  • VMware vSwitches and Dell PowerConnect BPDU guard

    - by dunxd
    I am using two Dell PowerConnect 6248 switches to connect a VMware host vSwitch. A discussion of config of Cisco switches for use with VMware advises to set physical ports connected to vSwitch with bpduguard and portfast. However, Dell switches don't have the bpduguard setting for individual ports. I can switch it off globally for all portfast ports, but I don't think I want to do that. Should I: Disable STP on the vSwitch connected ports? Leave STP on and enable portfast on the ports, and forget about bpduguard? Disable bpduguard on all portfast ports via global config Do something else? See also: VMware vSwitches and spanning tree

    Read the article

  • NIC Bonding/balance-rr with Dell PowerConnect 5324

    - by Branden Martin
    I'm trying to get NIC bonding to work with balance-rr so that three NIC ports are combined, so that instead of getting 1 Gbps we get 3 Gbps. We are doing this on two servers connected to the same switch. However, we're only getting the speed of one physical link. We are using 1 Dell PowerConnect 5324, SW version 2.0.1.3, Boot version 1.0.2.02, HW version 00.00.02. Both servers are CentOS 5.9 (Final) running OnApp Hypervisor (CloudBoot) Server 1 is using ports g5-g7 in port-channel 1. Server 2 is using ports g9-g11 in port-channel 2. Switch show interface status Port Type Duplex Speed Neg ctrl State Pressure Mode -------- ------------ ------ ----- -------- ---- ----------- -------- ------- g1 1G-Copper -- -- -- -- Down -- -- g2 1G-Copper Full 1000 Enabled Off Up Disabled Off g3 1G-Copper -- -- -- -- Down -- -- g4 1G-Copper -- -- -- -- Down -- -- g5 1G-Copper Full 1000 Enabled Off Up Disabled Off g6 1G-Copper Full 1000 Enabled Off Up Disabled Off g7 1G-Copper Full 1000 Enabled Off Up Disabled On g8 1G-Copper Full 1000 Enabled Off Up Disabled Off g9 1G-Copper Full 1000 Enabled Off Up Disabled On g10 1G-Copper Full 1000 Enabled Off Up Disabled On g11 1G-Copper Full 1000 Enabled Off Up Disabled Off g12 1G-Copper Full 1000 Enabled Off Up Disabled On g13 1G-Copper -- -- -- -- Down -- -- g14 1G-Copper -- -- -- -- Down -- -- g15 1G-Copper -- -- -- -- Down -- -- g16 1G-Copper -- -- -- -- Down -- -- g17 1G-Copper -- -- -- -- Down -- -- g18 1G-Copper -- -- -- -- Down -- -- g19 1G-Copper -- -- -- -- Down -- -- g20 1G-Copper -- -- -- -- Down -- -- g21 1G-Combo-C -- -- -- -- Down -- -- g22 1G-Combo-C -- -- -- -- Down -- -- g23 1G-Combo-C -- -- -- -- Down -- -- g24 1G-Combo-C Full 100 Enabled Off Up Disabled On Flow Link Ch Type Duplex Speed Neg control State -------- ------- ------ ----- -------- ------- ----------- ch1 1G Full 1000 Enabled Off Up ch2 1G Full 1000 Enabled Off Up ch3 -- -- -- -- -- Not Present ch4 -- -- -- -- -- Not Present ch5 -- -- -- -- -- Not Present ch6 -- -- -- -- -- Not Present ch7 -- -- -- -- -- Not Present ch8 -- -- -- -- -- Not Present Server 1: cat /etc/sysconfig/network-scripts/ifcfg-eth3 DEVICE=eth3 HWADDR=00:1b:21:ac:d5:55 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth4 DEVICE=eth4 HWADDR=68:05:ca:18:28:ae USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth5 DEVICE=eth5 HWADDR=68:05:ca:18:28:af USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-onappstorebond DEVICE=onappstorebond IPADDR=10.200.52.1 NETMASK=255.255.0.0 GATEWAY=10.200.2.254 NETWORK=10.200.0.0 USERCTL=no BOOTPROTO=none ONBOOT=yes cat /proc/net/bonding/onappstorebond Ethernet Channel Bonding Driver: v3.4.0-1 (October 7, 2008) Bonding Mode: load balancing (round-robin) MII Status: up MII Polling Interval (ms): 100 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth3 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 00:1b:21:ac:d5:55 Slave Interface: eth4 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:28:ae Slave Interface: eth5 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:28:af Server 2: cat /etc/sysconfig/network-scripts/ifcfg-eth3 DEVICE=eth3 HWADDR=00:1b:21:ac:d5:a7 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth4 DEVICE=eth4 HWADDR=68:05:ca:18:30:30 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-eth5 DEVICE=eth5 HWADDR=68:05:ca:18:30:31 USERCTL=no BOOTPROTO=none ONBOOT=yes MASTER=onappstorebond SLAVE=yes cat /etc/sysconfig/network-scripts/ifcfg-onappstorebond DEVICE=onappstorebond IPADDR=10.200.53.1 NETMASK=255.255.0.0 GATEWAY=10.200.3.254 NETWORK=10.200.0.0 USERCTL=no BOOTPROTO=none ONBOOT=yes cat /proc/net/bonding/onappstorebond Ethernet Channel Bonding Driver: v3.4.0-1 (October 7, 2008) Bonding Mode: load balancing (round-robin) MII Status: up MII Polling Interval (ms): 100 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth3 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 00:1b:21:ac:d5:a7 Slave Interface: eth4 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:30:30 Slave Interface: eth5 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 68:05:ca:18:30:31 Here are the results of iperf. ------------------------------------------------------------ Client connecting to 10.200.52.1, TCP port 5001 TCP window size: 27.7 KByte (default) ------------------------------------------------------------ [ 3] local 10.200.3.254 port 53766 connected with 10.200.52.1 port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 950 MBytes 794 Mbits/sec

    Read the article

  • Why we do not use PowerConnect to access PeopleSoft Tree

    - by dylan.wan
    1. It does not allow you to use parameters to the PeopleSoft connect. It may be changed later. However, it was a big issue when we try to address customer issues. 2. It requires EFFDT as an option. It expect that people change the EFFDT using Mapping Editor. How can a business user does that every month? 3. It asks for a Tree Name. Many PeopleSoft tree structure supports multiple trees. Tree is just a header of the hierarchy. Whenever you add a new Tree, you need to create a new mapping!! It does not make sense to use PowerConnect due to the customer demands. All requirements are from customers. We have no choice but stop using it.

    Read the article

  • Windows Network Load Balancing on ESX Cluster with Dell PowerConnect stacks

    - by dunxd
    We recently switched out our Cisco 6500 core switch for a pair of Dell PowerConnect 6248 stacks. Since then, our Network Load Balanced Sharepoint, which runs on two virtual machines on an ESX cluster has been behaving very poorly. The symptoms are that opening and saving documents stored in sharepoint takes a very very long time. There are no errors showing up on the Sharepoint servers or SQL server, just a lot of annoyed users. Initially I thought there was no way NLB could cause this, but as soon as we repointed the DNS records for our intranet to the ip address of one of the web front ends, the problems disappeared. We suspect there is an issue related to multicast in the Dell configs - NLB is configured for multicast, but not IGMP. Has anyone got a similar set up to us and fixed this sort of issue? Sharepoint on VMware ESX, with Dell PowerConnect switches.

    Read the article

  • Getting packets from one port to another on a Dell PowerConnect 2824 switch

    - by Arvo Bowen
    I have a dell PowerConnect 2824 and I have a cat 5 cable connected from port 1 to port 23. Port 1 is reserved for VLAN 1 (the only VLAN that can manage the switch) and port 18-23 belong to VLAN 112. I currently have the switch setup with ip 10.71.3.5/27 and a test machine plugged into port 22 with IP address 10.71.3.30/27. For some reason I can not ping 10.71.3.5 from my test machine (10.71.3.30). Note: When I try to ping the server plugged into port 21 (IP: 10.71.3.7/27) also VLAN 112, I get responses just fine. Note: When I plug my test machine directly into port 1, I can ping 10.71.3.5 just fine. Quick Recap: Switch IP: 10.71.3.5 Port 1 - dedicated to management - (VLAN1) Port 21 - SERVER (10.71.3.7/27) - (VLAN112) Port 22 - test machine (10.71.3.30/27) - (VLAN112) Port 23 - dedicated to management (to hop over to VLAN 1 from VLAN 112) - (VLAN112)

    Read the article

  • How to troubleshoot slow powerconnect 62xx management interface

    - by Hannes
    Our Dell Powerconnect 62xx switches have a very high packetloss on the management interface. I presume this is caused by a new appliance which uses multicast for communication but I am not sure. Our network setup is following: servers a - Dell PC6248 | servers b - Dell PC6248 |- juniper core router servers c - Dell PC6248 | What we see is that the multicast traffic arrives at all servers (but only the servers b use the multicast) and I fear that this multicast traffic floods the switch management interface. The switches' management interfaces are reachable via vlan101, all other traffic is sent over other vlans. When I tcpdump on one of the 2 servers with a vlan 101 ip address, I only get a few arp requests but almost nothing. When I try to ping between these 2 servers, it works like a charm. I would like to know what a good way is to troubleshoot this problem and maybe help me understand what is going wrong on that subnet.

    Read the article

  • Ruckus wireless AP and Dell PowerConnect configuration problems

    - by DanielJay
    We are working on trying to get some Ruckus Access Points to work correctly on our network. Currently our network is as follows: VLAN 10 - Servers VLAN 11 – Computers/DHCP VLAN 12 – Voice VLAN 13 – Guest We use Dell PowerConnect 6248P switches for our switches. Port settings are as follows: ZoneDirector 1100 is plugged into this port. Should be accessing the server VLAN and then allowing all other traffic. interface ethernet 1/g2 classofservice trust ip-dscp description 'Ruckus ZoneDirector 1100' switchport mode general switchport general pvid 10 switchport general allowed vlan add 10 switchport general allowed vlan add 11-13 tagged exit Access point is plugged into this port. The port has to be on VLAN 11 in order to get DHCP. interface ethernet 1/g16 classofservice trust ip-dscp description 'Ruckus - IT' switchport mode general switchport general pvid 11 switchport general allowed vlan add 10-12 switchport general allowed vlan add 13 tagged exit If we tag the traffic from the SSID as VLAN 11 data fails. If we leave the SSID tagged as 1 the data flows correctly. Are there problems with passing tagged traffic to untagged ports? We are looking to see what we can do to get the SSID tagged as 11 instead of 1. Any suggestions?

    Read the article

  • PowerConnect 3548p SNTP and web interface not working

    - by Force Flow
    I have been unable to get SNTP and access to the web interface working properly on a Dell PowerConnect 3548p. In the logs, this message appears over and over again: 04-Jan-2000 20:19:29 :%MNGINF-W-ACL: Management ACL drop packet received on interface Vlan 172 from 172.17.0.3 to 172.18.0.10 protocol 17 service Snmp 172 is the management vlan. 172.17.0.3 is the DNS server 172.18.0.10 is the switch's IP address. The DNS server and the switch are located on different subnets and separated by routers. I am unable to access the web interface of the switch from the 172.17.x.x subnet. I can only access the web interface of the switch if I am accessing it from the 172.18.x.x subnet. There is also a managed linksys switch on the 172.18.x.x subnet on the 172 vlan, which has no problem with SNTP. I can also access it from the 172.17.x.x network. So, it stands to reason that this is not a firewall or routing issue, but with the 3548p switch. I suspect the issue is with management permissions/ACLs on the 3348p switch, but that's about as much as I've been able to determine so far. Any ideas?

    Read the article

  • Broadcom NIC Teaming w/ 802.3ad and Dell Powerconnect 2824

    - by Carltoncl
    We have a Poweredge R210 running WS2K8R2. The server has two Broadcom 5716C NICs running Broadcom BASP. I can team the NICs using the 802.3ad protocol on the server end no problem. I have no VLAN. Now I go to the 2824 switch (default settings all round) running in managed mode and create a LAG with ports g1 and g2. As soon as I add these ports, I lose the ability to send traffic to or from the server. I am much more of a server guy than a networking guy, what am I doing wrong here? Server Static IP Address: 10.10.61.15 Network mask: 255.255.255.0 Gateway: 10.10.61.51 The 2824 switch has an IP address of 10.10.61.51 and in turn has its gateway as our firewall server running ISA Server at 10.10.61.50.

    Read the article

  • How to reset password for Dell PowerConnect 2708?

    - by oherrala
    I do as the user manual says and press "Managed Mode" button to get into unmanaged mode and then press "Managed Mode" button again for managed mode. This should reset the device to factory defaults and username "Admin" with no password. However, the device resets (I think) and I can access the web console from IP 192.168.2.1, but the username and password doesn't work. Maybe the device doesn't reset after all. Or the username/password has been changed in some firmware upgrade? What should I do to get into management of this switch?

    Read the article

  • Dell powerconnect 6224 vlan routing

    - by user1007727
    I have a small network and I need help with routing .. . My VLANs VLAN 1010 SALES VLAN 1020 HR I have assigned the above vlans to a tagged port and I have added a default route to send the traffic of to my firewall. ip route 0.0.0.0 0.0.0.0 10.10.10.10 I have added a new vlan VLAN 1030 Services and I would like its traffic to go to a different interface on the firewall, 10.10.10.20 how can I go about doing that? can someone give me an example? your help is highly appreciated. Thank you

    Read the article

  • Why DELL PowerConnect and Juniper are so rare ? Why do enterprises stick with Cisco ?

    - by Kedare
    Hello ! I have a little question, I'm actually studing IT in France, and when looking on alternative on the very [...] very expensive Cisco equipments, I've found Juniper and DELL PowerConnect pretty attractive on features and price, but I rarely see something else than the classics Cisco/LinkSys, HP Procurve and Netgear.. Why it's so rare to find those switch ? They looks really great but... I've never seen any Juniper or Powerconnect... Why do enterprises stick with the expensive Cisco ? I've tried to find how to buy both, it's quite easy with PowerConnect, everything is on the DELL website, but it looks it's very hard to find Juniper equipments in France :( Thank you !

    Read the article

  • Why PowerConnect and Juniper are so rare ? Why do enterprises stick with Cisco ?

    - by Kedare
    Hello ! I have a little question, I'm actually studing in IT in France, and when looking on alternative on the very [...] very expensive Cisco equipment, I've found Juniper and DELL PowerConnect pretty attractive on features and price, but I rarely see something else than the classics Cisco/LinkSys, HP Procurve and Netgear.. Why it's so rare to find those switch ? They looks really great but... I've never seen any Juniper or Powerconnect... Why do enterprises stick with the expensive Cisco ? I've tried to find how to buy both, it's quite easy with PowerConnect, everything is on the DELL website, but it looks it's very hard to find Juniper equipment in France :( Thank you !

    Read the article

  • Anyone love/hate the PowerConnect line of switches from Dell?

    - by Rob Bergin
    I am looking at replacing some unmanaged 16 port store bought GB switches and wanted to go with Cisco but it may be cost prohibitive. Instead I am looking at ProCurve or Dell's PowerConnect line up. I am looking for SNMP, Management, VLANs, and SFLOW would icing on the switch cupcake. I would get the 6224 or the 6248 and then maybe add the RPS-600 to it for redundant power. I think the RPS-600 supports multiple switches. Rackspace is also a little challenge so I am trying to do it with as little Rack Units as possible. Ideally I would go with two 6224's or a single 6248 and then do two VLANs. Thanks for any feedback. Rob

    Read the article

  • How to set a management IP on a Dell powerconnect 5524/5548 switch?

    - by John Little
    When you first power on a 5524, connected via the serial console, you are offered a setup wizard where you can enter the management IP/Net/Gateway and enter the admin password. HOWEVER, if you dont do this in 60 seconds, the wizard dissapears, and there seems to be no way to run it again - even if you reboot the box. No commands work in the CLI, it just gives you this prompt: If you type say enable, or login, it gives: >login Unknown parameter May be one from the following list: debug help So no commands seem to work. The CLI reference guide does not seem to have any way to run the wizard, or to set the management port or admin passwords. So by not responding in 60 secons after boot, the unit is bricked. Any ideas?

    Read the article

  • PowerConnect 2848 , vlan configuration with AP

    - by Francesco
    I need to configure two vlan on an AP connected with a Dell PowerConnect 2848. The first one is up and running (let's say vlan x) , the second one is a completely different network (vlan y) , provided by a Gateway-DHCP wich i have no access, directely Patched (via patch panel) at a secondo AP device. So i cannot just plug this Gateway device on my switch without tagging traffic before, for DHCP collion . I have to solve this problem. I was thinking about tagging the traffic at the port wich I will connect the gateway device with vlan y and then set as trunk (vlanx+y) the AP port. In this way I hope to limit the vlan y traffic ONLY for the ports I selected avoiding the spread of unwanted dhcp calls. But all other ports are Unassigned , so I am not sure they won't forward dhcp (vlan y) traffic. I cannot change the Unassigned state for the vlan x ports cause vlanx is native.

    Read the article

  • Set 802.1Q tagged port on VLAN1 on Dell PowerConnect switch

    - by Javier
    I'm having big troubles when adding this Dell switch to my network. Here we use several VLANs to segment traffic. All switches (3com and DLink mostly) have configured the same VLANs, most ports are 'untagged' and belong to a single VLAN, except for the ports used to join together the switches (in a star topology), these ports belong to all VLANs and use 802.1Q tags. So far, it works really well. But on this new switch (a Dell PowerConnect 5448), the settings are very different (and confusing). I have configured the same VLANs, an the uplink ports are set in 'general' mode (supposed to be fully 802.1Q compliant), I can set the VLAN membership as 'T' on these ports for all VLANs except VLAN 1. It always stay as 'U' on VLAN 1. Any ideas?

    Read the article

  • Set 802.1Q tagged port on VLAN1 on Dell PowerConnect switch

    - by Javier
    I'm having big troubles when adding this Dell switch to my network. Here we use several VLANs to segment traffic. All switches (3com and DLink mostly) have configured the same VLANs, most ports are 'untagged' and belong to a single VLAN, except for the ports used to join together the switches (in a star topology), these ports belong to all VLANs and use 802.1Q tags. So far, it works really well. But on this new switch (a Dell PowerConnect 5448), the settings are very different (and confusing). I have configured the same VLANs, an the uplink ports are set in 'general' mode (supposed to be fully 802.1Q compliant), I can set the VLAN membership as 'T' on these ports for all VLANs except VLAN 1. It always stay as 'U' on VLAN 1. Any ideas?

    Read the article

  • Layer 3 switch routing

    - by Yoshiwaan
    I need help moving over to using our layer 3 switch as the inter vlan routing device rather than our cisco router. I've mostly got it working but I've got stuck near the end and need some advice (I think I just need a bit of education on the subject really). Cur I have a Dell PowerConnect 7048 connecting to a Cisco 1841 router. I've got a few key excerpts from the configs to provide the key information. On the powerconnect I have the following: ip routing ip default-gateway 172.31.14.1 ip route 0.0.0.0 0.0.0.0 172.31.14.1 253 ! interface vlan 1 ip address 172.31.14.254 255.255.255.0 exit interface vlan 2 ip address 172.31.19.254 255.255.255.0 exit interface vlan 4 ip address 172.31.16.254 255.255.255.0 ! interface Gi1/0/1 description 'Link to L7Router01' switchport mode trunk switchport trunk allowed vlan except 3,7-4093 exit ! and on the Cisco the following: interface FastEthernet0/0 ip address 172.31.14.1 255.255.255.0 ip nat inside ip virtual-reassembly ! interface FastEthernet0/0.2 description Accounts VLAN encapsulation dot1Q 2 ip address 172.31.19.1 255.255.255.0 ip nat inside ip virtual-reassembly ! interface FastEthernet0/0.4 description Voice VLAN encapsulation dot1Q 4 ip address 172.31.16.1 255.255.255.0 ip nat inside ip virtual-reassembly ! So what I'm doing is moving clients over so that their default gateway is a 172.31.x.254 address rather than a 172.31.x.1 address. This works great for inter-vlan routing, I have no issues with this. The switch can also access the router no worries, and users on the 172.31.14.0/24 network can access all interfaces and sub-interfaces on the router, including 172.31.14.1. They can also access all of the interfaces that the router connects off to, no worries there. The problem I have is that users on the 172.31.16.0/24 and 172.31.19.0/24 subnets cannot access either 172.31.14.1 or any of the subnets the router connects to. They can, however, connect to BOTH of the sub interfaces on the router from either subnet. What am I missing here? Why can't the vlans connect to the non-sub interface on the router? Are tagged packets being sent to this interface?

    Read the article

  • How to Configure Different Gateways for Different VLANs

    - by Bryan
    I have around 10 VLANs, and two different internet gateways. I want traffic on some VLANs to use one gateway, and traffic on other VLANs to use another gateway. (e.g. I wish to route server traffic via one gateway and desktop internet traffic down another). Is it possible to configure different default routes for different VLANs on a Dell 6224 switch? Or is their a better way of doing what I'm trying to achieve? The core switch I am using is a Dell PowerConnect 6224 switch. Currently I'm using: ip route 0.0.0.0 0.0.0.0 10.58.3.16 which creates the default gateway for all VLANs. I did consider adding multiple routes with equal metric, and setting ACLs between the VLANs to deny access to the 'wrong' gateway, but that idea just doesn't feel right to me.

    Read the article

  • Can't reliably ping 6224 router from directly-attached system

    - by David Mackintosh
    OK, here's my situation. This is on the internet. The 6224 is the router in this picture and physically resides in Kanata. Both VLAN 1697 and 3994 are provided by an internet service provider. These VLANs are provided through a single 1Gb ethernet wire. The Kanata hosts are directly attached to the 6224; the other two sites are remote. VLAN 3994 is a single IP address space, so theoretically it shouldn't matter physically where the hosts on that subnet are. Here's the problem. I have a monitoring system which is connected further into the internet, so probes from the monitor would come in to this diagram on the 1697 VLAN. When I ping hosts at Albert or Bells Corners from the internet, there is 0 loss. The connection looks perfect. When I ping hosts at Kanata, I lose anywhere from 10 to 40% of the pings. The loss is not predictable, but: when I do lose them, I always lose at least 3, usually 4, rarely more, pings in a bunch. I have attached a monitor directly to the 6224 in Kanata on 3994.. When the monitor pings the 6224 routing interface, I see exactly the same loss pattern -- but NOT at the same time as the loss from the remote system. Ping time is around 1ms. When the monitor pings another system directly attached to the 6224, there is 0 loss. Ping time is about 0.1ms, one-tenth of the time to ping the router. Anyone know what is going on here?

    Read the article

  • Using a Dell PowerConnect to set up load balancing/redundancy, 1 switch 2 routres 2 private wan link

    - by MarianoC
    Hi, We have different locations connected by two different WAN providers. Each site has a dell powerConnect 6224 and two cisco routers with the WAN connections (we don’t have access to router admin). The 6224 connects to each cisco LAN port and to our LAN backbone. We would like the 6224 provide the ip gateway address and load balance and support redundancy, if one of the routes fail. Is this possible?. We can't find any samples on doing this and we have tried with no success. Any help or link to documentation regarding this, will be greatly appreciated. Thanks, MarianoC

    Read the article

  • How do you configuring vlans/trunk on a Cicso ASA 5510

    - by Sam Sanders
    I have a Cicso ASA 5510 that I want to connect to 2 Dell PowerConnect 5500 linked in a Switch Stack. I want to connect a trunking line to each switch so if one switch dies the other works. The problem is I can't seem to do anything thing with vlans on the 5510 using the "Cisco ASDM 6.4 for ASA" . Do I need to use CLI for this, or is it just not possible? I'm new at networking so any advice would be helpful.

    Read the article

  • RV042 - switch needed

    - by David
    I have a Cisco RV042 4-port but unfortunately I ran out of ports and I need to connect 2 more servers to it. I'm planning to get a SOHO switch, but I would like some recommendations before getting one. I was thinking a Dell PowerConnect. Any ideas will be appreciate it.

    Read the article

  • Best way to provide redundant switching/links to server

    - by Myles Gray
    We have 3x ESX hosts and 2x SANS that we wish to move to a redundant 10G networking infrastructure. We have 4x Dell PowerConnect 8024F's to provide our backbone and are configured as so (only core switches relevant to this question): So the questions are: 1) Do the interconnects between the 4x 8024F's need to be LAG'd or just STP'd 2) As the NICs on the servers are split across 2 switches, does any special configuration need to be done here or on the switches? 3) If a link or switch fails will the switches automatically find a new path to the Server/SAN?

    Read the article