  • Netscaler - Involving Response Body Replacement with GeoIP Implementation

    - by MrGoodbyte
    I have a Netscaler (10000) NS9.3: Build 52.3.cl There is a document contains a short tutorial about GeoIP database implementation at http://support.citrix.com/article/CTX130701 I have added location database by following this tutorial successfully but instead of dropping connections I need to replace a string in content body. To do that, I created a rewrite action with those parameters. * Name: ns_country_replacement_action * Type: REPLACE_ALL * Target Expression: HTTP.RES.BODY(50000) * Replacement Text: HTTP.RES.HEADER("international") * Pattern: \{\/\*COUNTRY_NAME\*\/\} To insert header called "international", I try to create another rewrite action with those parameters. I'll add this one's policy prior. * Name: ns_country_injection_action * Type: INSERT_HTTP_HEADER * Header Name: international * Header Value: CLIENT.IP.SRC.MATCHES_LOCATION("*.US.*.*.*.*").NOT When I click on create button, it says; Compound expression syntax error, [.*.*").NOT^, 50] I'm not sure but I think that two things might cause this error. The expression I use for MATCHES_LOCATION is wrong but I use same expression in the tutorial. MATCHES_LOCATION().NOT returns BOOLEAN but the field expects STRING. How can I get this work? Do I use right tools to accomplish what I need to do? Thank you. -Umut

    Read the article

  • Experience with AMCC 3ware 9650se raid cards? Ours seems dead

    - by antiduh
    We have a 8-port 3ware 9650se raid card for our main disk array. We had to bring the server down for a pending power outage, and when we turned the machine back on, the raid card never started. This card has been in service for a couple years without problems, and was working up until the shutdown. Now, when we turn the machine on, the bios option rom that normally kicks in before the bootloader doesn't show up, none of the drives start, and when the OS tries to access the device, it just times out. The firmware on it has been upgraded in the past, so it's possible we've hit some sort of firmware bug. We're using it in a Silicon Mechanics R272 machine with gentoo for the OS. The OS eventually boots, but alas, without the card. We've ordered a new one, but I'm worried that if we replace the card it won't recognize the existing array. Has anybody performed a card swap before? Any help would be greatly appreciated. Edit: These are the kernel errors we see: 3ware 9000 Storage Controller device driver for Linux v2.26.02.012. 3w-9xxx 0000:09:00.0: PCI INT A -> GSI 18 (level, low) -> IRQ 18 3w-9xxx 0000:09:00.0: setting latency timer to 64 3w-9xxx: scsi0: ERROR: (0x06:0x000D): PCI Abort: clearing. 3w-9xxx: scsi0: ERROR: (0x06:0x001F): Microcontroller not ready during reset sequence. 3w-9xxx: scsi0: ERROR: (0x06:0x0036): Response queue (large) empty failed during reset sequence. 3w-9xxx 0000:09:00.0: PCI INT A disabled

    Read the article

  • Cacti not working for SNMP data sources

    - by lorenzo-s
    I installed packages cacti and snmpd on a Debian server. I'm able to display common graphs in Cacti (such as memory usage, load average, logged in users, etc) using the data templates listed as Unix. Now I want to replace these graphs with new ones using SNMP data sources, because I see there is also CPU usage and because it's not excluded I have to manage multiple hosts in the future. So, I installed snmpd on the machine and left the snmpd.conf as it is. In Cacti, I created three new data sources from SNMP templates for 127.0.0.1 host: ucd/net - CPU Usage - Nice ucd/net - CPU Usage - System ucd/net - CPU Usage - User Then I created a new graph from template ucd/net - CPU Usage, and select the three data sources in the Graph Item Fields section. Graph is now enabled and running, but empty. No data have been collected. Under Console - Devices my SNMP host is listed as up and running: System:Linux ip-xx-xx-xxx-xxx 3.2.0-23-virtual #36-Ubuntu SMP Tue Apr 10 22:29:03 UTC 2012 x86_64 Uptime: 929267 (0 days, 2 hours, 34 minutes) Hostname: ip-xx-xx-xxx-xxx Location: Sitting on the Dock of the Bay Contact: Me [email protected] In SNMP Options I left all as it is: SNMP Version: Version 1 SNMP Community: public SNMP Timeout: 500 ms Maximum OID's Per Get Request: 10 In Console - Utilities - Cacti Log I have multiple warning (two for each data source) every 5 minutes: 10/29/2012 01:45:01 PM - CMDPHP: Poller[0] Host[2] DS[18] WARNING: Result from SNMP not valid. Partial Result: U 10/29/2012 01:45:01 PM - CMDPHP: Poller[0] WARNING: SNMP Get Timeout for Host:'127.0.0.1', and OID:'.1.3.6.1.4.1.2021.4.15.0' 10/29/2012 01:45:01 PM - CMDPHP: Poller[0] Host[1] DS[9] WARNING: Result from SNMP not valid. Partial Result: U 10/29/2012 01:45:01 PM - CMDPHP: Poller[0] WARNING: SNMP Get Timeout for Host:'127.0.0.1', and OID:'.1.3.6.1.4.1.2021.11.52.0' 10/29/2012 01:40:01 PM - CMDPHP: Poller[0] Host[2] DS[19] WARNING: Result from SNMP not valid. Partial Result: U 10/29/2012 01:40:01 PM - CMDPHP: Poller[0] WARNING: SNMP Get Timeout for Host:'127.0.0.1', and OID:'.1.3.6.1.4.1.2021.4.6.0' [...] I have the feeling I'm missing something, but I cannot get it...

    Read the article

  • solaris zpool SSD cache device "faulted"

    - by John-ZFS
    I am trying to get over these SATA SSD errors - smartctl command failed to read the SATA SSD - SATA is not supported what could be the reason for errors? does this mean that SSD has reached EOL & needs to be replacement? errors: No known data errors pool: zpool1216 state: DEGRADED status: One or more devices are faulted in response to persistent errors. Sufficient replicas exist for the pool to continue functioning in a degraded state. action: Replace the faulted device, or use 'zpool clear' to mark the device repaired. scan: scrub repaired 0 in 0h24m with 0 errors on Fri May 18 14:31:08 2012 config: NAME STATE READ WRITE CKSUM zpool1216 DEGRADED 0 0 0 raidz1-0 ONLINE 0 0 0 c11t10d0 ONLINE 0 0 0 c11t11d0 ONLINE 0 0 0 c11t12d0 ONLINE 0 0 0 c11t13d0 ONLINE 0 0 0 c11t14d0 ONLINE 0 0 0 c11t15d0 ONLINE 0 0 0 c11t16d0 ONLINE 0 0 0 c11t1d0 ONLINE 0 0 0 c11t2d0 ONLINE 0 0 0 c11t3d0 ONLINE 0 0 0 c11t4d0 ONLINE 0 0 0 c11t5d0 ONLINE 0 0 0 c11t6d0 ONLINE 0 0 0 c11t7d0 ONLINE 0 0 0 c11t8d0 ONLINE 0 0 0 c11t9d0 ONLINE 0 0 0 logs c9d0 FAULTED 0 0 0 too many errors cache c10d0 FAULTED 0 17 0 too many errors

    Read the article

  • Windows Server (SBS) 2008 - Telephony service won't start (missing permissions)

    - by Uri
    I am running a SBS 2008 server. It's setup as the domain controller for the network. After a reboot, the Telephony service (and all services that depend on it) refuses to start under the Network Service account. The error given is: Error 1297: A privilege that the service requires to function properly does not exist in the service account configuration. You may use the Services Microsoft Management Console (MMC) snap-in (services.msc) and the Local Security Settings MMC snap-in (secpol.msc) to view the service configuration and the account configuration. This has caused all the network services not to be accessible e.g. terminal services, VPN (RRAS), SQL Server instances. The SSH daemon I have running on the box will accept connections only from localhost, but won't respond on the network. After searching around, the only advice I could find was to grant the Network Service account these permissions: Adjust memory quotas for a process Replace a process level token I set those permissions on both the Default Domain Policy and the Default Domain Controller Policy, but it seemingly had no effect. Most of the services will start if I change them to run under the Local System account, but that didn't make them accessible on the network. I even tried removing the Routing and Remote Access Services feature, rebooting and reinstalling it, but the issue remains. Any ideas?

    Read the article

  • Multiple public IPs through DD-WRT without 1-to-1 NAT

    - by Stephen Touset
    I've done a search here and wasn't able to find anything relevant to my situation. I apologize in advance if I've missed an existing post on the topic. Our ISP has provided us with 6 static IP addresses. We are currently using two of them (plus one for the Comcast-provided router). One of the static addresses routes to our internal network, and the other goes to our VOIP phone system. Unfortunately, the Comcast machine doesn't support QoS, so our VOIP calls have been choppy. We plan to put the Comcast-provided router into bridge mode and replace it with an ASUS RT-N16 running DD-WRT. However, I'm unsure how to set up DD-WRT to function similarly to our existing Comcast router. The Comcast router's WAN IP is the first of our static IP addresses. We did not need to provide an internal LAN IP address — simply connecting machines that use our other public addresses to the LAN ports on the Comcast router is enough for it to route between the connected machines and our internet connection. Is there a way to do a similar setup through the DD-WRT? Thanks in advance.

    Read the article

  • Xbox360 Universal Media Remote - out of sync?

    - by Traveling Tech Guy
    Hi, I have the Universal Media Remote from Microsoft, which was included with my HD-DVD package. I've been using it for over a year to watch videos/DVDs on my Xbox360 and it saved me the hassle of navigating with the game controller (which turns itself off every 5 minutes).All of a sudden (it didn't fall or suffer any severe trauma), it does not communicate with the Xbox anymore: it is on, I replaced batteries several times, but the Xbox does not respond to commands. The TV does - volume, channels, etc. - but I need the Xbox functionality.As far as I can see, there's no way to sync the remote with the Xbox - it lacks that small sync button that the game controllers have.I called Microsoft Support and spoke for an hour to someone who, I guess didn't know what to do at all. Bottom line - since it's been over a year, they won't fix/replace it - I have to get a new one.Before I do (if I do), I need to know if there's anything I can do with the existing remote, and will I have the same problem with a new one (i.e. the problem is with the Xbox itself)? Thanks!

    Read the article

  • script to run sox to combine multiple mono tracks to stereo

    - by Ze'ev
    I have a folder full of .wav audio files. Some are stereo, most are mono splits. The mono split pairs are all named foo bar track.L.wav and foo bar track.R.wav I can use the command line tool sox to combine a mono pair into 1 stereo track like this: sox -M track1.L.wav track1.R.wav track1.Stereo.wav where the first 2 files are the mono pairs, and the third is the output stereo file. This is great, but I'd like to have a script that will automatically find all the mono pairs and combine them into stereo files. I.e., I need it to find all files which have the same name except for the .L. and .R. before the extension, and run sox on them, outputting to a new file with the same name without the L/R suffix. For example, if my folder contains these files: track1.L.wav track2.L.wav track3.L.wav track4.L.wav track1.R.wav track2.R.wav track3.R.wav track4.R.wav track6.wav track7.wav I need to run these commands: sox -M track1.L.wav track1.R.wav track1.Stereo.wav sox -M track2.L.wav track2.R.wav track2.Stereo.wav sox -M track3.L.wav track3.R.wav track3.Stereo.wav sox -M track4.L.wav track4.R.wav track4.Stereo.wav Here's where I am so far: for file in ./*.L.wav; do file2=`echo $file | sed 's_\(.*\).L.wav_\1.R.wav_'`; out=`echo $file | sed 's_\(.*\).L.wav_\1.STEREO.wav_'`; echo $file - $file2 - $out; done That works, but when I replace the echo line with sox -M $file $file2 $out; it doesn't work; spaces in the filenames cause it to fail.

    Read the article

  • Can I attach a VPN firewall to an existing network and have it manage VPN connections?

    - by jules
    I'm quite new to networking and am trying to set up my first VPN connection. The Situation: I have been contracted for some programming at a facility some distance from my location. I would like to be able to set up a simple VPN connection to their network so that I may make adjustments without significant travel. Their Current Network: Six devices (one I need to connect to) plugged into a basic router (Dlink). This router has an internet connection and a static ip address. My Hopeful (questionable) Proposal: I attach a VPN Firewall I happen to own (Netgear FVS318) as device number seven on the client network. I disable routing / DHCP in the Netgear. I forward the appropriate IPSec ports from the Dlink to the Netgear. I then create a VPN connection on my office Windows 7 machine to the remote network. The request is forwarded from the Dlink to the Netgear where the VPN connection is authenticated. I now have a remote-access connection from my office PC to the client's local network. The Question: Will this proposal work? If not, would another possibility be to attach a computer with a VPN server to the client network? Also, as a note: the client has requested I not replace their router or place mine in-between theirs and the internet :( Thanks very much!

    Read the article

  • laptop motherboard "shorts" when connected to adapter

    - by Bash
    Disclaimer: I'm sort of a noob, and this is a long post. Thank you all in advance! summary: completely dead laptop with no signs of life whatsoever (suddenly, for no apparent reason) Here's the deal: Lenovo Y470 (only a few months old with no water or shock damage). It stopped working suddenly (no lights, no sound, even when connecting adapter with or without battery). I tried a different adapter (same electrical rating), but no luck. I disassembled the thing completely, and tried plugging in the adapter and looking for signs of life with all different combinations of components installed (tried all combinations of RAM, CPU, USB power cords, screen, etc plugged in). no luck. Then, I noticed (as I was plugging in the adapter to try for the millionth time) that there was a "spark" for an instant when I first connect the adapter to the power jack. The adapter's LED would then flash (indicating it isn't working or charging). So, I thought the power jack has a short of some sort (due to bad soldering or something). Scanned virtually every single component on the motherboard, and tested the power jack connections with a multimeter. No shorts or damage to anything on the entire motherboard. Now I'm thinking I need to replace the motherboard. But, my actual question: What does this "shorting" when connecting the adapter signify? (btw, the voltage across the power connections and current through it drop to virtually zero when the adapter is connected and "sparks", and they stay that way). The bewildering thing is that there are no damaged components, and the voltage across adapter terminals returns to normal after I disconnect it (so it's not damaged). Please take a look at the pictures (of the motherboard's power connection and nearby components) and see if I'm missing something completely obvious... Links to pictures and laptop and motherboard model: pictures on DropBox Motherboard model: LA-6881P Laptop model: Lenovo IdeaPad Y470

    Read the article

  • If spaces in filenames are possible, why do some of us still avoid using them?

    - by Chris W. Rea
    Somebody I know expressed irritation today regarding those of us who tend not to use spaces in our filenames, e.g. NamingThingsLikeThis.txt -- despite most modern operating systems supporting spaces in filenames. Non-technical people must look at filenames created by geeks and wonder where we learned English. So, what are the reasons that spaces in filenames are avoided or discouraged? The most obvious reason I could think of, and why I typically avoid it, are the extra quotes required on the command line when dealing with such files. Are there any other significant reasons, other than the practice being a vestigial preference? UPDATE: Thanks for all your answers! I'm surprised how popular this was. So, here's a summary: Six Reasons Why Geeks Prefer Filenames Without Spaces In Them It's irritating to put quotes around them when referenced on the command line (or elsewhere.) Some older operating systems didn't used to support them and us old dogs are used to that. Some tools still don't support spaces in filenames at all or very well. (But they should.) It's irritating to escape spaces when used where spaces must be escaped, such as URLs. Certain unenlightened services (e.g. file hosting, webmail) remove or replace spaces anyway! Names without spaces can be shorter, which is sometimes desirable as paths are limited.

    Read the article

  • How does the EFI partition work and can I boot an x86 OS with a bootx64.efi file?

    - by Ian
    I have a Thinkpad X230 laptop and I want to install Linux Mint Debian Edition along side Windows 7 on my GPT formatted SSD with the BIOS in UEFI mode. The problem is that I don't understand how EFI booting works. There seems to be an EFI partition involved with some folders and binary files in it. GRUB 2 seems to be able to make more folders in it (I followed this guide http://www.thinkwiki.org/wiki/UEFI_Firmware), but it appears that the only file that does anything is the bootx64.efi file in the /efi/boot folder of the EFI partition (I am not sure if this is always the case, but it appears to be the case for my laptop http://www.thinkwiki.org/wiki/Category:X220). Here is what I have been able to do: I can install Linux Mint Debian Edition x86 with the BIOS in BIOS mode on my SSD. I can then install grub-efi and follow the guide linked above. The problem is that I don't get a GRUB prompt when I switch the BIOS to UEFI mode. It just boots Windows. It appears that I can either boot from the SSD or something called "Windows Boot Manager". If I replace the bootx64.efi with the file created by GRUB, I can no longer boot directly from the SSD. Booting from "Windows Boot Manager" still works fine. I realize that the guide says to use x64 Linux, but Linux Mint Debian Edition x64 hangs during the install process. I am really confused. What should I do? Can anyone explain how the EFI boot partition works? Can a bootx64.efi boot an x86 OS? Should I just give up with using UEFI? I haven't been able to find very much useful information about using Debian based operating systems with UEFI. Thanks, Ian

    Read the article

  • Dual Xeon Server voltages are low

    - by Mindflux
    I've got a whitebox server running CentOS 5.7. It's a Dual Xeon 5620, 24GB of RAM. The mainboard is a SuperMicro X8DT6-F and the chassis is a SC825TQ-R720LPB. Dual 720W Power supplies. We had a big power outage a couple weeks back that took down everything, I don't have any pre-power outage figures for this server, and the only reason I noticed these is because when I was bringing up the servers I was checking them out with more scrutiny than usual. http://i.imgur.com/rSjiw.png (Image of voltage readings) As you can see, CPU1 DIMM is low, +3.3V is high, 3.3VSB is high, +5v is high, +12v is REAL LOW (out of normal 5% (plus/minus))... and VBAT is off the charts. With my whitebox VAR we've tried the following: Swap out PSU with another server I have with the same PSUs. Try different power cord Update BMC/IPMI firmware in case readings were wrong (They aren't) Update BIOS Try different PDU Try a different outlet and/or circuit Replaced Voltage Regulator Unit At this point, the only thing we haven't done, seemingly is replace the mainboard.. which is what the next step will be unless something else shines some light on the situation. I should mention the system is rock solid otherwise which is a surprise given the 12v voltage is that far off.

    Read the article

  • Red Hat 5.3 on HP Proliant DL380 G5 and failed drive on RAID controller

    - by thinkdreams
    I have a development ERP server here in my office that I assist with support on, and originally the DBA requested a single drive setup for some of the drives on the server. Thus the hardware RAID controller (an HP embedded controller) looks like: c0d0 (2 drive) RAID-1 c0d1 (2 drive) RAID-1 c0d2 (1 drive) No RAID <-- Failed c0d3 (1 drive) No RAID c0d4 (1 drive) No RAID c0d5 (1 drive) No RAID c0d2 has failed. I replaced the drive immediately with a spare using the hot-swap, but the c0d2 continues to mark itself as failed, even when I umount the partition. I'm loathe to reboot the server since I'm concerned about the server coming back up in rescue mode but I'm afraid that's the only way to get the system to re-read the drive. I assumed there was some sort of auto-detection routine for this, but I haven't been able to figure out the proper procedure. I have installed the HP ACU CLI utilties, so I can see the hardware RAID setup. I'd really like to find out what the proper procedure should have been, where I went wrong, and how to correct it now. Obviously this goes without saying I should NOT have listened to the DBA and set the drives up as RAID-1 throughout as was my first instinct. He wasn't worried about data loss, but it sure would have been easier to replace the failed drive. :)

    Read the article

  • update all the servers through one virtual servers using Storage are network virtual machine

    - by Mr.Calm
    Using UBUNTU and Virtal Box by Oracle, and Using this script to start nginx in Virtual Box, and placing it in Virtual box inside~/init.d #!/bin/bash ### BEGIN INIT INFO # Provides: Testinit # Required-Start: # Required-Stop: # Default-Start: 2 3 4 5 # Default-Stop: 0 1 6 # Short-Description: Start daemon at boot time # Description: Enable service provided by daemon. ### END INIT INFO # RETVAL=0; start() { CurrentTime=$(date +%d/%m/%Y"-"%I:%M:%S) ./usr/local/nginx/sbin/nginx echo "Current Time:"$CurrentTime>>/home/server/Desktop/NginxLogs.txt echo "!Starting nginx!" >>/home/server/Desktop/NginxLogs.txt Like this i want to write auto script (setup.sh file) and place that script in all virtual boxes inside my system, for example 8 virtual boxes and in all Virtual boxes NGINX is installed. Now, The thing is i am facing problem when i want change something in setup.sh i have to go to each and every virtual box, or Communicate each Virtual machine through SSH from my main machine. i am thinking to write another script (ex: Update.sh),and inside that script we give one path of file which is saved and recently edited in main machine (ex: DummySetup.sh). as soon as i run that script all the setup.sh files which are saved in each virtual machines should update the change or replace contents with DummySetup.sh's contents. Hope this is possible thing. Help would be appreciated.Thanking you

    Read the article

  • Joining two routers together, but I have no access to the second router, although I know it's IP address and Gateway

    - by JohnnyVegas
    I have temporarily moved into a rented apartment for 4 months, which has wireless. The trouble I am having is that the access points here are wifi only and no RJ45 and I need to use RJ45 to connect some equipment that I am working with. I have purchased an RT-N66U and installed Tomato (shibby ver. 1.28) and successfully replaced the existing access point, but now I want to enable the access point that I have replaced as it links wirelessly to 3 others. Can I plug in a cable from the access point to my RT-N66U and get it to access the internet via my router? I have no access to the existing wireless access point, and don't want to reset it as it's not mine. There is another router situated in the roof somewhere which I also have no access to, but it's supplying my RT-N66U internet and I most definitely have a double-nat, which although isn't the best way of doing things I am limited with what I can do. Any suggestions on routing tables, vlans etc would be helpful, but I have no experience in these fields before - but I know the tomato firmware can cater for this. My router is set to IP 10.0.1.1 and dhcp is 10.0.1.100-200 The wireless access point address was 192.168.1.2 but this was assigned by the router in the roof which has the address 192.168.1.1. There is a cable from this router going to a wall socket which I now have my RT-N66u attached to via the WAN port. I understand it's scruffy and it isn't the way to do things but I have tried to ask for the admin details but as the wireless network is looked after by a third party and nobody knows their details I am stuck with this dilemma. I could buy three wireless access points and replace the existing but this isn't what I want to do, and although I have installed plenty of DD-WRT wireless repeater bridges they simply don't work here for some unknown reason. The phone line here is very noisy too and I don't have the rights to install ADSL in a building that isn't mine, and 3G coverage isn't good enough either. Thanks for your time

    Read the article

  • Is On-The-Fly string replacement possible using GreaseMonkey and Firefox

    - by Gary M. Mugford
    I have looked for means to stop Brightcove videos from autostarting in Firefox and have come to the conclusion it isn't possible without external programming via something like Grease Monkey. However, I'm not proficient in javascript let alone GM. So I thought I'd ask here first whether what I want to do is feasible, or whether it's a fool's errand. What I want to accomplish is have a site specific script executed to replace a string value on the run in that site's code. Specifically, what I am looking for is something GM-style that would do this: if site_domain = 'www.SiteWithAutoPlayVideos.com' then replace_all('<param name="autoStart" value="true" />', '<param name="autoStart" value="false" />'); Having looked through Super User for anything GreaseMonkey that might relate, I see notices that the sandbox GM executes scripts in has to remain separate for security reasons. So, I suspect I might be in for disappointment. BUT if it is accomplishable and somebody here can confirm it, then I will do my best to struggle through the learning curve and get this noisome little problem put to rest. Yes, I have tried Flash Block and FlashDisable in order to attack this issue with no avail. Thanks in advance for your time.

    Read the article

  • F5 Networks iRule/Tcl - Escaping UNICODE 6-character escape sequences so they are processed as and r

    - by openid.malcolmgin.com
    We are trying to get an F5 BIG-IP LTM iRule working properly with SharePoint 2007 in an SSL termination role. This architecture offloads all of the SSL processing to the F5 and the F5 forwards interactive requests/responses to the SharePoint front end servers via HTTP only (over a secure network). For the purposes of this discussion, iRules are parsed by a Tcl interpretation engine on the F5 Networks BIG-IP device. As such, the F5 does two things to traffic passing through it: Redirects any request to port 80 (HTTP) to port 443 (HTTPS) through HTTP 302 redirects and URL rewriting. Rewrites any response to the browser to selectively rewrite URLs embedded within the HTML so that they go to port 443 (HTTPS). This prevents the 302 redirects from breaking DHTML generated by SharePoint. We've got part 1 working fine. The main problem with part 2 is that in the response rewrite because of XML namespaces and other similar issues, not ALL matches for "http:" can be changed to "https:". Some have to remain "http:". Additionally, some of the "http:" URLs are difficult in that they live in SharePoint-generated JavaScript and their slashes (i.e. "/") are actually represented in the HTML by the UNICODE 6-character string, "\u002f". For example, in the case of these tricky ones, the literal string in the outgoing HTML is: http:\u002f\u002fservername.company.com\u002f And should be changed to: https:\u002f\u002fservername.company.com\u002f Currently we can't even figure out how to get a match in a search/replace expression on these UNICODE sequence string literals. It seems that no matter how we slice it, the Tcl interpreter is interpreting the "\u002f" string into the "/" translation before it does anything else. We've tried various combinations of Tcl escaping methods we know about (mainly double-quotes and using an extra "\" to escape the "\" in the UNICODE string) but are looking for more methods, preferably ones that work. Does anyone have any ideas or any pointers to where we can effectively self-educate about this? Thanks very much in advance.

    Read the article

  • Postfix aliases and duplicate e-mails, how to fix?

    - by macke
    I have aliases set up in postfix, such as the following: [email protected]: [email protected], [email protected] ... When an email is sent to [email protected], and any of the recipients in that alias is cc:ed which is quite common (ie: "Reply all"), the e-mail is delivered in duplicates. For instance, if an e-mail is sent to [email protected] and [email protected] is cc:ed, it'll get delivered twice. According to the Postfix FAQ, this is by design as Postfix sends e-mail in parallel without expanding the groups, which makes it faster than sendmail. Now that's all fine and dandy, but is it possible to configure Postfix to actually remove duplicate recipients before sending the e-mail? I've found a lot of posts from people all over the net that has the same problem, but I have yet to find an answer. If this is not possible to do in Postfix, is it possible to do it somewhere on the way? I've tried educating my users, but it's rather futile I'm afraid... I'm running postfix on Mac OS X Server 10.6, amavis is set as content_filter and dovecot is set as mailbox_command. I've tried setting up procmail as a content_filter for smtp delivery (as per the suggestion below), but I can't seem to get it right. For various reasons, I can't replace the standard OS X configuration, meaning postfix, amavis and dovecot stay put. I can however add to it if I wish.

    Read the article

  • Boot loop that I cannot bypass

    - by lonewaft
    Recently, on a laptop that I've used for a while, I had a strange issue where OS files were corrupted (device manager) and Windows 8 was hung after the login screen, so I reinstalled Windows 7 over the existing Windows 8 installation, and it worked for a couple days. Today, when I tried to use my laptop, it was stuck on a boot loop. Right after the BIOS screen, it would show a flashing underscore, then restart the computer, again and again until I removed the battery. I tried booting to a windows 7 install CD, but the same flashing underscore - reboot sequence happened when I tried. I tried moving the boot priority around (HDD first, CD/DVD first, even USB first) but nothing changed. After about an hour of tinkering with it, I listened to the HDD sounds, and it sounded like the HDD was trying to spin up, but failing (whining noise increasing in frequency that stopped and started in sync with the system restarting). I am planning to replace the HDD, but I'm still confused as to why a faulty HDD would stop the laptop from booting to my install DVD (tried it on a different computer, it booted from that CD fine). Anybody here have any idea why this might be happening?

    Read the article

  • ProCurve network expansion

    - by Blue Warrior NFB
    I've hit a bit of a wall with our network scale-out. As it stands right now: We have five ProCurve 2910al switches connected as above, but with 10GbE connections (two CX4, two fiber). This fully populates the central switch above, there will be no more 10GbE Ethernet connections from that device. This group of switches is not stacked (no stack directive). Sometime in the next two or three months I'll need to add a sixth, and I'm not sure how deep of a hole I'm in. Ideally I'd replace the core switch with something more capable and has more 10GbE ports. However, that's a major outage and that requires special scheduling. The two edge switches connected via fiber have dual-port 10GbE cards in them, so I could physically put another switch on the far end of one of those. I don't know how much of a good or bad idea that would be though. Is that too many segments between end-points? Some config-excerpts: Running configuration: ; J9147A Configuration Editor; Created on release #W.14.49 hostname "REDACTED-SW01" time timezone 120 module 1 type J9147A module 2 type J9008A module 3 type J9149A no stack trunk B1 Trk3 Trunk trunk B2 Trk4 Trunk trunk A1 Trk11 Trunk trunk A2 Trk12 Trunk vlan 15 name "VM-MGMT" untagged Trk2,Trk5,Trk7 ip helper-address 10.1.10.4 ip address 10.1.11.1 255.255.255.0 tagged 37-40,Trk3-Trk4,Trk11-Trk12 jumbo ip proxy-arp exit

    Read the article

  • How to compare old CPU to new CPU?

    - by Lasse V. Karlsen
    I hope this question doesn't get closed at once :) I have an old laptop, a Compaq NC4200, which is going its final laps around the track these days. Battery is dead, and everything kinda runs slow. It also has only 1GB of memory, and even though I don't know if it can take more, I probably wouldn't be able to get hold of any that matches without having to special order it. The size, however, has been ideal for my usage pattern, so I'm looking to replace it with a similarly sized laptop, at least in the same size category. However, it's been a while since I tried keeping track of CPUs, so I have a question. The old laptop has a Intel Pentium M 760 1.86GHz processor. One laptop I found online has a Intel Pentium SU4100 1.3GHz dual-core. This type of processor seems to be quite common in the price and size-range I've been looking. What kind of relative performance boost could I expect from the old one to the new one? I am not expecting a "about 7.45x speed", but some indication would be nice. For instance, dual-core tells me it might be akin to 2.6GHz, but I assume I can't simply compare 1.86GHz to 2.6GHz and expect the new one to run about 1.4x as fast, I expect more these days. Or is that unrealistic for this kind of processor? Do I need to up my price range and go for a 2+ GHz processor?

    Read the article

  • Does water damage a fiber optic / cat5 cable

    - by chris
    One of the buildings I support recently had an adventure with a broken fire sprinkler. Lots of water everywhere. One of the "drains" the water used was the vertical risers between network closets. The cable plant in this building has bundles of cat5e as well as conduit with bundles of multimode fiber optic cables. The fiber is standard multi strand plenum rated stuff that terminates in boxes that have the patches to the switches. As far as I can tell, no water got near the ends of the cables (fiber or copper) but the conduit was saturated, and is likely still saturated because there isn't any air flow to dry the cables out. My gut reaction is that while it didn't do the cables any favors, it likely also isn't going to cause any problems. A little more reading / googling around leads me to believe that the water may cause problems down the road. Some pretty pictures so everyone knows what I'm talking about: Fiber conduit: Vertical riser, going down: Vertical riser, going up: Does anyone have any experience with this sort of damage and how to deal with it? Should we just ask the insurance adjuster to add "pull new structured cable" to the list of things to be replaced? And, if the opinion is "replace it because it'll start failing randomly over time" please include links that describe the specific failure modes, so I've got some ammo to use with the adjuster.

    Read the article

  • Startup script for Red5 on Ubuntu 9.04

    - by user49249
    I am creating startup script for Red5 on Ubuntu. Red5 is installed in /opt/red5 Following is a working script on a CentOS Box on which Red5 is running [code] ==========Start init script ========== #!/bin/sh PROG=red5 RED5_HOME=/opt/red5/dist DAEMON=$RED5_HOME/$PROG.sh PIDFILE=/var/run/$PROG.pid # Source function library . /etc/rc.d/init.d/functions [ -r /etc/sysconfig/red5 ] && . /etc/sysconfig/red5 RETVAL=0 case "$1" in start) echo -n $"Starting $PROG: " cd $RED5_HOME $DAEMON >/dev/null 2>/dev/null & RETVAL=$? if [ $RETVAL -eq 0 ]; then echo $! > $PIDFILE touch /var/lock/subsys/$PROG fi [ $RETVAL -eq 0 ] && success $"$PROG startup" || failure $"$PROG startup" echo ;; stop) echo -n $"Shutting down $PROG: " killproc -p $PIDFILE RETVAL=$? echo [ $RETVAL -eq 0 ] && rm -f /var/lock/subsys/$PROG ;; restart) $0 stop $0 start ;; status) status $PROG -p $PIDFILE RETVAL=$? ;; *) echo $"Usage: $0 {start|stop|restart|status}" RETVAL=1 esac exit $RETVAL [/code] What do I need to replace for Ubuntu in the above script. My Red5 is in /opt/red5/ and to start it manually I always do /opt/red5/dist/red5.sh from Ubuntu As I did not find rc.d/functions on Ubuntu on my laptop also /etc/init.d/functions I did not existed. I would like to be able to use them with service as Red hat distributions do. I checked /lib/lsb/init-functions.

    Read the article

  • AMD FX8350 CPU - CoolerMaster Silencio 650 Case - New Water Cooling System

    - by fat_mike
    Lately after a use of 6 months of my AMD FX8350 CPU I'm experiencing high temperatures and loud noise coming from the CPU fan(I set that in order to keep it cooler). I decided to replace the stock fan with a water cooling system in order to keep my CPU quite and cool and add one or two more case fans too. Here is my case's airflow diagram: http://www.coolermaster.com/microsite/silencio_650/Airflow.html My configuration now is: 2x120mm intake front(stock with case) 1x120mm exhaust rear(stock with case) 1 CPU stock I'm planning to buy Corsair Hydro Series H100i(www.corsair.com/en-us/hydro-series-h100i-extreme-performance-liquid-cpu-cooler) and place the radiator in the front of my case(intake) and add an 120mm bottom intake and/or an 140mm top exhaust fan. My CPU lies near the top of the MO. Is it a good practice to have a water-cooling system that takes air in? As you can see here the front of the case is made of aluminum. Can the fresh air go in? Does it even fit? If not, is it wiser to get Corsair Hydro Series H80i (www.corsair.com/en-us/hydro-series-h80i-high-performance-liquid-cpu-cooler) and place the radiator on top of my case(exhaust) and keep the front 2x120mm stock and add one more as intake on bottom. If you have any other idea let me know. Thank you. EDIT: The CPU fan running ~3000rpm and temp is around 40~43C on idle and save energy. When temp is going over 55C when running multiple programs and servers on localhost(tomcat, wamp) rpm is around 5500 and loud! I'm running Win8.1 CPU not overclocked PS: Due to my reputation i couldn't post the links that was necessary. I will edit ASAP.

    Read the article

< Previous Page | 214 215 216 217 218 219 220 221 222 223 224 225  | Next Page >