  • please demystify the 10Gb ethernet interfaces, cables

    - by maruti
    this really is a Dell question but tempted to ask the experts @ serverfault. choosen a Dell powerconnect 8024 10GbE switch. per the spec sheet this has 10GbaseT ports. "24x 10GBASE-T (10Gb/1Gb/100Mb) with 4x Combo Ports of SFP+ (10Gb/1Gb) or 10GBASE-T" the HBA on my storage server has 10G CX4 copper ports Dell does not sell any cables and this adds to my confusion. from the picture Dell 8024 seems to have RJ-45 type ports on the front panel? my question: is it a RJ-45 + CX4 cable or CX4 + CX4 cable?

    Read the article

  • Rough estimate for speed advantage of SAN-via-fibre to san-via-iSCSI when using VMware vSphere

    - by Dirk Paessler
    We are in the process of setting up two virtualization servers (DELL R710, Dual Quadcore Xeon CPUs at 2.3 Ghz, 48 GB RAM) for VMware VSphere with storage on a SAN (DELL Powervault MD3000i, 10x 500 GB SAS drives, RAID 5) which will be attached via iSCSI on a Gbit Ethernet Switch (DELL Powerconnect 5424, they call it "iSCSI-optimized"). Can anyone give an estimate how much faster a fiber channel based solution would be (or better "feel")? I don't mean the nominal speed advantage, I mean how much faster will virtual machines effectively work? Are we talking twice the speed, five times, 10 times faster? Does it justify the price? PS: We are not talking about heavily used database servers or exchange servers. Most of the virtualized servers run below 3-5% average CPU load.

    Read the article

  • LAN speeds and firewall/switch connections

    - by microchasm
    I have a small network with about ten users. All workstations flow into a Dell PowerConnect 3424 which then has a single link to a SonicWALL firewall and from there to a cable modem. More important than internet connectivity is speed between machines (specifically a Windows Server box on the LAN which everyone uses simultaneously). I believe the 3424 has gigabit connections, but they look like they're for stacking. Is there a way to test the speeds on the LAN to see where the speeds are at? Is there any low-hanging fruit insofar as increasing speeds?

    Read the article

  • How long do managed gigabit ethernet switches take to boot up?

    - by Warren P
    One critical drawback that I have found in researching managed-switches, and one that I have some past experience with is that anything with "lots" of firmware is going to have lots of issues associated with that firmware. We are in the middle of researching rackmount gigabit switches (48 port). It looks like for 48 ports, our only choice is managed switches (Dell, Cisco/Linksys,HP, etc). What I want to know, that I can not find out much about is the boot-time for various managed switches. If you own one, can you please answer with the model number, and the cold boot time in seconds. I have read online that Linksys (now Cisco) SRW series sometimes take almost 5 minutes before they are fully booted up, and that is an unacceptable cost for us. I particularly want to know about Dell PowerConnect managed switch bootup time (model 3548 and 5448), and would like to confirm the 5-minute boot time on the SRW2048 or similar model, and any HP ProCurve boot up times. The composite of all those figures ought to form an interesting overall performance picture.

    Read the article

  • how to design network for connectivity between private and corporate LANs?

    - by maruti
    there is a bunch of servers connected to shared storage in a private LAN (10.x.x.x). this privateLAN is managed by a windows server (DHCP, DNS and directory services) these hosts need to be from outside of the datacenter Eg. Remote desktop. can the NIC2 on each of the hosts be connected to the other public LAN (compromising speed or security? what are improtant considerations: additional hardware? like switches? routing&DNS software? currently available hardware : Dell Powerconnect 6224 switch .... planning this for storage network. software: windows 2003 server for DHCP, DNS, A/D ? would it be more flexible to use Linux distributions like IPCOP, Untangle etc? all that I am looking for is good isolation between private and other networks, avoid DHCP, DNS, AD clashes.

    Read the article

  • How to best tune my SAN/Initiators for best performance?

    - by Disco
    Recent owner of a Dell PowerVault MD3600i i'm experiencing some weird results. I have a dedicated 24x 10GbE Switch (PowerConnect 8024), setup to jumbo frames 9K. The MD3600 has 2 RAID controllers, each has 2x 10GbE ethernet nics. There's nothing else on the switch; one VLAN for SAN traffic. Here's my multipath.conf defaults { udev_dir /dev polling_interval 5 selector "round-robin 0" path_grouping_policy multibus getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout none path_checker readsector0 rr_min_io 100 max_fds 8192 rr_weight priorities failback immediate no_path_retry fail user_friendly_names yes # prio rdac } blacklist { device { vendor "*" product "Universal Xport" } # devnode "^sd[a-z]" } devices { device { vendor "DELL" product "MD36xxi" path_grouping_policy group_by_prio prio rdac # polling_interval 5 path_checker rdac path_selector "round-robin 0" hardware_handler "1 rdac" failback immediate features "2 pg_init_retries 50" no_path_retry 30 rr_min_io 100 prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } And iscsid.conf : node.startup = automatic node.session.timeo.replacement_timeout = 15 node.conn[0].timeo.login_timeout = 15 node.conn[0].timeo.logout_timeout = 15 node.conn[0].timeo.noop_out_interval = 5 node.conn[0].timeo.noop_out_timeout = 10 node.session.iscsi.InitialR2T = No node.session.iscsi.ImmediateData = Yes node.session.iscsi.FirstBurstLength = 262144 node.session.iscsi.MaxBurstLength = 16776192 node.conn[0].iscsi.MaxRecvDataSegmentLength = 262144 After my tests; i can barely come to 200 Mb/s read/write. Should I expect more than that ? Providing it has dual 10 GbE my thoughts where to come around the 400 Mb/s. Any ideas ? Guidelines ? Troubleshooting tips ?

    Read the article

  • How do I keep a bridge enabled on a bonded interface?

    - by jlawer
    I'm working on setting up a pair of CentOS 6.3 servers that will run a couple of KVM vms and have come across a problem setting up a bridge on a bond. I am using Mode 4 (802.3ad) bonding on a pair of stacked Dell Powerconnect 5524 switches connecting to R320 servers. There are 2 links (1 to each switch) that form a Link Aggregation Group (802.3ad / LACP bonding). On top of the bond I have VLAN Tagging. I've verified this is a problem on multiple other bonding modes so it isn't just a mode 4 issue. I am testing what happens when 1 link is dropped (ie switch dies, cable breaks, etc). If I don't have a bridge (for KVM), everything works fine, failover happens as expected. If I have the bridge enabled, it works fine until failover (unplugging a cable). When failover happens /var/log/messages shows the slave link going down, followed within a second by: kernel: br1: port 1(bond0.8) entering disabled state The thing is /proc/net/bonding/bond0 shows the link is up as expected (simply with only 1 slave instead of 2). If I plug the cable back in it recovers and brings the bridge back to an enabled state. I actually have tested this while a ping is occuring and if the timing is right a packet will actually leave the system after the link is lost, but before the disabled message occurs. This disabled state I assumed was STP, but I have disabled STP on the bridge configuration and this issue still occurs. brctl showstp br1 still shows the link as disabled when it is running without a slave. I also switched between the nics in the server (I have 2x Broadcom & 4x intel). It doesn't matter which configuration I have. Does anyone know of a way to force the bridge to stay enabled or why its detecting the bond as disabled, when it isn't?

    Read the article

  • Network connection keeps dropping - bad hardware?

    - by Bill Sambrone
    Hello all, I've into a bit of a wall with a client of mine. In an office of 20 people, he is the only one who experiences broken connections to his mapped network drives. I have everyone set up with about 6 mapped drives, all pointing to the same server (no DFS), and everyone else can access them lightning fast. The environment consists of a mix of Windows 7 and XP machines, all 32-bit. The server holding the data everyone is mapping to is running on Server 2008 R2, and is a domain controller. We recently swapped out their old 10/100 switch for a shiny new Dell PowerConnect gigabit switch. We have also replaced an old dying Sonicwall with a shiny new one. Everything is running on an ESX host except for the DC, where everyone is getting data from. In my client's office, we have done the following: Swapped out his computer (Win7 and XP box) Swapped out the desktop switch in his office Removed the desktop switch in his office Changed out the network cable going to the wall Ran 'net config server /autodisconnect:-1' on the server Disabled remote differential compression on his current Win7 box When we swapped out his network cable, everything seemed fine for about 4 days. Normally I would get a phone call a couple times per day letting me know that Outlook has crashed (there is a 9GB PST living on the server he is always connected to), or that his software he is running from his L drive has crashed. I almost thought I had this solved, but after we rebooted the DC the other night he all of a sudden couldn't stay connected to his mapped network drives for more than 10 minutes. When I ran 'net use' from the command prompt, it listed all the network drives where were randomly in a state of 'OK', 'Disconnected', or 'Reconnecting'. What else should I try? Maybe there is bad wiring in the wall, patch panel, or a bad port in the new switch I have in the server room?

    Read the article

  • windows server 2008 r2 remote desktop issue with roaming clients

    - by Patrick D'Haese
    I have the following situation : a Dell windows server 2008 R2 computer, with remote desktop services installed. I have installed a java application making use of a PostgreSql database, and made this application available for clients using RDP. Clients are standard Win XP pc's and Psion Neo handheld devices running Windows CE 5 Pro. The application works fine for clients on standard XP pc's connected directly via cat 5E Ethernet cable to a Dell Powerconnect 2816 switch. The Psion Neo clients connect wireless to the network via Motorola AP6532 access points. These access points are connected via a POE adapter to the same switch as the XP pc's. The Psion devices can connect without any problem and very quickly to the server and to the application using RDP. So far, so good. When the Psion devices move around in the warehouse, and they roam from one access point to the other, the RDP session on the client freezes for approx 1 minute, and then it automatically resumes the session. This freezing is very annoying for the users. Can anyone help in solving this issue? Update (August 9) : After re-installing the access points we have a working situation, but only when connecting to the RDP host : * via a Win Xp SP3 laptop * via a Symbol MC9190 Win CE 6 mobile device When roaming we notice a small hick-up less then 1 second, what is very acceptable. With the Psion NEO it's still not working, when roaming the screen freezes from 2 to 30 seconds. The RDP client on the win xp sp3 laptop and the symbol mc9190 is version 6.0. The RDP client on the neo is version 5.2. I have changed the security layer on the RDP host to RDP security layer (based on forums on the internet), because older RDP clients seem to have issues with the RDP 7.1 protocol on the Win server 2088 R2. Psion adviced us to do some network logging activity on the different devices. We made this logging via wireshark, and based on this the conclusion of Psion is that the server fails in handling tcp-requests. Can anyone give me a second opinion by analysing the wireshark loggings. Thanks in advance. Regards Patrick

    Read the article

  • How to configure multiple iSCSI Portal Groups on a EqualLogic PS6100?

    - by kce
    I am working on a migration from a VMware vSphere environment to a Hyper-V Cluster utilizing Windows Server 2012 R2. The setup is pretty small, an EqualLogic PS6100e and two Dell PowerConnect 5424 switches and handful of R710s and R620s. The SAN was configured as a non-RFC1918 network that is not assigned to our organization and since I am working on building a new virtualization environment I figured that this would be an appropriate time to do a subnet migration. I configured a separate VLAN and subnet on the switches and the two previously unused NICs on the PS6100's controllers. At this time I only have a single Hyper-V host cabled in but I can successfully ping the PS6100 from the host. From the PS6100 I can ping each of the four NICs that currently on the storage network. I cannot connect the Microsoft iSCSI Initiator to the Target. I have successfully added the Target Portals (the IP addresses of PS6100 NICs) and the Targets are discovered but listed as inactive. If I try to Connect to them I get the following error, "Log onto Target - Connection Failed" and ISCSIPrt 1 and 70 events are recorded in the Event Log. I have verified that access control to the volume is not the problem by temporarily disabling it. I suspect the problem is with the Portal Group IP address which is still listed as Group Address of old subnet (I know, I know I might be committing the sin of the X/Y problem but everything else looks good): RFC3720 has this to say about Network Portal and Portal Groups: Network Portal: The Network Portal is a component of a Network Entity that has a TCP/IP network address and that may be used by an iSCSI Node within that Network Entity for the connection(s) within one of its iSCSI sessions. A Network Portal in an initiator is identified by its IP address. A Network Portal in a target is identified by its IP address and its listening TCP port. Portal Groups: iSCSI supports multiple connections within the same session; some implementations will have the ability to combine connections in a session across multiple Network Portals. A Portal Group defines a set of Network Portals within an iSCSI Network Entity that collectively supports the capability of coordinating a session with connections spanning these portals. Not all Network Portals within a Portal Group need participate in every session connected through that Portal Group. One or more Portal Groups may provide access to an iSCSI Node. Each Network Portal, as utilized by a given iSCSI Node, belongs to exactly one portal group within that node. The EqualLogic Group Manager documentation has this to say about the Group IP Address: You use the group IP address as the iSCSI discovery address when connecting initiators to iSCSI targets in the group. If you modify the group IP address, you might need to change your initiator configuration to use the new discovery address Changing the group IP address disconnects any iSCSI connections to the group and any administrators logged in to the group through the group IP address. Which sounds equivalent to me (I am following up with support to confirm). I think a reasonable explanation at this point is that the Initiator can't complete the connection to the Target because the Group IP Address / Network Portal is on a different subnet. I really want to avoid a cutover and would prefer to run both subnets side-by-side until I can install and configure each Hyper-V host. Question/s: Is my assessment at all reasonable? Is it possible to configure multiple Group IP Addresses on the EqualLogic PS6100? I don't want to just change it as it will disconnect the remaining ESXi hosts. Am I just Doing It Wrong(TM)?

    Read the article