Search Results

Search found 3044 results on 122 pages for 'apc smart ups'.

Page 2/122 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • apcupsd on Linux does not report on APC BackUPS Pro 900

    - by lserni
    From what documentation I could find, the UPS should be (is!) supported by Linux and ought to work with apcupsd. I looked for specific problems such as the infamous Microlink protocol, and found none. I have found a feedback from a guy in UK that reports using this very model on a not-too-different OS version (his OpenSuSE 12.1, mine 12.3 x86_64). The USB port is detected, lsusb reports Bus 002 Device 003: ID 051d:0002 American Power Conversion Uninterruptible Power Supply and lsusb -v -s002:003 confirms and expands: Bus 002 Device 003: ID 051d:0002 American Power Conversion Uninterruptible Power Supply Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x051d American Power Conversion idProduct 0x0002 Uninterruptible Power Supply bcdDevice 0.90 iManufacturer 1 American Power Conversion iProduct 2 Back-UPS RS 900G FW:879.L4 .I USB FW:L4 bNumConfigurations 1 Configuration Descriptor: [...] Interface Descriptor: [...] bInterfaceClass 3 Human Interface Device bInterfaceSubClass 0 No Subclass bInterfaceProtocol 0 None iInterface 0 HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.00 bCountryCode 33 US bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 1134 Report Descriptors: ** UNAVAILABLE ** Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 100 Device Status: 0x0000 (Bus Powered) The kernel recognizes this and duly sets up crw------- 1 root root 180, 96 Nov 4 16:11 /dev/usb/hiddev0 As far as I know, everything is as it should be. I have put the standard configuration in /etc/apcupsd/apcupsd.conf (which is Unix-terminated, ASCII-only, no BOM (just in case)) UPSCABLE usb UPSTYPE usb DEVICE (I have also tried commenting out DEVICE, and setting a device of /dev/puppa results in an access attempt to /dev/puppa, not some /var/lib/dev/puppa or /dev/puppa\r\n). Yet, what apcaccess tells me is VERSION : 3.14.10 (13 September 2011) suse CABLE : USB Cable DRIVER : USB UPS Driver UPSMODE : Stand Alone STARTTIME: 2013-11-04 16:24:22 +0100 MODEL : STATUS : NOBATT LINEV : 000.0 Volts LOADPCT : 0.0 Percent Load Capacity BCHARGE : 000.0 Percent TIMELEFT : 0.0 Minutes MBATTCHG : 5 Percent MINTIMEL : 3 Minutes MAXTIME : 0 Seconds SENSE : Low LOTRANS : 000.0 Volts HITRANS : 000.0 Volts It doesn't recognize the model, and reports no battery (and no voltage). This confirms that it's not the Microlink problem, or it would report the battery status, if precious little else. If I disconnect the USB cable, I get an apcupsd message to the effect that communications have been lost; and I get the "communication restored" broadcast too, if I reconnect the cable. apcupsd is monitoring. So everything tells me that it should work -- only it doesn't. Does anyone spot what I'm missing?

    Read the article

  • The Benefits of Smart Grid Business Software

    - by Sylvie MacKenzie, PMP
    Smart Grid Background What Are Smart Grids?Smart Grids use computer hardware and software, sensors, controls, and telecommunications equipment and services to: Link customers to information that helps them manage consumption and use electricity wisely. Enable customers to respond to utility notices in ways that help minimize the duration of overloads, bottlenecks, and outages. Provide utilities with information that helps them improve performance and control costs. What Is Driving Smart Grid Development? Environmental ImpactSmart Grid development is picking up speed because of the widespread interest in reducing the negative impact that energy use has on the environment. Smart Grids use technology to drive efficiencies in transmission, distribution, and consumption. As a result, utilities can serve customers’ power needs with fewer generating plants, fewer transmission and distribution assets,and lower overall generation. With the possible exception of wind farm sprawl, landscape preservation is one obvious benefit. And because most generation today results in greenhouse gas emissions, Smart Grids reduce air pollution and the potential for global climate change.Smart Grids also more easily accommodate the technical difficulties of integrating intermittent renewable resources like wind and solar into the grid, providing further greenhouse gas reductions. CostsThe ability to defer the cost of plant and grid expansion is a major benefit to both utilities and customers. Utilities do not need to use as many internal resources for traditional infrastructure project planning and management. Large T&D infrastructure expansion costs are not passed on to customers.Smart Grids will not eliminate capital expansion, of course. Transmission corridors to connect renewable generation with customers will require major near-term expenditures. Additionally, in the future, electricity to satisfy the needs of population growth and additional applications will exceed the capacity reductions available through the Smart Grid. At that point, expansion will resume—but with greater overall T&D efficiency based on demand response, load control, and many other Smart Grid technologies and business processes. Energy efficiency is a second area of Smart Grid cost saving of particular relevance to customers. The timely and detailed information Smart Grids provide encourages customers to limit waste, adopt energy-efficient building codes and standards, and invest in energy efficient appliances. Efficiency may or may not lower customer bills because customer efficiency savings may be offset by higher costs in generation fuels or carbon taxes. It is clear, however, that bills will be lower with efficiency than without it. Utility Operations Smart Grids can serve as the central focus of utility initiatives to improve business processes. Many utilities have long “wish lists” of projects and applications they would like to fund in order to improve customer service or ease staff’s burden of repetitious work, but they have difficulty cost-justifying the changes, especially in the short term. Adding Smart Grid benefits to the cost/benefit analysis frequently tips the scales in favor of the change and can also significantly reduce payback periods.Mobile workforce applications and asset management applications work together to deploy assets and then to maintain, repair, and replace them. Many additional benefits result—for instance, increased productivity and fuel savings from better routing. Similarly, customer portals that provide customers with near-real-time information can also encourage online payments, thus lowering billing costs. Utilities can and should include these cost and service improvements in the list of Smart Grid benefits. What Is Smart Grid Business Software? Smart Grid business software gathers data from a Smart Grid and uses it improve a utility’s business processes. Smart Grid business software also helps utilities provide relevant information to customers who can then use it to reduce their own consumption and improve their environmental profiles. Smart Grid Business Software Minimizes the Impact of Peak Demand Utilities must size their assets to accommodate their highest peak demand. The higher the peak rises above base demand: The more assets a utility must build that are used only for brief periods—an inefficient use of capital. The higher the utility’s risk profile rises given the uncertainties surrounding the time needed for permitting, building, and recouping costs. The higher the costs for utilities to purchase supply, because generators can charge more for contracts and spot supply during high-demand periods. Smart Grids enable a variety of programs that reduce peak demand, including: Time-of-use pricing and critical peak pricing—programs that charge customers more when they consume electricity during peak periods. Pilot projects indicate that these programs are successful in flattening peaks, thus ensuring better use of existing T&D and generation assets. Direct load control, which lets utilities reduce or eliminate electricity flow to customer equipment (such as air conditioners). Contracts govern the terms and conditions of these turn-offs. Indirect load control, which signals customers to reduce the use of on-premises equipment for contractually agreed-on time periods. Smart Grid business software enables utilities to impose penalties on customers who do not comply with their contracts. Smart Grids also help utilities manage peaks with existing assets by enabling: Real-time asset monitoring and control. In this application, advanced sensors safely enable dynamic capacity load limits, ensuring that all grid assets can be used to their maximum capacity during peak demand periods. Real-time asset monitoring and control applications also detect the location of excessive losses and pinpoint need for mitigation and asset replacements. As a result, utilities reduce outage risk and guard against excess capacity or “over-build”. Better peak demand analysis. As a result: Distribution planners can better size equipment (e.g. transformers) to avoid over-building. Operations engineers can identify and resolve bottlenecks and other inefficiencies that may cause or exacerbate peaks. As above, the result is a reduction in the tendency to over-build. Supply managers can more closely match procurement with delivery. As a result, they can fine-tune supply portfolios, reducing the tendency to over-contract for peak supply and reducing the need to resort to spot market purchases during high peaks. Smart Grids can help lower the cost of remaining peaks by: Standardizing interconnections for new distributed resources (such as electricity storage devices). Placing the interconnections where needed to support anticipated grid congestion. Smart Grid Business Software Lowers the Cost of Field Services By processing Smart Grid data through their business software, utilities can reduce such field costs as: Vegetation management. Smart Grids can pinpoint momentary interruptions and tree-caused outages. Spatial mash-up tools leverage GIS models of tree growth for targeted vegetation management. This reduces the cost of unnecessary tree trimming. Service vehicle fuel. Many utility service calls are “false alarms.” Checking meter status before dispatching crews prevents many unnecessary “truck rolls.” Similarly, crews use far less fuel when Smart Grid sensors can pinpoint a problem and mobile workforce applications can then route them directly to it. Smart Grid Business Software Ensures Regulatory Compliance Smart Grids can ensure compliance with private contracts and with regional, national, or international requirements by: Monitoring fulfillment of contract terms. Utilities can use one-hour interval meters to ensure that interruptible (“non-core”) customers actually reduce or eliminate deliveries as required. They can use the information to levy fines against contract violators. Monitoring regulations imposed on customers, such as maximum use during specific time periods. Using accurate time-stamped event history derived from intelligent devices distributed throughout the smart grid to monitor and report reliability statistics and risk compliance. Automating business processes and activities that ensure compliance with security and reliability measures (e.g. NERC-CIP 2-9). Grid Business Software Strengthens Utilities’ Connection to Customers While Reducing Customer Service Costs During outages, Smart Grid business software can: Identify outages more quickly. Software uses sensors to pinpoint outages and nested outage locations. They also permit utilities to ensure outage resolution at every meter location. Size outages more accurately, permitting utilities to dispatch crews that have the skills needed, in appropriate numbers. Provide updates on outage location and expected duration. This information helps call centers inform customers about the timing of service restoration. Smart Grids also facilitates display of outage maps for customer and public-service use. Smart Grids can significantly reduce the cost to: Connect and disconnect customers. Meters capable of remote disconnect can virtually eliminate the costs of field crews and vehicles previously required to change service from the old to the new residents of a metered property or disconnect customers for nonpayment. Resolve reports of voltage fluctuation. Smart Grids gather and report voltage and power quality data from meters and grid sensors, enabling utilities to pinpoint reported problems or resolve them before customers complain. Detect and resolve non-technical losses (e.g. theft). Smart Grids can identify illegal attempts to reconnect meters or to use electricity in supposedly vacant premises. They can also detect theft by comparing flows through delivery assets with billed consumption. Smart Grids also facilitate outreach to customers. By monitoring and analyzing consumption over time, utilities can: Identify customers with unusually high usage and contact them before they receive a bill. They can also suggest conservation techniques that might help to limit consumption. This can head off “high bill” complaints to the contact center. Note that such “high usage” or “additional charges apply because you are out of range” notices—frequently via text messaging—are already common among mobile phone providers. Help customers identify appropriate bill payment alternatives (budget billing, prepayment, etc.). Help customers find and reduce causes of over-consumption. There’s no waiting for bills in the mail before they even understand there is a problem. Utilities benefit not just through improved customer relations but also through limiting the size of bills from customers who might struggle to pay them. Where permitted, Smart Grids can open the doors to such new utility service offerings as: Monitoring properties. Landlords reduce costs of vacant properties when utilities notify them of unexpected energy or water consumption. Utilities can perform similar services for owners of vacation properties or the adult children of aging parents. Monitoring equipment. Power-use patterns can reveal a need for equipment maintenance. Smart Grids permit utilities to alert owners or managers to a need for maintenance or replacement. Facilitating home and small-business networks. Smart Grids can provide a gateway to equipment networks that automate control or let owners access equipment remotely. They also facilitate net metering, offering some utilities a path toward involvement in small-scale solar or wind generation. Prepayment plans that do not need special meters. Smart Grid Business Software Helps Customers Control Energy Costs There is no end to the ways Smart Grids help both small and large customers control energy costs. For instance: Multi-premises customers appreciate having all meters read on the same day so that they can more easily compare consumption at various sites. Customers in competitive regions can match their consumption profile (detailed via Smart Grid data) with specific offerings from competitive suppliers. Customers seeing inexplicable consumption patterns and power quality problems may investigate further. The result can be discovery of electrical problems that can be resolved through rewiring or maintenance—before more serious fires or accidents happen. Smart Grid Business Software Facilitates Use of Renewables Generation from wind and solar resources is a popular alternative to fossil fuel generation, which emits greenhouse gases. Wind and solar generation may also increase energy security in regions that currently import fossil fuel for use in generation. Utilities face many technical issues as they attempt to integrate intermittent resource generation into traditional grids, which traditionally handle only fully dispatchable generation. Smart Grid business software helps solves many of these issues by: Detecting sudden drops in production from renewables-generated electricity (wind and solar) and automatically triggering electricity storage and smart appliance response to compensate as needed. Supporting industry-standard distributed generation interconnection processes to reduce interconnection costs and avoid adding renewable supplies to locations already subject to grid congestion. Facilitating modeling and monitoring of locally generated supply from renewables and thus helping to maximize their use. Increasing the efficiency of “net metering” (through which utilities can use electricity generated by customers) by: Providing data for analysis. Integrating the production and consumption aspects of customer accounts. During non-peak periods, such techniques enable utilities to increase the percent of renewable generation in their supply mix. During peak periods, Smart Grid business software controls circuit reconfiguration to maximize available capacity. Conclusion Utility missions are changing. Yesterday, they focused on delivery of reasonably priced energy and water. Tomorrow, their missions will expand to encompass sustainable use and environmental improvement.Smart Grids are key to helping utilities achieve this expanded mission. But they come at a relatively high price. Utilities will need to invest heavily in new hardware, software, business process development, and staff training. Customer investments in home area networks and smart appliances will be large. Learning to change the energy and water consumption habits of a lifetime could ultimately prove even more formidable tasks.Smart Grid business software can ease the cost and difficulties inherent in a needed transition to a more flexible, reliable, responsive electricity grid. Justifying its implementation, however, requires a full understanding of the benefits it brings—benefits that can ultimately help customers, utilities, communities, and the world address global issues like energy security and climate change while minimizing costs and maximizing customer convenience. This white paper is available for download here. For further information about Oracle's Primavera Solutions for Utilities, please read our Utilities e-book.

    Read the article

  • APC UPS-5000 Power off remote servers

    - by Vishal
    Hi there, I have a UPS connected via the serial port to a server using PowerChute Business Edition. If a power outage occurs I would like this server to start shutting down all other servers within the network. Is there dedicated software to do this? I was thinking of creating a command file which runs a .bat file to run shut down commands to each server (using PSExec). I can set PowerChute to run this command file when a power failure occurs. Is there not anything APC provide which has this functionality and is more efficient than writing a .bat file to do this? Thanks,

    Read the article

  • nut (UPS) and SSL certificates

    - by Mausy5043
    Today I installed nut on my Ubuntu server (14.03). $ uname -a Linux boson 3.13.0-24-generic #47-Ubuntu SMP Fri May 2 23:30:00 UTC 2014 x86_64 x86_64 x86_64 GNU/Linux The UPS is connected to another server (called neutron), so I use nut-client to keep tabs on the UPS state. When I do sudo upsc [email protected] I get: Init SSL without certificate database battery.charge: 15 battery.charge.low: 10 battery.charge.warning: 50 battery.date: not set battery.mfr.date: 2012/11/27 : The first line of the output concerns me. I've not seen this on other installations of nut on Debian-based servers. What can I do to get rid of that line? EDIT: This "Init SSL without certificate database" is extra annoying because it is not part of the output of upsc and therefore I cannot grep it out.

    Read the article

  • Error at the end of APC install

    - by cinqoTimo
    I need to get APC running for a Drupal install of mine. I found a fairly concise guide at http://blog.4rev.net/2009-09/installing-apc-accelerator-into-php5-fedora-core-11/ for installing on FC11, only, I am using FC12. I figured I would give it a shot. I was able to run the following commands successfully - and yum installed fc12 versions of everything in the FC11 guide. yum install php-pear yum install php-devel httpd-devel yum groupinstall ‘Development Tools’ yum groupinstall ‘Development Libraries’ Then, I tried pecl install apc. Everything looked good until to got to the end, where it outputted the following error. /var/tmp/APC/php_apc.c: In function ‘zif_apc_compile_file’: /var/tmp/APC/php_apc.c:881: warning: unused variable ‘eg_class_table’ /var/tmp/APC/php_apc.c:881: warning: unused variable ‘eg_function_table’ /var/tmp/APC/php_apc.c: At top level: /var/tmp/APC/php_apc.c:959: error: duplicate ‘static’ make: *** [php_apc.lo] Error 1 ERROR: `make' failed Some people have had success with installing apc-beta, but that didn't work for me.. Any suggestions? Is there something I missed that is critical in the FC12 version?

    Read the article

  • PHP unable to start if "apc.shm_size" has "M" or "G" unit

    - by apasajja
    Using: Ubuntu 10.04, PHP 5.3.10, apc 3.1.3 PHP and APC installed using below repo: deb http://ppa.launchpad.net/brianmercer/php5/ubuntu lucid main deb-src http://ppa.launchpad.net/brianmercer/php5/ubuntu lucid main If I put apc.shm_size=3G or apc.shm_size=3000M in /etc/php5/fpm/conf.d/apc.ini, PHP unable to start. However, if I put only number without M or G unit, it will start and run. By default, if put only number, what unit is it means? It I put 3000 does it means 3000 MB?

    Read the article

  • Configure APC for maximum hit rate

    - by Steven De Groote
    I'm currently running php5 with APC, the latter with default configuration. However after setting up munin to monitor APC, I'm surprised by the results: apc.shm_size: 30 apc.gc_ttl: 3600 apc.ttl: 0 Used: 14MB Request rate: 100 requests/second Fragmentation: 0 Hit ratio: 80% (dropping to 0 a few times per hour) So the obvious question: how can I adapt the configuration to achieve a higher hitrate. I find it very strange that the available memory is not fully used which the hitratio is still below what I would expect. Thank for any hints!

    Read the article

  • UPS with a HP Proliant server

    - by Groo
    We placed a EATON Ellipse Max 1500 (900W) as the UPS for our HP Proliant ML350 G6. Upon first power failure (actually we only moved the UPS' input plug to a different socket), server immediatelly turned off, and the Health LED turned red and started blinking. UPS was in operation for about a week before that, with battery fully charged to 100%. Since our server's hot-plug supply is 460W, we are pretty sure we haven't overloaded it, the server was completely idle at that time (no web or win apps running except Windows Server core services). Then we tried to do the same with a different, no-name older PC (Core 2 Duo, 2Gb RAM) with a generic power supply (not sure what the power is) and it continued working when we pulled the plug out. UPS load was less than 15% (measured in the provided Eaton utility). We measured the UPS' output voltage using a smart oscilloscope and the THD of the UPS output waveform turned out to be 40%. Did you have similar experiences? Could this be a faulty UPS? Or a faulty power supply? Or some HP sensors configured to trigger too strictly? I wouldn't like replacing this UPS with the same brand, to get same results. [Edit] I also tried to do this while the server is turned off. While the UPS is working on battery, server will not start - as soon as I press the power button, Health LED starts blinking red.

    Read the article

  • Windows server 2008 UPS support

    - by Rory McCune
    I'm looking to set-up a UPS on a Windows Small Business Berver 2k8 and I've noticed that there are some large price differences for similar capacity in-line UPSs. The most important point for me in UPS selection is that the server should have the ability to shut itself down before the UPS power runs out, so that if the server is unattended during the outage, it should minimize the risk of data loss. From some reading it appears that Windows Server 2008 should has the ability to natively recognise a UPS, which can then be managed through the battery settings on the server or via WMI. What I'm wondering if anyone know is, Is Windows 2008 servers UPS support specific to certain brands of UPS (eg, APC) or is it likely to work with any UPS which has a USB port, which I can connect to the server?

    Read the article

  • Radiation from a UPS

    - by Erel Segal
    In our office, there are frequent eletric shortages that harm my desktop computer, so I wanted to install a UPS. However, my office-mates pointed me to papers talking about hazardous radiation from the UPS. The UPS manufacturers themselves recommend to put the UPS several meters away from humans, which is not possible because our office is small (the power is about 0.5 meters from us). As an alternative to UPS, my office-mates recommended that I switch to a laptop, which has a battery so it's immune to shortages. I have several questions: Is it true that the radiation from a laptop battery is lower than the radiation from a UPS? They do just the same thing - supply power using a battery! If the answer to 1 is yes - is there an alternative way to attach a battery, similar to a laptop battery, to a desktop computer? If the answer to 1 is no - how can I prove this to my office-mates, so that they let me use UPS?

    Read the article

  • Can an UPS be too powerful?

    - by Andy
    Our old network admin bought the top range UPS a few months ago but never came around to setting it up and is no longer with the company. Now the old UPS broke down and needs to be replaced, but an external company that did an audit said that that UPS won't work. Now we are no hardware specialists, but the difference in specs is a higher output from 5A to 8.8A meaning a higher output. But isn't the UPS supposed to give the server the required output anyway? This 'independent' audit does sell its own hardware including UPSes so I'm not sure how much bias they have. Is there a reason why we can't replace the old broken UPS with the new more powerful one? Is there a way we can check to see if the UPS works with our server? ok, i wrote down the numbers again, the Volts and Amps are what are on the back (where you connect up the plugs which seem diffrent from on the front label.) old one APC SmartUPS 1500 220-240V -- 6.8A new one Dell UPS 1920W 250V -- 10A

    Read the article

  • Smart Help with UPK

    - by [email protected]
    A short lesson on how awesome Smart Help is. In Oracle UPK speak, there are targeted and non-targeted applications. Targeted applications are Oracle EBS, PeopleSoft, Siebel, JD Edwards, SAP and a few others. Non-targeted applications are either custom built or other third party off the shelf applications. For most targeted applications you'll see better object recognition (during recording) and also Help Integration for that application. Help integration means that someone technical modifies the help link in your application to call up the UPK content that has been created. If you have seen this presented before, this is usually where the term context sensitive help is mentioned and the Do It mode shows off. The fact that UPK builds context sensitive help for its targeted applications automatically is awesome enough, but there is a whole new world out there and it's called "custom and\or third party apps." For the purposes of Smart Help and this discussion, I'm talking about the browser based applications. How does UPK support these apps? It used to be that you had to have your vendor try to modify the Help link to point to UPK or if your company had control over the applications configuration menus, then you get someone on your team to modify this for you. But as you start to use UPK for more than one, two or three applications, the administration of this starts to become daunting. Multiple administrators, multiple player packages, multiple call points, multiple break points, help doesn't always work the same way for every application (picture the black white infomercial with an IT person trying to configure a bunch of wires or something funny like that). Introducing Smart Help! (in color of course, new IT person, probably wearing a blue shirt and smiling). Smart help eliminates the need to configure multiple browser help integration points, and adds a icon to the users browser itself. You're using your browser to read this now correct? Look up at the icons on your browser, you have the home link icon, print icon, maybe an RSS feed icon. Smart Help is icon that gets added to the users browser just like the others. When you click it, it first recognizes which application you're in and then finds the UPK created material for you and returns the best possible match, for (hold on to your seat now) both targeted and non-targeted applications (browser based applications). But wait, there's more. It does this automatically! You don't have to do anything! All you have to do is record content, UPK and Smart Help do the rest! This technology is not new. There are customers out there today that use this for as many as six applications! The real hero here is SMART MATCH. Smart match is the technology that's used to determine which application you're in and where you are when you click on Smart Help. We'll save that for a one-on-one conversation. Like most other awesome features of UPK, it ships with the product. All you have to do is turn it on. To learn more about Smart Help, Smart Match, Targeted and Non-Targeted applications, contact your UPK Sales Consultant or me directly at [email protected]

    Read the article

  • WD1000FYPS harddrive is marked 0 mb in 3ware (and no SMART)

    - by osgx
    After reboot my SATA 1TB WD1000FYPS (previously is was "Drive error") is marked 0 mb in 3ware web gui. Complete message: Available Drives (Controller ID 0) Port 1 WDC WD1000FYPS-01ZKB0 0.00 MB NOT SUPPORTED [Remove Drive] SMART gives me only Device Model and ATA protocol version 1 (not 7-8 as it must be for SATA) What does it mean? Just before reboot, when is was marked only with "Device Error", smart was: Device Model: WDC WD1000FYPS-01ZKB0 Serial Number: WD-WCASJ1130*** Firmware Version: 02.01B01 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Sun Mar 7 18:47:35 2010 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled SMART overall-health self-assessment test result: PASSED SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0003 188 186 021 Pre-fail Always - 7591 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 229 5 Reallocated_Sector_Ct 0x0033 199 199 140 Pre-fail Always - 3 7 Seek_Error_Rate 0x000e 193 193 000 Old_age Always - 125 9 Power_On_Hours 0x0032 078 078 000 Old_age Always - 16615 10 Spin_Retry_Count 0x0012 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0012 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 77 192 Power-Off_Retract_Count 0x0032 198 198 000 Old_age Always - 1564 193 Load_Cycle_Count 0x0032 146 146 000 Old_age Always - 164824 194 Temperature_Celsius 0x0022 117 100 000 Old_age Always - 35 196 Reallocated_Event_Count 0x0032 199 199 000 Old_age Always - 1 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 What can be wrong with he? Can it be restored? PS new smart is === START OF INFORMATION SECTION === Device Model: WDC WD1000FYPS-01ZKB0 Serial Number: [No Information Found] Firmware Version: [No Information Found] Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 1 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon Mar 8 00:29:44 2010 MSK SMART is only available in ATA Version 3 Revision 3 or greater. We will try to proceed in spite of this. SMART support is: Ambiguous - ATA IDENTIFY DEVICE words 82-83 don't show if SMART supported. Checking for SMART support by trying SMART ENABLE command. Command failed, ata.status=(0x00), ata.command=(0x51), ata.flags=(0x01) Error SMART Enable failed: Input/output error SMART ENABLE failed - this establishes that this device lacks SMART functionality. A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options. PPS There was a rapid grow of " 192 Power-Off_Retract_Count " before dying. The hard was used in raid, with several hards from the same fabric packaging box (close id's). The hard drives were placed identically. Rapid means almost linear grow from 300 to 1700 in 6-7 hours. Maximal temperature was 41C. (thanks to munin's smart monitoring)

    Read the article

  • Install APC on Windows

    - by jiewmeng
    how can i install APC on Windows? i am using PHP 5.3, Windows 7 x64 i used pecl install apc i got C:\PHPpecl install apc downloading APC-3.0.19.tgz ... Starting to download APC-3.0.19.tgz (115,735 bytes) ............done: 115,735 bytes 47 source files, building WARNING: php_bin c:\php\php.exe appears to have a suffix \php.exe, but config variable php_suffix does not match running: msdev APC.dsp /MAKE "APC - Release" ERROR: Did not understand the completion status returned from msdev.exe.

    Read the article

  • APC Not Enabled (WHM on CentOS)

    - by gamerzfuse
    I know this questions has been beat to death, but I've read almost all the responses and it hasn't solved my issue. I installed APC (no noted errors), I told PHP.ini to enable it and I made sure I am running PHP in FastCGI with SuExec turned off. Still I have no go. PHP / suEXEC Configuration Default PHP Version (.php files) 5 PHP 5 Handler fcgi PHP 4 Handler none Apache suEXEC off Apache Ruid2 off php.ini Configuration Alternative PHP Cache apc.enabled Alternative PHP Cache apc.shm_segments Alternative PHP Cache apc.shm_size When I run the APC.php file I get this message: No cache info available. APC does not appear to be running.

    Read the article

  • Adding Liebert UPS (Uninterrupted power supply) psi Range

    - by Theuns
    I have an Liebert PowerSure PSI Line-Interactive UPS, 1000VA (DISCONTINUED) and using ubuntu lts 12.4 presice . I've used it on windows and it came up as and Notebooks battery. Is there support for these type of devices? any help Plz. I've tried the Multi link software on the emerson site and found 'ML_36_004_Linux_x86.bin' witch would be the software when using the 2.4.18+ Kernel . is it possible to use this file? Thank u

    Read the article

  • UPS - Two computers - How to get them to both shutdown when battery is low?

    - by hamlin11
    Short Version: How do I get 2 computers to shutdown when a UPS battery gets low? Long Version: I have an APC UPS, the RS 1500. It has a USB cord that goes into my main dev computer. My dev computer will shutdown when the battery gets low. However, in addition, I have now hooked up a database server to the same UPS. How can I have that database server also know that it needs to shut down when the battery gets low?

    Read the article

  • PHP-FPM and APC for shared hosting?

    - by Tiffany Walker
    We are looking into finding a way to get APC to only create one cache per account / site. This can be done with Fastcgi (last update 2006…) but with Fastcgid APC will have to create multiple caches for multiple processes run by the same account. To get around this problem, we have been looking into PHP-FPM PHP process manager allows multiple PHP processes to share a single APC cache. But from what I have read (I hope I'm wrong) , even if you create a pool per process, all sites accross all pools will share the same APC cache. This brings us back to the same problem as with shared Memcached: it's not secure ! On php-fpm's site I read that you can chroot php-fpm pools and define a specific UID and GID per pool… if this is the case then shouldn't APC have to use this user and not have access to other pools cache ? An article here (in 2011) suggests that you would need to run one process per pool creating multiple launchers on different ports and different config files with one pool per config file : http://groups.drupal.org/node/198168 Is this still neceessary ? If so what would be the impact of running say 800 processes of php-fpm ? Would it be mainly memory ? If so how can I work out what the memory impact would be ? I guess that it would be better to run 800 times php-fpm then to have accounts creating multiple APC caches for a single site ? If on average an account creates a 50MB cache and creates 3 caches per account that makes 150Mb per account which makes 120GB… However if each account uses on average only 50Mb that would make 40GB We will have at least 128GB of ram on our next server so 40GB is acceptable if running 800 x PHP-FPM does not create an overhead of more than 20GB ! What do you think is PHP-FPM the best way to go to provide secure APC cache on shared hosting with a server that has a decent amount of memory ? Or should I be looking at another system ? Thanks !

    Read the article

  • Is Tripp Lite a trusted brand for a UPS?

    - by David
    I am looking to buy a rack mounted UPS that can take in 208V power and serve up 120V power. A basic APC unit that can do this is $4k. I have found a Tripp Lite model that will work for $2.5k. Is the extra $1.5k for the APC just for the brand? Or will the Tripp Lite serve me just as well? Thanks!

    Read the article

  • How can I monitor a Smart-UPS 2200 in PRTG?

    - by dasaybz
    This UPS is connected via a serial cable to a server. I am trying to get the temperature readings off of the sensor that is connected to the UPS and get them in PRTG. We were able to do this in the past and then when we changed the server out, we lost the settings. Does anyone have any info that might help? Thanks!!

    Read the article

  • Praise for Europe's Smart Metering & Conservation Efforts

    - by caroline.yu
    Recently, a writer at the Home Energy Team praised the UK for its efforts towards smart metering and energy conservation, with an article entitled UK Blazing A Trail With Smart Metering At Home? The article highlighted that the Department of Energy and Climate Change has announced that smart metering will be introduced in the next decade and that all UK households will have smart meters by the year 2020. In fact, the UK is not the only country striving to achieve carbon reduction targets, as many of its European counterparts have begun to take positive steps towards tackling the issue of energy conservation by implementing innovative new metering and billing technologies as well as promoting alternative energy solutions, such as wind and solar power. Since 1997, the states of the European Union, including France, Germany and Spain, have been working towards achieving a target of 12 percent renewable energy electricity by 2010. Germany in particular has made a significant achievement so far, having surpassed the target early in 2007. This success is largely due to the German Renewable Energy Act (EEG), which promoted the use of renewable energy. Recently, analysis from the European Wind Energy Association (EWEA) found that 21 of the EU Member States are meeting or exceeding their national target to achieve 20 percent renewable energy by 2020. However, six states - Belgium, Italy, Luxembourg, Malta, Bulgaria and Denmark - say they will not manage to reach their target through domestic action alone. Bulgaria and Denmark believe that with fresh national initiatives they could meet or exceed their targets, but others, including Italy, may need to import renewable energy from neighboring non-EU countries. Top achievers, according to the EWEA report, are Spain, which believes its renewable energy will reach 22.7 percent by 2020, as well as Germany, Estonia, Greece, Ireland, Poland, Slovakia and Sweden, who will all exceed their targets. "Importantly, the way that this renewable energy is controlled and distributed must be addressed in order to ensure its success," said Bastian Fischer, vice president and general manager EMEA, Oracle Utilities. "A smart gird infrastructure can enable utilities to deal with load distribution in times of increased need and ensure power is always available from these means. A smart grid also underpins the success of metering and billing technologies, such as smart metering, and allows utilities to deal with increased usage data and provide accurate billing." Outside of Europe, Australia has made significant steps towards improving water conservation. The Australian Department of Sustainability and Environment took some of the recent advancements made in the energy sector, including new metering and billing solutions, and applied them to the water industry, enhancing customer service and reducing consumption as a result. The adoption of smart metering in Europe is mainly driven by regulation, but significant technological improvements are being made the world over to change the way we use all kinds of energy. However, the developing markets are lagging behind. One of the primary reasons for this is the lack of infrastructure in place to use as a foundation for setting up energy-saving solutions, which is slowing the adoption of technologies such as smart meters. However, these countries do benefit from fewer outdated infrastructure and legacy systems, which is often cited by others as a difficult barrier to deploying new solutions. As a result, some countries should find new technologies easier to implement and adapt to in the immediate future, without this roadblock.

    Read the article

  • Why is APC (PHP Accelerator) Only caching apc.php?

    - by amvx
    I installed PHP5,APC and XDEBUGGER with the install script found here: Dreamhost PHP+APC Install Instructions/Script All systems seem to be working... except... I added the apc.php to see the caching stats of APC (GUI Interface), and it showed that only apc.php file was being cached despite having installed wordpress and prestashop under the same domain, installing and running those php scripts. I wonder if I did something wrong... but my php5 is running as a cgi/fastcgi. I think I might have read somewhere about there being some issue with this. Not sure. Any help is of coursed appreciated.

    Read the article

  • APC module causing strange error

    - by clifgriffin
    When I run php -v I get: PHP Warning: PHP Startup: Unable to load dynamic library '/usr/lib64/php/modules/apc.so' - /usr/lib64/php/modules/apc.so: undefined symbol: php_pcre_exec in Unknown on line 0 This isn't my first rodeo. I've setup APC multiple times. This is a MediaTemple Dedicated Virtual 4.0 with Plesk 11. Plesk 11 is the only thing essentially different from the other servers I've set this up on. I've verified that pcre-devel is installed. I've compiled APC from source as well as used pecl to install it. No difference. I also tried downgrading to APC 3.0.19, with no love.

    Read the article

  • PHP-APC Installation

    - by Leo
    Trying to get my head around the way to install APC cache on PHP 5.3.13. That's a VPS with apache, configured preferably through whm/cpanel (although not only). I read a bunch of articles where it was suggested to use FastCGI with APC, as suPHP doens't do well with opcode caching, and fcgid_module doesn't do it right for APC either. Noted that fcgid_module is a newer package than FastCGI and that's what whm/cpanel installs for you but ok, that can be solved I guess. Then I'm reading that php-fpm is a much better alternative to manage the php processes, especially for APC. Ok. Then I realised that php-fpm is included in php core since 5.3 and got confused. Does that mean I don't have to use FastCGI/fcgid_module (and what should I use instead of them - mod_php or cgi?)? Or does that mean that I still need to get the older FastCGI module, and configure it to use one process per user (or just one process?)? Or would fcgid_module work as well? And how bad would it be just to go with mod_php/APC to avoid troubles of installing php-fpm and FastCGI (whm/cpanel doesn't support neither) given than Varnish would serve most of the static content anyway - no php process need to be created for static content. Any examples of their FastCGI/fcgid_module/php-fpm/APC configurations would be greatly appreciated as well.

    Read the article

  • What's So Smart About Oracle Exadata Smart Flash Cache?

    - by kimberly.billings
    Want to know what's so "smart" about Oracle Exadata Smart Flash Cache? This three minute video explains how Oracle Exadata Smart Flash Cache helps solve the random I/O bottleneck challenge and delivers extreme performance for consolidated database applications. Exadata Smart Flash Cache is a feature of the Sun Oracle Database Machine. With it, you get ten times faster I/O response time and use ten times fewer disks for business applications from Oracle and third-party providers. Read the whitepaper for more information. var gaJsHost = (("https:" == document.location.protocol) ? "https://ssl." : "http://www."); document.write(unescape("%3Cscript src='" + gaJsHost + "google-analytics.com/ga.js' type='text/javascript'%3E%3C/script%3E")); try { var pageTracker = _gat._getTracker("UA-13185312-1"); pageTracker._trackPageview(); } catch(err) {}

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >