Search Results

Search found 2899 results on 116 pages for 'rate limiting'.

Page 19/116 | < Previous Page | 15 16 17 18 19 20 21 22 23 24 25 26  | Next Page >

  • Slow Windows Explorer on Windows 7

    - by MadBoy
    I have Laptop with i7 (4 cores), 8GB ram and SSD OCZ Vertex 3 MaxIOPS which in testing that I did just now does 400mb/s+ read/write. However the responsiveness of Windows Explorer is far from being perfect. Opening up Computer, Documents, going into folders is very slow (1-5seconds). I don't have any viruses or spyware and I have tried changing properties to optimize view for General Items. I tried disabling Search Indexer but it made search in Outlook 2010 crawl and didn't bring any other effect. Even double clicking on file takes some time to open things up (like clicking a Word document). I don't have any drives mapped, my computer is not joined to domain. I have multiple VPN connections that I connect to but they all have disabled default gateways. I tried using CC Cleaner or some Windows 7 Tweaks app to disable some things. I am power user using Visual Studio, Tortoise SVN and other developer/administration apps. Any non obvious ideas? Edit: So I've been trying to pinpoint where the issue comes from and it seems that straight after reboot Windows Explorer opens very fast, when I load 3-4 programs (Royal TS, Visual Studio, Outlook) it's noticeably slower and the more programs I have it gets worse. After I start closing programs it starts working better and if I leave 2 open it's fast again. I tried doing some research with DiskMon and other programs from sysinternals but couldn't find anything suspicious. Below are stats during normal usage with a lots of programs open: - Ram usage with a lot of programs open and no swap file (i disabled it for testing): 6.95GB - CPU usage: 15%, none of the cores takes more then 50% (I have VS 2010 open x 4) HD Tune Pro: OCZ-VERTEX3 MI Benchmark Test capacity: full Read transfer rate Transfer Rate Minimum : 363.9 MB/s Transfer Rate Maximum : 505.5 MB/s Transfer Rate Average : Access Time : Burst Rate : CPU Usage : HD Tune Pro: OCZ-VERTEX3 MI File Benchmark Drive C: Transfer rate test File Size: 500 MB Sequential read 484102 KB/s Sequential write 444714 KB/s Random read 7779 IOPS Random write 16888 IOPS Random read (queue depth = 32) 73007 IOPS Random write (queue depth = 32) 69790 IOPS HD Tune Pro: OCZ-VERTEX3 MI Random Access Test capacity: full Read test Transfer size operations / sec avg. access time max. access time avg. speed 512 bytes 3260 IOPS 0.306 ms 2.106 ms 1.592 MB/s 4 KB 4161 IOPS 0.240 ms 2.006 ms 16.256 MB/s 64 KB 2382 IOPS 0.419 ms 2.367 ms 148.934 MB/s 1 MB 449 IOPS 2.225 ms 4.197 ms 449.407 MB/s Random 809 IOPS 1.235 ms 6.551 ms 410.527 MB/s HD Tune Pro: OCZ-VERTEX3 MI Extra Tests Test capacity: full Random seek 3975 IOPS 0.252 ms 1.941 MB/s Random seek 4 KB 4245 IOPS 0.236 ms 16.583 MB/s Butterfly seek 4086 IOPS 0.245 ms 1.995 MB/s Random seek / size 64 KB 3812 IOPS 0.262 ms 58.606 MB/s Random seek / size 8 MB 120 IOPS 8.348 ms 485.737 MB/s Sequential outer 4524 IOPS 0.221 ms 282.721 MB/s Sequential middle 4429 IOPS 0.226 ms 276.818 MB/s Sequential inner 5504 IOPS 0.182 ms 344.000 MB/s Burst rate 4472 IOPS 0.224 ms 279.475 MB/s

    Read the article

  • Which has a faster data transfer rate? WIFI (tablet or cell phone, not LTE) or MicroSD (Class 10)?

    - by techaddict
    Which of the two methods of dta transfer trasfers data at a faster rate for smartphones and tablets? Standard WIFI, or MicroSD Cards? I wonder if it would be actually faster to access data on external storage then it would be to have the MicroSD card in my smartphone or tablet. Currently I have a class 10 32GB MicroSD card in my cell phone. I am looking to get the new Google Nexus tablet but it does not offer expandable internal storage. I wonder if that's really a detriment; because if WIFI is faster than MicroSD, then it would matter almost none at all that you couldn't expand the storage internally. If the case is that WIFI is faster, and people caught onto this, then people could save a lot of money on lower memory ipads/iphones/ipods, tablets, and smartphones!

    Read the article

  • passing values to php print page

    - by DAFFODIL
    In this wen i select a value in drop down box it will list out that name value in table .There will be a check box ,the checked values should be passed to pring page which is below the 1st part of code. Any help ii be appreciated <?php $con = mysql_connect("localhost","root",""); if (!$con) { die('Could not connect: ' . mysql_error()); } mysql_select_db("form1", $con); error_reporting(E_ALL ^ E_NOTICE); $nam=$_REQUEST['select1']; $row=mysql_query("select * from inv where name='$nam'"); while($row1=mysql_fetch_array($row)) { $Name=$row1['Name']; $Address =$row1['Address']; $City=$row1['City']; $Pincode=$row1['Pincode']; $No=$row1['No']; $Date=$row1['Date']; $DCNo=$row1['DCNo']; $DcDate=$row1['DcDate']; $YourOrderNo=$row1['YourOrderNo']; $OrderDate=$row1['OrderDate']; $VendorCode=$row1['VendorCode']; $SNo=$row1['SNo']; $descofgoods=$row1['descofgoods']; $Qty=$row1['Qty']; $Rate=$row1['Rate']; $Amount=$row1['Amount']; } ?> <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml"> <head> <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1" /> <title>Untitled Document</title> <script type="text/javascript"> function ram() { var q=document.getElementById('qty').value; var r=document.getElementById('rate').value; document.getElementById('amt').value=q*r; } </script> </head> <body> <form id="form1" name="form1" method="post" action=""> <table width="1315" border="0"> <script type="text/javascript"> function g() { form1.submit(); } </script> <tr> <th>Name</th> <th align="left"><select name="select1" onchange="g();"> <option value="" selected="selected">select</option> <?php $row=mysql_query("select Name from inv "); while($row1=mysql_fetch_array($row)) { ?> <option value="<?php echo $row1['Name'];?>"><?php echo $row1['Name'];?></option> <?php } ?> </select></th> </tr> <tr> <th>Address</th> <th align="left"><textarea name="Address"><?php echo $Address;?></textarea></th> </tr> <tr> <th>City</th> <th align="left"><input type="text" name="City" value='<?php echo $City;?>' /></th> </tr> <tr> <th>Pincode</th> <th align="left"><input type="text" name="Pincode" value='<?php echo $Pincode;?>'></th> </tr> <tr> <th>No</th> <th align="left"><input type="text" name="No2" value='<?php echo $No;?>' readonly="" /></th> </tr> <tr> <th>Date</th> <th align="left"><input type="text" name="Date" value='<?php echo $Date;?>' readonly="" /></th> </tr> <tr> <th>DCNo</th> <th align="left"><input type="text" name="DCNo" value='<?php echo $DCNo;?>' readonly="" /></th> </tr> <tr> <th>DcDate:</th> <th align="left"><input type="text" name="DcDate" value='<?php echo $DcDate;?>' /></th> </tr> <tr> <th>YourOrderNo</th> <th align="left"><input type="text" name="YourOrderNo" value='<?php echo $YourOrderNo;?>' readonly="" /></th> </tr> <tr> <th>OrderDate</th> <th align="left"><input type="text" name="OrderDate" value='<?php echo $OrderDate;?>' readonly="" /></th> </tr> <tr> <th width="80">VendorCode</th> <th width="1225" align="left"><input type="text" name="VendorCode" value='<?php echo $VendorCode;?>' readonly="" /></th> </tr> </table> <table width="1313" border="0"> <tr> <td width="44">&nbsp;</td> <td width="71">SNO</td> <td width="527">DESCRIPTION</td> <td width="214">QUANTITY</td> <td width="214">RATE/UNIT</td> <td width="217">AMOUNT</td> </tr> <?php $i=1; $row=mysql_query("select * from inv where Name='$nam'"); while($row1=mysql_fetch_array($row)) { $descofgoods=$row1['descofgoods']; $Qty=$row1['Qty']; $Rate=$row1['Rate']; $Amount=$row1['Amount']; ?> <tr> <td><input type="checkbox" name="checkbox" value="checkbox" /></td> <td><input type="text" name="No" value='<?php echo $No;?>' readonly=""/></td> <td><input type="text" name="descofgoods" value='<?php echo $descofgoods;?>' /></td> <td><input type="text" name="qty" maxlength="50000000" id="qty"/></td> <td><input type="text" name="Rate" value='<?php echo $Rate;?>' id="rate" onclick="ram()";></td> <td><input type="text" name="Amount" id="amt"/></td> </tr> <?php $i++;} ?> <tr> <th colspan="2"><a href="pp.php?msg=<?php echo $nam;?>">Print</a></th> </tr> </table> <label></label> </form> </body> </html> - <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml"> <head> <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1" /> <title></title> <script type = "text/javascript"> function a() { var q = document.getElementsByName('Amount'); var count = 0; for (i = 0; i < q.length; i++) count += parseInt(q[i].value,10); document.getElementById('s').value = count; } </script> </head> <?php $con = mysql_connect("localhost","root",""); if (!$con) { die('Could not connect: ' . mysql_error()); } mysql_select_db("form1", $con); error_reporting(E_ALL ^ E_NOTICE); $nam=$_GET['msg']; $row=mysql_query("select * from inv where Name='$nam'"); while($row1=mysql_fetch_array($row)) { $Name=$row1['Name']; $Address =$row1['Address']; $City=$row1['City']; $Pincode=$row1['Pincode']; $No=$row1['No']; $Date=$row1['Date']; $DCNo=$row1['DCNo']; $DcDate=$row1['DcDate']; $YourOrderNo=$row1['YourOrderNo']; $OrderDate=$row1['OrderDate']; $VendorCode=$row1['VendorCode']; $SNo=$row1['SNo']; $descofgoods=$row1['descofgoods']; $Qty=$row1['Qty']; $Rate=$row1['Rate']; $Amount=$row1['Amount']; } ?> <body> <form id="form1" name="form1" method="post" action=""> <table width="846" border="0"> <tr> <td width="411" height="113">&nbsp;</td> <td width="412">&nbsp;</td> </tr> </table> <table width="846" border="0"> <tr> <td height="38">&nbsp;</td> </tr> </table> <table width="846" border="0"> <tr> <td width="390" rowspan="4">&nbsp;</td> <td width="92" height="35">&nbsp;</td> <td width="136"><?php echo $No;?></td> <td width="36">&nbsp;</td> <td width="170"><?php echo $Date;?></td> </tr> <tr> <td height="37">&nbsp;</td> <td><?php echo $DCNo;?></td> <td>&nbsp;</td> <td><?php echo $DcDate;?></td> </tr> <tr> <td height="34">&nbsp;</td> <td><?php echo $YourOrderNo;?></td> <td>&nbsp;</td> <td><?php echo $OrderDate;?></td> </tr> <tr> <td height="29">&nbsp;</td> <td><?php echo $VendorCode;?></td> <td>&nbsp;</td> <td>&nbsp;</td> </tr> </table> <table width="845" border="0"> <tr> <td height="38">&nbsp;</td> <td>&nbsp;</td> <td>&nbsp;</td> <td>&nbsp;</td> <td>&nbsp;</td> </tr> <tr> <td width="34">&nbsp;</td> <td width="457">&nbsp;</td> <td width="104">&nbsp;</td> <td width="79">&nbsp;</td> <td width="149">&nbsp;</td> </tr> <?php $i=1; $row=mysql_query("select * from inv where Name='$nam'"); while($row1=mysql_fetch_array($row)) { $descofgoods=$row1['descofgoods']; $Qty=$row1['Qty']; $Rate=$row1['Rate']; $Amount=$row1['Amount']; ?> <tr> <td><?php echo $i;?></td> <td><?php echo $descofgoods;?></td> <td><?php echo $Qty;?></td> <td><?php echo $Rate;?></td> <td><input name="Amount" type = "text" value="<?php echo $Amount; ?>" /></td> </tr> <?php $i++;} ?> </table> <table width="844" border="0"> <tr> <td width="495" height="1065">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <input type="text" name="textfield2" width="150" /> &nbsp; &nbsp; &nbsp; &nbsp; </td> <td width="191">&nbsp;</td> <td width="144"><input type="text" name="to" id="s" onclick="a()";/></td> </tr> </table> </form> </body> </html>

    Read the article

  • Detect and record a sound with python

    - by Jean-Pierre
    I'm using this program to record a sound in python: import pyaudio import wave import sys chunk = 1024 FORMAT = pyaudio.paInt16 CHANNELS = 1 RATE = 44100 RECORD_SECONDS = 5 WAVE_OUTPUT_FILENAME = "output.wav" p = pyaudio.PyAudio() stream = p.open(format = FORMAT, channels = CHANNELS, rate = RATE, input = True, frames_per_buffer = chunk) print "* recording" all = [] for i in range(0, RATE / chunk * RECORD_SECONDS): data = stream.read(chunk) all.append(data) print "* done recording" stream.close() p.terminate() write data to WAVE file data = ''.join(all) wf = wave.open(WAVE_OUTPUT_FILENAME, 'wb') wf.setnchannels(CHANNELS) wf.setsampwidth(p.get_sample_size(FORMAT)) wf.setframerate(RATE) wf.writeframes(data) wf.close() I want to change the program to start recording when sound is detected by the sound card input. Probably should compare the input sound level in Chunk, but how do this?

    Read the article

  • JPA : Inheritance - Discriminator value not taken into account in generated SQL

    - by Julien
    I try to use this mapping : @Entity @Table(name="ecc.\"RATE\"") @Inheritance(strategy=InheritanceType.SINGLE_TABLE) @DiscriminatorColumn(name="DISCRIMINATOR", discriminatorType= DiscriminatorType.STRING) public abstract class Rate extends GenericBusinessObject { ... } @Entity @DiscriminatorValue("E") public class EntranceRate extends Rate { @ManyToOne @JoinColumn(name = "\"RATES_GRID_ID\"") protected RatesGrid ratesGrid; ... } @Entity @Table(name="ecc.\"RATES_GRID\"") public class RatesGrid extends GenericBusinessObject { /** */ @OneToMany(mappedBy = "ratesGrid", targetEntity = EntranceRate.class, fetch=FetchType.LAZY) private List<EntranceRate> entranceRates; } When I try to access my entranceRates list from a ratesGrid object, I get this error : Object with id: 151 was not of the specified subclass: com.ecc.bo.rate.EntranceRate (loaded object was of wrong class class com.ecc.bo.rate.AnnualRate) Looking at the sql generated, I found no trace of "discriminator=" in the where clause. What am I doing wrong ? I use a PostGreSQL database and a Hibernate as JPA provider.

    Read the article

  • Read specific div from HttpResponse

    - by Kishan Gajjar
    I am sending 1 httpWebRequest and reading the response. I am getting full page in the response. I want to get 1 div which is names ad Rate from the response. So how can I match that pattern? My code is like: HttpWebRequest WebReq = (HttpWebRequest)WebRequest.Create("http://www.domain.com/"); HttpWebResponse WebResp = (HttpWebResponse)WebReq.GetResponse(); Stream response = WebResp.GetResponseStream(); StreamReader data = new StreamReader(response); string result = data.ReadToEnd(); I am getting response like: <HTML><BODY><div id="rate">Todays rate 55 Rs.</div></BODY></HTML> I want to read data of div rate. i.e. I should get Content "Todays rate 55 Rs." So how can I make regex for this???

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Decimal problem in Java

    - by Jerome
    I am experimenting with writing a java class for financial engineering (hobby of mine). The algorithm that I desire to implement is: 100 / 0.05 = 2000 Instead I get: 100 / 0.05 = 2000.9999999999998 I understand the problem to be one with converting from binary numbers to decimals (float -- int). I have looked at the BigDecimal class on the web but have not quite found what I am looking for. Attached is the program and a class that I wrote: // DCF class public class DCF { double rate; double principle; int period; public DCF(double $rate, double $principle, int $period) { rate = $rate; principle = $principle; period = $period; } // returns the console value public double consol() { return principle/rate; } // to string Method public String toString() { return "(" + rate + "," + principle + "," + period + ")"; } } Now the actual program: // consol program public class DCFmain { public static void main(String[] args) { // create new DCF DCF abacus = new DCF(0.05, 100.05, 5); System.out.println(abacus); System.out.println("Console value= " + abacus.consol() ); } } Output: (0.05,100.05,5) Console value= 2000.9999999999998 Thanks!

    Read the article

  • Run multiple MySQL queries based on a series of ifs

    - by OldWest
    I am just getting started on this complex query I need to write and was hoping for any suggestions or feedback regarding table structure and the actual query itself.. I've already created my tables and populated test data, and now just trying to sort out how and what is possible within MySQL. Here is an outline of the problem: End result: Listing of rates based on specific queried criteria (see below): Age: [ 27 ] Spouse Age: [ 25 ] Num of Children: [ 3 ] Zip Code: [ 97128 ] The problem I am running into is each company that provides rates has a unique way of dealing with the rate. And I am looking for the best approach for multiple queries based on the company (one query with results for each company more or less all combined into one result set). Here are some facts: - Each company deals with zip code ranges which assist in the query result. - Each company has a different method of calculating the rate based on the Applicant, Spouse, Num of Children: Example, a) Company A determines rate by: Applicant + Spouse + Child(ren) = rate (age is pertinent to the applicant within a range). b) Company B determines the rate by total number of applicants like: 1, 2, 3, 4, 5, 6+ = rate (and age is ignored). First off, what would I call this type of query? Multiple nested query? And should I intertwine php within it to determine the If()s ... I apologize if this thread lacks sufficient data, so please tell me anything you would like to see.

    Read the article

  • Xml output on HTML

    - by umitunal
    Hi, My xml data = &lt;Item "/api/items/4000000002011"&gt;&lt;ItemID&gt;4000000002011&lt;/ItemID&gt;&lt;Name&gt;Sample Item1&lt;/Name&gt;&lt;Description&gt;Sample Description&lt;/Description&gt;&lt;Rate&gt;34.00&lt;/Rate&gt;&lt;Tax1Name&gt;PST&lt;/Tax1Name&gt;&lt;Tax1Percentage&gt;8&lt;/Tax1Percentage&gt;&lt;Tax2Name/&gt;&lt;Tax2Percentage/&gt;&lt;/Item&gt; Html output=<Item uri="/api/items/4000000002011"> <ItemID>4000000002011</ItemID><Name>Sample Item1</Name><Description>Sample Description</Description><Rate>34.00</Rate><Tax1Name>PST</Tax1Name><Tax1Percentage>8</Tax1Percentage><Tax2Name/><Tax2Percentage/></Item> I want to html output.How do I? <Item "/api/items/4000000002011"> <ItemID>4000000002011</ItemID> <Name>Sample Item1</Name> <Description>Sample Description</Description> <Rate>34.00</Rate> <Tax1Name>PST</Tax1Name> <Tax1Percentage>8</Tax1Percentage> <Tax2Name/> <Tax2Percentage/> </Item>

    Read the article

  • How to get tens of millions of pages indexed by Google bot?

    - by Chris Adragna
    We are currently developing a site that currently has 8 million unique pages that will grow to about 20 million right away, and eventually to about 50 million or more. Before you criticize... Yes, it provides unique, useful content. We continually process raw data from public records and by doing some data scrubbing, entity rollups, and relationship mapping, we've been able to generate quality content, developing a site that's quite useful and also unique, in part due to the breadth of the data. It's PR is 0 (new domain, no links), and we're getting spidered at a rate of about 500 pages per day, putting us at about 30,000 pages indexed thus far. At this rate, it would take over 400 years to index all of our data. I have two questions: Is the rate of the indexing directly correlated to PR, and by that I mean is it correlated enough that by purchasing an old domain with good PR will get us to a workable indexing rate (in the neighborhood of 100,000 pages per day). Are there any SEO consultants who specialize in aiding the indexing process itself. We're otherwise doing very well with SEO, on-page especially, besides, the competition for our "long-tail" keyword phrases is pretty low, so our success hinges mostly on the number of pages indexed. Our main competitor has achieved approx 20MM pages indexed in just over one year's time, along with an Alexa 2000-ish ranking. Noteworthy qualities we have in place: page download speed is pretty good (250-500 ms) no errors (no 404 or 500 errors when getting spidered) we use Google webmaster tools and login daily friendly URLs in place I'm afraid to submit sitemaps. Some SEO community postings suggest a new site with millions of pages and no PR is suspicious. There is a Google video of Matt Cutts speaking of a staged on-boarding of large sites, too, in order to avoid increased scrutiny (at approx 2:30 in the video). Clickable site links deliver all pages, no more than four pages deep and typically no more than 250(-ish) internal links on a page. Anchor text for internal links is logical and adds relevance hierarchically to the data on the detail pages. We had previously set the crawl rate to the highest on webmaster tools (only about a page every two seconds, max). I recently turned it back to "let Google decide" which is what is advised.

    Read the article

  • Queston about torrents

    - by c0mrade
    Why do my torrents go at rate 25/30 kb/s and my regular http downloads rate up to 300 kb/s .. is my ISP to blame for this, I meant torrents have like thousand seeders and again its very slow.How are they blocking torrent speed, can I bypass it? @gekkz Results : * There's no indication that your ISP rate limits all downloads at port 6881. In our test, a TCP download on a BitTorrent port achieved at least 392 Kbps while a TCP download on a non-BitTorrent port achieved at least 223 Kbps. You can find details here. * There's no indication that your ISP rate limits all uploads at port 6881. In our test, a TCP upload on a BitTorrent port achieved at least 314 Kbps while a TCP upload on a non-BitTorrent port achieved at least 191 Kbps. You can find details here.

    Read the article

  • Block Google requests to 16k using pf firewall

    - by atmosx
    I'd like to block access to Google search using PF after the threshold of 17500 requests (connection established) in 24h, from a host running FreeBSD 9. What I came up with, after reading pf-faq is this rule: pass out on $net proto tcp from any to 'www.google.com' port www flags S/SA keep state (max-src-conn 200, max-src-conn-rate 17500/86400) NOTE: 86400 are 24h in seconds. The rule should work, but PF is smart enough to know that www.google.com resolves in 5 different IPs. So my pfctl -sr output gives me this: pass out on vte0 inet proto tcp from any to 173.194.44.81 port = http flags S/SA keep state (source-track rule, max-src-conn 200, max-src-conn-rate 17500/86400, src.track 86400) pass out on vte0 inet proto tcp from any to 173.194.44.82 port = http flags S/SA keep state (source-track rule, max-src-conn 200, max-src-conn-rate 17500/86400, src.track 86400) pass out on vte0 inet proto tcp from any to 173.194.44.83 port = http flags S/SA keep state (source-track rule, max-src-conn 200, max-src-conn-rate 17500/86400, src.track 86400) pass out on vte0 inet proto tcp from any to 173.194.44.80 port = http flags S/SA keep state (source-track rule, max-src-conn 200, max-src-conn-rate 17500/86400, src.track 86400) pass out on vte0 inet proto tcp from any to 173.194.44.84 port = http flags S/SA keep state (source-track rule, max-src-conn 200, max-src-conn-rate 17500/86400, src.track 86400) PF creates 5 different rules, 1 for each IP that Google resolves. However I have the sense - without being 100% sure, I didn't had the chance to test it - that the number 17500/86400 applies for each IP. If that's the case - please confirm - then it's not what I want. In pf-faq there's another option called source-track-global: source-track This option enables the tracking of number of states created per source IP address. This option has two formats: + source-track rule - The maximum number of states created by this rule is limited by the rule's max-src-nodes and max-src-states options. Only state entries created by this particular rule count toward the rule's limits. + source-track global - The number of states created by all rules that use this option is limited. Each rule can specify different max-src-nodes and max-src-states options, however state entries created by any participating rule count towards each individual rule's limits. The total number of source IP addresses tracked globally can be controlled via the src-nodes runtime option. I tried to apply source-track-global in the above rule without success. How can I use this option in order to achieve my goal? Any thoughts or comments are more than welcome since I'm an amateur and don't fully understand PF yet. Thanks

    Read the article

  • How to prioritize openvpn traffic?

    - by aditsu
    I have an openvpn server, with one network interface. VPN traffic is extremely slow. I tried to do traffic control with this configuration (currently): qdisc del dev eth0 root qdisc add dev eth0 root handle 1: htb default 12 class add dev eth0 parent 1: classid 1:1 htb rate 900mbit #vpn class add dev eth0 parent 1:1 classid 1:10 htb rate 1500kbit ceil 3000kbit prio 1 #local net class add dev eth0 parent 1:1 classid 1:11 htb rate 10mbit ceil 900mbit prio 2 #other class add dev eth0 parent 1:1 classid 1:12 htb rate 500kbit ceil 1000kbit prio 2 filter add dev eth0 protocol ip parent 1:0 prio 1 u32 match ip sport 1194 0xffff flowid 1:10 filter add dev eth0 protocol ip parent 1:0 prio 2 u32 match ip dst 192.168.10.0/24 flowid 1:11 qdisc add dev eth0 parent 1:10 handle 10: sfq perturb 10 qdisc add dev eth0 parent 1:11 handle 11: sfq perturb 10 qdisc add dev eth0 parent 1:12 handle 12: sfq perturb 10 But it's still extremely slow. I have an imaps connection that keeps transferring data continuously (I successfully limited the rate) but with openvpn I can't seem to get more than about 100kbit/s The internet connection speed is about 3mbit/s (symmetric) What could be the problem? Does the sport filter work for udp?

    Read the article

  • iis7 bandwith throttling for downloads via iis media services?

    - by MikeJ
    I am looking after a sever that is managing the downloads of software updates released by the company where I work. The throttle in IIS7 seems to limit the total rate and not the rate each individual download gets. I was thnking on installing media services, adding .zip as a type and then throttling the individual connection rate based on what I read. Is this how this sort of thing is done with IIS7?

    Read the article

  • How to prioritize openvpn traffic?

    - by aditsu
    I have an openvpn server, with one network interface. VPN traffic is extremely slow. I tried to do traffic control with this configuration (currently): qdisc del dev eth0 root qdisc add dev eth0 root handle 1: htb default 12 class add dev eth0 parent 1: classid 1:1 htb rate 900mbit #vpn class add dev eth0 parent 1:1 classid 1:10 htb rate 1500kbit ceil 3000kbit prio 1 #local net class add dev eth0 parent 1:1 classid 1:11 htb rate 10mbit ceil 900mbit prio 2 #other class add dev eth0 parent 1:1 classid 1:12 htb rate 500kbit ceil 1000kbit prio 2 filter add dev eth0 protocol ip parent 1:0 prio 1 u32 match ip sport 1194 0xffff flowid 1:10 filter add dev eth0 protocol ip parent 1:0 prio 2 u32 match ip dst 192.168.10.0/24 flowid 1:11 qdisc add dev eth0 parent 1:10 handle 10: sfq perturb 10 qdisc add dev eth0 parent 1:11 handle 11: sfq perturb 10 qdisc add dev eth0 parent 1:12 handle 12: sfq perturb 10 But it's still extremely slow. I have an imaps connection that keeps transferring data continuously (I successfully limited the rate) but with openvpn I can't seem to get more than about 100kbit/s The internet connection speed is about 3mbit/s (symmetric) What could be the problem? Does the sport filter work for udp?

    Read the article

  • tc rules block traffic from some hosts at network

    - by user139430
    I have a problem I can not solve. The script, which sets the rules for traffic shaping is blocking the traffic from some hosts.If I remove all the rules, then it works. I can not understand why? Here is my script... #!/bin/sh cmdTC=/sbin/tc rateLANDl="60mbit" ceilLANDl="60mbit" rateLANUl="40mbit" ceilLANUl="40mbit" quantLAN="1514" # Nowaday bandwidth limit set to 100mbit. # We devide it with 60mbit download and 40mbit upload bandthes. rateHiDl="30mbit" ceilHiDl="60mbit" rateHiUl="20mbit" ceilHiUl="40mbit" quantHi="1514" rateLoDl="30mbit" ceilLoDl="60mbit" rateLoUl="20mbit" ceilLoUl="40mbit" quantLo="1514" devNIF=eth0 devFIF=ifb0 modprobe ifb ip link set $devFIF up 2>/dev/null #exit 0 ################################################################################################ # Remove discuiplines from network and fake interfaces ################################################################################################ $cmdTC qdisc del dev $devNIF root 2>/dev/null $cmdTC qdisc del dev $devFIF root 2>/dev/null $cmdTC qdisc del dev $devNIF ingress 2>/dev/null if [ "$1" = "down" ]; then exit 0 fi ################################################################################################ # Create discuiplines for network interface ################################################################################################ $cmdTC qdisc add dev $devNIF root handle 1:0 htb default 12 # Create classes for network interface $cmdTC class add dev $devNIF parent 1:0 classid 1:1 htb rate ${rateLANDl} ceil ${ceilLANDl} quantum ${quantLAN} $cmdTC class add dev $devNIF parent 1:1 classid 1:11 htb rate ${rateHiDl} ceil ${ceilHiDl} quantum ${quantHi} $cmdTC class add dev $devNIF parent 1:1 classid 1:12 htb rate ${rateLoDl} ceil ${ceilLoDl} quantum ${quantLo} $cmdTC qdisc add dev $devNIF parent 1:11 handle 111: sfq perturb 10 $cmdTC qdisc add dev $devNIF parent 1:12 handle 112: sfq perturb 10 # Create filters for network interface $cmdTC filter add dev $devNIF protocol all parent 1:0 u32 match ip dst 10.252.2.0/24 flowid 1:11 $cmdTC filter add dev $devNIF protocol all parent 111: handle 111 flow hash keys dst divisor 1024 baseclass 1:11 $cmdTC filter add dev $devNIF protocol all parent 112: handle 112 flow hash keys dst divisor 1024 baseclass 1:12 ################################################################################################ # Create discuiplines for fake interface ################################################################################################ $cmdTC qdisc add dev $devFIF root handle 1:0 htb default 12 # Create classes for network interface $cmdTC class add dev $devFIF parent 1:0 classid 1:1 htb rate ${rateLANUl} ceil ${ceilLANUl} quantum ${quantLAN} $cmdTC class add dev $devFIF parent 1:1 classid 1:11 htb rate ${rateHiUl} ceil ${ceilHiUl} quantum ${quantHi} $cmdTC class add dev $devFIF parent 1:1 classid 1:12 htb rate ${rateLoUl} ceil ${ceilLoUl} quantum ${quantLo} $cmdTC qdisc add dev $devFIF parent 1:11 handle 111: sfq perturb 10 $cmdTC qdisc add dev $devFIF parent 1:12 handle 112: sfq perturb 10 # Create filters for network interface $cmdTC filter add dev $devFIF protocol all parent 1:0 u32 match ip src 10.252.2.0/24 flowid 1:11 $cmdTC filter add dev $devFIF protocol all parent 111: handle 111 flow hash keys src divisor 1024 baseclass 1:11 $cmdTC filter add dev $devFIF protocol all parent 112: handle 112 flow hash keys src divisor 1024 baseclass 1:12 ################################################################################################ # Create redirect discuiplines from network to fake interface ################################################################################################ $cmdTC qdisc add dev $devNIF handle ffff:0 ingress $cmdTC filter add dev $devNIF parent ffff:0 protocol all u32 match u32 0 0 action mirred egress redirect dev $devFIF Here is my /etc/modules: loop ifb ppp_mppe nf_conntrack_pptp nt_conntrack_proto_gre nf_nat_pptp nf_nat_proto_gre The system is Linux wall 2.6.32-5-amd64 #1 SMP Sun Sep 23 10:07:46 UTC 2012 x86_64 GNU/Linux

    Read the article

  • computer plays movie fine but ps3 plays it with no sound?

    - by kacalapy
    i have a movie that plays fine on my computer but when i copy it to an SD card and play it in my PS3 it has no sound. the audio format is mpeg layer-3 bit rate is 128 frame rate is 25frames/ second data rate is 1068 kbps video sample size is 12 bit video compression is DivX i got these stats by right clicking the file and viewing properties. can i open it in some editor and re-save it? what editor? thanks all

    Read the article

  • RAID 6 that can read with least 1000 Mbit/s?

    - by Diblo Dk
    I purchased a Dell PERC 6/i which I expected to be able to read with 1000 Mbps. There is not much to do now, but there are some things I wanted knowledge about for another time. I have configured it with four 2 TByte drives and RAID 6. It have 256 MByt ram and transfer rate of 300 Mbps. The benchmark test showed: Min read rate: 136.3 Mbps Max read rate: 329,6 Mbps Avg read rate: 242,2 Mbps What could I had done to get at least 1000 Mbps? Is it normal for internal and external RAID controllers to have a lower transfer rate eg. 300 Mbps? (I did not noticed at the time that it was not 3 Gbps) How would a RAID 10 had performed compared to RAID 6 or 5? Would it have been better to use software RAID (Linux) with the internal 3 Gbps SATA controller? UPDATE: The drives is SATA III 6 Gbps. http://www.seagate.com/files/staticfiles/docs/pdf/datasheet/disc/desktop-hdd-data-sheet-ds1770-1-1212us.pdf (2TB)

    Read the article

  • Why does HDTune report better performing drives 2 months after installing them?

    - by Rolnik
    OK, so this is really weird. I ran HDTune on a newly set-up home-built computer and got the following readings from my drives in mid-November. SSD 154 MB/s RAID1 87 RAID0 198 (software installs) RAID0 98 Swap drive Today, in January, I run HDTune (same version) and get these results, in MB/s: SSD 186 RAID1 98 RAID0 241 RAID0 98 (Swap drive) Here are more details that HDTune reports on the SSD drive: HD Tune: OCZ-VERTEX Benchmark Blockquote Transfer Rate Minimum : 135.4 MB/sec Transfer Rate Maximum : 219.4 MB/sec Transfer Rate Average : 185.7 MB/sec Access Time : 0.1 ms Burst Rate : 187.3 MB/sec CPU Usage : -1.0% To get to my question: Why are my hard drives improving in performance? Most of my logical drives are in some form of RAID, except for the SSD. Will this performance ever deteriorate? Note, none of my drives are a hybrid drive that uses some form of SSD to enhance the write/reads on actual platters.

    Read the article

  • Need help in creating test appliaction in Java and passing parameters into a new designed Java API.

    - by Christophe
    Need help, Please!!! By following the protocol, the Request should be built in 5 byte length, including 1 byte for changing Braud rate (Speed), and send request to a RS-232 port. Protocol: --------------- Request for the command processing, with optional extra byte for changing Baud Rate: LGT : length message ( LGT = 5 ) TYPE : 0x06 TO(time out): 0x0000 CMD : (1 byte) 0x02 application update Baud Rate : (1 byte) 0xNN (optional parameter to change baud rate of the Mnt App) where NN can be: 0x00 = No Baud Rate Change (similar to 4-byte command above) 0x09 = Change to 9600 Baud for Application Update speed 0x0A = Change to 19200 Baud for Application Update speed 0x0E = Change to 115200 Baud for Application Update speed All other bytes are not accepted and will result in a status of 0x01. ------------------ I'm trying to test if my code works or not by creating another class (TestApplication.java) and pass the "3 differenr Baut rate" to this CPXAppliaction. the 3 Baud Rate is supposed to input by reading a file.txt. Question: How do you think these code (first half)? please don't warry about the details about the "sending part". I mean, do I need setter/getter for the "speed" parameter pass? I created the demo test class DemoApp.java (input speed by reading a txt file, and pass into CPXAppliaction). how do you think about that code? Many thanks to you guys!! public class CPXApplication extends CPXCommand { private int speed; . public CPXApplication() { speed = 9600; } public CPXApplication(int speedinit) { speed = speedinit; // TODO: where to get the speed? } protected void buildRequest() throws ElitePortException { String trans = ""; // build the full-qualified message following the protocol trans = addToRequest(trans, (char) 0); trans = addToRequest(trans, (char) 5); trans = addToRequest(trans, (char) 6); trans = addToRequest(trans, (char) 0); trans = addToRequest(trans, (char) 0); trans = addToRequest(trans, (char) 2); switch (speed) { case 9600: trans = addToRequest(trans, (char) 0x09); break; case 19200: trans = addToRequest(trans, (char) 0x0A); break; case 115200: trans = addToRequest(trans, (char) 0x0E); break; default: // TODO: unexpected baud rate. throw(); break; } trans = EncryptBinary(trans); trans = "F0." + trans; wrapRequest(trans); } protected String addToRequest(String req, char c) { return req + c; } protected String addToRequest(String req, String s) { return req + s; } protected String addToRequest(String req) { return req; } public void analyzeResponse() { //.............. } } Here is the demo test code: package com.ingenico.testApp; import com.ingenico.EliteFd.; import java.util.Scanner; import java.io.; class Run { public static void run() { CPXAppliactionUpdate input = new CpXApplicationUpdate(); int lineno = 0; try { FileReader fr = new FileReader("baudRateSpeed.txt"); BufferedReader reader = new BufferedReader(fr); String line = reader.readLine(); Scanner scan = null; while (line != null) { scan = new Scanner(line); String speed; speed = scan.next(); if (lineno == 0) { input.speed = speed; lineno++; } else { input = cpxapplicationupdate(speed, input); } line = reader.readLine(); } reader.close(); } catch (FileNotFoundException e) { System.out.println("Could not find the file"); } catch (IOException e) { System.out.println("Had a problem reading from file"); } } public class DemoApp{ public void main(String args[]) { run(); } } }

    Read the article

  • Need help in creating test application in Java and passing parameters into a new designed Java API.

    - by Christophe
    Need help, Please!!! By following the protocol, the Request should be built in 5 byte length, including 1 byte for changing Braud rate (Speed), and send request to a RS-232 port. Protocol: Request for the command processing, with optional extra byte for changing Baud Rate: LGT : length message ( LGT = 5 ) TYPE : 0x06 TO(time out): 0x0000 CMD : (1 byte) 0x02 application update Baud Rate : (1 byte) 0xNN (optional parameter to change baud rate of the Mnt App) where NN can be: 0x00 = No Baud Rate Change (similar to 4-byte command above) 0x09 = Change to 9600 Baud for Application Update speed 0x0A = Change to 19200 Baud for Application Update speed 0x0E = Change to 115200 Baud for Application Update speed All other bytes are not accepted and will result in a status of 0x01. I'm trying to test if my code works or not by creating another class (TestApplication.java) and pass the "3 differenr Baut rate" to this CPXAppliaction. the 3 Baud Rate is supposed to input by reading a file.txt. Question: How do you think these code (first half)? please don't warry about the details about the "sending part". I mean, do I need setter/getter for the "speed" parameter pass? I created the demo test class DemoApp.java (input speed by reading a txt file, and pass into CPXAppliaction). how do you think about that code? Many thanks to you guys!! public class CPXApplication extends CPXCommand { private int speed; . public CPXApplication() { speed = 9600; } public CPXApplication(int speedinit) { speed = speedinit; // TODO: where to get the speed? } protected void buildRequest() throws ElitePortException { String trans = ""; // build the full-qualified message following the protocol trans = addToRequest(trans, (char) 0); trans = addToRequest(trans, (char) 5); trans = addToRequest(trans, (char) 6); trans = addToRequest(trans, (char) 0); trans = addToRequest(trans, (char) 0); trans = addToRequest(trans, (char) 2); switch (speed) { case 9600: trans = addToRequest(trans, (char) 0x09); break; case 19200: trans = addToRequest(trans, (char) 0x0A); break; case 115200: trans = addToRequest(trans, (char) 0x0E); break; default: // TODO: unexpected baud rate. throw(); break; } trans = EncryptBinary(trans); trans = "F0." + trans; wrapRequest(trans); } protected String addToRequest(String req, char c) { return req + c; } protected String addToRequest(String req, String s) { return req + s; } protected String addToRequest(String req) { return req; } public void analyzeResponse() { //.............. } } Here is the demo test code: class Run { public static void run() { CPXAppliaction input = new CpXApplication(); int lineno = 0; try { FileReader fr = new FileReader("baudRateSpeed.txt"); BufferedReader reader = new BufferedReader(fr); String line = reader.readLine(); Scanner scan = null; while (line != null) { scan = new Scanner(line); String speed; speed = scan.next(); if (lineno == 0) { input.speed = speed; lineno++; } else { input = cpxapplication(speed, input); } line = reader.readLine(); } reader.close(); } catch (FileNotFoundException e) { System.out.println("Could not find the file"); } catch (IOException e) { System.out.println("Had a problem reading from file"); } } } public class DemoApp{ public void main(String args[]) { run(); }

    Read the article

  • How can I draw a line with a variable of width?

    - by user1729944
    #include <iostream> #include <cmath> #include "graph1.h" using namespace std; int main() { int diameter = 0; int height = 0; double rate = 0; char repeat = 'y'; int obj_num = 0; displayGraphics(); obj_num = drawRect(0,0,50,400); setColor(obj_num,200,200,200); obj_num = drawRect(0,400,640,79); setColor(obj_num,71,35,35); obj_num = drawLine(50,50,150,50,5); setColor(obj_num,80,80,80); displayBMP("faucet.bmp",150,12); do { do { cout << "Enter the diamater of the cylinder <in inches > 0 but <= 300: "; cin >> diameter; if((diameter<0) || (diameter>300)) { cout << "Incorrect diamater entered; value must be between 1 and 300" << endl; } }while((diameter<0) || (diameter>300)); do { cout << "Enter the height of the cylinder <in inches > 0 but <= 325: "; cin >> height; if((height<0) || (height>325)) { cout << "Incorrect height entered; value must be between 1 and 325" << endl; } }while((height<0) || (height>325)); do { cout << "Enter the facet water's rate: <gallons/minute> "; cin >> rate; if((rate<0) || (rate>100)) { cout << "Incorrect rate entered; value must be between 1 and 100" << endl; } }while((rate<0) || (rate>100)); //I need to draw the lines here. The graphics window has a faucet that is supposed to fill //up a cylinder made out of 3 lines. I don't know how to make the lines vary from the users //input since lines are hard coded with points and all i am receiving is the width for the //bottom line and the height for the left and right lines. cout << "Repeat program? (y/n): "; cin >> repeat; clearGraphics(); }while ( (repeat == 'y') || (repeat == 'Y') ); return 0; } Here is a screenshot for reference:

    Read the article

  • SMART Status Data Interpretation - Disk Utility

    - by Mah
    Last week my external harddisk (Seagate Barracuda 1.5TB in a custom enclosure) showed signs of failure (Disk Utility SMART Pre-failure status - several bad sectors) and I decided to change it. I bought a new HDD (Seagate Barracuda 2TB) and connected it to my Ubuntu box with a SATA to USB cable that could not report SMART status. I copied all the contents of the old HDD to the new HDD (one partition with rsync, the other with parted cp) and then gently replaced the old HDD with the new one inside my aluminum enclosure. For obscure reasons after reconnecting the new HDD through the old enclosure, the Linux box could not detect my partitions. I recovered the partitions with testdisk and restarted the computer. After the restart I checked the SMART status of the new HDD an I get this: Read Error Rate --------------- Normalized 108 Worst 99 Threshold 6 Value 16737944 I got a high value on the Seek Error Rate as well. Wondering why this happens I copied 2 GB directory from one partition to the other and rechecked the SMART status (5 minutes later). This time I got the following: Read Error Rate --------------- Normalized 109 Worst 99 Threshold 6 Value 24792504 As you see there has been an increase in the error rate. I am unable to interpret these numbers. Is my new hard disk already dying? What are the acceptable values in these fields for Seagate hard disks? Then why the assessment is still good? While I could get temperature and airflow temperature data from my old HDD, I can not fetch them for the new one. I noticed that my old hdd had got really hot sometimes. Is it possible that the enclosure is killing the harddisks due to high temperature?... Thanks

    Read the article

  • How can I improve the "smoothness" of a 2D side-scrolling iPhone game?

    - by MrDatabase
    I'm working on a relatively simple 2D side-scrolling iPhone game. The controls are tilt-based. I use OpenGL ES 1.1 for the graphics. The game state is updated at a rate of 30 Hz... And the drawing is updated at a rate of 30 fps (via NSTimer). The smoothness of the drawing is ok... But not quite as smooth as a game like iFighter. What can I do to improve the smoothness of the game? Here are the potential issues I've briefly considered: I'm varying the opacity of up to 15 "small" (20x20 pixels) textures at a time... Apparently varying the opacity in this manner can degrade drawing performance I'm rendering at only 30 fps (via NSTimer)... Perhaps 2D games like iFighter are rendered at a higher frame rate? Perhaps the game state could be updated at a faster rate? Note the acceleration vales are updated at 100 Hz... So I could potentially update part of the game state at 100 hz All of my textures are PNG24... Perhaps PNG8 would help (due to smaller size etc)

    Read the article

< Previous Page | 15 16 17 18 19 20 21 22 23 24 25 26  | Next Page >