Search Results

Search found 54 results on 3 pages for 'wix3 5'.

Page 2/3 | < Previous Page | 1 2 3  | Next Page >

  • Environment variables get lost between MSBuild projects

    - by DotNetter
    Hi, I have a .NET solution containing following projects: web application (WAP) web deployment (WDP, .wdproj) wix setup (WIX, .wixproj) In the WDP I've used a custom MSBuild task (SetEnvVar) to set some env. variables for further use in the build process. After setting them I can use them without prob. in the WDP but in the WIX they are empty/undefined. The strange thing is that when I reference those env. vars in the WIX files (by using properties in .wxs or preproc vars in .wxi) I get the values as expected. Do you have any idea why the env. vars get lost/are undefined in .wixproj? By the way the (solution) build process is triggered from inside VS 2010.

    Read the article

  • How can my WiX uninstall restore a registry value change?

    - by Thomas
    The installer I'm writing using WiX 3.0 uses a RegistryValue element to modify an existing registry value (originally written by our main product). I'm trying to figure out a way to restore the registry value when the user uninstalls my utility. I'd like to avoid using a custom action, but that might be the only recourse? TIA.

    Read the article

  • Creating a MSI patch (.msp) by hand?

    - by Jerry Chong
    Our team has recently been considering pushing out a minor registry fix to users to modify one particular problematic key. Pretty straightforward stuff, just needed to update 1 key/value inside the registry. So at the moment, we are using Wix to build .msi installers for the product. While looking into Wix's support for generating .msp patch files, it seems that the only way to create an .msp is a somewhat overcomplicated multi-step process to: Get a copy of the original MSI, and compile a new copy of the fixed MSI Write a new Wix file that points to both installers Compile the Wix file into a .wixobj with Candle to a .psp Run Torch/Pyro over before/after snapshots of the original installers and the .psp, or alternatively using MsiMsp.exe Now my question is, can't I simply describe the registry change into a Wix file and directly compile it into the .msp, without step 1 and 4 - which is a huge amount of effort for just a simple change?

    Read the article

  • How can I remove .NET isolated storage setting folders during WiX uninstallation?

    - by Luke
    I would like to remove the isolated storage folders that are created by a .NET application when using My.Settings etc. The setting files are stored in a location like C:\Users\%Username%\AppData\Roaming\App\App.exe_Url_r0q1rvlnrqsgjkcosowa0vckbjarici4 As per this question StackOverflow: Removing files when uninstalling Wix I can uninstall a folder using: <Directory Id="AppDataFolder" Name="AppDataFolder"> <Directory Id="MyAppFolder" Name="My"> <Component Id="MyAppFolder" Guid="YOURGUID-7A34-4085-A8B0-8B7051905B24"> <CreateFolder /> <RemoveFile Id="PurgeAppFolder" Name="*.*" On="uninstall" /> </Component> </Directory> </Directory> <!-- LocalAppDataFolder--> This doesn't support sub-folders etc. Is the only option a custom .NET action or is there a more simple approach for removing these .NET generated setting folders?

    Read the article

  • Can UMDF drivers be packaged/shipped via WiX?

    - by Rafael Rivera
    Howdy Internets: I put together a WiX 3.0 package, utilizing the DIFx extensions, with the intentions to install a Windows 7 Sensor (UMDF driver). During installation, DIFXAPP logged "No matching devices found in INF" and simply threw the driver into storage. I read I'm to populate my INF with an appropriate DriverPackageType, but according to MSDN's enumerated list, nothing fits. Is UMDF driver installation a supported scenario? If not, what's the best practice for using WiX to install such drivers? Disassembling the DIfx extension shows intent to support Co-installer packages, I have yet to try 3.5 beta.

    Read the article

  • How to register file types/extensions with a WiX installer?

    - by OregonGhost
    I didn't find an explicit answer to this question in the WiX Documentation (or Google, for that matter). Of course I could just write the appropriate registry keys in HKCR, but it makes me feel dirty and I'd expect this to be a standard task which should have a nice default solution. For bonus points, I'd like to know how to make it "safe", i.e. don't overwrite existing registrations for the file type and remove the registration on uninstall only if it has been registered during installation and is unchanged.

    Read the article

  • How do I customize what a third party MSM does?

    - by sqlrob
    I'm trying to convert a project in Visual Studio 2008 from static linking of the CRT to dynamic linking. This was easy enough, and I added the CRT MSM and policy MSM to my Wix file with no problems. I am not that happy with the MSI that is output though, it is much larger than what I expected. Looking at the MSI with Orca shows three copies of the CRT DLLs that I need. From looking at the conditions, one of the sets is used for pre-XP installs. Since the system requirements are XP and later, how do I remove this component without touching the original MSM? This needs to be done in an automated build, so Orca isn't a possible solution. Plus, when I tried it with Orca, the filesize remained the same after deleting the File and Component rows. And somewhat related, how do I set the permanent attribute in the components that remain?

    Read the article

  • WiX: Extracting Binary-string in Custom Action yields string like "???good data"

    - by leiflundgren
    I just found a weird behaviour when attempting to extract a string from the Binary-table in the MSI. I have a file containing "Hello world", the data I get is "???Hello world". (Literary question mark.) Is this as intended? Will it always be exactly 3 characters in the beginning? Regards Leif Sample code: [CustomAction] public static ActionResult CustomAction2(Session session) { View v = session.Database.OpenView("SELECT `Name`,`Data` FROM `Binary`"); v.Execute(); Record r = v.Fetch(); int datalen = r.GetDataSize("Data"); System.IO.Stream strm = r.GetStream("Data"); byte[] rawData = new byte[datalen]; int res = strm.Read(rawData, 0, datalen); strm.Close(); String s = System.Text.Encoding.ASCII.GetString(rawData); // s == "???Hello World" return ActionResult.Success; }

    Read the article

  • How to create share for a whole drive under WiX?

    - by mem64k
    I would like to create a share for a whole drive in my WiX installer project. The default approach for share creation works just fine for folders, but not for drives! The following code snippet illustrates the problem: <!-- Works! --> <Property Id="MySharePath"><![CDATA[X:\ROOT]]></Property> <!-- Works NOT! <Property Id="MySharePath"><![CDATA[X:\]]></Property> --> <Directory Id="MySharePath" Name="."> <Component Id="C__AddShare" Guid="$(var.GuidAddhare)" KeyPath="no" Permanent="yes"> <CreateFolder/> <!-- Create necessary share --> <util:FileShare Id="MY_SHARE" Name="MY_SHARE" Description="MY_SHARE"> <util:FileSharePermission ChangePermission="yes" CreateChild="yes" CreateFile="yes" Delete="yes" DeleteChild="yes" GenericAll="yes" GenericExecute="yes" GenericRead="yes" GenericWrite="yes" Read="yes" ReadAttributes="yes" ReadExtendedAttributes="yes" ReadPermission="yes" Synchronize="yes" TakeOwnership="yes" Traverse="yes" User="LukeSkywalker" WriteAttributes="yes" WriteExtendedAttributes="yes"/> </util:FileShare> </Component> </Directory> Does anybody has a hint for this?

    Read the article

  • WiX built-in WixUI Dialog Sets have horizontal lines that are just a little too short (picture inclu

    - by Coder7862396
    I am creating an installer for my program using WiX (Windows Installer XML). I have used the following code to begin using the built-in WixUI Dialog Sets: <Product ...> <UIRef Id="WixUI_FeatureTree" /> </Product> This, however, creates a dialog set with horizontal lines that are just a little bit too short on every dialog as shown here: I understand that I could create my own set of dialogs to use instead by using software such as SharpSetup and WixEdit but I like the dialogs that WiX creates and only want to make a very small change to them. Is my best option to download the WiX source code and try to modify it? Is there a more simple solution? Perhaps I should contact the developers of WiX to list it as a bug? Maybe they like it that way though. I however think it looks out of place and would like to change it. I am using the latest weekly release of WiX 3.5.

    Read the article

  • Disk Cost does not change for a per machine and a per user install

    - by eddie
    I want to know how can i change or rather the computer changes the disk cost in case of a per user or a per machine install. I have an installer that is approximate 50 MB in size when i check in the program files how ever when i am using the DiskCostDlg it shows me 96 MB , i am doing a per user and a per machine install and i am surprised to see that in both the cases the disk requirement is same. I need to know if there is a possibility of changing the disk requirements or is it a default property of the Wix Installer. Thanks

    Read the article

  • Shortcuts and MSI updates

    - by Filip Navara
    We have an installer for application that is compiled using WiX and each version is updated using a new setup package. The installer creates advertised shortcut in Start menu and users often copy this shortcut to desktop or other location. During an application update a major upgrade is performed and the old shortcuts are removed, which causes the ones copied by users to disappear. This causes a major annoyance to the users. Is there a way to update advertised shortcuts when doing MSI major upgrade (ie. different product code)? Or, is there a way to allow minor updates by just running the setup.msi file (without passing a REINSTALLMODE option on the command line)? Or, is the only way to solve this problem to use non-advertised shortcuts?

    Read the article

  • Using WiX, how do I change a property of a subfolder of a virtual directory?

    - by Joergen Bech
    I have a hierarchy of Directory elements in a WiX script. I also have a component that creates a virtual directory (using IIS:WebVirtualDir), which points to the root of my Directory hierarchy. How do I change a property (e.g. AnonymousAccess) of a subfolder of the virtual directory, e.g. MyVirtualDir <<< this is the virtual directory root MyVirtualDir\MySubFolder <<< this is the subfolder for which I wish to change a property using WebDirProperties Please note that I do not wish to create a new virtual directory for the subfolder. I only wish to change a few security settings. The current script is too big to post here, but take a look at the WiX tutorial: 5.3 Web Directory. Suppose in that example that there was another Directory element named "MySubFolder" nested within the "InstallDir" element. What would then be the next step in order to set properties for "MySubFolder" without turning it into a virtual directory?

    Read the article

  • How can I launch an application as Administrator after a WiX MSI has completed?

    - by ray dey
    Hi there I want to launch an application with admin rights after I have completed an installation using a WiX based MSI. I can launch the application just fine, on XP but with Windows 7, it's an issue. The application has a manifest embedded in it that says it should run as administrator and I've changed the impersonate attribute in the Custom Action to "no". I can't change the execute attribute to deferred, as this only works before the InstallFinalize action and I need it after the user has clicked Finish in the MSI. This is my Custom Action: <CustomAction Id="LaunchApp" FileKey="App" ExeCommand="[Command Line Args]" Execute="immediate" Impersonate="no" Return="asyncNoWait" /> Any help on this would be appreciated. Thanks

    Read the article

  • How to make "msiexec /x" shortcut ask for elevation on XP?

    - by lonelyass
    On XP (user account) when running this shortcut: <Shortcut Id="UninstallStartMenuShortcut" Advertise="no" Name="AppName" Description="Uninstalls AppName" Target="[SystemFolder]msiexec.exe" Arguments="/x [ProductCode]"/> I'm getting an error "You must be an Administrator to remove this application. To remove this application, you can log on as an administrator, or contact your technical support group for assistance." Why this happens instead of asking for elevation with admin password? How can I avoid this stupid error?

    Read the article

  • Based on CheckBox value show the WIX Dialog.

    - by Velu
    I have instakllation i have to show the Dialog based on the checkbox value. I have set the checkbox property as true initially. <Property Id="CHECKBOX_1_PROP" Value="TRUE" /> And show the dialog based on the check box values. If it is true i have to show the Newdoalog_1 if it is false i have to show the Setup dialog INSTALL INSTALL AND CHECKBOX_1_PROP="TRUE" INSTALL INSTALL My Problem is always show the Setup Dialog that is False condition. Pls help on this.

    Read the article

  • WiX - How do I prevent ComPlusAssembly being unregistered during uninstall?

    - by Duncan Watts
    As part of my Installer, I am adding files to an existing COM+ package. I have defined a ComPlusApplication underneath my Product element, which has the name set to a property - I then have a custom action which looks up that property - all good so far. When the installer adds the files, within the same component I have added a ComPlusAssembly which adds the assembly to the ComPlusApplication I defined above - this is also working correctly. When uninstalled however, I am receiving an error related to being unable to find the COM+ application, this is because I am not running my custom action to look up the name of the COM+ package. Basically I do not want to remove my files or unregister the component package as part of the uninstallation process - How do I achieve this? I am using WiX 3.0 with VS2008. Thanks

    Read the article

  • [WiX] Is there a way to create a patch that is identical to doing a full install of the newer versio

    - by Davy8
    I'm trying to create patches using the method from this tutorial. An issue I'm running into is that I can't install a new patch on top of a previous patch. I can full install Version A,then patch to Version B. After that I can't patch to Version C. I can full install Version B, then patch to Version C. Currently we just do full installs with major updates each time which is working fine, but because of the frequency of our (internal) updates the file size and update time is becoming a burden so we're looking to reduce the update time (both downloading and installing) especially when most of the files don't change.

    Read the article

< Previous Page | 1 2 3  | Next Page >