  • Using 2-port LSI 2308-8e card to control 24 SAS HDDs

    - by GregC
    I would like to rely on a RAID-on-chip solution to control 24 SAS hard drives in a direct-attached environment. How would you approach this to get best bandwidth given that I'd like to spend less than $10,000 on the interconnect. I've read that LSI 2308 chip can easily handle 8-drive SSD RAID6 in hardware. I'd like to harness its power to control 24 SAS hard drives over an expander in an external enclosure. Currently I use an Infortrend S24S-G2240 external enclosure. It provides its own controller and expander. I'd like to use LSI 2308 controller for RAID6 somehow instead of the mystery controller in the enclosure. P.S. I tried to create SAS-expander as a tag, but my rep on this site is low.

    Read the article

  • can't access SATA card config screen on boot, nor access the disks

    - by Ronald
    We've just upgraded our file server using an ASUS P6T WS Pro board, running FreeBSD-RELEASE 8.2 and using zfs to manage 12 WD20EARS disks. Since our 3ware card has been giving us trouble we started using the six on-board SATA connectors and got a SuperMicro USAS2-L8i to provide eight more ports. Mechanically, the card is an awkward fit but electrically it all seems ok. Upon boot, the LSI controller shows up and states that pressing ctrl-c will bring up the LSI Config Utility. When doing that, the message changes to state that the utility will be started after initialization, however that never happens. There does seem to be an error message that's only displayed too briefly to read and seems to be about PCI and "not enough space". (That message is pushed off by a hardware summary and I've found no way to scroll back at this point.) The disks do not show up in any recognizable ways after booting, either. I found a hint in another discussion to check the address mapping on either the card or the motherboard BIOS, but have found no way to do that. So what I tried on a hunch is to disable everything that's on-board, including network adapters, Firewire controller and SATA. In fact, after doing that, I can successfully launch the LSI Config Utility. As far as I can tell, all looks well in there, and when booting in that configuration it also displays a list of the disks connected to it, which looks just fine as well. Only problem now is that I can't boot that way, because I need the on-board SATA controller and network adapters. As soon as I re-enable any of them I'm back to square one. That discussion I mentioned about mapping addresses said to try D000, then D7FF, then DFFF, in order. The LSI Config Utility shows the card address as D000 but offers no way of changing it. Any tips or insights would be appreciated.

    Read the article

  • LSI MegaRAID Expected Chip Temperature?

    - by Myles Gray
    We recently built a replicating SAN array from 2x Dell R720XD's, we are using LSI 9270-8i MegaRAID cards with CacheCade 2.0, BBU and Write Back cache enabled. Our cards are showing HUGE chip temperatures (97*C+ with NO disk activity!). Our R720's are in auto temp management mode so the max exhaust temp is 50*C. The MegaRAID cards are passively cooled and depend on good airflow to cool them - however is 97*C normal? - I have seen reference to 60*C max ambients but nothing for chip temp.

    Read the article

  • How to address a recurring low temperature error seen at every boot-up?

    - by GregC
    After updating to latest controller firmware, I started receiving the following error messages: LSI 2208 ROC: Temperature sensor below error threshold on enclosure 1 Sensors 5 thru 7 Is this something I should worry about, or is it a Red Herring? Details: I have a Sans Digital NexentaSTOR 24-disk JBOD enclosure connected to LSI 9286-8e RAID-on-Chip controller with two SAS cables. Seagate ES.2 3TB SAS hard drives populate every bay in the enclosure.

    Read the article

  • LSI MegaRAID LINUX got Optimal after degradation but strange POST message

    - by kesrut
    Linux server box with LSI MegaRAID controller got degraded. But after some time RAID status changed to Optimal. Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 2.727 TB Mirror Data : 2.727 TB State : Optimal Strip Size : 256 KB Number Of Drives per span:2 Span Depth : 3 Default Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Is VD Cached: No But now I'm getting RAID BIOS POST message: Your battery is either charging, bad or missing, and you have VDs configured for write-back mode. Because the battery is not currently usable, these VDs willl actually run in write-through mode until the battery is fully charged or replaced if it is bad or missing. (Image: http://cl.ly/image/1h1O093b1i2d) So may it be battery issue caused problem ? I get information about battery: BatteryType: iBBU Voltage: 4001 mV Current: 0 mA Temperature: 22 C Battery State : Operational BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No Remaining Capacity Low : No Periodic Learn Required : No Transparent Learn : No No space to cache offload : No Pack is about to fail & should be replaced : No Cache Offload premium feature required : No Module microcode update required : No Where can be problem ? I'm disabled alarms, but get them if enabled. But don't know how find root of problem.

    Read the article

  • Disk wipe preferences

    - by hmvm123
    I manage a pool of systems that are loaded with software and sent to potential customers for evaluations which often land sensitive information on the drives. Before shipping them back, they typically like a standard wipe to be run to clean out the drives. Most are familiar with DBAN so I try to make sure it can work on my systems. Unfortunately, this means I'm usually in RAID driver hell trying to make sure that the versions out there support the ones my systems are shipping with. These are various kinds of 3ware and LSI ones. Consequently, I have DBAN 1.0.7 working on some, a beta version of 2.0 on the others and 2.2.6 on some of the latest SSD based ones. Now with the LSI controllers on my IBM x3550 M3s (1064/1068) I'm getting no love at all. Is there a way out? Do you buildroot with DBAN and try to piece the drivers together? Any other tools, free or commerical, that stay updated. I'm trying to walk people of varying technical proficiencies through this, so a boot disk with simple choices is preferable.

    Read the article

  • megacli forceWB

    - by Pascal den Bekker
    We are using a raid controller: LSI Logic / Symbios Logic MegaRAID SAS 2008 But there is no BBU on Board, is there a way to force the WB Cache ?? I tried following: - /opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp CachedBadBBU -L0 -a0 Failed to set Write Cache OK if bad BBU on Adapter 0, VD 0. FW error description: The requested command has invalid arguments. Can anyone help? Cheers, Pascal

    Read the article

  • MegaCLI always returns blank output

    - by JamesHannah
    This server is a Dell R200 running Ubuntu 8.04LTS using a LSI SAS1068E raid card supplied from Dell, I suspect that there might be some kind of RAID issue with the hardware raid built into the motherboard, but I can't seem to get MegaCLi to return any useful output: root@81 $ ./MegaCli -AdpAllInfo -aALL root@81 $ ./MegaCli -PDList -aALL root@81 $ The disks work and AFAIK the raid software is installed correctly. I've seen this issue on RedHat issues also in the past. The RAID was initially setup through the BIOS on this server and appears to be functioning fine apart from this.

    Read the article

  • Splitting a raidctl mirror safely

    - by milkfilk
    I have a Sun T5220 server with the onboard LSI card and two disks that were in a RAID 1 mirror. The data is not important right now but we had a failed disk and are trying to understand how to do this for real if we had to recover from a failure. The initial situation looked like this: # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size Level Disk ---------------------------------------------------------------- c1t0d0 136.6G N/A DEGRADED OFF RAID1 0.1.0 136.6G GOOD N/A 136.6G FAILED Green light on the 0.0.0 disk. Find / lights up the 0.1.0 disk. So I know I have a bad drive and which one it is. Server still boots obviously. First, we tried putting a new disk in. This disk came from an unknown source. Format would not see it, cfgadm -al would not see it so raidctl -l would not see it. I figure it's bad. We tried another disk from another spare server: # raidctl -c c1t1d0 c1t0d0 (where t1 is my good disk - 0.1.0) Disk has occupied space. Also the different syntax options don't change anything: # raidctl -C "0.1.0 0.0.0" -r 1 1 Disk has occupied space. # raidctl -C "0.1.0 0.0.0" 1 Disk has occupied space. Ok. Maybe this is because the disk from the spare server had a RAID 1 on it already. Aha, I can see another volume in raidctl: # raidctl -l Controller: 1 Volume:c1t1d0 (this is my server's root mirror) Volume:c1t132d0 (this is the foreign root mirror) Disk: 0.0.0 Disk: 0.1.0 ... No problem. I don't care about the data, I'll just delete the foreign mirror. # raidctl -d c1t132d0 (warning about data deletion but it works) At this point, /usr/bin/ binaries freak out. By that I mean, ls -l /usr/bin/which shows 1.4k but cat /usr/bin/which gives me a newline. Great, I just blew away the binaries (ie: binaries in mem still work)? I bounce the box. It all comes back fine. WTF. Anyway, back to recreating my mirror. # raidctl -l Controller: 1 Volume:c1t1d0 (this is my server's root mirror) Disk: 0.0.0 Disk: 0.1.0 ... Man says that you can delete a mirror and it will split it. Ok, I'll delete the root mirror. # raidctl -d c1t0d0 Array in use. (this might not be the exact error) I googled this and found of course you can't do this (even with -f) while booted off the mirror. Ok. I boot cdrom -s and deleted the volume. Now I have one disk that has a type of "LSI-Logical-Volume" on c1t1d0 (where my data is) and a brand new "Hitachi 146GB" on c1t0d0 (what I'm trying to mirror to): (booted off the CD) # raidctl -c c1t1d0 c1t0d0 (man says it's source destination for mirroring) Illegal Array Layout. # raidctl -C "0.1.0 0.0.0" -r 1 1 (alt syntax per man) Illegal Array Layout. # raidctl -C "0.1.0 0.0.0" 1 (assumes raid1, no help) Illegal Array Layout. Same size disks, same manufacturer but I did delete the volume instead of throwing in a blank disk and waiting for it to resync. Maybe this was a critical error. I tried selecting the type in format for my good disk to be a plain 146gb disk but it resets the partition table which I'm pretty sure would wipe the data (bad if this was production). Am I boned? Anyone have experience with breaking and resyncing a mirror? There's nothing on Google about "Illegal Array Layout" so here's my contrib to the search gods.

    Read the article

  • Does the Intel DX79TO motherboard support x8 devices (SAS HBAs) on PCIe x16 slots?

    - by Zac B
    Context: I have an Intel DX79TO motherboard and a Sun SAS3081E-S/LSI 1060E-S HBA card with a PCIe x8 interface. I plug the HBA into my mobo next to my graphics card, and the HBA power lights illuminate, but the BIOS and OSes (tried Linux, ESXi, Win7) don't see the HBA at all. Question: Does the DX79TO motherboard support non-x16/non-GPU devices in its PCIe x16 slots? According to this question, some consumer motherboards don't support this, but I can't figure out whether or not this motherboard/family does. The answer will affect whether I buy a new motherboard or RMA the SAS card, with money attached to each course, so I figured I'd ask here first. What I've Tried: I've read the spec/manuals for the motherboard and the HBA, and I didn't see anything regarding whether or not the x16 slots were back-compatible to lower lane widths/non graphics-card devices, or whether or not the card could run in wider slots than x8. I've tried contacting Intel, but that was over a month ago and I haven't yet heard anything back except an automated "we got your email!" message.

    Read the article

  • LSI1068E hidden drives after failed raid volume creation

    - by silk
    We are using LSI 1068E raid chipset with SAS drives. We had added new drives to the system, and tried to create new raid volume with the lsiutil, unfortunately the creation failed. The problem is that now we do not have the new raid volume and disks 'disappeared' and are not available as targets for raid. Lsiutil option 8 (scan for devices) does not display these disks at all. lsiutil option 16 (display attached devices) does list them as targets. lsiutil option 21+30 (create raid) does not list these disks. Just after insrting them to enclosure these disks appeared in the system, as expected. During the raid creation kernel logged: Mar 4 08:40:02 kilo kernel: [57555.687946] mptbase: ioc0: RAID STATUS CHANGE for PhysDisk 2 id=0 Mar 4 08:40:02 kilo kernel: [57555.687978] mptbase: ioc0: PhysDisk has been created Mar 4 08:40:02 kilo kernel: [57555.695438] scsi target0:0:2: mptsas: ioc0: RAID Hidding: fw_channel=0, fw_id=0, physdsk 2, sas_addr 0x5000c50008ebe5fd for both of them, again as expected. Unfortunately they did not appear back even though the volume was not created. The same situation is in the controller's bios after a reboot. Taking the disks out and inserting in different slots did not help, either. Has someone seen a similar problem? And knows how to 'get back' our disks?

    Read the article

  • 4096 and 8192 block size read slower than write? by using lsi 9361-8i RAID10

    - by Min Hong Tan
    is it possible that 1024 and 2048 block size read speed is faster than 4096 and 8192 block? I'm using lsi 9361-8i with RAID 10 , with 8 x Kingston E50 250G. result: 1024 = Write: 2,251 MB/s Read: 2,625 MB/s 2048 = Write: 2,141 MB/s Read: 3,672 MB/s 4096 = Write: 2,147 MB/s Read: 231 MB/s 8192 = Write: 2,147 MB/s Read: 442 MB/s is there any possible? and below is the reading when i simply want to test out the RAID 10 function and disaster test by taking out one of the 250G harddisk. the result is different like below: Result: 1024 = Write: 825 MB/s Read: 1,139 MB/s 2048 = Write: 797 MB/s Read: 1,312 MB/s 4096 = Write: 911 MB/s Read: 1,342 MB/s 8192 = Write: 786 MB/s Read: 1,204 MB/s and the result for 4096 and 8192block are different? can any one explain to me is it normal? or I need to do some tuning/configuration? will it affect my host linux performance?

    Read the article

  • How does Linux determine the SCSI address of a disk?

    - by Chris Sears
    Greetings, I'm working with RHEL 5.5 guest VMs under VMware ESX 4. When I configure the virtual disks in the VM hardware settings, each disk has a SCSI address in the format "N:M". For example, "1:3" would mean SCSI host number 1 and SCSI target ID 3. When I look at the disk info from the VM's BIOS or a Windows OS, the detected SCSI address info matches up with the virtual hardware settings. But under Linux, the SCSI address components don't match up, at least not completely or consistently. I've tried the three supported virtual SCSI and SAS drivers and they all seem to be "broken", but in different ways. Here's a list of the virtual hardware addresses vs what was detected under Linux with each of the drivers: Driver vHW Addr Linux Addr -------- -------- ---------- LSI SAS 0:0 0:0 LSI SAS 0:3 0:1 LSI SAS 0:6 0:2 LSI SCSI 1:1 2:1 LSI SCSI 1:4 2:4 LSI SCSI 1:7 2:7 pvSCSI 2:2 1:2 pvSCSI 2:5 1:5 pvSCSI 2:8 1:8 My main question is why does this happen under Linux? The next question is: how do I get it fixed or fix it myself? If I was going to guess, I'd say it's an issue with how the kernel is handing out the SCSI host number and how the Linux SCSI driver (included with VMware tools) is detecting the SCSI target number. Perhaps the order the drivers are loaded also has something to do with the issue. I'm guessing this would not involve udev, but I could be wrong. Any thoughts would be appreciated. Thanks! PS. My environment is VMware, but I don't need an answer for these drivers specifically. I imagine this might be a problem with any SCSI driver under Linux.

    Read the article

  • What Does Latent Semantic Indexing Really Mean?

    Too many article writers are completely misunderstanding what latent semantic indexing is all about, and many people seem to be under the impression that LSI is something an SEO article service can produce. Once and for all, let's get it quite clear what LSI is all about...

    Read the article

  • SSDs at PASS 2012

    - by jchang
    There were 7 companies exhibiting SSD products as PASS this year, and one with a product to support SSD storage. This is not counting Dell, EMC and HP who have SSD products, but were at PASS for other reasons. This shows that many have aspirations with the hope that market leadership is not yet firmly set. The products fall into the following: PCI-E SSDs (Fusion-io, LSI, Virident) SSD SAN (Violin, TMS, Whiptail) SSD caching (LSI, GridIron) I am inclined to be of the opinion that SSD market is not...(read more)

    Read the article

  • Linux: How to delay hddtemp service start at boot until all hdd are visible?

    - by Atis
    I live in a hot and humid environment, therefore I monitor the hdd temperature using hddtemp and gkrellm. There is an LSI9211 8i sata/sas controller in my computer. I have drives connected to both my motherboard and the LSI. hddtemp monitors only the drives directly connected to my motherboard after booting the system, therefore gkrellm displays the temperature of those drvies only. Logging in and restarting hddtemp before starting gkrellm fixes my issue, i.e. drives connected to the LSI controller are also visible. It seems that the drives connected to the LSI controller become visible only after hddtemp is started in the boot sequence. I think delaying it would help. How can I delay the starting of hddtemp till all drives are visible? I prefer a way to check if drives are visible to the delay of a specific amount of seconds.

    Read the article

  • What driver for M1015 for Solaris 11 Express

    - by Garuda
    For Solaris 11 Express, what driver is supposed to be used? The M1015 is essentially a LSI 9240-8i From http://www.lsi.com/products/storagecomponents/Pages/MegaRAIDSAS9240-8i.aspx The only driver for Solaris is a old 32bit driver? I'd like to Flash it also, but can't seem to figure out which util to use.. The linux one from IBM screams for libraries that aren't included in the libraries section.

    Read the article

  • Windows Server 2008 R2 install reboots unexpectedly during "Completing installation" phase

    - by knda
    I am attempting to install Windows Server 2008 R2 onto a Cisco UCS C201 M2 rack mounted server but am having major difficulties and wondering if anyone has some insight or items they could recommend for me to look at to get this one resolved. Installation is being attempted via the Cisco remote console (using CIMC's Virtual dvd-rom).. following the first phase of Setup where the installation files are copied to the target hard drive, then a reboot occurs to load Setup from the HDD, mid-way in the "Completing Installation" phase the system then reboots unexpectedly. System configuration Cisco UCS C201 M2 (2RU rack mounted server) 16GB RAM, 2x 73GB 15K SAS, 4x 300GB 10k SAS Add-on cards - Intel quad-port GigE card (no fibre channel cards) Storage - LSI MegaRAID SAS 9261-8i. onboard SATA is disabled (no SATA drives connected) KVM - Belkin No physical DVD-ROM.. :( I have... Run memtest86+, no RAM faults Disabled/enabled SATA support (BIOS) Attempted install from USB DVD-ROM, no effect Attempted unattended install scripted via Cisco Configuration Manager DVD provided Removed Belkin KVM in case that was causing drama Discovered that the Cisco website is "awesome" for searching for PDFs/Drivers cough, reverted back to Google Downloaded latest LSI drivers from LSI's site and used during Server 2008 install checked Windows ISO against checksum's from MS site checked Windows ISO by using it for an install in a VM Running out of ways to troubleshoot this as I am not sure how to enable any sort of 'verbose' mode during the setup process. Next step I have planned is to remove the Intel NIC and try the installation again.. Edit: Problem was the "Cisco INTEL QUAD PT GBE" (1000/PT) .. will have to see if this card is faulty or if it's just drivers.. thanks for the help.

    Read the article

  • Install MegaCli to Monitor Perc 5/i in Nexentastor 3

    - by Peter Valadez
    I have a Dell 2950 with a Perc 5/i Raid controller that we've already installed Nexentastor 3 Community Edition on. We setup a raid-10 array that and put a ZFS pool on top of the hardware. As I understand, in this configuration ZFS/Nexentastor will not be able to tell when a disk fails in the array. Obviously, this is not optimal. Since the Dell Perc 5/i controller is a rebranded LSI controller, you should be able to use the MegaCli utility to manage the array and monitor its condition. I had seen in a separate forum that the Perc 5/i is very similar to the LSI MegaRAID 8480E, so I tried installing the MegaCli utility at the link below. However, I have not been able to successfully install the utility. http://www.lsi.com/support/products/Pages/MegaRAIDSAS8480E.aspx Here is what happened when I tried to install MegaCli: root@Nexenta2:/files# pkgadd -d MegaCli.pkg Warning: unable to relocate '$BASEDIR' mv: cannot move `solmegacli-8.02.16/' to a subdirectory of itself, `solmegacli-8.02.16//var/lib/dpkg/alien/solmegacli/reloc/solmegacli-8.02.16' mv: cannot move `solmegacli-8.02.16/' to a subdirectory of itself, `solmegacli-8.02.16//opt/solmegacli-8.02.16' 822-date: warning: This program is deprecated. Please use 'date -R' instead. 822-date: warning: This program is deprecated. Please use 'date -R' instead. solmegacli_8.02.16-1_all.deb generated (Reading database ... 41397 files and directories currently installed.) Preparing to replace solmegacli 8.02.16-1 (using solmegacli_8.02.16-1_all.deb) ... Unpacking replacement solmegacli ... Setting up solmegacli (8.02.16-1) ... In /var/logs/dpkg.log: 2012-03-23 20:40:19 status unpacked solmegacli 8.02.16-1 2012-03-23 20:40:19 configure solmegacli 8.02.16-1 8.02.16-1 2012-03-23 20:40:19 status unpacked solmegacli 8.02.16-1 2012-03-23 20:40:19 status half-configured solmegacli 8.02.16-1 2012-03-23 20:40:19 status installed solmegacli 8.02.16-1 So... I've got three questions: Is it possible to install and use MegaCli in Nexentastor 3? If so, how can I install MegaCli on Nexentastor 3? Suggestions welcome!!! If not, is there a better way to monitor the condition of the Perc 5/i hardware raid? Our 2950 does have a DRAC card, so can I use that to monitor the raid condition?

    Read the article

  • RHEL 5.x SCSI Driver .img update for initrd.img

    - by zmische
    I have production DB server (RHEL 5.1) with LSI Megaraid driver loaded during setup via DUD (Driver Upd Diskett). Now I'd like to update kernel and other packeges to 5.4 version. I also downloaded new LSI SCSI driver (megasr-13.11.0922.2009-1-rhel50-u4-all.img ). Could you explain the necessary steps to make this driver visible on boot for new kernel (lets assume, that I've already update kernel to 5.4)? I read the article on Redhat - "How do I add a driver to the initrd.img". Does it contain all the steps I need? Thanks in advance!

    Read the article

  • Getting FC11 to run under VMware Server, converted from physical machine

    - by Kristian
    I have a FC11 installation that I have converted to a VMware disk image to run om my VMware Server. I converted it with qemu-img, as the VMware Converter software apparently only converts Linux hosts to VMware Infrastructure servers. The disk image boots fine (grub is loaded and boots the kernel) but it seems like the disk is not found by the kernel, and the boot process stalls. Hotplugging USB devices work (the kernel prints debug information) and I'm able to press keys (Ctrl-Alt-Delete for instance). The VMware guest OS is set to RedHat Enterprise Linux 5 (32 bit), and I have tried both the LSI Logic, LSI Logic SAS and VMware Accelerated SCSI SCSI controllers, to no avail. I'm able to boot an installer disk and get into rescue mode and mount the filesystem, so my question is, what do I need to do to the guest kernel / initrd image to make it recognize the virtual disk?

    Read the article

  • Disk names in Solaris 10 for ZFS: SAS WWN instead of c0t0d0

    - by notpeter
    I currently have a server running Solaris 10u9 with a SAS enclosure (Dell PowerVault MD1000) filled with SATA disks attached to an SAS card (LSI 3801E). It happily recognizes the 15 disks in the MD1000 and presents them each disk in the traditional solaris form (c1t12d0, c1t13d0, c1t15d0, etc). My home ZFS setup (Nexenta CP3 + LSI 9200-16E + directly cabled SATA disks) presents disks as their SAS WWN ID (ex: c3t600039300001EA56d0). Although this ID is longer, I've found it much easier to troubleshoot because the cabling/slot is irrelevant, ZFS just identifies the disk by ID, if it's connected it finds it. Most manufacturers print the WWN right on the disk's top label, can't get much easier than that. So how can I get Solaris to identify disks by SAS WWN instead of by the cXtXdX?

    Read the article

  • Slow disk transfer rate

    - by Nooklez
    I have problem with slow disk transfer rate. It's static files server for our website. I was making backup of data and noticed that tar is very slow. So I did hdparm -t and... hdparm -t /dev/sda3 /dev/sda3: Timing buffered disk reads: 6 MB in 4.70 seconds = 1.28 MB/sec It's low traffic hour now on our site, so huge I/O traffic is not a reason (iotop show less than 1 MB/s). It's RAID10 setup (2x2 SATA drives). Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy ------------------------------------------------------------------------------ u0 RAID-10 OK - - 64K 1396.96 W ON VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 698.63 GB SATA 0 - WDC WD7500AADS-00M2 p1 OK u0 698.63 GB SATA 1 - WDC WD7500AADS-00M2 p2 OK u0 698.63 GB SATA 2 - WDC WD7500AADS-00M2 p3 OK u0 698.63 GB SATA 3 - WDC WD7500AADS-00M2 We have recently changed almost all components of server (excluding 3ware controller + disks). And I think problems started since then. Can it be configuration problem or hardware? EDIT: I found something like that in dmesg [166843.625843] irq 16: nobody cared (try booting with the "irqpoll" option) [166843.625846] Pid: 0, comm: swapper Not tainted 3.1.5-gentoo #3 [166843.625847] Call Trace: [166843.625848] <IRQ> [<ffffffff810859d5>] __report_bad_irq+0x35/0xc1 [166843.625856] [<ffffffff81085cec>] note_interrupt+0x165/0x1e1 [166843.625859] [<ffffffff8108445f>] handle_irq_event_percpu+0x16f/0x187 [166843.625861] [<ffffffff810844a9>] handle_irq_event+0x32/0x51 [166843.625863] [<ffffffff8108640b>] handle_fasteoi_irq+0x75/0x99 [166843.625866] [<ffffffff810039d7>] handle_irq+0x83/0x8b [166843.625868] [<ffffffff810036ad>] do_IRQ+0x48/0xa0 [166843.625871] [<ffffffff8155082b>] common_interrupt+0x6b/0x6b [166843.625872] <EOI> [<ffffffff812981e8>] ? acpi_safe_halt+0x22/0x35 [166843.625877] [<ffffffff812981e2>] ? acpi_safe_halt+0x1c/0x35 [166843.625879] [<ffffffff81298216>] acpi_idle_do_entry+0x1b/0x2b [166843.625881] [<ffffffff81298276>] acpi_idle_enter_c1+0x50/0x99 [166843.625884] [<ffffffff813b792a>] cpuidle_idle_call+0xed/0x171 [166843.625886] [<ffffffff81001257>] cpu_idle+0x55/0x81 [166843.625888] [<ffffffff81532a69>] rest_init+0x6d/0x6f [166843.625891] [<ffffffff81aa1aca>] start_kernel+0x329/0x334 [166843.625893] [<ffffffff81aa12a6>] x86_64_start_reservations+0xb6/0xba [166843.625894] [<ffffffff81aa139c>] x86_64_start_kernel+0xf2/0xf9 [166843.625896] handlers: [166843.625898] [<ffffffff812dc8de>] twl_interrupt [166843.625900] Disabling IRQ #16 It's related to problem? EDIT #2: Based on feedback in comments, here is more informations. cat /proc/interrupts 16: 390813 0 0 0 IO-APIC-fasteoi 3w-sas Controller model: [ 1.095350] 3ware Storage Controller device driver for Linux v1.26.02.003. [ 1.095467] 3ware 9000 Storage Controller device driver for Linux v2.26.02.014. [ 1.095641] LSI 3ware SAS/SATA-RAID Controller device driver for Linux v3.26.02.000. [ 1.095787] 3w-sas 0000:01:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 1.095881] 3w-sas 0000:01:00.0: setting latency timer to 64 [ 1.910801] 3w-sas: scsi0: Found an LSI 3ware 9750-4i Controller at 0xfe560000, IRQ: 16. [ 2.216537] 3w-sas: scsi0: Firmware FH9X 5.08.00.008, BIOS BE9X 5.07.00.011, Phys: 8. [ 2.216836] scsi 0:0:0:0: Direct-Access LSI 9750-4i DISK 5.08 PQ: 0 ANSI: 5 And motherboard: description: Motherboard product: P8H67-M vendor: ASUSTeK Computer INC.