Search Results

Search found 5783 results on 232 pages for 'translation unit'.

Page 190/232 | < Previous Page | 186 187 188 189 190 191 192 193 194 195 196 197  | Next Page >

  • PMDB Block Size Choice

    - by Brian Diehl
    Choosing a block size for the P6 PMDB database is not a difficult task. In fact, taking the default of 8k is going to be just fine. Block size is one of those things that is always hotly debated. Everyone has their personal preference and can sight plenty of good reasons for their choice. To add to the confusion, Oracle supports multiple block sizes withing the same instance. So how to decide and what is the justification? Like most OLTP systems, Oracle Primavera P6 has a wide variety of data. A typical table's average row size may be less than 50 bytes or upwards of 500 bytes. There are also several tables with BLOB types but the LOB data tends not to be very large. It is likely that no single block size would be perfect for every table. So how to choose? My preference is for the 8k (8192 bytes) block size. It is a good compromise that is not too small for the wider rows, yet not to big for the thin rows. It is also important to remember that database blocks are the smallest unit of change and caching. I prefer to have more, individual "working units" in my database. For an instance with 4gb of buffer cache, an 8k block will provide 524,288 blocks of cache. The following SQL*Plus script returns the average, median, min, and max rows per block. column "AVG(CNT)" format 999.99 set verify off select avg(cnt), median(cnt), min(cnt), max(cnt), count(*) from ( select dbms_rowid.ROWID_RELATIVE_FNO(rowid) , dbms_rowid.ROWID_BLOCK_NUMBER(rowid) , count(*) cnt from &tab group by dbms_rowid.ROWID_RELATIVE_FNO(rowid) , dbms_rowid.ROWID_BLOCK_NUMBER(rowid) ) Running this for the TASK table, I get this result on a database with an 8k block size. Each activity, on average, has about 19 rows per block. Enter value for tab: task AVG(CNT) MEDIAN(CNT) MIN(CNT) MAX(CNT) COUNT(*) -------- ----------- ---------- ---------- ---------- 18.72 19 3 28 415917 I recommend an 8k block size for the P6 transactional database. All of our internal performance and scalability test are done with this block size. This does not mean that other block sizes will not work. Instead, like many other parameters, this is the safest choice.

    Read the article

  • Strangling the life out of Software Testing

    - by MarkPearl
    I recently did a course at the local university on Software Engineering. At the beginning of the course I looked over the outline of the subject and there seemed to be some really good content. It covered traditional & agile project methodologies, some general communication and modelling chapters and finished off with testing. I was particularly excited to see the section on testing as this was something I learnt on my own and see great value in. The course has now just ended and I am very disappointed. I now know one of the reasons why so few people i.e. in my region do Test Driven Development, or perform even basic testing methodologies. The topic was to academic! Yes, you might be able to list 4 different types of black box test approaches vs. white box test approaches and describe the characteristics of Smoke Tests, but never during course did we see an example of an actual test or how it might be implemented! In fact, if I did not have personal experience of applying testing in actual projects, I wouldn’t even know what a unit test looked like. Now, what worries me is the following… It took us 6 months to cover the course material, other students more than likely came out of that course with little appreciation of the subject – in fact they now have a very complex view of what a test is – so complex that I think most of them will never attempt it again on their own. Secondly, imagine studying to be a dentist without ever actually seeing a tooth? Yes, you might be able to describe a tooth, and know what it is made out of – but nobody would want a dentist who has never seen a tooth to operate on them. Yet somehow we expect people studying software engineering to do the same? This is not right. Now, before I finish my rant let me say that I know this is not the same everywhere in the world, and that there needs to be a balance on practical implementation and academic understanding – I am just disappointed that this does not seem to be happening at the institution that I am currently studying at ;-( Please, if you happen to be a lecturer or teacher reading this post – a combination of theory and practical's goes a long way. We need to up the quality of software being produced and that starts at learner level!

    Read the article

  • Port forwarding on Fortigate 50B

    - by sindre j
    I have serious problems setting up port forwarding on a Fortigate 50B. The unit is basically running as factory default, the wan1 interface is connected to my fibre optic internet modem, and my lan is connected to the internal switch of the Fortigate. The factory default firewall policy allowing traffic from the internal interface to wan1 is kept and I'm able to access the interet as normal. Then I added a virtual ip and a firewall policy for allowing access from the internet to my local servers (ip 192.168.9.51) webserver (standard port 80). The settings I made are as follows. Edit Virtual IP Mapping Name : Server VIP External interface : wan1 Type : Static NAT Extermal IP Address/Range : 0.0.0.0 Mapped IP Address/Range : 192.168.9.51 Port Forwading : not checked Firewall policy Source interface/Zone : wan1 Source address : all Destination interface/Zone : internal Destination address : Server VIP Schedule : always Service : HTTP Action : ACCEPT no other settings checked What happens now is that I'm unable to access internet from my server, I'm not getting through to the webserver from internet either. I'm able to ping a site on the outside, but all web traffic is blocked, both ways. I've checked the documentation, but as far as I can tell I have set this up correctly. Anyone here with knowledge of Fortigate port forwading/NAT?

    Read the article

  • Smart Array P400 - Accelerator Replacement Battery Failure

    - by inflammable
    TL;DR - Is the immediate failure of a replacement battery, for a failed battery, on a battery backed accelerator for a Smart Array P400 controller a common occurrence? Or are we likely to have an storage controller with an impending and critical fault? We have a slightly confusing situation with a Smart Array P400 storage controller with the 512mb battery backed accelerator addon on an HP DL380 server. The storage controller is (afaik) running the latest firmware and driver: Model: Smart Array P400 Controller Status: OK Firmware Version: 7.24 Serial Number: *snip* Rebuild Priority: Medium Expand Priority: Medium Number Of Ports: 2 The storage diagnostic (both on the both boot-up screen for the controller and within the 'Management Homepage' and the 'HP Array Diagnostic Utility') recently starting showing the following status a fault for the battery for the accelerator: Accelerator Status: Temporarily Disabled Error Code: Cache Disabled Low Batteries Serial Number: *snip* Total Memory: 524288 KB Read Cache: 25% Write Cache: 75% Battery Status: Failed Read Errors: 0 Write Errors: 0 We replaced the battery with a new unit (a visual inspection of the P400 card showing nothing unusual) and saw the same fault - but expected this to disappear over the course of a few hours/days as it charged. This didn't happy, and the fault status remains the same as above. Given the battery is a genuine part from HP, I wouldn't have expected a replacement battery to fail straight away, or to be dead-on-arrival (is that naivety on my part?). Is the immediate failure of a replacement battery, for a failed battery, on a battery backed accelerator a common occurrence? Or are we likely to have an storage controller with an impending and critical fault? Is there any diagnostic that could tell me more about the failed battery, without cracking the server open again? Many thanks!

    Read the article

  • Cisco AnyConnect on IOS 12.4(20)T

    - by natacado
    There are plenty of tutorials on setting up AnyConnect on an ASA unit, and a handful of links noting that IOS 12.4(15) and later support AnyConnect, but I can't seem to find any good documentation about how to setup AnyConnect on IOS; most tutorials assume you only want a clientless VPN on IOS. the best I've found is this document on Cisco's site, but it's not working for me in practice - see below. This is all on a Cisco 881W: router#show version | include Version Cisco IOS Software, C880 Software (C880DATA-UNIVERSALK9-M), Version 12.4(20)T1, RELEASE SOFTWARE (fc3) ROM: System Bootstrap, Version 12.4(15r)XZ2, RELEASE SOFTWARE (fc1) The old SSL VPN Client seems to install just fine: router#show webvpn install status svc SSLVPN Package SSL-VPN-Client version installed: CISCO STC win2k+ 1.0.0 1,1,4,176 Thu 08/16/2007 12:37:00.43 However, when I install the AnyConnect client, after authenticating it hangs for a while during the self-update process, and stops with an error that the "AnyConnect package unavailable or corrupted." When I try to install the AnyConnect package on the router, I'm told that it's an invalid archive: router(config)#webvpn install svc flash:/webvpn/anyconnect-win-2.3.2016-k9.pkg SSLVPN Package SSL-VPN-Client (seq:2): installed Error: Invalid Archive Does anyone have a good sample on how to get the 2.x AnyConnect clients working with a Cisco device running IOS?

    Read the article

  • Linux e1000e (Intel networking driver) problems galore, where do I start?

    - by Evan Carroll
    I'm currently having a major problem with e1000e (not working at all) in Ubuntu Maverick (1.0.2-k4), after resume I'm getting a lot of stuff in dmesg: [ 9085.820197] e1000e 0000:02:00.0: PCI INT A disabled [ 9089.907756] e1000e: Intel(R) PRO/1000 Network Driver - 1.0.2-k4 [ 9089.907762] e1000e: Copyright (c) 1999 - 2009 Intel Corporation. [ 9089.907797] e1000e 0000:02:00.0: Disabling ASPM L1 [ 9089.907827] e1000e 0000:02:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 9089.907857] e1000e 0000:02:00.0: setting latency timer to 64 [ 9089.908529] e1000e 0000:02:00.0: irq 44 for MSI/MSI-X [ 9089.908922] e1000e 0000:02:00.0: Disabling ASPM L0s [ 9089.908954] e1000e 0000:02:00.0: (unregistered net_device): PHY reset is blocked due to SOL/IDER session. [ 9090.024625] e1000e 0000:02:00.0: eth0: (PCI Express:2.5GB/s:Width x1) 00:0a:e4:3e:ce:74 [ 9090.024630] e1000e 0000:02:00.0: eth0: Intel(R) PRO/1000 Network Connection [ 9090.024712] e1000e 0000:02:00.0: eth0: MAC: 2, PHY: 2, PBA No: 005302-003 [ 9090.109492] e1000e 0000:02:00.0: irq 44 for MSI/MSI-X [ 9090.164219] e1000e 0000:02:00.0: irq 44 for MSI/MSI-X and, a bunch of [ 2128.005447] e1000e 0000:02:00.0: eth0: Detected Hardware Unit Hang: [ 2128.005452] TDH <89> [ 2128.005454] TDT <27> [ 2128.005456] next_to_use <27> [ 2128.005458] next_to_clean <88> [ 2128.005460] buffer_info[next_to_clean]: [ 2128.005463] time_stamp <6e608> [ 2128.005465] next_to_watch <8a> [ 2128.005467] jiffies <6f929> [ 2128.005469] next_to_watch.status <0> [ 2128.005471] MAC Status <80080703> [ 2128.005473] PHY Status <796d> [ 2128.005475] PHY 1000BASE-T Status <4000> [ 2128.005477] PHY Extended Status <3000> [ 2128.005480] PCI Status <10> I decided to compile the latest stable e1000e to 1.2.17, now I'm getting: [ 9895.678050] e1000e: Intel(R) PRO/1000 Network Driver - 1.2.17-NAPI [ 9895.678055] e1000e: Copyright(c) 1999 - 2010 Intel Corporation. [ 9895.678098] e1000e 0000:02:00.0: Disabling ASPM L1 [ 9895.678129] e1000e 0000:02:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 9895.678162] e1000e 0000:02:00.0: setting latency timer to 64 [ 9895.679136] e1000e 0000:02:00.0: irq 44 for MSI/MSI-X [ 9895.679160] e1000e 0000:02:00.0: Disabling ASPM L0s [ 9895.679192] e1000e 0000:02:00.0: (unregistered net_device): PHY reset is blocked due to SOL/IDER session. [ 9895.791758] e1000e 0000:02:00.0: eth0: (PCI Express:2.5GB/s:Width x1) 00:0a:e4:3e:ce:74 [ 9895.791766] e1000e 0000:02:00.0: eth0: Intel(R) PRO/1000 Network Connection [ 9895.791850] e1000e 0000:02:00.0: eth0: MAC: 3, PHY: 2, PBA No: 005302-003 [ 9895.892464] e1000e 0000:02:00.0: irq 44 for MSI/MSI-X [ 9895.948175] e1000e 0000:02:00.0: irq 44 for MSI/MSI-X [ 9895.949111] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 9895.954694] e1000e: eth0 NIC Link is Up 10 Mbps Full Duplex, Flow Control: RX/TX [ 9895.954703] e1000e 0000:02:00.0: eth0: 10/100 speed: disabling TSO [ 9895.955157] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 9906.832056] eth0: no IPv6 routers present With 1.2.20 I get: [ 9711.525465] e1000e: Intel(R) PRO/1000 Network Driver - 1.2.20-NAPI [ 9711.525472] e1000e: Copyright(c) 1999 - 2010 Intel Corporation. [ 9711.525521] e1000e 0000:02:00.0: Disabling ASPM L1 [ 9711.525554] e1000e 0000:02:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 9711.525586] e1000e 0000:02:00.0: setting latency timer to 64 [ 9711.526460] e1000e 0000:02:00.0: irq 45 for MSI/MSI-X [ 9711.526487] e1000e 0000:02:00.0: Disabling ASPM L0s [ 9711.526523] e1000e 0000:02:00.0: (unregistered net_device): PHY reset is blocked due to SOL/IDER session. [ 9711.639763] e1000e 0000:02:00.0: eth0: (PCI Express:2.5GB/s:Width x1) 00:0a:e4:3e:ce:74 [ 9711.639771] e1000e 0000:02:00.0: eth0: Intel(R) PRO/1000 Network Connection [ 9711.639854] e1000e 0000:02:00.0: eth0: MAC: 3, PHY: 2, PBA No: 005302-003 [ 9712.060770] e1000e 0000:02:00.0: irq 45 for MSI/MSI-X [ 9712.116195] e1000e 0000:02:00.0: irq 45 for MSI/MSI-X [ 9712.117098] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 9712.122684] e1000e: eth0 NIC Link is Up 100 Mbps Full Duplex, Flow Control: RX/TX [ 9712.122693] e1000e 0000:02:00.0: eth0: 10/100 speed: disabling TSO [ 9712.123142] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 9722.920014] eth0: no IPv6 routers present But, I'm still getting these [ 9982.992851] PCI Status <10> [ 9984.993602] e1000e 0000:02:00.0: eth0: Detected Hardware Unit Hang: [ 9984.993606] TDH <5d> [ 9984.993608] TDT <6b> [ 9984.993611] next_to_use <6b> [ 9984.993613] next_to_clean <5b> [ 9984.993615] buffer_info[next_to_clean]: [ 9984.993617] time_stamp <24da80> [ 9984.993619] next_to_watch <5d> [ 9984.993621] jiffies <24f200> [ 9984.993624] next_to_watch.status <0> [ 9984.993626] MAC Status <80080703> [ 9984.993628] PHY Status <796d> [ 9984.993630] PHY 1000BASE-T Status <4000> [ 9984.993632] PHY Extended Status <3000> [ 9984.993635] PCI Status <10> [ 9986.001047] e1000e 0000:02:00.0: eth0: Reset adapter [ 9986.176202] e1000e: eth0 NIC Link is Up 10 Mbps Full Duplex, Flow Control: RX/TX [ 9986.176211] e1000e 0000:02:00.0: eth0: 10/100 speed: disabling TSO I'm not sure where to start troubleshooting this. Any ideas? Here is the result of ethtool -d eth0 MAC Registers ------------- 0x00000: CTRL (Device control register) 0x18100248 Endian mode (buffers): little Link reset: reset Set link up: 1 Invert Loss-Of-Signal: no Receive flow control: enabled Transmit flow control: enabled VLAN mode: disabled Auto speed detect: disabled Speed select: 1000Mb/s Force speed: no Force duplex: no 0x00008: STATUS (Device status register) 0x80080703 Duplex: full Link up: link config TBI mode: disabled Link speed: 10Mb/s Bus type: PCI Express Port number: 0 0x00100: RCTL (Receive control register) 0x04048002 Receiver: enabled Store bad packets: disabled Unicast promiscuous: disabled Multicast promiscuous: disabled Long packet: disabled Descriptor minimum threshold size: 1/2 Broadcast accept mode: accept VLAN filter: enabled Canonical form indicator: disabled Discard pause frames: filtered Pass MAC control frames: don't pass Receive buffer size: 2048 0x02808: RDLEN (Receive desc length) 0x00001000 0x02810: RDH (Receive desc head) 0x00000001 0x02818: RDT (Receive desc tail) 0x000000F0 0x02820: RDTR (Receive delay timer) 0x00000000 0x00400: TCTL (Transmit ctrl register) 0x3103F0FA Transmitter: enabled Pad short packets: enabled Software XOFF Transmission: disabled Re-transmit on late collision: enabled 0x03808: TDLEN (Transmit desc length) 0x00001000 0x03810: TDH (Transmit desc head) 0x00000000 0x03818: TDT (Transmit desc tail) 0x00000000 0x03820: TIDV (Transmit delay timer) 0x00000008 PHY type: IGP2 and ethtool -c eth0 Coalesce parameters for eth0: Adaptive RX: off TX: off stats-block-usecs: 0 sample-interval: 0 pkt-rate-low: 0 pkt-rate-high: 0 rx-usecs: 3 rx-frames: 0 rx-usecs-irq: 0 rx-frames-irq: 0 tx-usecs: 0 tx-frames: 0 tx-usecs-irq: 0 tx-frames-irq: 0 rx-usecs-low: 0 rx-frame-low: 0 tx-usecs-low: 0 tx-frame-low: 0 rx-usecs-high: 0 rx-frame-high: 0 tx-usecs-high: 0 tx-frame-high: 0 Here is also the lspci -vvv for this controller 02:00.0 Ethernet controller: Intel Corporation 82573L Gigabit Ethernet Controller Subsystem: Lenovo ThinkPad X60s Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR+ FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0, Cache Line Size: 64 bytes Interrupt: pin A routed to IRQ 45 Region 0: Memory at ee000000 (32-bit, non-prefetchable) [size=128K] Region 2: I/O ports at 2000 [size=32] Capabilities: [c8] Power Management version 2 Flags: PMEClk- DSI+ D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+) Status: D0 NoSoftRst- PME-Enable- DSel=0 DScale=1 PME- Capabilities: [d0] MSI: Enable+ Count=1/1 Maskable- 64bit+ Address: 00000000fee0300c Data: 415a Capabilities: [e0] Express (v1) Endpoint, MSI 00 DevCap: MaxPayload 256 bytes, PhantFunc 0, Latency L0s <512ns, L1 <64us ExtTag- AttnBtn- AttnInd- PwrInd- RBE- FLReset- DevCtl: Report errors: Correctable+ Non-Fatal+ Fatal+ Unsupported+ RlxdOrd+ ExtTag- PhantFunc- AuxPwr- NoSnoop+ MaxPayload 128 bytes, MaxReadReq 512 bytes DevSta: CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr+ TransPend- LnkCap: Port #0, Speed 2.5GT/s, Width x1, ASPM L0s L1, Latency L0 <128ns, L1 <64us ClockPM+ Surprise- LLActRep- BwNot- LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk+ ExtSynch- ClockPM+ AutWidDis- BWInt- AutBWInt- LnkSta: Speed 2.5GT/s, Width x1, TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt- Capabilities: [100 v1] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq+ ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP+ SDES- TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr- CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr- AERCap: First Error Pointer: 14, GenCap- CGenEn- ChkCap- ChkEn- Capabilities: [140 v1] Device Serial Number 00-0a-e4-ff-ff-3e-ce-74 Kernel driver in use: e1000e Kernel modules: e1000e I filed a bug on this upstream, still no idea how to get more useful information. Here is a the result of the running that script EEPROM FIX UPDATE $ sudo bash fixeep-82573-dspd.sh eth0 eth0: is a "82573L Gigabit Ethernet Controller" This fixup is applicable to your hardware Your eeprom is up to date, no changes were made Do I still need to do anything? Also here is my EEPROM dump $ sudo ethtool -e eth0 Offset Values ------ ------ 0x0000 00 0a e4 3e ce 74 30 0b b2 ff 51 00 ff ff ff ff 0x0010 53 00 03 02 6b 02 7e 20 aa 17 9a 10 86 80 df 80 0x0020 00 00 00 20 54 7e 00 00 14 00 da 00 04 00 00 27 0x0030 c9 6c 50 31 3e 07 0b 04 8b 29 00 00 00 f0 02 0f 0x0040 08 10 00 00 04 0f ff 7f 01 4d ff ff ff ff ff ff 0x0050 14 00 1d 00 14 00 1d 00 af aa 1e 00 00 00 1d 00 0x0060 00 01 00 40 1f 12 07 40 ff ff ff ff ff ff ff ff 0x0070 ff ff ff ff ff ff ff ff ff ff ff ff ff ff 4a e0 I'd also like to note that I used eth0 every day for years and until recently never had an issue.

    Read the article

  • Problem with switch dell 6224

    - by Matias
    Hello, we just have upgraded the firmware of a dell 6224 power connect switch and it won't reload. These are the symptons: - I power up the switch having the serial cable connected to it and the switch outputs nothing. The configuration of the serial console is fine: 9600 bds, etc... In fact, before the upgrade, I was connected to the switch through the very same cable. - Reseting the switch with its reset pinhole does not reset the switch: the power and fan lights powers off while I keep pressed the pinhole, but the switch itself does not resets. - When I connect an UTP cable to one of the switches port, the green lights don't flash, but ''mii-tool eth0'' in my laptop shows there is link!! The only thing I see in the output, different from other upgrades I've done, is this line at the end: Erasing Boot Flash.....^^^^Done. Any help or idea will be more than welcome!! Thanks!! console#show version Image Descriptions image1 : image2 : Images currently available on Flash -------------------------------------------------------------------- unit image1 image2 current-active next-active 1 <none> 3.0.0.8 image2 image2 console#boot system image2 Activating image image2 .. console#update bootcode Update bootcode and reset (Y/N)? Updating boot code ... Extracting boot code from image... Erasing Boot Flash.....^^^^Done.

    Read the article

  • Postfix won't run while selinux in enforcing mode

    - by Dina Abu-khader
    I enabled selinux forcing mode on Fedora 15 , and I was able to get apache, mysql and memcached to work fine , but I couldn't get postfix to run . I got the following errors : systemd[1]: Unit postfix.service entered failed state. kernel: [146194.117602] type=1400 audit(1318924444.361:3809): avc: denied { module_request } for pid=15447 comm="postfix" kmod="net-pf-10" scontext=system_u:system_r:postfix_master_t:s0 tcontext=system_u:system_r:kernel_t:s0 tclass=system kernel: [146194.145456] type=1400 audit(1318924444.389:3810): avc: denied { module_request } for pid=15452 comm="master" kmod="net-pf-10" scontext=system_u:system_r:postfix_master_t:s0 tcontext=system_u:system_r:kernel_t:s0 tclass=system kernel: [146194.146585] type=1400 audit(1318924444.390:3811): avc: denied { module_request } for pid=15452 comm="master" kmod="net-pf-10" scontext=system_u:system_r:postfix_master_t:s0 tcontext=system_u:system_r:kernel_t:s0 tclass=system kernel: [146194.390715] type=1400 audit(1318924444.633:3812): avc: denied { module_request } for pid=15479 comm="postsuper" kmod="net-pf-10" scontext=system_u:system_r:postfix_master_t:s0 tcontext=system_u:system_r:kernel_t:s0 tclass=system kernel: [146194.451670] type=1400 audit(1318924444.694:3813): avc: denied { module_request } for pid=15516 comm="postlog" kmod="net-pf-10" scontext=system_u:system_r:postfix_master_t:s0 tcontext=system_u:system_r:kernel_t:s0 tclass=system kernel: [146194.459587] type=1400 audit(1318924444.702:3814): avc: denied { module_request } for pid=15517 comm="master" kmod="net-pf-10" scontext=system_u:system_r:postfix_master_t:s0 tcontext=system_u:system_r:kernel_t:s0 tclass=system kernel: [146194.460786] type=1400 audit(1318924444.703:3815): avc: denied { module_request } for pid=15517 comm="master" kmod="net-pf-10" scontext=system_u:system_r:postfix_master_t:s0 tcontext=system_u:system_r:kernel_t:s0 tclass=system systemd[1]: PID 15517 read from file /var/spool/postfix/pid/master.pid does not exist. Your service or init script might be broken. systemd[1]: postfix.service: main process exited, code=exited, status=1 following steps were done : I reinstall postfix Created .autorelable and reboot restorecon -R -v /etc/postfix restorecon -R -v /var/lib/postfix Can someone tell me what am doing wrong ? Update It turns out that we have to disable the ipv6 in the main.cf and these errors were disappear. THank you

    Read the article

  • Excel VBA: select every other cell in a row range to be copied and pasted vertically

    - by terry alexander
    i have a 2200+ page text file. It is delivered from a customer through a data exchange to us with astericks to separate values and tildes (~) to denote the end of a row. The file is sent to me as a text file in Word. Most rows are split in two (1 row covers a full line and part of a second line). i transfer segments (10 page chunks) of it at a time into Excel where, unfortunately, any zeroes that occur at the end of a row get discarded in the "text to columns" procedure. So, i eyeball every "long" row to insure that zeroes were not lost and manually re-enter any that were. Here is a small bit of sample data: SDQ EA 92 1551 378 1601 151 1603 157 1604 83 The "SDQ, EA, and 92" are irrelevant (artifacts of data transmission). i want to use Excel VBA to select 1551, 1601, 1603, and 1604 (these are store numbers) so that i can copy those values and transpose paste them vertically. i will then go back and copy 378, 151, 157, and 83 (sales values) so that i can transpose paste them next to the store numbers. The next two rows of data contain the same store numbers but give the corresponding dollar values. i will only need to copy the dollar values so they can be transpose pasted vertically next to unit values (e.g. 378, 151, 157, and 83). Just being able to put my cursor on the first cell of interest in the row and run a macro to copy every other cell would speed up my work tremendously. i have tried using activecell and offset references to select a range to copy but have not been successful. Does any have any suggestions for me? Thanks in advance for the help.

    Read the article

  • Htpc aka "Media Center": cheap and *silent*?

    - by Unknown
    It may be me, or the place I live (Italy), but it seems pretty hard to get a build or a prebuilt nettop or a laptop that fits the need. I need something silent able to playback all h.264 fullhd content without stuttering, and well (and not loosing the hw acceleration because of softsubs...) silent not ugly silent and (possibly) cheap. I'm going the linux route, therefore i'm moving towards a cpu-based or nvida-integrated solution (i don't think ati hw accelerated playback - or the intel "hd" acceleration - is useable yet). Ion nettop; it's either the Acer Revo (but here it's incredibly pricey and it's hard to find the dualcore version) or the Asrock Ion 330, that in the current version is rated "silent" at 26Db. 26. Sounds pretty noisy to me!!! the previous version was even worse. was this product really aimed at htpc market?? the Dell Zino - i think it's ATI based unfortunately. Laptop: correct me if I'm wrong: sub 600€/$ units are quite loud under full load (because of the tiny fans). ULW laptops are indeed quite similar: tiniest fans = high pitched noise and the cpu still lacks power for non hd-accelerated video decoding Handmade build: little money can be saved with underpowered cpus, a low-midrange cpu would help in the case of non-hw-accelerated content the cases are quite pricey the PSU one has to get ranges between 100/150 €/$ minimum to keep the noise down a low-mid build, all included, sums up to over 650 €/$ for a still-looking-ugly-unit, without the blu-ray drive. Please help. What do you advise on this? ;) Am I ignoring laptops too much, maybe? Are low-priced Acers that noisy/high pitched under full load?

    Read the article

  • ZFS - Impact of L2ARC cache device failure (Nexenta)

    - by ewwhite
    I have an HP ProLiant DL380 G7 server running as a NexentaStor storage unit. The server has 36GB RAM, 2 LSI 9211-8i SAS controllers (no SAS expanders), 2 SAS system drives, 12 SAS data drives, a hot-spare disk, an Intel X25-M L2ARC cache and a DDRdrive PCI ZIL accelerator. This system serves NFS to multiple VMWare hosts. I also have about 90-100GB of deduplicated data on the array. I've had two incidents where performance tanked suddenly, leaving the VM guests and Nexenta SSH/Web consoles inaccessible and requiring a full reboot of the array to restore functionality. In both cases, it was the Intel X-25M L2ARC SSD that failed or was "offlined". NexentaStor failed to alert me on the cache failure, however the general ZFS FMA alert was visible on the (unresponsive) console screen. The zpool status output showed: pool: vol1 state: ONLINE scan: scrub repaired 0 in 0h57m with 0 errors on Sat May 21 05:57:27 2011 config: NAME STATE READ WRITE CKSUM vol1 ONLINE 0 0 0 mirror-0 ONLINE 0 0 0 c8t5000C50031B94409d0 ONLINE 0 0 0 c9t5000C50031BBFE25d0 ONLINE 0 0 0 mirror-1 ONLINE 0 0 0 c10t5000C50031D158FDd0 ONLINE 0 0 0 c11t5000C5002C823045d0 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 c12t5000C50031D91AD1d0 ONLINE 0 0 0 c2t5000C50031D911B9d0 ONLINE 0 0 0 mirror-3 ONLINE 0 0 0 c13t5000C50031BC293Dd0 ONLINE 0 0 0 c14t5000C50031BD208Dd0 ONLINE 0 0 0 mirror-4 ONLINE 0 0 0 c15t5000C50031BBF6F5d0 ONLINE 0 0 0 c16t5000C50031D8CFADd0 ONLINE 0 0 0 mirror-5 ONLINE 0 0 0 c17t5000C50031BC0E01d0 ONLINE 0 0 0 c18t5000C5002C7CCE41d0 ONLINE 0 0 0 logs c19t0d0 ONLINE 0 0 0 cache c6t5001517959467B45d0 FAULTED 2 542 0 too many errors spares c7t5000C50031CB43D9d0 AVAIL errors: No known data errors This did not trigger any alerts from within Nexenta. I was under the impression that an L2ARC failure would not impact the system. But in this case, it surely was the culprit. I've never seen any recommendations to RAID L2ARC. Removing the bad SSD entirely from the server got me back running, but I'm concerned about the impact of the device failure (and maybe the lack of notification from NexentaStor as well). Edit - What's the current best-choice SSD for L2ARC cache applications these days?

    Read the article

  • Time drift in Cloud Server - need to mainpulate GRUB config

    - by Aditya Advani
    We are hosting a VPS on a popular host and are experiencing a regular time drift of several minutes a day forward (approx 7). Linux Kernel: 2.6.18-164.11.1.el5 GNU/Linux Distro: CentOS release 5.4 (Final) We reached out to our hosting provider and their support advised us " This is a known issue with Cloud Servers. To fix this you will need to add one line to your grub config located at: /boot/grub/menu.lst The line you need to add is: noapic nolapic divider=10 nolapic_timer This should correct this issue. You will need to restart after this is added in. " Because I am wary of manipulating grub, mostly I'm terrified that our server may fail to restart - I ask you guys, the pro *nix admins - where exactly in this file does the recommended insertion below: # line from 1&1 for time syncing issue (Case 5163) noapic nolapic divider=10 nolapic_timer go? Please specify where exactly, and whether the order of commands is or is not important. Why is the block below "title CentOS ..." indented? If someone could give me an overview of how this works or point me to a resource that's easy to follow, that's what I'm looking for immediately, a light overview or basic understanding of what I;m doing. If GRUB and bootloaders are a deep dark treasure trove of kernel hacking or something, that's great well-recommended in-depth resources are also very welcome. This is my current /boot/grub/menu.lst # grub.conf generated by anaconda # # Note that you do not have to rerun grub after making changes to this file #boot=/dev/sda # serial --unit=0 --speed=57600 terminal --timeout=5 serial console timeout=5 title CentOS (2.6.18-164.11.1.el5) root (hd0,0) kernel /boot/vmlinuz-2.6.18-164.11.1.el5 ro root=/dev/hda1 console=tty0 console=tty initrd /boot/initrd-2.6.18-164.11.1.el5.img MOST IMPORTANT: I need to know where in the file above it is appropriate to paste the suggested line so I can confidently restart my VPS after manipulating GRUB config

    Read the article

  • Dual Xeon Server voltages are low

    - by Mindflux
    I've got a whitebox server running CentOS 5.7. It's a Dual Xeon 5620, 24GB of RAM. The mainboard is a SuperMicro X8DT6-F and the chassis is a SC825TQ-R720LPB. Dual 720W Power supplies. We had a big power outage a couple weeks back that took down everything, I don't have any pre-power outage figures for this server, and the only reason I noticed these is because when I was bringing up the servers I was checking them out with more scrutiny than usual. http://i.imgur.com/rSjiw.png (Image of voltage readings) As you can see, CPU1 DIMM is low, +3.3V is high, 3.3VSB is high, +5v is high, +12v is REAL LOW (out of normal 5% (plus/minus))... and VBAT is off the charts. With my whitebox VAR we've tried the following: Swap out PSU with another server I have with the same PSUs. Try different power cord Update BMC/IPMI firmware in case readings were wrong (They aren't) Update BIOS Try different PDU Try a different outlet and/or circuit Replaced Voltage Regulator Unit At this point, the only thing we haven't done, seemingly is replace the mainboard.. which is what the next step will be unless something else shines some light on the situation. I should mention the system is rock solid otherwise which is a surprise given the 12v voltage is that far off.

    Read the article

  • How to eliminate overscan on Ubuntu HTPC

    - by Norman Ramsey
    I'm using an Ubuntu box with Nvidia graphics card as an HTPC. My HDTV is a Sony Bravia KDS-R50XBR1; this is a rear-projection unit with many inputs. I am using the HDMI input. I'm using the proprietary Nvidia drivers and they recognize the 1080x1920 resolution just fine. The display is a little fuzzy but at 50 inches it's perfect for movies. My problem is that the TV has three overscan settings, and none of them reduces overscan to zero. When I was using dual-screen this was fine, but I'm moving to where the TV is my only screen, and the Gnome panels are not visible because of the overscan. I'd like to figure out how to eliminate the overscan, without trying to scale my 1080p content down to 920p or something ridiculous like that. Ideally there would be some scurvy trick, perhaps involving the TV service menu, to get rid of the overscan on the TV side. Or I could move the Gnome panels, but I still would be missing the edges of my movies. Suggestions most welcome.

    Read the article

  • Symantec Endpoint Protection Virus Definitions

    - by Gus Denton
    I have done some Googling but I cannot get a definitive answer certainly not from the Symantec KB. I have a Virtualised Win 2003R2 server 32bit. It has been provisioned to me with Symantec Endpoint Protection 11.0.62xxx CLIENT (not a definitions server) the directory C:\Program Files\Common Files\Symantec Shared\VirusDefs is 750MB IT doesn't contain .tmp directories so it is NOT a corrupt definitions server. IT does contain directories named with a date pattern YYYYMMDD.xxx Some of these folders are 12 months old and I would like to recover the space. The sysmantect forums are full of this stuff but a lot of the postings contain links back to documents that are not specific to End Point Protection Client. It appears that I should be able to delete the older folders and all will be OK. with a service restart however there is a warning about having Live Update Administrator Installed Firstly I have no idea if I have this installed how to I check and secondly can I just ditch these old files and restart ? Regards Gus Denton Learning and Teaching Uni of New South Wales Sydney Australia For those trying to assist me I thankyou. I have followed some instructions found on the Symantec site and assumed that the response from Nixphoe would resolve my issue. It appears that as I am on a provisioned VM from a central IT unit I cannot run the Symantec commands from the Run prompt as my admin creds to get me in. (smc -stop) Basically I need to claw back some Diskspace from the c: drive which is being filed up with WSUS patches and Symantec files. I have managed to delete one symantec cache through the live update control panel and recovered 470Mb I suppose my last question for those more experienced than myself is, can I simply remove say the two oldest virus definition folders without completely foobaring the End Point protection and the server ? Regards Gus

    Read the article

  • package issue with ubuntu 10.10 and passenger requirements

    - by user368937
    I'm trying to get Passenger working with Ubuntu 10.10 and I'm running into a problem. It seems that the passenger installer is not recognizing the virtual package. I'm getting this error: Code: passenger-install-apache2-module ... * OpenSSL support for Ruby... not found ... And then it says, run this: * To install OpenSSL support for Ruby: Please run apt-get install libopenssl-ruby as root. When I run the above command, it refers to the libruby package: sudo apt-get install libopenssl-ruby Reading package lists... Done Building dependency tree Reading state information... Done Note, selecting 'libruby' instead of 'libopenssl-ruby' libruby is already the newest version. 0 upgraded, 0 newly installed, 0 to remove and 43 not upgraded. When I look at the details for libruby, it says it provides libopenssl-ruby: Code: Provides: libbigdecimal-ruby, libcurses-ruby, libdbm-ruby, libdl-ruby, libdrb-ruby, liberb-ruby, libgdbm-ruby, libiconv-ruby, libopenssl-ruby, libpty-ruby, libracc-runtime-ruby, libreadline-ruby, librexml-ruby, libsdbm-ruby, libstrscan-ruby, libsyslog-ruby, libtest-unit-ruby, libwebrick-ruby, libxmlrpc-ruby, libyaml-ruby, libzlib-ruby And when I rerun the passenger installer, it gives the same error: Code: passenger-install-apache2-module ... * OpenSSL support for Ruby... not found ... Let me know if you need more info. How do I fix this?

    Read the article

  • Failed to mount to nfs server with "Program not Registered"

    - by Farrel
    I'm trying to setup nfs server on Fedora 17 and I'm getting "Program not Registered" error when I'm trying to mount. I guess the main reason for this is rpcbind. I'm a newbie in linux, so I don't know what info should I provide you with. Here is some info that might be useful. rpcinfo -p program vers proto port service 100000 4 tcp 111 portmapper 100000 3 tcp 111 portmapper 100000 2 tcp 111 portmapper 100000 4 udp 111 portmapper 100000 3 udp 111 portmapper 100000 2 udp 111 portmapper 100005 1 udp 20048 mountd 100005 1 tcp 20048 mountd 100005 2 udp 20048 mountd 100005 2 tcp 20048 mountd 100005 3 udp 20048 mountd 100005 3 tcp 20048 mountd 100024 1 udp 42223 status 100024 1 tcp 50054 status cat /etc/exports /home/Farrel/prog 192.168.xxx.xxx (ro,sync) service nfs status Redirecting to /bin/systemctl status nfs.service nfs-server.service - NFS Server Loaded: loaded (/usr/lib/systemd/system/nfs-server.service; enabled) Active: active (exited) since Fri, 02 Nov 2012 09:29:04 +0300; 5min ago Process: 924 ExecStartPost=/usr/lib/nfs-utils/scripts/nfs-server.postconfig (code=exited, status=0/SUCCESS) Process: 909 ExecStart=/usr/sbin/rpc.nfsd $RPCNFSDARGS ${RPCNFSDCOUNT} (code=exited, status=0/SUCCESS) Process: 885 ExecStartPre=/usr/sbin/exportfs -r (code=exited, status=0/SUCCESS) Process: 864 ExecStartPre=/usr/lib/nfs-utils/scripts/nfs-server.preconfig (code=exited, status=0/SUCCESS) CGroup: name=systemd:/system/nfs-server.service Warning: Journal has been rotated since unit was started. Log output is incomplete or unavailable. Firewall is disabled on both systems. I spent a lot of time reading on the topic but all manuals on setting up nfs server lead to "Program not Registered" error. Any how-to-fix-it ideas?

    Read the article

  • Does a 3ware "ECC-ERROR" matter on a JBOD when I have ZFS?

    - by Stefan Lasiewski
    I have a FreeBSD 8.x machine running ZFS and with a 3ware 9690SA controller. The 3ware controller shows an ECC-ERROR with one of the disks: //host> /c0 show VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 279.39 GB SAS 0 - SEAGATE ST3300657SS p1 OK u0 279.39 GB SAS 1 - SEAGATE ST3300657SS p2 OK u1 931.51 GB SAS 2 - SEAGATE ST31000640SS p3 ECC-ERROR u2 931.51 GB SAS 3 - SEAGATE ST31000640SS p4 OK u3 931.51 GB SAS 4 - SEAGATE ST31000640SS /c0 show events shows no ECC errors in it's recent history. ZFS does not currently detect any errors. zpool status says No known data errors My question: Is this ECC-ERROR something that I need to be concerned about? According to the 3ware CLI 9.5.2 Manual, an ECC-ERROR means that the 3ware controller caught a read-error for one or more sectors on this drive. This sometimes occurs when a RAID array is recovering from a failed disk. I believe that ECC-ERRORS can also be detected when the 3ware Controller verifies each disk. None of the drives have failed and thus there was no drive rebuild, so I assume that 3ware discovered a bad sector when it ran it's weekly auto-verify scan of the disks. Is this a safe assumption? According to our logs, ZFS has not detected any bad sectors on this drive. ZFS can work around read errors -- if ZFS detects a bad sector on the drive, it will simply mark that sector as bad and never use it again. From the ZFS perspective one bad sector isn't a big deal, although it might indicate that the drive is starting to go bad.

    Read the article

  • Nvidia GTS 360M in Asus laptop shuts off when gaming on external display

    - by mr odus
    I have had this problem on my Asus G51j Intel I5, Nvidia GTS360M graphics card. Just updated the drivers to latest off Nvidias site. Most games I play, If I hook it up through an external monitor(this happens whether it's HDMI or VGA). The laptop hard shuts down after about 20 minutes, give or take. This tends to happen on more graphically intense games like Call of dutys, bioshock. I'm running Windows 7, latest nvidia drivers. Games work fine on my laptops screen, and Movies, general computing work fine on the external displays. The laptop always sits on a cooling pad and the latest time was in front of my AC unit, I ran heatfan or whatever the heat tracking software was, and my temperatures were normal through a shut down. This has been happening for the life of the laptop. I dont play very many games, and even fewer on an external monitor, so this issue doesnt come up much Is it possible I have a faulty graphics card? Is there anything else I can try?

    Read the article

  • Convert mp4 video to a format xbox 360 can play

    - by Björn Lindqvist
    Here is a video file my Xbox 360 refuses to play: $ MP4Box -info video.mp4 * Movie Info * Timescale 90000 - Duration 02:18:33.365 Fragmented File no - 2 track(s) File Brand mp42 - version 0 Created: GMT Sat Jul 21 07:08:55 2012 File has root IOD (9 bytes) Scene PL 0xff - Graphics PL 0xff - OD PL 0xff Visual PL: ISO Reserved Profile (0x7f) Audio PL: High Quality Audio Profile @ Level 2 (0x0f) No streams included in root OD iTunes Info: Encoder Software: HandBrake 0.9.6 2012022800 Track # 1 Info - TrackID 1 - TimeScale 90000 - Duration 02:18:33.235 Media Info: Language "Undetermined" - Type "vide:avc1" - 199318 samples Visual Track layout: x=0 y=0 width=1280 height=688 MPEG-4 Config: Visual Stream - ObjectTypeIndication 0x21 AVC/H264 Video - Visual Size 1280 x 688 AVC Info: 1 SPS - 1 PPS - Profile High @ Level 4.1 NAL Unit length bits: 32 Self-synchronized Track # 2 Info - TrackID 2 - TimeScale 48000 - Duration 02:18:33.365 Media Info: Language "English" - Type "soun:mp4a" - 389689 samples MPEG-4 Config: Audio Stream - ObjectTypeIndication 0x40 MPEG-4 Audio MPEG-4 Audio AAC LC - 6 Channel(s) - SampleRate 48000 Synchronized on stream 1 $ avconv -i video.mp4 avconv version 0.8.4-4:0.8.4-0ubuntu0.12.04.1, Copyright (c) 2000-2012 the Libav developers built on Nov 6 2012 16:51:33 with gcc 4.6.3 Input #0, mov,mp4,m4a,3gp,3g2,mj2, from 'video.mp4': Metadata: major_brand : mp42 minor_version : 0 compatible_brands: mp42isomavc1 creation_time : 2012-07-21 07:08:55 encoder : HandBrake 0.9.6 2012022800 Duration: 02:18:33.36, start: 0.000000, bitrate: 2299 kb/s Stream #0.0(und): Video: h264 (High), yuv420p, 1280x688, 1973 kb/s, 23.98 fps, 90k tbr, 90k tbn, 180k tbc Metadata: creation_time : 2012-07-21 07:08:55 Stream #0.1(eng): Audio: aac, 48000 Hz, 5.1, s16, 319 kb/s Metadata: creation_time : 2012-07-21 07:08:55 At least one output file must be specified What tool, such as ffmpeg or mencoder, and what magic command line incantation should I use to transcode this file into a format Xbox 360 can play? I want the transcode process to retain as good video quality as possible.

    Read the article

  • Cooling Server Closet - No A/C Is Possible

    - by JamesCo
    We're moving into a new office in an old building in London (that's England :) and are walling off a 2m x 1.3m area where the router & telephone equipment currently terminates to use as a server closet. The closet will contain: 2 24-port switches 1 router 1 VSDL modem 1 Dell desktop 1 4-bay NAS 1 HP micro-server 1 UPS Miscellaneous minor telephony boxes. There is no central A/C in the office and there never will be. We can install ducting to the outside quite easily - it's only a couple of metres to the windows, which face a courtyard. My question is whether installing an extractor fan with ducting to the window should be sufficient for cooling? Would an intake fan and intake duct (from the window, too) be required? We don't want to leave a gap in the closet door as that'll let noise out into the office. If we don't have to put a portable A/C unit into the closet, that'd be perfect. The office has about 12 people; London is temperate, average maximum in August is 31 Celsius, 25 Celsius is more typical. The same equipment runs fine in our current office (same building as new office, also no A/C) but it isn't in an enclosed space. I can see us putting say one Dell 2950 tower server into the closet, but no more than that. So, sustained power consumption in the closet would currently be about 800w (I'm guessing); possibly in the future 2kw. The closet will have a ceiling and no windows and be well-insulated. We don't care if the equipment runs hot, so long as it runs and we don't hear it.

    Read the article

  • Copying SD Cards with "LaCie d2 Network"

    - by rjstelling
    The LaCie d2 Network has a feature where by you can attach a USB drive and press the blue button at the from and it will copy the drive contents (no computer required). (See this review for more info). USB 2.0 and eSATA ports are also provided but these are not designed for extending the d2 Network's storage. Rather, they allow you to connect portable drives for uploading their data to the d2 Network directly. The process is quite slick, too: just plug in a drive and press the big blue button on the front of the unit to trigger an immediate upload. This copies over everything on the external device and seems ideal for camera use. Is it possible to use an microSD or SD card adapter (like the Kingston MobileLite 9-in-1) and copy the contents of the card? I'm assuming the card reader just "looks like" a normal USB flash drive the computer or (in this case) LaCie d2 Network. Is this assumption correct? Do you know any reason why this won't work?

    Read the article

  • Importing csv list of contacts into Exchange 2007 GAL and create Distribution Group

    - by Ken Ray
    Here's the situation: We have a list of about 1,000 contacts (Lawyers in the area our court serves) with name and email address. I've been asked to create an email distribution list that can be used to sent emails to all of the external users on that list. I've seen various articles using the Exchange Management Shell and the Import-csv command piped through a ForEach-Object to a New-MailContact to set up the contacts. However, Exchange Management Shell is rather unhelpful, and it isn't working. What I believe I need to do is: 1) Set up a new distribution group using the Exchange Management Console. Let's say this new distribution group (which appears in the list of Distribution Groups under Recipient Configuration) is called "FloridaBar". 2) Make sure I have a csv file of the information I want to import. 3) Open Exchange Management Shell, and enter the following command: Import-csv C:\filename.csv | ForEach-Object { New-MailContact -Name $."NameColumnName" -ExternalEmailAddress $."EmailAddressColumn" -org FloridaBar Now, creating 1,000+ contacts in active directory - I assume that shouldn't be an issue. Do I have the "-org" parm wrong? Do I need to spell out the complete organization unit name (my.domain.name/Users/FloridaBar)? Is there a better way of doing this? Thanks in advance Ken

    Read the article

  • Linux Sound Drivers - Recompiling kernel with ehcd-hcd module

    - by jhome
    I just installed Linux Mint and I am trying to get my usb soundcard to work. I am completely new to Linux so I have only been learning about all the important parts of the OS this afternoon. No one I know has compiled kernel so I can't ask anyone. I am following instructions on this site: http://wiki.ubuntuusers.de/Benutzer/BigMc#Final-setup-of-US-122L-US-144 "Recompile your Kernel with ehcd-hcd as a module: Instructions for Ubuntu (german) Change "Device Drivers - USB support - EHCI HCD (USB 2.0) support)" to "M" when configuring. Make sure you also install the kernel headers." I know how to do any of these processes. Someone mentioned a package manager. Is recompiling basically in layman's terms reinstallation? Where do I go to the change device drivers? Cheers Edit: I am attempting to be able to use my Tascam US-144 on Linux Mint. Apparently, to use it properly it has to regress to functionality of a former unit (US-122), so according to the instructions a USB port has to be USB 1.0, rather than USB 2.0. I've tried using that ndis** programme for wireless drivers but with no success.

    Read the article

  • Symantec Endpoint Protection Virus Definitions

    - by Gus Denton
    I have done some Googling but I cannot get a definitive answer certainly not from the Symantec KB. I have a Virtualised Win 2003R2 server 32bit. It has been provisioned to me with Symantec Endpoint Protection 11.0.62xxx CLIENT (not a definitions server) the directory C:\Program Files\Common Files\Symantec Shared\VirusDefs is 750MB IT doesn't contain .tmp directories so it is NOT a corrupt definitions server. IT does contain directories named with a date pattern YYYYMMDD.xxx Some of these folders are 12 months old and I would like to recover the space. The sysmantect forums are full of this stuff but a lot of the postings contain links back to documents that are not specific to End Point Protection Client. It appears that I should be able to delete the older folders and all will be OK. with a service restart however there is a warning about having Live Update Administrator Installed Firstly I have no idea if I have this installed how to I check and secondly can I just ditch these old files and restart ? Regards Gus Denton Learning and Teaching Uni of New South Wales Sydney Australia For those trying to assist me I thankyou. I have followed some instructions found on the Symantec site and assumed that the response from Nixphoe would resolve my issue. It appears that as I am on a provisioned VM from a central IT unit I cannot run the Symantec commands from the Run prompt as my admin creds to get me in. (smc -stop) Basically I need to claw back some Diskspace from the c: drive which is being filed up with WSUS patches and Symantec files. I have managed to delete one symantec cache through the live update control panel and recovered 470Mb I suppose my last question for those more experienced than myself is, can I simply remove say the two oldest virus definition folders without completely foobaring the End Point protection and the server ? Regards Gus

    Read the article

< Previous Page | 186 187 188 189 190 191 192 193 194 195 196 197  | Next Page >