  • Configuring https access on HP A5120 Switch

    - by GerryEgan
    I am trying to configure HTTPS management on a HP a5120 switch running Version 5.20.99, Release 2215 and not having much luck. I have followed the manual by creating an SSL policy first and then enabling the HTTPS server with the SSL policy: ssl server-policy sslpol ip https ssl-server-policy sslpol ip https enable When I try and log onto the switch with Google Chrome I get the following error: Error 107 (net::ERR_SSL_PROTOCOL_ERROR): SSL protocol error. When I look this up I have found references to errors due to TLS being used in SSL. I can find no way to specify the SSL version in the server policy. The manual has a configuration example that uses MSCEP to retrieve a certificate but in Windows 2008 R2 that feature is only available in Enterprise and Datacentre editions which I don't have. I have SSH configured and it is using a locally generated certificate so I'm not sure if I can use that but I'd like to if possible. Has anybody been able to setup HTTPS management on HP A series switches without MSCEP? Any and all help appreciated! here is a copy of my config with the interfaces removed: version 5.20.99, Release 2215 # sysname MYSYSNAME # irf domain 10 irf mac-address persistent timer irf auto-update enable undo irf link-delay # domain default enable system # telnet server enable # vlan 1 # vlan 100 description Management # radius scheme system primary authentication 127.0.0.1 1645 primary accounting 127.0.0.1 1646 user-name-format without-domain # domain system access-limit disable state active idle-cut disable self-service-url disable # user-group system group-attribute allow-guest # local-user admin password cipher authorization-attribute level 3 service-type ssh telnet terminal service-type web # stp enable # ssl server-policy sslpol pki-domain MYDOMAIN # interface NULL0 # interface Vlan-interface199 ip address 192.168.199.140 255.255.255.0 # interface GigabitEthernet1/0/1 poe enable stp edged-port enable # interface Ten-GigabitEthernet2/1/2 # dhcp-snooping # ntp-service unicast-server 192.168.1.71 # ssh server enable # ip https ssl-server-policy sslpol ip https enable # load xml-configuration # user-interface aux 0 1 user-interface vty 0 15 authentication-mode scheme

    Read the article

  • VLAN Through Switch Doesn't Work

    - by vcsjones
    I have the following scenario: I have a Cisco Aironet 1040 access point. I have it configured with two SSIDs, each going to a different VLAN. So: SSID internal : VLAN 90 SSID guest : VLAN 70 On the router side, I have a Cisco RV220W (with the radios now turned off) and have setup VLANs with like VLAN IDs. VLAN 90 : 192.168.90.0/24 VLAN 70 : 192.168.70.0/24 As far as DHCP is concerned, each VLAN has a "DHCP Server" in the router's configuration: So with the access point connected directly to the router, everything works great. I connect to the internal network, and I get a 192.168.90.x address, and the guest network gets a 70.xxx address. Next I introduced a Cisco SG200-50 PoE switch between the router and the access point. The port is configured as a trunk port, so the VLAN tags should go right through the switch back to the router. However, when something is connected to the access point, nothing works. It isn't able to get an IP address, and manually assigning one doesn't seem to let any traffic route. Given that the access point works correctly when connected to the router directly, I believe the switch is misconfigured. What am I missing here? What can I use to better diagnose what the problem might be? It's small business equipment, so CLI access is not available. Below are screenshots of the switch's config. The access point is connected to GE2.

    Read the article

  • DD-WRT Acces Point as a Router

    - by Dzh
    Following suggestion to this question asked on Network Engineering, I am asking the question here. this is an extension to my previous question (I think it was deleted), where I was claiming that DDWRT was disabling it's DHCP server once connected to the network. I was wrong, as it now seems that it is bridging itself with another parallel connected wireless router. I have two Draytek 2820 and one Netgear WG602v3 with latest DDWRT. Lets call one wired-Draytek and it has wireless disabled. The other one, let's call it wireless-Draytek, is connected to wired-Draytek and has wireless with MAC filtering enabled. Once I connect Netgear to the wired-Draytek, the client that connects to Netgear, will be assigned with IP address from the wireless-Draytek. If the MAC address is not on the wireles-Draytek, the client is unable to obtain IP address and has no connectivity at all, even with manually assigned static IP configuration. To illustrate further, this is how network is set up: wired-Draytek ---------- wireless-Draytek \_________ Netgear What I wish to have, is that Netgear issues IP addresses from it's own IP pool and ignores the MAC filtering rules from wireless-Draytek. This is kind of puzzling how this they are bridging (if they are) themselves automatically. Thanks. UPDATE: It's not a home network. I gave you a bit simplified set-up. If there is a better site on Stack Exchange to ask this, please let me know. The Drayteks are running stock firmware, it's only Netgear that I've flashed to get more stability. In addition to these routers, I have also three 3COM Baseline switch 2824, and another Draytek router with Prosafe FS752TP PoE switch dedicated for VoIP phones. Wired-Draytek has IP 10.0.0.1, DHCP disabled as there is AD DC which is issuing IP addresses. Wireless-Draytek has IP 1.1.1.1 and DHCP enabled. Netgear has default - 192.168.1.1. As per suggestion, the specific question is - how do I isolate these two wireless routers?

    Read the article

  • What are my options in replacing the noisy fan in my Linksys Cisco SRW2008P managed GigE switch?

    - by Fred Sobotka
    My first managed GigE switch, the Linksys SRW2008, was a dream, until it started randomly chattering on various ports. That started while I was on the road all the time, which made it take forever to diagnose, but that's a different problem. When I finally determined that the switch was bad, it was still covered by warranty by Linksys/Cisco, so I opened an RMA ticket and returned it. Unfortunately, Linksys/Cisco "upgraded" my replacement switch to a SRW2008P, which has Power over Ethernet features I never planned on using. That by itself wasn't so bad, but it's my guess that the inclusion of PoE functions in this model required a tiny, super-loud internal fan to keep everything cool. This wasn't something I wanted or asked for, but, now that I am stuck with it, I am investigating options for replacing that little internal fan with something far quieter. For example, if I attach a larger fan to the outsite of the chassis, I think it could push enough air to replace the stock fan that is currently there. Any advice on carrying this out? I have no interest in melting my switch due to insufficient ventilation.

    Read the article

  • Cisco VoIP stuck as Unregistered?

    - by Shifty
    Question: Why is one VoIP stuck as Unregistered? Background: We have a Cisco UC540 Small Business switch/router/voip combo. This phone was working until I powered everything down to install a larger UPS unit. The phone originally had a status of "Deceased". I removed the registration and tried to add it again. Now it just sits as "Unregistered". I even tried giving it another extension. I am stuck using the Cisco Communication Assistant since this is small business hardware. There is very limited CLI access. Also, from what I heard, if you access the CLI with out cisco permission, you will void any warranty. The phone in question is a Cisco SPA501G. It is connected to a SG300-28P. There are 5 other phones on this switch working just fine. I have tried other ports with no luck. Both the link and PoE lights are lit up. Any ideas?

    Read the article

  • Intermittent internet access on a flat network - Router is connected

    - by Naveed
    I’m looking for some help with network settings. I’ve just started a new job (non-IT!) and we have problems with our office network. I’m the most IT literate in the organisation (15 permanent employees) and so have been dealing with IT issues. Our main bit of software is web-based so we need constant web access but it sometimes goes down for between 20 minutes and 3 hours despite everything seemingly working fine. It’s a flat network with wireless APs, BT Business Broadband 8Mbit connection and that’s about it. We have no servers and no standard settings and staff are encouraged to bring in their own laptops and connect! The network basically exists to provide internet access and that’s it. We also have students accessing the wireless (and I know there’s a whole list of access and content issues etc but right now we just need internet access stabilised). This is what we have: Building 1 Cisco SLM-224P 24-port PoE 10/100 switch with 2 gigabit ports 3 x ZyXEL NWA-3160 wireless APs Samsung OfficeServ 7100 phone server which borrows the building’s wiring Building 2 Netgear GS605-UK 5-port 10/100/1000 switch 1 x ZyXEL NWA-3160 wireless AP 1 x BT Business Hub – 2wire BT2700hgv – is the DHCP server We have 2 link cables between the buildings. One connects the two switches on a gigabit port. The second (oddly) connects the switch in building 2 to the OfficeServ server in building 1. When the internet goes down I can still access the router through a wireless connection. I can also ping websites and get a response. Firefox just says “Cannot connect” etc. The system then heals itself when it feels like it. (Sorry if this is asking too much but) These are my immediate questions… Why would browser-based internet go down? I don’t know enough about protocols etc but I can try to standardise settings. The WAPs have a DNS server setting and I don’t know whether it should be “None” or “From DHCP”. What should be the DHCP server? The router or the Cisco switch? Or something else?! Would there be any problem in connecting the second link from switch to switch? Is that good practice? Is it worth swapping the Netgear GS605 with either a Cisco SG200-08 or Netgear GS108T-200? Is it worth upgrading the router to, for instance, a Cisco RV042G Dual Gigabit router which would also act as a switch? Or is it better to have a separate router and switch in Building 2?

    Read the article

  • windows server 2008 r2 remote desktop issue with roaming clients

    - by Patrick D'Haese
    I have the following situation : a Dell windows server 2008 R2 computer, with remote desktop services installed. I have installed a java application making use of a PostgreSql database, and made this application available for clients using RDP. Clients are standard Win XP pc's and Psion Neo handheld devices running Windows CE 5 Pro. The application works fine for clients on standard XP pc's connected directly via cat 5E Ethernet cable to a Dell Powerconnect 2816 switch. The Psion Neo clients connect wireless to the network via Motorola AP6532 access points. These access points are connected via a POE adapter to the same switch as the XP pc's. The Psion devices can connect without any problem and very quickly to the server and to the application using RDP. So far, so good. When the Psion devices move around in the warehouse, and they roam from one access point to the other, the RDP session on the client freezes for approx 1 minute, and then it automatically resumes the session. This freezing is very annoying for the users. Can anyone help in solving this issue? Update (August 9) : After re-installing the access points we have a working situation, but only when connecting to the RDP host : * via a Win Xp SP3 laptop * via a Symbol MC9190 Win CE 6 mobile device When roaming we notice a small hick-up less then 1 second, what is very acceptable. With the Psion NEO it's still not working, when roaming the screen freezes from 2 to 30 seconds. The RDP client on the win xp sp3 laptop and the symbol mc9190 is version 6.0. The RDP client on the neo is version 5.2. I have changed the security layer on the RDP host to RDP security layer (based on forums on the internet), because older RDP clients seem to have issues with the RDP 7.1 protocol on the Win server 2088 R2. Psion adviced us to do some network logging activity on the different devices. We made this logging via wireshark, and based on this the conclusion of Psion is that the server fails in handling tcp-requests. Can anyone give me a second opinion by analysing the wireshark loggings. Thanks in advance. Regards Patrick

    Read the article