  • How can one implement RAID1 with a Dell Latitude laptop containing one normal hard drive, and one hard drive in an external bay?

    - by user12583188
    OS: Win7 professional Laptop: latitude e6420 The answer to this question should address how to deploy RAID1 software wise on a dell latitude e6420. I have two Hitachi Z5K500 320GB drives (new). There is one hard drive (320GB capacity) in the system now, which contains the current installation that I would prefer to keep. The drive currently inside the laptop will be replaced with one of the Hitachi drives, and the other Hitachi drive will be fitted into the laptop by way of a Dell hard drive "caddy" enclosure, which inserts into the media bay of the laptop (you remove the cd-rom bay, insert hd-bay).

    Read the article

  • Disaster Recovery Plan&ndash;Rebuild System Disk (Dell Server 2900 with PERC RAID controller)

    - by Jim Lahman
    Goal: Since the system disk is a RAID 1 mirrored set, we can rebuild the shadow set by replacing one of the good sets with a blank disk Steps Shutdown and power down server Remove the disk from bay 9, which is part of the system shadow set. Put this disk on the shelf Insert blank/old disk into the empty bay     Label the new disk before inserting it into the empty bay       Power up server During the booting process, the following message appears: “Some configured disks have been removed from your system…”       Press ‘C’ to Load Configuration utility             Press 'Y' to confirm to load the foreign configuration       In this example, the system shadow set is Disk Group 2.  (Before proceeding, confirm this is the disk group in your case).  Expanding the physical disks shows a disk in bay 8 and a missing disk in bay 9.  This is correct.   Now, we have to include the new inserted disk in this group       RAID controller reporting bay 9 is empty       There may be times when the new disk is seen as a foreign disk.  In this case, do the following:     Foreign disk is reported in bay 9 CTRL-N (Next Page) to Foreign Mgt All the disk groups will be displayed.  Typically, the disk group containing the foreign disk will be grey.  To remove the foreign disk Highlight Controller Press F2 Select Foreign Select Clear (do NOT import the configuration!)       Clear the foreign configuration Now the disk can be brought into the system shadow set disk group as a hot spare   To include the newly inserted disk into the system shadowset disk group, it must be brought in as a hot spare Highlight Disk Group 2 (VD Management) Hit F2 Select 'Manage Ded. HS'     Manage dedicated hot swap Select the disk in bay 9 (Hit space bar to select) Tab to 'OK'.  Hit the return key     Select hot spare to bring into RAID 1 mirror set   Rebuild automatically commences     Rebuild in process   Restart now or restart after rebuild is completed

    Read the article

  • How best to keep bumbling, non-technical managers at bay and still deliver good work?

    - by Curious
    This question may be considered subjective (I got a warning) and be closed, but I will risk it, as I need some good advice/experience on this. I read the following at the 'About' page of Fog Creek Software, the company that Joel Spolsky founded and is CEO of: Back in the year 2000, the founders of Fog Creek, Joel Spolsky and Michael Pryor, were having trouble finding a place to work where programmers had decent working conditions and got an opportunity to do great work, without bumbling, non-technical managers getting in the way. Every high tech company claimed they wanted great programmers, but they wouldn’t put their money where their mouth was. It started with the physical environment (with dozens of cubicles jammed into a noisy, dark room, where the salespeople shouting on the phone make it impossible for developers to concentrate). But it went much deeper than that. Managers, terrified of change, treated any new idea as a bizarre virus to be quarantined. Napoleon-complex junior managers insisted that things be done exactly their way or you’re fired. Corporate Furniture Police writhed in agony when anyone taped up a movie poster in their cubicle. Disorganization was so rampant that even if the ideas were good, it would have been impossible to make a product out of them. Inexperienced managers practiced hit-and-run management, issuing stern orders on exactly how to do things without sticking around to see the farcical results of their fiats. And worst of all, the MBA-types in charge thought that coding was a support function, basically a fancy form of typing. A blunt truth about most of today's big software companies! Unfortunately not every developer is as gutsy (or lucky, may I say?) as Joel Spolsky! So my question is: How best to work with such managers, keep them at bay and still deliver great work?

    Read the article

  • why is there so much variance in prices for a 2-bay NAS?

    - by jcollum
    I'm considering buying a 2bay NAS for media storage. I'm perplexed by the variety of prices. They go from about $115 to $1200. The only thing I could see that differentiated the high end drive was encryption and a dual gigabit ethernet port. I don't understand how that can add up to $800+ dollars. Clearly I should know why there's this price variance before considering buying a 2 Bay NAS. Newegg link to 2 Bay NAS Should I move this question to serverfault?

    Read the article

  • Gateway laptop module bay light repeating 12 flashes - what error is that?

    - by Simurr
    I have a Gateway M465-E laptop currently running fine with a T2300E Core Duo installed. I wanted to upgrade it to a Core 2 Duo. My brother has the same model laptop and that took a Core 2 Duo (T7200) just fine. Picked up a T7200 on ebay and installed it. Normally when booting all the indicator lights flash once and the fan spins up before the machine actually starts to POST. With the T7200 installed all the lights flash and the fan spins up, but the module bay activity light flashes 12 times repeatedly. I'm assuming this is an error code, but can find no information about it. There are no beep codes. I've removed the ram, HD, Bay module and no change. Switched back to the T2300E and everything works fine. Anyone know what that error code is? The motherboard was actually manufactured by Foxconn if that helps. Update 1 Returned the CPU as defective. I tested it in 3 M465-E's and all of them did exactly the same thing. I still have no idea what the error code is. I'd still like to know for future reference. Perhaps I should try removing the CPU from one of them and see what happens.

    Read the article

  • Proliant server will not accept new hard disks in RAID 1+0?

    - by Leigh
    I have a HP ProLiant DL380 G5, I have two logical drives configured with RAID. I have one logical drive RAID 1+0 with two 72 gb 10k sas 1 port spare no 376597-001. I had one hard disk fail and ordered a replacement. The configuration utility showed error and would not rebuild the RAID. I presumed a hard disk fault and ordered a replacement again. In the mean time I put the original failed disk back in the server and this started rebuilding. Currently shows ok status however in the log I can see hardware errors. The new disk has come and I again have the same problem of not accepting the hard disk. I have updated the P400 controller with the latest firmware 7.24 , but still no luck. The only difference I can see is the original drive has firmware 0103 (same as the RAID drive) and the new one has HPD2. Any advice would be appreciated. Thanks in advance Logs from server ctrl all show config Smart Array P400 in Slot 1 (sn: PAFGK0P9VWO0UQ) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 1, Interim Recovery Mode) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 73.5 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, Failed array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK) ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAFGK0P9VWO0UQ Cache Serial Number: PA82C0J9VWL8I7 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: E Firmware Version: 7.24 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Status Details: A cache error was detected. Run more information. Cache Ratio: 100% Read / 0% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: Failed Physical Drive Array Type: Data One of the drives on this array have failed or has Logical Drive: 1 Size: 68.5 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17594 Strip Size: 128 KB Full Stripe Size: 128 KB Status: Interim Recovery Mode Caching: Enabled Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive0 Mount Points: C:\ 68.5 GB Logical Drive Label: A0100539PAFGK0P9VWO0UQ0E93 Mirror Group 0: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, S Mirror Group 1: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, S Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 73.5 GB Rotational Speed: 10000 Firmware Revision: 0103 Serial Number: B379P8C006RK Model: HP DG072A9B7 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: Failed Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: D5A1PCA04SL01244 Model: HP EH0072FARUA PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data Logical Drive: 2 Size: 558.7 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Co Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive1 Mount Points: E:\ 558.7 GB Logical Drive Label: AF14FD12PAFGK0P9VWO0UQD007 Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE07QH300009923X1X3 Model: HP DG0300BALVP Current Temperature (C): 32 Maximum Temperature (C): 45 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE0AHVH00009924P8F3 Model: HP DG0300BALVP Current Temperature (C): 34 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE08NAK00009924KWD6 Model: HP DG0300BALVP Current Temperature (C): 35 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown

    Read the article

  • is it possible to get a programming job in the bay area?

    - by user475119
    Is it my perception or is it reality that it is harder to get software development work in Silicon Valley, than in other population centers? My theory is that some of the best and brightest (and youngest) are all here. All working for the top tech companies. And, little ol' me, over 40, math degree (not at Standford or Berkeley), ok at algorithms, and with many skills with many programming tools and concepts, but not published, and not top my class has a bit of a tough time competing. (I'm a Python programmer, by the way.) Thanks

    Read the article

  • Putting two physical hard drives in a single 2.5" bay?

    - by dgw
    My crazy brain came up with this ridiculous idea. "Why can't I have a single 2.5" drive device that actually contains two independent hard drives? I want RAID 1 data mirroring and the security of having redundant drives. This is a thing that must exist!" To be clear, I am not asking if I can somehow shoehorn two 2.5" drives into a single bay, replace an optical drive with an additional HDD, or anything like that. What I have in mind is a single 2.5"-form-factor device that houses two independent hard drives, with separate housings (likely) and distinct controllers. Probably all they'd need to share is the power & SATA connections. Probably no such thing exists, but because I know there exist hard drives the physical size of a stack of postage stamps (roughly), I have to ask.

    Read the article

  • Systems Solutions at COLLABORATE12

    - by ferhat
    Want to connect with fellow Oracle users and learn more about how to maximize your Oracle software environments with Oracle Systems?   Pack your bags for Las Vegas!   COLLABORATE 12  is right around the corner! COLLABORATE 12 Conference will be held at the Mandalay Bay in Las Vegas, NV 22-26 April, 2012. This is an event designed and delivered by users just like you with sessions, interactive panel discussions and hands-on learning opportunities packed with first-hand experiences, case studies and practical “how-to” content.. This year’s event includes a number of educational sessions and demos for users interested in learning from the experts how to use Oracle Optimized Solutions to get the most out of their Oracle Technology and Application software. Oracle Optimized Solutions are proven blueprints that eliminate integration guesswork by combing best in class hardware and software components to deliver complete system architectures that are fully tested, and include documented best practices that reduce integration risks and deliver better application performance.  And because they are highly flexible by design,  Oracle Optimized Solutions   can be implemented as an end-to-end solution or easily adapted into existing environments. Follow Oracle Infrared at Twitter, Facebook, Google+, and LinkedIn  to catch the latest news, developments, announcements, and inside views from  Oracle Optimized Solutions. Please come by our Exhibition Booth #1273 to see the demos and meet 1-1 with the experts behind a number of  Oracle Optimized Solutions  including those for JD Edwards EnterpriseOne, E-Business Suite, PeopleSoft HCM, Oracle WebCenter, and Oracle Database.  Exhibitor Showcase Booth #1273 DAY TIME TITLE Monday  April 23 6:00 pm - 8:00 pm Welcome Reception in the Exhibitor Showcase Tuesday  April 24 10:15 am - 4:00 pm Exhibitor Showcase Open 1:00 pm - 2:00 pm Dedicated Exhibitor Showcase Time 5:30 pm - 7:00 pm Exhibitor Showcase Happy Hour Wednesday  April 25 10:30 am - 3:00 pm Exhibitor Showcase Open 2:15 pm -3:00 pm Afternoon Break in Exhibitor Showcase  There are also a number of deep dive, educational sessions covering deployment best practices using Oracle’s engineered systems and best-in-class hardware, operating system and virtualization technologies.  Education Sessions DAY TIME TITLE LOCATION Monday  April 23 9:45 am - 10:45 am Architecting and Implementing Backup and Recovery Solutions Surf E Tuesday  April 24 2:00 pm – 3:00 pm Oracle's High Performance Systems for JD Edwards EnterpriseOne Mandalay Bay GH 4:30 pm - 5:30 pm Virtualization Boot Camp: What's New with Oracle VM Server for x86 Mandalay Bay C 9:30 am - 10:30 am Oracle on Oracle VM - Expert Panel Mandalay Bay L Wednesday  April 25 9:30 am - 10:30 am Cloud Computing Directions: Part II Understanding Oracle's Cloud Directions South Seas E  And don’t forget the keynotes and software roadmap sessions! Keynotes and Roadmap Sessions DAY TIME TITLE LOCATION Sunday  April 22 3:20 pm – 4:20 pm Oracle’s Cloud Computing Strategy Breakers B Monday  April 23 11:00 am – 12:00 pm JD Edwards - Vision, Promises and Execution: IT'S THE WAY WE ROLL and Why it Matters! Mandalay Bay A 11:00 am – 12:00 pm PeopleSoft Executive Update and Roadmap Mandalay Bay J 1:15 pm - 2:15 pm Oracle Database - Engineered for Innovation Mandalay Bay L 2:30 pm - 3:30 pm Oracle E-Business Suite Applications Strategy and General Manager Update Mandalay Bay D Tuesday  April 24 9:15 am - 10:15 am IT at Oracle: The Art of IT Transformation to Enable Business Growth Mandalay Bay Ballroom H

    Read the article

  • LEFT OUTER JOIN SUM doubles problem

    - by Michael
    Hi I've got two tables: Table: Shopping shop_id shop_name shop_time 1 Brian 40 2 Brian 31 3 Tom 20 4 Brian 30 Table:bananas banana_id banana_amount banana_person 1 1 Brian 2 1 Brian I now want it to print: Name: Tom | Time: 20 | Bananas: 0 Name: Brian | Time: 101 | Bananas: 2 I used this code: $result = dbquery("SELECT tz.*, tt.*, SUM(shop_time) as shoptime, count(banana_amount) as bananas FROM shopping tt LEFT OUTER JOIN bananas tz ON tt.shop_name=tz.banana_person GROUP by banana_person LIMIT 40 "); while ($data5 = dbarray($result)) { echo 'Name: '.$data5["shop_name"].' | Time: '.$data5["shoptime"].' | Bananas: '.$data5["bananas"].'<br>'; } The problem is that I get this instead: Name: Tom | Time: 20 | Bananas: 0 Name: Brian | Time: 202 | Bananas: 6 I just don't know how to get around this.

    Read the article

  • In Java Concurrency In Practice by Brian Goetz, why is the Memoizer class not annotated with @ThreadSafe?

    - by dig_dug
    Java Concurrency In Practice by Brian Goetz provides an example of a efficient scalable cache for concurrent use. The final version of the example showing the implementation for class Memoizer (pg 108) shows such a cache. I am wondering why the class is not annotated with @ThreadSafe? The client, class Factorizer, of the cache is properly annotated with @ThreadSafe. The appendix states that if a class is not annotated with either @ThreadSafe or @Immutable that it should be assumed that it isn't thread safe. Memoizer seems thread-safe though. Here is the code for Memoizer: public class Memoizer<A, V> implements Computable<A, V> { private final ConcurrentMap<A, Future<V>> cache = new ConcurrentHashMap<A, Future<V>>(); private final Computable<A, V> c; public Memoizer(Computable<A, V> c) { this.c = c; } public V compute(final A arg) throws InterruptedException { while (true) { Future<V> f = cache.get(arg); if (f == null) { Callable<V> eval = new Callable<V>() { public V call() throws InterruptedException { return c.compute(arg); } }; FutureTask<V> ft = new FutureTask<V>(eval); f = cache.putIfAbsent(arg, ft); if (f == null) { f = ft; ft.run(); } } try { return f.get(); } catch (CancellationException e) { cache.remove(arg, f); } catch (ExecutionException e) { throw launderThrowable(e.getCause()); } } } }

    Read the article

  • Cannot log in with created user in mysql

    - by Brian G
    Using this command GRANT ALL PRIVILEGES ON *.* to brian@'%' identified by 'password'; I try to login with: mysql -u brian -ppassword The error is: ERROR 1045 (28000): Access denied for user 'brian'@'localhost' (using password: YES) I am doing this as root and I did try to flush privileges. I tried this with countless users but it does not seem to work. I can create a user with no password and login works. Command line and from phpmyadmin

    Read the article

  • Adding third disk as a single disk in a server with an existing RAID1

    - by slowhandsolo
    I've got a ProLiant DL360 G5 server (Fedora 13) with two SAS disks in a hardware RAID 1, working fine. Now I hot plugged another SAS disk. I'd like to configure this new hard disk out of my RAID, as a single non-RAID disk (ex. /dev/sdb). Even after rebooting the server, I can't see the new disk with "fdisk -l". It displays only my hardware RAID, but not the new disk. [root@myserver]# fdisk -l Disco /dev/cciss/c0d0: 300.0 GB, 299966445568 bytes Disposit. Inicio Comienzo Fin Bloques Id Sistema /dev/cciss/c0d0p1 * 1 126 512000 83 Linux /dev/cciss/c0d0p2 126 71798 292422656 8e Linux LVM Disco /dev/dm-0: 234.9 GB, 234881024000 bytes Disco /dev/dm-1: 10.5 GB, 10536091648 bytes Disco /dev/dm-2: 21.0 GB, 20971520000 bytes Disco /dev/dm-3: 31.5 GB, 31474057216 bytes Disco /dev/dm-4: 1577 MB, 1577058304 bytes However, I can see the new disk using the HP Array Configuration Utility CLI for Linux "hpacucli": [root@myserver]# hpacucli => controller slot=0 physicaldrive all show status physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 300 GB): OK physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 300 GB): OK physicaldrive 1I:1:3 (port 1I:box 1:bay 3, 300 GB): OK => controller slot=0 pd all show detail Smart Array P400i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 **unassigned** physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: **Unassigned Drive** As you can see, I've got two SAS disks in a RAID 1 and the new disk as "unassigned". Is there any way to work with the new disk as another non-RAID single disk? If relevant, I want to create a new partition in my new disk, format it with mkfs and mount it, but as I can't see it with fdisk, I don't know how to do it. Thanks!

    Read the article

  • moving raid 10 to another identical server both on Smart Array 6i controllers

    - by SalimQrdl
    I have dead HP DL 380G4 with RAID 1+0 with 1 logical volume from 4x72GB drives on built-in Smart Array 6i 128Mb BBWC. It was shut down properly. It seems it was usual death for Proliant with ILO led 2,3,8 lighting. I want to move array to another identical server with same raid firmware level. What is the best strategy?: I have RAID 1+0 on bay 0 bay 1 bay 2 bay 3 As I understand bay0+bay1 are in RAID 1 , bay2+bay3 are in RAID 1, and both RAID 1 pairs are in RAID 0. So should I : Clear RAID config on new server, insert bay 0, bay 2 and power-on or Create RAID 1+0 with 1 logical volume from clear HDDs , and then poweroff ,remove HDDs and insert 2 HDDs(bay 0, bay 2) from old RAID 1+0. then power-on. (each hdd has its raid position info stored but may be could work on same config) According to documentation for Smart Array 6i it could be possible to migrate. however one requirement point is unclear for me Before you move drives, the following conditions must be met: • The array is in its original configuration. " What is orginal and non-original config for RAID 1+0? Another point "If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time." I want to move one hdd from each RAID 1 pair. to have mirrors untouched just in case. Do they mean to move all 4 simultaniously? Smart Array 6i User Guide: Moving Drives and Arrays You can move drives to other ID positionson the same array controller. You can also move a complete arrayfrom one controller to another, even if the controllers are on different servers. Before you move drives, the following conditions must be met: • If moving thedrives to a different server, the new server must have enough empty bays to accommodate all the drives simultaneously. • The move will not result in more than 14 physical drives per controller channel. • No controller will be configured with more than 32 logical volumes. • The array has no failed or missing drives. • The array is in its original configuration. • The controller is not reading from or writing to any of the spare drives in the array. • The controller is not running capacity expansion, capacity extension, or RAID or stripe size migration. • The controller is using the latestfirmware version (recommended). If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time. • In most cases, a moved array (and the logical drives that it contains) can still undergo arraycapacity expansion, logical drive capacity extension, or migration of RAID level orstripe size. When all the conditions have been met: Back up all data before removing any drives or changing configuration. This step is requiredif you are moving data-containing drives from a controller that does not have a battery-backed cache. Power down the system. If you are moving an array from a controller that contains a RAID ADG logical volume to a controller that does not support RAID ADG: Move the drives. Power up the system. If a 1724 POST message is displayed, drive positions were changed successfully and the configuration was updated. If a 1785 (NotConfigured)POST message is displayed: a. Power down the system immediately to prevent data loss. b. Return the drives to their original locations. c. Restore the data from backup, if necessary. Check the new drive configuration byrunning ORCA or ACU ("Configuring an Array" on page 9).

    Read the article

  • Top 31 Favorite Features in Windows Server 2012

    - by KeithMayer
    Over the past month, my fellow IT Pro Technical Evangelists and I have authored a series of articles about our Top 31 Favorite Features in Windows Server 2012.  Now that our series is complete, I’m providing a clickable index below of all of the articles in the series for your convenience, just in case you perhaps missed any of them when they were first released.  Hope you enjoy our Favorite Features in Windows Server 2012! Top 31 Favorite Features in Windows Server 2012 The Cloud OS Platform by Kevin Remde Server Manager in Windows Server 2012 by Brian Lewis Feel the Power of PowerShell 3.0 by Matt Hester Live Migrate Your VMS in One Line of PowerShell by Keith Mayer Windows Server 2012 and Hyper-V Replica by Kevin Remde Right-size IT Budgets with “Storage Spaces” by Keith Mayer Yes, there is an “I” in Team – the NIC Team! by Kevin Remde Hyper-V Network Virtualization by Keith Mayer Get Happy over the FREE Hyper-V Server 2012 by Matt Hester Simplified BranchCache in Windows Server 2012 by Brian Lewis Getting Snippy with PowerShell 3.0 by Matt Hester How to Get Unbelievable Data Deduplication Results by Chris Henley of Veeam Simplified VDI Configuration and Management by Brian Lewis Taming the New Task Manager by Keith Mayer Improve File Server Resiliency with ReFS by Keith Mayer Simplified DirectAccess by Sumeeth Evans SMB 3.0 – The Glue in Windows Server 2012 by Matt Hester Continuously Available File Shares by Steven Murawski of Edgenet Server Core - Improved Taste, Less Filling, More Uptime by Keith Mayer Extend Your Hyper-V Virtual Switch by Kevin Remde To NIC or to Not NIC Hardware Requirements by Brian Lewis Simplified Licensing and Server Versions by Kevin Remde I Think, Therefore IPAM! by Kevin Remde Windows Server 2012 and the RSATs by Kevin Remde Top 3 New Tricks in the Active Directory Admin Center by Keith Mayer Dynamic Access Control by Brian Lewis Get the Gremlin out of Your Active Directory Virtualized Infrastructure by Matt Hester Scoping out the New DHCP Failover by Keith Mayer Gone in 8 Seconds – The New CHKDSK by Matt Hester New Remote Desktop Services (RDS) by Brian Lewis No Better Time Than Now to Choose Hyper-V by Matt Hester What’s Next? Keep Learning! Want to learn more about Windows Server 2012 and Hyper-V Server 2012?  Want to prepare for certification on Windows Server 2012? Do It: Join our Windows Server 2012 “Early Experts” Challenge online peer study group for FREE at http://earlyexperts.net. You’ll get FREE access to video-based lectures, structured study materials and hands-on lab activities to help you study and prepare!  Along the way, you’ll be part of an IT Pro community of over 1,000+ IT Pros that are all helping each other learn Windows Server 2012! What are Your Favorite Features? Do you have a Favorite Feature in Windows Server 2012 that we missed in our list above?  Feel free to share your favorites in the comments below! Keith Build Your Lab! Download Windows Server 2012 Don’t Have a Lab? Build Your Lab in the Cloud with Windows Azure Virtual Machines Want to Get Certified? Join our Windows Server 2012 "Early Experts" Study Group

    Read the article

  • One National Team One Event &ndash; SharePoint Saturday Kansas City

    - by MOSSLover
    I wasn’t expect to run an event from 1,000 miles away, but some stuff happened you know like it does and I opted in.  It was really weird, because people asked why are you living in NJ and running Kansas City?  I did move, but it was like my baby and Karthik didn’t have the ability to do it this year.  I found it really challenging, because I could not physically be in Kansas City.  At first I was freaking out and Lee Brandt, Brian Laird, and Chris Geier offered to help.  Somehow I couldn’t come the day of the event.  Time-wise it just didn’t work out.  I could do all the leg work prior to the event, but weekends just were not good.  I was going to be in DC until March or April on the weekdays, so leaving that weekend was too tough.  As it worked out Lee was my eyes and ears for the venue.  Brian was the sponsor and prize box coordinator if anyone needed to send items.  Lee also helped Brian the day of the event move all the boxes.  I did everything we could do electronically, such as get the sponsors coordinate with Michael Lotter on invoicing and getting the speakers, posting the submissions, budgeting the money, setting up a speaker dinner by phone, plus all that other stuff you do behind the scenes.  Chris was there to help Lee and Brian the day of the event and help us out with the speaker dinner.  Karthik finally got back from India and he was there the night before getting the folders together and the signs and stuffing it all.  Jason Gallicchio also helped me out (my cohort for SPS NYC) as he did the schedule and helped with posting the speakers abstracts and so did Chris Geier by posting the bios.  The lot of them enlisted a few other monkeys to help out.  It was the weirdest thing I’ve ever seen, but it worked.  Around 100+ attendees ended up showing and I hear it was  a great event.  Jason, Michael, Chris, Karthik, Brian, and Lee are not all from the same area, but they helped me out in bringing this event together.  It was a national SharePoint Saturday team that brought together a specific local event for Kansas City.  It’s like a metaphor for the entire SharePoint Community.  We help our own kind out we don’t let me fail.  I know Lee and Brian aren’t technically SharePoint People they are honorary SharePoint Community Members.  Thanks everyone for the support and help in bringing this event together.  Technorati Tags: SharePoint Saturday,SPS KC,SharePoint,SharePoint Saturday Kanas City,Kansas City

    Read the article

  • Can't Remove Logical Drive/Array from HP P400

    - by Myles
    This is my first post here. Thank you in advance for any assistance with this matter. I'm trying to remove a logical drive (logical drive 2) and an array (array "B") from my Smart Array P400. The host is a DL580 G5 running 64-bit Red Hat Enterprise Linux Server release 5.7 (Tikanga). I am unable to remove the array using either hpacucli or cpqacuxe. I believe it is because of "OS Status: LOCKED". The file system that lives on this array has been unmounted. I do not want to reboot the host. Is there some way to "release" this logical drive so I can remove the array? Note that I do not need to preserve the data on logical drive 2. I intend to physically remove the drives from the machine and replace them with larger drives. I'm using the cciss kernel module that ships with Red Hat 5.7. Here is some information pertaining to the host and the P400 configuration: [root@gort ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.7 (Tikanga) [root@gort ~]# uname -a Linux gort 2.6.18-274.el5 #1 SMP Fri Jul 8 17:36:59 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux [root@gort ~]# rpm -qa | egrep '^(hp|cpq)' cpqacuxe-9.30-15.0 hp-health-9.25-1551.7.rhel5 hpsmh-7.1.2-3 hpdiags-9.3.0-466 hponcfg-3.1.0-0 hp-snmp-agents-9.25-2384.8.rhel5 hpacucli-9.30-15.0 [root@gort ~]# hpacucli HP Array Configuration Utility CLI 9.30.15.0 Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. => ctrl all show config detail Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Cache Serial Number: PA82C0J9SVW34U RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: D Firmware Version: 7.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 128 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Unique Identifier: 600508B100184A395356573334550002 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 101 MB, /tmp 7.8 GB, /usr 3.9 GB, /usr/local 2.0 GB, /var 3.9 GB, / 2.0 GB, /local 113.2 GB OS Status: LOCKED Logical Drive Label: A0027AA78DEE Mirror Group 0: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) Drive Type: Data Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM57RF40000983878FX Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 35 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM55VQC000098388524 Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 36 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Logical Drive: 2 Size: 546.8 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 256 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Completed Unique Identifier: 600508B100184A395356573334550003 Disk Name: /dev/cciss/c0d1 Mount Points: None OS Status: LOCKED Logical Drive Label: A5C9C6F81504 Drive Type: Data Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2H5PE00009802NK19 Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 37 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 1I:1:4 Port: 1I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM28YY400009750MKPJ Model: HP DG146ABAB4 Current Temperature (C): 31 Maximum Temperature (C): 36 PHY Count: 1 PHY Transfer Rate: 3.0Gbps physicaldrive 2I:1:5 Port: 2I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FGYV00009802N3GN Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 38 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 2I:1:6 Port: 2I Box: 1 Bay: 6 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM8AFAK00009920MMV1 Model: HP DG146BB976 Current Temperature (C): 31 Maximum Temperature (C): 41 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:7 Port: 2I Box: 1 Bay: 7 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FJQD00009801MSHQ Model: HP DG146ABAB4 Current Temperature (C): 29 Maximum Temperature (C): 39 PHY Count: 1 PHY Transfer Rate: Unknown

    Read the article

  • Getting null value after adding objects to customClass

    - by Brian Stacks
    Ok here's my code first viewController.h @interface ViewController : UIViewController<UICollectionViewDataSource,UICollectionViewDelegate> { NSMutableArray *twitterObjects; } @property (strong, nonatomic) IBOutlet UICollectionView *myCollectionView; Here is my viewController.m // // ViewController.m // MDF2p2 // // Created by Brian Stacks on 6/5/14. // Copyright (c) 2014 Brian Stacks. All rights reserved. // #import "ViewController.h" // add accounts framework to code #import <Accounts/Accounts.h> // add social frameworks #import <Social/Social.h> #import "TwitterCustomObject.h" #import "CustomCell.h" #import "DetailViewController.h" @interface ViewController () @end @implementation ViewController -(void)prepareForSegue:(UIStoryboardSegue *)segue sender:(id)sender { //CustomCell * cell = (CustomCell*)sender; //NSIndexPath *indexPath = [_myCollectionView indexPathForCell:cell]; // setting an id for view controller DetailViewController *detailViewcontroller = segue.destinationViewController; //TwitterCustomObject *newCustomClass = [twitterObjects objectAtIndex:indexPath.row]; if (detailViewcontroller != nil) { // setting the custom customClass object //detailViewcontroller.myNewCurrentClass = newCustomClass; } } - (void)viewDidLoad { twitterObjects = [[NSMutableArray alloc]init]; [super viewDidLoad]; [self twitterAPIcall]; // Do any additional setup after loading the view, typically from a nib. } - (NSInteger)collectionView:(UICollectionView *)collectionView numberOfItemsInSection:(NSInteger)section { return 100; } - (UICollectionViewCell *)collectionView:(UICollectionView *)collectionView cellForItemAtIndexPath:(NSIndexPath *)indexPath { //UICollectionViewCell *cell = [collectionView dequeueReusableCellWithReuseIdentifier:@"myCell" forIndexPath:indexPath]; // initiate celli CustomCell * cell = [collectionView dequeueReusableCellWithReuseIdentifier:@"myCell" forIndexPath:indexPath]; // add objects to cell if (cell != nil) { //TwitterCustomObject *newCustomClass = [twitterObjects objectAtIndex:indexPath.row]; //[cell refreshCell:newCustomClass.userName userImage:newCustomClass.userImage]; [cell refreshCell:@"Brian" userImage:[UIImage imageNamed:@"love.jpg"]]; } return cell; } -(void)twitterAPIcall { //create an instance of the account store from account frameworks ACAccountStore *accountStore = [[ACAccountStore alloc]init]; // make sure we have a valid object if (accountStore != nil) { // get the account type ex: Twitter, FAcebook info ACAccountType *accountType = [accountStore accountTypeWithAccountTypeIdentifier:ACAccountTypeIdentifierTwitter]; // make sure we have a valid object if (accountType != nil) { // give access to the account iformation [accountStore requestAccessToAccountsWithType:accountType options:nil completion:^(BOOL granted, NSError *error) { if (granted) { //^^^success user gave access to account information // get the info of accounts NSArray *twitterAccounts = [accountStore accountsWithAccountType:accountType]; // make sure we have a valid object if (twitterAccounts != nil) { //NSLog(@"Accounts: %@",twitterAccounts); // get the current account information ACAccount *currentAccount = [twitterAccounts objectAtIndex:0]; // make sure we have a valid object if (currentAccount != nil) { //string from twitter api NSString *requestString = @"https://api.twitter.com/1.1/friends/list.json"; // request the data from the request screen call SLRequest *myRequest = [SLRequest requestForServiceType:SLServiceTypeTwitter requestMethod:SLRequestMethodGET URL:[NSURL URLWithString:requestString] parameters:nil]; // must authenticate request [myRequest setAccount:currentAccount]; // perform the request named myRequest [myRequest performRequestWithHandler:^(NSData *responseData, NSHTTPURLResponse *urlResponse, NSError *error) { // check to make sure there are no errors and we have a good http:request of 200 if ((error == nil) && ([urlResponse statusCode] == 200)) { // make array of dictionaries from the twitter api data using NSJSONSerialization NSArray *twitterFeed = [NSJSONSerialization JSONObjectWithData:responseData options:0 error:nil]; NSMutableArray *nameArray = [twitterFeed valueForKeyPath:@"users"]; // for loop that loops through all the post for (NSInteger i =0; i<[twitterFeed count]; i++) { NSString *nameString = [nameArray valueForKeyPath:@"name"]; NSString *imageString = [nameArray valueForKeyPath:@"profile_image_url"]; NSLog(@"Name feed: %@",nameString); NSLog(@"Image feed: %@",imageString); // get data into my mutable array TwitterCustomObject *twitterInfo = [self createPostFromArray:[nameArray objectAtIndex:i]]; //NSLog(@"Image feed: %@",twitterInfo); if (twitterInfo != nil) { [twitterObjects addObject:twitterInfo]; } } } }]; } } } else { // the user didn't give access UIAlertView *alert = [[UIAlertView alloc] initWithTitle:@"Warning" message:@"This app will only work with twitter accounts being allowed!." delegate:self cancelButtonTitle:@"OK" otherButtonTitles:nil, nil]; [alert performSelectorOnMainThread:@selector(show) withObject:nil waitUntilDone:FALSE]; } }]; } } } -(TwitterCustomObject*)createPostFromArray:(NSArray*)postArray { // create strings to catch the data in NSArray *userArray = [postArray valueForKeyPath:@"users"]; NSString *myUserName = [userArray valueForKeyPath:@"name"]; NSString *twitImageURL = [userArray valueForKeyPath:@"profile_image_url"]; UIImage *image = [UIImage imageWithData:[NSData dataWithContentsOfURL:[NSURL URLWithString:twitImageURL]]]; // initiate object to put the data in TwitterCustomObject *twitterData = [[TwitterCustomObject alloc]initWithPostInfo:myUserName myImage:image]; NSLog(@"Name: %@",myUserName); return twitterData; } -(IBAction)done:(UIStoryboardSegue*)segue { } - (void)didReceiveMemoryWarning { [super didReceiveMemoryWarning]; // Dispose of any resources that can be recreated. } @end Here is my customObject class TwitterCustomClass.h // // TwitterCustomObject.h // MDF2p2 // // Created by Brian Stacks on 6/5/14. // Copyright (c) 2014 Brian Stacks. All rights reserved. // #import <Foundation/Foundation.h> @interface TwitterCustomObject : NSObject { } @property (nonatomic, readonly) NSString *userName; @property (nonatomic, readonly) UIImage *userImage; -(id)initWithPostInfo:(NSString*)screenName myImage:(UIImage*)myImage; @end TwitterCustomClass.m // // TwitterCustomObject.m // MDF2p2 // // Created by Brian Stacks on 6/5/14. // Copyright (c) 2014 Brian Stacks. All rights reserved. // #import "TwitterCustomObject.h" @implementation TwitterCustomObject -(id)initWithPostInfo:(NSString*)screenName myImage:(UIImage*)myImage { // initialize as object if (self = [super init]) { // use the data to be passed back and forth to the tableview _userName = [screenName copy]; _userImage = [myImage copy]; } return self; } @end The problem is I get the values in the method twitterAPIcall, I can get the names and image values or strings from the values. But in the (TwitterCustomObject*)createPostFromArray:(NSArray*)postArray method all values are coming up as null.I thought it got added with this line of code in the twitterAPIcall method [twitterObjects addObject:twitterInfo];?

    Read the article

  • This is the End of Business as Usual...

    - by Michael Snow
    This week, we'll be hosting our last Social Business Thought Leader Series Webcast for 2012. Our featured guest this week will be Brian Solis of Altimeter Group. As we've been going through the preparations for Brian's webcast, it became very clear that an hour's time is barely scraping the surface of the depth of Brian's insights and analysis. Accordingly, in the spirit of sharing Brian's perspective for all of our readers, we'll be featuring guest posts all this week pulled from Brian's larger collection of blog postings on his own website. If you like what you've read here this week, we highly recommend digging deeper into his tome of wisdom. Guest Post by Brian Solis, Analyst, Altimeter Group as originally featured on his site with the minor change of the video addition at the beginning of the post. This is the End of Business as Usual and the Beginning of a New Era of Relevance - Brian Solis, Principal Analyst, Altimeter Group The Times They Are A-Changin’ Come gather ’round people Wherever you roam And admit that the waters Around you have grown And accept it that soon You’ll be drenched to the bone If your time to you Is worth savin’ Then you better start swimmin’ Or you’ll sink like a stone For the times they are a-changin’. - Bob Dylan I’m sure you are wondering why I chose lyrics to open this article. If you skimmed through them, stop here for a moment. Go back through the Dylan’s words and take your time. Carefully read, and feel, what it is he’s saying and savor the moment to connect the meaning of his words to the challenges you face today. His message is as important and true today as it was when they were first written in 1964. The tide is indeed once again turning. And even though the 60s now live in the history books, right here, right now, Dylan is telling us once again that this is our time to not only sink or swim, but to do something amazing. This is your time. This is our time. But, these times are different and what comes next is difficult to grasp. How people communicate. How people learn and share. How people make decisions. Everything is different now. Think about this…you’re reading this article because it was sent to you via email. Yet more people spend their online time in social networks than they do in email. Duh. According to Nielsen, of the total time spent online 22.5% are connecting and communicating in social networks. To put that in perspective, the time spent in the likes of Facebook, Twitter, and Youtube is greater than online gaming at 9.8%, email at 7.6% and search at 4%. Imagine for a moment if you and I were connected to one another in Facebook, which just so happens to be the largest social network in the world. How big? Well, Facebook is the size today of the entire Internet in 2004. There are over 1 billion people friending, Liking, commenting, sharing, and engaging in Facebook…that’s roughly 12% of the world’s population. Twitter has over 200 million users. Ever hear of tumblr? More time is spent on this popular microblogging community than Twitter. The point is that the landscape for communication and all that’s affected by human interaction is profoundly different than how you and I learned, shared or talked to one another yesterday. This transformation is only becoming more pervasive and, it’s not going back. Survival of the Fitting But social media is just one of the channels we can use to reach people. I must be honest. I’m as much a part of tomorrow as I am of yesteryear. It’s why I spend all of my time researching the evolution of media and its impact on business and culture. Because of you, I share everything I learn in newsletters, emails, blogs, Youtube videos, and also traditional books. I’m dedicated to helping everyone not only understand, but grasp the change that’s before you. Technologies such as social, mobile, virtual, augmented, et al compel us adapt our story and value proposition and extend our reach to be part of communities we don’t realize exist. The people who will keep you in business or running tomorrow are the very people you’re not reaching today. Before you continue to read on, allow me to clarify my point of view. My inspiration for writing this is to help you augment, not necessarily replace, the programs you’re running today. We must still reach those whom matter to us in the ways they prefer to be engaged. To reach what I call the connected consumer of Geneeration-C we must too reach them in the ways they wish to be engaged. And in all of my work, how they connect, talk to one another, influence others, and make decisions are not at all like the traditional consumers of the past. Nor are they merely the kids…the Millennial. Connected consumers are representative across every age group and demographic. As you can see, use of social networks, media sharing sites, microblogs, blogs, etc. equally span across Gen Y, Gen X, and Baby Boomers. The DNA of connected customers is indiscriminant of age or any other demographic for that matter. This is more about psychographics, the linkage of people through common interests (than it is their age, gender, education, nationality or level of income. Once someone is introduced to the marvels of connectedness, the sensation becomes a contagion. It touches and affects everyone. And, that’s why this isn’t going anywhere but normalcy. Social networking isn’t just about telling people what you’re doing. Nor is it just about generic, meaningless conversation. Today’s connected consumer is incredibly influential. They’re connected to hundreds and even thousands of other like-minded people. What they experiences, what they support, it’s shared throughout these networks and as information travels, it shapes and steers impressions, decisions, and experiences of others. For example, if we revisit the Nielsen research, we get an idea of just how big this is becoming. 75% spend heavily on music. How does that translate to the arts? I’d imagine the number is equally impressive. If 53% follow their favorite brand or organization, imagine what’s possible. Just like this email list that connects us, connections in social networks are powerful. The difference is however, that people spend more time in social networks than they do in email. Everything begins with an understanding of the “5 W’s and H.E.” – Who, What, When, Where, How, and to What Extent? The data that comes back tells you which networks are important to the people you’re trying to reach, how they connect, what they share, what they value, and how to connect with them. From there, your next steps are to create a community strategy that extends your mission, vision, and value and it align it with the interests, behavior, and values of those you wish to reach and galvanize. To help, I’ve prepared an action list for you, otherwise known as the 10 Steps Toward New Relevance: 1. Answer why you should engage in social networks and why anyone would want to engage with you 2. Observe what brings them together and define how you can add value to the conversation 3. Identify the influential voices that matter to your world, recognize what’s important to them, and find a way to start a dialogue that can foster a meaningful and mutually beneficial relationship 4. Study the best practices of not just organizations like yours, but also those who are successfully reaching the type of people you’re trying to reach – it’s benching marking against competitors and benchmarking against undefined opportunities 5. Translate all you’ve learned into a convincing presentation written to demonstrate tangible opportunity to your executive board, make the case through numbers, trends, data, insights – understanding they have no idea what’s going on out there and you are both the scout and the navigator (start with a recommended pilot so everyone can learn together) 6. Listen to what they’re saying and develop a process to learn from activity and adapt to interests and steer engagement based on insights 7. Recognize how they use social media and innovate based on what you observe to captivate their attention 8. Align your objectives with their objectives. If you’re unsure of what they’re looking for…ask 9. Invest in the development of content, engagement 10. Build a community, invest in values, spark meaningful dialogue, and offer tangible value…the kind of value they can’t get anywhere else. Take advantage of the medium and the opportunity! The reality is that we live and compete in a perpetual era of Digital Darwinism, the evolution of consumer behavior when society and technology evolve faster than our ability to adapt. This is why it’s our time to alter our course. We must connect with those who are defining the future of engagement, commerce, business, and how the arts are appreciated and supported. Even though it is the end of business as usual, it is the beginning of a new age of opportunity. The consumer revolution is already underway, and the question is: How do you better understand the role you play in this production as a connected or social consumer as well as business professional? Again, this is your time to define a new era of engagement and relevance. Originally written for The National Arts Marketing Project Connect with Brian via: Twitter | LinkedIn | Facebook | Google+ --- Note from Michael: If you really like this post above - check out Brian's TEDTalk and his thought process for preparing it in this post: 12.00 Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-family:"Calibri","sans-serif"; mso-bidi-font-family:"Times New Roman";} http://www.briansolis.com/2012/10/tedtalk-reinventing-consumer-capitalism-screw-business-as-usual/

    Read the article

  • vSphere Client vCenter Template Customization Specification Using Windows Sysprep Unattended Answer XML File

    - by Brian
    I'm trying to setup a vSphere Client vCenter v5.0.0 Build 455964 Template Customization Specification using a Windows Sysprep unattended answer XML file for Win2008R2. However I didn't know how Sysprep worked before attempting this so it was a time-consuming nightmare (even after reviewing VMware vSphere ESXi 5's documentation)! I think I've figure out what I'm supposed to be doing, but it's still not working. The biggest problem at this point is that vSphere Client vCenter Customization Specification IP address information is not sticking when I load a Sysprep XML file with just 1 basic setting! This can only be a bug. Here is the process I'm using: PROCESS for Windows - vSphere Client Install Windows OS install VM Tools customize Windows (GPOs can be used to do this after deployment) install Applications (GPOs can be used to do this after deployment too) shutdown the VM convert the VM to a template create a custom Windows Sysprep XML answer file with desired customizations View Management Customization Specifications Manager create "New" Specification for "Target Virtual Machine OS" select Windows check "Use Custom Sysprep Answer File" (ADDS: Custom Sysprep File. KEEPS: Network (IP), Operating System Options (SID, Sysprep /generalize). REPLACES: Registration Information of Owner Name & Organization, Computer Name, Windows License (Key), Administrator Password, Time Zone, Run Once, Workgroup or Domain) name it as "VMwareCS-OS####R#x32/64w/Sysprep-TEST" (CS=Customization Specification) set Description as "Created YYYY/MM/DD by FLast" NEXT import a Sysprep answer file from secure location NEXT Custom settings NEXT click "..." box to right of "Use DHCP" set "Use the following IP settings:" for "IP Address" fill out the first 2 octets set appropriate values for other 2-3 fields set DNS server addresses OK NEXT check "Generate New Security ID (SID)" ALWAYS as template is likely a domain-member computer so it can be updated occasionally NEXT Finish View Inventory VMs and Templates right-click previously completed template Deploy Virtual Machine from this Template provide the new OS name (max15char) select inventory location NEXT select Host/Cluster (wait for validation to succeed) NEXT select Resource Pool (wait for validation to succeed) NEXT select Storage location NEXT check "Power on this virtual machine after creation" select "Customize using an existing customization specification" select desired specification select "Use the Customization Wizard to temporarily adjust the specification before deployment" NEXT NEXT Custom settings? NEXT check "Generate New Security ID (SID)" ALWAYS as template is likely a domain-member computer so it can be updated occasionally NEXT Finish Finish. I know a community member named "brian" (http://serverfault.com/users/25904/brian) has worked with this scenario before, but I couldn't figure out how to contact him directly, so Brian if you see this message could you provide some information to help? Thanks, Brian

    Read the article

  • how to initialize two logical drives on a HP P400i controller without reboot

    - by John
    What I am trying to do is initialize two logical drives on a HP P400i embedded controller without a reboot of the system here my current Array config: array A (SAS, Unused Space: 0 MB) logicaldrive 1 (17.9 GB, RAID 5, OK) logicaldrive 2 (17.9 GB, RAID 5, OK) logicaldrive 3 (75.9 GB, RAID 5, OK) logicaldrive 4 (25.0 GB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 5 (99 MB, RAID 0, OK) logicaldrive 6 (68.2 GB, RAID 0, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK) windows 2003 machine running the HpCISs2.sys driver version 6.20.0.32 . I have the ACU and ACU CLI tools installed version 8.28.13.0, P400i firmware version 2.74 . Now what I'd like to do is removes the physical drive 1I:1:4 and delete the two logical drives in array B. then insert a new drive in to bay 4 that contains two new logical drives and have them show up in array B again. So far after I remove the drive and delete the failed logical drives, I insert the new drive and run HPacucli rescan. I get the new drive to show up as unassinged physical drive but I cant figure out now to "for lack of a better word" mount the 2 logical drives on the new unassinged disk. If I reboot the system the array controller picks up the new fourth drive and creates Array B with the drives without problem but I'd really like to not have to reboot the server. Any ideas?

    Read the article

  • Counting and joining two tables

    - by Eikern
    Eventhosts – containing the three regular hosts and an "other" field (if someone is replacing them) eventid | host (SET[Steve,Tim,Brian,other]) ------------------------------------------- 1 | Steve 2 | Tim 3 | Brian 4 | other 5 | other Event id | other | name etc. ---------------------- 1 | | … 2 | | … 3 | | … 4 | Billy | … 5 | Irwin | … This query: SELECT h.host, COUNT(*) AS hostcount FROM host AS h LEFT OUTER JOIN event AS e ON h.eventid = e.id GROUP BY h.host Returns Steve | 1 Tim | 1 Brian | 1 other | 2 I want it to return Steve | 1 Tim | 1 Brian | 1 Billy | 1 Irwin | 1 OR Steve | | 1 Tim | | 1 Brian | | 1 other | Billy | 1 other | Irwin | 1 Can someone tell me how I can achieve this or point me in a direction?

    Read the article