  • Access RAID configuration in x3550M2

    - by Mike B
    I'm trying to configure RAID in a IBM x3550 M2 server. I can't find any messages on boot about any hotkey to access the configuration utility. I wasn't able either in BIOS. The card is a on board LSI 1068e. I can't find the original CD's shipped with the server, but I downloaded Server Guide 9.21 from IBM web. Booted with that, and only getting stuck at "Windows loading"p. Tried with a 8.? version from a x3550 (M1), but it was less useful. Although I do not consider myself an expert, I'm starting to feel like a newbie luser. Any help?

    Read the article

  • Iozone: sensible settings for a server with lots of RAM

    - by Frank Brenner
    I have just acquired a server with: 2x quadcore Xeons 48G ECC RAM 5x 160GB SSDs on an LSI 9260-8i Before deploying the target platform, I'd like to collect as much benchmark data as possible, testing I/O with hardware RAID in various configurations, ZFS zRAID, as well as I/O performance on vSphere and with KVM virtualization. In order to see real disk I/O performance without cache effects, I tried running Iozone with a maximum file of more than twice the physical RAM as recommended in the documentation, so: iozone -a -g100G However, as one might expect, this takes far too long to be practicable. (I stopped the run after seven hours..) I'd like to reduce the range of record and file sizes to values that might reflect realistic performance for an application server, hopefully getting the run times to under an hour or so. Any ideas? Thanks.

    Read the article

  • RAID10 Without BBU, With UPS

    - by Richard
    My datacenter says that each rack has primary and backup power on each rack. I assume this means there is a UPS for each server. Therefore, do I have any need of getting a BBU for the following setup? Intel Cherry 520 SSD x 4 RAID 10 LSI-9260 with WRITEBACK CACHE ENABLED I have heard that without a BBU the data in the cache could be lost. Since my needs aren't mission-critical, I can afford to lose some data. But would the rest of the data on the HD be corrupted?

    Read the article

  • Disk controller speed responsible for slow write speeds?

    - by vizvayu
    I have question. I'm using ESXi 4.0U1 in an IBM x3200M2 with an integrated LSI 1064e RAID controller, without any kind of cache. I have 3 250GB HOT-SWAP SATA HDs configured in RAID1E (IME). ESXi works fine, read speed are quite OK, but write speeds are incredible slow, never more than 8MB/s, and this is the best case scenario, benchmarking with iozone streaming writes, using a VMWare Paravirtual controller and with only this VM active, no swapping of any kind (total vm memory reserved). Already wrote to IBM but I don't have any kind of pay support so they didn't even answered, so I'm just wondering... anybody has any experience with a similar setup? I just want to be sure this is hardware related and can't be fixed with some kind of config option, because I'm thinking on buying a new RAID controller (Adaptec 2405 looks nice). Thanks again!

    Read the article

  • Server spec for a small business [duplicate]

    - by I'll-Be-Back
    This question already has an answer here: Can you help me with my capacity planning? 2 answers I will need to buy a decent server for Windows Server 2012 and Linux for Web server (Internal use only - Intranet). I will install ESXi with 2 or 3 VM's. There will be about 80-100 Agents at work, they will login (domain controller) on client PC in the morning (between 9:40am to 10:05am). They can only use IE browser and everything else will be locked. They will not have any storage space, no email, etc. Is this spec decent enough? 2u Supermicro 825 chassis, X9SCL-F x1 Intel E3-1290v2 16Gb DDR3 x2 Intel 520 Series 240Gb x2 2Tb Seagate Barracuda, LSi 4 port SAS raid controller

    Read the article

  • Why might one hard disk perform slower than another?

    - by Styne666
    I have just bought two WD 3TB Reds (WD30EFRX) for a FreeNAS box and whilst doing burn-in testing it seems like one is consistently taking about 10% longer than the other. So far I've done: a dd read test of the whole device, a long SMART test and it's currently halfway through a badblocks -wvs. The second device is lagging behind the first on all of them. I'm running these commands on Debian stable in two Konsole tabs. Is there a reason this could be considered normal behaviour or is it worth running the tests independantly? They're both plugged in to the LSI 2308 (IT mode) on a Supermicro X10SL7-F.

    Read the article

  • It's an Oracle Linux Wrap: Oracle Openworld 2012

    - by Zeynep Koch
    Are you still recovering from an amazing Oracle OpenWorld experience? 50,000 attendees had access to thousands of sessions, demos, hands-on-labs, networking opportunities, music concerts, and loads of fun. For the Oracle Linux team, this was a week full of many insightful sessions and customer interactions. In case you were unable to attend Oracle OpenWorld or missed some of content presented, here's a compilation of key session presentations, keynotes, and videos.Go to the Oracle OpenWorld content catalog and access all the session presentations. Oracle Openworld Keynote by Edward Screven Oracle's commitment to Open Source by Edward Screven Oracle Linux Interview with Wim Coekaerts Making the most of mainline kernel by Wim Coekaerts Why DTrace and Ksplice have made Oracle Linux 6 popular by W.Coekaerts How partnership between Oracle Linux and Oracle Partners benefits Sysadmins by Michele Resta Hugepages=Huge Performance on Oracle Linux by Greg Marsden Benefits of Kpslice in your Linux Environment by Tim Hill Oracle Linux, Ksplice and MySQL by Lenz Grimmer We also hosted a successful Oracle Linux Pavilion with 11 of our key partners - Beyond Trust, Centrify, Data Intensity, Fujitsu, HP, LSI, Mellanox, Micro Focus, NetApp, QLogic and Teleran showcased their solutions for Oracle Linux and Oracle VM. Here are some videos from the Oracle Linux Pavilion. Centrify covers Oracle Linux solution they offer at Oracle Linux PavilionMellanox talk about their solution at Oracle Linux Pavilion Eric Pan covers Micro Focus products at Oracle Linux Pavilion There's also collection of the keynotes and executive sessions as on-demand videos posted  here . We hope you find this information useful and look forward to seeing at Oracle OpenWorld 2013! ORACLE LINUX TEAM

    Read the article

  • VISIT ORACLE LINUX PAVILION @ORACLE OPENWORLD

    - by Zeynep Koch
    Back by popular demand, Oracle will again host the Oracle Linux Pavilionat Oracle OpenWorld from October 1-3. The pavilion will be located in the Exhibition Hall at Moscone South, Booth 1033, next to the Oracle DEMOgrounds and Oracle Linux demopods. At the pavilion a select group of ISVs, IHVs, and SIs will showcase their products that have been Oracle Linux- and/or Oracle VM-certified. These certified products enable customer applications to run faster, thereby saving money.Partners exhibiting their solutions in the Oracle Linux Pavilion include: BeyondTrust: context-aware security intelligence for dynamic IT infrastructures such as cloud, mobile, and virtual technologies Centrify: control, secure, and audit access to cross-platform systems, mobile devices, and applications Data Intensity: cloud services and application management Fujitsu: technology platforms, private cloud, services, ubiquitous and device solutions HP: converged cloud, converged infrastructure, application transformation, and information optimization LSI: intelligent solid-state storage solutions for breakthrough database acceleration Mellanox: InfiniBand and Ethernet end-to-end server and storage interconnect solutions and services for data centers Micro Focus: mainframe solutions, application modernization and development tools, software quality tools NetApp: storage and data management QLogic: high performance networking Teleran: BI and data warehouse management solutions for Oracle Exadata Database Machine and Oracle Database Be sure to pick up your free Oracle Linux and Oracle VM DVD Kit if you visit one of these partners. And speaking of free, be sure to stop by for some cool treats, courtesy of sponsor QLogic: Smoothie Bar on Monday, October 1 from 2:30 p.m. - 5:30p.m. Ice Cream Social on Wednesday, October 3 from 1:00 p.m. - 2:00 p.m. We look forward to seeing you at the pavilion.

    Read the article

  • Oracle Linux Pavilion is Back for Oracle OpenWorld

    - by Oracle OpenWorld Blog Team
    By Zeynep Koch Back by popular demand, Oracle will again host the Oracle Linux Pavilion at Oracle OpenWorld from October 1-3. The pavilion will be located in the Exhibition Hall at Moscone South, Booth 1033, next to the Oracle DEMOgrounds and Oracle Linux demopods. At the pavilion a select group of ISVs, IHVs, and SIs will showcase their products that have been Oracle Linux- and/or Oracle VM-certified. These certified products enable customer applications to run faster, thereby saving money.Partners exhibiting their solutions in the Oracle Linux Pavilion include: BeyondTrust: context-aware security intelligence for dynamic IT infrastructures such as cloud, mobile, and virtual technologies Centrify: control, secure, and audit access to cross-platform systems, mobile devices, and applications Data Intensity: cloud services and application management Fujitsu: technology platforms, private cloud, services, ubiquitous and device solutions HP: converged cloud, converged infrastructure, application transformation, and information optimization LSI: intelligent solid-state storage solutions for breakthrough database acceleration Mellanox: InfiniBand and Ethernet end-to-end server and storage interconnect solutions and services for data centers Micro Focus: mainframe solutions, application modernization and development tools, software quality tools NetApp: storage and data management QLogic: high performance networking Teleran: BI and data warehouse management solutions for Oracle Exadata Database Machine and Oracle Database Be sure to pick up your free Oracle Linux and Oracle VM DVD Kit if you visit one of these partners. We look forward to seeing you at the pavilion.

    Read the article

  • Audio comes out of both headphone and speaker at the same time.. Ubuntu 12.04LTS [closed]

    - by pst007x
    I have the same issue on an Aspire. Ubuntu 12.04LTS 64bit realtek audio sound chip onboard If I plug in a headset, audio does not switch from internal speaker to headset, instead plays out of both at the same time. I have looked at the alsamixer setting, all on. I installed gnome-alsamixer, and I noticed headphone was ticked, if I untick the main audio mutes, and the headphone no longer works. Headset only works with internal speaker. Audio works fine on my other desktop and laptop running this release 00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) salvatore@salvatore-Aspire-7730:~$ cat /proc/asound/version Advanced Linux Sound Architecture Driver Version 1.0.24. salvatore@salvatore-Aspire-7730:~$ head -n 1 /proc/asound/card*/codec#* ==> /proc/asound/card0/codec#0 <== Codec: Realtek ALC888 ==> /proc/asound/card0/codec#1 <== Codec: LSI ID 1040 ==> /proc/asound/card0/codec#2 <== Codec: Intel Cantiga HDMI salvatore@salvatore-Aspire-7730:~$ aplay -l **** List of PLAYBACK Hardware Devices **** card 0: Intel [HDA Intel], device 0: ALC888 Analog [ALC888 Analog] Subdevices: 1/1 Subdevice #0: subdevice #0 card 0: Intel [HDA Intel], device 1: ALC888 Digital [ALC888 Digital] Subdevices: 1/1 Subdevice #0: subdevice #0 card 0: Intel [HDA Intel], device 3: HDMI 0 [HDMI 0] Subdevices: 1/1 Subdevice #0: subdevice #0 salvatore@salvatore-Aspire-7730:~$ uname -a Linux salvatore-Aspire-7730 3.2.0-23-generic #36-Ubuntu SMP Tue Apr 10 20:39:51 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux salvatore@salvatore-Aspire-7730:~$ The alsa-base.conf does not exist Tried this: sudo apt-get remove --purge alsa-base sudo apt-get remove --purge pulseaudio sudo apt-get install alsa-base sudo apt-get install pulseaudio sudo alsa force-reload Then: sudo apt-get purge pulseaudio gstreamer0.10-pulseaudio sudo apt-get install pulseaudio gstreamer0.10-pulseaudio indicator-sound Tred this. sudo gedit Then open terminal: sudo /etc/modprobe.d/alsa-base.conf At the end of the file add a new line: options snd-hda-intel model=generic Save and then reboot But alsa-base.conf does not exist

    Read the article

  • lshw not showing network

    - by triunenature
    Output: {User}@{Computer}:~$ sudo lshw -class network {User}@{Computer}:~$ Another Test: {User}@{Computer}:~$ lspci 00:00.0 RAM memory: NVIDIA Corporation MCP61 Memory Controller (rev a1) 00:01.0 ISA bridge: NVIDIA Corporation MCP61 LPC Bridge (rev a2) 00:01.1 SMBus: NVIDIA Corporation MCP61 SMBus (rev a2) 00:01.2 RAM memory: NVIDIA Corporation MCP61 Memory Controller (rev a2) 00:02.0 USB controller: NVIDIA Corporation MCP61 USB 1.1 Controller (rev a3) 00:02.1 USB controller: NVIDIA Corporation MCP61 USB 2.0 Controller (rev a3) 00:04.0 PCI bridge: NVIDIA Corporation MCP61 PCI bridge (rev a1) 00:05.0 Audio device: NVIDIA Corporation MCP61 High Definition Audio (rev a2) 00:06.0 IDE interface: NVIDIA Corporation MCP61 IDE (rev a2) 00:07.0 Bridge: NVIDIA Corporation MCP61 Ethernet (rev a2) <<---- Network Card???? 00:08.0 IDE interface: NVIDIA Corporation MCP61 SATA Controller (rev a2) 00:08.1 IDE interface: NVIDIA Corporation MCP61 SATA Controller (rev a2) 00:09.0 PCI bridge: NVIDIA Corporation MCP61 PCI Express bridge (rev a2) 00:0b.0 PCI bridge: NVIDIA Corporation MCP61 PCI Express bridge (rev a2) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 01:05.0 FireWire (IEEE 1394): LSI Corporation FW322/323 (rev 70) 02:00.0 VGA compatible controller: NVIDIA Corporation G96 [GeForce 9500 GT] (rev a1) If you look at 00:07.0 I believe that is the network card. However lshw doesnt show it. I mainly need information on network speed 10MBpS/100MBsP/1000MBpS Though knowing why my system isn't working would be nice.

    Read the article

  • UnmarshalException: unexpected element

    - by Tom Brito
    I'm working with JAXB, and I'm having trouble to unmarshall a file; The following lines, on the beginning of the file, are causing trouble: <!DOCTYPE package PUBLIC "+//ISBN 0-9673008-1-9//DTD OEB 1.2 Package//EN" "http://openebook.org/dtds/oeb-1.2/oebpkg12.dtd"> <package xmlns="http://openebook.org/namespaces/oeb-package/1.0/" unique-identifier="uid"> If I delete all the !DOCTYPE it gives no Exception, but it doesn't load any value either. The program (with the !DOCKTYPE) is throwing the exeption: javax.xml.bind.UnmarshalException: unexpected element (uri:"http://openebook.org/namespaces/oeb-package/1.0/", local:"package"). Expected elements are <{}dc-metadata>,<{}dc:Contributor>,<{}dc:Coverage>,<{}dc:Creator>,<{}dc:Date>,<{}dc:Description>,<{}dc:Format>,<{}dc:Identifier>,<{}dc:Language>,<{}dc:Publisher>,<{}dc:Relation>,<{}dc:Rights>,<{}dc:Source>,<{}dc:Subject>,<{}dc:Title>,<{}dc:Type>,<{}guide>,<{}item>,<{}itemref>,<{}manifest>,<{}meta>,<{}metadata>,<{}package>,<{}reference>,<{}site>,<{}spine>,<{}tour>,<{}tours>,<{}x-metadata> at com.sun.xml.internal.bind.v2.runtime.unmarshaller.UnmarshallingContext.handleEvent(UnmarshallingContext.java:631) at com.sun.xml.internal.bind.v2.runtime.unmarshaller.Loader.reportError(Loader.java:236) at com.sun.xml.internal.bind.v2.runtime.unmarshaller.Loader.reportError(Loader.java:231) at com.sun.xml.internal.bind.v2.runtime.unmarshaller.Loader.reportUnexpectedChildElement(Loader.java:105) at com.sun.xml.internal.bind.v2.runtime.unmarshaller.UnmarshallingContext$DefaultRootLoader.childElement(UnmarshallingContext.java:1038) at com.sun.xml.internal.bind.v2.runtime.unmarshaller.UnmarshallingContext._startElement(UnmarshallingContext.java:467) at com.sun.xml.internal.bind.v2.runtime.unmarshaller.UnmarshallingContext.startElement(UnmarshallingContext.java:448) at com.sun.xml.internal.bind.v2.runtime.unmarshaller.SAXConnector.startElement(SAXConnector.java:137) at com.sun.org.apache.xerces.internal.parsers.AbstractSAXParser.startElement(AbstractSAXParser.java:501) at com.sun.org.apache.xerces.internal.impl.dtd.XMLDTDValidator.startElement(XMLDTDValidator.java:767) at com.sun.org.apache.xerces.internal.impl.XMLNSDocumentScannerImpl.scanStartElement(XMLNSDocumentScannerImpl.java:400) at com.sun.org.apache.xerces.internal.impl.XMLNSDocumentScannerImpl$NSContentDriver.scanRootElementHook(XMLNSDocumentScannerImpl.java:626) at com.sun.org.apache.xerces.internal.impl.XMLDocumentFragmentScannerImpl$FragmentContentDriver.next(XMLDocumentFragmentScannerImpl.java:3103) at com.sun.org.apache.xerces.internal.impl.XMLDocumentScannerImpl$PrologDriver.next(XMLDocumentScannerImpl.java:922) at com.sun.org.apache.xerces.internal.impl.XMLDocumentScannerImpl.next(XMLDocumentScannerImpl.java:648) at com.sun.org.apache.xerces.internal.impl.XMLNSDocumentScannerImpl.next(XMLNSDocumentScannerImpl.java:140) at com.sun.org.apache.xerces.internal.impl.XMLDocumentFragmentScannerImpl.scanDocument(XMLDocumentFragmentScannerImpl.java:511) at com.sun.org.apache.xerces.internal.parsers.XML11Configuration.parse(XML11Configuration.java:808) at com.sun.org.apache.xerces.internal.parsers.XML11Configuration.parse(XML11Configuration.java:737) at com.sun.org.apache.xerces.internal.parsers.XMLParser.parse(XMLParser.java:119) at com.sun.org.apache.xerces.internal.parsers.AbstractSAXParser.parse(AbstractSAXParser.java:1205) at com.sun.org.apache.xerces.internal.jaxp.SAXParserImpl$JAXPSAXParser.parse(SAXParserImpl.java:522) at com.sun.xml.internal.bind.v2.runtime.unmarshaller.UnmarshallerImpl.unmarshal0(UnmarshallerImpl.java:200) at com.sun.xml.internal.bind.v2.runtime.unmarshaller.UnmarshallerImpl.unmarshal(UnmarshallerImpl.java:173) at javax.xml.bind.helpers.AbstractUnmarshallerImpl.unmarshal(AbstractUnmarshallerImpl.java:137) at javax.xml.bind.helpers.AbstractUnmarshallerImpl.unmarshal(AbstractUnmarshallerImpl.java:142) at javax.xml.bind.helpers.AbstractUnmarshallerImpl.unmarshal(AbstractUnmarshallerImpl.java:151) at javax.xml.bind.helpers.AbstractUnmarshallerImpl.unmarshal(AbstractUnmarshallerImpl.java:169) at br.usp.lsi.pdtb.protector.view.ProtectorView.showBookData(ProtectorView.java:55) at br.usp.lsi.pdtb.protector.ProtectorImpl.openBook(ProtectorImpl.java:43) at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method) at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:39) at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25) at java.lang.reflect.Method.invoke(Method.java:597) at tomPack.swing.TomAction.actionPerformed(TomAction.java:115) at javax.swing.AbstractButton.fireActionPerformed(AbstractButton.java:1995) at javax.swing.AbstractButton$Handler.actionPerformed(AbstractButton.java:2318) at javax.swing.DefaultButtonModel.fireActionPerformed(DefaultButtonModel.java:387) at javax.swing.DefaultButtonModel.setPressed(DefaultButtonModel.java:242) at javax.swing.plaf.basic.BasicButtonListener.mouseReleased(BasicButtonListener.java:236) at java.awt.AWTEventMulticaster.mouseReleased(AWTEventMulticaster.java:272) at java.awt.Component.processMouseEvent(Component.java:6263) at javax.swing.JComponent.processMouseEvent(JComponent.java:3267) at java.awt.Component.processEvent(Component.java:6028) at java.awt.Container.processEvent(Container.java:2041) at java.awt.Component.dispatchEventImpl(Component.java:4630) at java.awt.Container.dispatchEventImpl(Container.java:2099) at java.awt.Component.dispatchEvent(Component.java:4460) at java.awt.LightweightDispatcher.retargetMouseEvent(Container.java:4574) at java.awt.LightweightDispatcher.processMouseEvent(Container.java:4238) at java.awt.LightweightDispatcher.dispatchEvent(Container.java:4168) at java.awt.Container.dispatchEventImpl(Container.java:2085) at java.awt.Window.dispatchEventImpl(Window.java:2478) at java.awt.Component.dispatchEvent(Component.java:4460) at java.awt.EventQueue.dispatchEvent(EventQueue.java:599) at java.awt.EventDispatchThread.pumpOneEventForFilters(EventDispatchThread.java:269) at java.awt.EventDispatchThread.pumpEventsForFilter(EventDispatchThread.java:184) at java.awt.EventDispatchThread.pumpEventsForHierarchy(EventDispatchThread.java:174) at java.awt.EventDispatchThread.pumpEvents(EventDispatchThread.java:169) at java.awt.EventDispatchThread.pumpEvents(EventDispatchThread.java:161) at java.awt.EventDispatchThread.run(EventDispatchThread.java:122) Any idea how to solve this?

    Read the article

  • java jama array problem

    - by agazerboy
    Hi All, I asked a question before but duffymo said it is not clear so i am going to post it again here. I am using Jama api for SVD calculation. I know very well about jama and SVD. Jama does not work if your column are more than rows. I have this situation. What should I do?? any help? I can't transpose the matrix too as it can produce wrong results. Thanks. P.S: I am calculating LSI with the help of jama. I am going like column(docs) and rows ( terms )

    Read the article

  • ZFS - Impact of L2ARC cache device failure (Nexenta)

    - by ewwhite
    I have an HP ProLiant DL380 G7 server running as a NexentaStor storage unit. The server has 36GB RAM, 2 LSI 9211-8i SAS controllers (no SAS expanders), 2 SAS system drives, 12 SAS data drives, a hot-spare disk, an Intel X25-M L2ARC cache and a DDRdrive PCI ZIL accelerator. This system serves NFS to multiple VMWare hosts. I also have about 90-100GB of deduplicated data on the array. I've had two incidents where performance tanked suddenly, leaving the VM guests and Nexenta SSH/Web consoles inaccessible and requiring a full reboot of the array to restore functionality. In both cases, it was the Intel X-25M L2ARC SSD that failed or was "offlined". NexentaStor failed to alert me on the cache failure, however the general ZFS FMA alert was visible on the (unresponsive) console screen. The zpool status output showed: pool: vol1 state: ONLINE scan: scrub repaired 0 in 0h57m with 0 errors on Sat May 21 05:57:27 2011 config: NAME STATE READ WRITE CKSUM vol1 ONLINE 0 0 0 mirror-0 ONLINE 0 0 0 c8t5000C50031B94409d0 ONLINE 0 0 0 c9t5000C50031BBFE25d0 ONLINE 0 0 0 mirror-1 ONLINE 0 0 0 c10t5000C50031D158FDd0 ONLINE 0 0 0 c11t5000C5002C823045d0 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 c12t5000C50031D91AD1d0 ONLINE 0 0 0 c2t5000C50031D911B9d0 ONLINE 0 0 0 mirror-3 ONLINE 0 0 0 c13t5000C50031BC293Dd0 ONLINE 0 0 0 c14t5000C50031BD208Dd0 ONLINE 0 0 0 mirror-4 ONLINE 0 0 0 c15t5000C50031BBF6F5d0 ONLINE 0 0 0 c16t5000C50031D8CFADd0 ONLINE 0 0 0 mirror-5 ONLINE 0 0 0 c17t5000C50031BC0E01d0 ONLINE 0 0 0 c18t5000C5002C7CCE41d0 ONLINE 0 0 0 logs c19t0d0 ONLINE 0 0 0 cache c6t5001517959467B45d0 FAULTED 2 542 0 too many errors spares c7t5000C50031CB43D9d0 AVAIL errors: No known data errors This did not trigger any alerts from within Nexenta. I was under the impression that an L2ARC failure would not impact the system. But in this case, it surely was the culprit. I've never seen any recommendations to RAID L2ARC. Removing the bad SSD entirely from the server got me back running, but I'm concerned about the impact of the device failure (and maybe the lack of notification from NexentaStor as well). Edit - What's the current best-choice SSD for L2ARC cache applications these days?

    Read the article

  • Linux machine can't find its tape drive

    - by Kyle Hodgson
    I have an older HP NetServer LPr with what is apparently a Symbios SCSI card connecting to a Quantum SuperLoader 3 that is DLT based. From time to time, we seem to lose the connection to the autoloader. It's usually due to flaky power, but not totally sure why; sometimes when this happens the Autoloader's LED's are orange and it needs to be power cycled. The annoying workaround currently is to reboot the machine. As it is our production VPN and DNS server in addition to being our backup server, this is less than optimal. In Debian (Sarge) is there not some command one can type to get the card to notice that it has the autoloader connected again? dcr1:/proc# grep -i symbios /proc/pci SCSI storage controller: LSI Logic / Symbios Logic 53c895 (rev 1). dcr1:/proc# uname -a Linux dcr1 2.4.27-3-686 #1 Tue Dec 5 21:03:54 UTC 2006 i686 GNU/Linux dcr1:/proc# mt status mt: /dev/tape: No such device dcr1:/proc# ls -l /dev/tape lrwxrwxrwx 1 root root 8 2007-02-07 16:01 /dev/tape -> /dev/st0 dcr1:/proc# That mt status command will show the actual st0 status when things are working correctly. The No such device message is usually the second clue that we need to reboot - the first clue is usually that the backups didn't run.

    Read the article

  • NFS high CPU usage

    - by user269836
    Hello, I have a very strange issue. I have next server: Intel(R) Xeon(TM) MP CPU 3.16GHz cat /proc/cpuinfo | grep proce | wc -l 8 free -m total used free shared buffers cached Mem: 28203 27606 596 0 10789 9714 -/+ buffers/cache: 7103 21100 Swap: 24695 0 24695 RAID card *-storage description: RAID bus controller product: MegaRAID vendor: LSI Logic / Symbios Logic physical id: 7 bus info: pci@0000:13:07.0 logical name: scsi2 version: 01 width: 32 bits clock: 66MHz capabilities: storage pm bus_master cap_list rom configuration: driver=megaraid latency=32 resources: irq:134 memory:d8ff0000-d8ffffff(prefetchable) memory:df600000-df60ffff(prefetchable) HDD: 10x148Gb SCSI U320 15k - RAID5 /dev/sdb1 807G 674G 93G 88% /storage /dev/sdb1 /storage ext4 defaults,usrjquota=aquota.user,grpjquota=aquota.group,jqfmt=vfsv0,noatime,nodiratime,noacl,errors=remount-ro 0 1 network cards ethtool -i eth0 driver: tg3 version: 3.116 firmware-version: 5704-v3.36, ASFIPMIc v2.36 bus-info: 0000:10:02.0 ethtool -i eth1 driver: tg3 version: 3.116 firmware-version: 5704-v3.36, ASFIPMIc v2.36 bus-info: 0000:10:02.0 ifconfig bond0 Link encap:Ethernet HWaddr 00:0f:1f:ff:d6:4d inet addr:192.168.15.71 Bcast:192.168.15.255 Mask:255.255.255.0 inet6 addr: fe80::20f:1fff:feff:d64d/64 Scope:Link UP BROADCAST RUNNING MASTER MULTICAST MTU:1500 Metric:1 RX packets:1062818202 errors:0 dropped:3918 overruns:0 frame:0 TX packets:1041317321 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:10000 RX bytes:258867684559 (241.0 GiB) TX bytes:396569192650 (369.3 GiB) this server running only nfs-kernel-server uname -a Linux nas2-backup 2.6.32-5-amd64 #1 SMP Sun Sep 23 10:07:46 UTC 2012 x86_64 GNU/Linux Debian 6. What do I have, once per day or two, LA goes up, it can be reached around LA: 40 but if I do: nfs-kernel-server restart. Every thing is OK. But on the next day or a little bit later, LA goes up again. Servers are connected to d-link dgs 1016d with 24 GBits ports. I have tried everything to find out what the problem is. Why it's happening, but still I can not resolve this issue. Any ideas on what is happening here?

    Read the article

  • UAC being turned off once a day on Windows 7

    - by Mehper C. Palavuzlar
    I have strange problem on my HP laptop. This began to happen recently. Whenever I start my machine, Windows 7 Action Center displays the following warning: You need to restart your computer for UAC to be turned off. Actually, this does not happen if it happened once on a specific day. For example, when I start the machine in the morning, it shows up; but it never shows up in the subsequent restarts within that day. On the next day, the same thing happens again. I never disable UAC, but obviously some rootkit or virus causes this. As soon as I get this warning, I head for the UAC settings, and re-enable UAC to dismiss this warning. This is a bothersome situation as I can't fix it. First, I have run a full scan on the computer for any probable virus and malware/rootkit activity, but TrendMicro OfficeScan said that no viruses have been found. I went to an old Restore Point using Windows System Restore, but the problem was not solved. What I have tried so far (which couldn't find the rootkit): TrendMicro OfficeScan Antivirus AVAST Malwarebytes' Anti-malware Ad-Aware Vipre Antivirus GMER TDSSKiller (Kaspersky Labs) HiJackThis RegRuns UnHackMe SuperAntiSpyware Portable Tizer Rootkit Razor (*) Sophos Anti-Rootkit SpyHunter 4 There are no other strange activities on the machine. Everything works fine except this bizarre incident. What could be the name of this annoying rootkit? How can I detect and remove it? EDIT: Below is the log file generated by HijackThis: Logfile of Trend Micro HijackThis v2.0.4 Scan saved at 13:07:04, on 17.01.2011 Platform: Windows 7 (WinNT 6.00.3504) MSIE: Internet Explorer v8.00 (8.00.7600.16700) Boot mode: Normal Running processes: C:\Windows\system32\taskhost.exe C:\Windows\system32\Dwm.exe C:\Windows\Explorer.EXE C:\Program Files\CheckPoint\SecuRemote\bin\SR_GUI.Exe C:\Windows\System32\igfxtray.exe C:\Windows\System32\hkcmd.exe C:\Windows\system32\igfxsrvc.exe C:\Windows\System32\igfxpers.exe C:\Program Files\Hewlett-Packard\HP Wireless Assistant\HPWAMain.exe C:\Program Files\Synaptics\SynTP\SynTPEnh.exe C:\Program Files\Hewlett-Packard\HP Quick Launch Buttons\QLBCTRL.exe C:\Program Files\Analog Devices\Core\smax4pnp.exe C:\Program Files\Hewlett-Packard\HP Quick Launch Buttons\VolCtrl.exe C:\Program Files\LightningFAX\LFclient\lfsndmng.exe C:\Program Files\Common Files\Java\Java Update\jusched.exe C:\Program Files\Microsoft Office Communicator\communicator.exe C:\Program Files\Iron Mountain\Connected BackupPC\Agent.exe C:\Program Files\Trend Micro\OfficeScan Client\PccNTMon.exe C:\Program Files\Microsoft LifeCam\LifeExp.exe C:\Program Files\Hewlett-Packard\Shared\HpqToaster.exe C:\Program Files\Windows Sidebar\sidebar.exe C:\Program Files\mimio\mimio Studio\system\aps_tablet\atwtusb.exe C:\Program Files\Microsoft Office\Office12\OUTLOOK.EXE C:\Program Files\Babylon\Babylon-Pro\Babylon.exe C:\Program Files\Mozilla Firefox\firefox.exe C:\Users\userx\Desktop\HijackThis.exe R1 - HKCU\Software\Microsoft\Internet Explorer\Main,Search Page = http://go.microsoft.com/fwlink/?LinkId=54896 R0 - HKCU\Software\Microsoft\Internet Explorer\Main,Start Page = about:blank R1 - HKLM\Software\Microsoft\Internet Explorer\Main,Default_Page_URL = http://go.microsoft.com/fwlink/?LinkId=69157 R1 - HKLM\Software\Microsoft\Internet Explorer\Main,Default_Search_URL = http://go.microsoft.com/fwlink/?LinkId=54896 R1 - HKLM\Software\Microsoft\Internet Explorer\Main,Search Page = http://go.microsoft.com/fwlink/?LinkId=54896 R0 - HKLM\Software\Microsoft\Internet Explorer\Main,Start Page = http://go.microsoft.com/fwlink/?LinkId=69157 R0 - HKLM\Software\Microsoft\Internet Explorer\Search,SearchAssistant = R0 - HKLM\Software\Microsoft\Internet Explorer\Search,CustomizeSearch = R1 - HKCU\Software\Microsoft\Windows\CurrentVersion\Internet Settings,AutoConfigURL = http://www.yaysat.com.tr/proxy/proxy.pac R0 - HKCU\Software\Microsoft\Internet Explorer\Toolbar,LinksFolderName = O2 - BHO: AcroIEHelperStub - {18DF081C-E8AD-4283-A596-FA578C2EBDC3} - C:\Program Files\Common Files\Adobe\Acrobat\ActiveX\AcroIEHelperShim.dll O2 - BHO: Babylon IE plugin - {9CFACCB6-2F3F-4177-94EA-0D2B72D384C1} - C:\Program Files\Babylon\Babylon-Pro\Utils\BabylonIEPI.dll O2 - BHO: Java(tm) Plug-In 2 SSV Helper - {DBC80044-A445-435b-BC74-9C25C1C588A9} - C:\Program Files\Java\jre6\bin\jp2ssv.dll O4 - HKLM\..\Run: [IgfxTray] C:\Windows\system32\igfxtray.exe O4 - HKLM\..\Run: [HotKeysCmds] C:\Windows\system32\hkcmd.exe O4 - HKLM\..\Run: [Persistence] C:\Windows\system32\igfxpers.exe O4 - HKLM\..\Run: [hpWirelessAssistant] C:\Program Files\Hewlett-Packard\HP Wireless Assistant\HPWAMain.exe O4 - HKLM\..\Run: [SynTPEnh] C:\Program Files\Synaptics\SynTP\SynTPEnh.exe O4 - HKLM\..\Run: [QlbCtrl.exe] C:\Program Files\Hewlett-Packard\HP Quick Launch Buttons\QlbCtrl.exe /Start O4 - HKLM\..\Run: [SoundMAXPnP] C:\Program Files\Analog Devices\Core\smax4pnp.exe O4 - HKLM\..\Run: [Adobe Reader Speed Launcher] "C:\Program Files\Adobe\Reader 9.0\Reader\Reader_sl.exe" O4 - HKLM\..\Run: [Adobe ARM] "C:\Program Files\Common Files\Adobe\ARM\1.0\AdobeARM.exe" O4 - HKLM\..\Run: [lfsndmng] C:\Program Files\LightningFAX\LFclient\LFSNDMNG.EXE O4 - HKLM\..\Run: [SunJavaUpdateSched] "C:\Program Files\Common Files\Java\Java Update\jusched.exe" O4 - HKLM\..\Run: [Communicator] "C:\Program Files\Microsoft Office Communicator\communicator.exe" /fromrunkey O4 - HKLM\..\Run: [AgentUiRunKey] "C:\Program Files\Iron Mountain\Connected BackupPC\Agent.exe" -ni -sss -e http://localhost:16386/ O4 - HKLM\..\Run: [OfficeScanNT Monitor] "C:\Program Files\Trend Micro\OfficeScan Client\pccntmon.exe" -HideWindow O4 - HKLM\..\Run: [Babylon Client] C:\Program Files\Babylon\Babylon-Pro\Babylon.exe -AutoStart O4 - HKLM\..\Run: [LifeCam] "C:\Program Files\Microsoft LifeCam\LifeExp.exe" O4 - HKCU\..\Run: [Sidebar] C:\Program Files\Windows Sidebar\sidebar.exe /autoRun O4 - Global Startup: mimio Studio.lnk = C:\Program Files\mimio\mimio Studio\mimiosys.exe O8 - Extra context menu item: Microsoft Excel'e &Ver - res://C:\PROGRA~1\MICROS~1\Office12\EXCEL.EXE/3000 O8 - Extra context menu item: Translate this web page with Babylon - res://C:\Program Files\Babylon\Babylon-Pro\Utils\BabylonIEPI.dll/ActionTU.htm O8 - Extra context menu item: Translate with Babylon - res://C:\Program Files\Babylon\Babylon-Pro\Utils\BabylonIEPI.dll/Action.htm O9 - Extra button: Research - {92780B25-18CC-41C8-B9BE-3C9C571A8263} - C:\PROGRA~1\MICROS~1\Office12\REFIEBAR.DLL O9 - Extra button: Translate this web page with Babylon - {F72841F0-4EF1-4df5-BCE5-B3AC8ACF5478} - C:\Program Files\Babylon\Babylon-Pro\Utils\BabylonIEPI.dll O9 - Extra 'Tools' menuitem: Translate this web page with Babylon - {F72841F0-4EF1-4df5-BCE5-B3AC8ACF5478} - C:\Program Files\Babylon\Babylon-Pro\Utils\BabylonIEPI.dll O16 - DPF: {00134F72-5284-44F7-95A8-52A619F70751} (ObjWinNTCheck Class) - https://172.20.12.103:4343/officescan/console/html/ClientInstall/WinNTChk.cab O16 - DPF: {08D75BC1-D2B5-11D1-88FC-0080C859833B} (OfficeScan Corp Edition Web-Deployment SetupCtrl Class) - https://172.20.12.103:4343/officescan/console/html/ClientInstall/setup.cab O17 - HKLM\System\CCS\Services\Tcpip\Parameters: Domain = yaysat.com O17 - HKLM\Software\..\Telephony: DomainName = yaysat.com O17 - HKLM\System\CS1\Services\Tcpip\Parameters: Domain = yaysat.com O17 - HKLM\System\CS2\Services\Tcpip\Parameters: Domain = yaysat.com O18 - Protocol: qcom - {B8DBD265-42C3-43E6-B439-E968C71984C6} - C:\Program Files\Common Files\Quest Shared\CodeXpert\qcom.dll O22 - SharedTaskScheduler: FencesShellExt - {1984DD45-52CF-49cd-AB77-18F378FEA264} - C:\Program Files\Stardock\Fences\FencesMenu.dll O23 - Service: Andrea ADI Filters Service (AEADIFilters) - Andrea Electronics Corporation - C:\Windows\system32\AEADISRV.EXE O23 - Service: AgentService - Iron Mountain Incorporated - C:\Program Files\Iron Mountain\Connected BackupPC\AgentService.exe O23 - Service: Agere Modem Call Progress Audio (AgereModemAudio) - LSI Corporation - C:\Program Files\LSI SoftModem\agrsmsvc.exe O23 - Service: BMFMySQL - Unknown owner - C:\Program Files\Quest Software\Benchmark Factory for Databases\Repository\MySQL\bin\mysqld-max-nt.exe O23 - Service: Com4QLBEx - Hewlett-Packard Development Company, L.P. - C:\Program Files\Hewlett-Packard\HP Quick Launch Buttons\Com4QLBEx.exe O23 - Service: hpqwmiex - Hewlett-Packard Development Company, L.P. - C:\Program Files\Hewlett-Packard\Shared\hpqwmiex.exe O23 - Service: OfficeScanNT RealTime Scan (ntrtscan) - Trend Micro Inc. - C:\Program Files\Trend Micro\OfficeScan Client\ntrtscan.exe O23 - Service: SMS Task Sequence Agent (smstsmgr) - Unknown owner - C:\Windows\system32\CCM\TSManager.exe O23 - Service: Check Point VPN-1 Securemote service (SR_Service) - Check Point Software Technologies - C:\Program Files\CheckPoint\SecuRemote\bin\SR_Service.exe O23 - Service: Check Point VPN-1 Securemote watchdog (SR_Watchdog) - Check Point Software Technologies - C:\Program Files\CheckPoint\SecuRemote\bin\SR_Watchdog.exe O23 - Service: Trend Micro Unauthorized Change Prevention Service (TMBMServer) - Trend Micro Inc. - C:\Program Files\Trend Micro\OfficeScan Client\..\BM\TMBMSRV.exe O23 - Service: OfficeScan NT Listener (tmlisten) - Trend Micro Inc. - C:\Program Files\Trend Micro\OfficeScan Client\tmlisten.exe O23 - Service: OfficeScan NT Proxy Service (TmProxy) - Trend Micro Inc. - C:\Program Files\Trend Micro\OfficeScan Client\TmProxy.exe O23 - Service: VNC Server Version 4 (WinVNC4) - RealVNC Ltd. - C:\Program Files\RealVNC\VNC4\WinVNC4.exe -- End of file - 8204 bytes As suggested in this very similar question, I have run full scans (+boot time scans) with RegRun and UnHackMe, but they also did not find anything. I have carefully examined all entries in the Event Viewer, but there's nothing wrong. Now I know that there is a hidden trojan (rootkit) on my machine which seems to disguise itself quite successfully. Note that I don't have the chance to remove the HDD, or reinstall the OS as this is a work machine subjected to certain IT policies on a company domain. Despite all my attempts, the problem still remains. I strictly need a to-the-point method or a pukka rootkit remover to remove whatever it is. I don't want to monkey with the system settings, i.e. disabling auto runs one by one, messing the registry, etc. EDIT 2: I have found an article which is closely related to my trouble: Malware can turn off UAC in Windows 7; “By design” says Microsoft. Special thanks(!) to Microsoft. In the article, a VBScript code is given to disable UAC automatically: '// 1337H4x Written by _____________ '// (12 year old) Set WshShell = WScript.CreateObject("WScript.Shell") '// Toggle Start menu WshShell.SendKeys("^{ESC}") WScript.Sleep(500) '// Search for UAC applet WshShell.SendKeys("change uac") WScript.Sleep(2000) '// Open the applet (assuming second result) WshShell.SendKeys("{DOWN}") WshShell.SendKeys("{DOWN}") WshShell.SendKeys("{ENTER}") WScript.Sleep(2000) '// Set UAC level to lowest (assuming out-of-box Default setting) WshShell.SendKeys("{TAB}") WshShell.SendKeys("{DOWN}") WshShell.SendKeys("{DOWN}") WshShell.SendKeys("{DOWN}") '// Save our changes WshShell.SendKeys("{TAB}") WshShell.SendKeys("{ENTER}") '// TODO: Add code to handle installation of rebound '// process to continue exploitation, i.e. place something '// evil in Startup folder '// Reboot the system '// WshShell.Run "shutdown /r /f" Unfortunately, that doesn't tell me how I can get rid of this malicious code running on my system. EDIT 3: Last night, I left the laptop open because of a running SQL task. When I came in the morning, I saw that UAC was turned off. So, I suspect that the problem is not related to startup. It is happening once a day for sure no matter if the machine is rebooted.

    Read the article

  • Is current SATA 6 gb/s equipment simply unreliable?

    - by korkman
    I have a 45-disk array of Seagate Barracuda 3 TB ST3000DM001 (yes these are desktop drives I'm aware of that) in a Supermicro sc847 JBOD, connected via LSI 9285. I have found a solution for the problem description below by reducing speed via MegaCli -PhySetLinkSpeed -phy0 2 -a0; for i in $(seq 48); do MegaCli -PhySetLinkSpeed -phy${i} 2 -a0; done and rebooting. The question remains: Is this typical for current 6 gb/s equipment? Is this the sad state of SATA storage? Or is some of my equipment (the sff-8088 cables come to mind) bad? The Problem was: Synchronizing HW RAID-6, disks kept offlining. Fetching SMART values reveiled that those which offlined did not increase powered-on hours anymore. That is, their firmware (CC4C) seems to crash. Digging into the matter by switching to Software RAID-6, with the disks passed-through, I got tons of kernel messages scattered across all disks, with 6 gb/s: sd 0:0:9:0: [sdb] Sense Key : No Sense [current] Info fld=0x0 sd 0:0:9:0: [sdb] Add. Sense: No additional sense information And finally, when a disk offlines: megasas: [ 5]waiting for 160 commands to complete ... megasas: [35]waiting for 159 commands to complete ... megasas: [155]waiting for 156 commands to complete ... megaraid_sas: pending commands remain after waiting, will reset adapter. Ugly controller reset here, then minutes later: megaraid_sas: Reset successful. sd 0:0:28:0: Device offlined - not ready after error recovery ... sd 0:0:28:0: [sdu] Unhandled error code sd 0:0:28:0: [sdu] Result: hostbyte=DID_ERROR driverbyte=DRIVER_OK sd 0:0:28:0: [sdu] CDB: Read(10): 28 00 23 21 2f 40 00 00 70 00 sd 0:0:28:0: [sdu] killing request Reduced speed to 3 gb/s like written above, all problems vanished.

    Read the article

  • Server nearly unusable when doing disk writes

    - by Wikser
    My question closely relates to my last question here on serverfault. I was copying about 5GB from a 10 year old desktop computer to the server. The copy was done in Windows Explorer. In this situation I would assume the server to be bored by the dataflow. But as usual with this server, it really slowed down. At least I could work with the remote session, even there was some serious latency. The copy took its time (20min?). In this time I went to a colleague and he tried to log in in the same server via remote desktop (for some other reason). It took about a minute to get to the login screen, a minute to open the control panel, a minute to open the performance monitor, ... Icons were loading maybe one per second. We saw the following (from memory): CPU: 2% Avg. Queue Length: 50 Pages/sec: 115 (?) There was no other considerable activity on the server. The server seldom serves some ASP.NET pages, which became also very slow in this time. The relevant configuration is as follows: Windows 2003 SEAGATE ST3500631NS (7200 rpm, 500 GB) LSI MegaRAID based RAID 5 4 disks, 1 hot spare Write Through No read-ahead Direct Cache Mode Harddisk-Cache-Mode: off Is this normal behaviour for such a configuration? What measurements could give further clues? Is it reasonable to reduce the priority of such copy I/O and favour other processes like the remote desktop? How would you do that? Many thanks!

    Read the article

  • linux hardware raid 10 / lvm / virtual machine partition alignment and filesystem optimization

    - by Jason Ward
    I've been reading everything I can find about partition alignment and filesystem optimization (ext4 and xfs) but still don't know enough to be confident in setting up my current configuration. My remaining confusion comes from the LVM layer and if I should use raid parameters on the filesystem in guest os'es. My main questions are: When I use 'pvcreate --dataalignment' do I use the stripe-width as calculated for a filesystem on RAID (128kB for ext4 in my situation), the Stripe size of the RAID set (256kB), something else altogether, or do I not need this? When I create ext2/3/4 or xfs filesystems in guests on the Logical Volumes, should I add the settings for the underlying RAID (e.g. mkfs.ext4 -b 4096 -E stride=64,stripe-width=128)? Does anyone see any glaring errors in my set up below? I'm running some benchmarks now but haven't done enough to start comparing results. I have four drives in RAID 10 on a 3ware 9750-4i controller (more details on the settings below) giving me a 6.0TB device at /dev/sda. Here is my partition table: Model: LSI 9750-4i DISK (scsi) Disk /dev/sda: 5722024MiB Sector size (logical/physical): 512B/512B Partition Table: gpt Number Start End Size File system Name Flags 1 1.00MiB 257MiB 256MiB ext4 BOOTPART boot 2 257MiB 4353MiB 4096MiB linux-swap(v1) 3 4353MiB 266497MiB 262144MiB ext4 4 266497MiB 4460801MiB 4194304MiB Partition 1 is to be the /boot partition for my xen host. Partition 2 is swap. Partition 3 is to be the root (/) for my xen host. Partition 4 is to be (the only) physical volume to be used by LVM (for those who are counting, I left about 1.2TB unallocated for now) For my Xen guests, I usually create a Logical Volume of the needed size and present it to the guests for them to partition as needed. I know there are other ways of handling that but this method works best for my situation. Here's the hardware of interest on my CentOS 6.3 Xen Host: 4x Seagate Barracuda 3TB ST3000DM001 Drives (sector size: 512 logical/4096 physical) 3ware 9750-4i w/BBU (sector size reported: 512 logical/512 physical) All four drives make up a RAID 10 array. Stripe: 256kB Write Cache enabled Read Cache: intelligent StoreSave: Balance Thanks!

    Read the article

  • Which is the fastest way to move 1Petabyte from one storage to a new one?

    - by marc.riera
    First of all, thanks for reading, and sorry for asking something related to my job. I understand that this is something that I should solve by myself but as you will see its something a bit difficult. A small description: Now Storage = 1PB using DDN S2A9900 storage for the OSTs, 4 OSS , 10 GigE network. (lustre 1.6) 100 compute nodes with 2x Infiniband 1 infiniband switch with 36 ports After Storage = Previous storage + another 1PB using DDN S2A 990 or LSI E5400 (still to decide) (lustre 2.0) 8 OSS , 10GigE network 100 compute nodes with 2x Infiniband Previous experience: transfered 120 TB in less than 3 days using following command: tar -C /old --record-size 2048 -b 2048 -cf - dir | tar -C /new --record-size 2048 -b 2048 -xvf - 2>&1 | tee /tmp/dir.log So , big problem here, using big mathematical equations I conclude that we are going to need 1 month to transfer the data from one side to the new one. During this time the researchers will need to step back, and I'm personally not happy with this. I'm telling you that we have infiniband connections because I think that may be there is a chance to use it to transfer the data using 18 compute nodes (18 * 2 IB = 36 ports) to transfer the data from one storage to the other. I'm trying to figure out if the IB switch will handle all the traffic but in case it just burn up will go faster than using 10GigE. Also, having lustre 1.6 and 2.0 agents on same server works quite well, with this there is no need to go by 1.8 to upgrade the metadata servers with two steps. Any ideas? Many thanks Note 1: Zoredache, we can divide it in two blocks (A)600Tb and (B)400Tb. The idea is to move (A) to new storage which is lustre2.0 formated, then format where (A) was with lustre2.0 and move (B) to this lustre2.0 block and extend with the space where (B) was. This way we will end with (A) and (B) on separate filesystems, with 1PB each.

    Read the article

  • SSD seems dead after wakeup from Windows Sleep, BIOS stalls but doesn't find it anymore

    - by Abel
    The morning, the following scary scenario happened: I woke up my Windows system Typed in my username and got an error (something like "could not load security xxx", but unsure of exact wording) System auto-restarted after cliking OK It didn't boot up anymore to the SSD with Windows 7 OS (I have another disk I can boot to, but that doesn't see the disk either). Obviously, this happened right after I instantiated a backup procedure, which hasn't succeeded either. The BIOS can't find the drive when I connect to SATA. And it can't find the drive when I connect it to SAS. I have a Dell Workstation T7400, most recent BIOS (version A06), version of SAS Host Bus Adapter BIOS (HBA) is MPTBIOS 6.14.10.00 (2007.09.29) from LSI Logic Corp. Other findings: When connecting to SATA, the DELL Logo screen stays really long (5 minutes) and then at the end of POST it says that a drive is not found When connecting to SAS, the SAS HBA initializing phase takes long (2 minutes, against normally 15 seconds) When running Dell Diagnostics, it doesn't finish and gives the error Exception occurred in module MPCACHE.MDM file "IOAPICSP.ASM" line 1645. I contacted Dell. On their advice I tried different slots and different cables to no avail. I use an APIC battery power, spikes in the power are thus unlikely. My conclusion so far: the disk is dead. I need this disk very badly because it contains the last few days of important development of which not all code was checked in the moment this happened. Are there any ways to recover dead SSD drives? The drive is a new X25-M G2 160GB model SSDSA2M160G2GC 2.5" in an extension bay and has been running without issues for 3 months on SAS.

    Read the article

  • Optimizing Disk I/O & RAID on Windows SQL Server 2005

    - by David
    I've been monitoring our SQL server for a while, and have noticed that I/O hits 100% every so often using Task Manager and Perfmon. I have normally been able to correlate this spike with SUSPENDED processes in SQL Server Management when I execute "exec sp_who2". The RAID controller is controlled by LSI MegaRAID Storage Manager. We have the following setup: System Drive (Windows) on RAID 1 with two 280GB drives SQL is on a RAID 10 (2 mirroed drives of 280GB in two different spans) This is a database that is hammered during the day, but is pretty inactive at night. The DB size is currently about 13GB, and is used by approximately 200 (and growing) users a day. I have a couple of ideas I'm toying around with: Checking for Indexes & reindexing some tables Adding an additional RAID 1 (with 2 new, smaller, HDs) and moving the SQL's Log Data File (LDF) onto the new RAID. For #2, my question is this: Would we really be increasing disk performance (IO) by moving data off of the RAID 10 onto a RAID 1? RAID 10 obviously has better performance than RAID 1. Furthermore, SQL must write to the transaction logs before writing to the database. But on the flip side, we'll be reducing both the size of the disks as well as the amount of data written to the RAID 10, which is where all of the "meat" is - thereby increasing that RAID's performance for read requests. Is there any way to find out what our current limiting factor is? (The drives vs. the RAID Controller)? If the limiting factor is the drives, then maybe adding the additional RAID 1 makes sense. But if the limiting factor is the Controller itself, then I think we're approaching this thing wrong. Finally, are we just wasting our time? Should we instead be focusing our efforts towards #1 (reindexing tables, reducing network latency where possible, etc...)?

    Read the article

  • Linux - real-world hardware RAID controller tuning (scsi and cciss)

    - by ewwhite
    Most of the Linux systems I manage feature hardware RAID controllers (mostly HP Smart Array). They're all running RHEL or CentOS. I'm looking for real-world tunables to help optimize performance for setups that incorporate hardware RAID controllers with SAS disks (Smart Array, Perc, LSI, etc.) and battery-backed or flash-backed cache. Assume RAID 1+0 and multiple spindles (4+ disks). I spend a considerable amount of time tuning Linux network settings for low-latency and financial trading applications. But many of those options are well-documented (changing send/receive buffers, modifying TCP window settings, etc.). What are engineers doing on the storage side? Historically, I've made changes to the I/O scheduling elevator, recently opting for the deadline and noop schedulers to improve performance within my applications. As RHEL versions have progressed, I've also noticed that the compiled-in defaults for SCSI and CCISS block devices have changed as well. This has had an impact on the recommended storage subsystem settings over time. However, it's been awhile since I've seen any clear recommendations. And I know that the OS defaults aren't optimal. For example, it seems that the default read-ahead buffer of 128kb is extremely small for a deployment on server-class hardware. The following articles explore the performance impact of changing read-ahead cache and nr_requests values on the block queues. http://zackreed.me/articles/54-hp-smart-array-p410-controller-tuning http://www.overclock.net/t/515068/tuning-a-hp-smart-array-p400-with-linux-why-tuning-really-matters http://yoshinorimatsunobu.blogspot.com/2009/04/linux-io-scheduler-queue-size-and.html For example, these are suggested changes for an HP Smart Array RAID controller: echo "noop" > /sys/block/cciss\!c0d0/queue/scheduler blockdev --setra 65536 /dev/cciss/c0d0 echo 512 > /sys/block/cciss\!c0d0/queue/nr_requests echo 2048 > /sys/block/cciss\!c0d0/queue/read_ahead_kb What else can be reliably tuned to improve storage performance? I'm specifically looking for sysctl and sysfs options in production scenarios.

    Read the article

  • ssd firmware, linux: updating large batch of drives

    - by wryfi
    I was recently hit with a fatal firmware bug that affected dozens of Crucial SSDs deployed in my datacenter. Many of the affected machines use LSI or other proprietary SAS controllers, which Crucial's bootable ISO does not recognize. None of the affected machines has a Windows license. The story is roughly similar for other SSD mfrs, including Samsung and Intel. To resolve this issue, I was forced to stop each machine, remove the affected SSD, remove the SSD from its hotswap caddy, install it temporarily into my ThinkPad, flash the firmware, reverse, rinse, repeat. It took the better part of a day to get through all the affected devices. I am looking for hardware, software, and/or purchasing strategies to ease this pain, as SSD firmware bugs seem inevitable, and our SSD footprint is growing. My first thought is to get a laptop with eSATA and one of these cables (http://www.newegg.com/Product/Product.aspx?Item=N82E16812311004). That should at least make it so I don't have to remove the drives from their caddies. Surely others have run into this. Any novel solutions?

    Read the article