Search Results

Search found 28 results on 2 pages for 'qlogic'.

Page 2/2 | < Previous Page | 1 2 

  • Data Store/Volume disconnecting. How to resume copy of VMDK?

    - by Serge
    I'm having an issue with my ESXi 4.1 hosts losing the datastore with FC SAN after a power outage. All 3 hosts disconnect so it's definitely a SAN issue. I've tried to resolve the issue on the SAN side with the SAN software support and Adaptec hardware support. No luck there. So I'm stuck with a SAN that will randomly disconnect the volume. I need to get the virtual machines (VMDK files) from the datastore. The problem is I can only get 5-20% before the data store disconnects. I have backups that are slightly older that I can use to replicate the VMDK differences to. What has not worked so far: Powering up the VMs, will boot up for 5-15 minutes then freeze vCenter migrate or clone of VM, will fail after similar period of time vCenter copy/paste of VMDK. Was able to get one 30GB VMDK and no luck after that. vMware Data Recovery. Fails at low %, can't resume, so next backup starts from begining. Veeam Backup & Recovery. Same as above, no resume function. If I can just find a backup solution that will resume from the failed spot that would solve my issue. Anyone have any ideas that I could try? EDIT 1 The SAN is Open-E DSS 6 running on a Supermicro 24 drive enclosure with 4 port Qlogic FC. Adaptec 52445 RAID card.

    Read the article

  • Ubuntu 10.04 & IBM DS3524 with FC multipath, inactive path is [failed][faulty] instead of [active][ghost]

    - by Graeme Donaldson
    OK, this is my setup: FC Switches IBM/Brocade, Switch1 and Switch2, independent fabrics. Server IBM x3650 M2, 2x QLogic QLE2460, 1 connected to each FC Switch. Storage IBM DS3524, 2x controllers with 4x FC ports each, but only 2x connected on each. +-----------------------------------------------------------------------+ | HBA1 Server HBA2 | +-----------------------------------------------------------------------+ | | | | | | +-----------------------------+ +------------------------------+ | Switch1 | | Switch2 | +-----------------------------+ +------------------------------+ | | | | | | | | | | | | | | | | | | | | +-----------------------------------+-----------------------------------+ | Contr A, port 3 | Contr A, port 4 | Contr B, port 3 | Contr B, port 4 | +-----------------------------------+-----------------------------------+ | Storage | +-----------------------------------------------------------------------+ My /etc/multipath.conf is from the IBM redbook for the DS3500, except I use a different setting for prio_callout, IBM uses /sbin/mpath_prio_tpc, but according to http://changelogs.ubuntu.com/changelogs/pool/main/m/multipath-tools/multipath-tools_0.4.8-7ubuntu2/changelog, this was renamed to /sbin/mpath_prio_rdac, which I'm using. devices { device { #ds3500 vendor "IBM" product "1746 FAStT" hardware_handler "1 rdac" path_checker rdac failback 0 path_grouping_policy multibus prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } multipaths { multipath { wwid xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx alias array07 path_grouping_policy multibus path_checker readsector0 path_selector "round-robin 0" failback "5" rr_weight priorities no_path_retry "5" } } The output of multipath -ll with controller A as the preferred path: root@db06:~# multipath -ll sdg: checker msg is "directio checker reports path is down" sdh: checker msg is "directio checker reports path is down" array07 (xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx) dm-2 IBM ,1746 FASt [size=4.9T][features=1 queue_if_no_path][hwhandler=0] \_ round-robin 0 [prio=2][active] \_ 5:0:1:0 sdd 8:48 [active][ready] \_ 5:0:2:0 sde 8:64 [active][ready] \_ 6:0:1:0 sdg 8:96 [failed][faulty] \_ 6:0:2:0 sdh 8:112 [failed][faulty] If I change the preferred path using IBM DS Storage Manager to Controller B, the output swaps accordingly: root@db06:~# multipath -ll sdd: checker msg is "directio checker reports path is down" sde: checker msg is "directio checker reports path is down" array07 (xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx) dm-2 IBM ,1746 FASt [size=4.9T][features=1 queue_if_no_path][hwhandler=0] \_ round-robin 0 [prio=2][active] \_ 5:0:1:0 sdd 8:48 [failed][faulty] \_ 5:0:2:0 sde 8:64 [failed][faulty] \_ 6:0:1:0 sdg 8:96 [active][ready] \_ 6:0:2:0 sdh 8:112 [active][ready] According to IBM, the inactive path should be "[active][ghost]", not "[failed][faulty]". Despite this, I don't seem to have any I/O issues, but my syslog is being spammed with this every 5 seconds: Jun 1 15:30:09 db06 multipathd: sdg: directio checker reports path is down Jun 1 15:30:09 db06 kernel: [ 2350.282065] sd 6:0:2:0: [sdh] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jun 1 15:30:09 db06 kernel: [ 2350.282071] sd 6:0:2:0: [sdh] Sense Key : Illegal Request [current] Jun 1 15:30:09 db06 kernel: [ 2350.282076] sd 6:0:2:0: [sdh] <<vendor>> ASC=0x94 ASCQ=0x1ASC=0x94 ASCQ=0x1 Jun 1 15:30:09 db06 kernel: [ 2350.282083] sd 6:0:2:0: [sdh] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 Jun 1 15:30:09 db06 kernel: [ 2350.282092] end_request: I/O error, dev sdh, sector 0 Jun 1 15:30:10 db06 multipathd: sdh: directio checker reports path is down Jun 1 15:30:14 db06 kernel: [ 2355.312270] sd 6:0:1:0: [sdg] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jun 1 15:30:14 db06 kernel: [ 2355.312277] sd 6:0:1:0: [sdg] Sense Key : Illegal Request [current] Jun 1 15:30:14 db06 kernel: [ 2355.312282] sd 6:0:1:0: [sdg] <<vendor>> ASC=0x94 ASCQ=0x1ASC=0x94 ASCQ=0x1 Jun 1 15:30:14 db06 kernel: [ 2355.312290] sd 6:0:1:0: [sdg] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 Jun 1 15:30:14 db06 kernel: [ 2355.312299] end_request: I/O error, dev sdg, sector 0 Does anyone know how I can get the inactive path to show "[active][ghost]" instead of "[failed][faulty]"? I assume that once I can get that right then the spam in my syslog will end as well. One final thing worth mentioning is that the IBM redbook doc targets SLES 11 so I'm assuming there's something a little different under Ubuntu that I just haven't figured out yet. Update: As suggested by Mitch, I've tried removing /etc/multipath.conf, and now the output of multipath -ll looks like this: root@db06:~# multipath -ll sdg: checker msg is "directio checker reports path is down" sdh: checker msg is "directio checker reports path is down" xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxdm-1 IBM ,1746 FASt [size=4.9T][features=0][hwhandler=0] \_ round-robin 0 [prio=1][active] \_ 5:0:2:0 sde 8:64 [active][ready] \_ round-robin 0 [prio=1][enabled] \_ 5:0:1:0 sdd 8:48 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 6:0:1:0 sdg 8:96 [failed][faulty] \_ round-robin 0 [prio=0][enabled] \_ 6:0:2:0 sdh 8:112 [failed][faulty] So its more or less the same, with the same message in the syslog every 5 minutes as before, but the grouping has changed.

    Read the article

  • Virtual Machines List from PowerShell vs PowerShell ISE and PowerGUI

    - by slybloty
    I am confused to why I have different information based on where I try to retrieve it from. I have 3 Windows 2012 servers (G0, G1, and G2) running Hyper-V. The following situation is captured from one server which I use to run scripts and control the others. What I'm trying to do is to get a list of the virtual machines in existence on these 3 machines: Using PowerGUI and PowerShell ISE: PS > Get-VMHost | select name Name ---- G0.nothing.com G2.nothing.com G1.nothing.com PS > Get-VMHost | Get-VM | select name Name ---- VM1628856-4 VM1628856-2 VM1628856-6 VM1628856-3 VM1628856-1 VM1628856-5 Using PowerShell: PS > Get-VMHost | select name Name ---- G0 PS > Get-VM Name State CPUUsage(%) MemoryAssigned(M) Uptime Status ---- ----- ----------- ----------------- ------ ------ VM1107610-1 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1390728-1 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1393540-1 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1393540-10 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1393540-2 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1393540-3 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1393540-4 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1393540-5 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1393540-6 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1393540-7 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1393540-8 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1393540-9 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage VM1833022-1 OffCritical 0 0 00:00:00 Cannot connect to virtual machine configuration storage My main concern is that I don't have reliable information from the 3 tools. The Hyper-V Manager application shows the same list as the PowerShell does. But if I run my scripts from the other two tools, which is what I mostly do, I don't have the same information available, therefore I can't manipulate the same VMs. I've also noticed that the Virtual Machine Manager shows the same list of VMs as the first two tools, PowerGUI and PowerShell ISE. Which information is valid? And how can I retrieve the correct list of VMs? EDIT 1 The $env:psmodulepath value: PS > $env:psmodulepath C:\Users\administrator\Documents\WindowsPowerShell\Modules; C:\Windows\system32\WindowsPowerShell\v1.0\Modules\; C:\Program Files (x86)\Microsoft SQL Server\110\Tools\PowerShell\Modules\; C:\Program Files\Microsoft System Center 2012\Virtual Machine Manager\bin\Configuration Providers\; C:\Program Files\Microsoft System Center 2012\Virtual Machine Manager\bin\psModules\; C:\Program Files (x86)\QLogic Corporation\QInstaller\Modules EDIT 2 PowerShell is using this Hyper-V module: C:\Windows\Microsoft.Net\assembly\GAC_MSIL\Microsoft.HyperV.PowerShell\v4.0_6.3.0.0__31bf3856ad364e35\Microsoft.HyperV.PowerShell.dll And PowerGUI is using this one: C:\Windows\System32\WindowsPowerShell\v1.0\Modules\Hyper-V\Hyper-V.psd1 If I try to load the module used by PowerShell onto PowerGUI I still get the same different results. How can I receive the correct information listed under Hyper-V using PowerGUI or PowerShell ISE?

    Read the article

< Previous Page | 1 2