Search Results

Search found 1367 results on 55 pages for 'kyle west'.

Page 18/55 | < Previous Page | 14 15 16 17 18 19 20 21 22 23 24 25  | Next Page >

  • Mounting a Mail Store that is in a Recovery Storage group On Exchange 2003

    - by Kyle Brandt
    If I have a production server with the Mail Store Foo in both the storage group companyName and the Recovery Storage Group, is it okay to Mount Foo in the RSG while it is mounted in companyName so I can extract some mailboxs from the recovery storage group? Basically I am wonder if it is okay to mount it in both Production and the Recovery Storage Groups while the mail server is in production and the particular mail store is in production. Reference: "Once an RSG is restored into and mounted up you can connect to it with ExMerge and read out mailboxes into PST files for merging back into a 'live' store" -- http://serverfault.com/questions/49728/test-restore-of-exchange-dbs-with-the-ms-exchange-plugin-of-netbackup-6

    Read the article

  • Play music on iPhone through computer

    - by Kyle Cronin
    Now that I've had my iPhone for a few months, I'm trying an experiment to see if I can't replace the laptop I carry around with my iPhone + internet connected computer. To this end, I've been trying to find a program that will let me play the music on my iPhone through the hardware and software on the host computer. If I recall correctly this was possible a few years ago with the iPod - Linux software like Rhythmbox and Banshee was able to read the music off an iPod and play it through the speakers. I even thought I recalled iTunes itself being capable of this at one time. Now, however, iTunes greys out/disables the music on my iPhone and I can't find any documented support for the iPhone in any other music program. Is this really no longer possible? Am I limited to using the headphone jack to get music to play? (note: I am using an iPhone 3G with the 3.0 software. I am attempting to play music on computers other than the one I sync with) Several replies mention that I should check "manually manage" to do this. I just tried this on a computer that I don't sync my iPhone to and it asked me to erase and sync, which is obviously something I don't want to do. update: OK, I checked the "Manually manage music and videos" box on a computer that I didn't sync to (now known as "Computer A"), and it told me that I needed to erase & sync to cause the changes to have effect, so I did. At this point I'm guessing that my iPhone thinks that it's syncing with that computer. I copied over a few songs using the autofill feature. At this point, Computer A sees the maybe 10 or so songs I've copied using autofill. I then plug my iPhone into my Macbook ("Computer B") which I've been syncing with. At this point, I'm pretty sure that it still thought that all my synced content was still on my iPhone. The "manually manage music and videos" checkbox isn't checked, so I check it and go through a similar process where iTunes erases the synced content and I copy over a playlist. At this point, there's no trace of the songs that I copied over from Computer A. So I plug my iPhone into Computer A - in the Music section are the handful of songs that I had copied over earlier, greyed out and unplayable. To make sure that this wasn't some sort of caching issue, I plugged my iPhone into my sister's Macbook ("Computer C") and it lists the same few, greyed out songs that I had copied over from Computer A. Plugging into Computer B doesn't reveal these songs at all, only the songs that it copied over (these are playable). A few things: This inconsistent behavior is driving me insane. Why would my iPhone report two versions of its contents to different computers? Is there a way to get a computer to completely forget about an iPhone and just resync everything to get everything into a consistent state? Even if I get the phone into a consistent state, I still can't play the files on my phone anywhere but the computer I sync with, which was my original goal. What am I doing wrong? maybe I should read the fine print before I mess with my iPhone So going over this thread with a fine-toothed comb again yields this lovely tidbit in the Apple docs: Note: Even when manually managing, some content may only be available from one library at time. This includes all content on iPhone and video content on iPods. OK, so manually managing is a dead end on the iPhone. Are there any other options? Any unofficial third-party programs or drivers that will work?

    Read the article

  • PHP-CGI slowly gains memory despite lack of requests.

    - by Kyle
    I know by now that PHP-CGI will sit there and hog my memory but I'm not looking to reduce it, just a way to reset the processes every so often. I'm using PHP-CGI with FastCGI/Lighttpd. So the best way of saying this is how could I reset these processes to prevent these annoying memory leaks?

    Read the article

  • NSclient++ NRPE issues

    - by Kyle
    I have had NSclient++ working with Nagios for a while now. Recently I started testing Nagwin just to see how it would work, out of pure curiosity. I stopped checking a test server with my main Nagios config, set NSclient++ to NRPE mode, and pointed Nagwin at it. It worked great for a few hours then suddenly I started seeing "UNKNOWN: No Handler for that command." I figured it has to be Nagwin's fault since it's so new, I'll just unload NRPElistner.dll and return my server to being monitored by check_NT. However now check_NT doesn't work my main Nagios server returns timeout errors and is unable to connect at all. My Nagwin server can connect to it, the server just doesn't know how to handle the check_NRPE commands even though it did with no changes a few hours earlier. I have been working on this for a day now and am fairly certain it is NSclient++ who is to blame here. My nagwin box has successfully stayed connected to a similar server throughout the night, without any issues. And my main Nagios config is not having any problems at all. I have been able to successfully switch another server between being monitored by nagios and nagwin without any problems by simply loading and unloading the NRPE.dll. I have tried uninstalling NSclient++ and reinstalling with fresh configuration but still receive the errors. As of now the firewall is off on the server, NSclient++ is setup to accept connection from any server, there is no password, I have also turned ssl off, and the NRPE module is loaded. Any Ideas would be appreciated, I am not an advanced Nagios user but I do know my way around it and can easily break it down and set it up again. I also want to add that while in test mode NSclient++ is unable to handle check_NRPE commands there either.

    Read the article

  • Using Diskpart in a PowerShell script won't allow script to reuse drive letter

    - by Kyle
    I built a script that mounts (attach) a VHD using Diskpart, cleans out some system files and then unmounts (detach) it. It uses a foreach loop and is suppose to clean multiple VHD using the same drive letter. However, after the 1st VHD it fails. I also noticed that when I try to manually attach a VHD with diskpart, diskpart succeeds, the Disk Manager shows the disk with the correct drive letter, but within the same PoSH instance I can not connect (set-location) to that drive. If I do a manual diskpart when I 1st open PoSH I can attach and detach all I want and I get the drive letter every time. Is there something I need to do to reset diskpart in the script? Here's a snippet of the script I'm using. function Mount-VHD { [CmdletBinding()] param ( [Parameter(Position=0,Mandatory=$true,ValueFromPipeline=$false)] [string]$Path, [Parameter(Position=1,Mandatory=$false,ValueFromPipeline=$false)] [string]$DL, [string]$DiskpartScript = "$env:SystemDrive\DiskpartScript.txt", [switch]$Rescan ) begin { function InvokeDiskpart { Diskpart.exe /s $DiskpartScript } ## Validate Operating System Version ## if (Get-WmiObject win32_OperatingSystem -Filter "Version < '6.1'") {throw "The script operation requires at least Windows 7 or Windows Server 2008 R2."} } process{ ## Diskpart Script Content ## Here-String statement purposefully not indented ## @" $(if ($Rescan) {'Rescan'}) Select VDisk File="$Path" `nAttach VDisk Exit "@ | Out-File -FilePath $DiskpartScript -Encoding ASCII -Force InvokeDiskpart Start-Sleep -Seconds 3 @" Select VDisk File="$Path"`nSelect partition 1 `nAssign Letter="$DL" Exit "@ | Out-File -FilePath $DiskpartScript -Encoding ASCII -Force InvokeDiskpart } end { Remove-Item -Path $DiskpartScript -Force ; "" Write-Host "The VHD ""$Path"" has been successfully mounted." ; "" } } function Dismount-VHD { [CmdletBinding()] param ( [Parameter(Position=0,Mandatory=$true,ValueFromPipeline=$false)] [string]$Path, [switch]$Remove, [switch]$NoConfirm, [string]$DiskpartScript = "$env:SystemDrive\DiskpartScript.txt", [switch]$Rescan ) begin { function InvokeDiskpart { Diskpart.exe /s $DiskpartScript } function RemoveVHD { switch ($NoConfirm) { $false { ## Prompt for confirmation to delete the VHD file ## "" ; Write-Warning "Are you sure you want to delete the file ""$Path""?" $Prompt = Read-Host "Type ""YES"" to continue or anything else to break" if ($Prompt -ceq 'YES') { Remove-Item -Path $Path -Force "" ; Write-Host "VHD ""$Path"" deleted!" ; "" } else { "" ; Write-Host "Script terminated without deleting the VHD file." ; "" } } $true { ## Confirmation prompt suppressed ## Remove-Item -Path $Path -Force "" ; Write-Host "VHD ""$Path"" deleted!" ; "" } } } ## Validate Operating System Version ## if (Get-WmiObject win32_OperatingSystem -Filter "Version < '6.1'") {throw "The script operation requires at least Windows 7 or Windows Server 2008 R2."} } process{ ## DiskPart Script Content ## Here-String statement purposefully not indented ## @" $(if ($Rescan) {'Rescan'}) Select VDisk File="$Path"`nDetach VDisk Exit "@ | Out-File -FilePath $DiskpartScript -Encoding ASCII -Force InvokeDiskpart Start-Sleep -Seconds 10 } end { if ($Remove) {RemoveVHD} Remove-Item -Path $DiskpartScript -Force ; "" } }

    Read the article

  • windows 7 no internet access

    - by Kyle
    Just did a fresh install of Windows 7, and the network and sharing center says no internet access. Disabling and enabling the adapter seems to fix the issue temporarily, but the internet stops working shortly after. I have installed the latest NIC drivers and have installed all Windows updates. I have also tried manually setting the ip/gateway/dns and running netsh int ip reset in an elevated command prompt. I am running Windows 7 Home Premium 64bit with a wired connection. I have searched for hours, but have found no working solutions. Does anyone have any ideas?

    Read the article

  • How important are PTR records for Email Servers?

    - by Kyle Brandt
    Does anyone know of any studies done to show how much email will be rejected if there is not ptr record for the SMTP banner name of an email server? Are reverse checks always done when enabled, or is it sometimes configured so if an spam program considers an email 'iffy', the reverse check is done?

    Read the article

  • IP addresses for Windows Azure servers seem to be from the US, when the servers are supposed to be located in Europe

    - by paradroid
    I have a couple of test servers on Windows Azure. One is in the North Europe location and the other is in West Europe. I yet to get around to testing which location offers better connection speeds from where I am (London, UK). The Northern Europe Azure datacentre is apparently in Ireland and the West Europe datacentre is in the Netherlands, which is weird in itself I think. But what I am confused about are the IP addresses are both 168.63.xxx.xxx. GeoIP lookup says that they are both located in the US, and traceroute from London to the addresses get to the US before failing to respond pings. What's going on?

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here. EDIT: I found another person who has the exact same problem as me: http://www.ibm.com/developerworks/forums/thread.jspa?messageID=14451763

    Read the article

  • How does Subnetting Work?

    - by Kyle Brandt
    How does Subnetting Work, and How do you do it by hand or in your head? Can someone explain both conceptually and with several examples? Server Fault gets lots of subnetting homework questions, so we could use an answer to point them to on Server Fault itself. What is classless routing and why is class-based routing obsolete? If I have a network, how do I figure out how to split it up? If I am given a netmask, how do I know what the network Range is for it? Sometimes there is a slash followed by a number, what is that number? Sometimes there is a subnet mask, but also a wildcard mask, they seem like the same thing but they are different? Someone mentioned something about knowing binary for this? Not looking for links to other sites (unless maybe you have one post with a bunch of good ones). I already know how to subnet, I just thought it would be nice if Server Fault had a generic subnetting answer.

    Read the article

  • Backing up my data causes my server to crash using Symantec Backup Exec 12, or How I Came to Loathe

    - by Kyle Noland
    I have a Dell PowerEdge 2850 running Windows Server 2003. It is the primary file server for one of my clients. I have another server also running Windows Server 2003 that acts as the core media server for Symantec Backup Exec 12. I recently upgraded from Backup Exec 11d to 12. This upgrade was necessary because we also just upgraded from Exchange 2003 to Exchange 2007. After the upgrade I had to push-install the new version 12 Backup Exec Remote Agents to each of the servers I am backing up (about 6 total). 5 of my servers are doing just fine, faithfully completing backups every night. My file server routinely crashes. Observations: When the server crashes, it does not blue screen, it just locks up completely. Even the mouse is unresponsive. If you leave the server locked up long enough, it will eventually reboot itself and hang on the Windows splash screen. There is absolutely zero useful Event Viewer evidence of a problem. The logs go from routine logging to an Unexplained Shutdown Event the next morning when I have to hard reset the server to get it to boot. 90% of the time the server does not boot cleanly, it hangs on the Windows splash screen. I don't have any light to shed here. When the server hangs all I can do is hard reset it and try again. Even after a successful boot and chkdsk /r operation, if you reboot the machine, you have a 90% chance it won't back up again cleanly. The back story: This server started crashing during nightly backups about a month ago. I tried everything I could think of to troubleshoot the problem and eventually had to give up because I could not keep coming to the office at 4 AM to try to get the server back online. One Friday I got lucky and the server stayed up for its entire full backup. I took this opportunity to restore the full backup to a temporary server I set up and switched all my users to the temporary. Then I reloaded the ailing file server. I kept all my users on the temporary file server for about 3 weeks. I installed the same Backup Exec Remote Agent and Trend Micro A/V client on the temporary server that I was using on the regular file server. During this time, I had absolutely no problems backing up the temporary server. I tested the reloaded file server extensively. I rebooted the server once an hour every day for 3 weeks trying to make it fail. It never did. I felt confident that the reload was the answer to my problems. I moved all of the data from the temporary server back to the regular server. I got 3 nightly backups out of it before it locked up again and started the familiar failure to boot cleanly behavior. This weekend I decided to monitor the file server through the entire backup job. I RDPd into the file server and also into the server running Backup Exec. On the file server I opened the Task Manager so I could view the processes and watch CPU and memory usage. Everything was running smoothly for about 60GB worth of backup. Then I noticed that the byte count of the backup job in Backup Exec had stopped progressing. I looked back over at my RDP session into the file server, and I was getting real time updates about CPU and memory usage still - both nearly 0%, which is unusual. Backups usually hover around 40% usage for the duration of the backup job. Let me reiterate this point: The screen was refreshing and I was getting real time Task Manager updates - until I clicked on the Start menu. The screen went black and the server locked up. In truth, I think the server had already locked up, the video card just hadn't figured it out yet. I went back into my bag of trick: driving to the office and hard reseting the server over and over again when it hangs up at the Windows splash screen. I did this for 2 hours without getting a successful boot. I started panicking because I did not have a decent backup to use to get everything back onto the working temporary file server. Once I exhausted everything I knew to do, I took a deep breath, booted to the Windows Server 2003 CD and performed a repair installation of Windows. The server came back up fine, with all of my data intact. I can now reboot the server at will and it will come back up cleanly. The problem is that I'm afraid as soon as I try to back that data up again I will back at square one. So let me sum things up: Here is what I've done so far to troubleshoot this server: Deleted and recreated the RAID 5 sets. Initialized the drives. Reloaded the server with a fresh Server 2003 install. Confirmed with Dell that I have installed the latest, Dell approved BIOS and NIC drivers. Uninstalled / reinstalled the Backup Exec Remote Agent. Uninstalled the Trend Micro A/V client. Configured the server not to reboot itself after a blue screen so I can see any stop error. I used to think the server was blue screening, but since I enabled this setting I now know that the server just completely locks up. Run chkdsk /r from the Windows Recovery Console. Several errors were found and corrected, but did not help my problem. Help confirm or deny the following assumptions: There are two problems at work here. Why the server is locking up in the first place, and why the server won't boot cleanly after a lockup. This is ultimately a software problem. The server works fine and can be rebooted cleanly all day long - until the first lockup - following a fresh OS load or even a Repair installation. This is not a problem with Backup Exec in general. All of my other servers back up just fine. For the record, all of the other servers run Server 2003, and some of them house more data than the file server in question here. Any help is appreciated. The irony is almost too much to bear. Backing up my data is what is jeopardizing it.

    Read the article

  • CPU Limits for Application Pools in IIS 7.5

    - by Kyle Brandt
    I see that in iis 7.5 I can set a CPU % utilization limit for a specified amount of time for an application pool. I can have also have it kill the worker process if this limit is violated. If tell it to do this, will the worker process automatically restart after it is killed, or is manual intervention required? Over at Stack Overflow there is the mention that it can restarted at the completion of the interval...

    Read the article

  • Ironport X-Junk header.

    - by Kyle
    My school uses Ironport for filtering/monitoring web traffic. I have a bit of curiosity as to why it tacks on a x-junk: header onto everything. After going through a few curl tests, I've found no real connection between what is shown on the page and the x-junk: header. here's my curl request: any ideas? Anchorage:~ khotchkiss$ curl -I google.com HTTP/1.1 301 Moved Permanently Location: http://www.google.com/ Content-Type: text/html; charset=UTF-8 Date: Sun, 06 Feb 2011 04:37:25 GMT Expires: Tue, 08 Mar 2011 04:37:25 GMT Cache-Control: public, max-age=2592000 Server: gws X-XSS-Protection: 1; mode=block Content-Length: 219 Age: 108 Via: 1.1 MC-IRONPORT.UNIVERSITY.LIBERTY.EDU:80 (IronPort-WSA/6.3.3-015) Connection: keep-alive X-Junk: xxxxxxxxxxxxxxxxxxxxxxx

    Read the article

  • WHS - Windows Update Failure

    - by Kyle B.
    Clicking "Update Now..." inside my EX470 control panel for Windows Update produces the following error message: "Windows Home Server updates installation can not complete. Please try again later. If the problem persists, please restart the server." I have rebooted the server numerous times, and I have also used remote desktop to connect to the machine to perform the update this way, however the browser is unable to pull up http://windowsupdate.microsoft.com. This is very strange behavior because I am able to access all other sites (gmail.com, serverfault.com, etc). Would it be possible for someone to explain to me how I can check to see what is blocking the connection of this device, which apparently has a valid internet connection, to the Microsoft Windows Update site? note #1 Using the shortcut: %SystemRoot%\system32\wupdmgr.exe does not work either. It says "Connecting to 65.55.200.155..." but nothing ever happens. This is strange because all other sites seem fine. Also, I can connect to windowsupdate.microsoft.com on my local desktop so I know this is running as well

    Read the article

  • Running Job and Paused Job Writing to the same File

    - by Kyle Brandt
    So I ran tcpdump twice overnight by accident, both outputting to the same file. However, I ran them as jobs and one of them has been paused the whole time. Anyone have a recommendations on how to keep the file? So far I have thought of: kill -9 the paused job Pause the running job, copy the file, and then stop both. Two sounds like the safest option, anyone have a better idea other than not doing this in the first place ;-)

    Read the article

  • My -tpl file won't update!

    - by Kyle Sevenoaks
    Hi, I am running the site at www.euroworker.no, it's a linux server and the site has a backend editor. It's a smarty/php site, and when I try to update a few of the .tpl's (two or three) they don't update. I have tried uploading through FTP and that doesn't work either. I have no knowledge of how servers work or anything, please help? It runs on the livecart system. Thanks!

    Read the article

  • My -tpl file won't update!

    - by Kyle Sevenoaks
    Hi, I am running the site at www.euroworker.no, it's a linux server and the site has a backend editor. It's a smarty/php site, and when I try to update a few of the .tpl's (two or three) they don't update. I have tried uploading through FTP and that doesn't work either. I have no knowledge of how servers work or anything, please help? It runs on the livecart system. Thanks!

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • tcpdump filter that excludes private ip traffic

    - by Kyle Brandt
    For a generic filter to exclude all traffic in my dump that is between private IP address, I came up with the following: sudo tcpdump -n ' (not ( (src net 172.16.0.0/20 or src net 10.0.0.0/8 or src net 192.168.0.0/16) and (dst net 172.16.0.0/20 or dst net 10.0.0.0/8 or dst net 192.168.0.0/16) ) ) and (not ( (dst net 172.16.0.0/20 or dst net 10.0.0.0/8 or dst net 192.168.0.0/16) and (src net 172.16.0.0/20 or src net 10.0.0.0/8 or src net 192.168.0.0/16) ) )' -w test2.dump Seems pretty excessive, but it also seems to work, is this filter a lot longer than it needs to be and there is better way to express this logic, or is there anything wrong with the filter?

    Read the article

  • Using NTBackup to Backup Exchange 2003 Mail Stores

    - by Kyle Brandt
    I have netbackup backing up my Exchange stores stores to tape, but would like to maybe make the restore process faster. I have plenty of room on the array attached to the mail server, so I was thinking I could use NTBackup to do weekly backups in addition to my tape backups. Has anyone used this with good success?

    Read the article

  • Disable laptop screen

    - by Kyle
    I recently had the display fail on my Dell Inspiron E1505 laptop. I currently have my TV hooked up to the laptop's S-Video out which works fine as long as I'm running in Windows. For the first minute or so when the computer is booting I get no display. I was wondering if there was any way to disable the laptop screen entirely so that the TV display is active from the beginning (not just after Windows loads). I realize there may be a BIOS setting for this, my only problem is I can't see the BIOS settings screen since no display is active at that point so if anyone has any BIOS setting solutions I'd need the exact keystrokes to hit :)

    Read the article

  • PostgreSQL has no service name on CentOS

    - by Kyle MacFarlane
    I installed PostgreSQL in a pretty standard way on CentOS 5.5: rpm -ivh http://yum.pgrpms.org/reporpms/9.0/pgdg-centos-9.0-2.noarch.rpm yum install postgresql90-server postgresql90-contrib chkconfig postgresql-90 on /etc/init.d/postgresql-90 initdb But for some reason I can't use it with the service command because it has no name, .e.g if I do service --status-all I get back the following: master (pid 3095) is running... (pid 3009) is running... rdisc is stopped Or even just /etc/init.d/postgresql-90 status: (pid 3009) is running... So how can I give it a name so that I don't have to type out the whole init script path each time?

    Read the article

  • How can I prevent static when PC is plugged into an amplified speaker system?

    - by Kyle
    I've plugged a computer into an amp, using a 1/8 inch male extension cord, into a female adapter, that adapts into a male microphone 1/4 end. That being said, the amp sits at about half volume all the time because there are other things that play on it. (This issue is not flexible, nor is changing the amp) The problem is that now, even when I mute out the computer, you hear some static in the background. I was wondering some about some solutions (preferably multiple).

    Read the article

< Previous Page | 14 15 16 17 18 19 20 21 22 23 24 25  | Next Page >