Search Results

Search found 6343 results on 254 pages for 'dll injection'.

Page 211/254 | < Previous Page | 207 208 209 210 211 212 213 214 215 216 217 218  | Next Page >

  • Best practice for autoupdates

    - by ravi
    For desktop based applications, what are best practices to perform auto updates? Currently, we download all files, then copy and register (if com dll) to their respective directories. I looked at Google Chrome update method. It seems that it first downloads a zipped file into a directory, and then unzips all the files. Also, they have a setup application which seems to be used to do the update. Additionally, they create a directory mapped to update version like 1.0.154.43, but they keep the old version's directory.

    Read the article

  • In .NET, How to obtain the target of a symbolic link (or Reparse Point)?

    - by Cheeso
    In .NET, I think I can determine if a file is a symbolic link by calling System.IO.File.GetAttributes(), and checking for the ReparsePoint bit. like so: var a = System.IO.File.GetAttributes(fileName); if ((a & FileAttributes.ReparsePoint) != 0) { // it's a symlink } How can I obtain the target of the symbolic link, in this case? ps: I know how to create a symbolic link. It requires P/Invoke: [Interop.DllImport("kernel32.dll", EntryPoint="CreateSymbolicLinkW", CharSet=Interop.CharSet.Unicode)] public static extern int CreateSymbolicLink(string lpSymlinkFileName, string lpTargetFileName, int dwFlags);

    Read the article

  • How to find dynamically loaded modules (the static ones) programatically in windows

    - by Ryan Rohrer
    I'm trying to port the unix utility ldd to windows, because dependency walker and cygcheck don't quite give me the usage I'm looking for. (also for the learning experience) Ive been looking all over MSDN, for a windows API that lists dll dependencies of an executable, or even the storage format in the complied exe (just to filter it out), but I've been unable to find anything. If anyone knows what API call windows uses for listing modules to load, or what patterns I can search for in an executable to find modules to load, please help me out :) thanks! -note: I'm not looking to profile for dynamic modules, just list the ones that are required at runtime

    Read the article

  • Upgrade to 4.0 Framework, then downgraded, now can't find Linq namespace?

    - by CubanX
    I just upgraded from VS2008 to VS2010. In the process, I allowed it to upgrade my DLL's to 4.0. I've decided that wasn't a good idea and now I've rolled back. It all works fine in VS2010, but when it hits my CI server (CruiseControl.Net), I get an error of: The type or namespace name 'Linq' does not exist in the namespace 'System' (are you missing an assembly reference? 3.5 is on the server, and other projects that use 3.5 build fine, so I don't think it's a framework issue. Anyone have any hints?

    Read the article

  • Howto take a glimpse into mscorlib?

    - by panny
    Hi all! I want to read data into RSAParameters structure ( RSAParameters ) and did check twice, that the data is correct. But still, I get an error "invalid data" exception for this: bei System.Security.Cryptography.CryptographicException.ThrowCryptogaphicException(Int32 hr) bei System.Security.Cryptography.Utils._ImportKey(SafeProvHandle hCSP, Int32 keyNumber, CspProviderFlags flags, Object cspObject, SafeKeyHandle& hKey) bei System.Security.Cryptography.RSACryptoServiceProvider.ImportParameters(RSAParameters parameters) How can I take a look into the source code to check why _ImportKeys is throwing an exception? I have no experience with .dll 'decryption'..are there any symbols to reference somewhere for visual studio 8.0? Thank you.

    Read the article

  • How to get information about a Windows executable (.exe) using C++

    - by ereOn
    Hi, I have to create a software that will scan several directories and extracts information about the executables found. I need to do two things: Determine if a given file is an executable (.exe, .dll, and so on) - Checking the extension is probably not good enough. Get the information about this executable (the company name, the product name, and so on). I never did this before and thus am not aware if there is a Windows API (or lightweight C/C++ library) to do that or if it is even possible. I guess it is, because explorer.exe does it. Do you guys know anything that could point me in the right direction ? Thank you very much for your help.

    Read the article

  • LNK2005: delete already defined error in VC++

    - by user333422
    Hi, I asked this question earlier as well: http://stackoverflow.com/questions/2773168/lnk2005-delete-already-defined-error-in-vc The answer I got was that I should be using dynamic version of DLLs. I did that and it compiled fine. Now, but when I gave the exe to one of my colleagues to run, they told me - they can't run it as it requires some shared dll, so they need a static one. When I try to do static build then I get the error as mentioned in my previous link. Do, I need to provide some other file as well with exe. I have got .lib file as well in the build directory. Shall I provide taht one as well? I can run it fine on my m/c in whichever directory I put it. Any help is much appreciated as I am really stuck. Thanks in advance, Suchita

    Read the article

  • Reading Connection String from a class Library

    - by devnet247
    Hi all I have a .net class library 2.0 with an app.config with a connectionString section. I have 01 Method that this class library exposes " string GetConnectionString(string name) However even though the app.config in this class library has 3 connstrings it does not read this config.exe.How can I make it read the app.config that resides withing this dll? Again, Usually you will have a web or windows app with a config and it will all work. Mine is a special case I need to read the connectionstring within this class library. How can I do it? thanks a lot

    Read the article

  • Windows development: x86 to x64 transition

    - by Kerido
    Hi everybody. Are there any guidelines how to transit to x64 with as little pain as possible? Suppose, I have a windows native x86 executable written in C++. The EXE works fine by itself, but there is also DLL that is hosted by both, the former EXE and an outside x64 process. With setup like this, what parts would I need to rewrite? I would appreciate a more general answer or maybe a link to a reference where some theoretical background is given. Thanks

    Read the article

  • Fastmm4 and leaking handles...

    - by JD
    Hi to all, I have just used FastMM4 to detect leaks. I did not realise our application was using a DLL which was leaking event handles and so I fixed any leaks reported by FastMM4 but not the handles as it was not reported. My questions are, would have FastMM4 have reported the leaking event handles? Would this require me to rebuild the dlls with FastMM4 included? I also heard someone mention ShareMM, do I need to add that? I am using Delphi2007, which I think is using the borland memory manager and if so, should I replace it with the fastMM4 one? What are the steps to do that? Sorry for asking so many questions, I am looking at delphi after a few years of doing .net development. JD.

    Read the article

  • Self-contained python installation with executable tools included (pip, orbited, etc)

    - by Tristan
    I'm trying deploy a Python application on Windows as a folder that includes a full python 2.6 folder. I don't need/want a fancy solution like py2exe, I'm just trying to automate deployment of a web application. So long as I include python26.dll and set the PYTHONHOME correctly, things seem to work if I just include the Python26 folder in its entirety. However a number of the Python26/Script files don't work. For instance, pip.exe, orbited.exe, and morbid.exe all do nothing (complete with no output) when I try to run them on a system that doesn't have a real Python26 installation. I've run out of ideas. Suggestions?

    Read the article

  • Nice RSSFeed Control

    - by Kovu
    Hi, I develope an application in C#.Net 2.0, Windows. The App has a RSS Feed Reader for specific sites (to collect the biggest news). I found a very nice DLL for this in which I can very easy read the RSS. But my problem is the design, I tried a lot, how to display easy, quick and nice, but it sucks like hell, I tried nerly every control in the toolbox and fill it with the RSS Feeds and it looks ugly. So knows anybody a control to display RSS feeds nicly? I know its an copy, but no one answers there.

    Read the article

  • C#:Saving image to folder

    - by Meko
    HI. I know this is simple question but when I use FirstPersonTestImage.Save(IIdComboBox.Text + "-" + i + ".jpg"); it works and saves file to folder where is the .exe file . But I want to save it to specific folder like /photo/IO-66/ and tryed to use String StudentPath = PhotoPath + IGroupNoComboBox.Text + "/" + IIdComboBox.Text + "/" + IIdComboBox.Text + "-" + i + ".jpg"; FirstPersonTestImage.Save(StudentPath); BUt it gives An unhandled exception of type 'System.Runtime.InteropServices.ExternalException' occurred in System.Drawing.dll How can I solve this problem? Is is about folder path ? or using "/" ? EDIT Here My code for creating and checking existing or not folder if (!System.IO.Directory.Exists(PhotoPath + "/" + IGroupNoComboBox.Text.ToString().Trim())) { Directory.CreateDirectory(PhotoPath + "/" + IGroupNoComboBox.Text.ToString().Trim()); } if (!System.IO.Directory.Exists(PhotoPath + "/" + IGroupNoComboBox.Text.ToString().Trim()+ "/" + IIdComboBox.Text.ToString().Trim() + "/")) { Directory.CreateDirectory(PhotoPath + "/" + IGroupNoComboBox.Text.ToString().Trim()+"/" + IIdComboBox.Text.ToString().Trim() + "/"); }

    Read the article

  • How do you make a WiX project build when dependent files have changes?

    - by Scott Langham
    Hi, I've adopted a Visual Studio solution that contains a number WiX projects. We build the solution from an MsBuild script to generate the product's installer msi. The problem I'm experiencing is that if I build (and don't rebuild), even if exe's and dll's get updated that need to be put in the installer, the WiX build system doesn't seem to detect this and skips building the installer as it thinks it's already up to date. How do I work out what the dependencies are that are needed to build a WiX project, and how do I tell the Wix build system to watch out for them changing so it knows to build instead of skip?

    Read the article

  • Assembly Resolver ignores PrivateBinPath

    - by user472875
    I have an assembly I would like to load from a sub-folder of the appbase. I set that sub-folder in the PrivateBinPath during AppDomain creation. The issue is that I have another version of the same DLL in the appbase. From the way it looks, the resolver detects the wrong version first, says that there is a mismatch and stops. As a result the correct version (located in the sub-folder) never gets loaded. I have tested this by removing those DLLs in the appbase and it fixed the problem. Is there any way to force the search even if the wrong version is found?

    Read the article

  • On which Windows versions and configurations does my C++ app run?

    - by saas
    I've built a C++ application using MSVC 2010, default compile settings (note: Using "Multithreaded" instead of "Multithreaded DLL" to avoid the Microsoft C++ runtime being needed). I used only the STL and a few, old functions from the Win32 API (Windows.h). Where will my app run? (98-7?) Can the be any differences on how my app works on different PCs? As said: It's only a simple console app. I'd be glad if you could add some additional information if you have it!

    Read the article

  • Potential Django Bug In QuerySet.query?

    - by Mike
    Disclaimer: I'm still learning Django, so I might be missing something here, but I can't see what it would be... I'm running Python 2.6.1 and Django 1.2.1. (InteractiveConsole) >>> from myproject.myapp.models import * >>> qs = Identifier.objects.filter(Q(key="a") | Q(key="b")) >>> print qs.query SELECT `app_identifier`.`id`, `app_identifier`.`user_id`, `app_identifier`.`key`, `app_identifier`.`value` FROM `app_identifier` WHERE (`app_identifier`.`key` = a OR `app_identifier`.`key` = b ) >>> Notice that it doesn't put quotes around "a" or "b"! Now, I've determined that the query executes fine. So, in reality, it must be doing so. But, it's pretty annoying that printing out the query prints it wrong. Especially if I did something like this... >>> qs = Identifier.objects.filter(Q(key=") AND") | Q(key="\"x\"); DROP TABLE `app_identifier`")) >>> print qs.query SELECT `app_identifier`.`id`, `app_identifier`.`user_id`, `app_identifier`.`key`, `app_identifier`.`value` FROM `app_identifier` WHERE (`app_identifier`.`key` = ) AND OR `app_identifier`.`key` = "x"); DROP TABLE `app_identifier` ) >>> Which, as you can see, not only creates completely malformed SQL code, but also has the seeds of a SQL injection attack. Now, obviously this wouldn't actually work, for quite a number of reasons (1. The syntax is all wrong, intentionally, to show the oddity of Django's behavior. 2. Django won't actually execute the query like this, it will actually put quotes and slashes and all that in there like it's supposed to). But, this really makes debugging confusing, and it makes me wonder if something's gone wrong with my Django installation. Does this happen for you? If so/not, what version of Python and Django do you have? Any thoughts?

    Read the article

  • VS2010 patch: why it's take so much time to install it? [closed]

    - by Mendy
    Visual Studio 2010 RC has a few of patches release. For more information about them take a look here. What I'm expect from patch program, is to replace a few dll's of the program to a new fixed version of them. But when I run each of this 3 patches, they take a lot of time (5 minutes each), and you think that the program was frozen because the progress bar stay on the begging. This is question may not be so important, but it really interesting me to know, why this happens? It's really confusing to see that each VS2010 (or Microsoft in general) is frozen to 4-5 minutes.

    Read the article

  • .net equivalent for php preg_replace

    - by Hath
    What is the c#.net equivalent for php's preg_replace function? php code is like this: const ALLOW_VALUES = '[^a-z0-9àáâäèéêëìíîïòóôöùûwýÿyÁÂÄÈÉÊËÌÎÏÒÓÔÖÙÛÜWYÝ]'; public function streetTownHash($data, $hashCheck = false, $updateRecord = false) { foreach($data as $key=>$value){ try{ $value = mb_convert_case($value, MB_CASE_LOWER, "UTF-8"); } catch(Exception $e) { echo "Requires extension=php_mbstring.dll enabled ! - $e"; } $valueConcat .= preg_replace('/'.self::ALLOW_VALUES.'/','',$value); # Remove punctuation etc } $streetTownHash = sha1($valueConcat); .... this is as far as i've got but not sure about it.. private SHA1 hash = SHA1.Create(); private string hashAllowed = "[^a-z0-9àáâäèéêëìíîïòóôöùûwýÿyÁÂÄÈÉÊËÌÎÏÒÓÔÖÙÛÜWYÝ]"; public string HashString(string value) { value = // = regex not sure this part var bytes = ASCIIEncoding.UTF8.GetBytes(value); var hashed = hash.ComputeHash(bytes); return ASCIIEncoding.UTF8.GetString(hashed); }

    Read the article

  • how to execute a .exe program by php script

    - by user347262
    hello I want to execute a .exe file on my Apache server using a php script. the procedure is as follow: 1- user comes, fills a html form 2- it goses to a php script 3- php script executes the name.exe file 4- php prints the output of the name.exe file on the page. I execute the name.exe normally from windows like this: run--> cmd--> D:\name [command] the name.exe needs to communicate with other files like libraries in the same directory. the complete comand in cmd at windows is like this: D:\name library.dll [input from user] then program executes and prints some results in cmd window. I actually want to run this program on my server form my clients. I dont know how, but I now there is a way to do this. another related questoin is that, is there any shell that i can install on Linux server and execute name.exe in it? thanks in advanced, John.

    Read the article

  • How to authenticate a user using SQL

    - by Tom
    I have an DLL which is constantly connected to a SQL Server instance. The server itself is connected with "admin" permissions, but "normal" users should be able to access the server with their own username and password. The server would still be connected a "admin". I just want to check if the user can access the database. Is there a way to authenticate the user using a SQL query? It would of course be possible to add a encrypted "password" column to a database table for users, but I would prefer not having to do that.

    Read the article

  • need help using 2 mfc projects in one solution

    - by adir
    hi, ive created the first project as mfc application and i have tried to enter the solution another project which created as mfc dll. when i running program the gui from the first solution(demodlg) is shows up. and i want that in a prss of a button in the gui the second gui(CAnalyzerDialog) will show up. i've tried a lot of options and i cant get it done right. the last option ive tried is this code : CAnalyzerDialog dlg; dlg.Create(CAnalyzerDialog::IDD); please help. thank you for your time

    Read the article

  • Best practices for packaging resources (jpg's, sound, video) in an iPhone app?

    - by Mel
    I'm a newb iPhone developer writing an app that has several large JPGs and sound files. Everything works ok if I drag these non-code resources into my project. But I am wondering if this is the right way to package my app. In Windows development, I would create a "resource DLL" that keeps the .exe size small. What is the equivalent for iPhone? I think I should be creating a "bundle" - can someone please give me some pointers to using these and how to link them into my main project? Thanks!

    Read the article

  • Project Reference added to one of the projects in the same solution appears broken in another solution

    - by CSharpLearner
    I have couple of solutions. In the first solution I have many projects. One of the project named 'A' has a project reference of another project 'B' of the same solution. In second solution, the project 'A' is added but not the project 'B'. Both the solutions build successfully. However, in second solution, reference of B added in the project A, appears broken. Why? Now, in first solution, instead of adding Project reference of B into A, i simply add a 'file reference' of B's DLL (which is copied at the common output directory created for all the projects) into A. Now the reference appears broken in both the solution even though both the solutions are built successfully. May I know what should I do when I have such a scenario?

    Read the article

  • Multiple System.Web.Extensions assembly in same project?

    - by CL4NCY
    Hi, I'm having trouble moving a website from one server to another. It seems to be a problem loading multiple versions of System.Web.Extensions. The code uses version 3.5 in most places but a third party control appears to be needing version 1.0.6. I didn't think this was possible but it appears to be working in it's current situation. Is there a way I can use the GAC version of System.Web.Extensions for the site but import a dll of version 1.0.6 just for these controls?

    Read the article

< Previous Page | 207 208 209 210 211 212 213 214 215 216 217 218  | Next Page >