Can't Remove Logical Drive/Array from HP P400
Posted
by
Myles
on Server Fault
See other posts from Server Fault
or by Myles
Published on 2012-11-12T20:29:27Z
Indexed on
2012/11/13
5:03 UTC
Read the original article
Hit count: 580
This is my first post here. Thank you in advance for any assistance with this matter.
I'm trying to remove a logical drive (logical drive 2) and an array (array "B") from my Smart Array P400. The host is a DL580 G5 running 64-bit Red Hat Enterprise Linux Server release 5.7 (Tikanga). I am unable to remove the array using either hpacucli or cpqacuxe. I believe it is because of "OS Status: LOCKED". The file system that lives on this array has been unmounted. I do not want to reboot the host. Is there some way to "release" this logical drive so I can remove the array? Note that I do not need to preserve the data on logical drive 2. I intend to physically remove the drives from the machine and replace them with larger drives.
I'm using the cciss kernel module that ships with Red Hat 5.7.
Here is some information pertaining to the host and the P400 configuration:
[root@gort ~]# cat /etc/redhat-release
Red Hat Enterprise Linux Server release 5.7 (Tikanga)
[root@gort ~]# uname -a
Linux gort 2.6.18-274.el5 #1 SMP Fri Jul 8 17:36:59 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux
[root@gort ~]# rpm -qa | egrep '^(hp|cpq)'
cpqacuxe-9.30-15.0
hp-health-9.25-1551.7.rhel5
hpsmh-7.1.2-3
hpdiags-9.3.0-466
hponcfg-3.1.0-0
hp-snmp-agents-9.25-2384.8.rhel5
hpacucli-9.30-15.0
[root@gort ~]# hpacucli
HP Array Configuration Utility CLI 9.30.15.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.
=> ctrl all show config detail
Smart Array P400 in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Cache Serial Number: PA82C0J9SVW34U
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: D
Firmware Version: 7.22
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Surface Scan Mode: Idle
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 256 MB
Total Cache Memory Available: 208 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Logical Drive: 1
Size: 136.7 GB
Fault Tolerance: RAID 1
Heads: 255
Sectors Per Track: 32
Cylinders: 35132
Strip Size: 128 KB
Full Stripe Size: 128 KB
Status: OK
Caching: Enabled
Unique Identifier: 600508B100184A395356573334550002
Disk Name: /dev/cciss/c0d0
Mount Points: /boot 101 MB, /tmp 7.8 GB, /usr 3.9 GB, /usr/local 2.0 GB, /var 3.9 GB, / 2.0 GB, /local 113.2 GB
OS Status: LOCKED
Logical Drive Label: A0027AA78DEE
Mirror Group 0:
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK)
Mirror Group 1:
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK)
Drive Type: Data
Array: A
Interface Type: SAS
Unused Space: 0 MB
Status: OK
Array Type: Data
physicaldrive 1I:1:1
Port: 1I
Box: 1
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPDE
Serial Number: 3NM57RF40000983878FX
Model: HP DG146BB976
Current Temperature (C): 29
Maximum Temperature (C): 35
PHY Count: 2
PHY Transfer Rate: Unknown, Unknown
physicaldrive 1I:1:2
Port: 1I
Box: 1
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPDE
Serial Number: 3NM55VQC000098388524
Model: HP DG146BB976
Current Temperature (C): 29
Maximum Temperature (C): 36
PHY Count: 2
PHY Transfer Rate: Unknown, Unknown
Logical Drive: 2
Size: 546.8 GB
Fault Tolerance: RAID 5
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 64 KB
Full Stripe Size: 256 KB
Status: OK
Caching: Enabled
Parity Initialization Status: Initialization Completed
Unique Identifier: 600508B100184A395356573334550003
Disk Name: /dev/cciss/c0d1
Mount Points: None
OS Status: LOCKED
Logical Drive Label: A5C9C6F81504
Drive Type: Data
Array: B
Interface Type: SAS
Unused Space: 0 MB
Status: OK
Array Type: Data
physicaldrive 1I:1:3
Port: 1I
Box: 1
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPDE
Serial Number: 3NM2H5PE00009802NK19
Model: HP DG146ABAB4
Current Temperature (C): 30
Maximum Temperature (C): 37
PHY Count: 1
PHY Transfer Rate: Unknown
physicaldrive 1I:1:4
Port: 1I
Box: 1
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPDE
Serial Number: 3NM28YY400009750MKPJ
Model: HP DG146ABAB4
Current Temperature (C): 31
Maximum Temperature (C): 36
PHY Count: 1
PHY Transfer Rate: 3.0Gbps
physicaldrive 2I:1:5
Port: 2I
Box: 1
Bay: 5
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPDE
Serial Number: 3NM2FGYV00009802N3GN
Model: HP DG146ABAB4
Current Temperature (C): 30
Maximum Temperature (C): 38
PHY Count: 1
PHY Transfer Rate: Unknown
physicaldrive 2I:1:6
Port: 2I
Box: 1
Bay: 6
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPDE
Serial Number: 3NM8AFAK00009920MMV1
Model: HP DG146BB976
Current Temperature (C): 31
Maximum Temperature (C): 41
PHY Count: 2
PHY Transfer Rate: Unknown, Unknown
physicaldrive 2I:1:7
Port: 2I
Box: 1
Bay: 7
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPDE
Serial Number: 3NM2FJQD00009801MSHQ
Model: HP DG146ABAB4
Current Temperature (C): 29
Maximum Temperature (C): 39
PHY Count: 1
PHY Transfer Rate: Unknown
© Server Fault or respective owner