Search Results

Search found 4885 results on 196 pages for 'mike green'.

Page 19/196 | < Previous Page | 15 16 17 18 19 20 21 22 23 24 25 26  | Next Page >

  • SDL_DisplayFormat works, but not SDL_DisplayFormatAlpha

    - by Bounderby
    The following code is intended to display a green square on a black background. It executes, but the green square does not show up. However, if I change SDL_DisplayFormatAlpha to SDL_DisplayFormat the square is rendered correctly. So what don't I understand? It seems to me that I am creating *surface with an alpha mask and I am using SDL_MapRGBA to map my green color, so it would be consistent to use SDL_DisplayFormatAlpha as well. (I removed error-checking for clarity, but none of the SDL API calls fail in this example.) #include <SDL.h> int main(int argc, const char *argv[]) { SDL_Init( SDL_INIT_EVERYTHING ); SDL_Surface *screen = SDL_SetVideoMode( 640, 480, 32, SDL_HWSURFACE | SDL_DOUBLEBUF ); SDL_Surface *temp = SDL_CreateRGBSurface( SDL_HWSURFACE, 100, 100, 32, 0, 0, 0, ( SDL_BYTEORDER == SDL_BIG_ENDIAN ? 0x000000ff : 0xff000000 ) ); SDL_Surface *surface = SDL_DisplayFormatAlpha( temp ); SDL_FreeSurface( temp ); SDL_FillRect( surface, &surface->clip_rect, SDL_MapRGBA( screen->format, 0x00, 0xff, 0x00, 0xff ) ); SDL_Rect r; r.x = 50; r.y = 50; SDL_BlitSurface( surface, NULL, screen, &r ); SDL_Flip( screen ); SDL_Delay( 1000 ); SDL_Quit(); return 0; }

    Read the article

  • How to insert a word into a string in Perl

    - by Nano HE
    #!C:\Perl\bin\perl.exe use strict; use warnings; use Data::Dumper; my $fh = \*DATA; while(my $line = <$fh>) { $line =~ s/ ^/male /x ; print $line ; } __DATA__ 1 0104 Mike Lee 2:01:48 output male 1 0104 Mike Lee 2:01:48 Then I tried to insert male after the racenumber(0104), I replaced the code with style. $line =~ s/ ^\d+\s+\d+\s+ /male /x ; # but failed Acturally I want the output. thank you. 1 0104 male Mike Lee 2:01:48

    Read the article

  • How do I insert a word into a string in Perl?

    - by Nano HE
    #!C:\Perl\bin\perl.exe use strict; use warnings; use Data::Dumper; my $fh = \*DATA; while(my $line = <$fh>) { $line =~ s/ ^/male /x ; print $line ; } __DATA__ 1 0104 Mike Lee 2:01:48 output male 1 0104 Mike Lee 2:01:48 Then I tried to insert male after the racenumber(0104), I replaced the code with style. $line =~ s/ ^\d+\s+\d+\s+ /male /x ; # but failed Acturally I want the output. thank you. 1 0104 male Mike Lee 2:01:48

    Read the article

  • What is the best way to join/merge two tables by column cell matching in Excel?

    - by blunders
    I've found this excel add-in to buy that appears to do what I need, but I'd rather have code that's open to use as I wish. While a GUI is nice, it's not required. In an attempt to make the question more clear, I'm adding some two sample "input" tables in tab delimited form, and the resulting output table: SAMPLE_INPUT_TABLE_01 NAME<tab>Location John<tab>US Mike<tab>CN Tom<tab>CA Sue<tab>RU SAMPLE_INPUT_TABLE_02 NAME<tab>Age John<tab>18 Mike<tab>36 Tom<tab>54 Mary<tab>18 SAMPLE_OUTPUT_TABLE_02 NAME<tab>Age<Location> John<tab>18<tab>US Mike<tab>36<tab>CN Tom<tab>54<tab>CA Sue<tab>""<tab>RU Mary<tab>18<tab>"" If it matters, I'm using Office 2010 on Windows 7.

    Read the article

  • Where to look for real url

    - by smallB
    I'm trying to write simple application for downloading videos from youtube. My code for getting file (http://www.youtube.com/watch?v=pViMzR_ylXg) looks like: bool FD_core::get_file() { QNetworkRequest request; request.setUrl(QUrl("http://www.youtube.com/watch?v=pViMzR_ylXg")); connect(network_access_manager_, SIGNAL(finished(QNetworkReply*)), this, SLOT(onRequestCompleted(QNetworkReply *))); network_access_manager_->get(request); return true; } void FD_core::onRequestCompleted(QNetworkReply * reply) { QByteArray data_ = reply->readAll(); cout << data_.constData(); qDebug() << "size: " << data_.size(); } In the above function data_.constData() produces lots of text, part (very small) of it: <!DOCTYPE html> <html lang="en" dir="ltr" > <head> <script> var yt = yt || {};yt.timing = yt.timing || {};yt.timing.tick = function(label, opt_time) {var timer = yt.timing['timer'] || {};if(opt_time) {timer[label] = opt_time;}else {timer[label] = new Date().getTime();}yt.timing['timer'] = timer;};yt.timing.info = function(label, value) {var info_args = yt.timing['info_args'] || {};info_args[label] = value;yt.timing['info_args'] = info_args;};yt.timing.info('e', "907050,906359,927900,919320,914021,916611,922401,920704,912806,927201,925706,928001,922403,913546,913556,920201,911116,901451");yt.timing.wff = true;yt.timing.info('pr', "1");yt.timing.info('an', "dclk,aftv,afv");if (document.webkitVisibilityState == 'prerender') {document.addEventListener('webkitvisibilitychange', function() {yt.timing.tick('start');}, false);}yt.timing.tick('start');yt.timing.info('li','0');try {yt.timing['srt'] = window.gtbExternal && window.gtbExternal.pageT() ||window.external && window.external.pageT;} catch(e) {}if (window.chrome && window.chrome.csi) {yt.timing['srt'] = Math.floor(window.chrome.csi().pageT);}if (window.msPerformance && window.msPerformance.timing) {yt.timing['srt'] = window.msPerformance.timing.responseStart - window.msPerformance.timing.navigationStart;} </script> <script>var yt = yt || {};yt.preload = {};yt.preload.counter_ = 0;yt.preload.start = function(src) {var img = new Image();var counter = ++yt.preload.counter_;yt.preload[counter] = img;img.onload = img.onerror = function () {delete yt.preload[counter];};img.src = src;img = null;};yt.preload.start("http:\/\/o-o---preferred---sn-xn5ucu-q0ce---v3---lscache7.c.youtube.com\/crossdomain.xml");yt.preload.start("http:\/\/o-o---preferred---sn-xn5ucu-q0ce---v3---lscache7.c.youtube.com\/generate_204?ip=95.83.224.63\u0026upn=A3aUhLYV55M\u0026sparams=algorithm%2Cburst%2Ccp%2Cfactor%2Cgcr%2Cid%2Cip%2Cipbits%2Citag%2Csource%2Cupn%2Cexpire\u0026fexp=907050%2C906359%2C927900%2C919320%2C914021%2C916611%2C922401%2C920704%2C912806%2C927201%2C925706%2C928001%2C922403%2C913546%2C913556%2C920201%2C911116%2C901451\u0026mt=1354207274\u0026key=yt1\u0026algorithm=throttle-factor\u0026burst=40\u0026ipbits=8\u0026itag=34\u0026sver=3\u0026signature=692E605215EB4D2CA407291CA26E14B844768A89.7A2930CE25FDDFC7C4FF5AA56DD02538B0020267\u0026mv=m\u0026source=youtube\u0026ms=au\u0026gcr=ie\u0026expire=1354228237\u0026factor=1.25\u0026cp=U0hUSVJNVl9IUUNONF9KR1pDOi0tSFhhRzVFRkd6\u0026id=a5588ccd1ff29578");</script><title>Die Antwoord - Fok Julle Naaiers (Mike Tyson&#39;s Words NOT DJ Hi-Teks) - YouTube</title><link rel="search" type="application/opensearchdescription+xml" href="http://www.youtube.com/opensearch?locale=en_US" title="YouTube Video Search"><link rel="icon" href="http://s.ytimg.com/yts/img/favicon-vfldLzJxy.ico" type="image/x-icon"><link rel="shortcut icon" href="http://s.ytimg.com/yts/img/favicon-vfldLzJxy.ico" type="image/x-icon"> <link rel="icon" href="//s.ytimg.com/yts/img/favicon_32-vflWoMFGx.png" sizes="32x32"><link rel="canonical" href="/watch?v=pViMzR_ylXg"><link rel="alternate" media="handheld" href="http://m.youtube.com/watch?v=pViMzR_ylXg"><link rel="alternate" media="only screen and (max-width: 640px)" href="http://m.youtube.com/watch?v=pViMzR_ylXg"><link rel="shortlink" href="http://youtu.be/pViMzR_ylXg"> <meta name="title" content="Die Antwoord - Fok Julle Naaiers (Mike Tyson&#39;s Words NOT DJ Hi-Teks)"> <meta name="description" content="Some of the lyrics of &quot;Die Antwoord&quot; new single &quot;Fok Julle Naaiers&quot; have caused such controversy that Die Antwoord have split with their record label Intersc..."> <meta name="keywords" content="Die Antwoord, Fok Julle Naaiers, Mike Tyson, DJ Hi-Tek, Faggot"> <link rel="alternate" type="application/json+oembed" href="http://www.youtube.com/oembed?url=http%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3DpViMzR_ylXg&amp;format=json" title="Die Antwoord - Fok Julle Naaiers (Mike Tyson&#39;s Words NOT DJ Hi-Teks)"> <link rel="alternate" type="text/xml+oembed" href="http://www.youtube.com/oembed?url=http%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3DpViMzR_ylXg&amp;format=xml" title="Die Antwoord - Fok Julle Naaiers (Mike Tyson&#39;s Words NOT DJ Hi-Teks)"> <meta property="og:url" content="http://www.youtube.com/watch?v=pViMzR_ylXg"> <meta property="og:title" content="Die Antwoord - Fok Julle Naaiers (Mike Tyson&#39;s Words NOT DJ Hi-Teks)"> <meta property="og:description" content="Some of the lyrics of &quot;Die Antwoord&quot; new single &quot;Fok Julle Naaiers&quot; have caused such controversy that Die Antwoord have split with their record label Intersc..."> <meta property="og:type" content="video"> <meta property="og:image" content="http://i1.ytimg.com/vi/pViMzR_ylXg/mqdefault.jpg"> <meta property="og:video" content="http://www.youtube.com/v/pViMzR_ylXg?version=3&amp;autohide=1"> <meta property="og:video:type" content="application/x-shockwave-flash"> <meta property="og:video:width" content="853"> <meta property="og:video:height" content="480"> <meta property="og:site_name" content="YouTube"> <meta property="fb:app_id" content="87741124305"> <meta name="twitter:card" value="player"> <meta name="twitter:site" value="@youtube"> <meta name="twitter:player" value="https://www.youtube.com/embed/pViMzR_ylXg"> <meta property="twitter:player:width" content="853"> <meta property="twitter:player:height" content="480"> So my question is, where in this file is the url hidden which will allow me to download the wanted file?

    Read the article

  • Regexing it up with IIS re-write module

    - by Michael Jasper
    I am developing a profile-based web application where each user is assigned there own url through their username & iis rewrite mod's magic. A typical user's profile url would be http://www.mymark.com/mike Each user is also created a blog in a multi-user wordpress installation. The wordpress url would look like this: http://www.mymark.com/blog/mike I am trying to use the rewrite module to create more canonical urls for the user (http://www.mymark.com/mike/blog), and have tried several regex variations that I have created through RegExr(a regex generation tool) and come up with this as the pattern to match (www.|)mymark.com/([^/]+)/blog but haven't had any success so far. What am I doing wrong here? Here is a screen shot of my re-write rule:

    Read the article

  • How to put .com at the end of email addressed by regex?

    - by terces907
    Example I received a email-list from my friends but the problem is some people typed an email in full form ([email protected]) and some people typed (xxx@xxx without .com). And i want to improve it into the same format. How can i improve it if i want to edit them on vi? In my emaillist.txt foo@gmail [email protected] bas@gmail [email protected] mike@abc john@email My try: i tried to use an easy regex like this to catch the pattern like xxx@xxx :%s/\(\w*@\w*\)/\0.com/g and :%s/\(\w*@\w*[^.com]\)/\0.com/g But the problem is this regex include [email protected] also And the result become like this after i enter the command above [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] So, My expectation after substitution is should be like this: [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] How to use regex in this situation?

    Read the article

  • javascript filter array of objects

    - by user441521
    I have an array of objects and I'm wondering the best way to search it. Given the below example how can I search for name = "Joe" and age < 30? Is there anything jQuery can help with or do I have to brute force this search myself? var names = new Array(); var object = { name : "Joe", age:20, email: "[email protected]"}; names.push(object); object = { name : "Mike", age:50, email: "[email protected]"}; names.push(object); object = { name : "Joe", age:45, email: "[email protected]"}; names.push(object);

    Read the article

  • Secondary monitor bug: a problem in WPF or in the graphics driver?

    - by emddudley
    I have discovered a strange bug with my WPF application and I am trying to determine whether it is a problem with WPF or my graphics driver so that I can report it to the appropriate company. I have a Quadro FX 1700 with the latest drivers (197.54) on a Windows XP system, running a .NET 3.5 SP1 application. I have dual monitors, and when I maximize then minimize a child window of the main window on my primary monitor, the child window gets drawn on the secondary monitor as well. It appears in both places. I made a sample application (code is below) which induces this behavior. Start the application and ensure the main window is on your primary monitor. Double-click the main window. A green child window should appear. Click the green child window to maximize. Click the green child window to minimize. Can anyone else reproduce this problem? On my system the green child restores, but then it's drawn on both my primary and secondary monitors, rather than just the primary monitor. App.xaml <Application xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" x:Class="DualMonitorBug.App" StartupUri="Shell.xaml" /> App.xaml.cs using System.Windows; namespace DualMonitorBug { public partial class App : Application { } } Shell.xaml <Window xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" x:Class="DualMonitorBug.Shell" Title="Shell" Height="480" Width="640" MouseDoubleClick="ShowDialog" /> Shell.xaml.cs using System.Windows; using System.Windows.Input; namespace DualMonitorBug { public partial class Shell : Window { public Shell() { InitializeComponent(); } private void ShowDialog(object sender, MouseButtonEventArgs e) { DialogWindow dialog = new DialogWindow(); dialog.Owner = this; dialog.Show(); } } } DialogWindow.xaml <Window xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" x:Class="DualMonitorBug.DialogWindow" Title="Dialog Window" Height="240" Width="320" AllowsTransparency="True" Background="Green" MouseLeftButtonDown="ShowHideDialog" WindowStyle="None" /> DialogWindow.xaml.cs using System.Windows; using System.Windows.Input; namespace DualMonitorBug { public partial class DialogWindow : Window { public DialogWindow() { InitializeComponent(); } private void ShowHideDialog(object sender, MouseButtonEventArgs e) { this.WindowState = (this.WindowState == WindowState.Normal) ? WindowState.Maximized : WindowState.Normal; } } }

    Read the article

  • How does this ajax call persist DOM changes in the browser cache?

    - by Greg
    For the purpose of the question I need to create a simple fictitious scenario. I have the following trivial page with one link, call it page A: <a class="red-anchor" onclick="change_color(event);" href="http://mysite.com/b/">B</a> With the associated Javascript function: function change_color(e) { var event = e || window.event; var link = event.target; link.className = "green-anchor"; } And I have the appropriate CSS to make the anchor red or green based on the classname. This is working. That is, when I click the anchor it changes color from red to green, which is briefly visible before the browser loads page B. But if I then use the BACK button to return to page A I get different behavior in different browsers. In Safari, the anchor is still green (desired behavior) In Firefox it reverts to red I imagine that Safari is somehow updating its cached version of the page, whereas Firefox isn't. So my first question is: is there any way to get FF to update the cached page, or is something else happening here? Secondly: I have a different implementation where I use an ajax call. In this I set the class of the anchor using a session variable, something like... <a class="<?php echo $_SESSION["color"]; ?>" ...[snip]... >B</a> And the javascript function makes an additional ajax call that changes the "color" session variable. In this case both Safari and Firefox work as expected. When going back from B to A the color is still green. But I can't for the life of me figure out why it should be different to the non-ajax case. I have tried many different permutations and for it to work on FF the "color" session variable MUST change (i.e. the ajax call itself is not somehow reloading the cache). But on coming BACK, the page is being reloaded from the cache (verified in Firebug), so how is the page even accessing this session variable if it isn't reprocessing the page and running that fragment of php in the anchor? I figure there must be something fundamental here that I am not understanding. Any insight would be much appreciated.

    Read the article

  • Determine the 'Overtype' mode using Javascript

    - by Snorkpete
    We are creating a web app to replace an old-school green-screen application. In the green-screen app, as the user presses the Insert key to switch between overtype and insert modes, the cursor changes to indicate which input mode the user is currently in. In IE (which is the official browser of the company), overtype mode also works, but there's no visual indication as to whether overtype mode is on or not, until the user starts typing and possibly over-writes existing information unexpectedly. I'd like to put some sort of visual indicator on the screen if in overtype mode. How can you determine if the browser is in 'overtype mode' from Javascript? Is there some property or function i can query to determine if the browser is in overtype mode? Even an IE-specific solution would be helpful, since our corporate policy dictates the browser to use as IE7 (pure torture, btw). (I do know that one solution is to do check for key presses of the Insert key. However, it's a solution that I'd prefer to avoid since that method seems a bit flaky & error-prone because I can't guarantee what mode the user would be in BEFORE he/she hits my page. ) The reasoning behind this question: The functionality of this portion of the green-screen app is such that the user can select from a list of 'preformatted bodies of text'. crude eg. The excess for this policy is: $xxxxxx and max limit is:$xxxxxx Date of policy is: xx/xx/xxxx and expires : xx/xx/xxxx Some other irrelevant text After selecting this 'preformatted text', the user would then use overtype to replace the x's with actual values, without disturbing the alignment of the rest of the text. (To be clear, they can still edit any part of the 'preformatted text' if they so wished. It's just that usually, they just wish to replace specific portions of the text. Keeping the alignment is important since these sections of text can end up on printed documents.) Of course, the same effect can be achieved by just selecting the x's to replace first, but it would be helpful (with respect to easing the transition to the web app) to allow old methods of doing things to continue to work, while still allowing 'web methods' to be used by the more tech-savvy users. Essentially, we're trying to make the initial transition from the green-screen app to the web app be as seemless as possible to minimise the resistance from the long-time green-screeners.

    Read the article

  • How many bits for sequence number using Go-Back-N protocol.

    - by Mike
    Hi Everyone, I'm a regular over at Stack Overflow (Software developer) that is trying to get through a networking course. I got a homework problem I'd like to have a sanity check on. Here is what I got. Q: A 3000-km-long T1 trunk is used to transmit 64-byte frames using Go-Back-N protocol. If the propagation speed is 6 microseconds/km, how many bits should the sequence numbers be? My Answer: For this questions what we need to do is lay the base knowledge. What we are trying to find is the size of the largest sequence number we should us using Go-Back-N. To figure this out we need to figure out how many packets can fit into our link at a time and then subtract one from that number. This will ensure that we never have two packets with the same sequence number at the same time in the link. Length of link: 3,000km Speed: 6 microseconds / km Frame size: 64 bytes T1 transmission speed: 1544kb/s (http://ckp.made-it.com/t1234.html) Propagation time = 6 microseconds / km * 3000 km = 18,000 microseconds (18ms). Convert 1544kb to bytes = 1544 * 1024 = 1581056 bytes Transmission time = 64 bytes / 1581056bytes / second = 0.000040479 seconds (0.4ms) So then if we take the 18ms propagation time and divide it by the 0.4ms transmission time we will see that we are going to be able to stuff ( 18 / 0.4) 45 packets into the link at a time. That means that our sequence number should be 2 ^ 45 bits long! Am I going in the right direction with this? Thanks, Mike

    Read the article

  • Are web service handler chains possible under IIS / ASP.NET

    - by Mike
    I'm working with a client who wants me to implement a particular design in an IIS/ASP.NET environment. This design was already implemented in Java, but I am not sure it is possible using Microsoft technologies. In a Tomcat/Java environment one can create so call Handler Chains. In essence a handler runs on the server on which the web service is running and it intercepts the SOAP message coming to the web service. The handler can perform a number of tasks before passing control to the web service. Some of these tasks may refer to authentication and authorization. Moreover, one can create handler chains, such that the handlers can run in a particular sequence before passing control to the web service. This is a very elegant solution, as certain aspects of authentication and authorization can be automatically performed, without the developer of the client application and of the web service having to invest anything in it. The code for the client application and the web service is not affected. You may find a number of articles on internet on this subject by searching on Google for "web service handler chain". I performed searches for web service handlers in IIS or ASP.NET. I get some hits, but apparently handlers in IIS have another meaning than that described above. My question therefor is: Can handler chains (as available in Java and Tomcat) be created in IIS? If so, how (any article, book, forum...)? Either a negative or a positive answer will be greatly appreciated. Mike

    Read the article

  • Read Only Domain Controllers and DNS zone updates

    - by Mike M
    I have a Windows 2003 domain and just added a new DC that runs 2008 R2. I updated the schema accordingly for both forest and domain levels. I also made sure to run /rodcprep at the time I did this. I have a branch office with a 2008 R2 file/print server that is a read-only domain controller (DC). The one problem I have been having is with AD-integrated DNS records updates. In the data center, we had to make an IP address change on a particular server. All our other sites' DCs (2003) updated the record fine. The 2008 R2 DC in the data center also updates its record fine. However, the RODC in the branch office does not. So if I nslookup the target server on a 2003 DC, the IP address is correct. Same with the 2008 R2 DC in the data center. But an nslookup on the branch office RODC still pulls in the old IP address. Moreover, any new records we've created (e.g., just added a new terminal server) do not get updated on the branch RODC either. Is there something simple I'm missing? How do I get the RODC to sync its AD-integrated DNS records with the rest of my world? Thank you in advance for your responses. Mike

    Read the article

  • SQL Server 2005 SP3 on Windows 7 - No Management Studio

    - by Mike Thomas
    I've been trying for a day and a half now to get SQL Server 2005, DEV edition, to work on Windows 7, 64 bit prof. I install from the disk, then run SP 3. I get a failure on the Client Components section of the Installation Progress along with this vague message - Product : Client Components Product Version (Previous): 1399 Product Version (Final) : Status : Failure Log File : C:\Program Files\Microsoft SQL Server\90\Setup Bootstrap\LOG\Hotfix\SQLTools9_Hotfix_KB955706_sqlrun_tools.msp.log Error Number : 1712 Error Description : MSP Error: 1712 One or more of the files required to restore your computer to its previous state could not be found. Restoration will not be possible. I've uninstalled all Visual Studio and tried to make this as clean as possible, and have read a lot of the blog posts, but am really at my wits end about this. I am not a DBA, but I use SQL Server all the time when coding and testing apps. Does anyone have any ideas as to where I can get this sorted out? I've been ati this for a long time and have never encountered an installation as bad as this one. Thanks Mike Thomas

    Read the article

  • Pivot tables: How can I total the subtotal?

    - by Mike
    Person A needs £115, Person D £234 and Person G £789, but how do I SUM that and get it to show on the same ROW as the subtotal? The Rows are subscription names. The Value field holds the Cost per subscription. the Columns holds the name of the person who receives the subscription. I have GROUPED on YEAR & MONTH, and have a subtotal that shows me how much each person will need to pay each month for all their subscriptions, but I need a figure showing me the total of all the subscriptions per month. I've tried adding calculated fields, but I want to SUM the subtotals so I'm struggling to see the field I need to use. I've tried Grand Totals but that SUMS all rows and I really only want SUM the Subtotal Total Row. I need a nice neat report that my managers won't go white at when looking at it...to many numbers = fear and confusion. Anyway it got messy, so I've come for help. Cheers Mike.

    Read the article

  • 2000 Server, User can't logon

    - by Mike I
    I hope you can help me. I recently upgraded a workstation at my office (to a whole new machine) and ran into a pretty serious problem. Friday until 5:00 PM, I could access my mail on 2000 Exchange server. When I shut the old workstation down and put in the new workstation, I tried to set up an account. When I put the server name in appropriate field and typed my username and hit check names, my username does not come up. So to troubleshoot, (It also is a SMB server) I try to logon to my file share. (My local credentials are the same as server credientials of user account) When I try to logon to share, I just get the Username/Password screen (Never had gotten that before since credentials are the same) Again, in troubleshooting mode, I try to log on to my user from another workstation. Still can't authenticate via my user. Every other user can authenticate and load up their shares/mailboxes. I have restored Exchange from the backup as of 3 days ago (Thursday) but the exact same issue is still there. I really do not understand what is wrong and what else I can do to troubleshoot. If anyone has some pointers for me, I will surely accept them. Thanks, Mike

    Read the article

  • Access 2007: How can I make this EXPRESSION less complex?

    - by Mike
    Access is telling me that my new expression is to complex. It used to work when we had 10 service levels, but now we have 19! Great! My expression is checking the COST of our services in the [PriceCharged] field and then assigning the appropriate HOURS [Servicelevel] when I perform a calculation to work out how much REVENUE each colleague has made when working for a client. The [EstimatedTime] field stores the actual hours each colleague has worked. [EstimatedTime]/[ServiceLevel]*[PriceCharged] Great. Below is the breakdown of my COST to HOURS expression. I've put them on different lines to make it easier to read - please do not be put off by the length of this post, it's all the same info in the end. Many thanks,Mike ServiceLevel: IIf([pricecharged]=100(COST),6(HOURS), IIf([pricecharged]=200 Or [pricecharged]=210,12.5, IIf([pricecharged]=300,19, IIf([pricecharged]=400 Or [pricecharged]=410,25, IIf([pricecharged]=500,31, IIf([pricecharged]=600,37.5, IIf([pricecharged]=700,43, IIf([pricecharged]=800 Or [pricecharged]=810,50, IIf([pricecharged]=900,56, IIf([pricecharged]=1000,62.5, IIf([pricecharged]=1100,69, IIf([pricecharged]=1200 Or [pricecharged]=1210,75, IIf([pricecharged]=1300 Or [pricecharged]=1310,100, IIf([pricecharged]=1400,125, IIf([pricecharged]=1500,150, IIf([pricecharged]=1600,175, IIf([pricecharged]=1700,200, IIf([pricecharged]=1800,225, IIf([pricecharged]=1900,250,0)))))))))))))))))))

    Read the article

  • Excel 2007: Named ranges problems when linking workbooks

    - by Mike
    I've 30+ workbooks each with 5 specific worksheets (formated the same). Each worksheet's data needs to be linked to a master workbook, so that I end up with 5 master workbooks and all the specific data in one long table format $A$2:$I$750. (Are you still with me? ;)) I don't have access to a database, so I'm having to link the sheets to their master workbook directly. I've highlighted the data I need; named the range; and then tried referencing this from my master workbook. I get the #Value error symbol when I try to link (=[WorkbookName]!MyNamedRange) to a cell that doesn't match the top left cell of my range. Example: MyNamedrange is always =$A$2:$I43$ on one specific sheet. On my master workbook it works if it's referenced at A2 but I get #Value if it's referenced A1, or A44. Any ideas? I'm trying to link my data in one continous table so I can run a pivot on it, and other things. Can it be done like this, or should I just copy and paste? I'm trying to keep things 'linked'so I do not need to spend time C&Ping all day. Many thanks Mike.

    Read the article

  • Blinking power button

    - by Mike Ramsey
    A friend asked me to look at his Gateway DX4640 desktop. When he presses the power button, power goes to the mobo (NVIDIA nForce 630i MCP73PV, GeForce 7100 chipset) and the CPU fan starts spinning. The power button slowely blinks on and off (blue) and the screen briefly says no signal and then goes black. And nothing else; no post code beeps. My initial two conjectures were: 1. Vista was stuck in sleep/hibernation mode, or 2. A power off had left the mobo in a bad state. The fix for both is to: a) Unplug the AC power cord b) hold the power button for 30 second to fully discharge the mobo It didn't help. I left the system unplugged from AC power for an hour. No change. I am out of ideas. Has anybody seen anything like this before? What does a blinking blue power button mean? How can I get more data points to guide trouble shooting? --Thank you, --Mike

    Read the article

  • Excael 2007: Name range problems when linking workbooks

    - by Mike
    I've 30+ workbooks each with 5 specific worksheets (formated the same). Each worksheet's data needs to be linked to a master workbook, so that I end up with 5 master workbooks and all the specific data in one long table format $A$2:$I$750. (Are you still with me? ;)) I don't have access to a database, so I'm having to link the sheets to their master workbook directly. I've highlighted the data I need; named the range; and then tried referencing this from my master workbook. I get the #Value error symbol when I try to link (=[WorkbookName]!MyNamedRange) to a cell that doesn't match the top left cell of my range. Example: MyNamedrange is always =$A$2:$I43$ on one specific sheet. On my master workbook it works if it's referenced at A2 but I get #Value if it's referenced A1, or A44. Any ideas? I'm trying to link my data in one continous table so I can run a pivot on it, and other things. Can it be done like this, or should I just copy and paste? I'm trying to keep things 'linked'so I do not need to spend time C&Ping all day. Many thanks Mike.

    Read the article

  • Ubuntu init.d script not being called on startup

    - by Mike
    I've got a script in ubuntu 9.04 in init.d that I've set to run on start on with update-rc.d using update-rc.d init_test defaults 99. All of the symlinks are there and the permissions appear to be correct -rwxr-xr-x 1 root root 642 2010-10-28 16:44 init_test mike@xxxxxxxxxx:~$ find /etc -name S99* | grep init_test find: /etc/rc5.d/S99init_test find: /etc/rc4.d/S99init_test find: /etc/rc2.d/S99init_test find: /etc/rc3.d/S99init_test The script runs through source and ./ without issue and behaves correctly. Here is the source of the script: #!/bin/bash ### BEGIN INIT INFO # Provides: init test script # Required-Start: $remote_fs $syslog # Required-Stop: $remote_fs $syslog # Default-Start: 2 3 4 5 # Default-Stop: 0 1 6 # Short-Description: Start daemon at boot time # Description: Enable service provided by daemon. ### END INIT INFO start() { echo "hi" echo "start called" >> /tmp/test.log return } stop() { echo "Stopping" } echo "Script called" >> /tmp/test.log case "$1" in start) start ;; stop) stop ;; *) echo "Usage: {start|stop|restart}" exit 1 ;; esac exit $? When the machine starts, I don't see "script called" or "start called" in the test.log at all. Is there anything obvious I'm messing up?

    Read the article

  • Access 2007: How can I make this EXPRESSION less complex?

    - by Mike
    Access is telling me that my new expression is to complex. It used to work when we had 10 service levels, but now we have 19! Great! My expression is checking the COST of our services in the [PriceCharged] field and then assigning the appropriate HOURS [Servicelevel] when I perform a calculation to work out how much REVENUE each colleague has made when working for a client. The [EstimatedTime] field stores the actual hours each colleague has worked. [EstimatedTime]/[ServiceLevel]*[PriceCharged] Great. Below is the breakdown of my COST to HOURS expression. I've put them on different lines to make it easier to read - please do not be put off by the length of this post, it's all the same info in the end. Many thanks,Mike ServiceLevel: IIf([pricecharged]=100(COST),6(HOURS), IIf([pricecharged]=200 Or [pricecharged]=210,12.5, IIf([pricecharged]=300,19, IIf([pricecharged]=400 Or [pricecharged]=410,25, IIf([pricecharged]=500,31, IIf([pricecharged]=600,37.5, IIf([pricecharged]=700,43, IIf([pricecharged]=800 Or [pricecharged]=810,50, IIf([pricecharged]=900,56, IIf([pricecharged]=1000,62.5, IIf([pricecharged]=1100,69, IIf([pricecharged]=1200 Or [pricecharged]=1210,75, IIf([pricecharged]=1300 Or [pricecharged]=1310,100, IIf([pricecharged]=1400,125, IIf([pricecharged]=1500,150, IIf([pricecharged]=1600,175, IIf([pricecharged]=1700,200, IIf([pricecharged]=1800,225, IIf([pricecharged]=1900,250,0)))))))))))))))))))

    Read the article

  • What You Can Learn from the NFL Referee Lockout

    - by Christina McKeon
    American football is a lot like religion. The fans are devoted followers that take brand loyalty to a whole new level. These fans that worship their teams each week showed that they are powerful customers whose voice has an impact. Yesterday, these fans proved that their opinion could force the hand of a large and powerful institution. With a three-month NFL referee lockout that seemed like it was nowhere close to resolution, the Green Bay Packers and the Seattle Seahawks competed last Monday night. For those of you that might have been out of the news cycle the past few days, Green Bay lost the game due to a controversial call that many experts and analysts agree should have resulted in Green Bay winning the game. Outrage ensued. The NFL had pulled replacement referees from the high school ranks, and these replacements did not have the knowledge and experience to handle high intensity NFL games. Fans protested about their customer experience. Their anger-filled rants were heard in social media, in the headlines of newspapers, on radio, and on national TV. Suddenly, the NFL was moved to reach an agreement with the referees. That agreement was reached late in the night on Wednesday with many believing that the referees had the upper hand forcing the owners into submission. Some might argue that the referees benefited, not the fans. Since the fans wanted qualified and competent referees, I would say the fans did benefit. The referees are scheduled to return to the field this Sunday, so the fans got what they wanted. What can you learn from this negative customer experience? Customers are in control. NFL owners thought they were controlling this situation with the upper hand over referees. The owners figured out they weren’t in control when their fans reacted negatively. Customers can make or break you more now than ever before, which is why it is more important to connect with them, engage them in a personal manner, and create rewarding relationships. Protect your brand. Whether knowingly or unknowingly, the NFL put their brand and each team’s brand at risk with replacement referees. Think about each business decision you make, and how it may impact your brand at different points in time. A decision that results in a gain today could result in a larger loss down the road. Customer experience matters. The NFL likely foresaw declining revenues in ticket sales, merchandising, advertising, and other areas if the lockout continued. While fans primarily spoke with their minds in the days following the Green Bay debacle, their wallets would be the next things to speak. Customer experience directly affects your success and is one of the few areas where you can differentiate your business. What would you do if your brand got such negative attention? Would you be prepared to navigate such stormy waters? Would you be able to prevent such a fiasco? If you don’t have a good answer to these questions, consider joining us October 3-5, 2012 at the Oracle Customer Experience Summit in San Francisco. You’ll have the opportunity to learn even more about customer experience from industry experts such as best-selling author Seth Godin, Paul Hagen and Kerry Bodine from Forrester Research, Inc., George Kembel from the Stanford d.School, Bruce Temkin of The Temkin Group, and Gene Alvarez from Gartner Inc.. There will also be plenty of your peers and customer experience experts available for networking and discussions.

    Read the article

  • Communication between state machines with hidden transitions

    - by slartibartfast
    The question emerged for me in embedded programming but I think it can be applied to quite a number of general networking situations e.g. when a communication partner fails. Assume we have an application logic (a program) running on a computer and a gadget connected to that computer via e.g. a serial interface like RS232. The gadget has a red/green/blue LED and a button which disables the LED. The LEDs color can be driven by software commands over the serial interface and the state (red/green/blue/off) is read back and causes a reaction in the application logic. Asynchronous behaviour of the application logic with regard to the LED color down to a certain delay (depending on the execution cycle of the application) is tolerated. What we essentially have is a resource (the LED) which can not be reserved and handled atomically by software because the (organic) user can at any time press the button to interfere/break the software attempt to switch the LED color. Stripping this example from its physical outfit I dare to say that we have two communicating state machines A (application logic) and G (gadget) where G executes state changes unbeknownst to A (and also the other way round, but this is not significant in our example) and only A can be modified at a reasonable price. A needs to see the reaction and state of G in one piece of information which may be (slightly) outdated but not inconsistent with respect to the short time window when this information was generated on the side of G. What I am looking for is a concise method to handle such a situation in embedded software (i.e. no layer/framework like CORBA etc. available). A programming technique which is able to map the complete behaviour of both participants on classical interfaces of a classical programming language (C in this case). To complicate matters (or rather, to generalize), a simple high frequency communication cycle of A to G and back (IOW: A is rapidly polling G) is out of focus because of technical restrictions (delay of serial com, A not always active, etc.). What I currently see as a general solution is: the application logic A as one thread of execution an adapter object (proxy) PG (presenting G inside the computer), together with the serial driver as another thread a communication object between the two (A and PG) which is transactionally safe to exchange The two execution contexts (threads) on the computer may be multi-core or just interrupt driven or tasks in an RTOS. The com object contains the following data: suspected state (written by A): effectively a member of the power set of states in G (in our case: red, green, blue, off, red_or_green, red_or_blue, red_or_off...etc.) command data (written by A): test_if_off, switch_to_red, switch_to_green, switch_to_blue operation status (written by PG): operation_pending, success, wrong_state, link_broken new state (written by PG): red, green, blue, off The idea of the com object is that A writes whichever (set of) state it thinks G is in, together with a command. (Example: suspected state="red_or_green", command: "switch_to_blue") Notice that the commands issued by A will not work if the user has switched off the LED and A needs to know this. PG will pick up such a com object and try to send the command to G, receive its answer (or a timeout) and set the operation status and new state accordingly. A will take back the oject once it is no longer at operation_pending and can react to the outcome. The com object could be separated of course (into two objects, one for each direction) but I think it is convenient in nearly all instances to have the command close to the result. I would like to have major flaws pointed out or hear an entirely different view on such a situation.

    Read the article

< Previous Page | 15 16 17 18 19 20 21 22 23 24 25 26  | Next Page >