Search Results

Search found 51569 results on 2063 pages for 'version number'.

Page 21/2063 | < Previous Page | 17 18 19 20 21 22 23 24 25 26 27 28  | Next Page >

  • Deleting Large Number of Records

    Often someone will try to perform a delete on a large number of records and run into a number of problems. Slow performance, log growth, and more. Lynn Pettis shows us how to better handle this situation in SQL Server 2000 and SQL Server 2005 The Future of SQL Server Monitoring "Being web-based, SQL Monitor 2.0 enables you to check on your servers from almost any location" Jonathan Allen.Try SQL Monitor now.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Ad Hoc Distribution - Does it update an existing previous installed version of an app?

    - by Kriem
    What happens when a user installs an ad hoc distribution of an existing app? And what happens if this app (or a newer one) hits the App Store officially? To sum it up: A user already has a v1.0 and receives a v2.0 ad hoc A user has the ad hoc v2.0 and the official public release of v2.0 hits the store A user has the ad hoc v2.0 and an official public release of v3.0 hits the store In other words, is the ad hoc version a stand-alone build or does it in fact update a previous version as expected from an update? And will it be updated as soon as a newer version hits the store?

    Read the article

  • Why avoid pessimistic locking in a version control system?

    - by raven
    Based on a few posts I've read concerning version control, it seems people think pessimistic locking in a version control system is a bad thing. Why? I understand that it prevents one developer from submitting a change while another has the file checked out, but so what? If your code files are so big that you constantly have more than one person working on them at the same time, I submit that you should reorganize your code. Break it up into smaller functional units. Integration of concurrent code changes is a tedious and error-prone process even with the tools a good version control system provides to make it easier. I think it should be avoided if at all possible. So, why is pessimistic locking discouraged?

    Read the article

  • Maven 2: How to package current project version in a WAR file?

    - by Tom van Zummeren
    I am using Maven 2 to build my Java project and I am looking for a way to present the current version number of the pom.xml to the user (using a Servlet or JSP for example). As far as I can see, the best way would be that Maven packages the version number as a text file into the WAR. This allows me to read the version from that file and present it the way I want. Does anyone know of a plugin that can do something like that for me? Maybe the WAR plugin can be configured to do so? Or maybe using some other approach all together?

    Read the article

  • Naming the implementation version of an interface function

    - by bolov
    When I need to write an implementation version of an interface function, I put the implementation function within a impl namespace, but with the same name as the interface function. Is this a bad practice? (the same name part, the namespace part I am confident it’s more than OK). For me, who I write the code, there is no confusion between the two, but I want to make sure this isn’t confusing for someone else. One other option would be to append impl suffix to the function name, but since it is already in a separate namespace named impl it seems redundant. Is there an idiomatic way to do this? E.g.: namespace n { namespace impl { // implementation function (hidden from users) // same name, is it ok? void foo() { // ... //sometimes it needs to call recursively or to call overloads of the interface version: foo(); // calls the implementation version. Is this confusing? n::foo(); // calls the interface version. Is this confusing? // ... } // namespace impl // interface function (exposed to users) void foo() { impl::foo(); } } // namespace n

    Read the article

  • Hack Extension Files to Make Them Version-Compatible for Firefox

    - by Asian Angel
    A well known drawback in using Firefox is the problem with extension compatibility when a new major version is released. Whether it is for a new extension that you are trying for the first time or an old favorite we have a way to get those extensions working for you again. There are multiple reasons why you might want to choose this method to fix a non-compatible extension: You are uncomfortable with tweaking the “about:config” settings You prefer to maintain the original “about:config” settings in a pristine state and like having compatibility checking active You are looking to gain some “geek cred” Keep in mind that most extensions will work perfectly well with a new version of Firefox and simply have the “version compatibility number” problem. But once in a while there may be one that needs to have some work done on it by the extension’s author. The Problem Here is a perfect example of everyone’s least favorite “extension message”. This is the last thing that you need when all that you want is for your favorite extension (or a new one) to work on a fresh clean install. Note: This works nicely to “replace” non-compatible extensions already present in your browser if you are simply upgrading. Hacking the XPI File For this procedure you will need to manually download the extension to your hard-drive (right click on the extension’s “Install Button” and select “Save As”). Once you have done that you are ready to start hacking the extension. For our example we chose the “GCal Popup Extension”. The best thing to do is place the extension in a new folder (i.e. the Desktop or other convenient location) then unzip it just the same way that you would with any regular zip file. Once it is unzipped you will see the various folders and files that were in the “xpi file” (we had four files here but depending on the extension the number may vary). There is only one file that you need to focus on…the “install.rdf” file. Note: At this point you should move the original extension file to a different location (i.e. outside of the folder) so that it is no longer present. Open the file in “Notepad” so that you can change the number for the “maxVersion”. Here the number is listed as “3.5.*” but we needed to make it higher… Replacing the “5” with a “7” is all that we needed to do. Once you have entered your new “maxVersion” number save the file. At this point you will need to re-zip all of the files back into a single file. Make certain that you “create” a file with the “.zip file extension” otherwise this will not work. Once you have the new zip file created you will need to rename the entire file including the “file extension”. For our example we copied and pasted the original extension name. Once you have changed the name click outside of the “text area”. You will see a small message window like this asking for confirmation…click “Yes” to finish the process. Now your modified/updated extension is ready to install. Drag the extension into your browser to install it and watch that wonderful “Restart to complete the installation.” message appear. As soon as your browser starts you can check the “Add-ons Manager Window” and see the version compatibility numbers for the extension. Looking very very nice! And just like that your extension should be up and running without any problems. Conclusion If you are looking to try something new, gain some geek cred, or just want to keep your Firefox install as close to the original condition as possible this method should get those extensions working nicely for you again. Similar Articles Productive Geek Tips Make Firefox Extensions Compatible After Firefox Update Breaks Them For No Good ReasonCheck Extension Compatibility for Upcoming Firefox ReleasesFirefox 3.6 Release Candidate Available, Here’s How to Fix Your Incompatible ExtensionsHow To Force Extension Compatibility with Firefox 3.6+Test and Report Add-on Compatibility in Firefox TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional 15 Great Illustrations by Chow Hon Lam Easily Sync Files & Folders with Friends & Family Amazon Free Kindle for PC Download Stretch popurls.com with a Stylish Script (Firefox) OldTvShows.org – Find episodes of Hitchcock, Soaps, Game Shows and more Download Microsoft Office Help tab

    Read the article

  • Python 3: Recursivley find if number is even

    - by pythonhack
    I am writing a program that must find if a number is even or not. It needs to follow this template. I can get it to find if a number is even or not recursively (call function and subtract 2, base case zero), but I am having a hard time following this template, based on how the isEven function is called in the main function. Any help would be greatly appreciated. Write a recursive function called isEven that finds whether a number is even or not: def isEven() #recursivley determine whether number is even or not def main(): number=int(input(“Enter a number : “)) if (isEven(number)): print(“Number is even”) else: print(“Number is not even”) main() Thank you! Appreciate it.

    Read the article

  • MYSQL – Detecting Current Version of MySQL Server Installation

    - by Pinal Dave
    Here is one of the most popular questions which I receive which is related to MySQL installation. The question is how do I know which version of the MySQL I have installed on my server. Here is the simple trick which works all the time. Connect to your MySQL engine with the help of Command Prompt or MySQL Workbench. When you execute the following command it will give us all the necessary information related to MySQL Version. SHOW VARIABLES LIKE "%version%"; Here is the screenshot of the result which I receive when I ran above command on my Test Server. Reference : Pinal Dave (http://blog.SQLAuthority.com) Filed under: MySQL, PostADay, SQL, SQL Authority, SQL Query, SQL Tips and Tricks, T SQL

    Read the article

  • "initialization error: class file has wrong version" message in JDeveloper 10.1.2.x

    - by [email protected]
    The "initialization error: class file has wrong version" has become a somewhat recurrent error message thrown by JDeveloper 10.1.2.x as newer JDKs have been released in the last years. Note that JDeveloper 10.1.2 was developed to run with JDK 1.4.2. The reasons for this error message to be thrown include: A JDK version higher than 1.4.2 is being used and some unexpected incompatibility conflicts can occur because of that Some of the libraries used on the workspace and/or project were compiled with newer JDK version So, it is strongly recommended to use newer JDeveloper versions (10.1.3 - 11g) for newer JDKs. JDeveloper 10.1.2 will be desupported in December 2010 (or later depending on the support contract). Further information about this can be seen at http://www.oracle.com/support/library/brochure/lifetime-support-middleware.pdf

    Read the article

  • Installing a downgraded version of Firefox 16 from PPA

    - by Mikko Ohtamaa
    I'd like to fetch and install old FF16 instead of FF17 on Ubuntu 10.04 LTS server. Currently FF17 is default. FF17 is incompatible with Selenium 2.26 http://stackoverflow.com/questions/13600247/unable-to-run-selenium-suite-on-firefox-17 How one can install an old version of Firefox with apt-get? Can one pindown this version so that it is not automatically updated? Also if there exists a static FF16 installation available it is a solution. apt-cache policy firefox firefox: Installed: 17.0.1+build1-0ubuntu0.10.04.1 Candidate: 17.0.1+build1-0ubuntu0.10.04.1 Version table: *** 17.0.1+build1-0ubuntu0.10.04.1 0 500 http://dk.archive.ubuntu.com/ubuntu/ lucid-updates/main Packages 500 http://security.ubuntu.com/ubuntu/ lucid-security/main Packages 100 /var/lib/dpkg/status 3.6.3+nobinonly-0ubuntu4 0 500 http://dk.archive.ubuntu.com/ubuntu/ lucid/main Packages

    Read the article

  • Drupal : le CMS open-source sortira en version hébergée en 2010 pour concurrencer WordPress, Google

    Le CMS open-source Drupal sortira en version hébergée Courant 2010 pour concurrence WordPress, Google Sites et Microsoft CMS Acquia, la société qui édite Drupal, vient d'annoncer qu'une version hébergée de son célèbre CMS open-source en PHP ? qui sert par exemple à concevoir le site de la NASA ? serait lancée vers le milieu de l'année. Baptisée Drupal Garden, cette version est actuellement en beta-test privé. Elle sera destinée à concurrencer WordPress, actuel leader sur le marché, et à démocratiser l'outil jusqu'ici assez peu connu du grand public. Drupal a en effet souvent été critiqué pour sa complexité. Le CMS propose effectivement un grand nombre de modules comp...

    Read the article

  • How To Create a Portable USB Version of Microsoft Office Starter 2010

    - by Taylor Gibb
    Microsoft Office 2010 Starter edition is a free, ad-supported version of Office 2010 meant to be included on new PCs. It only includes Word and Excel with a subset of features—but it does let you make a portable version. Here’s how to do it. Note: The download link provided in the following article is not exactly a “Microsoft Approved” link and may stop working at any time. Still, the Starter version of Office is meant to be ad-supported freeware, and they haven’t pulled the download despite widespread use of it online. How to See What Web Sites Your Computer is Secretly Connecting To HTG Explains: When Do You Need to Update Your Drivers? How to Make the Kindle Fire Silk Browser *Actually* Fast!

    Read the article

  • Change the Integrated Weblogic Port number

    - by pavan.pvj
    There came a situation where I wanted to work with two JDevelopers simultaneously and start two different applications in two JDEVs. (Both of them have to in separate installation location, else it will create a problem because of system directory).Now, when we want to start WLS in JDEV, only the first one will be started and the other one fails with an exception of port conflict. Until few days back, $1million dollar question was how to change the integrated WLS port number?So, heres the answer after some R&D. In the view menu, click on "Application Server Navigator". Right click on Integrated Weblogic server.1) If it is the first time that you are trying to start the server, then there is a menu "Create Default Domain". If you click on this, a window will be displayed where it asks for the preferred port number. Change it here.2) If the domain is already created, then click on Properties and change the preferred port number.Again, if you want to change the port before starting JDEV from the file system, then goto $JDEV_USER_HOME/systemxxx/o.j2ee and open the file adrs-instances.xml and change the http-port in the startup-preferences:<hash n="startup-preferences">   <value n="http-port" v="7111"/></hash>Note 1: adrs-instances.xml will be created ONLY after you create the default domain.Note 2: systemxxx - refers to system.<JDEV version> like system.11.1.1.3.56.59 for PS2.Note 3: $JDEV_USER_HOME - in windows - would be C:\Documents and Settings\[user_name]\Application Data\JDeveloper"Now, you can run multiple Integrated WLS simultaneously. But please be aware that running more than one WLS server will degrade system performance.

    Read the article

  • Version control and personal configuration file

    - by Erel Segal Halevi
    Our project uses a user-specific configuration file. This file is currently not in version control, since it is different for each user. The problem is, whenever a developer adds a new module that requires configuration, or changes the name of an existing modules, the other developers get errors because their private configuration files are not updated. To solve the problem, we thought of working with two configuration files: a default/global configuration file that will be in version control and will be updated regularly by each developer that adds a new module, and a private configuration file that will be kept out of version control and will contain only the user-specific changes. However, this still seems like an ad-hoc solution. Can you propose a better solution? What do the professionals do?

    Read the article

  • Firefox : abandon du développement de la version 64 bits pour Windows, trop buggée pour Mozilla

    Firefox : abandon du développement de la version 64 bits Sous Windows, trop buggée pour Mozilla Un des responsables de la Fondation Mozilla en charge de « l'engineering » - Benjamin Smedberg - vient d'appeler à mettre fin au développement de la version 64 bits de Firefox pour Windows. La raison ? Cette déclinaison serait une « source continue d'incompréhension et de frustration » pour les utilisateurs et la communauté. Incompréhension parce que les extensions ne sont que rarement compatibles avec cette version. Frustration, parce que le navigateur serait truffé de bugs inextricables et non corrigés (ce qui, d'après Benjamin Smedberg, ferait que ses utilisateu...

    Read the article

  • Can I remove the latest ubuntu version without having to reinstall the old version?

    - by Emily
    I was using the 2.6 kernels with no problems, but when I updated to the 3.0 kernel, my bootup failed. I can manually boot with ctrl+alt+f1 startx and my login, but admittedly, i googled this and have no idea what I'm really doing. I have been trying to figure out how to go back to the old version, and eventually figured out the grub menu--i booted from all three 2.6 (.8, .10, and .11) editions of the previous version of ubuntu but they all had the same error as the 3.0 kernal. I can get logged in manually once the boot fails, but when i get to my desktop, wireless is not responsive and will not connect, and portable hard drives do not mount and/or are unresponsive. the previous version worked perfectly. I use an asus netbook. it's an eee pc. i don't have two OSs on it. i had to go to another computer to get to the forum... If the solution is simple, i just don't know what it is.

    Read the article

  • Why fork a library for your own application?

    - by Mr. Shickadance
    Why should a programmer ever fork a library for inclusion in a widely used application? I ask this question because I was reading an article about why Chromium isn't packaged for many Linux distros like Fedora. Apparently its largely due to the fact that Google has forked a number of libraries, modified them, and included them in Chromium. This has driven up the complexity of packaging releases. There are a number of reasons why this can be a bad thing, but how strong a case can you actually make for doing so in a large widely used application such as Chromium? The original article: http://ostatic.com/blog/making-projects-easier-to-package-why-chromium-isnt-in-fedora Isn't it usually worth the effort to make slight modifications to your own program in order to use a popular and well developed library?

    Read the article

  • mismatch of version of libkdcraw20 and libkdcraw-data

    - by naveen jankar
    I'm using Ubuntu 12.04 LTS. When I'm installlin digiKam, I'm getting a mismatch in the versions of libkdcraw20 and libkdcraw-data wanted by it and that available in the repositories. It wants version 4.8.5-0ubuntu0.2 (or in other words that is the latest version according to synaptic) but the available one is 4.8.5-0ubuntu0.3 in both cases. Is there a work-around? Or how do I request the Ubuntu managers to rectify this? addenda On Synaptic i selected digikam to be installed. it downloaded all the dependencies but the 2 in question were not found - the message it gave "W: Failed to fetch security.ubuntu.com/ubuntu/pool/main/libk/libkdcraw/… 404 Not Found [IP: 91.189.91.13 80]". I google-searched the 2 files in the repositories to find that the version available there is ubuntu0.3 instead of ubuntu0.2.

    Read the article

  • Sortie de la version 1.5 de JRuby avec une amélioration du support sous Windows

    Bonjour, La semaine dernière est sortie la version 1.5 de JRuby, version à laquelle ont contribué pas moins de 30 développeurs Open Source. Parmi les 4 core developpers, 3 font partie de la société Engine Yard. Les avancées principales pour cette version sont :Meilleure intégration avec les librairies Java (gestion mémoire et CPU plus efficace) Amélioration de la compatibilité avec Ruby (Ruby 1.8.7) Amélioration du support pour Windows (les nombreux problèmes qui rendait son utilisation sous Windows compliquée ont été traités) Pour les développeurs Java, il est également à noter de meilleures intégration avec Ant et Maven. Qui utilise régulièrement JRuby, et dans quel cadre ?

    Read the article

  • Unified Communications Suite Ships New Version

    - by joesciallo
    We shipped the latest version (7.0.5.0.0) of Unified Communications Suite. The following information should get you started: Get the Software New Features Release Notes Some Changes for 7.0.5.0.0 Convergence: Version 3.0.0.0.0 enables you to use the add-on framework to add third-party services to the Convergence UI. These services include: Advertising Click-to-call service Multinetwork IM SMS (both one-way and two-way) Social media applications (Facebook, Twitter, and Flickr) Video and voice calling capability For more information, see Overview of Add-on Services in Convergence. Calendar Server: Version 7.0.4.14.0 provides a number of security enhancements, including supporting the SSL protocol for all front-end and back-end communications, and the ability to list hosts that are allowed to send iSchedule POST requests. For more information, see Securing Communications to Calendar Server Back Ends. New Platform Support: Oracle GlassFish Server 3, Oracle Solaris 11, and Oracle Enterprise Linux 6.x are supported in this release of Communications Suite.

    Read the article

  • Choice of Operating System Version for Azure Roles

    - by kaleidoscope
    Customers can now choose when their applications receive new operating system updates and patches by selecting which version of the operating system their applications will run on in Windows Azure.  Right now there is only one available operating system version (released on December 17th, 2009), but new builds with the latest updates and patches will be released regularly.  This new feature allows developers to test their applications when new patches come out before upgrading their production deployments. To select an operating system version for your application, add the new osVersion attribute to your service configuration file.  The full list of available operating system versions is maintained in the Configuring Operating System Versions topic in the Windows Azure MSDN documentation.   Sarang, K

    Read the article

  • Microsoft dévoile la version CTP de Dryad et DryadLINQ pour le développement parallèle et distribué

    Microsoft dévoile la version CTP de Dryad et DryadLINQ Pour le développement parallèle et distribué Microsoft vient de publier la version CTP de ses environnements de calculs parallèles et distribués qui seront commercialisés dans les semaines à venir, Dryad et DryadLINQ. Dryad est un moteur de calcul haute performance pour des calculs distribués, conçu pour simplifier la mise en oeuvre d'applications distribuées. DryadLINQ, lui, permet aux développeurs d'implémenter des applications Dryad en code managé à l'aide d'une version étendue du modèle de programmation LINQ. A la base, la technologie Dryad était un projet de recherche de Microsoft pour l'exécution des donnée...

    Read the article

  • Go passe en version 1.0, le langage de Google est prêt pour être utilisé en production

    Google vient d'annoncer que son langage open source Go était disponible en version 1.0n ce qui marque une importante étape dans l'évolution de ce langage. Rappelons que Go est un langage compilé permettant de simplifier le développement d'applications concurrentes. Il est destiné notamment à la programmation système. Le passage de Go à version 1.0 suppose que le langage soit prêt pour être utilisé en environnement de production et que tout programme créé avec cette version puisse être compilé et exécuté sans modification de code avec les versions suivantes. Toutes les applications s'appuyant sur les versions précédentes doivent être exécutées avec un programme GoFix qui corrigera les problèmes de compatibilité. Avec cette ...

    Read the article

< Previous Page | 17 18 19 20 21 22 23 24 25 26 27 28  | Next Page >