Search Results

Search found 23762 results on 951 pages for 'network speed'.

Page 189/951 | < Previous Page | 185 186 187 188 189 190 191 192 193 194 195 196  | Next Page >

  • How do I connect to my home's primary wired network through an extra (wireless) router?

    - by Matthew Patrick Cashatt
    Thanks for looking! I have set up a desktop PC in my workshop. The Cat 5 cable connects from this PC to a wireless router which is connected to my home network. The Internet connection is working just fine. However, the "wired" network this is on shows up as a different wired network than the one that the PCs inside my house are connected to. This is a problem because I would like to connect this workshop PC to various shared resources like printers, HD Homerun (cable tv card), shared drives, etc. When I go to "Network and Sharing" and attempt to find the network that the PCs inside my home are connected to, I don't see it. Any help is appreciated. Thanks!

    Read the article

  • How to build a private Wi-Fi Network server with VMware?

    - by Maarten Schermer
    For a school project, we have to build a Private network with VMware vSphere , which we can connect to with a Username and Password. On the network we want to create a folder for each Useraccount. Also we must have add a few groups (Admin,Customer,Manager). We must be able to connect to our network via the school Wi-Fi. We want to build a safe and secure network, with an easy way to access the network. Do you have any tips on how to approach this?

    Read the article

  • How to set the network profile of Windows 7 via group policy?

    - by Ricket
    We are deploying client computers and in testing noticed that the first time the user logs into the computer, it asks them if the location is a home, work, or public location. We are worried that some users in our workplace might misread it (or not read it at all) and click Public, thus likely denying our access to the computer and messing up security settings and such. Can we set our network to be a "Work Network" location via group policy or some other mechanism of our Windows Domain so that the user is not prompted when connected to our network? Also these are laptops, so we don't want every network they connect to be set as work network, and we have several access points (wired and three wireless) which our users often switch between so I'm not yet sure if it reprompts with each access point but I have the feeling it will, and I would like all of these to be set to the Work profile type.

    Read the article

  • Ubuntu: On a network with many clients there are two machines that can't access the web via a browser at the same time

    - by ChrisInCambo
    Ok I'm pulling my hair out over this one. We have a wireless network with many clients all working well except two Ubuntu clients running 10.10 that can't access the internet via a browser at the same time. They can both still ping, use Skype etc but can't browse. As soon as the one that can browse exits the network browsing returns for the other and vice versa. As ping and Skype was working I assumed some kind of DNS problem but moving over to OpenDNS didn't solve it, nor did restarting networking or using wired rather than wireless. We also switched out the router, and it still persisted so I'm sure this isn't a network issue. The two clients are both laptops and work fine together on a wireless network at another office (which we don't control). I'm thinking something must be cached from the other network they both use that's causing this but have no idea what. Does anyone have any ideas? I just don't know where to go from here.

    Read the article

  • Unity JS - simple if statements not behaving as expected?

    - by IHazABone
    I have a simple script (please no remarks on the fact that I'm not using a switch statement or better code, this is the earliest version and written this way by a peer, I am improving it) that takes an object and moves it back and forth. For some reason, the variable time gets stuck at 249. It is probably an obvious bug with this inefficient logic, but I cannot seem to find it. var speed = 1; private var time = 0; function Start() { } function Update() { if(condition == true)moveStuff(); } function moveStuff() { var timeSwitch = false; if(time == 0)timeSwitch = false; if(time == timeSet)timeSwitch = true; if(direction == 1) { if(timeSwitch == false) { transform.Translate(Vector3.up * (Time.deltaTime * speed)); time += 1; Debug.Log(time); }else if(timeSwitch == true) { transform.Translate(Vector3.up * ((Time.deltaTime * speed) * -1)); time -= 1; Debug.Log(time); } } else if(direction == 2) { if(timeSwitch == false) { transform.Translate(Vector3.down * (Time.deltaTime * speed)); time += 1; Debug.Log("Moved down. "); }else if(timeSwitch == true){ transform.Translate(Vector3.down * ((Time.deltaTime * speed) * -1)); time -= 1; } } else if(direction == 3) { if(timeSwitch == false) { transform.Translate(Vector3.forward * (Time.deltaTime * speed)); time += 1; Debug.Log("Moved forward. "); }else if(timeSwitch == true){ transform.Translate(Vector3.forward * ((Time.deltaTime * speed) * -1)); time -= 1; } } else if(direction == 4) { if(timeSwitch == false) { transform.Translate(Vector3.back * (Time.deltaTime * speed)); time += 1; Debug.Log("Moved back. "); }else if(timeSwitch == true){ transform.Translate(Vector3.back * ((Time.deltaTime * speed) * -1)); time -= 1; } } else if(direction == 5) { if(timeSwitch == false) { transform.Translate(Vector3.right * (Time.deltaTime * speed)); time += 1; Debug.Log("Moved right. "); }else if(timeSwitch == true){ transform.Translate(Vector3.right * ((Time.deltaTime * speed) * -1)); time -= 1; } } else if(direction == 6) { if(timeSwitch == false) { transform.Translate(Vector3.left * (Time.deltaTime * speed)); time += 1; Debug.Log("Moved left. "); }else if(timeSwitch == true){ transform.Translate(Vector3.left * ((Time.deltaTime * speed) * -1)); time -= 1; } } }

    Read the article

  • Cause of slow download speed on a particular EC2 instance?

    - by James
    I have a networking issue I'm trying to solve. I have two EC2 instances, same zone, same type. On one of the two EC2 instances (the 'bad' instance), the download speed is really poor (200k/s), while on the other (the 'good' instance), the download speed is fine, comfortable at 30M/s +). To clarify, I'm talking about downloading files to the EC2 instance while ssh'd into the server, e.g running wget with a large file. I've tried different files, including S3 objects and a large linux ISO from elsewhere. Running ethtool eth0 only returns 'Link detected: yes' for both. When running ifconfig, both return the same for most part, aside from how the good instance shows no error packets yet the bad instance shows many: UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:168372370 errors:5075643 dropped:0 overruns:0 frame:0 TX packets:122116480 errors:0 dropped:0 overruns:0 carrier:0 Both servers are configured the same, at least were supposed to be. How can I go about diagnosing the cause for the slow download speed? Is there anything particular to EC2 instances that could cause this? Having trouble knowing where to start. Thanks for any help!

    Read the article

  • Collect temperature and fan speed with munin from Windows 7 PC?

    - by mfn
    Hi, I'm quite fond of munin and using it also at home to monitor my PCs. What was super-duper easy under Linux is pretty much unsolvable for me under Windows: I'd like to monitor CPU and Motherboard temperatures as well as fan speed. On Linux I'm using lm-sensors and the plugin for munin was basically there. I access already some information from my Windows machine via SNMP (disk space, CPU usage, memory usage); the graphs are simple as is the information exposed via SNMP, but they do their job. But when it comes to temperature and fan speed I'm running against a wall. My research so far resulted in that Windows does not by default provide out of the box ability to retrieve temperature/fan speed data. Third party applications are necessary which have know-how how to communicate with the Motherboard chips. The best I cam up with is that SpeedFan exposes a shared memory interface and there exists a library which hooks into Windows SNMP facility and bridges over to SpeedFans shared memory interface; it's called SFSNMP (site currently down). Unfortunately the library doesn't work, there's a bug report at SpeedFan open about it, but it's currently not moving (although the SFSNMP author is active there) . So, unless that's going to work like anytime soon, are there any alternatives? I'm not found of buying any software to get that feature, given that I take it as granted that my system exposes me the information to properly monitor it, but anyway don't just not answer because of this.

    Read the article

  • How to increase the speed between two external hard drives on my laptop?

    - by Roman
    Hello, I own Sony Vaio Z laptop with two external USB ports. It's quite new and has USB 2.0 support. I'm using Vista x64 on it. I also have two external usb hard drives, Iomega 500GB and WD for 1TB. Every hard drive has USB 2.0 support. I connect two devices to my laptop and trying to copy date from one hard drive to another. But it takes a lot of time! The speed is about 15 Megabytes per second. I have to wait toooooo long to copy all the information from one hard drive to another. When I try to copy information from my internal (SSD) hard drive, it works fine for both external drives. The speed is very high and it shows me something about 100 Megabytes per second. It makes me feel that USB 2.0 is OK on both drives. But when I'm trying to copy from one external drive to another external, I still get very low speed. I checked out Device Manager and here is the settings I have: (sorry, can't upload image because of my rating, check this url: http://picbite.com/image/122073daljo/ ) I think it's because two of my external drives use the same USB 2.0 controller. Is there any way to make it work faster? Is it possible to move one of my USB ports to other USB 2.0 controller? Or is there any software which can help me to automate copying all the files thru my internal drive? I have only about 3 gigabytes free space on internal drive and it's quite difficult to move manually every file from one hard drive to internal and then again to another internal.

    Read the article

  • How to increase the speed between two external hard drives on my laptop?

    - by Roman
    Hello, I own Sony Vaio Z laptop with two external USB ports. It's quite new and has USB 2.0 support. I'm using Vista x64 on it. I also have two external usb hard drives, Iomega 500GB and WD for 1TB. Every hard drive has USB 2.0 support. I connect two devices to my laptop and trying to copy date from one hard drive to another. But it takes a lot of time! The speed is about 15 Megabytes per second. I have to wait toooooo long to copy all the information from one hard drive to another. When I try to copy information from my internal (SSD) hard drive, it works fine for both external drives. The speed is very high and it shows me something about 100 Megabytes per second. It makes me feel that USB 2.0 is OK on both drives. But when I'm trying to copy from one external drive to another external, I still get very low speed. I checked out Device Manager and here is the settings I have: (sorry, can't upload image because of my rating, check this url: http://picbite.com/image/122073daljo/ ) I think it's because two of my external drives use the same USB 2.0 controller. Is there any way to make it work faster? Is it possible to move one of my USB ports to other USB 2.0 controller? Or is there any software which can help me to automate copying all the files thru my internal drive? I have only about 3 gigabytes free space on internal drive and it's quite difficult to move manually every file from one hard drive to internal and then again to another internal.

    Read the article

  • Collect temperature and fan speed with munin from Windows 7 PC?

    - by nfm
    Hi, I'm quite fond of munin and using it also at home to monitor my PCs. What was super-duper easy under Linux is pretty much unsolvable for me under Windows: I'd like to monitor CPU and Motherboard temperatures as well as fan speed. On Linux I'm using lm-sensors and the plugin for munin was basically there. I access already some information from my Windows machine via SNMP (disk space, CPU usage, memory usage); the graphs are simple as is the information exposed via SNMP, but they do their job. But when it comes to temperature and fan speed I'm running against a wall. My research so far resulted in that Windows does not by default provide out of the box ability to retrieve temperature/fan speed data. Third party applications are necessary which have know-how how to communicate with the Motherboard chips. The best I cam up with is that SpeedFan exposes a shared memory interface and there exists a library which hooks into Windows SNMP facility and bridges over to SpeedFans shared memory interface; it's called SFSNMP (site currently down). Unfortunately the library doesn't work, there's a bug report at SpeedFan open about it, but it's currently not moving (although the SFSNMP author is active there) . So, unless that's going to work like anytime soon, are there any alternatives? I'm not found of buying any software to get that feature, given that I take it as granted that my system exposes me the information to properly monitor it, but anyway don't just not answer because of this.

    Read the article

  • vmware server 64 bit on ubuntu 9.10 64 bit with P2V windows 2003 SBS poor network speed

    - by RobertHC
    configuration is ubuntu 2.6.31-21 64 bit vmware 2.0.2 64 bit last release hardware is core 2 quad with 8GB ram guest is win 2003 server SBS 32 bit Dear friends, we have a converted physical to virtual windows sbs 2003, converted with last converter available nowadays http://www.vmware.com/products/converter/ vCenter converter. Running the P2V 2K3 SBS on vmware server, it does boot fine, but we do note an abnormal CPU activity and a poor lan speed. As attempts we did what follow. We removed all unneeded peripherals, we removed one NIC (phisycal server was 2 nics), we changed the vmx to ged the nic recognized as intel instead than amd, we removed 1 cpu (physical was 2 cpu), we removed anything was reported as failed driver from system events monitor. Nothing to do, no way and funny results. Let's read some tests results. All are made with the same file copied in different source folders. Copying from client side (both directions copy, to/from server) results are i.e. 10 seconds, copying the same files from server side (again from and to server) results are different... from client to server, speed is round about (bit more) 10 seconds, but from server to client direction is slower: double the time. Beeing very fast and launching a simultaneous copy "from server to client"+"from client to server", this made from the server side, results in a stuck traffic... 45 seconds to do the copy. vmware tools are installed and e1000 driver has been updated. With one processor CPU activity is still going up and down but much less than with two. Because of test, we installed win 2k8 STD 64 bit. We repeated all the above tests with exactly the same file result is just one: always 5 seconds (this matches the lan speed) Any idea about this issue is welcome and thank you if any. Kind regards R.

    Read the article

  • WCF net.tcp windows service - call duration and calls outstanding increases over time

    - by Brook
    I have a windows service which uses the ServiceHost class to host a WCF Service using the net.tcp binding. I have done some tweaking to the config to throttle sessions as well as number of connections, but it seems that every once in a while my "Calls outstanding" and "Call duration" shoot up and stay up in perfmon. It seems to me I have a leak somewhere, but the code I have is all fairly minimal, I'm relying on ServiceHost to handle the details. Here's how I start my service ServiceHost host = new ServiceHost(type); host.Faulted+=new EventHandler(Faulted); host.Open(); My Faulted event just does the following (more or less, logging etc removed) if (host.State == CommunicationState.Faulted) { host.Abort(); } else { host.Close(); } host = new ServiceHost(type); host.Faulted+=new EventHandler(Faulted); host.Open(); Here's some snippets from my app.config to show some of the things I've tried <runtime> <gcConcurrent enabled="true" /> <generatePublisherEvidence enabled="false" /> </runtime> ......... <behaviors> <serviceBehaviors> <behavior name="Throttled"> <serviceThrottling maxConcurrentCalls="300" maxConcurrentSessions="300" maxConcurrentInstances="300" /> .......... <services> <service name="MyService" behaviorConfiguration="Throttled"> <endpoint address="net.tcp://localhost:49001/MyService" binding="netTcpBinding" bindingConfiguration="Tcp" contract="IMyService"> </endpoint> </service> </services> .......... <netTcpBinding> <binding name="Tcp" openTimeout="00:00:10" closeTimeout="00:00:10" portSharingEnabled="true" receiveTimeout="00:5:00" sendTimeout="00:5:00" hostNameComparisonMode="WeakWildcard" listenBacklog="1000" maxConnections="1000"> <reliableSession enabled="false"/> <security mode="None"/> </binding> </netTcpBinding> .......... <!--for my diagnostics--> <diagnostics performanceCounters="ServiceOnly" wmiProviderEnabled="true" /> There's obviously some resource getting tied up, but I thought I covered everything with my config. I'm only getting about ~150 clients so I don't think I'm coming up against my "300" limit. "Calls per second" stays constant at anywhere from 2-5 calls per second. The service will run for hours and hours with 0-2 "calls outstanding" and very low "call duration" and then eventually it will shoot up to 30 calls oustanding and 20s call duration. Any tips on what might be causing my "calls outstanding" and "call duration" to spike? Where am I leaking? Point me in the right direction?

    Read the article

  • Windows 7 - Enable Network DTC Access

    - by Russ Clark
    I have a Visual Studio 2010 Windows Forms application in which I start a transaction using the TransactionScope class. I then Receive a message from a Sql Server Broker Services message queue, which works fine. I next try to call a stored procedure from the same database with a call to my data access layer which is a Visual Studio dataset (xsd file). When I make this second call to the database I get the following error message: The MSDTC transaction manager was unable to pull the transaction from the source transaction manager due to communication problems. Possible causes are: a firewall is present and it doesn't have an exception for the MSDTC process, the two machines cannot find each other by their NetBIOS names, or the support for network transactions is not enabled for one of the two transaction managers. (Exception from HRESULT: 0x8004D02B). I've seen several posts on the web that talk about Enabling DTC access through dcomcnfg.exe, and allowing DTC to communicate through Windows Firewall. I've done those things, and am still having this problem. I know our remote database server is setup to Enable DTC access, because we are using similar transactions in other projects built with Visual Studio 2008 on Windows XP and Vista. I think there is something specific about Windows 7 and Visual Studio 2010 causing this problem, but haven't been able to find out what it is. Can anyone help with this problem?

    Read the article

  • requestRouteToHost android

    - by Sam
    Greetings everyone! I'm getting rather fed up with android's ConnectivityManager class. I've been trying for 5 hours to get the requestRouteToHost to work. I'm running my code on the emulator but the requestRouteToHost always fails. I know I have connectivity because I called getActiveNetworkInfo() and it was connected. I've added the ACCESS_NETWORK_STATE and CHANGE_NETWORK_STATE permissions to no avail. Any tips would be greatly appreciated. Sam

    Read the article

  • Reinforcement learning in C#

    - by Betamoo
    I intend to use Reinforcement learning in my project but I do not know much how to implement it.. So I am looking for a library with different RL algorithms that I can use in my C# project.. Thanks Please Note: I found NeuronDotNet library for neural networks, I am now looking for RL library..

    Read the article

  • SQL SERVER – Guest Posts – Feodor Georgiev – The Context of Our Database Environment – Going Beyond the Internal SQL Server Waits – Wait Type – Day 21 of 28

    - by pinaldave
    This guest post is submitted by Feodor. Feodor Georgiev is a SQL Server database specialist with extensive experience of thinking both within and outside the box. He has wide experience of different systems and solutions in the fields of architecture, scalability, performance, etc. Feodor has experience with SQL Server 2000 and later versions, and is certified in SQL Server 2008. In this article Feodor explains the server-client-server process, and concentrated on the mutual waits between client and SQL Server. This is essential in grasping the concept of waits in a ‘global’ application plan. Recently I was asked to write a blog post about the wait statistics in SQL Server and since I had been thinking about writing it for quite some time now, here it is. It is a wide-spread idea that the wait statistics in SQL Server will tell you everything about your performance. Well, almost. Or should I say – barely. The reason for this is that SQL Server is always a part of a bigger system – there are always other players in the game: whether it is a client application, web service, any other kind of data import/export process and so on. In short, the SQL Server surroundings look like this: This means that SQL Server, aside from its internal waits, also depends on external waits and settings. As we can see in the picture above, SQL Server needs to have an interface in order to communicate with the surrounding clients over the network. For this communication, SQL Server uses protocol interfaces. I will not go into detail about which protocols are best, but you can read this article. Also, review the information about the TDS (Tabular data stream). As we all know, our system is only as fast as its slowest component. This means that when we look at our environment as a whole, the SQL Server might be a victim of external pressure, no matter how well we have tuned our database server performance. Let’s dive into an example: let’s say that we have a web server, hosting a web application which is using data from our SQL Server, hosted on another server. The network card of the web server for some reason is malfunctioning (think of a hardware failure, driver failure, or just improper setup) and does not send/receive data faster than 10Mbs. On the other end, our SQL Server will not be able to send/receive data at a faster rate either. This means that the application users will notify the support team and will say: “My data is coming very slow.” Now, let’s move on to a bit more exciting example: imagine that there is a similar setup as the example above – one web server and one database server, and the application is not using any stored procedure calls, but instead for every user request the application is sending 80kb query over the network to the SQL Server. (I really thought this does not happen in real life until I saw it one day.) So, what happens in this case? To make things worse, let’s say that the 80kb query text is submitted from the application to the SQL Server at least 100 times per minute, and as often as 300 times per minute in peak times. Here is what happens: in order for this query to reach the SQL Server, it will have to be broken into a of number network packets (according to the packet size settings) – and will travel over the network. On the other side, our SQL Server network card will receive the packets, will pass them to our network layer, the packets will get assembled, and eventually SQL Server will start processing the query – parsing, allegorizing, generating the query execution plan and so on. So far, we have already had a serious network overhead by waiting for the packets to reach our Database Engine. There will certainly be some processing overhead – until the database engine deals with the 80kb query and its 20 subqueries. The waits you see in the DMVs are actually collected from the point the query reaches the SQL Server and the packets are assembled. Let’s say that our query is processed and it finally returns 15000 rows. These rows have a certain size as well, depending on the data types returned. This means that the data will have converted to packages (depending on the network size package settings) and will have to reach the application server. There will also be waits, however, this time you will be able to see a wait type in the DMVs called ASYNC_NETWORK_IO. What this wait type indicates is that the client is not consuming the data fast enough and the network buffers are filling up. Recently Pinal Dave posted a blog on Client Statistics. What Client Statistics does is captures the physical flow characteristics of the query between the client(Management Studio, in this case) and the server and back to the client. As you see in the image, there are three categories: Query Profile Statistics, Network Statistics and Time Statistics. Number of server roundtrips–a roundtrip consists of a request sent to the server and a reply from the server to the client. For example, if your query has three select statements, and they are separated by ‘GO’ command, then there will be three different roundtrips. TDS Packets sent from the client – TDS (tabular data stream) is the language which SQL Server speaks, and in order for applications to communicate with SQL Server, they need to pack the requests in TDS packets. TDS Packets sent from the client is the number of packets sent from the client; in case the request is large, then it may need more buffers, and eventually might even need more server roundtrips. TDS packets received from server –is the TDS packets sent by the server to the client during the query execution. Bytes sent from client – is the volume of the data set to our SQL Server, measured in bytes; i.e. how big of a query we have sent to the SQL Server. This is why it is best to use stored procedures, since the reusable code (which already exists as an object in the SQL Server) will only be called as a name of procedure + parameters, and this will minimize the network pressure. Bytes received from server – is the amount of data the SQL Server has sent to the client, measured in bytes. Depending on the number of rows and the datatypes involved, this number will vary. But still, think about the network load when you request data from SQL Server. Client processing time – is the amount of time spent in milliseconds between the first received response packet and the last received response packet by the client. Wait time on server replies – is the time in milliseconds between the last request packet which left the client and the first response packet which came back from the server to the client. Total execution time – is the sum of client processing time and wait time on server replies (the SQL Server internal processing time) Here is an illustration of the Client-server communication model which should help you understand the mutual waits in a client-server environment. Keep in mind that a query with a large ‘wait time on server replies’ means the server took a long time to produce the very first row. This is usual on queries that have operators that need the entire sub-query to evaluate before they proceed (for example, sort and top operators). However, a query with a very short ‘wait time on server replies’ means that the query was able to return the first row fast. However a long ‘client processing time’ does not necessarily imply the client spent a lot of time processing and the server was blocked waiting on the client. It can simply mean that the server continued to return rows from the result and this is how long it took until the very last row was returned. The bottom line is that developers and DBAs should work together and think carefully of the resource utilization in the client-server environment. From experience I can say that so far I have seen only cases when the application developers and the Database developers are on their own and do not ask questions about the other party’s world. I would recommend using the Client Statistics tool during new development to track the performance of the queries, and also to find a synchronous way of utilizing resources between the client – server – client. Here is another example: think about similar setup as above, but add another server to the game. Let’s say that we keep our media on a separate server, and together with the data from our SQL Server we need to display some images on the webpage requested by our user. No matter how simple or complicated the logic to get the images is, if the images are 500kb each our users will get the page slowly and they will still think that there is something wrong with our data. Anyway, I don’t mean to get carried away too far from SQL Server. Instead, what I would like to say is that DBAs should also be aware of ‘the big picture’. I wrote a blog post a while back on this topic, and if you are interested, you can read it here about the big picture. And finally, here are some guidelines for monitoring the network performance and improving it: Run a trace and outline all queries that return more than 1000 rows (in Profiler you can actually filter and sort the captured trace by number of returned rows). This is not a set number; it is more of a guideline. The general thought is that no application user can consume that many rows at once. Ask yourself and your fellow-developers: ‘why?’. Monitor your network counters in Perfmon: Network Interface:Output queue length, Redirector:Network errors/sec, TCPv4: Segments retransmitted/sec and so on. Make sure to establish a good friendship with your network administrator (buy them coffee, for example J ) and get into a conversation about the network settings. Have them explain to you how the network cards are setup – are they standalone, are they ‘teamed’, what are the settings – full duplex and so on. Find some time to read a bit about networking. In this short blog post I hope I have turned your attention to ‘the big picture’ and the fact that there are other factors affecting our SQL Server, aside from its internal workings. As a further reading I would still highly recommend the Wait Stats series on this blog, also I would recommend you have the coffee break conversation with your network admin as soon as possible. This guest post is written by Feodor Georgiev. Read all the post in the Wait Types and Queue series. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, Readers Contribution, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, SQL Wait Stats, SQL Wait Types, T SQL

    Read the article

  • What's up with LDoms: Part 4 - Virtual Networking Explained

    - by Stefan Hinker
    I'm back from my summer break (and some pressing business that kept me away from this), ready to continue with Oracle VM Server for SPARC ;-) In this article, we'll have a closer look at virtual networking.  Basic connectivity as we've seen it in the first, simple example, is easy enough.  But there are numerous options for the virtual switches and virtual network ports, which we will discuss in more detail now.   In this section, we will concentrate on virtual networking - the capabilities of virtual switches and virtual network ports - only.  Other options involving hardware assignment or redundancy will be covered in separate sections later on. There are two basic components involved in virtual networking for LDoms: Virtual switches and virtual network devices.  The virtual switch should be seen just like a real ethernet switch.  It "runs" in the service domain and moves ethernet packets back and forth.  A virtual network device is plumbed in the guest domain.  It corresponds to a physical network device in the real world.  There, you'd be plugging a cable into the network port, and plug the other end of that cable into a switch.  In the virtual world, you do the same:  You create a virtual network device for your guest and connect it to a virtual switch in a service domain.  The result works just like in the physical world, the network device sends and receives ethernet packets, and the switch does all those things ethernet switches tend to do. If you look at the reference manual of Oracle VM Server for SPARC, there are numerous options for virtual switches and network devices.  Don't be confused, it's rather straight forward, really.  Let's start with the simple case, and work our way to some more sophisticated options later on.  In many cases, you'll want to have several guests that communicate with the outside world on the same ethernet segment.  In the real world, you'd connect each of these systems to the same ethernet switch.  So, let's do the same thing in the virtual world: root@sun # ldm add-vsw net-dev=nxge2 admin-vsw primary root@sun # ldm add-vnet admin-net admin-vsw mars root@sun # ldm add-vnet admin-net admin-vsw venus We've just created a virtual switch called "admin-vsw" and connected it to the physical device nxge2.  In the physical world, we'd have powered up our ethernet switch and installed a cable between it and our big enterprise datacenter switch.  We then created a virtual network interface for each one of the two guest systems "mars" and "venus" and connected both to that virtual switch.  They can now communicate with each other and with any system reachable via nxge2.  If primary were running Solaris 10, communication with the guests would not be possible.  This is different with Solaris 11, please see the Admin Guide for details.  Note that I've given both the vswitch and the vnet devices some sensible names, something I always recommend. Unless told otherwise, the LDoms Manager software will automatically assign MAC addresses to all network elements that need one.  It will also make sure that these MAC addresses are unique and reuse MAC addresses to play nice with all those friendly DHCP servers out there.  However, if we want to do this manually, we can also do that.  (One reason might be firewall rules that work on MAC addresses.)  So let's give mars a manually assigned MAC address: root@sun # ldm set-vnet mac-addr=0:14:4f:f9:c4:13 admin-net mars Within the guest, these virtual network devices have their own device driver.  In Solaris 10, they'd appear as "vnet0".  Solaris 11 would apply it's usual vanity naming scheme.  We can configure these interfaces just like any normal interface, give it an IP-address and configure sophisticated routing rules, just like on bare metal.  In many cases, using Jumbo Frames helps increase throughput performance.  By default, these interfaces will run with the standard ethernet MTU of 1500 bytes.  To change this,  it is usually sufficient to set the desired MTU for the virtual switch.  This will automatically set the same MTU for all vnet devices attached to that switch.  Let's change the MTU size of our admin-vsw from the example above: root@sun # ldm set-vsw mtu=9000 admin-vsw primary Note that that you can set the MTU to any value between 1500 and 16000.  Of course, whatever you set needs to be supported by the physical network, too. Another very common area of network configuration is VLAN tagging. This can be a little confusing - my advise here is to be very clear on what you want, and perhaps draw a little diagram the first few times.  As always, keeping a configuration simple will help avoid errors of all kind.  Nevertheless, VLAN tagging is very usefull to consolidate different networks onto one physical cable.  And as such, this concept needs to be carried over into the virtual world.  Enough of the introduction, here's a little diagram to help in explaining how VLANs work in LDoms: Let's remember that any VLANs not explicitly tagged have the default VLAN ID of 1. In this example, we have a vswitch connected to a physical network that carries untagged traffic (VLAN ID 1) as well as VLANs 11, 22, 33 and 44.  There might also be other VLANs on the wire, but the vswitch will ignore all those packets.  We also have two vnet devices, one for mars and one for venus.  Venus will see traffic from VLANs 33 and 44 only.  For VLAN 44, venus will need to configure a tagged interface "vnet44000".  For VLAN 33, the vswitch will untag all incoming traffic for venus, so that venus will see this as "normal" or untagged ethernet traffic.  This is very useful to simplify guest configuration and also allows venus to perform Jumpstart or AI installations over this network even if the Jumpstart or AI server is connected via VLAN 33.  Mars, on the other hand, has full access to untagged traffic from the outside world, and also to VLANs 11,22 and 33, but not 44.  On the command line, we'd do this like this: root@sun # ldm add-vsw net-dev=nxge2 pvid=1 vid=11,22,33,44 admin-vsw primary root@sun # ldm add-vnet admin-net pvid=1 vid=11,22,33 admin-vsw mars root@sun # ldm add-vnet admin-net pvid=33 vid=44 admin-vsw venus Finally, I'd like to point to a neat little option that will make your live easier in all those cases where configurations tend to change over the live of a guest system.  It's the "id=<somenumber>" option available for both vswitches and vnet devices.  Normally, Solaris in the guest would enumerate network devices sequentially.  However, it has ways of remembering this initial numbering.  This is good in the physical world.  In the virtual world, whenever you unbind (aka power off and disassemble) a guest system, remove and/or add network devices and bind the system again, chances are this numbering will change.  Configuration confusion will follow suit.  To avoid this, nail down the initial numbering by assigning each vnet device it's device-id explicitly: root@sun # ldm add-vnet admin-net id=1 admin-vsw venus Please consult the Admin Guide for details on this, and how to decipher these network ids from Solaris running in the guest. Thanks for reading this far.  Links for further reading are essentially only the Admin Guide and Reference Manual and can be found above.  I hope this is useful and, as always, I welcome any comments.

    Read the article

  • Device driver with generic communication media layer

    - by Tom
    Greetings all, I'm trying to implement driver for an embedded device with generic communication media layer. Not sure what is the best way to do it so I'm seeking an advice from more experienced stackoverflow users:). Basically we've got devices around the country communicating with our head office. Usual form of communication is over TCP/IP, but could be also using usb, RF dongle, IR, etc. The plan is to have object corresponding with each of these devices, handling the proprietary protocol on one side and requests/responses from other internal systems on the other. The thing is how create something generic in between the media and the handling objects. I had a play around with the TCP dispatcher using boost.asio but trying to create something generic seems like a nightmare :). Anybody tried to do something like that? What is the best way how to do it? Cheers, Tom

    Read the article

  • Android ConnectivityManager information

    - by Mike
    I am trying to get a better grip on Android's ConnectivityManager and how it really works under the hood. Using the API is simple enough but I am looking for something lower level such as when it starts and the dirty details of what its doing in the background. I can't seem to find a good resource about it. Everything is just about using the API. Does anyone understand this or have any resources that they could point me to, website, book, white paper, or otherwise? I would really appreciate it. Thanks

    Read the article

  • recv with MSG_NONBLOCK and MSG_WAITALL

    - by osgx
    Hello I want to use recv syscall with nonblocking flags MSG_NONBLOCK. But with this flag syscall can return before full request is satisfied. So, can I add MSG_WAITALL flag? Will it be nonblocking? or how should I rewrite blocking recv into the loop with nonblocking recv

    Read the article

  • Reinforcement learning toy project

    - by Betamoo
    My toy project to learn & apply Reinforcement Learning is: - An agent tries to reach a goal state "safely" & "quickly".... - But there are projectiles and rockets that are launched upon the agent in the way. - The agent can determine rockets position -with some noise- only if they are "near" - The agent then must learn to avoid crashing into these rockets.. - The agent has -rechargable with time- fuel which is consumed in agent motion - Continuous Actions: Accelerating forward - Turning with angle I need some hints and names of RL algorithms that suit that case.. - I think it is POMDP , but can I model it as MDP and just ignore noise? - In case POMDP, What is the recommended way for evaluating probability? - Which is better to use in this case: Value functions or Policy Iterations? - Can I use NN to model environment dynamics instead of using explicit equations? - If yes, Is there a specific type/model of NN to be recommended? - I think Actions must be discretized, right? I know it will take time and effort to learn such a topic, but I am eager to.. You may answer some of the questions if you can not answer all... Thanks

    Read the article

  • TimoutException occurs over a network but not locally

    - by Gibsnag
    I have a program with three WCF services and when I run them locally (i.e: Server and Clients are all on localhost) everything works. However when I test them across a network I get a TimoutException on two services but not the other. I've disabled the firewalls on all the machines involved in the test. I can both ping the server and access the wsdl "You have created a service" webpage from the client The service that works uses a BasicHttpBinding with streaming and the two which don't work use WSDualHttpBinding. The Services that use WSDualHttpBinding both have CallbackContracts. I apologise for the vagueness of this question but I'm not really sure what code to include or where to even start looking for the solution to this. Non-working bindings: public static Binding CreateHTTPBinding() { var binding = new WSDualHttpBinding(); binding.MessageEncoding = WSMessageEncoding.Mtom; binding.MaxBufferPoolSize = 2147483647; binding.MaxReceivedMessageSize = 2147483647; binding.Security.Mode = WSDualHttpSecurityMode.None; return binding; } Exception Stack Trace: Unhandled Exception: System.TimeoutException: The open operation did not complete within the allotted timeout of 00:01:00. The time allotted to this operation may have been a portion of a longer timeout. Server stack trace: at System.ServiceModel.Channels.ReliableRequestor.ThrowTimeoutException() at System.ServiceModel.Channels.ReliableRequestor.Request(TimeSpan timeout) at System.ServiceModel.Channels.ClientReliableSession.Open(TimeSpan timeout) at System.ServiceModel.Channels.ClientReliableDuplexSessionChannel.OnOpen(TimeSpan timeout) at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout) at System.ServiceModel.Channels.ServiceChannel.OnOpen(TimeSpan timeout) at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout) at System.ServiceModel.Channels.ServiceChannel.CallOpenOnce.System.ServiceModel.Channels.ServiceChannel.ICallOnce.Call(ServiceChannel channel, TimeSpan timeout) at System.ServiceModel.Channels.ServiceChannel.CallOnceManager.CallOnce(TimeSpan timeout, CallOnceManager cascade) at System.ServiceModel.Channels.ServiceChannel.EnsureOpened(TimeSpan timeout) at System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs, TimeSpan timeout) at System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs) at System.ServiceModel.Channels.ServiceChannelProxy.InvokeService(IMethodCallMessage methodCall, ProxyOperationRuntime operation) at System.ServiceModel.Channels.ServiceChannelProxy.Invoke(IMessage message) Exception rethrown at [0]: at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg) at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type) at IDemeService.Register() at DemeServiceClient.Register() at DemeClient.Client.Start() at DemeClient.Program.Main(String[] args)

    Read the article

  • USB mouse does not work on boot

    - by Uku Loskit
    My problem is pretty much a duplicate of the one described in USB mouse late to load , but the solution there has not worked for me. I'm running the same OS and experiencing the exact same issue. It disappears after 10 seconds or so. Booting with the options specified in the other question did not fix it :/ Thanks in advance. sheepz@sheepz-desktop:~$ dmesg | egrep "hci|usb" [ 0.188000] usbcore: registered new interface driver usbfs [ 0.188000] usbcore: registered new interface driver hub [ 0.188000] usbcore: registered new device driver usb [ 0.358613] ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver [ 0.358627] ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver [ 0.358637] uhci_hcd: USB Universal Host Controller Interface driver [ 0.358683] uhci_hcd 0000:00:1d.0: PCI INT A -> GSI 23 (level, low) -> IRQ 23 [ 0.358691] uhci_hcd 0000:00:1d.0: setting latency timer to 64 [ 0.358695] uhci_hcd 0000:00:1d.0: UHCI Host Controller [ 0.358726] uhci_hcd 0000:00:1d.0: new USB bus registered, assigned bus number 1 [ 0.358758] uhci_hcd 0000:00:1d.0: irq 23, io base 0x0000e100 [ 0.358927] uhci_hcd 0000:00:1d.1: PCI INT B -> GSI 19 (level, low) -> IRQ 19 [ 0.358932] uhci_hcd 0000:00:1d.1: setting latency timer to 64 [ 0.358935] uhci_hcd 0000:00:1d.1: UHCI Host Controller [ 0.358964] uhci_hcd 0000:00:1d.1: new USB bus registered, assigned bus number 2 [ 0.358991] uhci_hcd 0000:00:1d.1: irq 19, io base 0x0000e200 [ 0.359132] uhci_hcd 0000:00:1d.2: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 0.359137] uhci_hcd 0000:00:1d.2: setting latency timer to 64 [ 0.359139] uhci_hcd 0000:00:1d.2: UHCI Host Controller [ 0.359165] uhci_hcd 0000:00:1d.2: new USB bus registered, assigned bus number 3 [ 0.359193] uhci_hcd 0000:00:1d.2: irq 18, io base 0x0000e300 [ 0.359327] uhci_hcd 0000:00:1d.3: PCI INT D -> GSI 16 (level, low) -> IRQ 16 [ 0.359332] uhci_hcd 0000:00:1d.3: setting latency timer to 64 [ 0.359334] uhci_hcd 0000:00:1d.3: UHCI Host Controller [ 0.359360] uhci_hcd 0000:00:1d.3: new USB bus registered, assigned bus number 4 [ 0.359387] uhci_hcd 0000:00:1d.3: irq 16, io base 0x0000e400 [ 0.731933] usb 1-1: new full speed USB device using uhci_hcd and address 2 [ 1.023859] usb 1-2: new full speed USB device using uhci_hcd and address 3 [ 16.136175] usb 1-2: device descriptor read/64, error -110 [ 31.352481] usb 1-2: device descriptor read/64, error -110 [ 31.568485] usb 1-2: new full speed USB device using uhci_hcd and address 4 [ 46.680794] usb 1-2: device descriptor read/64, error -110 [ 61.903555] usb 1-2: device descriptor read/64, error -110 [ 62.119671] usb 1-2: new full speed USB device using uhci_hcd and address 5 [ 72.541078] usb 1-2: device not accepting address 5, error -110 [ 72.653194] usb 1-2: new full speed USB device using uhci_hcd and address 6 [ 83.066637] usb 1-2: device not accepting address 6, error -110 [ 83.178615] usb 3-1: new low speed USB device using uhci_hcd and address 2 [ 83.562546] usbcore: registered new interface driver hiddev [ 83.578827] input: Logitech USB-PS/2 Optical Mouse as /devices/pci0000:00/0000:00:1d.2/usb3/3-1/3-1:1.0/input/input3 [ 83.579016] generic-usb 0003:046D:C01D.0001: input,hidraw0: USB HID v1.10 Mouse [Logitech USB-PS/2 Optical Mouse] on usb-0000:00:1d.2-1/input0 [ 83.579244] usbcore: registered new interface driver usbhid [ 83.579246] usbhid: USB HID core driver [114025.224407] usb 3-1: USB disconnect, address 2 sheepz@sheepz-desktop:~$ dmesg | egrep "hci|usb" [ 0.188000] usbcore: registered new interface driver usbfs [ 0.188000] usbcore: registered new interface driver hub [ 0.188000] usbcore: registered new device driver usb [ 0.358613] ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver [ 0.358627] ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver [ 0.358637] uhci_hcd: USB Universal Host Controller Interface driver [ 0.358683] uhci_hcd 0000:00:1d.0: PCI INT A -> GSI 23 (level, low) -> IRQ 23 [ 0.358691] uhci_hcd 0000:00:1d.0: setting latency timer to 64 [ 0.358695] uhci_hcd 0000:00:1d.0: UHCI Host Controller [ 0.358726] uhci_hcd 0000:00:1d.0: new USB bus registered, assigned bus number 1 [ 0.358758] uhci_hcd 0000:00:1d.0: irq 23, io base 0x0000e100 [ 0.358927] uhci_hcd 0000:00:1d.1: PCI INT B -> GSI 19 (level, low) -> IRQ 19 [ 0.358932] uhci_hcd 0000:00:1d.1: setting latency timer to 64 [ 0.358935] uhci_hcd 0000:00:1d.1: UHCI Host Controller [ 0.358964] uhci_hcd 0000:00:1d.1: new USB bus registered, assigned bus number 2 [ 0.358991] uhci_hcd 0000:00:1d.1: irq 19, io base 0x0000e200 [ 0.359132] uhci_hcd 0000:00:1d.2: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 0.359137] uhci_hcd 0000:00:1d.2: setting latency timer to 64 [ 0.359139] uhci_hcd 0000:00:1d.2: UHCI Host Controller [ 0.359165] uhci_hcd 0000:00:1d.2: new USB bus registered, assigned bus number 3 [ 0.359193] uhci_hcd 0000:00:1d.2: irq 18, io base 0x0000e300 [ 0.359327] uhci_hcd 0000:00:1d.3: PCI INT D -> GSI 16 (level, low) -> IRQ 16 [ 0.359332] uhci_hcd 0000:00:1d.3: setting latency timer to 64 [ 0.359334] uhci_hcd 0000:00:1d.3: UHCI Host Controller [ 0.359360] uhci_hcd 0000:00:1d.3: new USB bus registered, assigned bus number 4 [ 0.359387] uhci_hcd 0000:00:1d.3: irq 16, io base 0x0000e400 [ 0.731933] usb 1-1: new full speed USB device using uhci_hcd and address 2 [ 1.023859] usb 1-2: new full speed USB device using uhci_hcd and address 3 [ 16.136175] usb 1-2: device descriptor read/64, error -110 [ 31.352481] usb 1-2: device descriptor read/64, error -110 [ 31.568485] usb 1-2: new full speed USB device using uhci_hcd and address 4 [ 46.680794] usb 1-2: device descriptor read/64, error -110 [ 61.903555] usb 1-2: device descriptor read/64, error -110 [ 62.119671] usb 1-2: new full speed USB device using uhci_hcd and address 5 [ 72.541078] usb 1-2: device not accepting address 5, error -110 [ 72.653194] usb 1-2: new full speed USB device using uhci_hcd and address 6 [ 83.066637] usb 1-2: device not accepting address 6, error -110 [ 83.178615] usb 3-1: new low speed USB device using uhci_hcd and address 2 [ 83.562546] usbcore: registered new interface driver hiddev [ 83.578827] input: Logitech USB-PS/2 Optical Mouse as /devices/pci0000:00/0000:00:1d.2/usb3/3-1/3-1:1.0/input/input3 [ 83.579016] generic-usb 0003:046D:C01D.0001: input,hidraw0: USB HID v1.10 Mouse [Logitech USB-PS/2 Optical Mouse] on usb-0000:00:1d.2-1/input0 [ 83.579244] usbcore: registered new interface driver usbhid [ 83.579246] usbhid: USB HID core driver

    Read the article

< Previous Page | 185 186 187 188 189 190 191 192 193 194 195 196  | Next Page >