: 3293896 kB VmallocTotal: 34359738367 kB VmallocUsed: 317008 kB VmallocChunk: 34359398908 kB AnonHugePages: 120832 kB HugePages_Total: 0 HugePages_Free: 0 HugePages_Rsvd: 0 HugePages_Surp: 0 Hugepagesize: 2048 kB DirectMap4k: 23552 kB DirectMap2M: 3088384 kB DirectMap1G: 1048576 kB I have tried using mem=8G as a kernel boot parameter, I read a post about setting HIGHMEM64G to yes, before realising that only applies to 32bit kernels. Trying dmindecode -t memory SMBIOS 2.7 present. Handle 0x0026, DMI type 16, 23 bytes Physical Memory Array Location: System Board Or Motherboard Use: System Memory Error Correction Type: Multi-bit ECC Maximum Capacity: 32 GB Error Information Handle: Not Provided Number Of Devices: 4 Handle 0x0028, DMI type 17, 34 bytes Memory Device Array Handle: 0x0026 Error Information Handle: Not Provided Total Width: 64 bits Data Width: 64 bits Size: 4096 MB Form Factor: DIMM Set: None Locator: DIMM0 Bank Locator: BANK0 Type: <OUT OF SPEC> Type Detail: Synchronous Speed: 1333 MHz Manufacturer: Manufacturer0 Serial Number: SerNum0 Asset Tag: AssetTagNum0 Part Number: Array1_PartNumber0 Rank: Unknown Handle 0x002A, DMI type 17, 34 bytes Memory Device Array Handle: 0x0026 Error Information Handle: Not Provided Total Width: Unknown Data Width: 64 bits Size: No Module Installed Form Factor: DIMM Set: None Locator: DIMM1 Bank Locator: BANK1 Type: Unknown Type Detail: Synchronous Speed: Unknown Manufacturer: Manufacturer1 Serial Number: SerNum1 Asset Tag: AssetTagNum1 Part Number: Array1_PartNumber1 Rank: Unknown Handle 0x002C, DMI type 17, 34 bytes Memory Device Array Handle: 0x0026 Error Information Handle: Not Provided Total Width: 64 bits Data Width: 64 bits Size: 4096 MB Form Factor: DIMM Set: None Locator: DIMM2 Bank Locator: BANK2 Type: <OUT OF SPEC> Type Detail: Synchronous Speed: 1333 MHz Manufacturer: Manufacturer2 Serial Number: SerNum2 Asset Tag: AssetTagNum2 Part Number: Array1_PartNumber2 Rank: Unknown Handle 0x002E, DMI type 17, 34 bytes Memory Device Array Handle: 0x0026 Error Information Handle: Not Provided Total Width: Unknown Data Width: 64 bits Size: No Module Installed Form Factor: DIMM Set: None Locator: DIMM3 Bank Locator: BANK3 Type: Unknown Type Detail: Synchronous Speed: Unknown Manufacturer: Manufacturer3 Serial Number: SerNum3 Asset Tag: AssetTagNum3 Part Number: Array1_PartNumber3 Rank: Unknown

    Read the article

  • How to compact a registry hive?

    - by SLaks
    I'm using a (non-administrator) roaming profile, with a size limit of 4MB. As you can imagine, it is extremely difficult to stay within that size limit. I've noticed that NTUser.dat, which holds my HKEY_CURRENT_USER hive, is 2560KB, single-handedly using more than half of that limit. Is there any way to shrink the hive without administrator privileges? I don't mind losing any settings or preferences stored in it.

    Read the article

  • SVN checkout/export too long to download

    - by user41671
    Hi, My checkout/export session in svn is kinda weird. The file is just a 300KB in size but the downloading keeps going and it reaches a megabytes in size. The file is in RPM format. I don't know if the file is corrupt or the SVN has a bug. I tried to download the file using web browser and seems the downloading works fine. What probably is the main problem is here?

    Read the article

  • SVN checkout/export too long to download

    - by sasayins
    Hi, My checkout/export session in svn is kinda weird. The file is just a 300KB in size but the downloading keeps going and it reaches a megabytes in size. The file is in RPM format. I don't know if the file is corrupt or the SVN has a bug. I tried to download the file using web browser and seems the downloading works fine. What probably is the main problem is here?

    Read the article

  • LUKS with LVM, mount is not persistent after reboot

    - by linxsaga
    I have created a Logical vol and used luks to encrypt it. But while rebooting the server. I get a error message (below), therefore I would have to enter the root pass and disable the /etc/fstab entry. So mount of the LUKS partition is not persistent during reboot using LUKS. I have this setup on RHEL6 and wondering what i could be missing. I want to the LV to get be mount on reboot. Later I would want to replace it with UUID instead of the device name. Error message on reboot: "Give root password for maintenance (or type Control-D to continue):" Here are the steps from the beginning: [root@rhel6 ~]# pvcreate /dev/sdb Physical volume "/dev/sdb" successfully created [root@rhel6 ~]# vgcreate vg01 /dev/sdb Volume group "vg01" successfully created [root@rhel6 ~]# lvcreate --size 500M -n lvol1 vg01 Logical volume "lvol1" created [root@rhel6 ~]# lvdisplay --- Logical volume --- LV Name /dev/vg01/lvol1 VG Name vg01 LV UUID nX9DDe-ctqG-XCgO-2wcx-ddy4-i91Y-rZ5u91 LV Write Access read/write LV Status available # open 0 LV Size 500.00 MiB Current LE 125 Segments 1 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 253:0 [root@rhel6 ~]# cryptsetup luksFormat /dev/vg01/lvol1 WARNING! ======== This will overwrite data on /dev/vg01/lvol1 irrevocably. Are you sure? (Type uppercase yes): YES Enter LUKS passphrase: Verify passphrase: [root@rhel6 ~]# mkdir /house [root@rhel6 ~]# cryptsetup luksOpen /dev/vg01/lvol1 house Enter passphrase for /dev/vg01/lvol1: [root@rhel6 ~]# mkfs.ext4 /dev/mapper/house mke2fs 1.41.12 (17-May-2010) Filesystem label= OS type: Linux Block size=1024 (log=0) Fragment size=1024 (log=0) Stride=0 blocks, Stripe width=0 blocks 127512 inodes, 509952 blocks 25497 blocks (5.00%) reserved for the super user First data block=1 Maximum filesystem blocks=67633152 63 block groups 8192 blocks per group, 8192 fragments per group 2024 inodes per group Superblock backups stored on blocks: 8193, 24577, 40961, 57345, 73729, 204801, 221185, 401409 Writing inode tables: done Creating journal (8192 blocks): done Writing superblocks and filesystem accounting information: done This filesystem will be automatically checked every 21 mounts or 180 days, whichever comes first. Use tune2fs -c or -i to override. [root@rhel6 ~]# mount -t ext4 /dev/mapper/house /house PS: HERE I have successfully mounted: [root@rhel6 ~]# ls /house/ lost+found [root@rhel6 ~]# vim /etc/fstab -> as follow /dev/mapper/house /house ext4 defaults 1 2 [root@rhel6 ~]# vim /etc/crypttab -> entry as follows house /dev/vg01/lvol1 password [root@rhel6 ~]# mount -o remount /house [root@rhel6 ~]# ls /house/ lost+found [root@rhel6 ~]# umount /house/ [root@rhel6 ~]# mount -a -> SUCCESSFUL AGAIN [root@rhel6 ~]# ls /house/ lost+found Please let me know if I am missing anything here. Thanks in advance.

    Read the article

  • How to make Windows 7 machine allocate a lot of hard disk cache?

    - by Jian Lin
    I am recording some game play capture (recording playing of PS3 or Wii) using a PC with Windows 7 and Hauppauge 1212 HD Recorder, and I have 4GB of RAM... is there a way to increase the size of Windows 7's hard disk cache size so that writing to the hard drive can be super fast? Since there is at least 1.5GB of RAM not being used, something like allocating 1GB just as hard disk cache, is it possible?

    Read the article

  • Adaptec 5805 after reboot don't starting

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not included. It only works if the computer is shut down and turn off. Late i update firmware "Adaptec RAID 5805 Firmware Build 18948" How to fix the problem? add Log Configuration summary Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priorityHigh Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1 List item

    Read the article

  • How to run Windows 7 On-Screen Keyboard in Windows XP?

    - by frbry
    I'm searching for an OSK application for Windows XP that can be resized. It also must save the new size of the windows so the next time it starts, remember the previous size. The one coming along with Windows 7 is the perfect match. But unfortunately it must run on WinXP. So... Thanks in advance.

    Read the article

  • Slow Windows Explorer on Windows 7

    - by MadBoy
    I have Laptop with i7 (4 cores), 8GB ram and SSD OCZ Vertex 3 MaxIOPS which in testing that I did just now does 400mb/s+ read/write. However the responsiveness of Windows Explorer is far from being perfect. Opening up Computer, Documents, going into folders is very slow (1-5seconds). I don't have any viruses or spyware and I have tried changing properties to optimize view for General Items. I tried disabling Search Indexer but it made search in Outlook 2010 crawl and didn't bring any other effect. Even double clicking on file takes some time to open things up (like clicking a Word document). I don't have any drives mapped, my computer is not joined to domain. I have multiple VPN connections that I connect to but they all have disabled default gateways. I tried using CC Cleaner or some Windows 7 Tweaks app to disable some things. I am power user using Visual Studio, Tortoise SVN and other developer/administration apps. Any non obvious ideas? Edit: So I've been trying to pinpoint where the issue comes from and it seems that straight after reboot Windows Explorer opens very fast, when I load 3-4 programs (Royal TS, Visual Studio, Outlook) it's noticeably slower and the more programs I have it gets worse. After I start closing programs it starts working better and if I leave 2 open it's fast again. I tried doing some research with DiskMon and other programs from sysinternals but couldn't find anything suspicious. Below are stats during normal usage with a lots of programs open: - Ram usage with a lot of programs open and no swap file (i disabled it for testing): 6.95GB - CPU usage: 15%, none of the cores takes more then 50% (I have VS 2010 open x 4) HD Tune Pro: OCZ-VERTEX3 MI Benchmark Test capacity: full Read transfer rate Transfer Rate Minimum : 363.9 MB/s Transfer Rate Maximum : 505.5 MB/s Transfer Rate Average : Access Time : Burst Rate : CPU Usage : HD Tune Pro: OCZ-VERTEX3 MI File Benchmark Drive C: Transfer rate test File Size: 500 MB Sequential read 484102 KB/s Sequential write 444714 KB/s Random read 7779 IOPS Random write 16888 IOPS Random read (queue depth = 32) 73007 IOPS Random write (queue depth = 32) 69790 IOPS HD Tune Pro: OCZ-VERTEX3 MI Random Access Test capacity: full Read test Transfer size operations / sec avg. access time max. access time avg. speed 512 bytes 3260 IOPS 0.306 ms 2.106 ms 1.592 MB/s 4 KB 4161 IOPS 0.240 ms 2.006 ms 16.256 MB/s 64 KB 2382 IOPS 0.419 ms 2.367 ms 148.934 MB/s 1 MB 449 IOPS 2.225 ms 4.197 ms 449.407 MB/s Random 809 IOPS 1.235 ms 6.551 ms 410.527 MB/s HD Tune Pro: OCZ-VERTEX3 MI Extra Tests Test capacity: full Random seek 3975 IOPS 0.252 ms 1.941 MB/s Random seek 4 KB 4245 IOPS 0.236 ms 16.583 MB/s Butterfly seek 4086 IOPS 0.245 ms 1.995 MB/s Random seek / size 64 KB 3812 IOPS 0.262 ms 58.606 MB/s Random seek / size 8 MB 120 IOPS 8.348 ms 485.737 MB/s Sequential outer 4524 IOPS 0.221 ms 282.721 MB/s Sequential middle 4429 IOPS 0.226 ms 276.818 MB/s Sequential inner 5504 IOPS 0.182 ms 344.000 MB/s Burst rate 4472 IOPS 0.224 ms 279.475 MB/s

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Hi! Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • remote desktop client with panning of large desktops?

    - by mikewse
    When using the standard Windows remote desktop client in Full Screen to connect to a large remote desktop, the result is usually that the remote desktop is resized to a smaller size matching the local display. Are there any RDP clients that in Full Screen instead leave the remote desktop at its original size and pan this larger area when the mouse reaches the border edges of the local display? Thanks Mike

    Read the article

  • Can we decrease page swapping?

    - by Benjamin
    My system has a 5GB RAM. And my paging file size is 2GB Even though I have many RAM, page-swapping still occurs. But I don't want to swapping. If I resize the paging file size(ex 200MB?), Doesn't Windows System do any swapping? Are there side-effects?

    Read the article

  • I/O intensive MySql server on Amazon AWS

    - by rhossi
    We recently moved from a traditional Data Center to cloud computing on AWS. We are developing a product in partnership with another company, and we need to create a database server for the product we'll release. I have been using Amazon Web Services for the past 3 years, but this is the first time I received a spec with this very specific hardware configuration. I know there are trade-offs and that real hardware will always be faster than virtual machines, and knowing that fact forehand, what would you recommend? 1) Amazon EC2? 2) Amazon RDS? 3) Something else? 4) Forget it baby, stick to the real hardware Here is the hardware requirements This server will be focused on I/O and MySQL for the statistics, memory size and disk space for the images hosting. Server 1 I/O The very main part on this server will be I/O processing, FusionIO cards have proven themselves extremely efficient, this is currently the best you can have in this domain. o Fusion ioDrive2 MLC 365GB (http://www.fusionio.com/load/-media-/1m66wu/docsLibrary/FIO_ioDrive2_Datasheet.pdf) CPU MySQL will use less CPU cores than Apache but it will use them very hard, the E7 family has 30M Cache L3 wichi provide boost performance : o 1x Intel E7-2870 will be ok. Storage SAS will be good enough in terms of performance, especially considering the space required. o RAID 10 of 4 x SAS 10k or 15k for a total available space of 512 GB. Memory o 64 GB minimum is required on this server considering the size of the statistics database. Warning: the statistics database will grow quickly, if possible consider starting with 128 GB directly, it will help. This server will be focused on I/O and MySQL for the statistics, memory size and disk space for the images hosting. Server 2 I/O The very main part on this server will be I/O processing, FusionIO cards have proven themselves extremely efficient, this is currently the best you can have in this domain. o Fusion ioDrive2 MLC 365GB (http://www.fusionio.com/load/-media-/1m66wu/docsLibrary/FIO_ioDrive2_Datasheet.pdf) CPU MySQL will use less CPU cores than Apache but it will use them very hard, the E7 family has 30M Cache L3 wichi provide boost performance : o 1x Intel E7-2870 will be ok. Storage SAS will be good enough in terms of performance, especially considering the space required. o RAID 10 of 4 x SAS 10k or 15k for a total available space of 512 GB. Memory o 64 GB minimum is required on this server considering the size of the statistics database. Warning: the statistics database will grow quickly, if possible consider starting with 128 GB directly, it will help. Thanks in advance. Best,

    Read the article

  • RAID 50 24Port Fast Writes Slow Reads - Ubuntu

    - by James
    What is going on here?! I am baffled. serveradmin@FILESERVER:/Volumes/MercuryInternal/test$ sudo dd if=/dev/zero of=/Volumes/MercuryInternal/test/test.fs bs=4096k count=10000 10000+0 records in 10000+0 records out 41943040000 bytes (42 GB) copied, 57.0948 s, 735 MB/s serveradmin@FILESERVER:/Volumes/MercuryInternal/test$ sudo dd if=/Volumes/MercuryInternal/test/test.fs of=/dev/null bs=4096k count=10000 10000+0 records in 10000+0 records out 41943040000 bytes (42 GB) copied, 116.189 s, 361 MB/s OF NOTE: My RAID50 is 3 sets of 8 disks. - This might not be the best config for SPEED. OS: Ubuntu 12.04.1 x64 Hardware Raid: RocketRaid 2782 - 24 Port Controller HardDriveType: Seagate Barracuda ES.2 1TB Drivers: v1.1 Open Source Linux Drivers. So 24 x 1TB drives, partitioned using parted. Filesystem is ext4. I/O scheduler WAS noop but have changed it to deadline with no seemingly performance benefit/cost. serveradmin@FILESERVER:/Volumes/MercuryInternal/test$ sudo gdisk -l /dev/sdb GPT fdisk (gdisk) version 0.8.1 Partition table scan: MBR: protective BSD: not present APM: not present GPT: present Found valid GPT with protective MBR; using GPT. Disk /dev/sdb: 41020686336 sectors, 19.1 TiB Logical sector size: 512 bytes Disk identifier (GUID): 95045EC6-6EAF-4072-9969-AC46A32E38C8 Partition table holds up to 128 entries First usable sector is 34, last usable sector is 41020686302 Partitions will be aligned on 2048-sector boundaries Total free space is 5062589 sectors (2.4 GiB) Number Start (sector) End (sector) Size Code Name 1 2048 41015625727 19.1 TiB 0700 primary To me this should be working fine. I can't think of anything that would be causing this other then fundamental driver errors? I can't seem to get much/if any higher then the 361MB a second, is this hitting the "SATA2" link speed, which it shouldn't given it is a PCIe2.0 card. Or maybe some cacheing quirk - I do have Write Back enabled. Does anyone have any suggestions? Tests for me to perform? Or if you require more information, I am happy to provide it! This is a video fileserver for editing machines, so we have a preference for FAST reads over writes. I was just expected more from RAID 50 and 24 drives together... EDIT: (hdparm results) serveradmin@FILESERVER:/Volumes/MercuryInternal$ sudo hdparm -Tt /dev/sdb /dev/sdb: Timing cached reads: 17458 MB in 2.00 seconds = 8735.50 MB/sec Timing buffered disk reads: 884 MB in 3.00 seconds = 294.32 MB/sec EDIT2: (config details) Also, I am using a RAID block size of 256K. I was told a larger block size is better for larger (in my case large video) files. EDIT3: (Bonnie++ Results. Would love some guidance with this!)

    Read the article

  • Dovecot, Postfix, Postfixadmin - can't send/receive mail

    - by Jack
    I am setting up a mail server: Dovecot and Postfix with MySQL support and Postfixadmin. Spend literally all day trying to figure it out, but I'm still unable to neither send nor receive any emails. To my knowledge, I have configured everything correctly, so either there is another problem, or my knowledge isn't good enough. Here is what I get when I use "echo test | mail [email protected]:" Jul 11 00:41:07 server postfix/pickup[17999]: 5B0D32AE1B: uid=0 from= Jul 11 00:41:07 server postfix/cleanup[19444]: 5B0D32AE1B: message-id=<[email protected] Jul 11 00:41:07 server postfix/qmgr[18513]: 5B0D32AE1B: from=, size=329, nrcpt=1 (queue active) Jul 11 00:41:12 server postfix/smtp[19448]: 5B0D32AE1B: to=, relay=none, delay=5.3, delays=0.1/0.01/5.2/0, dsn=4.4.3, status=deferred (Host or domain name not found. Name service error for name=dsa.com type=MX: Host not found, try again) *@mail.asd.com is changed for privacy reasons, same goes for [email protected]. *The bold text is where it, for some reason, prints out dsa.com - even though I haven't found it anywhere in the files which I've edited during the installation, nor my DNS is .com in the first place. Here is what I get when I try to send out an email from Postfix Admin interface: Jul 11 00:49:08 server postfix/smtpd[19479]: connect from localhost[127.0.0.1] Jul 11 00:49:08 server postfix/trivial-rewrite[19484]: warning: do not list domain asd.com in BOTH mydestination and virtual_mailbox_domains Jul 11 00:49:08 server postfix/smtpd[19479]: 4F7892AE1E: client=localhost[127.0.0.1] Jul 11 00:49:08 server postfix/cleanup[19487]: 4F7892AE1E: message-id=<[email protected] Jul 11 00:49:08 server postfix/qmgr[18513]: 4F7892AE1E: from=, size=317, nrcpt=1 (queue active) Jul 11 00:49:08 server postfix/smtpd[19479]: disconnect from localhost[127.0.0.1] Jul 11 00:49:10 server postfix/smtpd[19492]: connect from localhost[127.0.0.1] Jul 11 00:49:10 server postfix/trivial-rewrite[19484]: warning: do not list domain asd.com in BOTH mydestination and virtual_mailbox_domains Jul 11 00:49:10 server postfix/smtpd[19492]: 743AE2AE1F: client=localhost[127.0.0.1] Jul 11 00:49:10 server postfix/cleanup[19487]: 743AE2AE1F: message-id=<[email protected] Jul 11 00:49:10 server postfix/qmgr[18513]: 743AE2AE1F: from=, size=772, nrcpt=1 (queue active) Jul 11 00:49:10 server postfix/smtpd[19492]: disconnect from localhost[127.0.0.1] Jul 11 00:49:10 server amavis[13437]: (13437-11) Passed CLEAN, LOCAL [127.0.0.1] - , Message-ID: <[email protected], mail_id: 86+KQY93ANel, Hits: -0.002, size: 317, queued_as: 743AE2AE1F, 2145 ms Jul 11 00:49:10 server postfix/smtp[19489]: 4F7892AE1E: to=, relay=127.0.0.1[127.0.0.1]:10024, delay=2.3, delays=0.17/0.01/0/2.1, dsn=2.0.0, status=sent (250 2.0.0 from MTA([127.0.0.1]:10025): 250 2.0.0 Ok: queued as 743AE2AE1F) Jul 11 00:49:10 server postfix/qmgr[18513]: 4F7892AE1E: removed I really don't know what might be the problem... If you need to know something, feel free to ask and I'll clarify something.

    Read the article

  • Is it possible to resize the existing mac partion

    - by Mirage
    I have existing MAC partition of 16GB. But my hardisk is 40GB. I want to increase the size of MAC OS . I have created another virtual disk of 30 GB which is appearing on MAC as well. BUT what should i do to re-size the MAC partition. I can make the image of system as it says resource busy. how can i make image of system

    Read the article

  • How to update OSX when space is tight?

    - by Nick L
    Software Update has notified me of a new OSX system update (including the Mac App Store). It claims to be about 1.6GB in size. I have 4.6GB of free space on my hard drive. However, when I attempt to actually run the update, it fails because it claims to need 6.9GB of free space. Is there any particular reason Software Update needs so much space beyond the downloaded file size and are there any work arounds? Thanks.

    Read the article

  • perf tuning for ESX vmfs3 on RAID

    - by maruti
    looking for recommendations on ESX4 OS - VMFS version3: RAID-5 : matching the stripe size with VMFS block size? (64K, 128K etc) RAID controller options: "adaptive read ahead, write-back" on PERC 6i 90% VMs on server are Windows (2008, 2003, Vista etc, SQL 2005 etc) i have read that smaller stipes are good for writes and larger for reads. Since this is virtual env, not sure whats good.

    Read the article

  • Why are the analoge stereo input and output of my M-Audio 24/96 soundcard not available to me in Ubu

    - by user37968
    I have installed Lucid on an old Mac PowerPC G4 desktop with a M-Audio Audiophile 24/96 soundcard. The only inputs and outputs I can select in the audio preferences are digital ones for the digital input and output. "lspci -v" shows the card as so: 0001:10:13.0 Multimedia audio controller: VIA Technologies Inc. ICE1712 [Envy24] PCI Multi-Channel I/O Controller (rev 02) Subsystem: VIA Technologies Inc. Device d634 Flags: bus master, medium devsel, latency 16, IRQ 53 I/O ports at 0440 [size=32] I/O ports at 04b0 [size=16] I/O ports at 04a0 [size=16] I/O ports at 0400 [size=64] Capabilities: <access denied> Kernel driver in use: ICE1712 Kernel modules: snd-ice1712 "cat /proc/asound/cards" as so: 0 [Tumbler ]: PMac Tumbler - PowerMac Tumbler PowerMac Tumbler (Dev 21) Sub-frame 0 1 [M2496 ]: ICE1712 - M Audio Audiophile 24/96 M Audio Audiophile 24/96 at 0x440, irq 53 "aplay -L" shows these as listed: pulse Playback/recording through the PulseAudio sound server front:CARD=Tumbler,DEV=0 PowerMac Tumbler, PowerMac Tumbler Front speakers front:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi Front speakers surround40:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 4.0 Surround output to Front and Rear speakers surround41:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 4.1 Surround output to Front, Rear and Subwoofer speakers surround50:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 5.0 Surround output to Front, Center and Rear speakers surround51:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 5.1 Surround output to Front, Center, Rear and Subwoofer speakers iec958:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi IEC958 (S/PDIF) Digital Audio Output I believe it is a problem with detecting the analogue input/output. Sometimes I can get sound from the device but it is a sheet of white noise and tinkering makes it go away again I don't know if that is a separate problem or if it is linked to not being able to see the analogue input/outputs in the sound preferences. Any help would be greatly appreciated As for the white noise I have installed the Envy24 control panel and spend lots of time playing with the settings but when I can get the white noise I can never get it to an quality where I can actually hear what is being played. The internal speaker plays audio fine and plugging in a NI Audio 4DJ via usb also plays sound, although with some static but I believe that is due to an underpowered usb2 pci expansion card not being able to get enough electricity to the device. Alternatively I have seen other people with problems with this device so it may be a bug in the driver but that is another matter. I would like to get the M-Audio card working so I can begin to enjoy my music once again. As a note, I do not currently have any audio equipment capable of sending or receiving audio via the digital inputs and output so I can not check if they are working. The sound preferences show a wide range of digital in and out options with various surround sound options but no analogue ins and outs.

    Read the article

  • Why are the analoge stereo input and output of my M-Audio 24/96 soundcard not available to me in Ubuntu Lucid

    - by MIDoubleKO
    I have installed Lucid on an old Mac PowerPC G4 desktop with a M-Audio Audiophile 24/96 soundcard. The only inputs and outputs I can select in the audio preferences are digital ones for the digital input and output. "lspci -v" shows the card as so: 0001:10:13.0 Multimedia audio controller: VIA Technologies Inc. ICE1712 [Envy24] PCI Multi-Channel I/O Controller (rev 02) Subsystem: VIA Technologies Inc. Device d634 Flags: bus master, medium devsel, latency 16, IRQ 53 I/O ports at 0440 [size=32] I/O ports at 04b0 [size=16] I/O ports at 04a0 [size=16] I/O ports at 0400 [size=64] Capabilities: <access denied> Kernel driver in use: ICE1712 Kernel modules: snd-ice1712 "cat /proc/asound/cards" as so: 0 [Tumbler ]: PMac Tumbler - PowerMac Tumbler PowerMac Tumbler (Dev 21) Sub-frame 0 1 [M2496 ]: ICE1712 - M Audio Audiophile 24/96 M Audio Audiophile 24/96 at 0x440, irq 53 "aplay -L" shows these as listed: pulse Playback/recording through the PulseAudio sound server front:CARD=Tumbler,DEV=0 PowerMac Tumbler, PowerMac Tumbler Front speakers front:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi Front speakers surround40:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 4.0 Surround output to Front and Rear speakers surround41:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 4.1 Surround output to Front, Rear and Subwoofer speakers surround50:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 5.0 Surround output to Front, Center and Rear speakers surround51:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi 5.1 Surround output to Front, Center, Rear and Subwoofer speakers iec958:CARD=M2496,DEV=0 M Audio Audiophile 24/96, ICE1712 multi IEC958 (S/PDIF) Digital Audio Output I believe it is a problem with detecting the analogue input/output. Sometimes I can get sound from the device but it is a sheet of white noise and tinkering makes it go away again I don't know if that is a separate problem or if it is linked to not being able to see the analogue input/outputs in the sound preferences. Any help would be greatly appreciated As for the white noise I have installed the Envy24 control panel and spend lots of time playing with the settings but when I can get the white noise I can never get it to an quality where I can actually hear what is being played. The internal speaker plays audio fine and plugging in a NI Audio 4DJ via usb also plays sound, although with some static but I believe that is due to an underpowered usb2 pci expansion card not being able to get enough electricity to the device. Alternatively I have seen other people with problems with this device so it may be a bug in the driver but that is another matter. I would like to get the M-Audio card working so I can begin to enjoy my music once again. As a note, I do not currently have any audio equipment capable of sending or receiving audio via the digital inputs and output so I can not check if they are working. The sound preferences show a wide range of digital in and out options with various surround sound options but no analogue ins and outs.

    Read the article

  • perf tuning for vmfs3 on RAID

    - by maruti
    recommendations for ESX4 OS - VMFS version3: matching: RAID-5 stripe size with VMFS block size? (64K, 128K etc) enabled "adaptive read ahead, write-back" on PERC 6i 90% VMs on server are Windows (2008, 2003, Vista etc, SQL 2005 etc) i have read that smaller stipes are good for writes and larger for reads. Since this is virtual env, not sure whats good.

    Read the article

  • Matching monitors

    - by JC
    Does anyone know a good matching monitor setup for multiple displays? Looking for 1920 x 1200 with IPS panel as the main screen and some 1600 x 1200 monitor for the side but no single manufacturer seems to make monitors that match like this. Do you all just deal with the resolution and size differences in multi setups or has anyone found decent IPS panel setups that match (size / vertical resolution)? Three 1920x1200 seems like overkill, that's why I was looking for 4:3 monitors for the sides.

    Read the article

  • setting upload/space limit for FTP client

    - by tombull89
    As part of my web hosting plan i've also got a few domain hosted for family and friends. I have my own FTP account with full access and I would like to give FTP to a web designer and a user. Is there a way for restricing uploads larger than a certian size, or setting a size limit on the folder that the FTP access has access to? I'd rather not let them upload files ridiciously big. Thanks.

    Read the article

< Previous Page | 174 175 176 177 178 179 180 181 182 183 184 185  | Next Page >