Search Results

Search found 10859 results on 435 pages for 'raid controller'.

Page 21/435 | < Previous Page | 17 18 19 20 21 22 23 24 25 26 27 28  | Next Page >

  • Resize a RAID 1 volume on OS X Snow Leopard - how? (Note: software raid)

    - by Emmel
    I've scoured the Internet in search of an answer to this question, and as usual with OSX-related topics, I often don't find any deep-dive technical explanations sufficient enough to feel confident doing dangerous things. Here is my question: I have a Mac Pro, running OS X 10.6.2. I have, as my main root/boot disk, a RAID 1 volume called "Mirror1". Mirror1 is comprised of two 1 TB disks. Mirror1, however, is fixed at 640 GB. That's because, I originally took a 640GB disk, bought a terabyte disk, mirrored it (using diskutil appleraid enable), when it synced I removed the 640GB and replaced it with a second 1 TB disk, and synced again. Voila! A single 640 GB replaced by two 1 TB disks in a mirror.. Actually, no. There's still something missing from the equation: Mirror1 needs to be expanded from 640GB to 1 TB to match the partition sizes on each of those disks. How do I do this? Perhaps the diskutil output will help: -> diskutil list /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk0 1: EFI 209.7 MB disk0s1 2: Apple_RAID 999.9 GB disk0s2 3: Apple_Boot Boot OSX 134.2 MB disk0s3 /dev/disk1 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk1 1: EFI 209.7 MB disk1s1 2: Apple_RAID 999.9 GB disk1s2 3: Apple_Boot Boot OSX 134.2 MB disk1s3 /dev/disk2 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *640.1 GB disk2 1: EFI 209.7 MB disk2s1 2: Apple_HFS Mac Disk 2 536.7 GB disk2s2 3: Microsoft Basic Data BOOTCAMP 103.1 GB disk2s3 /dev/disk3 #: TYPE NAME SIZE IDENTIFIER 0: Apple_HFS Mirror1 *639.8 GB disk3 -> diskutil appleraid list AppleRAID sets (1 found) =============================================================================== Name: Macintosh HD Unique ID: 1953F864-B474-4EB6-8E69-41834EBD0247 Type: Mirror Status: Online Size: 639.8 GB (639791038464 Bytes) Rebuild: manual Device Node: disk3 ------------------------------------------------------------------------------- # Device Node UUID Status ------------------------------------------------------------------------------- 0 disk1s2 25109BAE-5697-40EA-B612-0217851444F7 Online 1 disk0s2 11B83AB0-8148-4DB6-8761-DEF08C855F8D Online =============================================================================== Thanks in advance.

    Read the article

  • effective back-up using Raid / Win7 back-up

    - by Job
    I have a stand-alone pc system with two 2 tb harddiscs, one of which configured as Raid1, i.e. mirorring. The operational drive is partitioned. I use an external 1 tb harddisc for back-up using Windows 7 back-up facility which will be swapped weekly and stored on other premises. I back-up all partitions AND allow a system back-up. All application software is on the C: partition. Questions: How can I see whether Raid1 is working; i.e. is doing its job. All I see now is a status message in the start-up procedure that says its status is normal. How can I see used or available space on Raid 1? The Win-7 backup allows for 1 schedule only as far as I can see. I want daily back-ups of data. However due to the single schedule I am forced to do the time-consuming system back-up and c: back-up as well. Is there a way to activate two schedules allowing a frequent (daily) data back-up and a system back-up with c: drive back-up on a say weekly basis? Of course it can be forced by hand but I am likely to forget that. I am not the programming type of person so looking for simple and controllable solutions. Thank you - any help is apreciated.

    Read the article

  • mkfs Operation Takes Very Long on Linux Software Raid 5

    - by Elmar Weber
    I've set-up a Linux software raid level 5 consisting of 4 * 2 TB disks. The disk array was created with a 64k stripe size and no other configuration parameters. After the initial rebuild I tried to create a filesystem and this step takes very long (about half an hour or more). I tried to create an xfs and ext3 filesystem, both took a long time, with mkfs.ext3 I observed the following behaviour, which might be helpful: writing inode tables runs fast until it reaches 1053 (~ 1 second), then it writes about 50, waits for two seconds, then the next 50 are written (according to the console display) when I try to cancel the operation with Control+C it hangs for half a minute before it is really canceled The performance of the disks individually is very good, I've run bonnie++ on each one separately with write / read values of around 95 / 110MB/s. Even when I run bonnie++ on every drive in parallel the values are only reduced by about 10 MB. So I'm excluding hardware / I/O scheduling in general as a problem source. I tried different configuration parameters for stripe_cache_size and readahead size without success, but I don't think they are that relevant for the file system creation operation. The server details: Linux server 2.6.35-27-generic #48-Ubuntu SMP x86_64 GNU/Linux mdadm - v2.6.7.1 Does anyone has a suggestion on how to further debug this?

    Read the article

  • Resize a RAID 1 volume on OSX Snow Leopard - how? (Note: software raid)

    - by Emmel
    I've scoured the Internet in search of an answer to this question, and as usual with OSX-related topics, I often don't find any deep-dive technical explanations sufficient enough to feel confident doing dangerous things. Here is my question: I have a Mac Pro, running OSX 10.6.2. I have, as my main root/boot disk, a RAID 1 volume called "Mirror1". Mirror1 is comprised of two 1 TB disks. Mirror1, however, is fixed at 640 GB. That's because, I originally took a 640GB disk, bought a terabyte disk, mirrored it (using diskutil appleraid enable...), when it synced I removed the 640GB and replaced it with a second 1 TB disk, and synced again. Voila! A single 640 GB replaced by two 1 TB disks in a mirror.. Actually, no. There's still something missing from the equation: Mirror1 needs to be expanded from 640GB to 1 TB to match the partition sizes on each of those disks. How do I do this? Perhaps the diskutil output will help: -> diskutil list /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk0 1: EFI 209.7 MB disk0s1 2: Apple_RAID 999.9 GB disk0s2 3: Apple_Boot Boot OSX 134.2 MB disk0s3 /dev/disk1 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk1 1: EFI 209.7 MB disk1s1 2: Apple_RAID 999.9 GB disk1s2 3: Apple_Boot Boot OSX 134.2 MB disk1s3 /dev/disk2 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *640.1 GB disk2 1: EFI 209.7 MB disk2s1 2: Apple_HFS Mac Disk 2 536.7 GB disk2s2 3: Microsoft Basic Data BOOTCAMP 103.1 GB disk2s3 /dev/disk3 #: TYPE NAME SIZE IDENTIFIER 0: Apple_HFS Mirror1 *639.8 GB disk3 -> diskutil appleraid list AppleRAID sets (1 found) =============================================================================== Name: Macintosh HD Unique ID: 1953F864-B474-4EB6-8E69-41834EBD0247 Type: Mirror Status: Online Size: 639.8 GB (639791038464 Bytes) Rebuild: manual Device Node: disk3 ------------------------------------------------------------------------------- # Device Node UUID Status ------------------------------------------------------------------------------- 0 disk1s2 25109BAE-5697-40EA-B612-0217851444F7 Online 1 disk0s2 11B83AB0-8148-4DB6-8761-DEF08C855F8D Online =============================================================================== Thanks in advance.

    Read the article

  • Showing login view controller before main tab bar controller

    - by Padawan
    I'm creating an iPad app with a tab bar controller that requires login. So on launch, I want to show a LoginViewController and if login is successful, then show the tab bar controller. This is how I implemented an initial test version (left out some typical header stuff, etc)... AppDelegate.h: @interface AppDelegate_Pad : NSObject <UIApplicationDelegate, LoginViewControllerDelegate> { UIWindow *window; UITabBarController *tabBarController; } @property (nonatomic, retain) IBOutlet UIWindow *window; @property (nonatomic, retain) IBOutlet UITabBarController *tabBarController; @end AppDelegate.m: @implementation AppDelegate_Pad @synthesize window; @synthesize tabBarController; - (BOOL)application:(UIApplication *)application didFinishLaunchingWithOptions:(NSDictionary *)launchOptions { LoginViewController_Pad *lvc = [[LoginViewController_Pad alloc] initWithNibName:@"LoginViewController_Pad" bundle:nil]; lvc.delegate = self; [window addSubview:lvc.view]; //[lvc release]; [window makeKeyAndVisible]; return YES; } - (void)loginViewControllerDidFinish:(LoginViewController_Pad *)loginViewController { [window addSubview:tabBarController.view]; } - (void)dealloc {...} @end LoginViewController_Pad.h: @protocol LoginViewControllerDelegate; @interface LoginViewController_Pad : UIViewController { id<LoginViewControllerDelegate> delegate; } @property (nonatomic, assign) id <LoginViewControllerDelegate> delegate; - (IBAction)buttonPressed; @end @protocol LoginViewControllerDelegate -(void)loginViewControllerDidFinish:(LoginViewController_Pad *)loginViewController; @end LoginViewController_Pad.m: @implementation LoginViewController_Pad @synthesize delegate; ... - (IBAction)buttonPressed { [self.view removeFromSuperview]; [self.delegate loginViewControllerDidFinish:self]; } ... @end So the app delegate adds the login view controller's view on launch and waits for login to call "did finish" using a delegate. The login view controller calls removeFromSuperView before it calls didFinish. The app delegate then calls addSubView on the tab bar controller's view. If you made it up to this point, thanks, and I have three questions: MAIN QUESTION: Is this the right way to show a view controller before the app's main tab bar controller is displayed? Even though it seems to work, is it a proper way to do it? If I comment out the "lvc release" in the app delegate then the app crashes with EXC_BAD_ACCESS when the button on the login view controller is pressed. Why? With the "lvc release" commented out everything seems to work but on the debugger console it writes this message when the app delegate calls addSubView for the tab bar controller: Using two-stage rotation animation. To use the smoother single-stage animation, this application must remove two-stage method implementations. What does that mean and do I need to worry about it?

    Read the article

  • MVC - Calling Controller Methods

    - by JT703
    Hello, My application is following the MVC design pattern. The problem I keep running into is needing to call methods inside a Controller class from outside that Controller class (ex. A View class wants to call a Controller method, or a Manager class wants to call a Controller method). Is calling Controller methods in this way allowed in MVC? If it's allowed, what's the proper way to do it? According to the version of MVC that I am following (there seems to be so many different versions out there), the View knows of the Model, and the Controller knows of the View. Doing it this way, I can't access the controller. Here's the best site I've found and the one describing the version of MVC I'm following: http://leepoint.net/notes-java/GUI/structure/40mvc.html. The Main Program code block really shows how this works. Thanks for any answers.

    Read the article

  • What does "single-bit ECC errors were detected on the RAID controller" mean?

    - by jsp
    I have a Dell T7600 with a Perc H710P RAID controller and 4 attached 3TB drives. Over the past few months the RAID controller has been intermittently reporting errors on boot: "no boot device found", "adapter at baseport is not responding", disks frequently reported as missing or failed. I have since replaced the RAID controller, the 4 hard drives, and finally the system's motherboard. After replacing the motherboard and rebooting a few times, I got the error Single bit ECC errors were detected on the RAID controller. Please contact technical support to resolve this issue. After rebooting about 20 more times, I haven't seen the ECC error. The system seems otherwise OK, except for the fact that the disk fans will sometimes start blowing at full blast when the the system is sitting completely idle and not stop until I reboot. Are the ECC errors in memory on the RAID controller? Or, does the RAID controller map in system memory, and the ECC errors are really in system memory? Or, are the ECC errors in the 1GB cache that resides in the RAID controller?

    Read the article

  • Dell Poweredge 1950 with Perc 5i keeps losing raid config -> "Foreign Configuration Found"

    - by nosage
    The quick and dirty: the machine is a Dell Poweredge 1950, dual xeon quad cores, 8GB of ram, 2 2TB seagate SATAs in (supposed to be raid1) using a Perc 5i raid card. They are hot-swappable with a back-plane. I can build the raid fine and after a little while an install of server 08 r2 will blue screen and restart. When it comes up the raid controller says "Foreign Configuration Found." When I go into the raid configuration panel there is no raid listed but I can import the "foreign config", and the OS will boot up fine, until it blue screens again after a little while. The issue is OS independent. I have tried swapping raid cards, swapping the RAM module on the raid card and swapping the raid battery, all to no avail. Its almost as if there is a loose connection from the raid card to the back plane and both of disks get lost and the raid card drops the config. But it sees the disks fine when it boots back up. The raid card uses a SCSI SAS cable to connect to the back-plane so I guess the next step is to replace that, but... then I might as well replace the back-plane with a SCSI SAS to sata breakout cable, but... then I need a way to power the disks. Sorry for the wall of txt but it would be great to get some thoughts from people who worked with perc raid cards or poweredge servers with this type of issue before. Ironically I want to get this system up and running so I can work on MCITP labs. Thank you for any/all help and feel free to ask questions!

    Read the article

  • CentOS - mdadm raid1 drive won't mount to default location

    - by danny
    I'm running CentOS 5.5, the system, boot, swap, etc. is all on /dev/sda and I have two identical single-partition drives /dev/sdb1 /dev/sdc1 that are configured in RAID1 (using mdadm). It was working fine (configured to mount to /mnt/data in the fstab file) and I recently let yum install a couple of automatic updates without paying attention to what they were, and now it doesn't work. Raid is working fine (dmesg shows it gets loaded correctly). mdstat shows: # cat /proc/mdstat Personalities : [raid1] md0 : active raid1 sdc1[1] sdb1[0] XXXX blocks [2/2] [UU] unused devices: <none> Additionally, I can mount it anywhere other than its default directory (i.e. the following works, and I can read data off the drives). # mount /dev/md0 /mnt/data2 EXT3-fs warning: mounting fs with errors, running e2fsck is recommended But when I run the following I get: # mount -a mount: /dev/sdb1 already mounted or /mnt/data busy It says nothing is mounted when I try to umount /dev/sdb1 or umount /mnt/data, so I assume it's the second of those errors. However, lsof | grep mnt shows nothing. The weird thing is that I can save files in /mnt/data. So something is obviously mounted there, but when I try to umount it I get the error that nothing is mounted. /etc/mtab doesn't mention any of the partitions or files I am trying to work with, and fstab just has that one line I mentioned above that is supposed to mount my raid partition. Again, it was all working fine until I On Google I've found a few things about dmraid interfering with mdadm after an update, but I yum remove'd dmraid and rebooted and it didn't help. I'm really confused and need to get this working to get on with my work!

    Read the article

  • Western Digital My Book not recognized by WD software

    - by Kari
    A few years ago I bought a WD My Book Pro 2. It worked fine for a while, then one of the drives failed and I sent it back to be replaced under warranty. I never got around to setting up the new one when I got it back. I finally ran out of room on my internal drive, so I tried to use the external - no go. Both drives spin up, but aren't recognized by either Disk Utility (Mac) or the WD Drive Manager. I tried on a PC as well with fresh software. Then I pulled the drives out of the enclosure (warranty is already expired) and plugged them straight into the PC. Both recognized and working 100% in RAID0. BIOS recognizes either disk as functional; Windows only sees them when both are connected due to the RAID which I can't change without the WD software. The drives that were returned to me are the "Green" drives which I've read are NOT recommended for RAID. Is it possible that this is interfering with them reading externally? Any other ideas? My main computer is a laptop so using them internally isn't an option :(

    Read the article

  • Western Digital My Book not recognized by WD software

    - by Kari
    A few years ago I bought a WD My Book Pro 2. It worked fine for a while, then one of the drives failed and I sent it back to be replaced under warranty. I never got around to setting up the new one when I got it back. I finally ran out of room on my internal drive, so I tried to use the external - no go. Both drives spin up, but aren't recognized by either Disk Utility (Mac) or the WD Drive Manager. I tried on a PC as well with fresh software. Then I pulled the drives out of the enclosure (warranty is already expired) and plugged them straight into the PC. Both recognized and working 100% in RAID0. BIOS recognizes either disk as functional; Windows only sees them when both are connected due to the RAID which I can't change without the WD software. The drives that were returned to me are the "Green" drives which I've read are NOT recommended for RAID. Is it possible that this is interfering with them reading externally? Any other ideas? My main computer is a laptop so using them internally isn't an option :(

    Read the article

  • Restored Domain Controller does not display any information using dcdiag command

    - by dasko
    I am testing restoring a domain controller from system state backup to different hardware in a non production environment as a sanity check for our restoration procedure. When i run the dcdiag command I get "blank info back" and all that is displayed are two lines as follows: Domain Controller Diagnosis Performing initial setup: and then I am returned to the command prompt. Even when I do dcdiag /v i get the same result. I have double checked the DNS settings and Active Directory works properly. All FSMO roles are being held by this restored Domain Controller. I am able to join test pc's to the domain without issue etc Is this a common issue or is there something that I am missing. Thanks.

    Read the article

  • Intel SASWT4I SAS/SATA Controller Question

    - by Joe Hopfgartner
    Hey there! I want to assemble a cheap storage sytem based on the Norco RPC-4020 Case. When searching for controllers I found this one: Intel® RAID Controller SASWT4I This is a quote form the Spec Sheet: Scalability. Supports up to 122 physical devices in SAS mode which is ideal for employing JBODs (Just a Bunch Of Disks) or up to 14 devices in RAID 0, 1, 1E/10E mode through direct connect device attachment or through expander backplane support. Does that mean I can attatch 14 SATA drives directly to the controller using SFF-8087 - 4x SATA breakout cables? That would be nice because then I can choose a mainboard that has 6 Onboard SATA and i can connect all 20 bays while only spending 155$ on the controller and like another 100$ on cables. Would that work? And why is it 14 and not 16 when there are 4 Ports? I am really confused about all the breakout/fanout/(edge-)expanding/multiplying/channel stuff...

    Read the article

  • Controller Action Methods with different signatures

    - by Narsil
    I am trying to get my URLs in files/id format. I am guessing I should have two Index methods in my controller, one with a parameter and one with not. But I get this error message in browser below. Anyway here is my controller methods: public ActionResult Index() { return Content("Index "); } // // GET: /Files/5 public ActionResult Index(int id) { File file = fileRepository.GetFile(id); if (file == null) return Content("Not Found"); else return Content(file.FileID.ToString()); } Error: Server Error in '/' Application. The current request for action 'Index' on controller type 'FilesController' is ambiguous between the following action methods: System.Web.Mvc.ActionResult Index() on type FileHosting.Controllers.FilesController System.Web.Mvc.ActionResult Index(Int32) on type FileHosting.Controllers.FilesController Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Reflection.AmbiguousMatchException: The current request for action 'Index' on controller type 'FilesController' is ambiguous between the following action methods: System.Web.Mvc.ActionResult Index() on type FileHosting.Controllers.FilesController System.Web.Mvc.ActionResult Index(Int32) on type FileHosting.Controllers.FilesController Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Stack Trace: [AmbiguousMatchException: The current request for action 'Index' on controller type 'FilesController' is ambiguous between the following action methods: System.Web.Mvc.ActionResult Index() on type FileHosting.Controllers.FilesController System.Web.Mvc.ActionResult Index(Int32) on type FileHosting.Controllers.FilesController] System.Web.Mvc.ActionMethodSelector.FindActionMethod(ControllerContext controllerContext, String actionName) +396292 System.Web.Mvc.ReflectedControllerDescriptor.FindAction(ControllerContext controllerContext, String actionName) +62 System.Web.Mvc.ControllerActionInvoker.FindAction(ControllerContext controllerContext, ControllerDescriptor controllerDescriptor, String actionName) +13 System.Web.Mvc.ControllerActionInvoker.InvokeAction(ControllerContext controllerContext, String actionName) +99 System.Web.Mvc.Controller.ExecuteCore() +105 System.Web.Mvc.ControllerBase.Execute(RequestContext requestContext) +39 System.Web.Mvc.ControllerBase.System.Web.Mvc.IController.Execute(RequestContext requestContext) +7 System.Web.Mvc.<c_DisplayClass8.b_4() +34 System.Web.Mvc.Async.<c_DisplayClass1.b_0() +21 System.Web.Mvc.Async.<c__DisplayClass81.<BeginSynchronous>b__7(IAsyncResult _) +12 System.Web.Mvc.Async.WrappedAsyncResult1.End() +59 System.Web.Mvc.MvcHandler.EndProcessRequest(IAsyncResult asyncResult) +44 System.Web.Mvc.MvcHandler.System.Web.IHttpAsyncHandler.EndProcessRequest(IAsyncResult result) +7 System.Web.CallHandlerExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute() +8677678 System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously) +155 Updated Code: public ActionResult Index(int? id) { if (id.HasValue) { File file = fileRepository.GetFile(id.Value); if (file == null) return Content("Not Found"); else return Content(file.FileID.ToString()); } else return Content("Index"); } It's still not the thing I want. URLs have to be in files?id=3 format. I want files/3 routes from global.asax routes.MapRoute( "Default", // Route name "{controller}/{action}/{id}", // URL with parameters new { controller = "Home", action = "Index", id = UrlParameter.Optional } // Parameter defaults ); //files/3 //it's the one I wrote routes.MapRoute("Files", "{controller}/{id}", new { controller = "Files", action = "Index", id = UrlParameter.Optional} ); I tried adding a new route after reading Jeff's post but I can't get it working. It still works with files?id=2 though.

    Read the article

  • Integrating Zend Controller Standalone - without the rest of Zend Framework

    - by ssmusoke
    I am using specific parts of the Zend Framework in my application, and I would like to replace my home grown controller with a Zend Framework controller. My home grown controller is based on an index.php file to which all requests are submitted. A controller is instantiated based on parameters sent within the request After processing the user is forwarded to url which is based on the request information, either a url is specified or some data is analysed I would like ideas on how to integrate the Zend Controller within my application Thanks in advance

    Read the article

  • How can I fix my corrupted RAID1 ext4 partition on a Synology DS212 NAS?

    - by Neil
    I have two identical 3 TB disks that were in a RAID1 array, where one disk crashed. I replaced the failed disk, but not after the RAID partitions got messed up. I need to figure out how to restore the RAID array and get at my ext4 partition. Here are the properties of the surviving disk: # fdisk -l /dev/sda fdisk: device has more than 2^32 sectors, can't use all of them Disk /dev/sda: 2199.0 GB, 2199023255040 bytes 255 heads, 63 sectors/track, 267349 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/sda1 1 267350 2147483647+ ee EFI GPT # parted /dev/sda print Model: ATA ST3000DM001-9YN1 (scsi) Disk /dev/sda: 3001GB Sector size (logical/physical): 512B/512B Partition Table: gpt Disk Flags: Number Start End Size File system Name Flags 1 131kB 2550MB 2550MB ext4 raid 2 2550MB 4698MB 2147MB linux-swap(v1) raid 5 4840MB 3001GB 2996GB raid I replaced the failed drive, and cloned the surviving drive to it so I have something to work with. I cloned the drives with dd if=/dev/sdb of=/dev/sda conv=noerror bs=64M, and now /dev/sda and /dev/sdb are identical. Here is the RAID information: # cat /proc/mdstat Personalities : [linear] [raid0] [raid1] [raid10] [raid6] [raid5] [raid4] md1 : active raid1 sdb2[1] 2097088 blocks [2/1] [_U] md0 : active raid1 sdb1[1] 2490176 blocks [2/1] [_U] unused devices: <none> It seems that md2 is missing. Here is what testdisk 6.14-WIP finds: Disk /dev/sda - 3000 GB / 2794 GiB - CHS 364801 255 63 Current partition structure: Partition Start End Size in sectors 1 P Linux Raid 256 4980735 4980480 [md0] 2 P Linux Raid 4980736 9175039 4194304 [md1] Invalid RAID superblock 5 P Linux Raid 9453280 5860519007 5851065728 5 P Linux Raid 9453280 5860519007 5851065728 # After a quick search Disk /dev/sda - 3000 GB / 2794 GiB - CHS 364801 255 63 Partition Start End Size in sectors D MS Data 256 4980607 4980352 [1.41.12-2197] D Linux Raid 256 4980735 4980480 [md0] D Linux Swap 4980736 9174895 4194160 D Linux Raid 4980736 9175039 4194304 [md1] >P MS Data 9481056 5858437983 5848956928 [1.41.12-2228] And listing the files on the last partition in the list shows all of my files intact. What should I do?

    Read the article

  • Just re-installed Ubuntu 14.04, unstable wireless connection, Lenovo ThinkPad X200

    - by Mark Lawtie
    I re-installed Ubuntu 14.04 as I was having problems with unstable wireless connection... Following re-installation I am having the same problem: connection randomly dropping out, then reconnecting... all my other devices are running well when connected I am a bit of a computer novice so any help would be greatly appreciated... I am running Lenovo ThinkPad X200 laptop... Thanks! mark@mark-ThinkPad-X200:~$ lspci 00:00.0 Host bridge: Intel Corporation Mobile 4 Series Chipset Memory Controller Hub (rev 07) 00:02.0 VGA compatible controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:02.1 Display controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:03.0 Communication controller: Intel Corporation Mobile 4 Series Chipset MEI Controller (rev 07) 00:19.0 Ethernet controller: Intel Corporation 82567LM Gigabit Network Connection (rev 03) 00:1a.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #4 (rev 03) 00:1a.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #5 (rev 03) 00:1a.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #6 (rev 03) 00:1a.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #2 (rev 03) 00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) 00:1c.0 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 1 (rev 03) 00:1c.1 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 2 (rev 03) 00:1c.3 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 4 (rev 03) 00:1d.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #1 (rev 03) 00:1d.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #2 (rev 03) 00:1d.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #3 (rev 03) 00:1d.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #1 (rev 03) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev 93) 00:1f.0 ISA bridge: Intel Corporation ICH9M-E LPC Interface Controller (rev 03) 00:1f.2 SATA controller: Intel Corporation 82801IBM/IEM (ICH9M/ICH9M-E) 4 port SATA Controller [AHCI mode] (rev 03) 00:1f.3 SMBus: Intel Corporation 82801I (ICH9 Family) SMBus Controller (rev 03) 03:00.0 Network controller: Intel Corporation PRO/Wireless 5100 AGN [Shiloh] Network Connection mark@mark-ThinkPad-X200:~$ mark@mark-ThinkPad-X200:~$ lsusb Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 008 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 007 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 026: ID 0a5c:2145 Broadcom Corp. BCM2045B (BDC-2.1) [Bluetooth Controller] Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub mark@mark-ThinkPad-X200:~$

    Read the article

  • Wifi problems with Ubuntu 13.10

    - by Sparrowhawk4
    I should probably say straight off that I am brand new to Ubuntu. I installed 13.10 alongside Windows 7 a couple of days ago and I've managed to clear up all the little problems, apart from with the wifi. My internet is fine using an ethernet cable. I can connect to the wifi, and it tells me that the signal is good, but for the vast majority of the time I can't load anything, and system monitor tells me that I am sending and receiving nothing. The problem is somewhere in Ubuntu. It works fine on Windows 7, my Android phone and all of my flatmates laptops. I know I'm not the only one with this problem, but the fixes I've seen either don't work or I don't understand them enough to carry them out. Help? EDIT: from lspci command as requested 00:00.0 Host bridge: Intel Corporation Mobile 4 Series Chipset Memory Controller Hub (rev 07) 00:02.0 VGA compatible controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:02.1 Display controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:1a.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #4 (rev 03) 00:1a.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #5 (rev 03) 00:1a.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #2 (rev 03) 00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) 00:1c.0 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 1 (rev 03) 00:1c.1 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 2 (rev 03) 00:1d.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #1 (rev 03) 00:1d.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #2 (rev 03) 00:1d.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #3 (rev 03) 00:1d.3 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #6 (rev 03) 00:1d.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #1 (rev 03) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev 93) 00:1f.0 ISA bridge: Intel Corporation ICH9M LPC Interface Controller (rev 03) 00:1f.2 SATA controller: Intel Corporation 82801IBM/IEM (ICH9M/ICH9M-E) 4 port SATA Controller [AHCI mode] (rev 03) 00:1f.3 SMBus: Intel Corporation 82801I (ICH9 Family) SMBus Controller (rev 03) 00:1f.6 Signal processing controller: Intel Corporation 82801I (ICH9 Family) Thermal Subsystem (rev 03) 02:00.0 Network controller: Realtek Semiconductor Co., Ltd. RTL8191SEvA Wireless LAN Controller (rev 10) 03:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8101E/RTL8102E PCI Express Fast Ethernet controller (rev 02)

    Read the article

  • Will this RAID5 setup work (3TB Seagate Barracudas + Adaptec RAID 6405)?

    - by Slayer537
    As the title states, will this RAID combo work, and if not what needs to be changed? Overall opinions would be most helpful. I currently run a small file server of about 5TB or so. I keep outgrowing my needs and need to build a RAID setup that will allow me to expand as needed. I am new to RAID setups, especially one of the scale I have currently planned out, but I have being doing some research for the past couple of weeks and have come up with a build. Ideally, I'd have the setup completely built, but I'd like to keep the total cost around $1k and can't afford to go above $1.5k, so unfortunately that's not an option. 2 of my current drives are WD Caviar Blacks 2TB; however, I have recently learned that due to the lack of TLER those drives are awful for any RAID setup other than 0 or 1. That being said, my third drive is a Seagate Barracuda 3TB (ST300DM001) and I have found a RAID controller that states it supports it, so I'd like to use this same type of drive, if possible. Have any of you had any experience using this drive or a similar one in a RAID5 configuration? The manufacturer states that it supports it, but knowing that it is not an enterprise drive, I am slightly concerned that it could drop out of the array. I would just go with enterprise drives, but those are about double in cost... Parts list: Storage rack: http://www.ebay.com/itm/SGI-3U-Media-Storage-Server-16-Hard-Drive-Bay-SATA-SAS-Expander-Omnistor-SE3016-/140735776937?pt=LH_DefaultDomain_0&hash=item20c48188a9 3 more HDs (for now..): http://www.amazon.com/Seagate-Barracuda-3-5-Inch-Internal-ST3000DM001/dp/B005T3GRLY/ref=dp_return_2?ie=UTF8&n=172282&s=electronics Adaptec RAID 6405: http://www.newegg.com/Product/Product.aspx?Item=N82E16816103224 here's a link to the compatibility sheet if that helps: http://download.adaptec.com/pdfs/compatibility_report/arc-sas_cr_03-27-12_series6.pdf SAS expander cable: http://www.pc-pitstop.com/sas_cables_adapters/8887-2M.asp My plan is to install the RAID card in my computer and then route the SAS cable to the rack. Setup a RAID5 on 3 drives, transfer my data over from my other drive, and then add that drive to the array. Eventually, I'd like to get a 2U unit and run the file server on that and move the RAID card over to there, but that will have to happen later on. Side note: The computer the card would be going into will be running Windows 7 Pro with 24GB of DDR3-1600 and an i7-930.

    Read the article

  • How do I tell mdadm to start using a missing disk in my RAID5 array again?

    - by Jon Cage
    I have a 3-disk RAID array running in my Ubuntu server. This has been running flawlessly for over a year but I was recently forced to strip, move and rebuild the machine. When I had it all back together and ran up Ubuntu, I had some problems with disks not being detected. A couple of reboots later and I'd solved that issue. The problem now is that the 3-disk array is showing up as degraded every time I boot up. For some reason it seems that Ubuntu has made a new array and added the missing disk to it. I've tried stopping the new 1-disk array and adding the missing disk, but I'm struggling. On startup I get this: root@uberserver:~# cat /proc/mdstat Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md_d1 : inactive sdf1[2](S) 1953511936 blocks md0 : active raid5 sdg1[2] sdc1[3] sdb1[1] sdh1[0] 2930279808 blocks level 5, 64k chunk, algorithm 2 [4/4] [UUUU] I have two RAID arrays and the one that normally pops up as md1 isn't appearing. I read somewhere that calling mdadm --assemble --scan would re-assemble the missing array so I've tried first stopping the existing array that ubuntu started: root@uberserver:~# mdadm --stop /dev/md_d1 mdadm: stopped /dev/md_d1 ...and then tried to tell ubuntu to pick the disks up again: root@uberserver:~# mdadm --assemble --scan mdadm: /dev/md/1 has been started with 2 drives (out of 3). So that's started md1 again but it's not picking up the disk from md_d1: root@uberserver:~# cat /proc/mdstat Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md1 : active raid5 sde1[1] sdf1[2] 3907023872 blocks level 5, 64k chunk, algorithm 2 [3/2] [_UU] md_d1 : inactive sdd1[0](S) 1953511936 blocks md0 : active raid5 sdg1[2] sdc1[3] sdb1[1] sdh1[0] 2930279808 blocks level 5, 64k chunk, algorithm 2 [4/4] [UUUU] What's going wrong here? Why is Ubuntu trying to pick up sdd into a different array? How do I get that missing disk back home again? [Edit] - After adding the md1 to mdadm.conf it now tries to mount the array on startup but it's still missing the disk. If I tell it to try and assemble automatically I get the impression it know it needs sdd but can't use it: root@uberserver:~# mdadm --assemble --scan /dev/md1: File exists mdadm: /dev/md/1 already active, cannot restart it! mdadm: /dev/md/1 needed for /dev/sdd1... What am I missing?

    Read the article

  • zend framework controller not found ?

    - by user284503
    I downloaded the latest version of Zend framework, added a controller and I can not get it to load.. Here is what I did: C:\zend\Apache2\htdocs>zf create project myproject Creating project at C:/zend/Apache2/htdocs/myproject Note: This command created a web project, for more information setting up your V HOST, please see docs/README C:\zend\Apache2\htdocs>cd myproject C:\zend\Apache2\htdocs\myproject>zf create controller mycontroller Note: The canonical controller name that is used with other providers is "Mycont roller"; not "mycontroller" as supplied Creating a controller at C:\zend\Apache2\htdocs\myproject/application/controller s/MycontrollerController.php Creating an index action method in controller Mycontroller Creating a view script for the index action method at C:\zend\Apache2\htdocs\myp roject/application/views/scripts/mycontroller/index.phtml Creating a controller test file at C:\zend\Apache2\htdocs\myproject/tests/applic ation/controllers/MycontrollerControllerTest.php Updating project profile 'C:\zend\Apache2\htdocs\myproject/.zfproject.xml' C:\zend\Apache2\htdocs\myproject> Then I tried to hit the controller from the browser.. http://localhost/myproject/public/mycontroller/ and I get the error: Not Found The requested URL /myproject/public/mycontroller/ was not found on this server. I have no idea how to resolve this, and I'm sort of shocked I'm having problems with the Zend Server.

    Read the article

  • Rails exit controller after rendering

    - by codysehl
    I have an action in my controller that I am having trouble with. This is my first rails app, so I'm not sure of the best practices surrounding rails. I have a model called Group and a few actions that go in it's controller. I have written a test that should cause the controller to render an error in JSON because of an invalid Group ID. Instead of rendering and exiting, it looks like the controller is rendering and continuing to execute. Test test 'should not remove group because of invalid group id' do post(:remove, {'group_id' => '3333'}) response = JSON.parse(@response.body) assert_response :success assert_equal 'Success', response['message'] end Controller action # Post remove # group_id def remove if((@group = Group.find_by_id(params[:group_id])) == nil) render :json => { :message => "group_id not found" } end @group.destroy if(!Group.exists?(@group)) render :json => { :message => "Success" } else render :json => { :errors => @group.errors.full_messages } end end In the controller, the first if statement executes: render :json => { :message => "group_id not found" } but @group.destroy is still being executed. This seems counter-intuitive to me, I would think that the render method should exit the controller. Why is the controller not exiting after render is called? The purpose of this block of code is to recover gracefully when no record can be found with the passed in ID. Is this the correct way of doing something like this?

    Read the article

  • Realtek RTL8111/8168B wired network doesn't work anymore

    - by Radar4002
    This sounds like it's a common problem upgrading 11.04, but I am having trouble finding a common solution, and one that will work for me. I just applied updates via the update manager and now my wired network connection is down. I know Ubuntu network settings is the issue, because I have a dual-boot with Win 7 and my network/internet is fine on Win 7. I don't know too much about networking, so what can I do to trouble shoot this issue? I can choose an older grub version, 2.6.38-8 instead of 2.6.38-11 and this does not resolve the issue. Here is my lspci result: 00:00.0 Host bridge: ATI Technologies Inc RD890 Northbridge only single slot PCI-e GFX Hydra part (rev 02) 00:02.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port B) 00:04.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port D) 00:05.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port E) 00:06.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port F) 00:07.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port G) 00:09.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port H) 00:0a.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (external gfx1 port A) 00:11.0 SATA controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 SATA Controller [IDE mode] (rev 40) 00:12.0 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI0 Controller 00:12.2 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB EHCI Controller 00:13.0 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI0 Controller 00:13.2 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB EHCI Controller 00:14.0 SMBus: ATI Technologies Inc SBx00 SMBus Controller (rev 41) 00:14.1 IDE interface: ATI Technologies Inc SB7x0/SB8x0/SB9x0 IDE Controller (rev 40) 00:14.2 Audio device: ATI Technologies Inc SBx00 Azalia (Intel HDA) (rev 40) 00:14.3 ISA bridge: ATI Technologies Inc SB7x0/SB8x0/SB9x0 LPC host controller (rev 40) 00:14.4 PCI bridge: ATI Technologies Inc SBx00 PCI to PCI Bridge (rev 40) 00:14.5 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI2 Controller 00:15.0 PCI bridge: ATI Technologies Inc Device 43a0 00:16.0 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI0 Controller 00:16.2 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB EHCI Controller 00:18.0 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor HyperTransport Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor Miscellaneous Control 00:18.4 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor Link Control 01:00.0 VGA compatible controller: ATI Technologies Inc Juniper [Radeon HD 5700 Series] 01:00.1 Audio device: ATI Technologies Inc Juniper HDMI Audio [Radeon HD 5700 Series] 02:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 03) 05:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 03) 06:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 03) 07:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 07:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 08:0e.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) Here is my sudo lshw -class network: *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:05:00.0 logical name: eth0 version: 03 serial: 6c:f0:49:e7:72:e8 size: 10Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:40 ioport:9e00(size=256) memory:fceff000-fcefffff memory:fcef8000-fcefbfff memory:fce00000-fce1ffff *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:06:00.0 logical name: eth1 version: 03 serial: 6c:f0:49:e7:72:ea size: 10Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:47 ioport:8e00(size=256) memory:fddff000-fddfffff memory:fddf8000-fddfbfff memory:fdd00000-fdd1ffff

    Read the article

  • Proliant server will not accept new hard disks in RAID 1+0?

    - by Leigh
    I have a HP ProLiant DL380 G5, I have two logical drives configured with RAID. I have one logical drive RAID 1+0 with two 72 gb 10k sas 1 port spare no 376597-001. I had one hard disk fail and ordered a replacement. The configuration utility showed error and would not rebuild the RAID. I presumed a hard disk fault and ordered a replacement again. In the mean time I put the original failed disk back in the server and this started rebuilding. Currently shows ok status however in the log I can see hardware errors. The new disk has come and I again have the same problem of not accepting the hard disk. I have updated the P400 controller with the latest firmware 7.24 , but still no luck. The only difference I can see is the original drive has firmware 0103 (same as the RAID drive) and the new one has HPD2. Any advice would be appreciated. Thanks in advance Logs from server ctrl all show config Smart Array P400 in Slot 1 (sn: PAFGK0P9VWO0UQ) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 1, Interim Recovery Mode) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 73.5 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, Failed array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK) ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAFGK0P9VWO0UQ Cache Serial Number: PA82C0J9VWL8I7 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: E Firmware Version: 7.24 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Status Details: A cache error was detected. Run more information. Cache Ratio: 100% Read / 0% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: Failed Physical Drive Array Type: Data One of the drives on this array have failed or has Logical Drive: 1 Size: 68.5 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17594 Strip Size: 128 KB Full Stripe Size: 128 KB Status: Interim Recovery Mode Caching: Enabled Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive0 Mount Points: C:\ 68.5 GB Logical Drive Label: A0100539PAFGK0P9VWO0UQ0E93 Mirror Group 0: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, S Mirror Group 1: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, S Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 73.5 GB Rotational Speed: 10000 Firmware Revision: 0103 Serial Number: B379P8C006RK Model: HP DG072A9B7 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: Failed Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: D5A1PCA04SL01244 Model: HP EH0072FARUA PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data Logical Drive: 2 Size: 558.7 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Co Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive1 Mount Points: E:\ 558.7 GB Logical Drive Label: AF14FD12PAFGK0P9VWO0UQD007 Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE07QH300009923X1X3 Model: HP DG0300BALVP Current Temperature (C): 32 Maximum Temperature (C): 45 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE0AHVH00009924P8F3 Model: HP DG0300BALVP Current Temperature (C): 34 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE08NAK00009924KWD6 Model: HP DG0300BALVP Current Temperature (C): 35 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown

    Read the article

  • PS3 controller -> PC -> emulators -> TV

    - by abrereton
    I'm researching a media PC for the living room. Playing videos, audio and streaming Internet is straightforward enough. I would also like to run a gaming console system. I was wondering if anyone has any thoughts on this. So far I've discovered that a PS3 controller (thankfully it uses USB and Bluetooth) can be connected to a PC. I've also found that MAME, MESS and PCSX2 are all the emulators I need (I can even emulate a TI-83 calculator with MESS). These emulators can re-map keys, so for example I can make the Nintendo's A button to the PS3 X button, or the SNES key pad could be the PS3 keypad or the analog stick. There are also front-ends to these emulators which can do fancy things like image scaling, anti-aliasing and double-buffering to improve the image quality of an 8-bit Mario on a 50 inch plasma. My set up would be this: PS3 controller connecting over Bluetooth to the PC, PC with Windows, PS3 controller drivers, all my emulators, Network drive with all my ROMs, PC connected to TV via HDMI TV playing Super Mario Kart Does this sound feasible? Does anyone have experience of doing anything like this? Is this a good idea or should I grow up and stop living in the past?

    Read the article

< Previous Page | 17 18 19 20 21 22 23 24 25 26 27 28  | Next Page >